SINEAX U553 Transducer for AC Voltage

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "SINEAX U553 Transducer for AC Voltage"

Transcription

1 With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load independent DC voltage proportional to the measured value. he transducer fulfi ls all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 00 resp. EN 00). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 00. Fig.. ransducer SINEAX U55 in housing P/0 clipped onto a top-hat rail. Features / Benefits Measuring input: AC voltage, sine or distorted wave forms, RMS value measurement Measured variable AC voltage Measuring range limits 0 0 to 0 0 V he output amplifi er transforms the measuring signal into an impressed DC current output signal A. he electronic components are supplied with voltage H from the mains supply unit H. Measuring output: Unipolar and live-zero output variables Measuring principle: Logarithmic method AC/DC power supply / Universal U~ Ueff = u dt o A Standard version as per Germanischer Lloyd H Fig.. Block diagram. Mode of operation Input signal U~ is galvanically separated from the mains network using a transformer. he following mathematical expression is then formed using a root-mean-square value computer U eff = o u dt Following fi ltration by means of an active fi lter, the transformation properties of the measuring transducer are determined in the succeeding characteristics circuit. echnical data General Measured quantity: Measuring principle: AC voltage Sine or distorted wave forme RMS value measurement Logarithmic method Camille Bauer Data sheet U55 Le 0.

2 Measuring input E Nominal frequency f N : Nominal input voltage U N (measuring range end value): Setting: 50/0 or 400 Hz 0 0 to 0 0 V Admissible alteration of full-scale output, variable sensitivity, adjustable with potentiometer Setting range U N (± 5%) 00% U N Voltage limit under R ext = : Residual ripple in output current: Setting time: 5 V 0.5% p.p. at setting time 00 ms % p.p. at setting time 50 ms 50 ms or 00 ms Power supply H AC/DC power pack (DC or 50/0 Hz) able : Rated voltages and permissible variations Rated voltage olerancd 5 0 V DC / AC DC 5 + % 4 0 V DC / AC AC ± 5% Own consumption: Overload capacity: Measured quantity U N Number of applications 0Output 0 Input VA with input end value Duration of one application Interval between two successive applications. U N continuously U N 0 s 0 s But max. 4 V with power supply from measuring input Measuring output A Load-independent DC current: Burden voltage: 0 to 0 0 ma resp. live-zero 0. to 4 0 ma 5 V External resistance: R ext max. [kω] = 5 V I AN [ma] I AN = Output current end value Load-independent DC voltage: 0 to 0 0 V resp. live-zero 0. to 0 V External resistance: R ext [kω] U [V] A ma Current limit under overload:.5 I AN at current output Approx. 0 ma at voltage output Option: Power consumption: Accuracy (acc. to EN 0 ) Connected to the low tension terminal side and 4 V AC or 4 0 V DC VA Reference value: Output end value Basic accuracy: Class 0.5 Reference conditions: Ambient temperature 5 0 C Input variable Rated operating range Frequency f N ± Hz Curve shape Sine-wave Crest factor Power supply In rated range Output burden Current: 0.5 R ext max. Voltage: R ext min. Warm-up time 5 min. Influence effects (maxima): included in basic error Frequency Hz, ± 0.% Hz, ± 0.5% Crest factor.5 ± 0.% >.5 ± 0.5% Safety Protection class: II (protection isolated, EN 00) Housing protection: IP 40, housing (test wire, EN 0 5) IP 0, terminals (test fi nger, EN 0 5) Contamination level: Overvoltage category: III Data sheet U55 Le 0. Camille Bauer

3 Rated insulation voltage (versus earth): 400 V, input 0 V, power supply 40 V, output est voltage: 50 Hz, min. acc. to EN resp V, input versus all other circuits as well as outer surface 00 V, power supply versus output as well as outer surface 40 V, output versus outer surface Installation data Mechanical design: Housing P/0 Material of housing: Lexan 40 (polycarbonate), fl ammability Class V-0 acc. to UL 4, self-extinguishing, non-dripping, free of halogen Mounting: For rail mounting Mounting position: Any Weight: Approx. 0. kg Connecting terminals Connection element: Permissible cross section of the connection leads: Screw-type terminals with indirect wire pressure 4.0 mm single wire or.5 mm fi ne wire Environmental conditions Operating temperature: 0 to + 55 C Storage temperature: 40 to + 0 C Relative humidity of: 5%, no dew Altitude: 000 m max. Indoor use statement! Ambient tests EN 0 0--: Acceleration: Frequency range: Number of cycles: EN 0 0--: Acceleration: EN 0 0--/-/-: IEC /-/-4/-5/- EN 55 0: Germanischer Lloyd ype approval certifi cate: Ambient category: Vibrations: Vibration ± g Hz, rate of frequency sweep: octave/minute 0, in each of the three axes Shock 50 g shocks each in directions Cold, dry heat, damp heat Electromagnetic compatibility No. 5- HH C 0. g able : Specification and ordering information Designation *Blocking No-go with Article No./ code blocking code Feature SINEAX U55 Order Code 55 - xxxx xx 55 Features, Selection. Mechanical design Housing P/0 for rail mounting 4. Nominal input frequency 50/0 Hz 400 Hz Continuation see on next page! Camille Bauer Data sheet U55 Le 0.

4 Designation *Blocking No-go with Article No./ code blocking code Feature SINEAX U55 Order Code 55 - xxxx xx 55 Features, Selection. Measuring range 0 00 / A A 0 0 / A B 0 00 B C 0 0 B D 0. B E 0 0 B F 0 5 B G 0. B H 0 50 B J 0 50 C K 0 500* C L Non-standard [V] Z 0 0 to 0 0 V With power supply from measuring input min. 4 V / max. 0 V, see feature 5, lines and 4. * Max. 400 V nominal value of the network against earth (operating voltage acc. to EN 00) 4. Output signal 0 0 ma, R ext 50 Ω 4 0 ma, R ext 50 Ω Non-standard [ma] 0.00 to 0 < 0 0. to < (4 0) 0 0 V, R ext 5 kω A Non-standard [V] Z 0.00 to 0 < 0 0. to 0 5. Power supply 5 0 V DC / AC 4 0 V DC / AC From measuring input 4 0 V AC BC From measuring input 5 0 V AC AC 4 Connected to the low tension terminal side and 5 4 V AC / 4 0 V DC. Setting time 0. s 50 ms *Lines with letter(s) under no-go cannot be combined with preceding lines having the same letter under Blocking code. 4 Data sheet U55 Le 0. Camille Bauer

5 Electrical connections 0 0 ( )(+) 0 U ( )(+) U Fig.. Power supply connected to terminals and. Fig. 4. Power supply internal from measuring input, without separated power supply connected. U Fig. 5. Power supply connected to the low tension terminal side and. = Measuring input = Measuring output = Power supply Dimensional drawing Fig.. SINEAX U55 in housing P/0 clipped onto a top-hat rail (5 5 mm or 5.5 mm, acc. to EN 50 0). Rely on us. Standard accessories Operating Instructions in three languages: German, French, English Camille Bauer AG Aargauerstrasse CH-50 Wohlen / Switzerland Phone: + Fax: + Subject to change without notice Edition 0. Data sheet U55 Le

SINEAX SI 815 Passive DC Signal Isolator

SINEAX SI 815 Passive DC Signal Isolator with power supply transfer and without separate power supply connection, versions available for FSK 1 and Ex and non-ex, in housing N17 or S17 for rail and wall mounting 0102 II (1) G Application The signal

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

SIRAX SI 815 Passive DC Signal Isolator

SIRAX SI 815 Passive DC Signal Isolator with power supply transfer and without separate power supply connection, versions available for FSK, Ex and non-ex versions 002 II () G Application The signal isolator SIRAX SI 85 (Fig. ) serves to electrically

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

SINEAX VC604s Programmable Safety Value Converter

SINEAX VC604s Programmable Safety Value Converter SINEAX VC60s f direct currents, direct voltages, temperature senss, teletransmitters potentiometers SINEAX VC60s is a multifunctional transmitter f tophat rail assembly with the following main characteristics:

More information

Measuring transducers for all electrical AC-variables

Measuring transducers for all electrical AC-variables Measuring transducers for all electrical AC-variables SWMU Measuring transducer for AC with integrated current transformer...................236 page Order List page NMC Clip-on measuring transducers for

More information

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters Characteristics voltage control relay RM17-U - range 65..260 V AC Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main Range of

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Model EPS240-12 EPS240-24 EPS240-48. Rated Power: 240W 240W 240W. >0,98 for 115V AC full load, >0,94 for 230V AC full load

Model EPS240-12 EPS240-24 EPS240-48. Rated Power: 240W 240W 240W. >0,98 for 115V AC full load, >0,94 for 230V AC full load EPS240 Series Single Phase Primary Switch DC Power Supply Unit Universal AC/DC Input Easily Din Rail Installation High Reliability And Durability LED Indicator For Functions Control I. Technical Data Model

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions

More information

Assembly. Front view. Switch S1. Power Rail

Assembly. Front view. Switch S1. Power Rail Temperature Repeater Features Assembly 1-channel isolated barrier V DC supply (Power Rail) Resistance and RTD input (Pt100, Pt500, Pt1000) Resistance output Accuracy 0.1 % Line fault detection (LFD) for

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

PHOENIX CONTACT - 2012-12-14. Features

PHOENIX CONTACT - 2012-12-14. Features Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

Time relay module DC 24 110 V, programmable with positive action contacts

Time relay module DC 24 110 V, programmable with positive action contacts Subject to technical modification 815008.00 Identification Type ZR6-5008.00 Product version Datasheet version 00 Use/Application/Properties Description The programmable time relay consists of 1 relay with

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

Screw-in RTD temperature probe with plug connector according to DIN EN 175301

Screw-in RTD temperature probe with plug connector according to DIN EN 175301 ata sheet 902044 Page 1/8 Screw-in RT temperature probe with plug connector according to IN EN 175301 For temperatures between -50 and +260 C Vibration-resistant design Plug connector locked against contact,

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V

More information

Current Transformer Voltage Transformer. Content

Current Transformer Voltage Transformer. Content Current Transformer Voltage Transformer Content Common technical description 1 Summary with rated output 2-4 Tube current transformer 5 Plug-In current transformer 5-8 Wound current transformer 9 Summation

More information

Timing relay module DC 24 110 V, programmable

Timing relay module DC 24 110 V, programmable Subject to technical modification 815000.00 Identification Type ZR6-5000.00 Product version Datasheet version 00 Use/Area of application Description The programmable timing relay consists of 2 changeover

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

2H167W-1 Power Supply

2H167W-1 Power Supply Sanken Power Systems UK Ltd. Sanken European Technology Centre Pencoed Technology Park Pencoed, Bridgend CF35 5HY U.K. 2H167W-1 Power Supply 317W Interleaved & PFC Synchronous Rectification Overview: Features:

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Electronic timer CT-TGD.12

Electronic timer CT-TGD.12 2CDC 251 098 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual. Manual Supplement Manual Title: ESA620 Getting Started Supplement Issue: 9 Part Number: 2814971 Date: 1/11 Print Date: January 2008 Page Count: 7 Revision/Date: This supplement contains information necessary

More information

Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact

Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact Data sheet Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact The CT-VWE is an electronic time relay with Impulse-ON function. It is from the CT-E range. The CT-E range is the economic range

More information

RM4TR32 three-phase network control relay RM4-T - range V

RM4TR32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 300..430 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

RE7TL11BU on-delay timing relay s - 24 V AC DC - 1OC

RE7TL11BU on-delay timing relay s - 24 V AC DC - 1OC Characteristics on-delay timing relay - 0.05..1 s - 24 V AC DC - 1OC Main Commercial Status Range of product Product or component type Component name Time delay type Time delay range [Us] rated supply

More information

Type 3374 Electric Actuator

Type 3374 Electric Actuator Type 3374 Electric Actuator Application Electric actuator for plant engineering and HVAC The actuator is a linear actuator with or without failsafe action available either in a version with a threestep

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

Differential pressure sensors

Differential pressure sensors 1 923 1923P01 Differential pressure sensors for neutral or slightly aggressive gases and liquids QBE61.3-DP.. Operating voltage AC 24 V or DC 18...33 V Output signal DC 0...10 V Connecting male thread

More information

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit

More information

ETD-SL-1T-DTF. Multifunctional Timer Relay With One Settable Time INTERFACE. Data Sheet. Description

ETD-SL-1T-DTF. Multifunctional Timer Relay With One Settable Time INTERFACE. Data Sheet. Description Multifunctional Timer Relay With One Settable Time INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description Multifunctional timer relay with non floating control input and one settable time. The flashing

More information

Chrome DIN Rail Power Supply 12V 10W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1AZ

Chrome DIN Rail Power Supply 12V 10W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

3-phase, bidirectional energy meter

3-phase, bidirectional energy meter Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Duct Temperature Sensors

Duct Temperature Sensors 1 762 1761P03 1762P01 Mounting flange AQM630 QAM21 Symaro Duct Temperature Senss QAM2161040 QAM2171040 Active senss f acquiring the air temperature in air ducts Operating voltage AC 24 V DC 13535 V Signal

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

41 Series - Low profile PCB relays A. Features Plug-in / PCB Relays

41 Series - Low profile PCB relays A. Features Plug-in / PCB Relays Series - Low profile PCB relays 8-12 - 16 A 41 Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

Pressure Sensors. for neutral and slightly aggressive liquids and gases

Pressure Sensors. for neutral and slightly aggressive liquids and gases 1909P01 Pressure Sensors for neutral and slightly aggressive liquids and gases QBE2003-P QBE2103-P High-precision measuring Measuring range 0 to 60 bar relative Supply voltage AC 24 V / DC 12...33 V or

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

DRC-100 series. 100W Single Output with Battery Charger (UPS Function) File Name:DRC-100-SPEC Sicherheit ID

DRC-100 series. 100W Single Output with Battery Charger (UPS Function) File Name:DRC-100-SPEC Sicherheit ID Bauar t gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 SPECIFICATION MODEL OUTPUT INPUT PROTECTION OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER VOLTAGE ADJ.

More information

Plug-in relays Mini ISO relays

Plug-in relays Mini ISO relays Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features Limiting continuous current 70 A Dimensional characteristics and the functional allocation of

More information

FREJA 300 Relay Testing System

FREJA 300 Relay Testing System Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Other version available (not certified, option X and P): see how to order on the next page Class 1 (kwh) according to EN62053-21 Class B (kwh) according to

More information

Electronic Amplifier Model VT 3013 and VT 3014

Electronic Amplifier Model VT 3013 and VT 3014 RA 29 93/06.98 Electronic Amplifier Model T 3013 and T 3014 (Series 3X) for the control of direct operated proportional directional valves, without positional feedback, Eurocard format RA 29 93/06.98 Replaces:

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Actuator for modulating control AME 435

Actuator for modulating control AME 435 Data sheet Actuator for modulating control AME 435 Description The actuator automatically adapts its stroke to the valve end positions which reduces commissioning time (self stroking). The advanced design

More information

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle s 4 502 ACVATIX Electromotoric rotary actuators for butterfly or slipper valves SAL.. with 90 rotary angle SAL31.. Operating voltage AC 230 V, 3-position control signal SAL61.. Operating voltage AC/DC

More information

JUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules

JUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules 0888-0172/0002-3601 JUMPFLEX 857 Series 2.0 E 12/08 Printed in Germany Subject to design changes 2...10 V 0...20 ma 4...20 ma WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 32385 Minden Hansastraße 27

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Voltage monitoring relays CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-EFS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

CQM1-SF200/CS1W-SF200

CQM1-SF200/CS1W-SF200 Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit

More information

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class

More information

MODEL: WRPPB. [3] OUTPUT 2 Same range availability as Output 1 (Q7 not selectable)

MODEL: WRPPB. [3] OUTPUT 2 Same range availability as Output 1 (Q7 not selectable) MODE: WRPPB Dual Output Plug-in Signal Conditioners W-UNIT ENCODER SIGNA DISTRIBUTOR (rotary encoder use, BNC connection) Functions & Features Isolating two phase pulse input signals from a rotary encoder

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

DC/DC Converter Model 1416

DC/DC Converter Model 1416 Power Conversion Model 1416 www.curtisinstruments.com Curtis Model 1416 is designed to be used on 24 and 6VDC battery-powered vehicles to provide reliable and regulated power to 24VDC accessories. Model

More information

RHINO PSM Series Power Supplies

RHINO PSM Series Power Supplies RHINO PSM Series Supplies Our versatile switching power supplies are DIN-rail mountable Features Industrial grade design Sturdy metal case to withstand harsh industrial environments Model PSM4-090S-N meets

More information

M A N U A L. Field Current Controller F2.2

M A N U A L. Field Current Controller F2.2 M A N U A L Field Current Controller F2.2 Industrie Elektronik G m b H Hans-Paul-Kaysser-Straße 1 71397 Leutenbach Nellmersbach Tel.: 07195 / 92 83 0 Fax: 07195 / 92 83 129 info@unitek-online.de www.unitek-online.de

More information

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information