2 - Motor starters - enclosed version

Size: px
Start display at page:

Download "2 - Motor starters - enclosed version"

Transcription

1 Contents - Motor starters - enclosed version Selection guide page / VARIO enclosed switch disconnectors # Pre-assembled page / # Assembled by user page /5 # Add-on modules page /6 Enclosed thermal-magnetic motor circuit-breakers # Type GV-ME 5 Standard page /10 5 Assembly of a safety enclosure for safety applications page /1 # Type GV-M page /11 D.O.L. starters for motor control # 0.55 to 0 kw 5 With manual control and with magnetic circuit breaker, page /1 #. to 5 kw 5 Without isolating device page /16 5 With isolating device page /0 # 0.5 to 7.5 kw 5 With -phase thermal overload relay page / # 0.7 to 5.5 kw 5 With thermal magnetic circuit-breaker and contactor page /6 Star-delta starters for motor control # 5.5 to 1 kw 5 Without isolating device page /8 # 7.5 to 75 kw 5 With isolating device page / # 90 to 75 kw 5 Without isolator page /8 # For use on a machine subject to the application of machinery directive 98/7/CE Non reversing page /6 5 Reversing page /6 5 Non reversing with integral transformer page /68 5 Reversing with integral transformer page /69 D.O.L. starters for control in category AC-1 # Without isolator page /0 # With off-load isolator page / /0

2 integral 18, and 6 contactor breakers and reversing contactor breakers # Enclosures and door interlock mechanisms for customer assembly... page /8 integral and 6 contactor breakers and reversing contactor breakers # Enclosures page /5 # Door interlock mechanisms page /55 # For the control and protection of motors page /56 # For control and protection of resistive circuits in category AC page /58 # Auxiliary contact blocks and accessories page /59 Enclosed D.O.L. starters for AS-i bus # Models LF 1-M, LF-M, LF1-P or LF -P page /7 # Model LF7-P page /7 # Model LF8-P page /75 # Accessories page /77 Interface modules LA9-Z # For D.O.L. starters for AS-i bus page /91 /1

3 General selection guide TeSys enclosed starters Applications D.O.L. starters Type Standard starters Starters for safety applications Standard power ratings 7 kw kw kw kw kw. 5 kw kw of -phase motors in AC- 00/15 V Starters Manual p p p p Auto p p p Isolation Switch p Circuit-breaker p p p p Disconnector p Protection Short-circuit p p p p p Overload p p p p p p Communication References VpF GV-ME GV-LC LE1-GVME LE1-M LE-K GV-ME Non reversing VCFN GV-CE GV-NGC LE1-D LE-D VpFX Reversing LE-K LE8-K LE8-D LE-D LE-D Pages 008/ and 008/ 806/ and 806/ (1) Please consult your Regional Sales Office. 110/ 111/ 101/, 101/ and 105/ 10/ and 10/ 1058/ and 1058/ 0Q-EN_Ver..fm/

4 Soft start units Variable speed controllers AS-i bus Standard Electronic starters star-delta soft start - starters soft stop units kw kw kw kw 0.7 kw kw 1 kw 75 kw p (LH7-0M) p p p p p p p p (LH7-KP) p p p p p (from 7.5 kw) p p p p p (up to 5.5 kw) p p p p p p p p p p p p p p p p p p LG1-K LG7-K LF1-M LE-K LE6-D LH7-0 ATV-8E ATV-58E LG1-D LG7-D LF1-P LE-D LE-D LH7-K LJ7-K LF7-P LE-F (1) LG8-K LF-M ATV-8E ATV-58E LJ8-K LF-P LF8-P 06/ 06/ and 06/, 60/ and 60/ 08/ to 088/ 106/ and 106/ 108/ and 108/ 07/ and 07/ (1) 0Q-EN_Ver..fm/

5 References Enclosed starters VARIO enclosed switch disconnectors, pre-assembled Enclosed switch disconnectors for high performance applications - -pole switch disconnectors, 10 to 10 A, rotary operator, conforming to IEC and IEC 0. - Padlockable handle (padlocks not included). - IP 65 degree of protection enclosure, lead sealable and lockable. - Lockable cover in position I (ON) up to 6 A rating. - Marking on front plate VCF-0GE -pole main and emergency stop switch disconnectors (1) Operator Ithe Power Incorp- Possible Reference Weight Handle Front plate AC- orated attach- Dimensions at 00 V switch ments body () mm A kw kg Red Yellow 10 V0 VCF-0GE Padlockable, 60 x 60 up to locks V01 VCF-01GE (Ø to 8 shank) V0 VCF-0GE V1 VCF-1GE V VCF-GE V VCF-GE V VCF-GE 0.90 VCF-GE Red cross Yellow V5 1 VCF-5GE.190 type 90 x 90 Padlockable, up to locks 10 5 V6 1 VCF-6GE.190 (Ø to 8 shank) -pole main stop switch disconnectors (1) Black Black 10 V0 VBF-0GE Padlockable, 60 x 60 up to locks V01 VBF-01GE (Ø to 8 shank) V0 VBF-0GE V1 VBF-1GE V VBF-GE V VBF-GE V VBF-GE 0.90 VBF-0GE Black cross Black V5 VBF-5GE.190 type 90 x 90 Padlockable, up to locks 10 5 V6 VBF-6GE.190 (Ø to 8 shank) Enclosed switch disconnectors for standard applications - -pole switch disconnectors, 10 to A, rotary operator, conforming to IEC Degree of protection IP 55. -pole main and emergency stop switch disconnectors (1) Red Yellow 10 VN-1 VCFN-1GE () 0. Padlockable, 60 x 60 either by 1 lock VN-0 VCFN-0GE () 0. (Ø 8 shank) or by locks V0 0 VCFN-5GE 0.51 (Ø 6 shank) 5 11 V1 0 VCFN-GE 0.51 VCFN-1GE Dimensions : page 010/ 008_Ver.10-EN.fm/ 15 V 0 VCFN-0GE 0.51 (1) For characteristics of switch disconnectors, please consult your Regional Sales Office. () For VCF and VBF enclosures, see page 009/. For VCFN enclosures, see page 009/. Schemes : page 010/

6 References Enclosed starters VARIO enclosed switch disconnectors, assembled by user Empty enclosures IP 65 enclosure with red padlockable handle operator and yellow front plate (for mounting a main or emergency stop switch disconnector) For switch Ithe Possible Reference Weight body attachments (1) A kg VN-1, VN-0 10 VCFX-GE1 0.0 V0 V V0 V 10 VCFX-GE VBFX-GE V and V 50 6 VCFX-GE VCFX-GDXE IP 65 enclosure with black padlockable handle and black front plate (for mounting main stop switch disconnector) For switch Ithe Possible Reference Weight body attachments (1) A kg VN-1, VN-0 10 VBFX-GE1 0.0 V0 V V0 V 10 VBFX-GE V and V 50 6 VBFX-GE VBFX-GDXE Switch bodies for standard applications () Description Rating Reference Weight A kg -pole switch disconnectors 10 VN VN Switch bodies for high performance applications () Description Rating Reference Weight A kg -pole switch disconnectors 10 V V V V0 5 V V V V 0.00 (1) See pages 009/ and 009/. () For characteristics of switch disconnectors, please consult your Regional Sales Office. Dimensions : pages 010/ and 010/ Schemes : page 010/ 008_Ver.10-EN.fm/

7 References Enclosed starters VARIO enclosed switch disconnectors Add-on modules Add-on modules for enclosures VCF and VBF Description Rating Reference Weight A kg Main pole module 10 VZ (mounted in enclosure) 16 VZ VZ VZ-0 VZ-11 5 VZ VZ VZ VZ Neutral pole modules 10 to VZ with early make and late break contacts 50 and 6 VZ and 10 VZ Earthing modules 10 to VZ and 6 VZ and 10 VZ VZ-15 VZ-0 Auxiliary contact block modules N/O + N/C (1) VZ with auxiliary contacts N/O + N/O VZ Maximum number of add-on modules which can be fitted on a switch body 1 add-on module on each side of the switch body. VZ-7 or VZ-0 + V0/ + VZ-7 or VZ-0 or VZ-11 or VZ-1 + or V0 or + VZ-11 or VZ-1 or VZ-1 or VZ-15 + to + VZ-1 or VZ-15 or V VZ-0//VZ-0 to VZ- + + VZ-0//VZ-0 to VZ- or add-on modules on each side of the switch body. VZ-0/ + VZ-0/ + V0/ + VZ-0/ + VZ-7 or VZ-0 or VZ-11 or VZ-1 VZ-0 + VZ-0 + V0 + VZ-0 + VZ-7 or VZ-0 or VZ-11 or VZ-1 VZ-1 + VZ-1 + V1 + VZ-1 + VZ-7 or VZ-0 or VZ-11 or VZ-1 VZ- + VZ- + V + VZ- + VZ-7 or VZ-0 or VZ-11 or VZ-1 VZ- + VZ- + V + VZ- + VZ-7 or VZ-0 or VZ-1 or VZ-15 VZ- + VZ- + V + VZ- + VZ-7 or VZ-0 or VZ-1 or VZ-15 Note: The add-on modules mounted next to the switch body are main poles. Maximum of main poles per switch body. (1) Late make N/O contact, early break N/C contact Schemes : page 010/ 009_Ver.10-EN.fm/

8 References Enclosed starters VARIO enclosed switch disconnectors Add-on modules Add-on modules for enclosures VCFN-1GE and 0GE Description Rating Reference Weight A kg Main pole module 10 VZN VZN VZN Neutral pole module with early 10 and 16 VZN make and late break contacts Earthing module 10 and 16 VZN VZN-1 Auxiliary contact block module 1 late make N/O contact VZN early break N/C contact VZN VZN-05 Maximum number of add-on modules which can be fitted on switch body VZN-1 or VZN VZN-1 or VZN-0 VN-1 or or VZN-11 or VN-0 or VZN-05 or VZN-06 or VZN-05 or VZN-06 VZN-1 Schemes : page 010/ 009_Ver.10-EN.fm/

9 Dimensions Enclosed starters VARIO enclosed switch disconnectors VCFN-1GE to VCFN-0GE = = ,5 Cable glands: x 16 P top and bottom VCF or VBF-0GE to GE VCFX or VBFX-GE1 to GE H b c1 c = = a a b c c1 H V/F-0GE to V/F-GE, V/FX-GE1 (1) V/F-GE and V/F-GE () V/FX-GE and V/FX-GE () (1) Cable glands x 16 P top and bottom () Cable glands x 16/1/9 P top and bottom VCF or VBF-5GE and 6GE = 01 = References : page 008/ Schemes : page 010/ 010_Ver.10-EN.fm/

10 Dimensions Enclosed starters VARIO enclosed switch disconnectors, for customer assembly Empty enclosures VCFX or VBFX-GDXE /T1 /T 6/T 1/L1 /L 5/L = 180 = 0 Schemes Switch disconnectors Main pole Neutral pole enclosed module module or switch bodies Auxiliary contact blocks VZ-7 VZ-0 VZN-05 VZN-06 References : page 008/ 010_Ver.10-EN.fm/

11 References TeSys enclosed starters Enclosed thermal-magnetic motor circuit-breakers type GV-ME and accessories, forcustomerassembly Thermal-magnetic motor circuit-breakers GV-ME 50077_1 Motor circuit-breakers and accessories : see pages 508/, 51/ and 51/9. Starters consisting of an enclosed motor circuit-breaker GV-ME conform to IEC GV- ME01 ME0 ME0 ME0 ME05 ME06 ME07 ME08 ME10 ME1 ME16 ME0 ME1 ME Ithe enclosed (A) Enclosures for thermal-magnetic motor circuit-breakers GV-ME GV-MC Type Degree of protection Max. no. of side mounted Reference Weight contacts on GV-ME LH RH kg 50080_1 Surface IP GV-MC mounting, double insulated with protective IP GV-MC conductor. or GV-MCK0 (1) 0.0 Sealable cover IP 55 for 1 1 GV-MC temperature < + 5 C GV-MP Flush IP 1 (front face) 1 1 GV-MP mounting with protective conductor IP 1 (reduced 1 GV-MP flush mounting) IP 55 (front face) 1 1 GV-MP Front plate IP 55 (reduced 1 GV-MP flush mounting) 50078_1 For direct control, through a panel, IP 55 GV-CP of a chassis mounted GV-ME Accessories common to all enclosures (to be ordered separately) GV-CP Description Sold in Unit Weight lots of reference kg Padlocking kit () 1 to padlocks 1 GV-V for GV-ME operator (padlocking is Ø to 8 mm only possible in the O position) 50079_1 Mushroom Spring return () 1 GV-K head Stop pushbutton Latching () Key release 1 GV-K Ø0mm, IP 55 (key n 55) red Turn to 1 GV-K release 1 GV-K0 () 0.10 GV-K011 Sealing For enclosures IP GV-E kit and front plates IP GV-E for θ <+5 C Neutral link 100 AB1-VV65UBL Cover 50 AB1-AC6BL 0.00 (1) Enclosure GV-MCK0 has a mushroom head Stop pushbutton GV-K0 fitted as standard. () Supplied with IP 55 sealing kit. To be fitted with GV-Mp01. () Padlocking in the O position by padlock with Ø to 8 mm shank. 70-EN_Ver1.0.fm/

12 References TeSys enclosed starters Enclosed thermal-magnetic motor circuit-breakers type GV-M and accessories, for customer assembly Thermal-magnetic motor circuit-breakers GV-ME 8118 Motor circuit-breakers and accessories : see pages 508/5 and 51/5. GV-ME0 : operational current in enclosure limited to 0 A. Starters consisting of an enclosed GV-ME conform to IEC Metal enclosure for thermal-magnetic circuit-breakers GV-ME Application Type Degree of protection Reference Weight of enclosure kg GV-CE01 Motor Surface mounting IP 55 GV-CE circuit-breaker up to 0 A with or without accessories Enclosure accessories (to be ordered separately) 8119 Description Sold in Unit Weight lots of reference kg Sealing For θ 5 C 10 GV1-EA membrane (1) For θ < 5 C (silicone) 10 GV1-EA GV1-V IP 55 padlocking device for operators (when padlocked, the motor circuit is automatically in the Open (OFF) position) 1 GV1-V Stop pushbutton Spring return 1 GV1-K Ø0 mm,red mushroom head (supplied with IP 55 sealing kit) GV1-K01 Latching Key release 1 GV1-K (key n 55) Turn 1 GV1-K to release (1) Spare part. 70-EN_Ver1.0.fm/

13 References TeSys enclosed starters 0 Enclosed thermal-magnetic motor circuit-breakers type GV ME and accessories Assembly of a safety enclosure Thermal-magnetic motor circuit-breakers GV ME For motor circuit-breakers and accessories: see pages 508/, 51/ and 51/. Starters consisting of a GV ME motor circuit-breaker in an enclosure conform to standard IEC GV Ithe in enclosure (A) ME 01 ME 0 ME 0 ME 0 ME 05 ME 06 ME 07 ME 08 ME 10 ME 1 ME 16 ME 0 ME ME 50077_1 GV MC Enclosures for thermal-magnetic circuit-breakers GV ME Type Degree of protection Possible number of side-mounting auxiliary contact blocks on GV ME Reference Weight LH side RH side kg Surface IP GV MC mounting, double IP 55 insulated with 1 1 GV MC protective conductor. or GV MCK0 (1) 0.0 Sealable cover IP 55 for temperature < + 5 C 1 1 GV MC Accessories common to all enclosures (to be ordered separately) Description Padlocking devices () for GV ME operator (padlocking is only possible in the O position) 1 to padlocks Ø to 8 mm Sold in lots of Unit reference Weight kg 1 GV V _1 GV K011 Mushroom head Stop pushbutton Ø 0 mm, red Sealing kit Neutral terminal Spring return () 1 GV K Latching () IP 55 For enclosures and front plate Key release, key n 55 Turn to release 1 GV K GV K GV K0 () 0.10 IP 55 for 10 GV E temperature between +5 C and +0 C IP 55 for temperature between - 0 C and + 0 C 10 GV E AB1 VV65UBL Partition 50 AB1 AC6BL 0.00 (1) Enclosure GV MCK0 is fitted with a GV K0 mushroom head Stop pushbutton as standard. () Supplied with IP 55 sealing kit. To be fitted with enclosure GV Mp01. () Padlockable in Off position using Ø to 8 mm shank padlocks EN_Ver.1.fm/

14 References (continued) TeSys enclosed starters 0 Enclosed thermal-magnetic motor circuit-breakers type GV ME and accessories Assembly of a safety enclosure Assembly of a safety enclosure (conforming to standards IEC , IEC 600 and IEC 609) Type of product Page Reference Enclosure Opposite GV MCpp Circuit-breaker 508/ GV MEpp Undervoltage trip or INRS trip (1) 51/ GV Apppp or GV AXppp Latching mushroom head Stop pushbutton Opposite GV K01 or GV K01 or GV K0 (1) Safety device for dangerous machines conforming to INRS and VDE EN_Ver.1.fm/

15 Characteristics, references TeSys enclosed starters D.O.L. starters with manual control, with magnetic circuit breaker, 0.55 to 0 kw Characteristics (1) Conforming to standards IEC 6097-, IEC 609-1, VDE and EN 6097 Degree of protection to IEC 6059 GV-LC: IP 57, GV-NGC: IP 07 Operational voltage Ue GV-LC: 690 V, GV-NGC: 500 V Material Polycarbonate () References Control by black rotary handle, padlockable in Off position (up to padlocks with Ø 8 shank, to be ordered separately) Rating Breaking capacity Icu Magnetic Reference Weight In conforming to IEC tripping 0 00 current 0 V 15 V 0 V 500 V Id ± 0 % A ka ka ka ka A kg In GV-LC GV-LC0pp In GV-LC In GV-LC In GV-LC In GV-LC In GV-LC GV-NGC0pp In GV-LC In GV-NGC In GV-NGC In GV-NGC In GV-NGC In GV-NGC06.50 Variant Starters with control by red rotary handle on yellow background Add the letter R to the end of the references selected above. Example: GV-LC006 becomes GV-LC006R. Enclosure without circuit-breaker, with rotary handle mounted on cover Description Rating Reference Weight A kg GV-LC0 Dimensions : page 110/ 110-EN_Ver.11.fm/ Schemes : page 110/ Black rotary handle GV-LC GV-NGC Red rotary handle GV-LC0R 0.00 on yellow background 5 6 GV-NGC0R (1) Circuit-breaker characteristics: - GV-L see pages 5/ and 5/ - NG 15L, product marketed under the Merlin Gerin, brand, please consult your Regional Sales Office. () Avoid placing this material in contact with harsh substances (detergents, chlorinated solvents, ketones, alcohol, aromatic hydrocarbons).

16 Dimensions, scheme TeSys enclosed starters D.O.L. starters with manual control, with magnetic circuit-breaker to 0 kw Dimensions GV-LC006 to LC00 GV-NGC05 to NGC = = 7 186, = /T1 /T = 0 = 6/T 1/L1 /L 5/L = 65 = 150 = Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO GV-LC x 1 to x 16 x 0 I x 1 or x 16 x 0 I GV-NGC x 1 or x 16 or x 0 I or x 5 I or x 1 or x 16 or x 0 I or x 5 I or x 1 or x 9 x I or x 0 I x 1 or x 9 x I or x 0 I Scheme References : page 110/ 110-EN_Ver.11.fm/

17 Characteristics, references TeSys enclosed starters D.O.L. starters for motor control (1). to 5 kw, without isolating device " Characteristics Conforming to standards IEC and IEC 9-1, VDE , EN 6097 Degree of protection to IEC 59 IP 659: LE-K, IP 657: LE/-D09 to D5 and IP 557: LE/-D05 to D955 Ambient air temperature For operation: - 5 to + 0 C Operating positions Material References Identical to positions for contactors Polycarbonate (): LE-K and LE/-D09 to D5. Sheet steel: LE/-D05 to D Non-reversing starters Standard power ratings of -phase Maximum Basic reference. Weight motors 50/60 Hz in category AC- current Complete with code 0 V 80 V 660 V I the indicating control Standard 0 V 00 V 15 V 0 V 500 V 690 V up to circuit voltage () voltages kw kw kw kw kw kw A kg LE1-D09// F7 P7 V LE1-D1// LE1-D1//Ã F7 P7 V LE1-D18// F7 P7 V LE1-D5// F7 P7 V LE1-D5// F7 P7 V LE1-D05// F7 P7 V LE1-D505// F7 P7 V LE1-D655// F7 P7 V LE1-D805// F7 P7 V LE1-D955// F7 P7 V Reversing starters LE-K065// F7 P7 V LE-K095// F7 P7 V or LE-D09// () F7 P7 V LE-D09// F7 P7 V LE-D1//Ã F7 P7 V7.100 LE-D1// LE-D18// F7 P7 V LE-D5// F7 P7 V LE-D5// F7 P7 V LE-D05// F7 P7 V LE-D505// F7 P7 V LE-D655// F7 P7 V LE-D805// F7 P7 V Dimensions: page 10/ 101_Ver.01-EN.fm/ Schemes: page 10/ LE-D955// F7 P7 V (1) Protection must be provided by addition of an overload relay, to be ordered separately, see pages 51/ and 51/. () Avoid placing this material in contact with harsh substances (detergents, chlorinated solvents, ketones, alcohol, aromatic hydrocarbons). () Standard control circuit voltages. Volts " 50/60 Hz LE-K B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 LE1, LE-D B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: please consult your Regional Sales Office. () Selection according to the number of operating cycles, please consult your Regional Sales Office.

18 References TeSys enclosed starters D.O.L. starters for motor control (1). to 5 kw, without isolating device " Description Standard versions comprise: / For non-reversing starters: 1 green Start button I, 1 red Stop/Reset button O. LE1-D1//A0 / For reversing starters: - LE-K: 1 Start button, 1 Start button, 1 red Stop/Reset button. - LE-D09 to D5: 1 -position spring return selector switch I - II, 1 red Stop/Reset button O. - LE-D05 to D955: 1 blue Reset button R. Variants (pre-assembled) Description Application Suffix to be added to the starter reference () No pushbuttons on cover LE1-D09 D955 A0 LE-D09 D955 LE1-D1//A05 1 green Start button I LE-D05 D green Start button II 1 red Stop/Reset button O 1 blue Reset button R LE1-D09 D955 A05 LE-K06 and K09 LE-D09 D position stay put selector switch ( I - O - II ) LE1-D09 D5 A09 ( I : Automatic Start; O : Stop; II : Manual Start) 1 blue Reset button R LE1-D1//A09 1 -position stay put selector switch O - I LE1-D09 D5 ( O : Stop; I : Manual Start) 1 blue Reset button R 1 -position stay put selector switch O - I with LE1-D09 D5 A5 spring return to centre position ( I : Manual start; O : Stop, stay put) 1 blue Reset button R neutral terminal LE1-D09 D955 A59 Fitted as standard on LE1 and LE-D18 to D955 LE-K06 and K09 starters ordered with 0 V (M7), 0 V (P7) LE-D09 D955 or 0 V (U7) control supply Accessory (for customer assembly) LE1-D1// Description Application Reference Weight kg Start pushbutton latching device LE1-D05 D955 LA9-D for stay put operation (Start-Stop) (1) See previous page. () Example: LE1-D09F7A LE1-D1//A5 Schemes: page 10/ Other versions Possible combinations of variants. Please consult your Regional Sales Office. 101_Ver.01-EN.fm/

19 Dimensions TeSys enclosed starters D.O.L. starters for motor control. to 5 kw, without isolating device LE1-D09 and D1 LE1-D18 to D5 LE1-D05 to D655 LE-D09 to D5 c1 166 = = 88 = 150 = c1 01 = = = 195 = c1 = = c1 c1 c1 LE1-D LE-D Standard version 18.5 Standard version Standard version 161 Version A0 10 Version A Version A0 150 Version A Version A Version A Version A09 15 Version A Version 15 Version 160 Version A5 15 Version A5 160 LE-K06 and K LE1-D805 and D955 LE-D05 to D655 LE-D805 and D955 c1 07 = = = 165 = 87 c1 = 5 = 67 = 195 = c1 c1 LE1-D LE-D Standard version Standard version 19 Version A Version A0 190 Version A Version A05 19 Version Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE1-D09 and D1 x 1 or x 16 x 0 I x 1 or x 16 x 0 I LE1-D18 to D5 and LE-D09 to D5 x 16 or x 1 x 0 I or x 5 I x 16 or x 1 x 0 I or x 5 I LE-D05 1 x 1 and 1 x 1 1 x 0 I and 1 x 5 I 1 x 1 and x 1 1 x 0 I and x 5 I LE1-D05 to D655 and LE-D505 and D655 1 x 1 and 1 x 9 1 x 0 I and 1 x I 1 x 1 and x 9 1 x 0 I and x I LE1 or LE-D805 and D955 1 x 1 and 1 x 6 1 x 0 I and 1 x 0 I 1 x 1 and x 6 1 x 0 I and x 0 I LE-K x 1 and x 16 x 0 I x 1 and x 16 x 0 I References : pages 101/ and 101/ Schemes : page 101/ 10_Ver.10-EN.fm/

20 Schemes TeSys enclosed starters D.O.L. starters for motor control. to 5 kw, without isolating device LE1-D09 to D955 LE1-D09 to D955 Variant A0 or A05 A L1 L U V W L A B I O A B O Remote control l A LE-K06, K09 LE-K06, K09 Variant A05 A A L1 L L R O Remote control KM KM KM KM KM KM U V W B A A B A A LE-D09 to D955 LE-D09 to D5 LE-D05 to D955 LE-D09 to D955 with variants A0 or A05 L1 L L A A R 1 O S1 I II l Remote control l l KM KM KM KM KM KM KM U V W B A A B A A References : pages 101/ and Connections A B 0 V, 0 V, 0 V LE-K, LE1 and LE-D09 and D1 L Neutral LE1 and LE-D18 to D955 L Neutral terminal 80 V, 00 V, 15 V, 0 V All products L L1 Other voltages LE1 and LE-D09 to D5 Terminal 1 Terminal LE-K, LE1 and LE-D05 and D955 Direct connection 101/ page 10/ Dimensions : 10_Ver.10-EN.fm/

21 Characteristics, references TeSys enclosed starters D.O.L. starters for motor control (1). to 5 kw, with isolating device " Characteristics Conforming to standards IEC and IEC 9-1, VDE , EN 6097 Degree of protection to IEC 59 IP 659 : LE/-K, IP 657 : LE/-D09 to D5 and IP 55 : LE/-D06 to D806 Ambient air temperature For operation : - 5 to + 0 C Operating positions Material References Identical to positions for contactors Polycarbonate () : LE/-K and LE/-D09 to D5. Sheet steel : LE/-D06 to D806 Non-reversing starters Standard power ratings of -phase Current Fuses Basic reference. Weight motors 50/60 Hz in category AC- I the to be fitted by Complete with code 0 V 80 V 660 V max. the customer indicating control Standard 0 V 00 V 15 V 0 V 500 V 690 V up to Size Type am circuit voltage () voltages kw kw kw kw kw kw A A kg x 8 10 LE-K065// F7 P7 V x 8 1 LE-K095// F7 P7 V or LE-D09// () F7 P7 V x 8 1 LE-D09// F7 P7 V x 8 16 LE-D1// F7 P7 V LE-D1// x 8 0 LE-D18// F7 P7 V x 8 5 LE-D5// F7 P7 V x 51 LE-D5// F7 P7 V x 51 0 LE-D06// F7 P7 V x 58 6 LE-D506// F7 P7 V x LE-D656// F7 P7 V x LE-D806// (5) F7 P7 V Reversing starters x 8 10 LE8-K065// F7 P7 V x 8 1 LE8-K095// F7 P7 V or LE8-D09// () F7 P7 V x 8 1 LE8-D09//Ã F7 P7 V x 8 16 LE8-D1// F7 P7 V x 8 0 LE8-D18// F7 P7 V x 8 5 LE8-D5// F7 P7 V x 51 LE8-D5// F7 P7 V x 51 0 LE-D06// F7 P7 V LE8-D1// x 58 6 LE-D506// F7 P7 V x LE-D656// F7 P7 V Dimensions : page 10/ 10_Ver.10-EN.fm/ Schemes : page 10/ x LE-D806// F7 P7 V (1) Protection must be provided by addition of an overload relay, to be ordered separately, see pages 51/ and 51/. () Avoid placing this material in contact with harsh substances (detergents, chlorinated solvents, ketones, alcohol, aromatic hydrocarbons). () Standard control circuit voltages. Volts " 50/60 Hz LE/-K B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 LE/-D B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 Other voltages : please consult your Regional Sales Office. () Selection according to dimensions and number of operating cycles, please consult your Regional Sales Office. (5) Supplied with cable entries.

22 References TeSys enclosed starters D.O.L. starters for motor control (1). to 5 kw, with isolating device " Description Standard versions comprise : /ÃÃFor non-reversing starters : - LE-K and LE-D09 to D656 : 1 green Start button I, 1 red Stop/Reset button O, - LE-D806 : no pushbuttons on cover. /ÃFor reversing starters : - LE8-K : 1 Start button, 1 Start button, 1 red Stop/Reset button, - LE8-D09 to D5 : 1 -position spring return selector switch I II, 1 red Stop/Reset button O, LE-D1//A0 - LE-D06 to D806 : no pushbuttons on cover. Protection Power circuit Control circuit LE and LE8-K 1 -pole isolating device None LE and LE8-D09 to D5 1 -pole isolating device + 1 additional pole LA8-D5 LE and LE-D06 to D pole isolating device + 1 circuit-breaker GB-CB08 Variants (pre-assembled) Description Application Suffix to be added to the starter reference () No pushbuttons on cover LE-D09 D656 A0 LE8-D09 D5 1 green Start button I LE-D06 D green Start button II 1 red Stop/Reset button O LE-D1//A05 1 blue Reset button R LE-D09 D806 A05 LE8-K06 and K09 LE8-D09 D5 LE-D06 D806 1 neutral terminal LE-K06 and K09 A59 Fitted as standard on starters LE-D18 to D806, LE-D09 D806 LE8-D18 to D5 and LE-D06 to D806 LE8-K06 and K09 ordered with 0 V (M7), 0 V (P7) and 0 V (U7) LE8-D09 D5 control supply LE-D06 D806 Accessories (for customer assembly) Description Application Reference Weight kg Start pushbutton latching device LE-D06 D656 LA9-D for stay put operation (Start-Stop) (1) See previous page () Example : LE-D09F7A0. Schemes : page 10/ Other versions Possible combinations of variants. Please consult your Regional Sales Office. 10_Ver.10-EN.fm/

23 Dimensions TeSys enclosed starters D.O.L. starters for motor control. to 5 kw, with isolating device LE-K06 and K09 LE8-K06 and K09 1 LE-D09 to D5 LE8-D09 to D c1 150 (1) c1 8 = 0 = = = c1 c1 LE-K LE8-K LE-D LE8-D Standard version Standard version Version A05 19 Version A Version A (1) For LE8 only. LE-D06 to D = c1 = 5 = 67 = 1 c1 Standard version 01 Version A0 190 Version A05 01 LE-D06 to D806 LE-D806 = a-75 = 1 00 (1),5 50 xm8x5 5 = = LE- a D06, D506, D D LE- a D c1 (1) + 1 mm with blanking plugs. a-50 a a+57,5 c1 LE-D LE-D Standard version Version A Version 1 18 Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE and LE8-D09 to D5 x 1 or x 16 or x 0 I or x 5 I or x 1 or x 16 or x 0 I or x 5 I or x 1 or x 9 x I or x 0 I x 1 or x 9 x I or x 0 I LE-D09 to D5 1 x 16 or x 1 x 0 I or x 5 I x 16 or x 1 x 0 I or x 5 I LE-D06 and LE-D06 1 x 1 and 1 x 1 1 x 0 I and 1 x 5 I 1 x 1 and x 1 1 x 0 I and x 5 I LE1-D506 to D656 and LE-D506 and D6561 x 1 and 1 x 9 1 x 0 I and 1 x I 1 x 1 and x 9 1 x 0 I and x I LE-D806 and LE-D806 1 x 1 and 1 x 6 1 x 0 I and 1 x 0 I 1 x 1 and x 6 1 x 0 I and x 0 I LE-K, LE8-K x 1 and x 16 x 0 I x 1 and x 16 x 0 I References : pages 10/ and 10/ Schemes : page 10/ 10_Ver.10-EN.fm/

24 Schemes TeSys enclosed starters D.O.L. starters for motor control. to 5 kw, with isolating device LE-K06, K09 LE-D09 to D806 LE-K06, K09 LE-D09 to D5 LE-D06 to D656 LE-D806 LE-D09 to D656 with variant A0 or A05 Q1 L1 L L A A Q1 Q1 A F1 Q1 A F1 Q1 I B O A I O A B l O A B l O Remote control A L1 L L A A Q1 R Q1 O KM KM KM KM U V W LE8-K06, K09 LE8-K06, K09 Variante A05 Remote control KM KM U V W B A A B A A LE8-D09 to LE-D806 LE8-D09 to D5 LE-D06 to D806 L1 L L A Q1 Q1 A F1 Q1 Q1 O O 1 KM S1 I II l Remote control 1 1 l l 1 1 KM KM KM KM KM KM U V W B A A B A A References : pages 10/ and 10/ Connections A B 0 V, 0 V, 0 V LE and LE8-K, LE and LE8-D09 and D1 L Neutral LE-D18 to D806, LE8-D18 to D5 and LE-D06 to D806 L Neutral terminal 80 V, 00 V, 15 V, 0 V All products L L1 Other voltages LE and LE8-D09 to D5 Terminal 1 Terminal LE and LE-D06 and D806 Direct connection Dimensions : page 10/ 10_Ver.10-EN.fm/

25 Characteristics, references TeSys enclosed starters D.O.L. starters for motor control 0.5 to 7.5 kw with -phase thermal overload relay Characteristics Conforming to standards IEC 97--1, IEC 9-1, VDE and EN 6097 Degree of protection to IEC 59 IP 65 Ambient air temperature For operation: - 5 to + 0 C Operating positions Material References Identical to those for k contactors Self-extinguishing ABS Non-reversing starters Starter LE1-M, combined with short-circuit protection components, provides type 1 or type coordination, depending on the type of devices used. Standard power ratings Setting range Basic reference. Weight of -phase motors 50/60 Hz in category AC- of thermal overload Complete with code 0 V 80 V relay LR-K(1) indicating power 0 V 0 V 00 V 15 V circuit voltage () kw kw kw kw A kg LE1-M5// LE1-M5// LE1-M5// LE1-M5// LE1-M5// LE1-M5// LE1-M5// LE1-M5// LE1-M5//// Description LE1-M5// LE1-M5// / The standard version comprises: - 1 green Start button I, - 1 red Stop/Reset button O/R, - 1 yellow operating indicator. / Control may be pulsed or maintained. / An earth terminal and a neutral terminal are provided on the bottom of the enclosure. Variant Starter without thermal overload relay LR-K Delete the last digits of the starter references selected above. Example: LE1-M5// Spare part Description Basic reference. Complete Weight with code indicating power circuit voltage () kg Contactor LC1-K//A Dimensions : page 105/ 105_Ver.10-EN.fm/ (1) Thermal overload relay fitted as standard. () The contactor coil is pre-wired between phases of the power circuit The codes indicated below therefore correspond to the power circuit voltage. Volts " 50/60 Hz Code B7 M7 P7 U7 Q7 V7 N7 R7 Example: 80/00 V -phase supply, kw motor: LE1-M5Q716 Schemes : page 105/

26 Dimensions, schemes TeSys enclosed starters D.O.L. starters for motor control 0.5 to 7.5 kw with -phase thermal overload relay Dimensions LE1-M5 (1) (5"1/8) Knock-outs or blanking plugs for cable glands Enclosure type At top At bottom PG ISO PG ISO LE1-M x 1 to x 1 x 0 I or x 5 I x 1 to x 1 x 0 I or x 5 I (1) Can be mounted on machine panel or frame. Knock-outs for x 1 P cable glands. Schemes LE1-M5 Choice of type of control built into the product Control by Control by latching spring return pushbuttons pushbuttons L1 L L 1/L1 /L 5/L A A I I I KM or 6 1 A 6 O O/R O/R Reset/OR U V W A H A H1 6 M T1 T T B B Connections A B 0 V, 0 V, 0 V L Neutral 80 V, 00 V, 15 V, 0 V L L1 Other voltages Terminal 1 Terminal References : page 105/ 105_Ver.10-EN.fm/

27 Characteristics, references TeSys enclosed starters D.O.L. starters for motor control 0.7 to 5.5 kw with thermal magnetic circuit-breaker and contactor Characteristics Conforming to standards IEC 97--1, IEC 9-1, VDE and EN 6097 Degree of protection to IEC 59 IP 55 Ambient air temperature For operation: - 5 to + 0 C Operating positions Identical to those for K contactors Material Polycarbonate (1) References Standard power ratings of -phase Setting Fixed Basic reference. Weight motors 50/60 Hz in category AC- range of magnetic Complete with code 00 thermal tripping indicating control 0 V 15 V 0 V 500 V 690 V trips current 1 Irth circuit voltage () kw kw kw kw kw A A kg LE1-GVME06K// LE1-GVME07K// LE1-GVME08K// LE1-GVME10K// LE1-GVME1K// LE1-GVME//K// Variant LE1-GVME16K// Description Suffix to be added to the starter reference () Weight kg Neutral terminal A59 Description Reference Weight kg LE1-GVMEK Enclosure without starter, LE1-GVMEK 0.70 with sealing kit fitted (references of combination motor starters for customer assembly, see pages 50/ and 50/) Accessories (to be ordered separately) Description Sold in lots of Unit reference Weight kg Dimensions : page 111/ 111_Ver.10-EN.fm/ Padlocking device () 1 to padlocks with 1 GV-V for padlocking the Ø to 8 mm shank GV-ME operator (Padlocking is only possible in the O (Off) position) Mushroom Spring return () 1 GV-K head Stop button Latching Key release (key n 55) 1 GV-K Ø 0 mm, () IP 55 Turn to release 1 GV-K red 1 GV-K0 (5) 0.10 Sealing IP GV-E kit IP 55 for θ < + 5 C 10 GV-E (1) Avoid placing this material in contact with harsh substances (detergents, chlorinated solvents, ketones, alcohol, aromatic hydrocarbons). () Standard control circuit voltages Volts " 50/60 Hz Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: please consult your Regional Sales Office. () Example: LE1-GVME06KF7A59 () Supplied with IP 55 sealing kit. (5) Padlockable in position O, by padlock with Ø to 8 mm shank. Schemes : page 111/

28 Dimensions, schemes TeSys enclosed starters D.O.L. starters for motor control 0.7 to 5.5 kw with thermal magnetic circuit-breaker and contactor Dimensions LE1-GVMEK = = 101 Schemes LE1-GVMEK A L1 L L Q1 Q1 O External control I B A Connections A B 0 V, 0 V, 0 V L Neutral 80 V, 00 V, 15 V, 0 V L L1 Other voltages Terminal 1 Terminal References : page 111/ 111_Ver.10-EN.fm/

29 Characteristics, references TeSys enclosed starters Star-delta starters 5.5 to 1 kw, without isolating device (1) " Characteristics Conforming to standards IEC and IEC 9-1, VDE , EN 6097 Degree of protection to IEC 59 IP 659: LE-K, IP 657: LE-D09 to D5 and IP 557: LE-D05 to D150 Ambient air temperature For operation: - 5 to + 0 C Operating positions Material References Identical to positions for contactors Polycarbonate (): LE-K and LE-D09 to D5. Sheet steel: LE-D05 to D150 Standard power ratings Basic reference. Weight of squirrel cage motors Complete with code Mains voltage - delta connection indicating control 0 V 80 V 15 V 0 V circuit voltage 00 V () kw kw kw kw kg Maximum operating rate LE -K: 1 starts/hour and LE-D: 0 starts/hour. Maximum starting time: 0 seconds. LE-D: an LAD-S timer imposes a delay of 0 ms ± 15 ms on the delta contactor at the moment of changeover to ensure that the star contactor has sufficient breaking time LE-K065// 1.60 LE-D1// LE-K095// 1.60 or LE-D09// () LE-D1// LE-D18// LE-D5// LE-D05// LE-D505// LE-D805// LE-D115// LE-D150//.500 (1) Protection must be provided by the addition of an overload relay, to be ordered separately. Select appropriate overload relay for setting at 0.58 of the full load rated motor current, see pages 51/ and 51/. () Avoid placing this material in contact with harsh substances (detergents, chlorinated solvents, ketones, alcohol, aromatic hydrocarbons). () Standard control circuit voltages. Volts " 50/60 Hz LE-K B7 D7 E7 F7 M7 P7 U7 LE-D B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: please consult your Regional Sales Office. () Selection according to dimensions and the number of operating cycles, please consult your Regional Sales Office. Dimensions : page 107/ Schemes : page 107/ 106-EN_Ver.1.fm/

30 References TeSys enclosed starters Star-delta starters 5.5 to 1 kw, without isolating device " Description The standard version comprises: - LE-K and LE-D09 to D5: 1 green Start button I 1 red Stop/Reset button O - LE-D05 to D150: no pushbuttons on cover. Variants (pre-assembled) Description Application Suffix to be added to the starter reference (1) No pushbuttons on cover LE-D09 D5 A0 1 green Start button I LE-D05 D150 A06 1 red Stop/Reset button O LE-D1//A0 1 blue Reset button R LE-D09 D805 A05 1 neutral terminal LE-K065 and K095 A59 Fitted as standard on starters LE-D09 D805 LE-D115 and D150 LE-D1//A05 Mechanical interlock LE-D05 to D150 A6 Fitted as standard on starters LE-K and LE-D09 to D5 (1) Example: LE-D09F7A0 Other versions Possible combinations of variants. Please consult your Regional Sales Office. Schemes : page 107/ 106-EN_Ver.1.fm/

31 Dimensions TeSys enclosed starters Star-delta starters 5.5 to 1 kw, without isolating device LE-K065, K LE-D09 to D c1 8 = = 186 = 0 = c1 Standard version Version A0 167 Version A LE-D05 and D c1 = 5 = 67 = 195 = c1 Standard version 190 Version A05 19 Version A06 19 LE-D805 to D150 = a - 75 = b (1) b + 57,5 b - 50 b - 75 = LE- a b D D D c1 c1 + 15,5 a - 50 a a + 57,5 = c1 LE-D805 LE-D115, D150 Standard version 0 5 Version A05 18 Version A (1) + 1 mm with blanking plugs. Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE-D09 to D5 x 1 or x 16 or x 0 I or x 5 I or x 1 or x 16 or x 0 I or x 5 I or x 1 or x 9 x I or x 0 I x 1 or x 9 x I or x 0 I LE-D05 1 x 9 1 x I 1 x 9, x 1 and x 1 1 x I, x 0 I and x 5 I LE-D505 1 x 6 1 x 0 I 1 x 6, x 1 and x 9 1 x 0 I, x 0 I and x I LE-D805 1 x 6 1 x 0 I x 1 and x 6 x 0 I and x 0 I LE-K x 1 and x 16 x 0 I x 1 and x 16 x 0 I References : pages 106/ and 106/ 107_Ver.0-EN.fm/

32 Schemes TeSys enclosed starters Start-delta starters 5.5 to 1 kw, without isolating device LE-K065 and K095 LE-K065 and K095 L1 L L A U1 V1 W1 O KM KM U V W I KM U1 V1 W1 KM U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). B T A T A Y A KM KM A L LE-D09 to D805 LE-D09 to D5 LE-D05 to D805 L1 L L A A Ð KM Ð KM Ð KM1 U1 V1 W1 O U1 V1 W1 U V W I KM Remote control I KM KM KM KM KM U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). B KM U1 V1 W1 A Y KM A L KM A B KM A Y KM A L KM A Note : in accordance with current installation regulations, short-circuit protection must be provided by fuses or a circuit-breaker. LE-D115 and D150 LE-D115 and D150 L1 L L A Ð KM Ð KM Ð KM1 U1 V1 W1 U V W Remote control l KM KM U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). B F KM A Y KM A L KM K A K KM A References : pages 106/ and 106/ Dimensions : Connections A B 0 V, 0 V, 0 V LD09 and D1 L Neutral LE-D18 to D150 L Neutral terminal 80 V, 00 V, 15 V, 0 V All products L L1 Other voltages LE-D09 to D5 Terminal 1 Terminal LE-K and LE-D05 to D150 Direct connection page 107/ 107_Ver.0-EN.fm/

33 Characteristics, references TeSys enclosed starters Star-delta starters (1) 7.5 to 75 kw with isolating device " Characteristics Conforming to standards IEC and IEC 9-1, VDE , EN 6097 Degree of protection to IEC 59 IP 657: LE6-D09 to D18 and IP 557: LE-D6 to D806 Ambient air temperature For operation: - 5 to + 0 C Operating positions Material References Identical to positions for contactors Polycarbonate (): LE6-D. Sheet steel: LE-D Standard power ratings Fuses to be fitted Basic reference. Weight of squirrel cage motors by the customer Complete with code Mains voltage - Delta connection Size Type indicating control 0 V 80 V 15 V 0 V am circuit voltage Standard 00 V () voltages kw kw kw kw A kg Maximum operating rate: 0 starts/hour. Maximum starting time: 0 seconds. An LAD-S timer imposes a delay of 0 ms ± 15 ms on the delta contactor at the moment of changeover to ensure that the star contactor has sufficient breaking time x 8 0 LE6-D09// F7 P7 V7.900 LE6-D1// x 8 5 LE6-D1// F7 P7 V x 51 0 LE6-D18// F7 P7 V x 58 6 LE6-D6// F7 P7 V x LE-D06// F7 P7 V x LE-D506// F7 P7 V LE-D806// F7 P7 V (1) Protection must be provided by the addition of an overload relay, to be ordered separately. Select appropriate overload relay for setting at 0.58 of the full load rated motor current, see pages 51/ and 51/. () Avoid placing this material in contact with harsh substances (detergents, chlorinated solvents, ketones, alcohol, aromatic hydrocarbons). () Standard control circuit voltages. Volts /60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: please consult your Regional Sales Office. Dimensions : page 109/ 108_Ver.10-EN.fm/ Schemes : page 109/ :

34 References TeSys enclosed starters Star-delta starters 7.5 to 75 kw with isolating device " Description The standard version comprises: - LE6-D09 to D18: 1 green Start button I 1 red Stop/Reset button O - LE-D6 to D806 no pushbuttons on cover Protection Power circuit Control circuit LE6-D09 and D1 1 -pole isolating device + 1 additional pole LA8-D5 LE6-D18 to LE-D pole isolating device + 1 circuit breaker GB-CB08 Variants (pre-assembled) Description Application Suffix to be added to the starter reference (1) No pushbuttons on cover LE6-D09 D18 A0 1 green Start button I LE-D6 to D806 A06 1 red Stop/Reset button O LE6-D1//A0 1 blue Reset button R LE6-D09 LE-D806 A05 1 neutral terminal LE6-D09 D806 A59 LE6-D1//A05 Mechanical interlock LE-D6 D806 A6 Fitted as standard on starters LE6-D09 to D18 (1) Example: LE6-D09F7A0. Schemes : page 109/ 108_Ver.10-EN.fm/

35 Dimensions TeSys enclosed starters Star-delta starters 7.5 to 75 kw, with isolating device LE6-D09 to D18 LE-D6 c1 8 = 0 = = = = = 5 = = 1 c1 Standard version Version A0 167 Version A LE-D06 to D806 = a-75 = 1 = b (1) b+57,5 b-50 b-75 = xm8x5 c1 a-50 a a+57,5 LE- a b c1 D06, D D (1) + 1 mm with blanking plugs. Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom PG ISO PG ISO LE6-D09 to D18 x 1 or x 16 or x 0 I or x 5 I or x 1 or x 16 or x 0 I or x 5 I or x 1 or x 9 x I or x 0 I x 1 or x 9 x I or x 0 I LE-D6 1 x 1 1 x I x 1, x 16 & 1 x 1 x 0 I, x 5 I &1 x I LE-D06 1 x 9 1 x I x 1, x 1 & 1 x 9 x 0 I, x 5 I & 1 x I LE-D506 1 x 6 1 x 0 I x 1, x 9 & 1 x 6 1 x 0 I, x 0 I & x I LE-D806 1 x 6 1 x 0 I x 1 & x 6 x 0 I and x 0 I References : pages 108/ and 108/ Schemes : page 109/ 109_Ver.10-EN.fm/

36 Schemes TeSys enclosed starters Star-delta starters 7.5 to 75 kw, with isolating device LE6-D09 to D18 LE6-D09 to D18 Q1 1/L1 /L 5/L 6 U1 V1 6 W1 A Q1 Q O KM KM U 6 6 V W U1 V1 6 W1 l KM U V W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). KM KM KM KM KM B A A A LE-D6 to D806 LE-D6 to D806 1/L1 /L 5/L 6 A Q1 6 U1 V1 W1 F1 Q KM KM U V W S Remote control 1 U1 V1 W1 1 5 l 1 KM U V W 6 Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). KM KM KM KM KM B A A A References : pages 108/ and 108/ Dimensions : page 109/ Connections A B 0 V, 0 V, 0 V LE6-D09 and D1 L Neutral LE6-D18 to LE-D806 L Neutral terminal 80 V, 00 V, 15 V, 0 V All products L L1 Other voltages LE6-D09 to D18 Terminal 1 Terminal LE-D6 to D806 Direct connection 109_Ver.10-EN.fm/

37 References TeSys enclosed starters Replacement parts for starters without isolating device _1 Heads for Start and Stop/Reset pushbuttons Description For use on Unit reference Weight kg Flush, green I (1) LE1-D09...D5 ZB5-AA Projecting, red O (1) LE1-D09...D5 ZB5-AL ZB5-AA _1 Adaptation kit for head ZB5-AL LE1-D09 and D1 LAD LE1-D18...D5 LAD ZB5-AL Heads for Reset pushbuttons Flush, blue R () LE1-D09...D5 ZB5-AA ZBA-69 () _1 Adaptation kit for head ZB5-AA0 + ZBA-69 LE1-D09 and D1 LAD LE1 or LE-D18...D5 LAD LAD-9091 LE, LE6, LE or LE8-D09...D5 Heads for selector switches LAD-9T _1 position stay put LE1-D09...D5 ZB5-AD 0.0 position stay put LE1-D09...D5 ZB5-AD 0.0 ZB5-ADp position spring return to centre LE1-D09...D5 ZB5-AD _1 Contact blocks 1 N/O spring return LE1-D09...D5 ZEN-L ZEN-L N/C spring return LE1-D09...D5 ZEN-L _1 Mounting for contact block LE1-D09 and D1 LAD LEp-D18...D5 () LAD LAD (1) Do not forget to order adaptation kit LAD-9091 or LAD-91810, depending on size. () Do not forget to order adaptation kit LAD-909. () Sold in lots of 10. () LE1, LE, LE, LE, LE6 or LE8. 10-EN_Ver1..fm/

38 References TeSys enclosed starters Replacement parts for starters without isolating device Empty enclosures for D.O.L. starters without isolating device Intended usage Head(s) mounted on cover Reference Weight kg LE1-D09, D1 Without DE1-DS1A flush blue head R DE1-DS1A DE1-DS1A flush green head I DE1-DS projecting red head O 1 flush blue head R 1 switch DE1-DS DE1-DS1A LE1-D18...D5 Without DE1-DSA flush blue head R DE1-DSA DE1-DS flush green head I DE1-DS projecting red head O 1 flush blue head R 1 switch DE1-DS DE1-DS1 10-EN_Ver1..fm/

39 References Enclosed starters Star-delta starters (1) 90 to 75 kw, without isolator " Standard power ratings Basic reference. Weight of squirrel cage motors () Complete with code Mains voltage - delta connection indicating control Usual 0 V 80 V 15 V 0 V circuit voltage ()() voltages kw kw kw kw kg Maximum operating rate : 1 starts/hour. Maximum starting time : 0 seconds LE-F185// F7 P7 V LE-F5// F7 P7 V LE-F65// F7 P7 V LE-F0// F7 P7 V LE-F00// F7 P7 V Specifications Enclosure LE-F185 to F00 Metal enclosure, IP 559 LE-F No pushbuttons on cover LE-F185 to F00 Connections LE-F185 to F00 Pre-wired power and control circuit connections Variants (mounted by Telemecanique) Description For Suffix to be added use on to starter reference () 1 green Start button I LE-F185 to F00 A06 1 red Stop/Reset button O (1) Protection must be provided by the addition of a thermal overload relay, to be ordered separately. Select appropriate overload relay for setting at 0.58 the full load rated motor current, see pages 707/ to 707/. () Standard control circuit voltages (variable delivery time, please consult your Regional Sales Office). Volts / / /60 Hz E7 F7 M7 P7 U7 Q7 V7 N7 For other voltages, see replacement coil pages 501/ to 501/9. () LC1-F185 and F5 : contactors fitted with LX9-F coils; LC1-F65 F00 : contactors fitted with LX1-F coil. () Example : LE-F185M7A06 Dimensions : page 5017/ Schemes : page 5017/ Other versions Possible combinations of variants. Please consult your Regional Sales Office. 5017_Ver.0-EN.fm/

40 Dimensions, schemes Enclosed starters Star-delta starters 90 to 75 kw, without isolator Dimensions LE-F/// = a-75 = = b (1) b+57,5 b-50 b-75 = xm8x5 c c1 a-50 a a+57,5 LE- a b () c c1 Knock-outs or blanking plugs for cable glands F185, F F Enclosure At At F0, F type top bottom LE-F185, F5 x 8 P x 1 P and x 8 P LE-F65 to 00. (1) + 1 mm with blanking plugs Schemes LE-F/// F1 L1 L L 6 KM:5 U1 V1 W1 KM KM F1 96 U V W Remote control l O KM 5 5 U1 U V1 V W1 W Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). KM:1 F KM 6 61 KM 5 (1) (1) KM A A KM K A KM 1 K 1 A Note : in accordance with current installation regulations, short-circuit protection must be provided by fuses or a circuit breaker. References : page 5017/ 5017_Ver.0-EN.fm/

41 References Enclosed starters D.O.L. starters and equipment, without isolator Equipment for control in utilisation category AC-1, (1), () a Opera- Minimum Fuses to For use with Basic reference. Weight tional c.s.a. be fitted relay LR-D Complete with code current of separately or kit LA9-D indicating control up to phase (to be ordered circuit Usual conductors am gg separately) voltage () voltages A mm A A kg LA9-D175 () LE1-D1pp M7 Q LR-D11 () LE1-D1pp M7 Q LE1-D1.5 5 LR-D1 () LE1-D55pp M7 Q LA9-D0975 () LE1-D55pp M7 Q LE1-D05ppA0 (5) M7 Q LR-D59 () LE1-D05pp M7 Q LE1-D655ppA0 (5) M7 Q7.850 LE1-D LR-D6 () LE1-D655pp M7 Q LR-D65 () LE1-D805pp M7 Q LE1-D805ppA0 (5) M7 Q Specifications Enclosure LE1-D1 Double insulated, degree of protection IP 659 LE1-D5 Double insulated, degree of protection IP 557 LE1-D0 D80 Metal, degree of protection IP 559 Control ( pushbuttons mounted on enclosure cover) LE1-D1 D80 1 green Start button I 1 red Stop/Reset button O No pushbuttons on cover LE1-DpppppA0 Connections LE1-D1 D80 Pre-wired control circuit connections (1) -phase 0/0 V or 80/00 V or 15 V 50/60 Hz. -core or + N (unprotected neutral) insulated PVC cable, fixed to walls, in cable racks or ducting, laid singly, ambient temperature 5 C, conforming to NF C () Control circuit voltage 0/0 V 50/60 Hz (code M7) or 80/00 V (code Q7). () Order the required LR-D thermal overload relay separately. For use on balanced circuits only. () As protection is provided by type gg fuses only, the Stop function normally provided by the thermal overload relay (where am type fuses are used) can be obtained by means of kit LA9-Dpp75. (5) Equipment supplied without pushbuttons; external Start-Stop station required. Dimensions : page 0/ Schemes page 0/ 0-EN_Ver.1.fm/

42 References Enclosed starters D.O.L. starters and equipment, without isolator Equipment for control in utilisation category AC-1, (1), () Variants (pre-mounted) Description For Suffix to be added use on to the reference () No pushbuttons on cover LE1-D1 & D5 A0 1 blue Reset button R LE1-D1 D80 A05 1 green Start button I and 1 red Stop LE1-D1 & D5 A07 button "O with 1 N/C contact (for distribution circuits without thermal overload relay) 1 -position selector switch "O-I LE1-D1 ("O : Stop ; "I : Manual Start) 1 blue Reset button "R Knock-outs for x 16 mm plastic cable glands LE1-D1 A0 (instead of x 1 plastic glands) 1 neutral terminal (-phase + N circuits) LE1-D1 D80 A59 Accessories (mounted by the customer) Description For Reference Weight use on kg Start button latching device LE1-D5 D65 LA9-D for stay put operation (Start-Stop) Kits to provide stop function without LE1-D1 LA9-D thermal overload relay fitted LE1-D5 LA9-D Miniature control LE1-D1 LA9-D circuit fuse holder size 5 x 0 A /50 V Fuse supplied LE1-D5 LA9-D Pilot light with neon bulb, 110 V LE1-D1 & D5 LA9-D red lens and locking ring 0 V LE1-D1 & D5 LA9-D , 15 V LE1-D1 & D5 LA9-D front-mounting block LE1-D1 D80 L-DNpp 0.00 of auxiliary contacts Please consult your Regional Sales Office (1) -phase 0/0 V or 80/00 V 50/60 Hz. -core or + N (unprotected neutral) insulated PVC cable, fixed to walls, in cable racks or ducting, laid singly, ambient temperature 5 C, conforming to NF C () Order the required LR-D thermal overload relay separately. For use on balanced circuits only. () Example: LE1-D1M7A0. Schemes: page 0/ Other versions Possible combinations of variants. Please consult your Regional Sales Office. 0-EN_Ver.1.fm/

43 Dimensions Enclosed starters D.O.L. starters and equipment, without isolator LE1-D1 LE1-D55 LE1-D05, D = = 88 = 150 = = = 101 = 165 = (1) 1 = = = 195 = (1) 150 for LE1-DpppppA0 (without pushbuttons). LE1-D = 165 = 165 c1 = = Knock-outs or blanking plugs for cable glands Type of enclosure At top At bottom LE1-D1 x 1 P x 1 P LE1-D55 1 x 1 P and 1 x 16 P x 16 P LE1-D and LE1-D655 1 x 1 P and 1 x 9 P 1 x 1 P and x 9 P LE1-D805 1 x 1 P and 1 x 6 P 1 x 1 P and x 6 P References : pages 0/ and 0/ Schemes : page 0/ 0-EN_Ver.11.fm/

44 Schemes Enclosed starters D.O.L. starters and equipment, without isolator D.O.L. starters and equipment for control in category AC-1 LE1-D1 to D805 LE1-D1 LE1-D55 to D805 LE1-DpppppA0, LE1-DpppppA05 LE1-DpppppA0 KM1/5 1/L1 /L U V 1 W /L KM1/5 I N KM1/1 1 1 O A KM1/5 l N KM1/ O A Remote control N KM1/1 l O A References : pages 0/ and 0/ Dimensions : page 0/ 0-EN_Ver.11.fm/

45 References Enclosed starters D.O.L. starters and equipment, with off-load isolator Equipment for control in utilisation category AC-1, (1), () a Operational Minimum Fuses to be For use with Basic reference. Weight current c.s.a. fitted by customer relay LR-D Complete with code up to of or kit LA9-D indicating control phase Size Type (to be ordered circuit Usual conductors am gg separately) voltage () voltages A mm A A kg x 8 16 LA9-D0975 () LE-D16pp M7 Q x 8 0 LR-D11 () LE-D16pp M7 Q x 8 0 LA9-D0975 () LE-D56pp M7 Q x 8 5 LR-D1 () LE-D56pp M7 Q x 51 0 LE-D06ppA0 (5) M7 Q LE-D x LR-D57 () LE-D06pp M7 Q x 58 6 LE-D656ppA0 (5) M7 Q x LR-D6 () LE-D656pp M7 Q x LR-D65 () LE-D806pp (5) M7 Q x LE-D806pp (5) M7 Q Specifications Enclosure LE-D1 and D5 Double insulated, degree of protection IP 557 LE-D0 D80 Metal, degree of protection IP 559 Control ( pushbuttons LE-D1 D65 1 green Start button I mounted on enclosure cover) 1 red Stop/Reset button O No pushbuttons on cover LE-Dppppp A0 LE-D80 Isolator with LE-D1 and D5 1 -pole isolator + 1 additional pole LA8-D5 external operator LE-D06 LE-D0 D80 1 -pole isolator + 1 circuit breaker GB-CB08 Connections LE-D1 D80 Pre-wired power and control circuit connections (1) -phase 0/0 V or 80/00 V 50/60 Hz. -core or + N (unprotected neutral) insulated PVC cable, fixed to walls, ceilings, in cable racks or ducting, laid singly, ambient temperature 5 C, conforming to NF C () Control circuit voltage 0/0 V 50/60 Hz (code M7) or 80/00 V (code Q7). () Order the required LR-D thermal overload relay separately. For use on balanced circuits only. () As protection is provided by type gg fuses only, the Stop function normally provided by the thermal overload relay (where am type fuses are used) can be obtained by means of kit LA9-D0975. (5) Equipment supplied without pushbuttons; external Start-Stop station required. Dimensions : page 05/ Schemes : page 05/ 0-EN_Ver.1.fm/

46 References Enclosed starters D.O.L. starters and equipment, with off-load isolator Equipment for control in utilisation category AC-1, (1), () Variants (pre-mounted) Description For Suffix to be use on added to reference () No pushbuttons on cover LE-D1 & D5 A0 1 blue Reset button R LE-D1 D80 A05 1 green Start button I and 1 red Stop LE-D1 & D5 A07 button O with 1 N/C contact (for distribution circuits without thermal overload relay) 1 neutral terminal (for -phase + N circuits) LE-D1 D80 A59 Accessories (mounted by the customer) Description For Reference Weight use on kg Start button latching device LE-D1 D65 LA9-D for stay put operation (Start-Stop) Kit to provide Stop function without LE-D1 & D5 LA9-D thermal overload relay fitted Miniature control LE-D1 & D5 LA9-D circuit fuse holder size 5 x 0, A/50 V Fuse supplied Pilot light with neon bulb, 110 V LE-D1 & D5 LA9-D red lens and locking ring 0 V LE-D1 & D5 LA9-D , 15 V LE-D1 & D5 LA9-D front-mounting block LE-D1 D80 L-DNpp 0.00 of auxiliary contacts Please consult your Regional Sales Office (1) -phase 0/0 V or 80/00 V 50/60 Hz. -core or + N (unprotected neutral) insulated PVC cable, fixed to walls, in cable racks or ducting, laid singly, ambient temperature 5 C, conforming to NF C () Order the required LR-D thermal overload relay separately. For use on balanced circuits only. () Example : LE-D16M7A0. Schemes : page 05/ Other versions Possible combinations of variants. Please consult your Regional Sales Office. 0-EN_Ver.1.fm/

47 Dimensions Enclosed starters D.O.L. starters and equipment, with off-load isolator LE-D16, D56 c c1 80 = = 1 = 60 = 1 LE- c c1 D D LE-D06, D656 = b H = c c1 (1) = G a = 1 (1) c1 = c for LE-Dppppp A0 (without pushbuttons). LE-D806 = a-75 = 1 Knock-outs or blanking plugs for cable glands Type of enclosure At At top bottom LE-D16 x 1 P x 1P b (1) b+57,5 b-50 b-75 = LE-D56 1 x 1 P and x 16 P 1 x 16 P LE-D06 1 x 1 P and 1 x 1 P and x 1 P 1 x 1 P LE-D656 1 x 1 P and 1 x 1 P and x 9 P 1 x 9 P LE-D806 1 x 1 P and 1 x 1 P and x 6 P 1 x 6 P xm8x5 = c c1 a-50 a a+57,5 (1) + 1 mm with blanking plugs. References : pages 0/ and 0/ Schemes : page 05/ 05-EN_Ver.11.fm/

48 Schemes Enclosed starters D.O.L. starters and equipment, with off-load isolator D.O.L. starters and equipment for control in category AC-1 LE-D16 and D806 LE-D16 and D56 LE-D06 and D656 LE-D806 LE-DpppppA0 LE-DpppppA0, DpppppA05 Q1 1/L1 /L 5/L U V W Q1/ 0 Q1 l N Q1/ O Q A Q1/ N Q1/6 l F1 O Q A Q1/ N Q1/1 F1 1 Q1 l O A Remote control 1 1 References : pages 0/ and 0/ Dimensions : page 05/ 05-EN_Ver.11.fm/

49 References Enclosed starters integral 18, and 6 contactor breakers and reversing contactor breakers for customer assembly Empty metal enclosures Type of For use Reference Weight enclosure on integral kg Degree of protection IP 5 LD1, LD or LD5-LB DE1-LT with drillings for door interlock mechanism (interlock not supplied), for customer assembly (1) LD1 or LD-LC DE1-LT LD5-LC DE1-LT5.710 LD1 or LD-LD DE1-LT Door interlock mechanisms (IP5) DE1-LT615 Type For use Colour Reference Weight on enclosure of knob kg Non-adjustable DE1-LT615 Red LA9-LB Black LA9-LB DE1-LT15 Red LA9-LC Black LA9-LC DE1-LT5 Red LA9-LC Black LA9-LC DE1-LT15 DE1-LT15 Red LA9-LC (LD1) Black LA9-LC DE1-LT15 Red LA9-LC (LD) Black LA9-LC Spare part Description For use Reference Weight on kg Kit for lockable For converting a black, LA9-LC knob on non-lockable control knob LD1-LC to a lockable knob Dimensions : pages 1175/ and 117_Ver.10-EN.fm/ (1) Enclosures supplied with drillings and removable blanking plugs for addition of cable glands (to be ordered separately): for number and diameter, see page 1175/. 1175/

50 References Enclosed starters integral 18, and 6 contactor breakers and reversing contactor breakers for customer assembly Empty insulated enclosures Type of For use Reference Weight enclosure on integral kg Degree of protection IP 0 LD1-LB DE1-LB with rectangular cut-out to suit fascia of the contactor breaker DE1-LC001 Degree of protection IP 5 LD1-LB DE1-LB with drillings for door interlock mechanism (interlock not supplied), for customer assembly Degree of protection IP 0 LD1 or LD-LC/0 DE1-LC with rectangular cut-out to suit fascia of the contactor breaker Dimensions : pages 1175/ and 1175/ 117_Ver.10-EN.fm/

51 Dimensions Enclosed starters integral 18, and 6 contactor breakers and reversing contactor breakers Enclosures Metal enclosures, IP5 degree of protection DE1-LT15, LT615 DE1-LT5, LT c ,75 = 195 = b DE1-LT15 DE1-LT5 = H = = = 181 = G a = Number of blanked-off cable entries for addition of cable glands At cable Ø For cable gland DE1- a b c G H DE1- top bottom min max N Type LT LT M LT M LT M M LT M M LT M M Insulated enclosures DE1-LB001 DE1-LB005 8,5 15 = = = = 109 DE1-LC001 = = = = References : pages 117/ and 117/ 1175_Ver.11-EN.fm/

52 Mounting of accessories Enclosed starters integral 18, and 6 contactor breakers and reversing contactor breakers integral 18 Non-adjustable door interlock mechanisms LA9-LB/ÃÃ For mounting on LD1-LB00 + LB/-LB0P// LD5-LB10 + LB/-LB0P// Door drillings (1) ,5 (1) = 19 = = = 5 = = (1) Thickness: 5 mm max. integral Non-adjustable door interlock mechanisms LA9-LC/ and LA9-LC5/ÃÃÃÃ For mounting on LD-LC/0 and LC/0, LD5-LC/0 LD-LC/0 LD-LC/0 LD5-LC/0 Door drillings (1) = = = 66 = = 8 = 5 85 = 85 = 99 1 (1) Thickness: 5 mm max. integral 6 Non-adjustable door interlock mechanisms LA9-LC/ and LA9-LC5/ For mounting on LD-LD/0 and LD5-LD/0 LD-LD/0 LD5-LD/0 Door drillings = = 5 = = 5 = = (LD) 17 (LD5) = 8 = = 90 = (1) Thickness: 5 mm max. References : pages 117/ and 117/ 1175_Ver.11-EN.fm/

53 Characteristics Enclosed starters integral and 6 contactor breakers and reversing contactor breakers Type integral integral 6 Number of poles and Rated operational current (Ie) A in AC- 6 in AC- Rated operational voltage (Ue) V Electrical durability, AC- at 15 V 1.5 million operating cycles 1. million operating cycles Mechanical durability at Uc 10 million operating cycles 5 million operating cycles Maximum operating rate " 600 operating cycles/hour 600 operating cycles/hour at ambient temperature 55 C $ With converter 600 operating cycles/hour 600 operating cycles/hour Environment Conforming to standards IEC : 97-1, 07-, 97-, 97--1, VDE : 0100, 0110, 011, 0170, 0171, 71, 0660 BS : 5, 75, 91 NEN, NBN Product certifications ASE, ASEFA, ASTA, BV, CSA, DEMKO, DNV, GL, NEMKO, NKK, ÖVE, RINA, SCC, SETI, UL, USSR, LROS, PTB, SEMKO LROS pending Protective treatment TH TH Ambient air temperature " Operation C around the device Storage C $ Operation C (1) With converter (1) Storage C Vibration resistance Hz Energised state : gn Energised state : gn Permissible acceleration De-energised state : gn De-energised state : gn Shock resistance Impulse duration : 11 ms Energised state : 8 gn Energised state : 8 gn Permissible acceleration De-energised state : 8 gn De-energised state : 8 gn Degree of protection To IEC 1 and 59 IP 0B IP 0B To VDE 0106 Protection against direct finger contact Protection against direct finger contact Flame resistance Conforming to IEC 95--1, NF C 0-55 and the requirement of (JO 7 NC of the 1st and //198), UL 9 - V0 and NF T Maximum operating altitude Without derating m Operating position In relation to From (without derating) normal vertical main axis mounting plane (left-right tilt) Control circuit characteristics From fixing plane (fore-aft tilt) From main axis (left-right tilt) Rated control " 50 Hz V circuit voltage (Uc) " 60 Hz V $ With converter V, 8, 110, 8, 110 Voltage limits Operating Uc Uc at θ 55 C Drop-out Uc Uc Average consumption " Inrush VA 160 (50 Hz), 185 (60 Hz) 75 (50 Hz), 50 (60 Hz) at 0 C and at Uc Sealed VA 1 (50 or 60 Hz) 5 (50 or 60 Hz) $ With Inrush W 50 duration 50 ms 00 duration 50 ms converter Sealed W 8 Heat dissipation " 50 Hz W (50 Hz), 5 (60 Hz) 8 (50 Hz), 11 (60 Hz) Operating time () " 50/60 Hz C ms at 0 C and at Uc O ms $ With C ms converter O ms () The closing time C is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time O is measured from the moment the coil supply is switched off to the moment the main poles separate. References : pages 1019/ to 1017/ 5 Dimensions : page 101/ Schemes : page 101/ 1015_Ver.11-EN.fm/

54 Characteristics Enclosed starters integral and 6 contactor breakers and reversing contactor breakers Type integral integral 6 Pole characteristics Rated thermal current (Ith) θ 0 C A 6 Frequency limits of operational current Hz Rated impulse withstand voltage (Uimp) Conforming to IEC 97- kv 8 8 Rated insulation voltage (Ui) Conforming to IEC 97-1 V Heat dissipation in the power Operational current A circuits of the contactor breaker and its protection module Power per pole, hot state W Rated making I rms Conforming to IEC 97- A 1 x Ith (1) 1 or 15 x Ith (1) capacity I peak Conforming to IEC 97- ka / 80/ 0 80/ 600/ 0/ 80/ 0 80/ 600/ Rated breaking capacity Operating voltage V Conforming to IEC 97- Value of cos ϕ Icu (O-t CO) ka rms () 0 5 () Ics (O-t-CO-t-CO) ka rms () Conforming to IEC Icu = Ics (O-t-CO-t-rCO) ka rms ensuring continuity of service O : breaking short-circuit current (open) ; t : time CO : closing on short-circuit, breaking short-circuit current (closed-open) (manual) rco : closing on short-circuit, breaking short-circuit current (remote control) Total breaking time ms Maximum let-through energy With Isc max. at 15 V, 50 Hz A s 100 x x 10 Cabling Maximum c.s.a. Minimum c.s.a. Maximum c.s.a Minimum c.s.a. Flexible cable without cable end mm 1 x 10 or x 6 1 x 1 1 x 50 or x 5 1 x 6 Flexible cable with cable end mm 1 x 6 or x 1 x 1 x 5 1 x 6 Solid cable mm 1 x 10 or x 6 1 x 1 1 x 50 1 x 6 Tightening torque N.m 6 Characteristics of thermal-magnetic or magnetic only protection modules LB1- LB6- LB1- LB1- LB1- LB6- LB1- Type LC0M LC0M LC//L LD0P LD0M LD0P LD0L Standard motors, frequent Standard Frequent Distrib. Standard Standard Frequent Distrib. Protection starting, distribution circuits motors starting circuits motors motors starting circuits Conforming to standards IEC 97- type (lq = 50 ka) and NF C Number of poles Number of protected poles Rated operational voltage V Maximum continuous current A Thermal protection Setting range (Irth min./irth max.) A 0.5/0.0 6./ / / /1... / / 5/6 5/6 5/6 Temperature compensation C Protection against phase imbalance With Without Without With With Without Without Tripping class Magnetic protection Instantaneous trip current Irth Fixed at conforming to IEC 97-1///6- setting range max. () 15 () Tripping tolerance ± 0 % Characteristics of versions with control test function, with padlocking facility Conforming to standards IEC 97, NF C 6-10, VDE 0660, VDE 011 Rated operational voltage V 690 Mechanical durability Operating cycles 10,000 Padlocking facility References : pages 1019/ to 1017/ 1, or padlocks (shank Ø 8 mm max. and Ø 5 mm min.). When flush mounting, interlocking of the enclosure or cabinet door is possible. (1) Above this value, the breaker trips. () Conforming to BS 75 : 6 ka cycle P, 50 ka cycle P1. () Cos ϕ 0.7. () Usual setting range 9 10 Irth max. 5 Dimensions : page 101/ Schemes : page 101/ 1015_Ver.11-EN.fm/

55 References Enclosed starters integral and 6 contactor breakers and reversing contactor breakers Enclosures Empty metal enclosures Type of For use Reference Weight enclosure on kg Degree of protection IP 5 (1) integral LD DE1-LT with drillings for door interlock mechanism (interlock not supplied). For customer assembly LD5 DE1-LT5.710 DE1-LT15 integral 6 LD DE1-LT (1) Enclosures supplied with drillings and removable blanking plugs for addition of cable glands (to be ordered separately): for number and diameter, see page 101/. Dimensions : page 101/ 1019_Ver.10-EN.fm/

56 References Enclosed starters integral and 6 contactor breakers and reversing contactor breakers Door interlock mechanisms Door interlock mechanisms (IP 5) Type For use on Colour Reference Weight enclosure of knob kg Non-adjustable DE1-LT15 Red LA9-LC DE1-LT5 Red LA9-LC or DE1-LT15 Dimensions : page 101/ 1019_Ver.10-EN.fm/

57 References Enclosed starters integral and 6 contactor breakers and reversing contactor breakers for the control and protection of motors -pole contactor breakers without protection module (1) Standard power ratings of -phase Opera- Breaking Basic reference. Weight motors 50/60 Hz in category AC- tional capacity Complete with current (Iq) code indicating for control circuit 0 V 00 V Ue 15 V voltage 0 V 15 V 0 V 500 V 660 V () kw kw kw kw kw A ka kg Without control test function, with padlocking facility Red knob on yellow background (CNOMO) Emergency Stop LD-LC00/ 1.50 LD-LC00/ LD-LD00/.800 -pole reversing contactor breakers without protection module (1) Without control test function, with padlocking facility Red knob on yellow background (CNOMO) Emergency Stop LD5-LC00/Ã() LD5-LD00/ () (1) For the unit to function, it must be fitted with a protection module, to be ordered separately. () Standard control circuit voltages (for other voltages, please consult your Regional Sales Office). Volts Hz LD/-LC, LD B D E F M M U Q N N S Y 60 Hz LD/-LC BC CC D FC FC MC MC/PU7 MC Q Q S LD/-LD BC CC CE K FC LC MC MC UX Q S LD5-LC00/ $ () LD/-LC, LD, BD ED FD () For use on d.c., the unit is supplied with 1 or converters, including coil suppression devices. ( converters for reversing contactor breakers. () It is essential to provide electrical locking for reversing contactor breakers integral. Dimensions : page 101/ Schemes : pages 101/ and 101/ 1017_Ver.11-EN.fm/

58 References Enclosed starters integral and 6 contactor breakers and reversing contactor breakers for the control and protection of motors (for customer assembly) Thermal-magnetic protection modules (compensated and differential for normal starting motors) LB1-LC0M Fixed magnetic protection, set at 15 Irth max, for mounting on integral 6 Standard power ratings of -phase Thermal Magnetic Reference Weight motors 50/60 Hz in category AC- setting setting range range 0 V 00 V V (Irth min 0 V 15 V 0 V 55 V 690 V to Irth max) kw kw kw kw kw A A kg LB1-LD0P LB1-LD0P LB1-LD0P LB1-LD0P LB1-LD0P LB1-LD0P LB1-LD0P Adjustable magnetic protection from 6 to 1 Irth max, for mounting on integral 0.06 ( ( ( ( LB1-LC0M ( ( ( ( ( LB1-LC0M ( LB1-LC0M ( LB1-LC0M LB1-LC0M LB1-LC0M LB1-LC0M LB1-LC0M LB1-LC0M LB1-LC0M LB1-LC0M Adjustable magnetic protection from 6 to 1 Irth max, for mounting on integral LB1-LD0M LB1-LD0M LB1-LD0M LB1-LD0M LB1-LD0M LB1-LD0M LB1-LD0M Magnetic only protection modules (for frequent starting motors) LB6-LC0M// Adjustable magnetic protection from 6 to 1 Irth max, for mounting on integral ( LB6-LC0M LB6-LC0M LB6-LC0M LB6-LC0M LB6-LC0M LB6-LC0M LB6-LC0M LB6-LC0M Adjustable magnetic protection from 6 to 1 Irth max, for mounting on integral LB6-LD0M LB6-LD0M LB6-LD0M LB6-LD0M LB6-LD0M LB6-LD0M LB6-LD0M ( There are no standard power ratings for these motors. Dimensions : page 101/ Schemes : pages 101/ and 101/ 1017_Ver.11-EN.fm/

59 References Enclosed starters integral and 6 contactor breakers and reversing contactor breakers for control and protection of resistive circuits in category AC-1 and -pole contactor breakers without protection module (1) Rated Maximum Maximum Breaking Number Basic reference. Weight thermal opera- operational capacity of Complete current tional voltage (Iq) poles with code Ith current for indicating θ 0 C AC-1 Ue 15 V control circuit θ 0 C voltage () A A V ka kg Without control test function, with padlocking facility Red knob on yellow background (CNOMO) Emergency Stop LD-LC00/ 1.50 LD-LC00/ LD-LD00/.800 Protection modules (for customer assembly) LD-LC00 Thermal-magnetic (compensated) Thermal Magnetic Number Number Reference Weight setting setting of of range range poles protected (Irth min (...6 Irth max) poles to Irth max) A A kg For integral LB1-LC0L LB1-LC0L LB1-LC05L LB1-LC0L LB1-LC0L LB1-LC05L LB1-LC0L 0.00 LB1-LC0L LB1-LC05L LB1-LC0L LB1-LC0L LB1-LC05L For integral LB1-LD0L LB1-LD0L LB1-LD0L// LB1-LD0L LB1-LD0L LB1-LD0L LB1-LD0L LB1-LD0L (1) For the unit to function, it must be fitted with a protection module, to be ordered separately. () Standard control circuit voltages (for other voltages, please consult your Regional Sales Office). Volts Hz LD/-LC, LD B D E F M M U Q N N S Y 60 Hz LD/-LC BC CC D FC FC MC MC MC Q Q S LD/-LD BC CC CE K FC LC MC MC UX Q S $ () LD/-LC, LD BD ED FD () For use on d.c., the unit is supplied with a converter, including coil suppression device. Dimensions : page 101/ Schemes : pages 101/ and 101/ 1017_Ver.11-EN.fm/

60 References Enclosed starters integral and 6 contactor breakers and reversing contactor breakers Auxiliary contact blocks and accessories Instantaneous auxiliary contact blocks (IP 0) For use Type and number Composition Reference Weight on of blocks per unit kg integral + L-LC00 LD or LD5 1 block of 6 instantaneous contacts L-LC Mounted on comprising: RH side signalling contacts contactor state 1 1 signalling contact tripped 1 on short-circuit 1 signalling contact tripped 1 1 signalling contact control knob 1 in any position other than Auto 1 block of 5 instantaneous contacts L-LC comprising: signalling contacts contactor state 1 1 signalling contact tripped 1 1 signalling contact tripped 1 on short-circuit Isolating blocks LD 1 control circuit isolating block 1 L-LC Mounted on (1 or blocks per unit) LH side integral + L-LC010 + L-LC070/ LD5 1 control circuit isolating block L-LC Mounted on LH side Electrical tripping devices For use Type and number Function Basic reference. Weight on per device Complete with code indicating control circuit voltage () LD or LD5 1 tripping block for operation Time delay L-LC070/ fitted with an on de-energisation 0. s L-LC010 (undervoltage trip) or Instantaneous L-LC07/ L-LC01 add-on block or 1 tripping block for operation Instantaneous L-LC071/ on energisation (shunt trip) Remote electrical reset devices For use Type and number Control Reference Weight on per device voltage kg LD or LD5 1 remote electrical V 50/60 Hz L-LC05B 0.0 fitted with an reset block L-LC010 or V 50 Hz L-LC05E 0.0 L-LC01 8 V 50/60 Hz add-on block 100/17 V L-LC05F /60 Hz 00/0V L-LC05M /60 Hz integral + L-LC01 + L-LC05/ () Standard control circuit voltages (for other voltages, please consult your Regional Sales Office) Volts /0 0 80/ Hz B E F M U Q N N 60 Hz B E F F M M Q N Dimensions : page 101/ Schemes : pages 101/ and 101/ 1017_Ver.11-EN.fm/5

61 Dimensions, schemes Enclosed starters integral and 6 contactor breakers and reversing contactor breakers Enclosures Dimensions Metal enclosures, degree of protection IP5 Insulated enclosure DE1-LT15 DE1-LT5, LT15 DE1-LC c b 105 = = a = 195 = = DE1-LT15 DE1-LT5 G a = = H = = = xø5,5 1 = 60 = DE1- a b c G H LT LT LT M LT M Non-adjustable door interlock mechanism LA9-LC5/ÃÃÃÃ integral integral 6 For mounting on LD-LC00 and LC00, LD5-LC00 For mounting on LD-LD00 and LD5-LD00 LD-LC00 LD-LC00 LD5-LC00 LD-LD00 LD5-LD00 thickness 5 mm max. Number of blanked-off cable entries At cable For cable gland DE1- top bottom min max N Type LT M M LT M M thickness 5 mm max Door drillings 15 = 19 = = 66 = = 8 = 5 85 = 85 = (LD) 17 (LD5) = 8 = = 90 = = = 5 = = 5 Schemes Contactor breakers with protection module LB/ integral integral 6 LD-LC0/0 + LB1-LC0// LB6-LC0M LD-LD00 + LB1-LD0/ LB6-D0M A N1 N 1/L1 /T1 /L /T 5/L 6/T /T1 /T 6/T Q1 A 1/L1 /T1 /L /T 6/T 5/L /T1 /T 6/T References : pages 1019/ to 1017/5 101_Ver.10-EN.fm/

62 Schemes Enclosed starters integral and 6 contactor breakers and reversing contactor breakers Reversing contactor breakers with protection module LB/ integral integral 6 LD5-LC00 + LB1-LC0M LD5-LD00 + LB1-LD0M or P /T1 /T 6/T /T1 /T 6/T /T1 /T 6/T /T1 /T 6/T A A A A 1/L1 /L 5/L 1/L1 /L 5/L LB6-LC0M LB6-LD0M Add-on blocks, integral and 6 For contactor breaker LD and reversing contactor breaker LD5 Mounted on RH side For contactor breaker LD Mounted on LH side Breaker L - LC010 L - LC01 L - LC00 L - LC05 L - LC001 L - LC00 Isolator Trip signalling Short-circuit signalling ou ou (6) (6) or L-LC00 Auto Control knob position signalling 15 For Reversing contactor breakers LD5 Tripping devices (1) Remote electrical reset devices (1) Mounted on LH side for LD, LD5 for LD, LD5 L-LC071 L-LC070, LC07 L-LC05/ L - LC01 Sectionnement Isolator C1 D1 TRIP + RESET Auto C D U< B B M B1 B References : pages 1017/ to 1017/ 5 Dimensions : (1) For contactor breakers and reversing contactor breakers already fitted with an L-LC010 or L-LC01 instantaneous auxiliary contact block. page 101/ 101_Ver.10-EN.fm/

63 References 0 Safety control and protection solutions Enclosed D.O.L. starters for motor control for use on a machine subject to the application of Machinery Directive 98/7/CE (1) Non reversing starters (with pushbutton control of isolation) Standard power ratings Circuit breaker Dust & damp protected starter Weight of -phase motors 50/60 Hz Setting range Basic reference. in category AC- of thermal trips Complete with code indicating 0/ 00/ control circuit 0 V 15 V 0 V voltage () () kw kw kw A kg LG7-K06// LG7-K06// LG7-K LG7-K06// LG7-K06// LG7-K06// LG7-K06// LG7-K06// LG7-K06// LG7-K09// LG7-D1// LG7-D18// Specifications LG7-D18// Functions performed by the starter: - isolation, - locking of isolation fitted as standard as from LG7-K09, - lockable Emergency Stop (1/ turn) (), - short-circuit protection, - overload protection, - pushbutton control: 1 white Start button I and 1 black Stop button O, - degree of protection of enclosure IP 657, double insulated Switching back on of power supply after tripping must be by a deliberate action. A GV-SN// indicator light may be added (to be assembled by customer), please consult your Regional Sales Office. For supply voltages between 80 and 15 V (codes Q7, V7 or N7) the control circuit is pre-wired between phases; for other supply voltages, the control circuit must be wired by the customer. LG7-D1 with padlocking facility fitted as standard Variants (pre-assembled) See page 06/5. (1) Compliance with a harmonised European standard assumes conformity with the corresponding directive, provided that installation, building in and/or assembly of the starter is carried out correctly by the machine manufacturer. Harmonised European standards: EN 6097 and EN 609. Conformity to international standards: IEC 97 and IEC 9. () Standard control circuit voltages (for other voltages, please consult your Regional Sales Office). LG7-K Volts " / 0 0/ 80/ 00 00/ / 50/60 Hz Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 LG7-D Volts " / / /60 Hz 0 00 Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 () LG7-K06: the mushroom head type Emergency Stop acts mechanically on the circuit breaker. LG7-K09, D1, D18: the Emergency Stop function is provided by an undervoltage coil, acting on the circuit breaker. This coil is always supplied pre-wired for use on 80/15 V 50 Hz. For a 60 Hz supply, please consult your Regional Sales Office. Dimensions : page 08/ 06-EN_Ver5.1.fm/ Schemes : page 08/ Other versions Starters for voltages other than those indicated above. Please consult your Regional Sales Office.

64 References (continued) 0 Safety control and protection solutions Enclosed D.O.L. starters for motor control for use on a machine subject to the application of Machinery Directive 98/7/CE (1) Non reversing starters (with rotary operator for control of isolation) Enclosure cannot be opened when energised in position I. Standard power ratings Circuit breaker Dust & damp protected starter Weight of -phase motors 50/60 Hz Setting range Basic reference. in category AC- of thermal trips Complete with code indicating 0/ 00/ control circuit 0 V 15 V voltages () kw kw kw A kg LG1-K065// LG1-K LG1-K065// LG1-K065// LG1-K065// LG1-K065// LG1-K065// LG1-K065// LG1-K065// LG1-K095// LG1-D1// LG1-D18// Specifications LG1-D18// Functions performed by the starter: - isolation, - locking of isolation, - lockable Emergency Stop (red/yellow switch disconnector), - short-circuit protection, - overload protection, - pushbutton control: 1 white Start button I and 1 black Stop button O, - degree of protection of enclosure: IP 657, double insulated, Switching back on of power supply after tripping must be by a deliberate action. A GV-SN// indicator light may be added (to be assembled by customer), please consult your Regional Sales Office. For supply voltages between 80 and 15 V (codes Q7, V7 or N7) the control circuit is pre-wired between phases; for other supply voltages, the control circuit must be wired by the customer. Variants (pre-assembled) See page 06/5. (1) Compliance with a harmonised European standard assumes conformity with the corresponding directive, provided that installation, building in and/or assembly of the starter is carried out correctly by the machine manufacturer. Harmonised European standards: EN 6097 and EN 609. Conformity to international standards: IEC 97 and IEC 9. () Standard control circuit voltages (for other voltages, please consult your Regional Sales Office). LG1-K Volts " / 0 0/ 80/ 00 00/ / 50/60 Hz Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 LG1-D Volts " / / /60 Hz 0 00 Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 Dimensions : page 08/ Other versions Schemes : page 08/ Starters for voltages other than those indicated above. Please consult your Regional Sales Office. 06-EN_Ver5.1.fm/

65 References (continued) 0 Safety control and protection solutions Enclosed D.O.L. starters for motor control for use on a machine subject to the application of Machinery Directive 98/7/CE (1) Reversing starters (with pushbutton control of isolation) Standard power ratings Circuit breaker Dust & damp protected starter Weight of -phase motors 50/60 Hz Setting range Basic reference. in category AC- of thermal trips Complete with code indicating 0/ 00/ control circuit 0 V 15 V 0 V voltage () kw kw kw A kg LG8-K06// LG8-K06// LG8-K LG8-K06// LG8-K06// LG8-K06// LG8-K06// LG8-K06// LG8-K06// LG8-K09//1 () LG8-K1//16 () 1.60 Specifications of reversing starters LG8-K09 with padlocking facility fitted as standard Functions performed by the starter: - isolation, - locking of isolation fitted as standard as from LG8-K09, - Emergency Stop (), - short-circuit protection, - overload protection, - control by selector switch 1-, position non maintained, - degree of protection of enclosure IP 657, double insulated. Switching back on of power supply after tripping must be by a deliberate action. A GV-SN// indicator light may be added (to be assembled by customer), please consult your Regional Sales Office. For supply voltages between 80 and 15 V (codes Q7, V7 or N7) the control circuit is pre-wired between phases; for other supply voltages, the control circuit must be wired by the customer. Variants (pre-assembled) See page 06/5. (1) Compliance with a harmonised European standard assumes conformity with the corresponding directive, provided that installation, building in and/or assembly of the starter is carried out correctly by the machine manufacturer. Harmonised European standards: EN 6097 and EN 609. Conformity to international standards: IEC 97 and IEC 9. () Standard control circuit voltages (for other voltages, please consult your Regional Sales Office). Volts " / 0 0/ 80/ 00 00/ / 50/60 Hz Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 () LG8-K06: The mushroom head type Emergency Stop acts mechanically on the circuit breaker. LG8-K09: the Emergency Stop function is provided by an undervoltage coil, acting on the circuit breaker. This coil is always supplied pre-wired for use on 80/15 V 50 Hz. For a 60 Hz supply, please consult your Regional Sales Office. Other versions Starters for voltages other than those indicated above. Starters for higher power ratings. Please consult your Regional Sales Office. Dimensions : page 08/ Schemes : page 08/ 06-EN_Ver5.1.fm/

66 References (continued) 0 Safety control and protection solutions Enclosed D.O.L. starters for motor control for use on a machine subject to the application of Machinery Directive 98/7/CE (1) Variants Description For use on Suffix to be added to starter reference () With Emergency Stop LG1, LG7, LG8 A0 No control pushbuttons With Emergency Stop LG8-K06 0 pushbuttons with arrows and (latching) 1 Stop button O Without Emergency Stop LG8 pushbuttons with arrows and (non latching) Without Stop button With Emergency Stop, LG1 A7 mushroom head Without Emergency Stop LG7, LG8 A9 (when the Emergency Stop is on the machine) With padlocking facility LG1-K06, LG7-K06 A9 (fitted as standard as from LG1-K09 or LG7-K09) 1 neutral terminal LG1, LG7, LG8 A59 Fitted as standard on starters ordered for use on 0 V (U7) supply Short-circuit LG7 signalling block Vacuum valve LG7-D A0 for compressor Without circuit breaker LG1, LG7, LG8 () Possible combinations of variants for the selected starter type () Starter type A0 0 A9 A7 A9 A0 A59 LG1-K (5) LG7-K06 LG7-K09 LG7-D1 LG8-K06 LG8-K09 Combination possible Combination not possible (1) Compliance with a harmonised European standard assumes conformity with the corresponding directive, provided that installation, building in and/or assembly of the starter is carried out correctly by the machine manufacturer. Harmonised European standards: EN 6097 and EN 609. Conformity to international standards: IEC 97 and IEC 9. () Example: LG7-D1M716A0. () Delete the last two digits of the selected starter reference. Example: LG1-K065//08 becomes LG1-K065// () Example: LG8-K095//A0A9A59. (5) LG1-K06: The mushroom head type Emergency Stop acts mechanically on the circuit breaker. LG1-K09, D1, D18: the Emergency Stop function is provided by an undervoltage coil, acting on the circuit breaker. This coil is always supplied pre-wired for use on 80/15 V 50 Hz. For a 60 Hz supply, please consult your Regional Sales Office. 06-EN_Ver5.1.fm/5

67 Dimensions 0 Safety control and protection solutions Enclosed D.O.L. starters for motor control for use on a machine subject to the application of Machinery Directive 98/7/CE Starters without isolator LG1-K06, K09 LG1-D1, D18 LG7-K06, K09, D1, D18 LG8-K06, K09, K1 10 (1) () () 177 (1) () Knock-outs or blanking plugs for cable glands (1) Emergency Stop for starters < kw Type of enclosure At At () Emergency Stop for starters kw top bottom () Only for LG7 LG1-K and LG1-D x 1 P and x 16 P x 1 P and x 16 P LG7-K and LG7-D x 1 P and x 16 P x 1 P and x 16 P LG8-K x 1 P and x 16 P x 1 P and x 16 P References : pages 06/ to 06/5 Schemes : page 08/ 08-EN_Ver.1.fm/

68 Schemes 0 Safety control and protection solutions Enclosed D.O.L. starters for motor control for use on a machine subject to the application of Machinery Directive 98/7/CE D.O.L. starters LG1-K06, K09, D1, D18 Q1 L L L1 LG1-K06, K09, D1, D18 80/00 V, code Q7 or 00/15 V, code N7 0/0 V, code M7 Ph T LG7-K06 LG7-K09, D1, D18 LG7-K06, K09, D1, D18 80/00 V, code Q7 or 00/15 V, code N7 0/0 V, code M7 1/L1 /L 5/L Q1 Reversing starters LG8-K06 LG8-K09, K1 LG8-K06, K09, K1 80/00 V, code Q7 or 00/15 V, code N7 0/0 V, code M7 1/L1 /L 5/L Q1 KM T T1 6 KM1/1 Q 1 S S 1 6 A U1 V1 W1 1 KM1/5 N Ph 1/L1 /L 5/L D1 D KM1/1 Q1 1 S1 1 F1 6 6 E1 E S U1 V1 6 W1 U1 Ph KM/5 S KM 6 6 S KM E1 E 1 6 A V1 W /L1 1 1 KM1/5 /L 5/L D1 N D 6 Q1 KM S U V W U V W KM KM/1 N A A References : pages 06/ to 06/5 Dimensions : page 08/ 08-EN_Ver.1.fm/

69 References 0 Safety control and protection solutions Enclosed D.O.L. starters for motor control for use on a machine subject to the application of Machinery Directive 98/7/CE Non reversing starters with integral transformer Compliance with a harmonised European standard assumes conformity with the corresponding directive, provided that the installation, building in and/or assembly of the starter is carried out correctly by the machine manufacturer. Harmonised European standards: EN 6097 and EN 609. Conformity to international standards: IEC 97 and IEC 9. LJ7-K Starters pre-wired for operation on a -phase 80 to 00 V 50 Hz supply (with pushbutton control of isolator function) Standard power ratings of Circuit breaker Starter: IP 657 Weight -phase motors 50 Hz Setting range Reference () in category AC- of thermal 80/ trips 00 V kw A kg LJ7-K06Q LJ7-K06Q LJ7-K06Q LJ7-K06Q ,6 LJ7-K06Q LJ7-K06Q LJ7-K06Q LJ7-K06Q LJ7-K09Q71.70 Specifications Functions performed by the starter: - isolation, - interlocking of isolator function fitted as standard on LJ7-K09, - lockable Emergency Stop (1/ turn) (1), - short-circuit protection, - overload protection, - pushbutton control: 1 white Start button I and 1 black Stop button O, - terminal allowing connection of a volt-free contact, if required, in the control circuit, - degree of protection of enclosure: IP 657, double insulated Reconnection of the power supply after a break must be by means of a deliberate action. A GV-SN// pilot light may be fitted; for customer assembly, please consult your Regional Sales Office. Integral transformer: 00/ V, 5 VA. Variants () Description For use on Suffix to be added to starter reference () With Emergency Stop function LJ7 A0 No pushbuttons Without Emergency Stop Function LJ7 A9 (when Emergency Stop is on the machine) With padlocking facility LJ7-K06 A9 (fitted as standard on LJ7-K09) Without circuit breaker LJ7 (5) (1) LJ7-K06 (P kw at 00 V): the mushroom head Emergency Stop button acts mechanically on the circuit breaker. LJ7-K09 (P > kw at 00 V): the Emergency Stop function is performed by an undervoltage trip GV-AX85, acting on the circuit breaker. The circuit breaker is automatically supplied pre-wired for use on a 80/00 V 50 Hz supply. () In the reference, the voltage code Q7 (80/00 V) indicates the power supply voltage to which the starter will be connected, it being assumed that the contactor has a " V coil (see control circuit scheme). () Possible combinations of variants A0, A9 and A9 on starters LJ7-K06. Example: LJ7-K06Q70A0A9A9. Possible combination of variants A0 and A9 on starters LJ7-K09Q71A0A9. () Example: LJ7-K06Q70A0. (5) Delete the last figures of the selected starter reference. Example: LJ7-K06Q70 becomes LJ7-K06Q7. Dimensions : page 605/ 60-EN_Ver..fm/ Schemes : page 605/ Other versions Starters for voltages other than those indicated above. Please consult your Regional Sales Office.

70 References (continued) 0 Safety control and protection solutions Enclosed D.O.L. starters for motor control for use on a machine subject to the application of Machinery Directive 98/7/CE Reversing starters with integral transformer Compliance with a harmonised European standard assumes conformity with the the corresponding directive, provided that the installation, building in and/or assembly of the starter is carried out correctly by the machine manufacturer. Harmonised European standards: EN 6097 and EN 609. Conformity to international standards: IEC 97 and IEC 9. LJ8-K Starters pre-wired for operation on a -phase 80 to 00 V 50 Hz supply (with pushbutton control of isolator function) Standard power ratings of Circuit breaker Starter: IP 657 Weight -phase motors 50 Hz Setting range Reference () in category AC- of thermal 80/ trips 00 V kw A kg LJ8-K06Q LJ8-K06Q LJ8-K06Q LJ8-K06Q ,6 LJ8-K06Q LJ8-K06Q LJ8-K06Q LJ8-K06Q LJ8-K09Q Specifications Functions performed by the starter: - isolation, - interlocking of isolator function fitted as standard on LJ8-K09, - lockable Emergency Stop (1/ turn) (1), - short-circuit protection, - overload protection, - pushbutton control: 1 white Start button I and 1 black Stop button O, - terminal allowing connection of a volt-free contact, if required, in the control circuit, - degree of protection of enclosure: IP 657, double insulated Reconnection of the power supply after a break must be by means of a deliberate action. A GV-SN// pilot light may be fitted; for customer assembly, please consult your Regional Sales Office. Integral transformer: 00/ V, 5 VA. Variants () Description For use on Suffix to be added to starter reference () With Emergency Stop function LJ8 A0 No pushbuttons Without Emergency Stop Function LJ8 A9 (when Emergency Stop is on the machine) With padlocking facility LJ8-K06 A9 (fitted as standard on LJ8-K09) Without circuit breaker LJ8 (5) (1) LJ8-K06 (P kw at 00 V): the mushroom head Emergency Stop button acts mechanically on the circuit breaker. LJ8-K09 (P > kw at 00 V): the Emergency Stop function is performed by an undervoltage trip GV-AX85, acting on the circuit breaker. The circuit breaker is automatically supplied pre-wired for use on a 80/00 V 50 Hz supply. () In the reference, the voltage code Q7 (80/00 V) indicates the power supply voltage to which the starter will be connected, it being assumed that the contactor has a " V coil (see control circuit scheme). () Possible combinations of variants A0, A9 and A9 on starters LJ8-K06. Example: LJ8-K06Q70A0A9A9. Possible combination of variants A0 and A9 on starters LJ8-K09. Example: LJ8-K09Q71A0A9. () Example: LJ8-K06Q70A0. (5) Delete the last figures of the selected starter reference. Example: LJ8-K06Q70 becomes LJ8-K06Q7. Other versions Starters for voltages other than those indicated above. Please consult your Regional Sales Office. Dimensions : page 605/ Schemes : page 605/ 60-EN_Ver..fm/

71 Dimensions 0 Safety control and protection solutions Enclosed D.O.L. starters for motor control for use on a machine subject to the application of Machinery Directive 98/7/CE LJ7-K06, LJ8-K LJ7-K09, LJ8-K Cut-outs or blanking plugs for cable glands at the top and at the bottom x 1 P and x 16 P. References : pages 60/ and 60/ 605-EN_Ver.11.fm/

72 Schemes 0 Safety control and protection solutions Enclosed D.O.L. starters for motor control for use in a machine subject to the application of Machinery Directive 98/7/CE Non reversing starters LJ7-K06 LJ7-K09 Q1 1/L1 /L 5/L 1 F1 A 1/L1 /L 5/L D1 D 1 F1 A U1 V1 1 W /5 /1 T1 00/ V 5 VA S X1 1 1 S Q1 U1 V1 1 W F1 E1 E /5 /1 T1 00/ V 5 VA S X1 1 1 S A M A Reversing starters LJ8-K06 1/L1 /L 5/L F1 S S KM 5 5 S 0 KM KM A A 1 Q KM/1 KM/5 T1 00/ V 5 VA KM F1 S1 11 S KM 5 5 S 0 KM KM A A U V W 6 6 LJ8-K09 1/L1 /L 5/L Q E1 KM KM/1 KM/5 T1 1 00/ V 5 VA U V 5 W 6 D1 6 D 6 E References : pages 60/ and 60/ 605-EN_Ver.11.fm/

73 Selection guide Enclosed starters Enclosed D.O.L. starters for AS-i bus Applications D.O.L. starters, reversing or non-reversing Constitution Thermal-magnetic circuit-breaker Contactor or contactor pair AS-i interface module LA9-Z811 Thermal-magnetic circuit-breaker Low consumption contactor or contactor pair Electronic control device Operator Rotary switch Degree of protection IP 55 Enclosure Insulated Sensor connection With With and local/bus control Without With With and local/bus control Starter type Reversing LF7-PppD LF7-PppDA79 LF1-PppD LF1- PppDA78 Non-reversing LF8-PppD LF8-PppDA79 LF-PppD LF- PppDA78 LF1- PppDA79 LF- PppDA79 Pages 088/ and 088/ 08/ and 08/ 059Q-EN_Ver.1.fm/

74 Selection guide (continued) Enclosed starters Enclosed D.O.L. starters for AS-i bus Pushbuttons IP 65 IP 55 Metal Insulated Metal With With and local/bus control Without With With and local/ bus control With With and local/bus control LF1-MPppD LF1-MPppDA79 LF1-MppD LF1- MppDA78 LF-MPppD LF-MPppDA79 LF-MppD LF- MppDA78 LF1- MppDA79 LF- MppDA79 LF1-MMppD LF-MMppD LF1-MMppDA79 LF-MMppDA79 059Q-EN_Ver.1.fm/

75 Presentation 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Presentation LF7 and LF8 starters These are the entry level models in our range of starters which communicate on the AS-Interface. These starters incorporate interface module LA9 Z811 and are subdivided according to the different power connection methods (cable gland or Harting plug-in connectors) and Local/AS-Interface remote operating modes. These economical devices provide a simple and effective solution for building decentralised motor starters as near as possible to the motor. LF1 and LF starters These complete, intelligent starters incorporate pre-programmed functions and a fault-management function. They are available in insulated or metal enclosures to suit different environments. When fitted with Harting plug-in connectors (variant A7), they drastically reduce setting-up times, thereby increasing the availability of machines. Decentralisation of machine starters These enclosed starters which communicate on AS-Interface are pre-assembled and ready-to-use with a minimum of cabling. They are designed for building decentralised electrical installations, i.e. the starters are installed as near as possible to the motors they are to control. The decentralisation of the starters provides obvious advantages regarding power distribution to machines not grouped together, for example: motors driving a conveyor system. Traditional installation Equipment floor-standing enclosure Distribution circuit circuit-breaker Programmable controller with its inputs/outputs Contactor + thermal overload relay Decentralised installation Power Distribution enclosure AS-Interface M M M M M Distribution circuit circuit-breaker Programmable controller AS-Interface starter Power is distributed either by prefabricated trunking or by cable. These starters incorporate all the functions necessary for the management of motors (control, protection, isolation, etc.), and comprise: - a thermal-magnetic circuit-breaker, - a low consumption contactor (non reversing) or contactor pair (reversing), - an electronic control device or, for LF7 and LF8, an AS-Interface module, LA9 Z811. Designed primarily for use with -phase a.c. motors, they can nevertheless be used with single-phase or d.c. motors. In these applications, the phases of the internal circuit-breaker should be wired in series (each phase sensing the same current) in order to avoid tripping due to an assumed phase failure. Characteristics : pages 090/ to 090/5 References : pages 08/ to 088/ Dimensions, schemes : pages 095/ to 095/9 Connections : pages 087/ and 087/ 091-EN_Ver.1.fm/

76 Description 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Connection by cable gland 1 Yellow LED, illuminated when motor running. Red LED illuminated when there is a motor fault (overload or short-circuit) or an internal fault in the starter, or in the event of a communication fault. Green LED illuminated (steady light) when the AS-Interface line is powered and flashing when information to the starter is being transmitted via the AS-Interface line. Knock-out for cable gland (included for auxiliary supply, power extension or output control relay cabling, if required). 5 Disconnect rotary control knob. Indicates Trip when switch-disconnector tripped. 6 Local/AS-Interface key switch (variant A79). 7 -position, spring return to zero selector switch for reversing starter (LF). Function: - position 1 = forward running, - position 0 = Stop, - position = reverse running (variant A79). Pushbutton for non-reversing starter (LF1). Function: Pulsed operation (variant A79). 8 Cable gland for power supply cable. 9 M1 female connector for cable connection to a sensor (supplied with protective cap) (variants A78 and A79). 10 M1 male connector for connection to AS-Interface (1) and auxiliary supply, if required. 11 Cable gland for motor cabling. 1 Reset pushbutton. 1 Stop pushbutton Connection by plug-in connectors (variant A7) 1 Yellow LED, illuminated when motor running. Red LED illuminated when there is a motor fault (overload or short-circuit) or an internal fault in the starter, or in the event of a communication fault. Green LED illuminated (steady light) when the AS-Interface line is powered and flashing when information to the starter is being transmitted via the AS-Interface line. Knock-out for cable gland (included) for auxiliary supply cabling, if required. 5 Male connector for incoming power supply to motor starter () 6 Disconnect rotary control knob. Indicates Trip when switch-disconnector tripped. 7 Female connector for power supply to the next motor starter () 8 Local/AS-Interface key switch (variant A79). 9 -position, spring return to zero selector switch for reversing starter (LF). Function: - position 1 = forward running, - position 0 = Stop, - position = reverse running (variant A79). Pushbutton: for non-reversing starters (LF1). Function: Pulsed operation (variant A79). 10 Female connector for power supply to motor (). 11 Knock-out for cable gland (included) for output control relay. 1 M1 female connector for cable connection to a sensor (supplied with protective cap) (variants A78 and A79). 1 M1 male connector for connection to AS-Interface (1) and auxiliary supply, if required. 1 Stop pushbutton. 15 Reset pushbutton (1) Extension cables: please consult your Regional Sales Office. () Harting plug-in connector to be fitted to cable (not included, see page 087/). Characteristics : pages 090/ to 090/5 References : pages 08/ to 088/ Dimensions, schemes : pages 095/ to 095/9 Connections : pages 087/ and 087/ 091-EN_Ver.1.fm/

77 Functions 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Auxiliary supply AS-Interface Control-command and contactor supply Control-command supply c V auxiliary supply Contactor supply Power supply LF1 and LF starters do not require an auxiliary supply to operate the contactors, since that provided by the AS-Interface line (yellow cable) is sufficient. Again, this reduces the cabling required. However, depending on the application, it is possible to supply the contactor coils by an external c V source. Selection is made by repositioning a jumper within the starter. A c V supply is necessary for LF7 and LF8 starters. Prospective current consumptions are listed on page 090/5. Motor command-control The functions provided by this range of starters are: - motor control and status monitoring via AS-Interface, - D.O.L. starting (non-reversing or reversing), - overload protection of the motor, - short-circuit protection of the motor and its power supply cabling. 117 Starters with rotary control knob These starters provide the following functions: - load break switch-disconnector with padlockable control knob, - IP 55 degree of protection, double insulation. Opening of the enclosure is mechanically inhibited whilst the starter is switched on or whilst in the off position and padlocked. The rotary control knob has positions: 0: switch-disconnector opened manually, I: switch-disconnector closed, Trip: switch-disconnector tripped. 119 Starters with pushbutton control These starters provide the following functions: - pushbutton resetting of the protection device, - pushbutton stop, - IP 65 degree of protection, double insulation. Characteristics : pages 090/ to 090/5 References : pages 08/ to 088/ Dimensions, schemes : pages 095/ to 095/9 Connections : pages 087/ and 087/ 091-EN_Ver.1.fm/

78 Functions (continued) 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Local control Stop and reset functions are possible from the front of the enclosure. The stop command is achieved by actuating the internal circuit-breaker, which provides the switch-disconnector function. Depending on the type of starter, stopping is controlled by either: - a rotary control knob, or - a stop pushbutton (black) (1). In the event of an overload, resetting of the internal thermal-magnetic circuit-breaker is possible after the motor has cooled down. Depending on the type of starter, resetting is controlled by either: - a rotary control knob, or - a reset pushbutton (blue) (1). 11 Integral local/as-interface control (variant A79) This starter variant is fitted with a -position local/as-interface switch which, depending on the position of the switch, allows the following functions: b AS-Interface: the PLC controls the motor starter. b Local: local Start/Stop commands override instructions from the PLC. b -position, spring return to zero selector switch for reversing starters (LF, LF8). Function: - position 1 = forward running, - position 0 = Stop, - position = reverse running. Pushbutton for non-reversing starters (LF1, LF7). Function: Pulsed operation. Control via a control station AS-Interface Message 1 Message Power supply It is possible to achieve manual local start control from a pushbutton control station connected to AS-Interface. Please consult your Regional Sales Office. Actuation of the pushbutton is transmitted to the programmable controller (message 1) which passes it on to the starter (message ). (1) Only a rotary control knob is available for starters LF7 and LF8. Characteristics : pages 090/ to 090/5 References : pages 08/ to 088/ Dimensions, schemes : pages 095/ to 095/9 Connections : pages 087/ and 087/ 091-EN_Ver.1.fm/5

79 Functions (continued) 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Local signalling Visual indication of the various operating states is provided by LEDs ( LEDs for LF1/LF and 1 LED for LF7/LF8) located on the enclosure cover. Safety The starter features continual self-checking to ensure correct operation. External safety functions are not processed by the starter. Emergency stop and machine safety wiring must follow standard safety practice and be hard-wired, using electromechanical devices in the approved way. These functions must not be handled by communication bus systems (EN ). Protection against sudden restarting, after an accidental power supply failure, must be provided by a safety device separate from the starter. The starter control (rotary knob or pushbutton) does not provide the Emergency Stop function if the machine is fitted with other actuators. The control operators on the starter are therefore coloured black, in accordance with standard EN Starters with rotary control knob may be padlocked in the ON position, since this control does not provide an Emergency Stop function. Loss of control (LF1, LF only) When communication is interrupted, the starter is no longer controlled by the PLC. In this case, it can be configured to adopt the following fallback conditions: - motor set to stop (applications: potentially dangerous movements), - motor set to run in direction 1 (forward) (applications: fans, pumps), - or motor continues to run as it was immediately prior to loss of control (application: suction grippers). The fallback configuration is set via AS-Interface. The default configuration is with the motor set to stop. Output control relay (LF1, LF only) This relay incorporates a C/O contact, which may be used to control an indicator lamp, solenoid valve, etc. ( V, 1 A), via AS-Interface. AS-Interface Characteristics : pages 090/ to 090/5 References : pages 08/ to 088/ Dimensions, schemes : pages 095/ to 095/9 Connections : pages 087/ and 087/ 091-EN_Ver.1.fm/6

80 Functions (continued) 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Starters with sensor connected Two -wire PNP sensors (50 ma max) or -wire limit switches can be connected directly to the starter. The information supplied by the sensor/limit switch is fed back via AS-Interface. In addition, for LF1 and LF starters only, the sensor signal can be processed locally to achieve a Reflex motor stop. This function is selected by means of micro switches. 17 other selections are reserved for future applications. Reflex stop (LF1, LF only) There are two types of Reflex stop function: b Reflex stop function n 1 Sensor n 1 directly controls stopping of the motor. After a new start instruction, the motor restarts (stop instruction then start instruction). A Reflex stop makes it possible to achieve precise and repetitive positioning, independently of the AS-Interface and PLC cycle times. For reversing starters, sensor n 1 acts on both running directions. Sensor n does not affect Reflex operation. Sensor Sensor 1 AS-Interface Rev Forw Time Instruction from AS-Interface Motor controlled by the starter Information from sensor 1 = component present b Reflex stop function n Sensor n 1 controls stopping of the motor when it is running in the forward direction. Sensor n controls stopping of the motor when it is running in reverse direction. A new start instruction (stop instruction then start instruction) causes restarting of the motor even if a component is still detected. Sensor n does not affect forward running. Sensor n 1 does not affect reverse running. Characteristics : pages 090/ to 090/5 References : pages 08/ to 088/ Dimensions, schemes : pages 095/ to 095/9 Connections : pages 087/ and 087/ 091-EN_Ver.1.fm/7

81 Characteristics 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Environment Starter type LF1, LF LF7, LF8 Conforming to standards IEC 600-1, EN 600-1, IEC 609-1, IEC , EN UL 508, CSA C- n 1 (1) Product certifications AS-Interface pending AS-Interface N Protective treatment Standard version TC TH Degree of protection conforming to IEC 6059 Ambient air temperature around the device conforming to IEC Starters with rotary control knob IP 55 IP 55 Starters with pushbutton control IP 65 Storage C Operation C Maximum operating altitude Without derating m 000 Operating positions without derating In relation to normal vertical mounting plane Flame resistance Conforming to IEC C 960 of equipment Shock resistance Contactor open 10 gn (1/ sine wave, 11 ms) conforming to IEC Contactor closed 15 gn Vibration resistance Contactor open gn Hz conforming to IEC Contactor closed gn Safe separation of circuits Conforming to VDE 0106 and IEC 6056 SELV (Safety Extra Low Voltage), up to 00 V Immunity to non-dissipating shockwave (Uimp) Material and colour of enclosure base Material and colour of enclosure cover Conforming to IEC kv 6: power.5: AS-Interface, V and sensor Insulated enclosures 6: power : AS-Interface, V and sensor Polycarbonate impregnated with 0 % glass fibre, black throughout Metal enclosures Sheet steel, RAL 70 Insulated enclosures Polycarbonate impregnated with 0% glass fibre, grey RAL 70 throughout Metal enclosures Sheet steel, RAL 70 Resistance to chemical agents Insulated enclosures Avoid allowing this material to come into contact with: strong bases (certain detergents), aromatic hydrocarbons, alcohol, chlorine solvents, ketones. Electromagnetic compatibility Immunity to electrostatic discharge Immunity to fast transient currents Immunity to dissipated shock wave Immunity to conducted radio-frequency disturbance Immunity to radiated radio-frequency disturbance Radio-conducted and radio-radiated rejection Conforming to IEC EN Conforming to IEC EN Conforming to IEC EN Conforming to IEC ENV Conforming to IEC ENV and ENV 50 0 (GSM) kv 8: in open air (level ) : in indirect mode (level ) kv : power, AS-Interface, V and sensor (level ) kv /: power (level ) /0.5: AS-Interface, V and sensor (level ) V/m 10 V/m 10 ENV /CISPR11 (G1) Class B Class A : AS-Interface, V and on inputs/outputs : AS-Interface, V and on inputs/outputs (1) Only for metal enclosures with letter U at the end of the reference. Functions : pages 091/ to 091/7 References : pages 08/ to 088/ Dimensions, schemes : pages 095/ to 095/9 Connections : pages 087/ and 087/ 090-EN_Ver6.1.fm/

82 Characteristics (continued) 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Connection Starter type LF1, LF7 LF, LF8 Min. Max. Min. Max. Power supply cabling Motor cabling Auxiliary V supply and output control relay cabling Screw clamp terminals Cable gland (Pg 16) Screw clamp terminals Cable gland (Pg 16) Solid cable mm 1x1.5 x6 1x1.5 x6 Flexible cable mm 1x1.5 x6 1x1.5 x6 without cable end Flexible cable mm 1x1.5 x 1x1.5 x with cable end Tightening torque (1) N.m Clamping capacity mm Min. Max. Min. Max. Solid cable mm 1x1.5 x 1x1.5 1x Flexible cable mm 1x1.5 x 1x1.5 1x without cable end Flexible cable mm 1x1.5 1x1.5+1x.5 1x1.5 1x.5 with cable end Tightening torque (1) N.m Clamping capacity mm Min. Max. Min. Max. Terminal block Solid cable mm Flexible cable mm without cable end Flexible cable mm with cable end Tightening torque () N.m Cable gland (included) Pole electrical characteristics Clamping capacity Pg 1 mm Pg 16 mm Utilisation category Conforming to IEC6097- A (circuit-breaker) Conforming to AC- (motor starter) Rated operational voltage (Ue) Conforming to IEC 6097 V 15 Rated insulation voltage (Ui) Conforming to IEC 6097 V 15 Rated operational frequency Conforming to IEC 6097 Hz 50/60 Breaking capacity (Ics and Icu) Sensitivity to phase failure Conforming to IEC Conforming to IEC /0 V ka >100 00/15 V ka > 100 Circuit-breaker characteristics (manual operation) Mechanical durability C.O.: closing, opening C.O Electrical durability In category AC- C.O Service class Maximum operating rate C.O./h 5 Circuit-breaker characteristics (automatic operation) Maximum operating rate In operating cycles 600 per hour Mechanical durability In millions of 0 5 operating cycles Electrical durability In category AC- to 8.5 A Yes Other characteristics Starters with rotary control knob Starters with pushbutton control Non-reversing starters Reversing starters Circuit-breaker type See our catalogue "Motor starter solutions" GV P Circuit-breaker type See our catalogue "Motor starter solutions" GV ME - LF1, LF only Contactor See our catalogue "Motor starter solutions" LP K09015BW Reversing contactor See our catalogue "Motor starter solutions" LP5 K09015BW (1) Philips n or flat screwdriver Ø 5.5. () Flat screwdriver Ø.5. Functions : pages 091/ to 091/7 References : pages 08/ to 088/ Dimensions, schemes : pages 095/ to 095/9 Connections : pages 087/ and 087/ 090-EN_Ver6.1.fm/

83 Characteristics (continued) 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Sensor inputs Starter type LF1, LF (A78 and A79) LF7, LF8 (A78) Connection M1 M1 Nominal input values Voltage V c c Maximum current ma 50 7 available per sensor Sensor supply (including ripple) V 19 0 Input value limits At state 1 Voltage V c >1.6 Current ma >.9 At state 0 Voltage V c <5 Current ma <.1 Input impedance kω > Filtering time Typical ms 7 Maximum ms 9.8 Maximum number of sensors Proximity sensor compatibility -wire/-wire -wire Isolation with respect to the AS-Interface line None Input type Resistive for PNP type sensor Output control relay (for starters LF1 and LF with variants A78 and A79) Operating voltage limit a.c. supply V d.c. supply V Thermal current at 0 C (Ith) A 5 Service life on an a V load Service life on a c V load Resistive load AC-1 Inductive load AC-1 Resistive load DC-1 Resistive load DC- Millions of operating cycles Millions of operating cycles Millions of operating cycles Millions of operating cycles Response time Latching ms <10 Unlatching ms <10 Contact type C/O 0.1 (1) in 5 A current, 1 () in 1 A current. 0.5 () in 1 A current, 1 () in 0.5 A current, 5 () in 0.5 A current. 0.1 (1) in 5 A current, 0. (1) in A current. 0.5 () in 1 A current, >1() in 0.5 A current. Built-in protection Isolation Against overloads None, a quick-blow fuse must be fitted and short-circuits Against a.c. or d.c. Protected against overvoltages generated by switching the coils of preactuators inductive overloads rms voltage between output V 1500, 50/60 Hz for 60 s and earth or between output and internal logic Insulation resistance between mω >1000 output terminals and AS-Interface (1) 0. of an operation (C/O) per second. () 0.5 of an operation (C/O) per second. () 1 operation (C/O) per second. Functions : pages 091/ to 091/7 References : pages 08/ to 088/ Dimensions, schemes : pages 095/ to 095/9 Connections : pages 087/ and 087/ 090-EN_Ver6.1.fm/

84 Characteristics (continued) 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Consumption Starter type Current consumption From the AS-Interface line Product configured for supply from the AS-Interface line Product configured for supply from an auxiliary c V supply LF1 LF LF1 LF LF7 LF8 De-energised 80 ma 90 ma 80 ma 90 ma 8mA 8mA Inrush 190 ma 00 ma 80 ma 90 ma Sealed 110 ma 10 ma 80 ma 90 ma 1 ma 1 ma With sensor Sensor consumption (50 ma max) + 15 ma (signal = 1) Relay 5 ma From the auxiliary c V supply De-energised Inrush 110 ma 110 ma 750 ma 750 ma Energised 0 ma 0 ma 750 ma 750 ma Data exchange characteristics AS-Interface profile 7.D () 7F Data bits (commands) Bit value = 0 = 1 For commands, please refer to the LF7 and LF8 starter schemes on page 095/6. Command D0 (O) Stop - forward running Start - forward running Command D1 (O) Command D (O) Stop - reverse running Start - reverse running () Deactivation of control relay Activation of control relay Command D (O) Not Used Not Used Data bits (status) Bit value = 0 = 1 For states, please refer to the LF7 and LF8 starter schemes on page 095/6. Status D0 (I) Not ready or fault Ready Status D1 (I) Stopped Running Status D (I) Status D (I) Sensor 1 signal absent (1) Sensor signal absent (1) Sensor 1 signal present (1) Sensor signal present (1) Parameter bits Bit value =0 =1(default value) Parameter P0 Maintain operational state Parameter P1 Fallback condition - Start Assume fallback condition Fallback condition - Stop Not used Not used Parameter P Not used Not used Not used Parameter P Reflex function inhibited Reflex function enabled Not used (1) Only applicable to starters with sensors (variants A78 and A79). () Only on LF or LF8. () Please consult the user s guide supplied with the product. Functions : pages 091/ to 091/7 References : pages 08/ to 088/ Dimensions, schemes : pages 095/ to 095/9 Connections : pages 087/ and 087/ 090-EN_Ver6.1.fm/5

85 Characteristics, references 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Models LF1 P and LF P Characteristics Conforming to standards IEC 600-1, 609-1, , EN 600-1, UL 508, CSA C- n 1 (1) Degree of protection Conforming to IEC 6059 IP 55 Ambient air temperature Operation -5to+0 C Operating positions Same as for the contactors Material LFp P: polycarbonate (). LFp MP: sheet steel 11 Starters in insulated enclosures LF1 PppD LF1 PppDA78 LF PppDA79A7 Standard power ratings of -phase motors 50/60 Hz in category AC- Circuit-breaker adjustment range of thermal trips Starter Reference Weight 0/0 V 00/15 V kw kw A kg Non-reversing starters with rotary control knob, with blue handle on black background () Without LF1 P00D () LF1 P0D LF1 P0D LF1 P0D LF1 P05D LF1 P06D LF1 P07D LF1 P08D LF1 P10D LF1 P1D LF1 P16D 1.50 Reversing starters with rotary control knob, with blue handle on black background () Without LF P00D () LF P0D LF P0D LF P0D LF P05D LF P06D LF P07D LF P08D LF P10D Starters in metal enclosures LF P1D LF P16D Add the letter M after LF1 or LF in the references selected above. Example: LF1 P0D becomes LF1 MP0D. To order a starter that conforms to standards UL 508 and CSA C- n 1, add a letter M after LF1 or LF and the letter U at the end of the references selected above. Example: LF1 P0D becomes LF1 MP0DU. Metal enclosures are fitted, as standard, with connections for sensors. 111 Variants (pre-assembled) LF MPppDA7A79 Description For mounting on Suffix to be added to the starter reference (5) With HARTING connectors (6) Insulated or metal enclosure A7 With connections for sensors Insulated enclosure A78 With connections for sensors Insulated enclosure A79 and local/as-interface control With local/as-interface control Metal enclosure A79 (1) Only for metal enclosures with letter U at the end of the reference. () Avoid allowing the material to come into contact with strong bases (detergents, chlorine solvents, ketones, alcohol, aromatic hydrocarbons). () On metal enclosures only, to order an Emergency Stop rotary control knob with red handle on yellow background, add the letter R to the end of the reference. Example: LF1 MP0DR. () Supplied without circuit-breaker GV P. (5) Example: LF1 P0DA79A7. (6) Connectors to be fitted to cables (to be ordered separately, see page 087/). Dimensions : pages 095/ to 095/5 Schemes : pages 095/7 and 095/9 08-EN_Ver10.1.fm/

86 Characteristics, references (continued) 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Models LF1 M and LF M Characteristics Conforming to standards IEC 600-1, 609-1, , EN 600-1, UL 508, CSA C- n 1 (1) Degree of protection Conforming to IEC 6059 Insulated enclosure IP 65 Metal enclosure IP 55 Ambient air temperature Operation -5to+0 C Operating positions Same as for the contactors Material LFp M: polycarbonate (). LFp MM: sheet steel Starters in insulated enclosures LF1 MppD LF1 MppDA78 LF1 MppDA79 Standard power ratings of -phase motors 50/60 Hz in category AC- Circuit-breaker Adjustment range of thermal trips Starter Reference Weight 0/0 V 00/15 V kw kw A kg Non-reversing starters with pushbutton control Without LF1 M00D () LF1 M0D LF1 M0D LF1 M0D LF1 M05D LF1 M06D LF1 M07D LF1 M08D LF1 M10D LF1 M1D LF1 M16D 1.00 Reversing starters with pushbutton control Without LF M00D () LF M0D LF M0D LF M0D LF M05D LF M06D LF M07D LF M08D LF M10D Starters in metal enclosures LF M1D LF M16D Add the letter M after LF1 or LF in the references selected above. Example: LF1 M0D becomes LF1 MM0D. To order a starter that conforms to standards UL 508 and CSA C- n 1, add a letter M after LF1 or LF and the letter U at the end of the references selected above. Example: LF1 M0D becomes LF1 MM0DU. Metal enclosures are fitted, as standard, with connections for sensors. 11 Variants (pre-assembled) LF MMppDA79A7 Description For mounting on Suffix to be added to the starter reference () With HARTING connectors (5) Insulated or metal enclosure A7 With connections for sensors Insulated enclosure A78 With connections for sensors and Insulated enclosure A79 local/as-interface control With local/as-interface control Metal enclosure A79 (1) Only for metal enclosures with letter U at the end of the reference. () Avoid allowing the material to come into contact with strong bases (detergents, chlorine solvents, ketones, alcohol, aromatic hydrocarbons). () Supplied without GV ME motor circuit-breaker. () Example: LF1 M0DA79A7. (5) Connectors to be fitted to cables (to be ordered separately, see page 087/). Dimensions : pages 095/ to 095/5 Schemes : pages 095/7 and 095/9 08-EN_Ver10.1.fm/

87 Characteristics, references (continued) 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Model LF7 P Characteristics Conforming to standards Degree of protection Conforming to IEC 6059 IP 55 Ambient air temperature Operation -10to+0 C Operating positions Same as for the contactors Material Polycarbonate (1) 1167 Starters in insulated enclosures Non-reversing starters with rotary control knob, with red handle on yellow background Standard power ratings of -phase motors 50/60 Hz in category AC- Circuit-breaker Adjustment range of thermal trips Starter Reference Weight 0/0 V 00/15 V kw kw A kg Without LF7 P00D () LF7 P0D LF7 P0D LF7 PppD LF7 P0D LF7 P05D LF7 P06D LF7 P07D LF7 P08D LF7 P10D 1.50 LF7 PppDA LF7 P1D LF7 P16D 1.50 Variants (pre-assembled) Description With HARTING connectors () Suffix to be added to the starter reference () A7 With local/as-interface control (5) A79 (1) Avoid allowing the material to come into contact with strong bases (detergents, chlorine solvents, ketones, alcohol, aromatic hydrocarbons). () Supplied without GV P motor circuit-breaker. () Example: LF1 P0DA79A7. () Connectors to be fitted to cables (to be ordered separately, see page 087/). (5) LF7 enclosures are fitted, as standard, with connections for sensors (-wire only). Dimensions : pages 095/ and 095/ Schemes : pages 095/6 to 095/9 088-EN_Ver7.1.fm/

88 Characteristics, references (continued) 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Model LF8 P Characteristics Conforming to standards Degree of protection Conforming to IEC 6059 IP 55 Ambient air temperature Operation -10to+0 C Operating positions Same as for the contactors Material Polycarbonate (1) 1167 Starters in insulated enclosures Reversing starters with rotary control knob, with red handle on yellow background Standard power ratings of -phase motors 50/60 Hz in category AC- Circuit-breaker Adjustment range of thermal trips Starter Reference Weight 0/0 V 00/15 V kw kw A kg Without LF8 P00D () LF8 P0D LF8 P0D LF8 PppDA LF8 P0D LF8 P05D LF8 P06D LF8 P07D LF8 P08D LF8 P10D LF PppDA78A LF8 P1D LF8 P16D Variants (pre-assembled) Description With HARTING connectors () Suffix to be added to the starter reference () A7 With connection for sensors (-wire only) A78 With local/as-interface control A79 (1) Avoid allowing the material to come into contact with strong bases (detergents, chlorine solvents, ketones, alcohol, aromatic hydrocarbons). () Supplied without GV P motor circuit-breaker. () Example: LF8 P0DA79A7. () Connectors to be fitted to cables (to be ordered separately, see page 087/). Dimensions : pages 095/ and 095/ Schemes : pages 095/6 to 095/9 088-EN_Ver7.1.fm/

89 References (continued) 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Insulated enclosures LF1, LF, LF7, LF8 Power extension (daisy-chaining) Terminal LA9 LFF LA9 LFF LA9 LFM LA9 LFM LA9 LFC LA9 LFT Metal enclosures LF1, LF LA9 LFM LA9 LFMM LA9 LFFM0 089-EN_Ver5.1.fm/

90 References (continued) 1 AS-Interface cabling system 1 Dedicated components Enclosed D.O.L. starters Accessories for insulated enclosures with variant A7 Presentation In order to reduce setting-up times and to simplify maintenance, variant A7 LF starters are fitted with Harting plug-in connectors. These starters are designed to allow types of connection topology. Connection using tap links LF LF This configuration avoids having to switch off the power supply when replacing or adding one or more starters. Although machine availability is increased, a larger number of power connections is required: per starter. Connection using power extension (daisychaining) The number of power connections per starter is halved, but continuity of service is no longer assured if any of the upstream starters are disconnected or removed. With this type of installation, special precautions must be taken because removal of a starter at the head of the power supply line de-energises all the remaining starters on that line. For safety reasons therefore, starters must not be removed under load (prohibited by standard EN600 above kw/00v). The connection kits and accessories shown below have been designed to facilitate setting up of power extension configurations by the user. Connection kit (depending on enclosure application) Enclosure application Power extension Terminal Capacity Kit contents For mounting on mm -pole 1.5 or.5 -pole 1.5 or.5 1 female connector male connectors and corresponding power sockets (1) 1 female connector 1 male connector, 1 blanking plug and corresponding power sockets (1) Reference Weight kg IP 55 enclosures LF1, LF, LF7, LF8 LA9 LFC IP 55 enclosures LF1, LF, LF7, LF8 LA9 LFT Crimping contacts Type Capacity mm Sold in lots of Unit reference Weight kg Male LA9 LFM LA9 LFM Female LA9 LFF LA9 LFF Accessories for metal enclosures with variant A7 Connection kit For connector Input Output to motor LF Kit contents LF For mounting on 1 metal cover Metal size 16 cable glands enclosures 1 blanking plug LF1, LF 1 female power socket (P + earth) female crimping contacts () 1 metal cover 1size16cablegland 1 female power socket (P + earth) (1) Crimping contacts Type Capacity Thermal current Voltage Metal enclosures LF1, LF Sold in lots of Reference Weight kg LA9 LFFM LA9 LFMM Unit reference Weight mm A V kg Male LA9 LFM LA9 LFM (1) Crimping contacts to be ordered separately. () For flexible cable, mm maximum, Ith: 16 A, Us: 00 V. 089-EN_Ver5.1.fm/

91 Dimensions AS-Interface cabling system Dedicated components D.O.L. starters in insulated enclosure Models LF1 P, LF P, LF7 P and LF8 P Non-reversing and reversing starters with rotary control knob With cable glands LFp PppD With HARTING plug-in connectors (A7) LFp PppDA x5, 8 10 x5, (1) (1) 18 With cable glands Incorporating sensor variant (A78) LFp PppDA78 With HARTING plug-in connectors (A7) Incorporating sensor variant (A78) LFp PppDA78A x5, 8 10 x5, (1) () (1) () 18 With cable glands Incorporating sensor and local/as-interface control variant (A79) LFp PppDA79 With HARTING plug-in connectors (A7) Incorporating sensor and local/as-interface control variant (A79) LFp PppDA79A x5, 8 10 x5, (1) () (1) () 18 Knock-outs for cable gland From above x Pg16 and x Pg1 From below 1 x Pg16 (1) M1 male connector for connection to AS-Interface () M1 female connector for connection to sensor. References : pages 08/ to 088/ Schemes : pages 095/6 to 095/9 095-EN_Ver.1.fm/

92 Dimensions (continued) AS-Interface cabling system Dedicated components D.O.L. starters in insulated enclosure Models LF1 M and LF M Non-reversing and reversing starters with pushbutton control With cable glands LFp MppD With HARTING plug-in connectors (A7) LFp MppDA x5, 8 10 x5, (1) (1) 18 With cable glands Incorporating sensor variant (A78) LFp MppDA78 With HARTING plug-in connectors (A7) Incorporating sensor variant (A78) LFp MppDA78A x5, 8 10 x5, (1) () (1) () 18 With cable glands Incorporating sensor and local/as-interface control variant (A79) LFp MppDA79 With HARTING plug-in connectors (A7) Incorporating sensor and local/as-interface control variant (A79) LFp MppDA79A x5, 8 10 x5, (1) () (1) () 18 Knock-outs for cable gland From above x Pg16 and x Pg1 From below 1 x Pg16 (1) M1 male connector for connection to AS-Interface () M1 female connector for connection to sensor. References : pages 08/ to 088/ Schemes : pages 095/6 to 095/9 095-EN_Ver.1.fm/

93 Dimensions (continued) AS-Interface cabling system Dedicated components D.O.L. starters in metal enclosure Models LF1 MP and LF MP Non-reversing and reversing starters with rotary control knob With cable glands LFp MPppD With HARTING plug-in connectors (A7) LFp MPppDA Ø ,5 15 Ø , Ø1 (1) Ø1 (1) With cable glands Incorporating sensor variant (A78) With HARTING plug-in connectors (A7) Incorporating sensor variant (A78) LFp MPppDA78 LFp MPppDA78A Ø7 8,5 Ø ,5 0 5 Ø1 (1) () Ø1 (1) () With cable glands Incorporating sensor and local/as-interface control variant (A79) LFp MPppDA79 With HARTING plug-in connectors (A7) Incorporating sensor and local/as-interface control variant (A79) LFp MPppDA79A Ø ,5 15 Ø , Ø1 (1) () Ø1 (1) () Knock-outs for cable gland Standard enclosure From above x Pg16 1 x Pg16 From below x Pg16 1 x Pg16 (1) M1 male connector for connection to AS-Interface () M1 female connector for connection to sensor. Enclosure with variant A7 References : pages 08/ and 08/ Schemes : pages 095/7 to 095/9 095-EN_Ver.1.fm/

94 Dimensions (continued) AS-Interface cabling system Dedicated components D.O.L. starters in metal enclosure Models LF1 MM and LF MM Non-reversing and reversing starters with pushbutton control With cable glands LFp MMppD With HARTING plug-in connectors (A7) LFp MMppDA Ø7 8,5 Ø , Ø1 (1) Ø1 (1) With cable glands Incorporating sensor variant (A78) With HARTING plug-in connectors (A7) Incorporating sensor variant (A78) LFp MMppDA78 LFp MMppDA78A Ø ,5 15 Ø , Ø1 (1) () Ø1 (1) () With cable glands Incorporating sensor and local/as-interface control variant (A79) LFp MMppDA79 With HARTING plug-in connectors (A7) Incorporating sensor and local/as-interface control variant (A79) LFp MMppDA79A Ø ,5 Ø ,5 0 5 Ø1 (1) () Ø1 (1) () Knock-outs for cable gland Standard enclosure From above x Pg16 1 x Pg16 From below x Pg16 1 x Pg16 (1) M1 male connector for connection to AS-Interface () M1 female connector for connection to sensor. Enclosure with variant A7 References : pages 08/ and 08/ Schemes : pages 095/7 to 095/9 095-EN_Ver.1.fm/5

95 Schemes AS-Interface cabling system Dedicated components Enclosed D.O.L. starters Models LF7 and LF8 Non-reversing starters LF7 LF7 1/L1 /L 5/L IN1 X, 1 IN X, IN X, LA9 Z811 (7F) IN X, IN + X, 5 M X, 6 OUT 1 X, 7 Q KM 1 Q Q KM A LF7 with variant A79 KM V 0 V V + IN1 X, 1 IN X, IN X, LA9 Z811 (7F) IN X, IN + X, 5 M X, 6 OUT 1 X, 7 + AS-i + AS-i /T1 U /T V 6/T W 5 1 V 0 V 0 1 Local line M 1 KM Q 1 1 Q KM A Reversing starters LF8 LF8 without variant and LF8 with variant A79 1/L1 /L 5/L V V 0 V + IN1 X, 1 IN X, IN X, LA9 Z811 (7F) Q KM LF8 with variant A78 U V W IN X, IN + X, 5 M X, 6 OUT 1 X, 7 OUT X, 8 + AS-i + AS-i 1 1 KM Q 1 1 V 0 V Local line II 0 I LF8withvariantA79 Q KM A A KM /T1 /T 6/T LA9 Z811 (7F) IN1 X, 1 IN X, IN X, IN X, IN + X, 5 M X, 6 OUT 1 X, 7 OUT X, 8 M 1 1 KM Q Q KM A A KM References : pages 088/ and 088/ Dimensions : pages 095/ and 095/ 095-EN_Ver.1.fm/6

96 Schemes (continued) AS-Interface cabling system Dedicated components Enclosed D.O.L. starters Models LF1 and LF Non-reversing starters LF1 1/L1 /L 5/L M1 AS-i AS-i AS-i + Q GV GV KM AS-i V ext. 0Vext. AS-i AS-i + V AS-i GV open GV tripped K1 auxiliary Local/line Local/AS-I I KM Signal sensor 1 Signal sensor Forward running GV KM /T1 /T 6/T Economy resistor U V M W 0 V AS-i Output control relay K NO COM NC AS-i V ext. M1 sensor Insulated enclosure with variant A78 + Insulated enclosure with variant A79 or metal enclosure with variant A79 Reversing starters LF 1/L1 /L 5/L M1 AS-i AS-i AS-i + V ext. AS-i AS-i + V AS-i GV open GV tripped KM1 GV GV KM1 KM AS-i Local/line 0Vext. KM Local/line Signal sensor 1 Signal sensor GV 1 0 Forward running KM Reverse running KM Economy resistor /T1 U /T V 6/T W 0 V AS-i Output control relay K AS-i V ext. NO COM NC M M1 sensor Insulated enclosure with variant A78 + Insulated enclosure with variant A79 or metal enclosure with variant A79 References : pages 08/ and 08/ Dimensions : pages 095/ to 095/5 095-EN_Ver.1.fm/7

97 Recommended application schemes AS-Interface cabling system Dedicated components Enclosed D.O.L. starters Models LF1, LF, LF7 and LF8 Non-reversing and reversing starters without sensor and without an auxiliary supply U V W U V W T1 T 6T 1L1 L 5L T1 T 6T 1L1 L 5L M M AS-Interface line Non-reversing and reversing starters with sensors, an auxiliary supply and a control relay U V W U V W T1 T 6T 1L1 L 5L T1 T 6T J5Ð J5+ 1L1 L 5L J NC J COM J NO M M AS-Interface line V References : pages 08/ to 088/ Dimensions : pages 095/ to 095/5 095-EN_Ver.1.fm/8

98 Recommended application schemes (continued) AS-Interface cabling system Dedicated components Enclosed D.O.L. starters Models LF1 and LF Connections on enclosures (LF1, LF only) M1 male connector for AS-Interface and c V auxiliary supply V AS-i AS-i V Sensor M1 female connector (for starters LF1 and LF, only applicable to starters with sensor variants A78 and A79) Limit switch -wire PNP type sensor -wire PNP type sensor 5 Sensor 1 1 Sensor Sensor 1 Sensor Sensor 1 Sensor References : pages 08/ to 088/ Dimensions : pages 095/ to 095/5 095-EN_Ver.1.fm/9

99 Connections AS-Interface cabling system Dedicated components Enclosed D.O.L. starters Starters in enclosures with cable glands 1 M Junction box Incoming power Power extension XZ LC10C1: splitter block 5 XZ CR151100Ap: extension 6 XZ CB1pp0: flat cable (black) for auxiliary supply 7 XZ CG010D: tap link for two cables 8 XZ CB1pp01: flat cable (yellow) for AS-Interface 9 XZ CG0105D: tap link for one cable Functions : pages 091/ to 091/7 Characteristics : pages 090/ to 090/5 References : pages 08/ and 088/ Dimensions, schemes : pages 095/ to 095/9 087-EN_Ver8.1.fm/

100 Connections (continued) AS-Interface cabling system Dedicated components Enclosed D.O.L. starters Starters in insulated enclosures with HARTING type plug-in power connectors M 1 1 Incoming power Power extension Control relay (example: illuminated indicator bank) XZ LC10C1: splitter block 5 XZ CR151100Ap: extension 6 XZ CB1pp0: flat cable (black) for auxiliary supply 7 XZ CG010D: tap link for two cables 8 XZ CB1pp01: flat cable (yellow) for AS-Interface 9 XZ CG0105D: tap link for one cable Configuration of HARTING connectors to be fitted on cables (to be ordered separately) Number and HARTING reference for incoming power female connector for power extension and motor connection male connectors Straight cover 1 x x Male insert 6-way, 00 V Female insert 6-way, 00 V x x Male contacts 8x mm Female contacts x mm Plug for the last socket 1x Starters in metal enclosures with HARTING type plug-in power connectors 1 1 Incoming power Control relay (example: illuminated indicator bank) XZ LC1C1: splitter block XZ CR151100Ap: extension 5 XZ CB1pp0p: flat cable (black) for auxiliary supply 6 XZ CG10D: tap link for two cables 7 XZ CB1pp01p: flat cable (yellow) for AS-Interface 8 XZ CG0105D: tap link for one cable M Configuration of HARTING connectors to be fitted on cables (to be ordered separately) Number and HARTING reference for incoming power female connector for power extension and motor connection male connectors Straight cover 1 x (1) 1x () x Male insert 6-way, 00 V x Female insert 1x way, 00 V Male contacts 5x mm Female contacts x mm (1) PG1. () PG9. Functions : pages 091/ to 091/7 Characteristics : pages 090/ to 090/5 References : pages 08/ to 088/ Dimensions, schemes : pages 095/ to 095/9 087-EN_Ver8.1.fm/

101 Presentation 1 AS-Interface cabling system 1 Dedicated components LA9 Z, AS-Interface V1 For D.O.L. starters Presentation AS-interface modules LA9 Z810 and LA9 Z811 allow motor starters to be monitored and controlled by AS-Interface. These products are in addition to the AS-Interface enclosed starter range, LF1 and LF, LF7 and LF8. The module sizes offered are: inputs/1 output or inputs/ outputs. These products can be mounted in two ways: b on 5 rail, b on LA9 Zppp adapters for use with busbar systems AS-I PWR AS-I PWR Inputs/outputs are connected to a built-in, flexible terminal type connector, so reducing installation time. The AS-Interface line is connected to the module by the yellow connector. The external c V supply to the module outputs is connected to the black connector. With this supply method, it is possible to make the output states subject to external safety conditions (Emergency stop, safety overtravel, etc.). Characteristics : page 58/ 58-EN_Ver.1.fm/ References : page 58/5 Dimensions, schemes : pages 58/6 and 58/7

102 Presentation (continued) 1 AS-Interface cabling system 1 Dedicated components LA9 Z, AS-Interface V1 For D.O.L. starters Fields of application The various module sizes allow control of: - non-reversing starters, - reversing starters, - -speed starters for motors with separate windings. The outputs, supplied by the separate auxiliary voltage, can simultaneously switch a current of 0.5 A at c V and can therefore switch the following contactors: - LP1, LP K06... K1, -LC1D09toD. Composition AS-I PWR 1 AS-Interface module 1 AS-Interface green/red LED indicator: - red: no communication with the Master. The outputs are switched off, - green: communication OK, outputs OK, - red/yellow flashing: module has no address (assign an address between 1 and 1), - off: no power supply to AS-Interface. Green PWR LED: - LED on: auxiliary power supply ON, - LED off: auxiliary power supply OFF. Characteristics : page 58/ References : page 58/5 Dimensions, schemes : pages 58/6 and 58/7 58-EN_Ver.1.fm/

103 Characteristics 1 AS-Interface cabling system 1 Dedicated components LA9 Z, AS-Interface V1 For D.O.L. starters General system environment Interface type LA9 Z810 LA9 Z811 Product certifications AS-Interface N AS-Interface N Protective treatment TH Degree of protection Conforming to IEC 6059 IP 0 Ambient air temperature around the device Storage, conforming to IEC 6059 C Operation C Maximum operating altitude Without derating m 000 Flame resistance Conforming to IEC C 960 Resistance to external mechanical impact Vibration resistance Immunity to non-dissipating shockwave (Uimp) Immunity to electrostatic discharge Immunity to fast transient currents Immunity to dissipated shock wave Immunity to conducted radio-frequency interference Immunity to radiated radio-frequency interference Radio-conducted and radio-radiated rejection 1/ sine wave, 11ms 15 gn conforming to IEC Hz gn conforming to Conforming to IEC kv.5: AS-Interface, V and on inputs/outputs Conforming to IEC EN Conforming to IEC EN level Conforming to IEC EN Conforming to IEC ENV Conforming to IEC ENV and ENV 50 0 (GSM) ENV /CISPR (G1) kv 8: in open air (level ) : in indirect mode (level ) kv : AS-Interface, V and on inputs/outputs kv V/m 10 V/m 10 : AS-Interface, V and on inputs/outputs Class A AS-Interface supply V Cabling c.s.a., AS-Interface Flexible cable mm x Cabling c.s.a., V Flexible cable mm x Cabling c.s.a., input/output Flexible cage terminal mm ; AWG8 1 and flexible cable Input current ma 7 Coincidence of inputs 100 % Maximum length of wires to switching components m 0. Maximum current of outputs c 1/1, ( V) A 0.5 Thermal current Ith A Coincidence of outputs 100 % Short-circuit protection By flywheel diode Yes Outputs switched off in event of interference on the AS-Interface line Watchdog Yes AS-Interface profile F 7F Number of I/O inputs/1 output inputs/ outputs Current consumption On AS-Interface On/OFF ma Data bits Status Command D0 (O) Out 1 Off On Off On D1 (O) Out Not used Off On D (O) Out Not used D (O) Out Not used Status D0 (I) In 1 Absent Present Absent Present D1 (I) In Absent Present Absent Present D (I) In Not used Absent Present D (I) In Not used Absent Present Parameters P0 P Not used Presentation : pages 58/ and 58/ 58-EN_Ver.1.fm/ References : page 58/5 Dimensions, schemes : pages 58/6 and 58/7

104 References 1 AS-Interface cabling system 1 Dedicated components LA9 Z, AS-Interface V1 For D.O.L. starters AS-Interface modules (1) () No. of Number channels of inputs Number of outputs Output voltage Current per output Reference Weight V A kg 1 c 0.5 LA9 Z c 0.5 LA9 Z Accessories Description Modules without electrical connection, for use with all LA9 Zpp adapters Busbar Width Reference Weight system mm mm kg 0 or 60 5 LA9 Z LA9 Z Module with PE + N polarity and 5-way connector 0 5 LA9 Z LA9 Z LA9 Z LA9 Z Replacement connectors and adapter cable Description Colour Sold in lots of Insulation Displacement Connector (IDC) for AS-Interface Unit reference Weight kg Yellow 5 LA9 Z Insulation Displacement Connector (IDC) for auxiliary supply Black 5 LA9 Z Description Cable length Reference Weight Adapter cable for connection to addressing terminal XZ MC11 m kg 0.5 XZ MG (1) User's Manual to be ordered separately, please consult your Regional Sales Office. () Supplied with connectors LA9 Z85 and LA9 Z86. Presentation : pages 58/ and 58/ Characteristics : page 58/ Dimensions, schemes : pages 58/6 and 58/7 58-EN_Ver.1.fm/5

105 Dimensions, mounting 1 AS-Interface cabling system 1 Dedicated components LA9 Z, AS-Interface V1 For D.O.L. starters Dimensions LA9 Z81p 86 5 Mounting on modules LA9 Z7, LA9 Z7 LA9 Z70, LA9 Z71 60 mm busbar system 0 mm busbar system Common front face view ,5 15,5 15,5 a 0 LA9 a Z70, Z7 5 Z71, Z7 5 LA9 Z75 0 or 60 mm busbar system LA9 Z7 Common front face view ,5 15,5 a LA9 a Z75 5 Z7 5 Presentation : pages 58/ and 58/ 58-EN_Ver.1.fm/6 Characteristics : page 58/ References : page 58/5

106 Schemes 1 AS-Interface cabling system 1 Dedicated components LA9 Z, AS-Interface V1 For D.O.L. starters D.O.L. starter, non-reversing 1 motor motors LA9 Z810 LA9 Z811 IN1 X, 1 IN X, IN + X, M X, OUT1 X, Q KM Q KM Q U V W /T1 /T 6/T 1/L1 /L 5/L Q1 KM U V W /T1 /T 6/T 1/L1 /L 5/L Q U V W /T1 /T 6/T 1/L1 /L 5/L IN1 X, 1 IN X, IN X, IN X, IN + X, 5 M X, 6 OUT1 X, 7 OUT X, 8 KM Q1 Q Q1 Q KM KM M M1 M D.O.L. starter, reversing LA9 Z811 IN1 X, 1 IN X, IN X, IN X, IN + X, 5 M X, 6 OUT1 X, 7 OUT X, 8 KM Q Q KM KM Q U V W /T1 /T 6/T 1/L1 /L 5/L KM M Presentation : pages 58/ and 58/ Characteristics : page 58/ References : page 58/5 58-EN_Ver.1.fm/7

Motor circuit-breakers

Motor circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years

More information

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) 4 NC1 D09-D18 NC1 -D32 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

Products and solutions for lifting systems

Products and solutions for lifting systems Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications

More information

Comparison of NEMA and IEC schematic diagrams

Comparison of NEMA and IEC schematic diagrams Cross-Reference MZ081001EN Comparison of NEMA and IEC schematic diagrams General With the increasing emphasis on globalization, many industries are now looking to all parts of the world to produce, market,

More information

Products and solutions for pumping, irrigation and piping

Products and solutions for pumping, irrigation and piping Products and solutions for pumping, irrigation and piping 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

Control Panel Technical Guide

Control Panel Technical Guide Control Panel Technical Guide How to select the appropriate motor starters for your HVAC & R* equipments * Heating, Ventilation, Air conditioning & Refrigeration Many machines can be used in a HVAC&R installation

More information

Power Generation. Power Control PCL System Generator Set Control

Power Generation. Power Control PCL System Generator Set Control Power Generation Power Control PCL System Generator Set Control Solid State Control The Power Control PCL system uses the latest solid state control technology. Designed for the budget-conscious installation

More information

Catalog January. Heavy industrial power applications Motor contactors and starters

Catalog January. Heavy industrial power applications Motor contactors and starters Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120 Circuit protection For i DPN (DPN), C60 and C120 Function They remotely trip or indicate circuit-breakers, with or without Vigi module. Description b They are mounted to the left of the circuit-breaker

More information

THERMAL RELAYS, MOTORSTARTERS

THERMAL RELAYS, MOTORSTARTERS THERMAL RELAYS, MOTORSTARTERS MH mini thermal relay plugged version H0K thermal relay with adapter H0K thermal relay plugged version T I thermal relay plugged version H thermal relay with current transformer

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5 Eaton Wiring Manual / Page Overview - ON-OFF switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-Speed Switches - Interlock

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Mureva Assembly surface mounted wiring devices

Mureva Assembly surface mounted wiring devices 1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label

More information

Products and solutions for machine builders (OEM) 100% electricity

Products and solutions for machine builders (OEM) 100% electricity Products and solutions for machine builders (OEM) 100% electricity www.lovatoelectric.com Tra dition and innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters

More information

Sentron Series Circuit Breakers

Sentron Series Circuit Breakers Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

Data Sheet. Electro-mechanical counters Hengstler 800 series

Data Sheet. Electro-mechanical counters Hengstler 800 series Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from

More information

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,

More information

Wiring diagrams. Compact NSX. Contents

Wiring diagrams. Compact NSX. Contents Compact NSX Wiring diagrams Contents Functions and characteristics A-1 nstallation recommendations B-1 Dimensions and connection C-1 Compact NSX100 to 630 Fixed circuit breakers D-2 Plug-in / withdrawable

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

Spare parts Catalogue

Spare parts Catalogue Technical catalogue Spare parts Catalogue Low voltage circuit-breakers Product support ABB SACE SDC0000D00 Not every original spare parts are really original spare parts. Availability of spare parts for

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

9 Control Equipment. Control Button Series 8082

9 Control Equipment. Control Button Series 8082 9 Control Equipment Control Button 01706E00 contact elements enable contact blocks to be combined easily; using an actuator in the 8602 series, regardless of the type of actuator, up to 4 contact elements

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

know-how Giant in distributing electricity for industry Prisma GK

know-how Giant in distributing electricity for industry Prisma GK Prisma GK Giant know-how in distributing electricity for industry Installation system up to 630A for electrical power distribution and circuit control. Prisma GK: technology and innovation for an IP55

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Notes on Product Changeover

Notes on Product Changeover 13 13/2 Notes on Product Changeover Introduction 13/3 Devices for delivery over the long term 13/4 devices with a mounting depth of 55 mm 13/5 devices with a mounting depth of 55 mm 13/15 devices with

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

SENTRON Switching and Protection Devices Air Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

General Informations 2 Technical data 3 Basic designs 4-8

General Informations 2 Technical data 3 Basic designs 4-8 Contents Page General Informations 2 Technical data 3 Basic designs 4-8 Cam Switches On-Off switches, Changeover switches 9-12 Star-Delta switches 13-15 Multi speed switches 16-20 Control switches 21-23

More information

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

VLT Series 3500 Adjustable Frequency Drive Instruction Manual Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

3K Load-Break Switches The Program for Safety and Performance. sentric

3K Load-Break Switches The Program for Safety and Performance. sentric 3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break

More information

How can a charging station for electric vehicles be set up simply and safely?

How can a charging station for electric vehicles be set up simply and safely? SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Safe switching and monitoring Solenoid Interlocks

Safe switching and monitoring Solenoid Interlocks Safe switching and monitoring Solenoid Interlocks Solenoid locking switches are used on sliding, hinged and removable guard doors that must be closed and locked for operator safety. It is a two part system

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

3RV Motor Starter Protectors up to 100 A

3RV Motor Starter Protectors up to 100 A General data Overview S0 motor 3RV1 motor are compact, current limiting motor which are optimized for load feeders. The motor are used for switching and protecting three-phase induction motors of up to

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

Reversing starter circuit for single phase induction motors Updated 1 st September 2008

Reversing starter circuit for single phase induction motors Updated 1 st September 2008 Reversing starter circuit for single phase induction motors Updated st September 008 Most single phase electric motors fitted to machine tools, compressors etc. are squirrel cage induction type which can

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

Industrial Automation Commonly-Used Terms

Industrial Automation Commonly-Used Terms Engineering Smarter Systems Industrial Automation Commonly-Used Terms A Glossary of Industrial Automation and Control Terms LECINC.COM 1 A Accelerating Time: Across the Line Starter: Action Device: Actuator:

More information

more than a breaker it s a breakthrough Compact NSX

more than a breaker it s a breakthrough Compact NSX Compact NSX, more than a breaker it s a breakthrough Compact NSX 100-630 A Intelligent outlook Today, we are living in an increasingly booming and fast changing world where energy is key. More than ever,

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation

More information

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases. G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable

More information

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST 12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest

More information

Telemecanique Zelio Relay complementary and easy to assemble

Telemecanique Zelio Relay complementary and easy to assemble Telemecanique Zelio Relay complementary and easy to assemble Get more with the world s Power & Control specialist RS interface relays Compact dimensions, enabling multiplication of contacts in electrical

More information

THE ADVANTAGES ARE YOURS

THE ADVANTAGES ARE YOURS THE ADVANTAGES ARE YOURS The new switches/discrepancy switches "R0-DR0" have special characteristics that make them very different from the normal switches on the market. Listed below are some of the many

More information