Printing recorder with text printing and 24-character LED dot-matrix display. Brief description. Overview of functions. Features of the Type

Size: px
Start display at page:

Download "Printing recorder with text printing and 24-character LED dot-matrix display. Brief description. Overview of functions. Features of the Type"

Transcription

1 JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, Fulda, Germany Postal address: Fulda, Germany Phone: Fax: Internet: JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: Fax: Internet: JUMO Process Control, Inc. 8 Technology Boulevard Canastota, NY 13031, USA Phone: JUMO JUMO Fax: info@jumo.us Internet: Data Sheet Page 1/12 Printing recorder with text printing and 24-character LED dot-matrix display Brief description The LOGOPRINT recorder family consists of two printing recorders, the LOGOPRINT 500 and the LOGOPRINT 500 junior. LOGOPRINT 500 () The printing recorder is equipped with 3 or (optionally) 6 measurement inputs, which are electrically isolated from one another. The evaluation of the measurement traces of the printing recorder can be assisted by extensive text printing. The recorder can be programmed either by using the 8 keys on the front of the instrument or through a PC setup program. Thermocouples, resistance thermometers, resistance transmitters, potentiometers, voltages or currents (standard signals) are possible as input signals. The appropriate linearizations are carried out automatically, but can also be adapted to customer-specific linearizations with the help of the PC setup program. Further outstanding features of the LOGOPRINT 500, which are already included in the basic version, are four open-collector outputs for signaling infringements of limits and faults, eight event traces, as well as peak value recording. The color assignments (measurement traces and texts) are freely programmable via the PC setup program, which is available as an accessory. LOGOPRINT 500 junior (Type ) This recorder is equipped with 6 measurement inputs, which are electrically isolated from one another. It can also support the evaluation of the measurement traces with printed text (limited). Programming is only possible via the keys. Voltages and currents (standard signals) are possible as input signals. There are no open-collector outputs, no event traces, no peak value recording and no extra codes. Overview of functions Analog inputs (configurable and isolated) Type or 6 inputs for: - thermocouples - resistance thermometers - resistance transmitters - potentiometers - voltage and current 6 inputs for: - voltage - current 8 logic inputs available as extra code not available Outputs - 4 open-collector outputs available as extra code: - interface for 8 relay outputs - supply for 2-wire transmitter not available Recording Setup interface RS422/RS485 interface - measurement traces - text printing - event traces for configuration and parameter setting via PC extra code for the data transfer from and to the recorder Supply voltage V AC +10/-15% 48 63Hz V AC/DC ±0% 48 63Hz - measurement traces - text printing (limited) not available not available V AC +10/-15% 48 63Hz V AC/DC ±0% 48 63Hz Features of the k Limit monitoring k Event traces k Four open-collector outputs k Peak value recording k Extensive text printing k Statistics (report) with minimum, maximum and mean values k Event- and time-controlled chart speed k Math and logic module (PC setup program is required) k Universal chart cassette Approvals Type

2 JUMO GmbH & Co. KG Fulda, Germany Data Sheet Page 2/12 Technical data Thermocouple input () Designation Range Linearisation accuracy 1 Fe-Con L DIN Fe-Con J EN Cu-Con U DIN Cu-Con T EN NiCr-Ni K EN NiCr-Con E EN NiCrSi-NiSi N EN Pt10Rh-Pt S EN Pt13Rh-Pt R EN Pt30Rh-Pt6Rh B EN to C -210 to C -200 to C -270 to C -270 to C -270 to C -270 to C -50 to C -50 to C C Shortest span Types L, J, U, T, K, E, N: Types S, R, B: Range start/end Cold junction ±0.2% ±0.2% above -200 C ±0.3% ±0.5% above -200 C ±0.2% above -150 C ±0.2% above -200 C ±0.2% above -150 C ±0.5% above 0 C ±0.5% above 0 C ±0.5% above 500 C 100 C 500 C freely programmable within the limits in 0.1 C steps Pt 100 internal or thermostat as external constant Cold junction accuracy (internal) ± 1 C Cold junction temperature (external) Measurement time Input filter Features -50 to +100 C, adjustable through setup software for 3 channels < 2sec; for 6 channels < 4sec 2nd order digital filter; filter constant adjustable from sec also programmable in F; customer-specific linearizations 1 The linearization accuracy refers to the maximum span. The linearization accuracy is reduced for shorter spans. 2 invalid DIN since 1995 Resistance thermometer input () Pt 100 EN Pt 100 JIS Pt 500 DIN Pt 1000 DIN Ni 100 Connection type Connection Range Linearisation accuracy Meas. current -200 to +250 C -200 to +850 C -200 to +250 C -200 to +850 C -200 to +260 C -200 to +649 C -200 to +260 C -200 to +649 C -200 to +150 C -200 to +850 C -200 to +150 C -200 to +850 C -200 to +250 C -200 to +850 C -200 to +250 C -200 to +850 C -60 to +125 C -60 to +180 C -60 to +125 C -60 to +180 C ±0.6 C ±1.0 C ±0.5 C ±0.8 C ±0.6 C ±1.0 C ±0.5 C ±0.8 C ±0.6 C ±1.0 C ±0.5 C ±0.8 C ±0.6 C ±1.0 C ±0.5 C ±0.8 C ±0.6 C ±1.0 C ±0.5 C ±0.8 C 2-, 3- or circuit Shortest span 15 C Probe lead resistance Range start/end Measurement time Input filter Features max. 30 Ω per core for circuit max. 20Ω per core for 2- and 3-wire circuit for Pt 100 up to 260 C max. 10 Ω per core in 2-wire and 3-wire circuit freely programmable within the limits in 0.1 C steps for 3 channels < 2sec; for 6 channels < 4sec 2nd order digital filter; filter constant adjustable from 0 50sec also programmable in F; customer-specific linearizations

3 JUMO GmbH & Co. KG Fulda, Germany Data Sheet Page 3/12 Resistance transmitter and potentiometer input () Range Accuracy Measuring current up to 200Ω up to 400Ω up to 800Ω up to 2000Ω up to 4000Ω Connection type Shortest span Probe lead resistance Resistance values Measurement time Input filter Input for DC voltage or DC current ( and Type ) Basic range Accuracy Input resistance -25 to +75mV 0 100mV -100 to +100mV 0 200mV -500 to +500mV 0 1V -1 to +1V -5 to +5V 0 10V -10 to +10V Shortest span Range start/end 4 20mA 0 20mA -20 to +20mA Shortest span Range start/end Measurement time Input filter Features Transducer short-circuit/break ±300mΩ ±600mΩ ±1Ω ±2Ω ±3Ω ±100μV ±100μV ±150μV ±150μV ±1mV ±1mV ±2mV ±10mV ±10mV ±15mV ±20μA ±20μA ±40μA resistance transmitter: 3-wire circuit potentiometer: 2-, 3- or circuit 6Ω max. 30Ω per core in circuit max. 20Ω per core in 2-and 3-wire circuit up to 200 Ω range: max. 10 Ω per core in 2-and 3-wire circuit freely programmable within the limits in 0.1Ω steps for 3 channels < 2sec; for 6 channels < 4sec 2nd order digital filter; filter constant adjustable from sec R E > 0.5 MΩ R E > 0.5 MΩ R E > 0.5 MΩ 5mV freely programmable within the limits (up to 999mV in 0.01mV steps, from 1V in 1mV steps) burden voltage 2.6V max. burden voltage 2.6Vmax. burden voltage 2.6Vmax. 0.5mA freely programmable within the limits in 0.1mA steps for 3 channels < 2sec; for 6 channels < 4sec 2nd order digital filter; filter constant adjustable from sec for : adjustable linearizations for thermocouples and resistance thermometers (for connection to transmitters without linearization) Short-circuit 1 Break 1 Thermocouple not recognized recognized Resistance thermometer recognized recognized 2 Resistance transmitter recognized recognized Potentiometer not recognized recognized 2 Voltage up to ± 1V not recognized recognized Voltage above ± 1V not recognized not recognized Current not recognized not recognized 1 The print head is positioned to 0%, >>>>>> appears in the LED dot-matrix display. 2 In circuit: only recognized at terminals 1 and 2. Outputs () Three open-collector outputs One open-collector output Printing system ( and Type ) Drive Sensitivity Reproducibility Display and recording accuracy to signal over/underlimit to signal faults (e. g. end of chart) stepper motor 0.2% or better referred to 100mm writing width 0.25% or better referred to 100mm writing width Class 0.5 referred to range limits and basic ranges

4 JUMO GmbH & Co. KG Fulda, Germany Data Sheet Page 4/12 Print head Print colors Over/underrun Chart speed Paper feed Chart cassette Chart overall width / writing width sprocket roller spacing visible diagram length overall length print head with penlift function - sufficient for approx. 1 million dots (depending on the ambient temperature) Violet, red, black for 3-channel printing recorder and violet, red, black, green, blue, brown for 6-channel printing recorder. For the color assignment can be changed at will, through the setup program. electronically limited to 0 100mm writing width programmable in the steps 0, 5, 10, 20, 60, 120, 240, 300, 360, 600, 720mm/h by stepper motor and gearing cassette for roll chart and fanfold chart (with tear-off edge and paper-end switch) roll or fanfold chart to DIN mm / 100mm 110mm roll chart: 60mm; fanfold chart: 30 60mm roll chart: 16m or 32m; fanfold chart: 16m Electrical data ( and Type ) Supply (SMPS) V AC +10/-15% AC 48 63Hz, or 20 53V ±0% AC/DC 48 63Hz Electrical safety to EN , Part 1, March 1994 overvoltage Category II, contamination Grade 2 Test voltages (type test) mains supply to measurement circuit with AC supply 2.3kV 50Hz, 1min; with AC/DC 510V 50Hz, 1min mains supply to housing with AC supply 1.5kV 50Hz, 1min; with AC/DC 510V 50Hz, 1min between measurement circuits 200V 50Hz, 1min measurement circuits to housing 500V 50Hz, 1min electrical isolation between the analog inputs up to 30V AC and 50V DC Supply voltage sensitivity less than 0.1% of range span Power consumption 35VA max. Data buffering More than 4 years through lithium battery in RAM or 2 days with storage capacitor at 5 25 C ambient temperature. Additional backup in EEPROM. Electrical connection Electromagnetic compatibility (EMC) interference emission immunity to interference Housing ( and Type ) Housing type housing door Transport mechanism Chart cassette Bezel size Depth behind panel Panel cut-out At rear through plug-in screw terminals, max. conductor cross-section 2.5mm 2 or 2x 1.5mm 2 with core end sleeves. For : Setup connector at the front behind flip-up dot-matrix display EN Class B to industrial requirements Housing for front-panel mounting to IEC , galvanized sheet steel cast zink in corrosion-resistant chrome-nickel steel in plastic (polycarbonate) 144mm x 144mm 212mm without screw terminals; 227mm with screw terminals plugged in mm x mm Housing mounting in control panel to DIN Ambient temperature range Ambient temperature error Storage temperature range Climatic conditions 0 to +50 C 0.2%/10 C -20 to +70 C (without print head), -20 to +55 C (with print head) 20 70% relative humidity, no condensation Operating position normal position: vertical ± 30 (NL 90 ± 30, to DIN ) Protection to EN Category 2, front IP54 (IP65 with extra code 266), rear IP20 Weight 3.5 kg max. Approvals/marks of conformity Mark of conformity c UL us Testing laboratory Underwriters Laboratories Certificates / certification numbers Test basis E UL CAN/CSA C22.2 No valid for the flush-mounted instrument; not in conjunction with any housing extra code

5 JUMO GmbH & Co. KG Fulda, Germany Data Sheet Page 5/12 Operating modes Limit monitoring Eight limit comparators are available to monitor the limits. Limits, differential values (hysteresis), limit comparator functions (lk), texts and the channels to be monitored can be programmed. The result of the monitoring is fed to the open-collector outputs (1 3) and the optional relay module (1 8) as limit state (logic 0 or 1). The different lk functions are: lk 7: The limit state is set to 1 when: measurement > limit + upper differential. lk8: as lk7, but function is reversed. Chart speeds The LOGOPRINT 500 can be programmed with four different operating modes for the chart speed: 1. Normal operation 2. Limit operation If the measurement goes above/below the programmed limits, the recorder switches to the speed which has been programmed under limit operation. 3. External operation A signal on one of the logic inputs at the back of the recorder switches to the speed which has been programmed under external speed. 4. Timed operation The chart speed which is operative within a programmable time span. Type The LOGOPRINT 500 junior has no limit monitoring. Only normal operation is possible as chart speed. Graphic print-out Measurement traces Zoom (plot area) In zoom operation, an enlarged recording is made of a section of the full range of a trace. Presentation range (offset) This parameter is used to define the presentation range of a trace on the chart. This assists the evaluation, in particular of traces which are close to each other or which overlap. Peak value recording The peak value recording can be switched on or off for each channel. In the switched-off state, the present value of a channel is printed. Since more values can be measured than can be printed, the minimum and maximum values measured between two lines to be printed are stored when the peak value recording is switched on. These minimum and maximum values are printed when peak value recording is activated. Event traces Eight event traces can be printed. Limit monitoring (limit comparators) or the state of the optional logic inputs can thus be documented on the chart. Type The entire chart width for each measurement trace is available here. The functions zoom, presentation range, peak value recording and event traces are not applicable. Text printing Text printing is used for comments on the recorded trace and for event recording. Printing priorities can be assigned to texts, to serve as abort criteria during simultaneous text printing requests. Text printing can be separately configured for each text, either time-optimized or during continued recording of traces. Type The priorites and the printing mode are strictly defined here. Text printing facilities for and Type : - Time, date - Scaling of the channels - Channel numbers - Change of chart speed - Recording start/end text - Power on and power off text - Print text to check the printing system and the service print Additional text printing facilities for : - 16 limit comparator texts 1 (eight for underlimit and eight for overlimit) - 2 reports (calculate and print minimum, maximum and mean values) - Eight external texts 1 (extra code) - 16 binary-linked external texts 1 (extra code) - Event counter 1 (extra code) 1 These texts are buffered through a queue. As long as the queue is not full, complete documentation is assured. Extra codes RS422/RS485 interface This interface is intended for communication with higher-level systems (e. g. bus system or PC). It can be used to read out measurements, to monitor operating states and to transmit texts and values to the recorder. Logic inputs Eight logic inputs can be operated either through floating contacts or by the following voltage levels: inactive: 0 5V / active: 20 35V The voltage levels must be applied for 0.4sec. Functions available include: - External start/stop - Activate external chart speed - Text printing - Start/stop external report - Start scaling print - Increment two event counters - Key inhibit - Event traces Supply for 2-wire transmitter An electrically isolated supply for a 2-wire transmitter is available. 24V DC 45mA ± 5% ER8 external relay module The LOGOPRINT 500 can be equipped with an ER8 external relay module (eight relay outputs) to monitor infringements of upper and lower limits. The relay outputs are permanently assigned to the limit comparators. The assignment to the measurement channels can be made freely through the limit comparator parameter. Contact rating: 3 A 250V AC 50Hz, or 3 A 30V DC resistive load

6 JUMO GmbH & Co. KG Fulda, Germany Data Sheet Page 6/12 Display and controls Fault signal LED 24-character green LED dot-matrix display Print head Keys for operating and programming Setup interface (behind the swing-up LED dot-matrix display) Operation and configuration and Type At the recorder The eight keys on the instrument are used for operating the instrument, and to configure all the parameters essential to the operation. The 24-character dot-matrix display is available for indicating and monitoring the measurements and parameters. Housing door Chart paper Channel label Panel-mounting housing to IEC in galvanized sheet steel Setup program () Via the setup program for PC (accessory) The recorder can be configured using the setup program for PC (see diagram, bottom left) more conveniently than by using the instrument keys. The configuration data of a configured instrument can be read out and altered using the setup program. For a further instrument with the same configuration, the data can be copied through the setup program. The configuration data can be archived on data media and printed out. In addition to the programming possibilities from the keys of the recorder, the setup program offers the following extra functions: - Setting different print colors - Customer-specific linearizations - Setting the printing mode for the texts (printing mode: Overwrite measurement trace or Interrupt measurement trace ) - Printing priorities - Math and logic module editor - Various settings can be managed Customer-specific linearizations The setup program offers a choice between linear, square law and cube law linearization. There can be up to 41 calibration points for linear and square law linerarization, and up to 61 calibration points for cube law linearization. These calibration points are used to determine the coefficients for polynomials which are defined for each section, so that even a few calibration points produce a smooth graph. Accuracy: depends on the shape of the graph and the selected linearization. Language and Type The language setting (English, German, French) appears in the print-out and on the LED dot-matrix display.

7 JUMO GmbH & Co. KG Fulda, Germany Data Sheet Page 7/12 Example of a recording with text print-out for (1) Recording start/end text (2) Speed change to 120 mm/h through a logic input (3) Printing the time (with every fourth print-out, the current chart speed, the programmed instrument name, or the date are printed alternately). (4) If a selectable logic input is closed, the count of an event counter is incremented and documented together with the programmed text. Altogether, two event counters are available. (5) The scaling of all active channels can be printed, either by pressing the F key (hold down for at least 4 sec), or through a logic input. (6) The channel number can be printed in the selected channel color so that individual traces can be more easily differentiated. (7) Documentation of over/underlimit conditions in the limit comparators. (8) A total of eight event traces can be printed out. They can be used either to document the state of the limit comparators, or that of the logic inputs. The position of the event traces on the chart can also be programmed. (9) Additional texts (external texts) can be printed if one logic input, or a combination of up to four logic inputs, is switched. (10)Print-out of a report. The print-out shows the period of time in which the measurements were acquired and calculated, as well as the minimum, maximum and mean values of all active channels (including channel name and unit). (11)As opposed to (5), the scaling of the channels can be performed alternately in a programmable spacing. All texts which relate to a logic input can only be printed if the extra code 8 logic inputs (code 259) has been implemented in the recorder. In the example, the traces which were printed above the report (10), are printed out in the normal mode, i.e. all traces share the entire chart width (0 100mm). The presentation range can be selected freely on the chart for each trace. This assists the evaluation, in particular of traces which are close to one another or which overlap. The traces below the report have thus been arranged over two sections of the chart (0 50mm and mm). (1) (2) (3) (4) (3) (5) (1) (7) (9) (9) (7) (10) (6) (6) (6) (6) (8) (3) (11) (3) (3)

8 JUMO GmbH & Co. KG Fulda, Germany Data Sheet Page 8/12 Connection diagram for maximum terminal assignment Rear view of 3/6-channel version with plug-in screw-clamp connectors Connection for 3/6-channel version Diagram Supply as on label N neutral L1 line PE protective earth Connector 10. Analog inputs Inputs Connector Thermocouple Resistance thermometer in 2-wire circuit Resistance thermometer in 3-wire circuit Resistance thermometer in circuit

9 JUMO GmbH & Co. KG Fulda, Germany Data Sheet Page 9/12 Analog inputs Resistance transmitter in 3-wire circuit Inputs Connector Diagram A = start S = slider E = end Potentiometer in 2-wire circuit Potentiometer in 3-wire circuit Potentiometer in circuit Analog inputs and Type Voltage input up to ± 1V Inputs Connector Voltage input above ± 1V Current input ± 20mA Current input (shunt) ±20mA (when using transducers with changeable internal resistance; extra code terminal with shunt is required)

10 JUMO GmbH & Co. KG Fulda, Germany Data Sheet Page 10/12 Inputs/outputs Connector Diagram ER8 external relay module Communication with external relay module Voltage source for external 2-wire transmitter 24V 45mA ± 5% Logic operating inputs Contact operation LOW = R OFF 100kΩ HIGH = R ON 50kΩ 7. min. pulse length: HIGH 400msec LOW 400msec Open-collector outputs RS422/RS485 serial interface Voltage operation LOW = 0 5V DC (inactive) HIGH = 20 35V DC (active) contact no. 7 = logic input 1... contact no. 14 = logic input 8 DOUT1 DOUT4 U max = 32V DC I max = 100mA 8. Residual voltage DOUT active U DOUTactive = V Communication with higher-level systems 9. Overview of the electrical isolation

11 JUMO GmbH & Co. KG Fulda, Germany Data Sheet Page 11/12 Dimensions Panel-mounting housing Extra code Housing with carrying handle, rubber feet and terminal cover, also 3m mains cable with earthed plug Extra code Housing for wall mounting. The panel-mounting housing is fitted in a carrier and can be swung out through 90. Extra code TG-35 Portable recorder housing for varying applications in mobile use

12 JUMO GmbH & Co. KG Fulda, Germany Data Sheet Page 12/12 Order matrix: (1) Basic version /14 LOGOPRINT 500 with 3 universal inputs /15 LOGOPRINT 500 with 6 universal inputs /15 LOGOPRINT 500junior with 6 inputs for standard singals (2) Inputs 1 3 (programmable) x x x 888 factory-set x x x 999 configuration to customer specification 1 (3) Inputs 4 6 (programmable) x 000 not assigned x x 888 factory-set x x 999 configuration to customer specification 1 (4) Interface x x x 00 not assigned x x 52 RS422, Jbus, Modbus x x 53 RS485, Jbus, Modbus (5) Supply x x x V AC/DC +0/-0% 48 63Hz x x x V AC +10/-15% 48 63Hz (6) Extra codes x x x 020 lithium battery for RAM buffer (ex-factory) x x x 021 storage capacitor for RAM buffer (on request) x x x 030 terminal with shunt (6 items) x x logic inputs, interface for external relay module (ER8), voltage output 24V 50mA DC x x x 265 door with lock (IP54) x x x 266 IP65 seal, wide fixing brackets x x x 350 universal carrying case TG-35 2 x x x 351 housing with carrying handle 3 x x x 247 housing for wall mounting (can be swung through 90 ) 3 (1) (2) (3) (4) (5) (6) Order code /,... 4 Order example / / Please specify probe types and measurement ranges in plain text. 2 This extra code is available in combination with supply voltage V AC, not with low supply voltage. UL approval is not available. The protection type in the carrying case corresponds to IP20, outside IP20D. 3 UL approval is not available. 4 Extra codes are listed in sequence and separated by a comma. Standard accessories - 1 Operating Instructions - 2 mounting brackets - cable-tie with foot (can be released), for tension relief of the sensor leads connected - 1 print head, 3 colors (each color is available twice) or 1 print head, 6 colors - 1 roll chart 32m long and 1 fanfold chart pack 16m long Accessories (Data Sheet ) - For further accessories, see data sheet Consumables part number - Print head (2 items), 3 colors 70/ Print head (2 items), 6 colors 70/ Roll chart (5 rolls), no name, % graduation, linear; overall length 16m, overall width 120mm 70/ Roll chart (5 rolls), no name, % graduation, linear; overall length 32m, overall width 120mm 70/ Roll chart (5 rolls), no name, special graduation, linear; marked as specified - - Fanfold chart (5 packs), no name, % graduation, linear; overall length 16m, overall width 120mm 70/ Fanfold chart (5 packs), no name, special graduation, linear; marked as specified -

J TB/TW Temperature limiter, temperature monitor

J TB/TW Temperature limiter, temperature monitor JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Entry-level Paperless Recorder with CompactFlash card and life-cycle data management

Entry-level Paperless Recorder with CompactFlash card and life-cycle data management JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

JIMAGO 500 Multi-channel Process and Program Controller

JIMAGO 500 Multi-channel Process and Program Controller JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 60030 Fax: +49 661 6003607 email: mail@jumo.net Internet: www.jumo.net

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Portable digital microprocessor thermometers with interchangeable probes

Portable digital microprocessor thermometers with interchangeable probes JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

TX OPEN RS232/485 module

TX OPEN RS232/485 module s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Digital display DA 48

Digital display DA 48 Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital

More information

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Digital Pressure Measuring Instrument MDR480

Digital Pressure Measuring Instrument MDR480 Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

HCR3.2/.. Chipcard reader HOTEL SOLUTION

HCR3.2/.. Chipcard reader HOTEL SOLUTION s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages

More information

Hand-held thermometer Model CTH7000

Hand-held thermometer Model CTH7000 Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference

More information

JUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules

JUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules 0888-0172/0002-3601 JUMPFLEX 857 Series 2.0 E 12/08 Printed in Germany Subject to design changes 2...10 V 0...20 ma 4...20 ma WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 32385 Minden Hansastraße 27

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion

More information

Disturbance Recoder SPCR 8C27. Product Guide

Disturbance Recoder SPCR 8C27. Product Guide Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

SINEAX U553 Transducer for AC Voltage

SINEAX U553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.

More information

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low

More information

Test equipment for temperature and its reduction

Test equipment for temperature and its reduction Data sheet 90.2721 Page 1/6 Test equipment for temperature and its reduction Pt100 precision RTD temperature probe Calibrated temperature measuring chain with precision display device Calibrations as service

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

Safety Relays ESM/ESM-F

Safety Relays ESM/ESM-F Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011 Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Product Information Fire alarm panel 8000 C

Product Information Fire alarm panel 8000 C Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum

More information

Product Information Sheet UH36 Hi Pot Tester

Product Information Sheet UH36 Hi Pot Tester Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information

PHOENIX CONTACT - 2012-12-14. Features

PHOENIX CONTACT - 2012-12-14. Features Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed

More information

Air damper actuators

Air damper actuators 4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

WEB log. Device connection plans

WEB log. Device connection plans WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20160425* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building

More information

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Combi switchbox with integrated 3/2 way pilot valve

Combi switchbox with integrated 3/2 way pilot valve H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled

More information

PIEZOMETER AIRFLOW MEASURING RING

PIEZOMETER AIRFLOW MEASURING RING PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Secure Data Management and FDA-Compliant Measured Data Recording

Secure Data Management and FDA-Compliant Measured Data Recording Phone: 9 661 600-0 Fax: 9 661 600-607 Phone: 179 655 Fax: 179 656 Data Sheet 706585 Page 1/1 Secure Data Management and FDA-Compliant Measured Data Recording Brief description LOGOSCREEN fd The LOGOSCREEN

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

instabus KNX / EIB System System E F G H

instabus KNX / EIB System System E F G H Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Multi-Protocol decoder 76 200 with Load regulation

Multi-Protocol decoder 76 200 with Load regulation Multi-Protocol decoder 76 2 with Load regulation For locomotives with universal motors on digital layouts operating in the DCC and Motorola data format. Features 76 2 Load regulated multi-protocol decoder

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information