Port Size M5 1 Rc Autodrain available New super efficient 5µm Poly-element Quick release bowl guard on some sizes High flow

Size: px
Start display at page:

Download "Port Size M5 1 Rc Autodrain available New super efficient 5µm Poly-element Quick release bowl guard on some sizes High flow"

Transcription

1 A IR PREPARATION 5.7 A IR FILTER SERIES AF AF Port Size M5 Rc Autodrain available New super efficient 5µm Poly-element Quick release bowl guard on some sizes High flow Model AF000 AF2000 AF000 AF4000 AF5000 AF6000 Port size M5x Flow rate ln/min* AF Max. supply pressure ar Max. operating pressure ar Ambient and media temperature 5 ~ 60 C Filtration Standard: 5µm owl material Min. operating condition for autodrain type * 7 bar supply, Pressure drop P = 0.5 bar * Flow data is for new Poly-Element owl capacity cm Min. flow 00 nl/min Min Pressure ar AF AIR FILTER 000 M AF AUTODRAIN Nil Without D With M5 M AIR FILTER Poly Filter Sintered ronze Applicable Element Filter Element 5µm Filter Series AF A AF A AF000 60A AF A AF A AF6000 Note: Sintered bronze and Poly-elements are not interchangable AF AF AF AF5000/6000 Model A C D E F G H J K L M P With Auto Drain AF Differential pressure AF Differential pressure AF Float AF Float AF Float AF Float S Y M O L S ORDER LINES Castle Hill NSW...Tel: (02) Fax: (02) SEE INSIDE FRONT COVER FOR DETAILS OF YOUR LOCAL SALES OFFICE Tel: Fax:

2 5.8 A IR PREPARATION R EGULATOR SERIES AR Port Size M5 Rc Q and P compensation Design includes panel mount ring High flow Non-modular, higher flow and precision type regulators are available (see index) Check valve option available uilt in gauge available Model AR000 AR2000 AR2500 AR000 AR4000 AR5000 AR6000 Port size M5x Flow rate ln/min* Max. supply pressure ar 5 Max. operating pressure ar 0 Pressure regulating range ar ~ 8.5 (AR*000) (ar*060) Optional low pressure regulator range ar 0.2~2 Port size for pressure gauge Ambient and media temperature 5 ~ 60 C Construction Relieving type * 7 bar supply, pressure = 5 bar, Pressure drop P = bar PRESSURE REGULATOR AR 0 M Relieving 6 With check valve * uilt-in gauge not available with this option. Standard on AR000 GAUGE 0 With gauge port With built in gauge (Available for body sizes 20~40 only) M5 M5 PRESSURE REGULATOR S Y M O L S AR AR2000/ AR AR AR AR6000 P RESSURE GAUGES See Pressure Gauges Page Relieving type Check valve type Nil For AR**00 type G Gauge for AR**0 type REGULATOR RANGE Nil Standard Low pressure 0.2~2 ar R For right to left flow (with built in gauge type only)

3 A IR PREPARATION 5.9 AR000~AR5000 AR6000 Model A C D E F G H J K L M N AR AR AR AR AR AR AR AR200 ~ AR400 Port Size Model Part Size A C D E Dimensions N F G H J K L M AR200 /8 / AR25O /4 / AR00 /4 / AR400 /4 /8 / ORDER LINES Castle Hill NSW...Tel: (02) Fax: (02) SEE INSIDE FRONT COVER FOR DETAILS OF YOUR LOCAL SALES OFFICE Tel: Fax:

4 5.0 A IR PREPARATION L URICATOR SERIES AL Port Size M5 Rc Precise adjustment Uniform lubrication even at extremely low flow rates Over 97% of atomised oil particles <0 microns Quick release bowl guard on some sizes S Y M O L S Model AL000 AL2000 AL000 AL4000 AL5000 AL6000 Port size M5x Flow Rate ln/min Max. supply pressure ar 5 Max. operating pressure ar 9.9 Min. operating flow ln/min* 4 5 4: 0 8: 40 8: 40 2: owl capacity cm Recommended oil ISO VG2 Ambient and media temperature 5 ~ 60 owl material Accessory (standard) owl guard - - *Conditions: Supply pressure - 5ar Number of DROPS - 5 drops/min. ISOVG2, 20 C Max. flow 5 bar supply 0. bar pressure drop LURICATOR 000 M AL M5 M AL000 AL2000 AL000 AL4000 AL5000 AL6000 Model A C D F G H J K L M P AL AL AL AL AL AL LURICATOR 240 AL AL AL AL5000/6000

5 A IR PREPARATION 5. F ILTER REGULATOR SERIES AW Port Size M5 4 Rc Differential or float type autodrain Quick release bowl guard on some sizes High flow 5µm filter element uilt in gauge available Model AW000 AW2000 AW200 AW000 AW00 AW4000 AW400 Port size M5x Flow rate ln/min* Max. supply pressure ar 5 5 Max. operating pressure ar 0 0 Pressure regulating range ar 0.5 ~ ~ ~ 8.5 Port size for pressure gauge 6 Ambient and media temperature Filtration 8 N/A 8 5 ~ 60 C Standard: 5µm N/A 4 N/A 5 ~ 60 C Standard: 5µm owl capacity cm owl material Construction/regulator Relieving type Relieving type Accessory(standard) owl guard *7 bar supply, 5 bar static set pressure, bar pressure drop S Y M O L S FILTER REGULATOR 0 M AW 0 0 Standard With built in gauge 2 With built in gauge for right to left flow ( & 2 available for body sizes 20~40 only) M5 M AUTODRAIN Nil Without D With Nil For AW**0 type G Gauge for AW**00 type ORDER LINES Castle Hill NSW...Tel: (02) Fax: (02) SEE INSIDE FRONT COVER FOR DETAILS OF YOUR LOCAL SALES OFFICE Tel: Fax: FILTER REGULATOR Filter Element 5µm 4-5 AW AW AW AW AW AW AW AW AW AW4000 SEE NEXT PAGE

6 5.2 A IR PREPARATION AW AW ANW000: Max..5t AW2000: Max. 5t AW200: Max..5t AW000: Max..5t AW4000: Max. 5t AW400: Max..5t AW400:Max. 5t MODEL A C D E F G H J K L M ØN P AW Differential pressure AW Differential pressure AW Float AW Float AW200 AW L G K E D F M C J S H Port Size Pressure Gauge Port Size Pressure Gauge P Drain A (differential pressure type) Drain Minimum space required for maintenance Minimum space required for maintenance MODEL A C D E F G H J K L M ØN P AW Differential pressure AW Float AW Float

7 A IR PREPARATION 5. Model AFM2000 AFM000 AFM4000 Port size bar supply, 0. bar pressure drop (new) Flow rate ln/min* Max. supply pressure ar 5 Max. operating pressure ar 0 Min. operating pressure ar 0.5 owl material Accessory (standard) owl guard - M IST SEPARATOR SERIES AFM Port Size 8 4 Rc Removes more than 99.9% of oil mist 0.µm filter element Quick release metal bowl guard on some sizes Automatic or manual drain Mist Separators are also available in larger port sizes - see: Filters: High Efficiency MIST SEPERATOR AFM2000 S Y M O L S MIST SEPARATOR AFM AUTODRAIN Nil Without D With MIST SEPERATOR AFM MIST SEPARATOR Filter Element 606 AFM AFM AFM4000 Filter Elements should be changed after year or when a pressure drop of ar is reached. 240 AFM AFM AFM4000 Model Port size A C D E F G H J K L M P AFM2000 /8 / Differential pressure AFM000 /4 / Differential pressure AFM4000 /4 /8 / Float type AFM / Float type ORDER LINES Castle Hill NSW...Tel: (02) Fax: (02) SEE INSIDE FRONT COVER FOR DETAILS OF YOUR LOCAL SALES OFFICE Tel: Fax:

8 5.4 A IR PREPARATION M ICRO-MIST SEPARATOR SERIES AFD Port Size 8 4 Rc Removes more than % of oil mist 0.0µm filter element Quick release metal bowl guard on some sizes Automatic or manual drain Micro-Mist Separators are also available in larger port sizes - see: Filters: High Efficiency MIST SEPERATOR AFD2000 Model AFD2000 AFD000 AFD4000 Port size Flow rate ln/min* Max. supply pressure ar 5 Max. operating pressure ar 0 Min. operating pressure ar 0.5 owl material Accessory (standard) owl guard 7 bar supply, 0. bar pressure drop (new) - MIST SEPERATOR AFD AUTODRAIN Nil Without D With M5 M MIST SEPERATOR AFD S Y M O L S MIST SEPERATOR Filter Element 6092 AFD AFD AFD4000 Filter Elements should be changed after year or when a pressure drop of ar is reached. 240 AFD AFD AFD AFD Model Port size A C D E F G H J K L M P AFD2000 /8 / Differential pressure AFD000 /4 / Differential pressure AFD4000 /4 /8 / Float type AFD / Float type

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

Micro oil-mist lubricator, Series NL2-LBM G 1/4

Micro oil-mist lubricator, Series NL2-LBM G 1/4 Version Micro oil-mist lubricator, an be assembled into blocks Mounting orientation vertical Working pressure min./max. 0.5 bar / 6 bar Medium ompressed air Neutral gases Medium temperature min./max. -0

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8" to 1-1/2" port sizes

Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8 to 1-1/2 port sizes Section 12 Filter/Regulators Compressed air, general purpose, and Instrument Filter/Regulators 1/8" to 1-1/2" port sizes B7 Miniature eneral Purpose Filter/Regulator 1/8" and 1/" ports...................................le-12-2

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake

More information

FILTER TECHNICAL DATA COMPONENTS

FILTER TECHNICAL DATA COMPONENTS TR The Job of the filter is to remove any solid or liquid impurities from the air generated by the compressor. ncoming air is rotated by the centrifuge unit. The heaviest liquid and solid particles are

More information

MANTA Piston Distributor for Oil and Fluid Grease

MANTA Piston Distributor for Oil and Fluid Grease MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube

More information

Membrane air dryers MS-LDM1, MS series

Membrane air dryers MS-LDM1, MS series Membrane air dryers MS-LDM1, MS series Membrane air dryers MS-LDM1, MS series Product range overview MS series service units Type Size Pressure regulation range [bar] Grade of filtration [μm] Pneumatic

More information

Valve systems Base plates, according to standard ISO 5599-1. Brochure

Valve systems Base plates, according to standard ISO 5599-1. Brochure ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

Return line filters. Return line filters

Return line filters. Return line filters Return line filters Return line filters Index Technical data - 5 Filters series 6 Filters series --3 8 ccessories Spare parts Uni-ardan Italia S.p.. reserves the right to make technical changes to the

More information

ETC -SV. Class 0 oil-free compressed air through catalysis

ETC -SV. Class 0 oil-free compressed air through catalysis Innovation QUALITy Reliability Worldwide ETC -SV Class 0 oil-free compressed air through catalysis The way to oil-free compressed air The ETC operating principle Through the process of catalytic oxidation,

More information

Service units MSB-FRC, MS series

Service units MSB-FRC, MS series Service units MSB-FRC, MS series Service units MSB-FRC, MS series Product range overview MS series service units Type Size Pressure regulation range [bar] Grade of filtration [µm] Pneumatic connection

More information

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these

More information

In-Line Filters and Coalescers with Automatic Drains

In-Line Filters and Coalescers with Automatic Drains Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid

More information

WASTE OIL DRAINERS 99. Waste oil drainers

WASTE OIL DRAINERS 99. Waste oil drainers WASTE OIL DRAINERS 99 8 100 WASTE OIL DRAINERS wheel-mounted for drums 20/220 kg Art. 42050 (20/60 kg) Art. 42000 (180/220 kg) Art. 42050 Waste oil drainer for tanks or drums composed of: art. 80050 Trolley

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

Aerospace and Defence

Aerospace and Defence Aerospace and Defence Hydraulic, Fuel, Lubrication and Air Systems World Class Filtration Solutions Porvair Filtration Group Aerospace and Defence Hydraulic, Fuel, Lubrication and Air Systems Porvair Filtration

More information

How To Order A Direct Flow Air Cleaner

How To Order A Direct Flow Air Cleaner Reduced Volume - Improved Performance - Flexible Packaging The patented Direct Flow technology provides the flexibility to optimize the air system performance to size ratio, meeting the demands of today

More information

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9 Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Cylinders DIN ISO 6431 and VDMA 24 562

Cylinders DIN ISO 6431 and VDMA 24 562 Double acting Standard executions Version Shape of barrel Symbol Type MAGNETIC STANDARD AMA AMT 1 For the magnetic reed switches type ASV see from page 1.110.1. For coupling cylinders/reed swiches/brackets

More information

Battery Powered Digital Mass Flow Meters for Gases

Battery Powered Digital Mass Flow Meters for Gases Next Generation red-y compact: AA Battery Powered Touch Technology Micro-UB Port red-y compact series product information Battery Powered Digital Mass Flow Meters for Gases Independent digital convenience:

More information

Filter Elements E 7.200.9/05.06

Filter Elements E 7.200.9/05.06 HYDAC Filter Elements safeguard the performance and service life of essential and expensive hydraulic components due to their high standard of quality Filter Elements Technical details: Absolute filtration

More information

Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information: Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Battery Powered Thermal Mass Flow Meters for Gases

Battery Powered Thermal Mass Flow Meters for Gases red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

Pressure reducing valve, direct operated, Type ZDR 6 D

Pressure reducing valve, direct operated, Type ZDR 6 D RE 26 57/2.3 Replaces:.2 Pressure reducing valve, direct operated, ype ZDR 6 D Nominal size 6 Series 4X aximum operating pressure 2 bar aximum flow 5 L/min K 4279/ ype ZDR 6 DP2 4X/ Y Overview of contents

More information

Battery Powered Thermal Mass Flow Meters for Gases

Battery Powered Thermal Mass Flow Meters for Gases red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases Digital advantage: Thermal Mass Flow Meters for Gases The flow meters red-y compact series are characterized

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

Ultra-Filter. Compressed Air Filter. DF Series

Ultra-Filter. Compressed Air Filter. DF Series Ultra-Filter DF Series ié~çáåö=íüé=t~ó=áå=^áê=mìêáñáå~íáçå As one of the world s leading manufacturers of compressed air purification equipment, Donaldson has built a comprehensive engineering, manufacturing,

More information

Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation

Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation Industrial Filters Accumulators Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400 Filters for inline installation for continuous operation With integrated pressure equalisation valve Optimised flow

More information

DATA PD-111-400. RE21.., KX..., 1194339 Quick Release Valves. Product. Function. Technical Features. Range Overview

DATA PD-111-400. RE21.., KX..., 1194339 Quick Release Valves. Product. Function. Technical Features. Range Overview Commercial Vehicle Systems Product DATA Function RE.., KX..., 949 Doc. No. Y058 (Rev. 00) February 0 PD--0 The Quick Release Valve is generally used in the supply to the spring portions of spring brake

More information

15/40/80CN Series Medium Pressure Filters

15/40/80CN Series Medium Pressure Filters 1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)

More information

Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information: Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure

More information

2-way flow control valve Type 2FRM 6

2-way flow control valve Type 2FRM 6 RE /0.0 Replaces:.0 -way flow control valve Type FRM Nominal size Series X Maximum operating pressure bar ) Maximum flow L/min ) When used in conjunction with a rectifier plate up to 0 bar H//D /97 + H//D

More information

Hydraulic multidisc Brake H420

Hydraulic multidisc Brake H420 S320gb - rev 02/09 S E R V I C E Hydraulic multidisc Brake H420 A N U A L WARNER ELECTRIC EUROPE Rue Champfleur, B.P. 20095, F- 49182 St Barthélemy d Anjou Cedex Tél. +33 (0)2 41 21 24 24, Fax + 33 (0)2

More information

Lava. Precision Solutions. Site Planning and Installation Guide

Lava. Precision Solutions. Site Planning and Installation Guide Lava Precision Solutions Site Planning and Installation Guide TABLE OF CONTENTS Table of Contents Introduction...........................................................................................

More information

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting Adding Pneumatic Preset Counter Type 497 Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting VARIABLE PILOT SIGNAL Using two pneumatic preset counters

More information

Radial piston pumps type R and RG

Radial piston pumps type R and RG Radial piston pumps type R and RG Operating pressure p max = 700 bar Delivery flow Q max = 91.2 lpm (at 1450 rpm) Geometric displacement V g max = 64.2 cm 3 /rev. 1. General Motor pumps and hydraulic power

More information

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications VARIABLE DISPLACEMENT AXIAL PISTON PUMPS For truck applications TVP FEATURES Variable displacement axial piston pumps swash plate design ideally suited for open circuit truck applications. The compact

More information

15/40/80CN Series Coreless Medium Pressure Filters

15/40/80CN Series Coreless Medium Pressure Filters //8CN Series Coreless Medium Pressure Filters //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment Pilot

More information

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30 85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08

More information

HFS and HFD Series. High Flow Single and Duplex Filters Max. 11200 l/min. 10 bar. Heavy Duty Reliability. Applications: Contact Information:

HFS and HFD Series. High Flow Single and Duplex Filters Max. 11200 l/min. 10 bar. Heavy Duty Reliability. Applications: Contact Information: High Flow Single and Duplex Filters Max. 11200 l/min. 10 bar Heavy Duty Reliability New High Flow Single and Duplex Filters ensure reliability in industrial, marine, and power generation applications up

More information

size 3 15 4200 size 4 19 6600

size 3 15 4200 size 4 19 6600 BE/BE ISO 99/ Valves - Compliance with ISO 99/ international standards - Full range: - - - size - Two different internal commutation system: mixed and spool, appreciated for decades thanks to their maximum

More information

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas SFS81 Series Servo Finishing Stand PUSHCORP, INC. Dallas, Texas May, 2012 NEVER OPERATE THE SFS81 MANUALLY NEVER OPERATE THE SFS81 WITH PERSONEL IN THE WORKCELL DO NOT USE LUBRICATED AIR. This device requires

More information

Norgren Air Preparation Products and Accessories

Norgren Air Preparation Products and Accessories APC-14 Contents 21 Norgren Air Preparation Products and Accessories Compressed Air Systems............................. ALE--2 Filters............................................ ALE-1-A Oil Removal (Coalescing)

More information

PUMP AND MOTOR DIVISION

PUMP AND MOTOR DIVISION INSTALLATION MANUAL SERIES P2 and P3 MOBILE PISTON PUMP 1 Check model code / compare with your paper work Nameplate of the pump Ordering / Sales Acknowledgement 2 Check rotation of the pump Clockwise rotation

More information

Filters General Purpose Filters, Oil Removal (Coalescing) Filters, Oil Vapor Removal (Adsorbing) Filters, and Compressed Air Membrane Dryers

Filters General Purpose Filters, Oil Removal (Coalescing) Filters, Oil Vapor Removal (Adsorbing) Filters, and Compressed Air Membrane Dryers Filter Contents Filters General Purpose Filters, Oil Removal (Coalescing) Filters, Oil Vapor Removal (dsorbing) Filters, and Compressed ir Membrane Dryers Filter Overview..............................LE-Filter

More information

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711 A10VO Nominal size 18 see RD 92712 A10VO Nominal size 28...140 see RD 92711 The variable displacement axial piston pump A10VO in swashplate design was designed for hydrostatic drives in open circuits.

More information

Control blocks for two-hand start ZSB

Control blocks for two-hand start ZSB Key features Function This pneumatic control block for twohand start ZSB is used where a manually started operation, such as the triggering of compressed air cylinders, would otherwise involve danger for

More information

Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min Steering unit RE 11872/05.06 /10 Type LAGL Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min H7375 Table of contents Contents Page Features 1 Ordering code 2 Function, section 3 Device

More information

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF Tandem 900 Off-line filter Systems can be applied to every imaginable industrial application where hydraulic or lubrication systems are present. An integrated

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide Brochure 99795, updated August 2002 1. Introduction Stanadyne has been making diesel fuel filters for over 30 years. Stanadyne

More information

Cylinders Series 40. Double acting, cushioned, magnetic ø160-200 - 250 (DIN/ISO 6431)

Cylinders Series 40. Double acting, cushioned, magnetic ø160-200 - 250 (DIN/ISO 6431) Cylinders Series 40 Double acting, cushioned, magnetic ø60-200 - 250 (DIN/ISO 643)»»» DIN/ISO 643 VDMA 24562 Rolled stainless steel rod Adjustable cushioning The cylinders Series 40 with diameters 60,

More information

Operating instructions Mechatronic flow sensor. SBY33x 704465/06 03/2011

Operating instructions Mechatronic flow sensor. SBY33x 704465/06 03/2011 Operating instructions Mechatronic flow sensor SBY33x 7065/06 03/2011 Contents 1 Safety instructions...2 2 Functions and features...3 3 Installation...3 Electrical connection... 5 Switch point setting...

More information

Compressed air conditioning

Compressed air conditioning Compressed air conditioning The basis for outstanding compressed air quality Efficient compressed air systems & services for small and medium companies Application recommendation The compressed air cold

More information

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999 CONTAMINATION CONTROL in hydraulic systems in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further information.

More information

Backflush filter R8-30W

Backflush filter R8-30W Backflush filter R8-30W With internal pressure segment cleaning, rated pressure to 40 bar (580 psi) Connection sizes: DN 200 to DN 500, welded design 1. Features Powerful, fully automatic filtration _

More information

Self Purging Liquid Trap (SPLT ) User s Manual

Self Purging Liquid Trap (SPLT ) User s Manual Self Purging Liquid Trap (SPLT ) User s Manual High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High

More information

BGAH Series. Medium Pressure Filters Max. 500 l/min. 25 bar. In-line solution for a straight pipeline. Applications: Contact Information:

BGAH Series. Medium Pressure Filters Max. 500 l/min. 25 bar. In-line solution for a straight pipeline. Applications: Contact Information: BGAH Series Medium Pressure Filters Max. 500 l/min. 25 bar In-line solution for a straight pipeline Pre-filtration by magnet column and a full-flow bypass with low hysteresis. Contamination-proof in-out

More information

DIESEL FUEL CONDITIONING

DIESEL FUEL CONDITIONING COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17) 17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure

More information

Stainless Steel Cylinders DIN ISO 6431 and VDMA 24 562

Stainless Steel Cylinders DIN ISO 6431 and VDMA 24 562 Bores from 32 to 200 mm Double acting Standard executions Version Symbol TYPE MAGNETIC STANDARD AMX STAINLESS STEEL For the magnetic reed switches type ASV see from page 1.110.1. For coupling cylinders/reed

More information

Extruded Body Cylinders, ISO 6431, ISO 15552 compliant Series 62

Extruded Body Cylinders, ISO 6431, ISO 15552 compliant Series 62 1 ISO / VDMA Cylinders NORTH AMERICAN CYLINDER & ACTUATOR CATALOG > Release 8.5 Extruded Body Cylinders, ISO 6431, ISO 15552 compliant Series 62 Double-acting, magnetic, cushioned ø 32, 40, 50, 63, 80,

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators Condensate Treatment Solutions CTS Series Eliminator II Oil-Water Separators 2 Condensate Treatment Solutions A Cleaner Environment & Reduced Disposal Costs Compressed air is compressed and discharged

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference

More information

Series TMM Axial Piston Motor. Technical Information

Series TMM Axial Piston Motor. Technical Information Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer

More information

Marine Generating Sets 3.7 to 50 kva

Marine Generating Sets 3.7 to 50 kva Marine Generating Sets 3.7 to 50 kva The Marine Engineer s Preference BetaSet - Standard Marine Generators Beta Marine has considerable experience from over twenty years of manufacturing marine generating

More information

Compact Air Solutions C Series 2.2 7.5 kw Screw Compressors Want a 5. year warranty? Ask for details!

Compact Air Solutions C Series 2.2 7.5 kw Screw Compressors Want a 5. year warranty? Ask for details! Compact Air Solutions C Series 2.2 7.5 kw Screw Compressors Want a 5. year warranty? Ask for details! Air. CompressedAir. BogeAir. Now you can! CM compact module 2.2 7.5 kw Effective free air delivery:

More information

Axial Piston Variable Pump KVA

Axial Piston Variable Pump KVA Electric Drives and Controls Hydraulics Linear Motion and Assembly echnologies Pneumatics ervice Axial Piston Variable Pump KVA E 92250/02.07 /16 eplaces: 04.06 echnical data sheet eries 6 izes 55... 107

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

Variable Displacement Pump AA10VSO

Variable Displacement Pump AA10VSO Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi

More information

Basic Hydraulics and Pneumatics

Basic Hydraulics and Pneumatics Basic Hydraulics and Pneumatics Module 1: Introduction to Pneumatics PREPARED BY IAT Curriculum Unit March 2011 Institute of Applied Technology, 2011 ATM 1122 Basic Hydraulics and Pneumatics Module 1:

More information

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS 4 AMIAD PLASTIC FILTERS, SCREENS & DISCS Max pressure 10.0 Bar, max temperature 60 O 3/4 to 1 1/2 bodies manufactured from polyacetal 2 bodies and above manufactured from polymade and glass fibre 3/4 to

More information

Series IDU/IDF. Refrigerated Air Dryer

Series IDU/IDF. Refrigerated Air Dryer Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In

More information

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + removal Diesel PreCare: The Clear Link Guaranteed HYDAC quality thanks to HYDAC Quality

More information

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS Oil Free Scroll Compressors are constantly evolving ANEST IWATA was the first manufacturer to introduce Oil Free Scroll Compressors in 1991 and has kept

More information

DATA PD-500-000. SV13.., SV14.. Levelling Valves. Product. Function. Technical Features. Range Overview

DATA PD-500-000. SV13.., SV14.. Levelling Valves. Product. Function. Technical Features. Range Overview Commercial Vehicle Systems Product DATA SV.., SV.. Doc. No. Y075 (Rev. 00) PD-500-000 Function On vehicles fitted with air suspension, the Levelling Valve ensures that the axle suspension air bags maintain

More information

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement Program Summary Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement 2 Table of content Content Fluid & Motion Control 3 Directional Control Valves, solenoid operated 4 Directional

More information

MovinCool Office Pro Series. The Portable Spot Cooling Solution

MovinCool Office Pro Series. The Portable Spot Cooling Solution MovinCool Office Pro Series The Portable Spot Cooling Solution The Office Pro 2002 American Standard Inc. All rights reserved Losing Is Not An Option With The Office Pro Series. The loss of data and equipment

More information

MHT. Pressure Filters HIGH PRESSURE INLINE FILTER

MHT. Pressure Filters HIGH PRESSURE INLINE FILTER MHT Pressure Filters HIGH PEUE INLINE FILTE Pressure Filters MHT MHT 4 MPa ( bar) Port sizes: / / Flow rates: 0 l/min TEHNIAL DATA Max. working pressure: 4 MPa ( bar) Max. testing pressure: 6 MPa (60 bar)

More information

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed or totally immersed into a

More information