Compressed Air Cleaning Filter Series

Size: px
Start display at page:

Download "Compressed Air Cleaning Filter Series"

Transcription

1 Compressed Air Cleaning ilter Series Series / or Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the.r.l. combination AC series. Possible to make a modular connection with products such as AR series regulator. Options added Addition: 5 types 1. MPa specifications luororubber specifications With differential pressure switch (125 VAC, 30 VDC) With differential pressure switch (30 VDC) Degreasing wash, white vaseline specifications Spacer Note) Note) Spacer with bracket cannot be mounted. Use the attached bracket. G C, C, C, D C H C, E C, C Differential pressure switch Height and mass reduced by up to 40% New G C, C, C, D C H C, E C, C Modular connection example H + E H + E + The C type is only suitable for modular connection. Compact, Lightweight (E C, C) Conventional HAA HAW AT ID IDU IDA IDB ID IDG G D H E S SD LLB AD GD Water Separation Water Separator/G Solid/Oil Separation Main Line ilter/ Mist Separator/ Micro Mist Separator/D Micro Mist Separator with Pre-filter/H Super Mist Separator/E Deodorization Odor Removal ilter/ 141

2 Water droplet removal Water Separator Water droplet separation rate: % 150C low capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 1/8, 1/4 Note 250C 750 1/4, 3/8 G 350C 450C 550C 1,500 2,0 3,700 3/8, 1/2 1/2, 3/4 3/4, 1 Piping support type 50,000 1, 1 1/2 G150C to 550C G50/ , /2, 2 Large dust particle filtration, Oil droplet separation 2C 4C /8, 1/4 1/4, 3/8 Main Line ilter Nominal filtration rating: 3 µm [iltration efficiency: %] 8C 11C 22C 37B 1,500 2,0 3,700,000 3/8, 1/2 1/2, 3/4 3/4, 1 1, 1 1/2 Piping support type 75B 75A 12, /2, 2 50(2B) flange 2C to 22C 37B/75B 75A to 2A 125A 150A 2A 22,000 28,000 42,000 80(3B) flange 0(4B) flange ree standing type Dust filtration, Oil mist separation 150C 250C /8, 1/4 1/4, 3/8 Mist Separator Nominal filtration rating: 0.3 µm [iltration efficiency:.%] Oil mist density at outlet: Max. 1.0 mg/m 3 (ANR) [ 0.8 ppm] 150C to 550C 50/ C 450C 550C ,500 2,0 3,700,000 12,000 3/8, 1/2 1/2, 3/4 3/4, 1 1, 1 1/2 1 1/2, 2 Piping support type Dust filtration, Oil mist separation 150C 250C /8, 1/4 1/4, 3/8 Micro Mist Separator Nominal filtration rating: 0.01 µm [iltration efficiency:.%] Oil mist density at outlet: Max. 0.1 mg/m 3 (ANR) [ 0.08 ppm] D 350C 450C 550C ,000 2,000 3,700,000 12,000 3/8, 1/2 1/2, 3/4 3/4, 1 1, 1 1/2 1 1/2, 2 Piping support type 801 8,000 50(2B) flange 01 24,000 50(2B), 80(3B), 0(4B) flange D150C to 550C D50, ,000 24,000 40,000 50(2B) flange 50(2B), 80(3B), 0(4B) flange 0(4B), 150(B) flange ree standing type 142

3 Series / Dust filtration, Oil mist separation Micro Mist Separator with Pre-filter Built-in 0.3 µm pre-filter The + D element have been integrated to achieve a space-saving design. Nominal filtration rating: 0.01 µm [iltration efficiency:.%] Oil mist density at outlet: Max. 0.1 mg/m 3 (ANR) [ 0.08 ppm] H150C to 550C H50/ C 250C 350C H 450C 550C low capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure ,000 2,000 3,700,000 12,000 1/8, 1/4 1/4, 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 1, 1 1/2 1 1/2, 2 Note Piping support type HAA HAW AT ID IDU IDA IDB ID IDG Dust filtration, Oil mist adsorption Super Mist Separator Color change indicates when element is saturated. Nominal filtration rating: 0.01 µm [iltration efficiency:.%] Oil mist density at outlet: Max mg/m 3 (ANR) [ ppm] Cleanliness at outlet: Not more than 35 particles of size 0.3 µm or larger/ l (0 particles or less/ft 3 ) E150C to 550C E50/850 Deodorization Odor Removal ilter Nominal filtration rating: 0.01 µm [iltration efficiency:.%] Oil mist density at outlet: Max mg/m 3 (ANR) [ ppm] E 150C 250C 350C 450C 550C C 250C 350C 450C 550C ,000 2,000 3,700,000 12, ,000 2,000 3,700,000 12,000 1/8, 1/4 1/4, 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 1, 1 1/2 1 1/2, 2 1/8, 1/4 1/4, 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 1, 1 1/2 1 1/2, 2 Piping support type Piping support type G D H E S SD LLB AD GD 801 8,000 50(2B) flange 150C to 550C 50, ,000 50(2B), 80(3B) 0(4B) flange 800 8,000 50(2B) flange ,000 40,000 50(2B), 80(3B) 0(4B) flange 0(4B), 150(B) flange ree standing type 143

4 Compressed Air Cleaning ilter Series Series / Series Water removal rate Nominal filtration rating Oil mist density at outlet Smell Page Water Separator Water Separator Eliminates water droplets in the compressed air. Series G % P.145 Main Line ilter Eliminates impurities such as oil and foreign matter, etc. in compressed air. Series 3 μm (iltration efficiency: %) P.153 Deodorizer Solid/Oil Separator Mist Separator Eliminates oil mist in compressed air or rust sized 0.3 μm or more, and foreign matter such as carbon. Micro Mist Separator Eliminates foreign matter sized 0.01 μm or more, or oil particles in an aerosol state. Micro Mist Separator with Pre-filter Oil separator, which incorporates pre-filter (equivalent to the series) into micro mist separator. Super Mist Separator Captures foreign matter sized 0.01 μm or more and adsorbs oil particles in an aerosol state. Odor Removal ilter Eliminates odor from compressed air. Series Series D Series H Series E Series 0.3 μm (iltration efficiency:.%) 0.01 μm (iltration efficiency:.%) μm (iltration efficiency:.%) 0.01 μm (iltration efficiency:.%) 1 mg/m 3 (ANR) ( 0.8 ppm) (after oil saturation) 0.1 mg/m 3 (ANR) ( 0.08 ppm) (after oil saturation) 0.01 mg/m 3 (ANR) ( ppm) mg/m 3 (ANR) ( ppm) Reduces oil smell. Deodorizes oil smell. P.11 P.1 P.17 P.187 P.15 Modular Connection Examples P.4 How to Order Bowl Assembly P. Options Seal material: luororubber - reversal direction Degreasing wash, or medium air pressure Drain guide 1/4 female threaded white vaseline With element service indicator With differential pressure switch (with indicator) (125 VAC, 30 VDC) With differential pressure switch (with indicator) (30 VDC) Refer to How to Order of respective models. Made to Order Applicable only to the 37B, 75B, 50 and 850. Special Specifications With differential pressure gauge Possible to control product, s service life by monitoring the clogged element. Auto drain type, drain guide specifications Drain piping is possible by auto drain type. With - flange lange piping connection is possible. Clean Series Usable inside a clean room. White vaseline specifications Using white vaseline for lubricant. With differential pressure gauge, - flange lange piping connection and clogged element confirmation are possible. With differential pressure switch (with indicator) Allows visual confirmation of differential pressure which indicates the element life. The built-in contact enables remote control. Cotter-free, luorine-free Series Eliminates the effects on a color CRT by copper ion or fluoric resin, etc. P.2 P.2 Related Products Auto Drain Valve, Motor Operated Auto Drain, Heavy Duty Auto Drain, Differential Pressure Gauge P.27 Specific Product Precautions P Discontinued and Equivalent P.2

5 Water Separator Series G RoHS Can remove water droplets in compressed air. Use this product in cases where water must be avoided, but not so dry as when an air dryer is used. Through the adoption of an element that is exclusively used for removing water droplets and the ample housing interior space, a % water removal rate has been achieved. Caution Water separator can remove water droplets, but it cannot remove moisture. Condition of inlet air Pressure: 0.7 MPa Temperature: 25 C Relative humidity: 0% Liquid water content (Water droplet content): 15 g/m 3 (ANR) Compressed air flow: Rated flow of each model Water removal rate (%) = Removed water (Water droplet) (g) x 0 Inflowed water (Water droplet) (g) Modular connection is possible with G150C to 550C. (or details, refer to page 4.) G150C G250C G350C G450C G550C G50 G850 Note) Rated flow (l/min (ANR)) Mass (kg) 1 8, , , , , , , 2.5 Note) Max. flow at 0.7 MPa. Max. flow varies depending on the operating pressure. Refer to low Characteristics (page 148) and Maximum Air flow (page 14). Specifications luid Compressed air Max. operating pressure 1.0 MPa Min. operating pressure 0.05 MPa Proof pressure 1.5 MPa Ambient and fluid temperature 5 to 0 C Water removal rate % Element life 2 years or when pressure drop reached 0.1 MPa With auto drain: 0.1 MPa (N.O. type) or 0.15 MPa (N.C. type) Accessory Applicable model Bracket assembly (with 2 mounting screws) Caution G150C G250C G350C G450C G550C G50 G850 -BM1 -BM2 -BM3 -BM4 -BM5 BM5 BM57 Be sure to read before handling. Refer to front matters 42 and 43 for Safety Instructions and pages to 8 for Air Preparation Equipment Precautions. HAA HAW AT ID IDU IDA IDB ID IDG G D H E S SD LLB AD GD G150C to 550C G G50/850 G (Drain cock specifications) (Auto drain specifications) Made to Order (or details, refer to page 2.) 145

6 Series G How to Order G150C to 550C G 550C Body size 150C 250C 350C 450C 550C Thread type Type Nil Rc G 1 N NPT 1 Conforms to ISO Applicable body size Size 150C 250C 350C 450C 550C 1/8 1/4 3/8 1/2 3/4 1 Accessory Nil B Bracket 2 2 Bracket is included, (but not assembled). 3 The model with bracket is not available for -X15. Made to Order ( How to Order and the applicable models are different from those shown on this page. Be sure to refer to Made to Order.) Nil X15 X2 With - flange 3 N.C., N.O. auto drain, drain piping type Option 4 Nil Rubber material: luororubber H or medium air pressure (1. MPa) J Drain guide 1/4 female threaded 5 R - reversal direction V Degreasing wash, white vaseline 5 Drain piping and piping for a stop valve such as ball valve are required. Only body/housing is degreasing washed. Page for details P.212 P.213 Auto drain 4 Nil Drain cock (Without auto drain) C N.C. auto drain D N.O. auto drain 4 Refer to Drain Exhaust Specifications/ Option Combinations. (Only one drain exhaust method can be selected.) Drain Exhaust Specifications/Option Combinations : All types of drain exhaust specifications are available. (including drain guide, J specification) : N.C. auto drain ( C specification) is not available. : Both N.C. and N.O. auto drain ( C, D specification) are not available. Nil Nil H R V : Not available H R V Options : Rubber material: luororubber luororubber is used for the parts such as O-ring and gasket. H: or medium air pressure (1. MPa) Can be used up to 1. MPa at maximum. J: Drain guide 1/4 female threaded Can be pipied to the drain exhaust port. 1/4 female threaded R: - reversal direction Air flow in the separator is changed to right to left. (Air flow direction of the standard: Left to right.) V: Degreasing wash, white vaseline Body/housing is degreasing washed. The lubrication grease for O-ring and gasket is changed to white vaseline. 14

7 Water Separator Series G How to Order G50/850 G 50 Body size Thread type Type Nil Rc G N NPT Size Applicable body size Accessory Nil B Bracket Bracket is included, (but not assembled). 2 The model with bracket is not available for -X15. Made to Order ( How to Order and the applicable models are different from those shown on this page. Be sure to refer to Made to Order.) Nil X15 X2 X12 Auto drain 3 Nil Drain cock (Without auto drain) 4 D N.O. auto drain 3 Refer to Auto Drain Specifications/Option Combinations. 4 Body size 850 is equipped with a ball valve (Rc 3/8 female threaded). Mount a piping adapter ID-AP0 (page 5) to the ball valve if NPT 3/8 female threaded is required. Auto Drain Specifications/Option Combinations Auto drain specifications/option Auto drain specifications Option N.O. auto drain Drain guide reversal direction D J R With - flange 2 N.C., N.O. auto drain, drain piping type White vaseline Option 3 Nil J Drain guide 1 4 female threaded 5 R - reversal direction 5 Drain piping and piping for a stop valve such as ball valve are required. Note) Element service indicator (symbol: T) is not available as an option because water deposits inside the indicator could lead to malfunctions. Page for details P.212 P.213 P.213 Note) Refer to How to Order Bowl Assembly on page. : Available : Not available Auto drain specifications Option Applicable model D J R G50 G850 HAA HAW AT ID IDU IDA IDB ID IDG G D H E S SD LLB AD GD 147

8 Series G low Characteristics (Representative values) Note) Compressed air over max. flow line in the table below may not meet the specifications of the product. G150C G450C G850 Air flow rate (l/min (ANR)) Air flow rate (l/min (ANR)) Air flow rate (m 3 /min (ANR)) G250C G550C Air flow rate (l/min (ANR)) Air flow rate (l/min (ANR)) G350C G50 Air flow rate (l/min (ANR)) Air flow rate (l/min (ANR)) 148

9 Water Separator Series G Construction G150C to 550C, G50 q G850 Component Parts No No. 4 Material Note Body Aluminum die-casted Chrome treated Aluminum die-casted Epoxy coating on Housing inner surface Sight glass Tempered glass The G850 is aluminum casted. Replacement Parts Material Element assembly Resin, others Applicable model Except option or option Maximum Air low G150C G-EL150 G-EL150- G250C G-EL250 G-EL250- G350C G-EL350 G-EL350- Note) Refer to How to Order Bowl Assembly on page. Note) Sight glass is indicated in the figure for easy understanding of component parts. However, it differs from the actual construction. Refer to dimensions on pages 150 to 152 for details. G450C G-EL450 G-EL450- Element assembly: With gasket (1 pc.) and O-ring (1 pc.) Refer to back page 21 for replacement of auto drain. Element assemblies for Made to Order (X12, X15, X2) are same as those for standard (see the above table). Max. air flow rate (m 3 /min (ANR)) r w e Selection G550C G-EL550 G-EL550- G50 G-EL50 G850 G-EL850 Select a model in accordance with the following procedure taking the inlet pressure and the max. air flow rate into consideration. (Example) Inlet pressure: 0. MPa Max. air flow rate: 5 m 3 /min (ANR) 1. Obtain the intersecting point A of inlet pressure and max. air flow rate in the graph. 2. The G50 is obtained when the max. flow line is above the interecting point A in the graph. Note) Make sure to select a model that has the max. flow line above the obtained intersecting point. With a model that has the max. flow line below the obtained intersecting point, the flow rate will be exceeded, thus leading to a problem such as being unable to satisfy the specifications. HAA HAW AT ID IDU IDA IDB ID IDG G D H E S SD LLB AD GD Inlet pressure (MPa) 14

10 Series G Dimensions G150C to 550C P Q Auto drain C: With auto drain (N.C.) D: With auto drain (N.O.) R O S Drain cock Gray: N.C. Black: N.O. 34 ø One-touch fitting D I Combination of D: With auto drain (N.O.) and H: or medium air pressure K U T L M øv Bracket (Accessory) N H C J A E B Note) 1/4 female threaded Note) 23 for G250C. Width across flats 17 Option J: Drain guide 1/4 female threaded G Maintenance space Drain port M5 Width across flats 24 1/4 female threaded G150C G250C G350C G450C G550C 1/8, 1/4 1/4, 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 A B C D E G 15 H I J K T 7 Bracket related dimensions U L M V N O P Q R (mm) S

11 Water Separator Series G Dimensions G50 Auto drain D: With auto drain (N.O.) Drain cock: Black HAA HAW AT ID IDU ø One-touch fitting IDA IDB 10 Option J: Drain guide 1/4 female threaded ID IDG Bracket (Accessory) 85 G Width across flats 24 1/4 female threaded D H E S SD 23 LLB Maintenance space Drain port M5 AD GD 151

12 Series G Dimensions G850 Auto drain 2 1 D: With auto drain (N.O.) for G Bracket (Accessory) /8 female threaded Maintenance space Drain Rc 3/8 female threaded 152

13 Main Line ilter Series RoHS Can remove impurities such as oil, water and foreign matter in compressed air and can improve the function of a dryer in the downstream, extend the life of precision filter, and prevent trouble with the equipment. Modular connection is possible with 2C to 22C. (or details, refer to page 4.) 37B/75B JIS 2C to 22C (Drain cock specifications) 75A to 2A JIS (Auto drain specifications) Made to Order (or details, refer to page 2.) Caution Be sure to read before handling. Refer to front matters 42 and 43 for Safety Instructions and pages to 8 for Air Preparation Equipment Precautions. 2C 4C 8C 11C 22C 37B 75B 75A 125A 150A 2A Rated flow Note) (l/min (ANR)) 1 8, , , , 3 50(2B) 80(3B) 0(4B) 0(4B) 4 3 4, 1 1, , 2 JIS K flange Mass (kg) Note) Max. flow at 0.7 MPa. Max. flow varies depending on the operating pressure. Refer to low Characteristics (page 15) and Maximum Air low below. Specifications luid Compressed air Max. operating pressure 1.0 MPa Min. operating pressure 0.05 MPa Proof pressure 1.5 MPa Ambient and fluid temperature 5 to 0 C Nominal filtration rating 3 µm (iltration efficiency: %) Element life 2 years (1 year for A type) or when pressure drop reached 0.1 MPa With auto drain: 0.1 MPa (N.O. type) or 0.15 MPa (N.C. type) Accessory/or 2C to 22C, 37B/75B Applicable model 2C 4C 8C 11C 22C 37B 75B Bracket assembly (with 2 mounting screws) -BM1 -BM2 -BM3 -BM4 -BM5 BM5 BM57 Accessory/or 75A to 2A Applicable model Auto drain (2 pcs. each) Pressure gauge (2 pcs. each) Companion flange (2 pcs. each) Anchor bolt (3 pcs. each) Selection Select a model in accordance with the following procedure taking the inlet pressure and the max. air flow rate into consideration. (Example) Inlet pressure: 0. MPa Max. air flow rate: 5 m 3 /min (ANR) 1. Obtain the intersecting point A of inlet pressure and max. air flow rate in the graph. 2. The 37B is obtained when the max. flow line is above the intersecting point A in the graph. 75A 125A 150A 2A 50(2B)JIS K flange AD G (3B)JIS K flange 0(4B)JIS K flange AI-2S Note) Make sure to select a model that has the max. flow line above the obtained intersecting point. With a model that has the max. flow line below the obtained intersecting point, the flow rate will be exceeded, thus leading to a problem such as being unable to satisfy the specifications. Maximum Air low Max. air flow rate (m 3 /min (ANR)) Inlet pressure (MPa) HAA HAW AT ID IDU IDA IDB ID IDG G D H E S SD LLB AD GD 153

14 MPa SMC MPa SMC Series How to Order 2C to 22C 2C 4C 8C 11C 22C Options 22C Body size Thread type Applicable compressor output (guide) Type 2.2 kw Nil Rc 3.7 kw G kw N NPT 11 kw 1 Conforms to 22 kw ISO Size Applicable body size Accessory 2C 4C 8C 11C 22C 1/8 Nil 1/4 B Bracket 2 3/8 2 Bracket is included, 1/2 (but not assembled). 3/4 3 The model with bracket is not available 1 for -X15 and -X17. Drain Exhaust Specifications/Option Combinations : All types of drain exhaust specifications are available. (including drain guide, J specification) : N.C. auto drain ( C specification) is not available. : Both N.C. and N.O. auto drain ( C, D specification) are not available. Nil H R S U T V Nil Note H R Note S U T V Note Note Note: Only one drain exhaust method can be selected. : Not available Made to Order ( How to Order and the applicable models are different from those shown on this page. Be sure to refer to Made to Order.) Nil X X15 X17 X2 Option 4 Nil H J R S U T V With differential pressure gauge (GD ) With - flange 3 With differential pressure gauge (GD ) and - flange 3 N.C., N.O. auto drain, drain piping type Rubber material: luororubber or medium air pressure (1. MPa) Drain guide 1/4 female threaded 5 - reversal direction Auto drain 4 Nil Drain cock (Without auto-drain) C N.C. auto drain D N.O. auto drain 4 Refer to Drain Exhaust Specifications/ Option Combinations. (Only one drain exhaust method can be selected.) Page for details P.211 P.212 P.212 P.213 With differential pressure switch (125 VAC, 30 VDC), Note) With differential pressure switch (30 VDC) With element service indicator Degreasing wash, 7 white vaseline 5 Drain piping and piping for a stop valve such as ball valve are required. Differential pressure gauge is included, (but not assembled). 7 Only body/housing is degreasing washed. Note) Order U if conformity to the EU directive is required. : Rubber material: luororubber luororubber is used for the parts such as O-ring and gasket. H: or medium air pressure (1. MPa) Can be used up to 1. MPa at maximum. J: Drain guide 1/4 female threaded 1/4 female thread Can be pipied to the drain exhaust port. R: - reversal direction Air flow in the separator is changed to right to left. (Air flow direction of the standard: Left to right.) T: With element service indicator Pressure drop 0.1 MPa Saturation of the separator can be observed visually. (Element life check) V: Degreasing wash, white vaseline Body/housing is degreasing washed. The lubrication grease for O-ring and gasket is changed to white vaseline. S: With differential pressure switch (with indicator) Saturation of the separator can be observed visually or by an electrical signal. (Element life check) The rated contact voltage is different from U. Max. contact capacity: VA AC, W DC Rated contact voltage (max. operating current): 125 V AC (0.08 A), 30 V DC (0.33 A) Reed switch U: With differential pressure switch (with indicator) Saturation of the separator can be observed visually or by an electrical signal. (Element life check) The rated contact voltage is different from S. Max. contact capacity: W DC Rated contact voltage (max. operating current): 30 V DC (0.33 A) Reed switch 154

15 Main Line ilter Series How to Order 37B/75B 37B 37B 75B Body size Applicable compressor output (guide) 37 kw 75 kw 14 75A to 2A Thread type Type Nil Rc G N NPT Size Applicable body size 37B 75B Accessory Nil B Bracket Bracket is included, (but not assembled). 2 The model with bracket is not available for -X15 and -X17. Auto Drain Specifications/Option Combinations Auto drain specifications Option Auto drain specifications/option 75A N.O. auto drain Drain guide reversal direction With element service indicator D Made to Order ( How to Order and the applicable models are different from those shown on this page. Be sure to refer to Made to Order.) Nil X With differential pressure gauge (GD ) With differential pressure switch (With indicator, X VAC, 30 VDC) X15 With - flange 2 With differential pressure gauge (GD ) X17 and - flange 2 X2 N.C., N.O. auto drain, drain piping type X12 White vaseline specifications Option 3 Nil J Drain guide 1 4 female threaded 5 R - reversal direction T With element service indicator 5 Drain piping and piping for a stop valve such as ball valve are required. Auto drain 3 Nil Drain cock (Without auto drain) 4 D N.O. auto drain 3 Refer to Auto Drain Specifications/Option Combinations. 4 Body size 75B is equipped with a ball valve (Rc 3/8 female threaded). Mount a piping adapter ID-AP0 (page 5) to the ball valve if NPT 3/8 female threaded is required. D J R T Page for details P.211 P.211 P.212 P.212 P.213 P.213 Note) Refer to How to Order Bowl Assembly on page. : Available : Not available Auto drain specifications Option Applicable model D J R T 37B 75B HAA HAW AT ID IDU IDA IDB ID IDG G D H E S SD LLB AD GD Standard size (Applicable compressor) Compressor output 75A 75 kw 125A 1 to 125 kw 150A 150 kw 2A 180 to 2 kw Size 50(2B) JIS K flange 80(3B) JIS K flange 0(4B) JIS K flange Applicable body size 75A 125A 150A 2A Made to Order ( How to Order and the applicable models are different from those shown on this page. Be sure to refer to Made to Order.) Nil Page for details X13 Mist separator for high flow rate (Nominal filtration rating: 0.3 µm) P.214 Accessory Nil D Auto drain G Pressure gauge Companion flange L Anchor bolt 155

16 Series low Characteristics (Representative values)/select the model taking the max. flow capacity into consideration. (Element oil saturation) Note) Compressed air over max. flow line in the table below may not meet the specifications of the product. 2C 22C 75A Air flow rate (l/min (ANR)) Air flow rate (l/min (ANR)) Air flow rate (m 3 /min (ANR)) 4C 37B 125A Air flow rate (l/min (ANR)) Air flow rate (l/min (ANR)) Air flow rate (m 3 /min (ANR)) 8C 75B 150A Air flow rate (l/min (ANR)) Air flow rate (m 3 /min (ANR)) Air flow rate (m 3 /min (ANR)) 11C 2A 15 Air flow rate (l/min (ANR)) Air flow rate (m 3 /min (ANR))

17 Main Line ilter Series Construction 2C to 22C, 37B 75B q Replacement Parts No. 4 r w Component Parts No. Material Note Body Housing Sight glass Aluminum die-casted Aluminum die-casted Tempered glass Chrome treated Epoxy coating on inner surface The 75B is aluminum casted. Element assembly Material Cotton paper, others Element assembly: With gasket (1 pc.) and O-ring (1 pc.) Refer to page 21 for replacement of auto drain. Element assemblies for Made to Order (X, X12, X15, X17, X2, X37) are same as those for standard (see the above table). 75A to 2A Applicable model Except option or option 2C -EL2B -EL2B- e 4C -EL4B -EL4B- 8C -EL8B -EL8B- Note) Refer to How to Order Bowl Assembly on page. Note) Sight glass is indicated in the figure for easy understanding of component parts. However, it differs from the actual construction. Please refer to pages 158 through to 10 for details. 11C -EL11B -EL11B- 22C -EL22B -EL22B- 37B -EL37B 75B -EL75B HAA HAW AT ID IDU IDA IDB ID IDG G D H E S SD LLB AD GD ( side) Guage port Drain Gauge port ( side) Component Parts No. 1 2 Case Cover Material SGP-E, SS400 SS400 Note Drain Replacement Parts No. Material Qty. 3 Element 4 Seal NBR A 125A 150A 2A EC N EC N EC00-003N AL-33S AL-34S AL-35S 157

18 Series Dimensions 2C to 22C P Q Auto drain C: With auto drain (N.C.) D: With auto drain (N.O.) Drain cock Gray: N.C. Black: N.O. 34 O ø One-touch fitting S, U: With differential pressure switch (with indicator) Y Z T: With element service indicator W X R S Combination of D: With auto drain (N.O.) and H: or medium air pressure K U T D I L M øv Bracket (Accessory) N Note) 1/4 female threaded Note) 23 for 4C. Width across flats 17 H C J A E B Option J: Drain guide 1/4 female threaded Width across flats 24 1/4 female threaded G Maintenance space Drain port M5 2C 4C 8C 11C 22C 158 1/8, 1/4 1/4, 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 A B C D E G 15 H I J K T 7 Bracket related dimensions U 7 L M 7 V N O P Q R S (mm) Element Differential service pressure indicator related switch related dimensions dimensions W X Y Z

19 Main Line ilter Series Dimensions 37B Auto drain D: With auto drain (N.O.) Drain cock: Black HAA HAW ø One-touch fitting 34 AT ID IDU IDA Option J: Drain guide 1/4 female threaded IDB ID 10 IDG Bracket (Accessory) 85 G Width across flats 24 1/4 female threaded D T: With element service indicator H E S SD 23 LLB Maintenance space Drain port M5 AD GD 15

20 Series Dimensions 75B Auto drain D: With auto drain (N.O.) for 75B Bracket (Accessory) 1 Option T: With element service indicator /8 female threaded Maintenance space Drain Rc 3/8 female threaded 75A to 2A 3 x ø holes or foundation bolt Label Drain ORIENTATION 10 Drain (mm) øa B C D E G 75A 125A 150A 50(2B)JISK flange 80(3B)JISK flange 0(4B)JISK flange 0 (8B) 0 (8B) 250 (B) A 0(4B)JISK flange 300 (12B)

21 Mist Separator Series RoHS Can remove oil mist in compressed air and separate and remove particles such as rust or carbon of more than 0.3 µm. Modular connection is possible with 150C to 550C. (or details, refer to page 4.) 150C to 550C (Drain cock specifications) 50/850 (Auto drain specifications) Made to Order (or details, refer to page 2.) 150C 250C 350C 450C 550C Note) Rated flow (l/min (ANR)) , , , , , 1 1, , 2 Mass (kg) Note) Max. flow at 0.7 MPa. Max. flow varies depending on the operating pressure. Refer to low Characteristics (page 14) and Maximum Air low (page 15). Note) Refer to Made to Order (page 214) for high flow type of 850 or more. Specifications luid Max. operating pressure Min. operating pressure 1 Proof pressure Ambient and fluid temperature Nominal filtration rating Oil mist density at outlet Element life 1 With auto drain: 0.1 MPa (N.O. type) or 0.15 MPa (N.C. type) 2 Oil mist density at 30 mg/m 3 (ANR) blown out by compressor. Accessory Applicable model Bracket assembly (with 2 mounting screws) Caution Compressed air 1.0 MPa 0.05 MPa 1.5 MPa 5 to 0 C 0.3 µm (iltration efficiency:.%) Max. 1 mg/m 3 (ANR) ( 0.8 ppm) 2 2 years or when pressure drop reached 0.1 MPa 150C 250C 350C 450C 550C BM1 -BM2 -BM3 -BM4 -BM5 BM5 BM57 Be sure to read before handling. Refer to front matters 42 and 43 for Safety Instructions and pages to 8 for Air Preparation Equipment Precautions. HAA HAW AT ID IDU IDA IDB ID IDG G D H E S SD LLB AD GD 11

22 SMC MPa SMC MPa Series 150C to 550C 150C 250C 350C 450C 550C Options Body size Applicable compressor output (guide) 2.2 kw 3.7 kw 7.5 kw 11 kw 22 kw 1/8 1/4 3/8 1/2 3/ C Thread type Type Nil Rc G 1 N NPT 1 Conforms to ISO Applicable body size Size 150C 250C 350C 450C 550C Nil B Bracket 2 2 Bracket is included, (but not assembled). 3 The model with bracket is not available for -X15 and -17. Nil H R S U T V Nil Note H R Note S U T V Note Note Note: Only one drain exhaust method can be selected. : Not available How to Order Accessory Drain Exhaust Specifications/Option Combinations : All types of drain exhaust specifications are available. (including drain guide, J specification) : N.C. auto drain ( C specification) is not available. : Both N.C. and N.O. auto drain ( C, D specification) are not available. Nil X X15 X17 X2 Option 4 Nil H J R S U T V Made to Order ( How to Order and the applicable models are different from those shown on this page. Be sure to refer to Made to Order.) With differential pressure gauge (GD ) With - flange With differential pressure gauge (GD ) and - flange 3 N.C., N.O. auto drain, drain piping type Rubber material: luororubber or medium air pressure (1. MPa) Drain guide 1/4 female threaded 5 - reversal direction With differential pressure switch (125 VAC, 30 VDC), Note) With differential pressure switch (30 VDC) Element service indicator Degreasing wash, 7 white vaseline 5 Drain piping and piping for a stop valve such as ball valve are required. Differential pressure gauge is included, (but not assembled). 7 Only body/housing is degreasing washed. Note) Order U if conformity to the EU directive is required. Auto drain 4 Nil Drain cock (Without auto drain) C N.C. auto drain D N.O. auto drain 4 Refer to Drain Exhaust Specifications/ Option Combinations. (Only one drain exhaust method can be selected.) Page for details P.211 P.212 P.212 P.213 : Rubber material: luororubber luororubber is used for the parts such as O-ring and gasket. H: or medium air pressure (1. MPa) Can be used up to 1. MPa at maximum. J: Drain guide 1/4 female threaded Can be pipied to the drain exhaust port. 1/4 female threaded R: - reversal direction Air flow in the separator is changed to right to left. (Air flow direction of the standard: Left to right.) T: With element service indicator Pressure drop 0.1 MPa Saturation of the separator can be observed visually. (Element life check) V: Degreasing wash, white vaseline Body/housing is degreasing washed. The lubrication grease for O-ring and gasket is changed to white vaseline. S: With differential pressure switch (with indicator) Saturation of the separator can be observed visually or by an electrical signal. (Element life check) The rated contact voltage is different from U. Max. contact capacity: VA AC, W DC Rated contact voltage (max. operating current): 125 V AC (0.08 A), 30 V DC (0.33 A) Reed switch U: With differential pressure switch (with indicator) Saturation of the separator can be observed visually or by an electrical signal. (Element life check) The rated contact voltage is different from S. Max. contact capacity: W DC Rated contact voltage (max. operating current): 30 V DC (0.33 A) Reed switch 12

23 Mist Separator Series How to Order 50/ Body size Applicable compressor output (guide) kw kw Size Thread type Type Nil Rc G N NPT Applicable body size Accessory Nil B Bracket 1 1 Bracket is included, (but not assembled). 2 The model with bracket is not available for -X15 and -X17. Auto Drain Specifications/Option Combinations Auto drain specifications Option Auto drain specifications/option N.O. auto drain Drain guide reversal direction With element service indicator Made to Order ( How to Order and the applicable models are different from those shown on this page. Be sure to refer to Made to Order.) Nil X With differential pressure gauge (GD ) With differential pressure switch (With indicator, X VAC, 30 VDC) X15 With - flange 2 With differential pressure gauge (GD ) X17 and - flange 2 X2 N.C., N.O. auto drain, drain piping type X12 White vaseline specifications Option 3 Nil J Drain guide 1 4 female threaded 5 R - reversal direction T With element service indicator 5 Drain piping and piping for a stop valve such as ball valve are required. Auto drain 3 Nil Drain cock (Without auto drain) 4 D N.O. auto drain 3 Refer to Auto Drain Specifications/Option Combinations. 4 Body size 850 is equipped with a ball valve (Rc 3/8 female threaded). Mount a piping adapter ID-AP0 (page 5) to the ball valve if NPT 3/8 female threaded is required. D J R T Page for details P.211 P.211 P.212 P.212 P.213 P.213 Note) Refer to How to Order Bowl Assembly on page. : Available : Not available Auto drain specifications Option Applicable model D J R T HAA HAW AT ID IDU IDA IDB ID IDG G D H E S SD LLB AD GD 13

24 Series low Characteristics (Representative values) (Element oil saturation) Note) Compressed air over max. flow line in the table below may not meet the specifications of the product. 150C 450C 850 Air flow rate (l/min (ANR)) Air flow rate (l/min (ANR)) Air flow rate (m 3 /min (ANR)) 250C 550C Air flow rate (l/min (ANR)) Air flow rate (l/min (ANR)) 350C 50 Air flow rate (l/min (ANR)) Air flow rate (l/min (ANR)) 14

25 Mist Separator Series Construction 150C to 550C, q r w Component Parts No. Material Note Body Housing Sight glass Aluminum die-casted Aluminum die-casted Tempered glass Chrome treated Epoxy coating on inner surface The 850 is aluminum casted. Replacement Parts No. 4 Maximum Air low Max. air flow rate (m 3 /min (ANR)) Element assembly Material Glass fiber, others Applicable model Except option or option 150C -EL150 -EL150- e 250C -EL250 -EL250- Element assembly: With gasket (1 pc.) and O-ring (1 pc.) Refer to page 21 for replacement of auto drain. Element assemblies for Made to Order (X, X12, X15, X17, X2, X37) are same as those for standard (see the above table). 350C -EL350 -EL350- Note) Refer to How to Order Bowl Assembly on page. Note) Sight glass is indicated in the figure for easy understanding of component parts. However, it differs from the actual construction. Refer to dimensions on pages 1 through to 18 for details. 450C -EL450 -EL450- Selection 550C -EL550 -EL EL EL850 Select a model in accordance with the following procedure taking the inlet pressure and the max. air flow rate into consideration. (Example) Inlet pressure: 0. MPa Max. air flow rate: 5 m 3 /min (ANR) 1. Obtain the intersecting point A of inlet pressure and max. air flow rate in the graph. 2. The 50 is obtained when the max. flow line is above the intersecting point A in the graph. Note) Make sure to select a model that has the max. flow line above the obtained intersecting point. With a model that has the max. flow line below the obtained intersecting point, the flow rate will be exceeded, thus leading to a problem such as being unable to satisfy the specifications. HAA HAW AT ID IDU IDA IDB ID IDG G D H E S SD LLB AD GD Inlet pressure (MPa) 15

26 Series Dimensions 150C to 550C P Q Auto drain C: With auto drain (N.C.) D: With auto drain (N.O.) Drain cock Gray: N.C. Black: N.O. 34 O ø One-touch fitting S, U: With differential pressure switch (with indicator) Y Z T: With element service indicator W X R S Combination of D: With auto drain (N.O.) and H: or medium air pressure K U T D I L M øv Bracket (Accessory) N Note) 1/4 female threaded Note) 23 for 250C. Width across flats 17 H C J A E B Option J: Drain guide 1/4 female threaded Width across flats 24 1/4 female threaded G Maintenance space Drain port M5 150C 250C 350C 450C 550C 1 1/8, 1/4 1/4, 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 A B C D E G 15 H I J K T 7 Bracket related dimensions U 7 L M 7 V N O P Q R S (mm) Element Differential service pressure indicator related switch related dimensions dimensions W X Y Z

27 Mist Separator Series Dimensions 50 Auto drain D: With auto drain (N.O.) Drain cock: Black HAA HAW ø One-touch fitting 34 AT ID IDU IDA Option IDB J: Drain guide 1/4 female threaded ID 10 IDG Bracket (Accessory) 85 G Width across flats 24 1/4 female threaded D T: With element service indicator H E S SD 23 LLB Maintenance space Drain port M5 AD GD 17

28 Series Dimensions 850 Auto drain D: With auto drain (N.O.) for Bracket 2 (Accessory) /8 female threaded Option 13 T: With element service indicator 30 Maintenance space Drain Rc 3/8 female threaded 18

29 Micro Mist Separator Series D RoHS Can separate and remove aerosol state oil mist in compressed air and remove particles such as carbon or dust of more than 0.01 µm. Use this product as a pre-filter for compressed air for precision instruments or clean room requiring higher clean air. Modular connection is possible with D150C to 550C. (or details, refer to page 4.) D150C to 550C D (Drain cock specifications) D50/850 D (Auto drain specifications) Made to Order (or details, refer to page 2.) D150C D250C D350C D450C D550C D50 Note) Rated flow (l/min (ANR)) Mass (kg) 1 8, , , , , 1 D Note) Max. flow at 0.7 MPa. Max. flow varies depending on the operating pressure. Refer to low Characteristics (page 172) and Maximum Air low (page 171). /ree Standing Type D800 D00 D00 Rated flow (l/min (ANR)) (2B)JIS 50(2B), 80(3B), 0(4B)JIS 0(4B), 150(B)JIS K flange K flange K flange Mass (kg) /Piping Support Type D801 Rated flow (l/min (ANR)) (2B)JIS K flange Mass (kg) 50 Specifications luid Max. operating pressure Min. operating pressure 1 Proof pressure Ambient and fluid temperature Nominal filtration rating Oil mist density at outlet Element life 1 With auto drain: 0.1 MPa (N.O. type) or 0.15 MPa (N.C. type) 2 Oil mist density at 30 mg/m 3 (ANR) blown out by compressor. Accessory Applicable model Bracket assembly (with 2 mounting screws) 1, , 2 D (2B), 80(3B), 0(4B)JIS K flange 140 Compressed air 1.0 MPa 0.05 MPa 1.5 MPa 5 to 0 C 0.01 µm (iltration efficiency:.%) Max. 0.1 mg/m 3 (ANR) 2 (Before saturated with oil, less than 0.01 mg/m 3 (ANR) ppm) 2 years (1 year for flange type) or when pressure drop reached 0.1 MPa D150C D250C D350C D450C D550C D50 D850 -BM1 -BM2 -BM3 -BM4 -BM5 BM5 BM57 HAA HAW AT ID IDU IDA IDB ID IDG G D H E S SD LLB AD GD Caution Be sure to read before handling. Refer to front matters 42 and 43 for Safety Instructions and pages to 8 for Air Preparation Equipment Precautions. 1

30 SMC MPa SMC MPa Series D D150C to 550C Body size 150C 250C 350C 450C 550C /8 1/4 3/8 1/2 3/4 1 Options D 550C Thread type Type Nil Rc G 1 N NPT 1 Conforms to ISO Applicable body size Size 150C 250C 350C 450C 550C Accessory Nil B Bracket 2 2 Bracket is included, (but not assembled). 3 The model with bracket is not available for -X15 and -X17. Drain Exhaust Specifications/Option Combinations : All types of drain exhaust specifications are available. (including drain guide, J specification) : N.C. auto drain ( C specification) is not available. : Both N.C. and N.O. auto drain ( C, D specification) are not available. Nil H R S U T V Note Nil H R S U T V Note Note Note Note: Only one drain exhaust method can be selected. : Not available How to Order Made to Order ( How to Order and the applicable models are different from those shown on this page. Be sure to refer to Made to Order.) Nil X X15 X17 X2 With differential pressure gauge (GD ) With - flange 3 With differential pressure gauge (GD ) and - flange 3 N.C., N.O. auto drain, drain piping type Option 4 Nil Rubber material: luororubber H or medium air pressure (1. MPa) J Drain guide 1/4 female thread 5 R - reversal direction S With differential pressure switch (125 VAC, 30 VDC), Note) U With differential pressure switch (30 VDC) T With element service indicator V Degreasing wash, 7 white vaseline 5 Drain piping and piping for a stop valve such as ball valve are required. Differential pressure gauge is included, (but not assembled). 7 Only body/housing is degreasing washed. Note) Order U if conformity to the EU directive is required. Auto drain 4 Nil Drain cock (Without auto drain) C N.C. auto drain D N.O. auto drain 4 Refer to Drain Exhaust Specifications/ Option Combinations. (Only one drain exhaust method can be selected.) Page for details P.211 P.212 P.212 P.213 : Rubber material: luororubber luororubber is used for the parts such as O-ring and gasket. H: or medium air pressure (1. MPa) Can be used up to 1. MPa at maximum. J: Drain guide 1/4 female threaded Can be pipied to the drain exhaust port. 1/4 female threaded R: - reversal direction Air flow in the separator is changed to right to left. (Air flow direction of the standard: Left to right.) T: With element service indicator Pressure drop 0.1 MPa Saturation of the separator can be observed visually. (Element life check) V: Degreasing wash, white vaseline Body/housing is degreasing washed. The lubrication grease for O-ring and gasket is changed to white vaseline. S: With differential pressure switch (with indicator) Saturation of the separator can be observed visually or by an electrical signal. (Element life check) The rated contact voltage is different from U. Max. contact capacity: VA AC, W DC Rated contact voltage (max. operating current): 125 V AC (0.08 A), 30 V DC (0.33 A) Reed switch U: With differential pressure switch (with indicator) Saturation of the separator can be observed visually or by an electrical signal. (Element life check) The rated contact voltage is different from S. Max. contact capacity: W DC Rated contact voltage (max. operating current): 30 V DC (0.33 A) Reed switch 170

31 Micro Mist Separator Series D How to Order D50/850 D 50 Body size ree standing type D800/8 to 0 Piping support type D 8 00 D 8 01 Body size 8 Type 00 With manual drain cock With auto drain Selection Thread type Type Nil Rc G N NPT Size Applicable body size Accessory Nil B Bracket 1 1 Bracket is included, (but not assembled). 2 The model with bracket is not available for -X15 and -X17. Auto drain 3 Nil Drain cock (Without auto drain) 4 D N.O. auto drain 3 Refer to Auto Drain Specifications/Option Combinations. 4 Body size 850 is equipped with a ball valve (Rc 3/8 female threaded). Mount a piping adapter ID-AP0 (page 5 ) to the ball valve if NPT 3/8 female threaded is required. Applicable body size Size D800, 8 D 0 D 0 50(2B)JIS K flange 80(3B)JIS K 30 flange 0(4B)JIS K 40 flange 150(B)JIS K 0 flange Select a model in accordance with the following procedure taking the inlet pressure and the max. air flow rate into consideration. (Example) Inlet pressure: 0. MPa Max. air flow rate: 5 m 3 /min (ANR) 1. Obtain the intersecting point A of inlet pressure and max. air flow rate in the graph. 2. The D50 is obtained when the max. flow line is above the intersecting point A in the graph. Note) Make sure to select a model that has the max. flow line above the obtained intersecting point. With a model that has the max. flow line below the obtained intersecting point, the flow rate will be exceeded, thus leading to a problem such as being unable to satisfy the specifications. Option 3 Nil J Drain guide 1 4 female threaded 5 R - reversal direction T With element service indicator 5 Drain piping and piping for a stop valve such as ball valve are required. Auto drain specifications/option Body size 8 Nil X X37 X15 X17 X2 X12 Auto drain specifications N.O. auto drain Drain guide 1 4 Option - reversal direction With element service indicator Type 01 With manual drain cock 11 With auto drain Maximum Air low Made to Order ( How to Order and the applicable models are different from those shown on this page. Be sure to refer to Made to Order.) D 0 D 0, 1 D850 D80, 81 D50 D550C D450C D350C D250C With differential pressure gauge (GD ) With differential pressure switch (With indicator, 125 VAC, 30 VDC) With - flange 2 With differential pressure gauge (GD ) and - flange 2 N.C., N.O. auto drain, drain piping type White vaseline specifications D J R T Auto drain specifications Option D J R T Page for details P.211 P.211 P.212 P.212 P.213 P.213 Auto Drain Specifications/ Option Combinations : Available : Not available Max. air flow rate (m 3 /min (ANR)) D801/811/ 1 Note) Refer to How to Order Bowl Assembly on page. Size 50(2B)JIS K flange 80(3B)JIS K 30 flange 0(4B)JIS K 40 flange Applicable model D50 D850 Applicable body size D8 1 D 1 HAA HAW AT ID IDU IDA IDB ID IDG G D H E S SD LLB AD GD D150C Inlet pressure (MPa) 171

32 Series D low Characteristics (Representative values)/select the model taking the max. flow capacity into consideration. ( Element oil saturation Initial condition) Note) Compressed air over max. flow line in the table below may not meet the specifications of the product. D150C D550C D 0/ 1 Air flow rate (l/min (ANR)) Air flow rate (l/min (ANR)) Air flow rate (m 3 /min (ANR)) D250C D50 D 0 D350C Air flow rate (l/min (ANR)) D80 /81 Air flow rate (l/min (ANR)) Air flow rate (m 3 /min (ANR)) D450C Air flow rate (l/min (ANR)) D850 Air flow rate (m 3 /min (ANR)) 172 Air flow rate (l/min (ANR)) Air flow rate (m 3 /min (ANR))

33 Micro Mist Separator Series D Construction D150C to 550C, D50 q D850 Replacement Parts No. 4 r w Component Parts No. Material Note Body Housing Sight glass Aluminum die-casted Aluminum die-casted Tempered glass Chrome treated Epoxy coating on inner surface The D850 is aluminum casted. Element assembly Material Glass fiber, others Applicable model Except option or option D80 /81 / 0/ 1/ 0 D150C D-EL150 D-EL150- e D250C D-EL250 D-EL250- D350C D-EL350 D-EL350- Element assembly: With gasket (1 pc.) and O-ring (1 pc.) Refer to page 21 for replacement of auto drain. Element assemblies for Made to Order (X, X12, X15, X17, X2, X37) are same as those for standard (see the above table). Note) Refer to How to Order Bowl Assembly on page. Note) Sight glass is indicated in the figure for easy understanding of component parts. However, it differs from the actual construction. Refer to dimensions on pages 174 through to 177 for details. D450C D-EL450 D-EL450- D550C D-EL550 D-EL550- D50 D-EL50 D850 D-EL850 HAA HAW AT ID IDU IDA IDB ID IDG G D H E S SD LLB AD GD Element Component Parts/Material No. 1 ilter case 2 Cover Replacement Parts No. 3 Element 4 Seal 5 Seal Material NBR NBR D800/8/ 0/ 0 D801/811/ 1 SGP-E, SS400 SGP-E, SS400 SS400 SGP-E, SS400 D800/8 D801/811 D 0 D 1 D pcs pcs pcs pcs pcs pcs. O.D112 x I.D0 x T3 O.D112 x I.D0 x T3 3 pcs. O.D112 x I.D0 x T3 5 pcs. Drain Gasket V#500 AL-1S AL-0S AL-3S AL-2S AL-31S 7 O-ring NBR JIS B2401G35 1 pc. JIS B2401G35 1 pc. JIS B2401G35 3 pcs. JIS B2401G35 3 pcs. JIS B2401G35 5 pcs. 173

34 Series D Dimensions D150C to 550C P Q Auto drain C: With auto drain (N.C.) D: With auto drain (N.O.) Drain cock Gray: N.C. Black: N.O. 34 O ø One-touch fitting S, U: With differential pressure switch (with indicator) Y Z T: With element service indicator W X R S Combination of D: With auto drain (N.O.) and H: or medium air pressure K U T D I L M øv Bracket (Accessory) N Note) 1/4 female threaded Note) 23 for D250C. Width across flats 17 H C J A E B Option J: Drain guide 1/4 female threaded Width across flats 24 1/4 female threaded G Maintenance space Drain port M5 D150C D250C D350C D450C D550C 174 1/8, 1/4 1/4, 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 A B C D E G 15 H I J K T 7 Bracket related dimensions U 7 L M 7 V N O P Q R S (mm) Element Differential service pressure indicator related switch related dimensions dimensions W X Y Z

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications Speed Controller with One-touch Fitting Stainless Steel Series Elbow Type/Universal Type Series -FG RoHS Stainless specifications for use in corrosive environments. Stainless steel used for metal parts.

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

Series IDU/IDF. Refrigerated Air Dryer

Series IDU/IDF. Refrigerated Air Dryer Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In

More information

Compressed Air Filters

Compressed Air Filters Compressed Air Filters Superior Filtration for Increased Productivity What happens when you don t use an air filter? Kaeser Gives You the Air Quality You Require Ambient air contains contaminants that

More information

Valve systems Base plates, according to standard ISO 5599-1. Brochure

Valve systems Base plates, according to standard ISO 5599-1. Brochure ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS Oil Free Scroll Compressors are constantly evolving ANEST IWATA was the first manufacturer to introduce Oil Free Scroll Compressors in 1991 and has kept

More information

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators Condensate Treatment Solutions CTS Series Eliminator II Oil-Water Separators 2 Condensate Treatment Solutions A Cleaner Environment & Reduced Disposal Costs Compressed air is compressed and discharged

More information

Dryaire Desiccant System

Dryaire Desiccant System Instructions/Parts Dryaire Desiccant System 310595F Model 6760 Maximum Operating Pressure: 160 PSI (1.1 MPa, 11 bar) System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

15/40/80CN Series Medium Pressure Filters

15/40/80CN Series Medium Pressure Filters 1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)

More information

Atlas Copco Quality Air Solutions. Compressed Air Filters

Atlas Copco Quality Air Solutions. Compressed Air Filters Atlas Copco Quality Air Solutions Compressed Air Filters Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air for superior operational

More information

Kompressoren. Oil Water Separators OWS

Kompressoren. Oil Water Separators OWS Kompressoren Oil Water Separators OWS Removal Of Contaminants in Compressed Air Condensate. Atmospheric air contains large amounts of water vapour and dust particles. These contaminants are mixed with

More information

ThermoSorb Desiccant Dryers

ThermoSorb Desiccant Dryers ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression

More information

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

6 Crankcase Ventilation

6 Crankcase Ventilation 6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................

More information

Port Size M5 1 Rc Autodrain available New super efficient 5µm Poly-element Quick release bowl guard on some sizes High flow

Port Size M5 1 Rc Autodrain available New super efficient 5µm Poly-element Quick release bowl guard on some sizes High flow A IR PREPARATION 5.7 A IR FILTER SERIES AF AF000 2000 Port Size M5 Rc Autodrain available New super efficient 5µm Poly-element Quick release bowl guard on some sizes High flow Model AF000 AF2000 AF000

More information

How To Remove A Large Particle From A Large Tank

How To Remove A Large Particle From A Large Tank Delta Series Premium Filters www.numatics.com Table of Contents Delta Series Features and Benefits 3 Science of Coalescing Filtration 4 Water Separator 5 How to Order - Water Separator 6 Pressure and Temperature

More information

Refrigeration Compressed Air Dryer Buran Ultrapulse

Refrigeration Compressed Air Dryer Buran Ultrapulse Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of

More information

ETC -SV. Class 0 oil-free compressed air through catalysis

ETC -SV. Class 0 oil-free compressed air through catalysis Innovation QUALITy Reliability Worldwide ETC -SV Class 0 oil-free compressed air through catalysis The way to oil-free compressed air The ETC operating principle Through the process of catalytic oxidation,

More information

In-Line Filters and Coalescers with Automatic Drains

In-Line Filters and Coalescers with Automatic Drains Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: 31 3362-2400 w.tecni-ar.com.br

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: 31 3362-2400 w.tecni-ar.com.br OIL-X EVOLUTION ENGINEERING YOUR SUCCESS. OIL-X EVOLUTION High Efficiency Compressed Air Filtration OIL-X EVOLUTION is a range of high efficiency compressed air filters consisting of coalescing filter

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

G1/4 Q8. Standard with biased position

G1/4 Q8. Standard with biased position Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,

More information

CAT.ES120-4 A. Precision Clean Regulator. Series SRP. High precision, low flow consumption stainless steel regulator

CAT.ES120-4 A. Precision Clean Regulator. Series SRP. High precision, low flow consumption stainless steel regulator CAT.ES120-4 A Precision Clean Regulator Series SRP High precision, low flow consumption stainless steel regulator Precision Clean Regulator Series SRP High precision, low flow consumption stainless steel

More information

Control blocks for two-hand start ZSB

Control blocks for two-hand start ZSB Key features Function This pneumatic control block for twohand start ZSB is used where a manually started operation, such as the triggering of compressed air cylinders, would otherwise involve danger for

More information

15/40/80CN Series Coreless Medium Pressure Filters

15/40/80CN Series Coreless Medium Pressure Filters //8CN Series Coreless Medium Pressure Filters //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment Pilot

More information

How To Use A Ds340 (Dsp)

How To Use A Ds340 (Dsp) Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

DIESEL FUEL CONDITIONING

DIESEL FUEL CONDITIONING COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency

More information

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8 * U S 4 Specifications escriptions Bore size mm Actuation Working fluid ax. working pressure Pa in. working pressure Pa Withstanding pressure Pa Ambient temperature Port size Stroke length Rubber cushioned

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

Wear Resistant Tubing

Wear Resistant Tubing Wear Resistant Tubing 1/ brasion: pprox. (Compared with SMC polyurethane tubing TU series) 3 6-color variations Description Wear resistant tubing TUZ series Polyurethane tubing TU series Green RoHS Maximum

More information

Ultra-Filter. Compressed Air Filter. DF Series

Ultra-Filter. Compressed Air Filter. DF Series Ultra-Filter DF Series ié~çáåö=íüé=t~ó=áå=^áê=mìêáñáå~íáçå As one of the world s leading manufacturers of compressed air purification equipment, Donaldson has built a comprehensive engineering, manufacturing,

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3

More information

CSD WATER REMOVAL FILTERS FOR DIESEL

CSD WATER REMOVAL FILTERS FOR DIESEL CSD CSD WATER REMOVAL FILTERS FOR DIESEL Remove water to extend fuel injector life & increase combustion fuel efficiency Remove free water to saturation point with high single pass efficienc (achieve

More information

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

Membrane air dryers MS-LDM1, MS series

Membrane air dryers MS-LDM1, MS series Membrane air dryers MS-LDM1, MS series Membrane air dryers MS-LDM1, MS series Product range overview MS series service units Type Size Pressure regulation range [bar] Grade of filtration [μm] Pneumatic

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

Service units MSB-FRC, MS series

Service units MSB-FRC, MS series Service units MSB-FRC, MS series Service units MSB-FRC, MS series Product range overview MS series service units Type Size Pressure regulation range [bar] Grade of filtration [µm] Pneumatic connection

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

Self Purging Liquid Trap (SPLT ) User s Manual

Self Purging Liquid Trap (SPLT ) User s Manual Self Purging Liquid Trap (SPLT ) User s Manual High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

Adsorption air dryers ADS 1 215

Adsorption air dryers ADS 1 215 Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

Thermostatic valve Type AVTA

Thermostatic valve Type AVTA MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The

More information

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

ThermoStar Refrigeration Air Dryers

ThermoStar Refrigeration Air Dryers ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems

More information

OEM-EP Pressure Controllers

OEM-EP Pressure Controllers Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems 185, 600, 1200, 1800, 2700 Series Portable Purification Systems FEATURING Global Filtration Technology PRINCIPLES OF OPERATION Contaminated oil is drawn into the Parker Portable Purification System by

More information

NORMAN FILTER COMPANY PRODUCT OVERVIEW

NORMAN FILTER COMPANY PRODUCT OVERVIEW NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100

More information

Filter Housing SG Standard

Filter Housing SG Standard Page of 7 Filter Housing SG Standard The steel standard filter housings with econometer and pneumatic drain are designed for the purification of compressed air and gases. Due to the modular design of the

More information

Model 43AP Pneumatic Controller, Style B

Model 43AP Pneumatic Controller, Style B Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set

More information

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL) HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL) The oil level regulator controls the oil level in the compressor crankcase with a float operated valve. Oil level regulators are designed to attach

More information

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED General Air Type P Hydryer Heat Regenerative Systems Introduction General Air Type P Hydryers are electric heat regenerative dryers, designed

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING PREMIUM HIGH-PRESSURE DRYING HIGH QUALITY COMPRESSED AIR FROM BEKO The quality of your compressed air. RELIABLE The highest level of operational reliability is guaranteed with every product that BEKO manufactures.

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Backflush filter R8-30W

Backflush filter R8-30W Backflush filter R8-30W With internal pressure segment cleaning, rated pressure to 40 bar (580 psi) Connection sizes: DN 200 to DN 500, welded design 1. Features Powerful, fully automatic filtration _

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999 CONTAMINATION CONTROL in hydraulic systems in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further information.

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications: E X T E N D I N G Y O U R E N E R G Y DIESEL & JET FUEL FILTRATION EQUIPMENT Applications: Back-Up Diesel Generators Gas Turbines Fueling Terminals for Trucks & Buses Marine Mining Railroad Agriculture

More information

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc. ISO-9001:2000 certified EE300 Series Electromechanical Inventory Level Measuring System Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION OPERATING PRINCIPLE The EE300 series level measuring system is a

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

How To Order A Direct Flow Air Cleaner

How To Order A Direct Flow Air Cleaner Reduced Volume - Improved Performance - Flexible Packaging The patented Direct Flow technology provides the flexibility to optimize the air system performance to size ratio, meeting the demands of today

More information

Direct steam injection humidifiers

Direct steam injection humidifiers Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature

More information

Basic Hydraulics and Pneumatics

Basic Hydraulics and Pneumatics Basic Hydraulics and Pneumatics Module 1: Introduction to Pneumatics PREPARED BY IAT Curriculum Unit March 2011 Institute of Applied Technology, 2011 ATM 1122 Basic Hydraulics and Pneumatics Module 1:

More information

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Shut-off & Lockout Valves 1/4 to 1-1/2 port size Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information