Experiment No. 4 STUDY AND APPLICATIONS OF TOOL MAKER S MICROSCOPE.
|
|
|
- Leona Carter
- 9 years ago
- Views:
Transcription
1 Tool maker s microscope Experiment No. 4 STUDY AND APPLICATIONS OF TOOL MAKER S MICROSCOPE. Aim :- Experiment on tool maker s microscope Apparatus :- Tool maker s microscope, specimen Theory :- Introduction:- The tool maker s microscope is a versatile instrument that measure by optical means with no pressure being involved, thus very useful for measurement on small and delicate parts. It is designed for: a) Measurement on parts of complex form e.g. - profile of external thread, tool, templates, gauges, etc. b) Measuring centre to centre distance of holes in any plane. c) A variety of linear measurements. d) Accurate angular measurements. e) fig. Tool Maker s Microscope -1-
2 Tool maker s microscope Tool maker s microscope is shown in fig. The optical head can be moved up or down the vertical column and can be clamped at any height by means of clamping screw. The table which is mounted on the base of the instrument can be moved in two mutually perpendicular horizontal directions (longitudinal and lateral) by means of accurate micrometer screw having thimble scale and venires. Principle of measurement: - fig. Principle of operation. A ray of light from a light source fig. b is reflected by a mirror through 90 It then passes through a transparent glass plate (on which flat parts may be placed ). A shadow image of the outline or counter of the workspaces passes through the objective of the optical head and is projected by a system of three prisms to a ground glass screen. Observations are made through an eyepiece. Measurements are made by means of cross lines engraved on the ground glass screen. The screen can be rotated through 360 ; the angle of rotation is read through an auxiliary eyepiece. -2-
3 Tool maker s microscope Procedure: - A) Pitch Measurement: - 1) Take the hacksaw blade and mount on the moving blade of tool maker s Microscope in horizontal position. 2) Focus the microscope on the blade. 3) Make the cross line in the microscope coincided with one of the edge of the blade. 4) Take a reading on ground glass screen, this is the initial reading. 5) The table is again moved until the next edge of the blade coincides with the cross-line on the screen and the final reading takes. 6) the difference between initial and final reading gives pitch of the blade. B) Teeth Angle :- 1) Place the blade on the table in same position. 2) Rotate the screen until a line on the angle of screen rotation is noted. 3) Take the angular reading, the initial one. 4) Again rotate the screen until the same line coincides with the other flank of the tooth. 5) Take the final angular reading. 6) The teeth angle of blade in the difference between the two angular readings. -3-
4 Tool maker s microscope Observation Table:- For Measurement Sr No. Initial reading Final reading Difference Mean 1 PITCH 2 3 TEETH ANGLE Result:- A) Pitch of blade = B) Teeth angle = -4-
5 Profile Projector Aim :- Experiment No. 4 STUDY AND APPLICATIONS OF PROFILE PROJECTOR Study and Applications of Profile Projector. Apparatus :- Profile Projector and Object Theory :- Introduction:- A profile projector is an optical measurement tool that magnifies a sample s surface features to allow measurement on a linear/circular scale. A profile projector is also referred to as an optical comparator, or even known as a shadowgraph. A profile projector projects a magnified profile image of an area or feature of a work piece onto a screen most commonly using diascopic illumination. Dimensions can be measured directly on the screen or compared to a standard reference at the correct magnification. For accuracy, it is important that the magnification does not change with perspective, i.e. its position or the view point of the operator. Telecentric lenses are, therefore, highly desirable. The screen often has a grid and this grid can often be rotated through 360 degrees to align with an edge as displayed on the screen. Point positions, measurements, and calculations may also be performed using a simple digital read out device. A computer may be added to a profile projector system for edge detection, thereby eliminating some human error. Applications:- -5-
6 Profile Projector Profile projectors are robust measuring tools commonly used in machine shops, quality assurance departments and occasionally on assembly shop floors. They are suitable for measuring and quality control for a wide range of size and weights of objects. The most basic use of a profile projector is to identify a point or edge on the shadow and from this point to calculate a length. By magnifying the image, the operator is less likely to make a mistake when deciding where the edge or point starts. Profile images can also be used to make simple stop / go decision by, for example, matching an image against a standard to determine whether a part has been made correctly. Preparing for work:- There are three basic requirements for perfect working of Profile Projector is A clean optical system Accurately centered lighting Careful focusing of the image All optical parts must be perfectly clean otherwise the projected image will appear dull without sharpness. Never touch the glass of episcopic lighting mirror with the fingers as they are extremely sensitive. -6-
7 Profile Projector 1. Centering the lighting The filament of lamp must be in the optical axis, i.e. must be set into the focus of the main condenser. The centering has to be done whenever the lamp is change. A badly centered light beam comes oblique to the optical axis and this gives rise to various problems. 2. Centering the Diascopic Lamp a. Draw the diagonals accurately with a pencil on a tranpaper. b. Remove the objective and condenser lens. c. Switch the regulator to half brilliance. d. Slacken clamp screw to enable the lamp socket to be moved in direction B-B and C-C. e. Slacken grub screw to enable the lamp socket to be moved in direction A-A. f. Move lamp socket in direction A-A / B-B and C-C until the image of the filament is sharp and central on the screen. The filament image must not be move than 2 to 3mm out of the center of the diagonals. g. Tighten the clamp screw and grub screw. h. Mount objective and condenser lens at its position. 3. Filters Filters can be fitted in the condenser mount by screwing the filter mount. In principle only white lisght is used for episcopic projection, in order to obtain maximum brightness. Green filters gives an image richer in contrast and allows uninterrupted working since the eyes become less tired with green light. 4. Surface Illumination (Episcopic Lighting) With episcopic projection, the light reflected from the object is thrown on to the screen. Light angles can be adjusted by tilting the mirror by unscrewing the knurled nut. With this appear not only the profile but also all the details of the surface such as engravings, machining marks, scratches and surface defects. Centering the Episcopic Lamp : a. Insert the 10x objective lens mount. b. Place a workpiece of white transpaper on the objective glass plate, draw a cross line on the paper. c. Switch on the diascopic lighting and adjust work table vertically by operating drive until the cross line of paper appears in the center of screen. d. Switch off Diascopic lamp again. e. Switch on Episcopic Lamp and adjust the light on mirrors f. Untighten the grub screw, move lamp socket until the filament appear on the middle of the longitudinal axis on the paper marked with cross line then tighten the grub screw. g. Slacken the knurled screw of lamp so that it can be moved in direction H-H, tighten the knurled screw. h. Setting up the surface illumination : -7-
8 Profile Projector Mount the required lens 10x, 20x, 25x Bring the proper height of light beam. Now place a transparent paper on the object table, switch on the diascopic light and adjust vertically till the image of the paper is sharp on the screen, then switch off the diascopic light. Switch on the episcopic light, will be noticed that half the light beam should be reflected by one mirror and half by other mirror. Moving mirrors centrally on one illuminated surface should bring reflected beam together again. Replace the piece of the paper with the object to be inspected and the clarity of certain details can sometimes be improved by the mirror. 5. Check the magnification with the transparent master scale, lay this scale on the objective glass table and measure its image on image screen by means of work scale. Observation Table:- SN Pitch Width (W) Depth (T) Average Result:- Calculate Teeth Angle using formula - Tan α = T/W 1. Pitch of the teeth for the given object = 2. Depth of the teeth for the given object = 3. Angle of the teeth for the given object = -8-
FirstView 3 Reflector Telescope Owner s Manual
FirstView 3 Reflector Telescope Owner s Manual 1. Horizontal Locking Auxiliary Screw 2. Main Mount 3. Pitching Auxiliary Knob 4. Pitching Shaft Screw 5. Rack and Pinion Focusing Knob 6. Thumb Nut for Finder
Profile Projector PH-3500
Optical Measuring Profile Projector PH-3500 Catalog No. E4155-172 Mitutoyo introduces the PH-3515F a series of profile projectors that will meet any optical measuring or inspection challenge your shop
WAVELENGTH OF LIGHT - DIFFRACTION GRATING
PURPOSE In this experiment we will use the diffraction grating and the spectrometer to measure wavelengths in the mercury spectrum. THEORY A diffraction grating is essentially a series of parallel equidistant
MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.
MICROSCOPY I. OBJECTIVES To demonstrate skill in the proper utilization of a light microscope. To demonstrate skill in the use of ocular and stage micrometers for measurements of cell size. To recognize
Care and Use of the Compound Microscope
Revised Fall 2011 Care and Use of the Compound Microscope Objectives After completing this lab students should be able to 1. properly clean and carry a compound and dissecting microscope. 2. focus a specimen
Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure
Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure The Microscope: A Tool of the Scientist You may refer to pages 66-67, 72-73 in your textbook for a general discussion of microscopes.
Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!
Instructions Manual Flexia BGA Inspection Systems This manual describes how to use Flexia BGA Inspection System Optilia Instruments 1 AB Contents 1. Safety and maintenance Instructions 3 2. About Flexia
Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012
Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012 Figure 1.1 illustrates the parts of an upright compound microscope and indicates the terminology that I use in these notes. Figure 1.1. Parts of a Compound
The Bonelle Tool and Cutter Grinder
The Bonelle Tool and Cutter Grinder The grinder was constructed about 1987 and exhibited at the 89th Model Engineering exhibition where it was awarded a bronze medal (see ME Vol164 No 3868 page 273). Subsequently
Measuring. User Manual
0 1 2 3 4 5 6 7 8 9 10 11 Measuring User Manual Accessories for measuring tasks Stage micrometer (1) for calibration Graticules with various measuring pitches (2) in mm and inches Graticule with mesh (3)
ENGINEERING METROLOGY
ENGINEERING METROLOGY ACADEMIC YEAR 92-93, SEMESTER ONE COORDINATE MEASURING MACHINES OPTICAL MEASUREMENT SYSTEMS; DEPARTMENT OF MECHANICAL ENGINEERING ISFAHAN UNIVERSITY OF TECHNOLOGY Coordinate Measuring
Experiment 3 Lenses and Images
Experiment 3 Lenses and Images Who shall teach thee, unless it be thine own eyes? Euripides (480?-406? BC) OBJECTIVES To examine the nature and location of images formed by es. THEORY Lenses are frequently
MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL
Introduction With your purchase of an MT-30/MT-90 series type microscope you have chosen for a quality product. The MT-30/MT-90 series type microscopes are developed for use at schools and laboratories.
TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions
TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 ENG Instructions Thank you for purchasing a Canon product. Canon s TS-E lenses are tilt-shift lenses designed for EOS cameras. The tilt-shift mechanism enables
Lenses and Apertures of A TEM
Instructor: Dr. C.Wang EMA 6518 Course Presentation Lenses and Apertures of A TEM Group Member: Anup Kr. Keshri Srikanth Korla Sushma Amruthaluri Venkata Pasumarthi Xudong Chen Outline Electron Optics
OPTICAL MEASURING MACHINES
OPTICAL MEASURIN MACHINES SYLVAC SCAN Dedicated to the fast and contactless measuring of cylindrical parts, our new SCAN machines are based on the principle of the scanner. This technique allows to reproduce
Chapter 17: Light and Image Formation
Chapter 17: Light and Image Formation 1. When light enters a medium with a higher index of refraction it is A. absorbed. B. bent away from the normal. C. bent towards from the normal. D. continues in the
CALIBRATION FOR LAL20X & LAL24X
CALIBRATION AND FAULT FINDING FOR LAL20X & LAL24X DUMPY LEVELS MEASURING EXPERTS SINCE 1869 How The LAL20X & LAL24X Works The Automatic level is called Automatic because it requires only a simple basic
OPERATING INSTRUCTIONS XJL 101/101A REFLECTED LIGHT METALLURGICAL MICROSCOPE
OPERATING INSTRUCTIONS XJL 0/0A REFLECTED LIGHT METALLURGICAL MICROSCOPE M.R.C.LTD. OFFICES: HAHYSTADRUT 84, HOLON 58394 P.O.B. 684, TEL-AVIV 606, ISRAEL TEL: 97-3-559305,97-3-55955 FAX: 97-3-559459 www.mrclab.com
Features: Mounting the Optic
MICRO GREEN DOT with INTEGRATED RED LASER The Patented Micro Green Dot with Integrated Red Laser is a compact optical system packed with many features. The Green Dot is designed as the primary targeting
GRID AND PRISM SPECTROMETERS
FYSA230/2 GRID AND PRISM SPECTROMETERS 1. Introduction Electromagnetic radiation (e.g. visible light) experiences reflection, refraction, interference and diffraction phenomena when entering and passing
EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab
EXPERIMENT O-6 Michelson Interferometer Abstract A Michelson interferometer, constructed by the student, is used to measure the wavelength of He-Ne laser light and the index of refraction of a flat transparent
Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments
Lecture 17. Image formation Ray tracing Calculation Lenses Convex Concave Mirrors Convex Concave Optical instruments Image formation Laws of refraction and reflection can be used to explain how lenses
Thin Lenses Drawing Ray Diagrams
Drawing Ray Diagrams Fig. 1a Fig. 1b In this activity we explore how light refracts as it passes through a thin lens. Eyeglasses have been in use since the 13 th century. In 1610 Galileo used two lenses
Basic Optics System OS-8515C
40 50 30 60 20 70 10 80 0 90 80 10 20 70 T 30 60 40 50 50 40 60 30 C 70 20 80 10 90 90 0 80 10 70 20 60 50 40 30 Instruction Manual with Experiment Guide and Teachers Notes 012-09900B Basic Optics System
M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual
M A R C O CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual CONTENTS GENERAL DESCRIPTION............... 1 INSTALLATION...................... 2 Mounting the Projector Positioning the Projector Positioning
THE COMPOUND MICROSCOPE
THE COMPOUND MICROSCOPE In microbiology, the microscope plays an important role in allowing us to see tiny objects that are normally invisible to the naked eye. It is essential for students to learn how
9/16 Optics 1 /11 GEOMETRIC OPTICS
9/6 Optics / GEOMETRIC OPTICS PURPOSE: To review the basics of geometric optics and to observe the function of some simple and compound optical devices. APPARATUS: Optical bench, lenses, mirror, target
Compound microscope (Hund)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 Compound microscope (Hund) 15 16 17 18 19 20 1) Eyepieces (magnifies 10x), one with diopter adjustment, 2) Interp[upillary adjustment, 3) Head, 4) Revolving nosepiece,
Geometric Optics Converging Lenses and Mirrors Physics Lab IV
Objective Geometric Optics Converging Lenses and Mirrors Physics Lab IV In this set of lab exercises, the basic properties geometric optics concerning converging lenses and mirrors will be explored. The
Light and its effects
Light and its effects Light and the speed of light Shadows Shadow films Pinhole camera (1) Pinhole camera (2) Reflection of light Image in a plane mirror An image in a plane mirror is: (i) the same size
HEADLIGHT BEAM SETTER USAGE GUIDE
RQHL03 HEADLIGHT BEAM SETTER USAGE GUIDE Fig.1 Assembling Fig.2 WORKING SURFACE Fig.4 OPTICAL POSITIONING Fig. 7 ANALOG LUXMETER GB INDEX OF CONTENTS GENERAL STANDARDS (SAFETY).....PAGE 6 DESCRIPTION
DO NOT OPERATE LANCELOT OR SQUIRE WITHOUT FIRST ADJUSTING THE SAFETY GUARD. ( See Below)
Assembly Instructions - Lancelot and Squire King Arthur s Tools (KAT) is pleased to present the first tandem mounted saw chain accessories whereby differing combinations of Lancelot and Squire may be paired
Lathe Milling Attachment
Lathe Milling Attachment By L C. MASON BY CLEVERLY stacking cold-rolled flat stock together, T-slots and slide for this lathe milling attachment are made without costly machinery. In fact, only two tools,
MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY
MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY Adapted from Foundations of Biology I; Lab 6 Introduction to Microscopy Dr. John Robertson, Westminster College Biology Department,
DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements
DMS 680 Universal length measuring system gauge inspection for»iso 9000«requirements Universal length measuring system DMS 680 Wide range of applications For periodic inspection of gauges, reference gauges,
SP AF 90mm F/2.8 Di Macro 1:1 (Model 272E)
SP AF 90mm F/2.8 Di Macro 1:1 (Model 272E) Thank you for purchasing this Tamron lens as the latest addition to your photographic equipment. Before using your new lens, please read the contents of this
P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)
INSURANCE SCAM OPTICS - LABORATORY INVESTIGATION P R E A M B L E The original form of the problem is an Experimental Group Research Project, undertaken by students organised into small groups working as
Laserlyte-Flex Alignment System
Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning
National Optical & Scientific Instrument Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instrument Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR STEREOSCOPIC MICROSCOPES MODEL NUMBERS 400 400TL
Fraunhofer Diffraction
Physics 334 Spring 1 Purpose Fraunhofer Diffraction The experiment will test the theory of Fraunhofer diffraction at a single slit by comparing a careful measurement of the angular dependence of intensity
A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31
A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31 Phase contrast Relief contrast Incorporation of advanced UIS2 optics ensures the highest level of clarity for cell checking applications.
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light Name: Period: Date: MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) Reflection,
To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.
STAGE MICROMETERS Introduction Whenever there is a need to make measurements with an eyepiece graticule, there is also a need to ensure that the microscope is calibrated. The use of a stage micrometer
Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide
Lunette 2 Series Curved Fixed Frame Projection Screen User s Guide Important Safety and Warning Precautions Please follow these instructions carefully to ensure proper maintenance and safety with your
Operator s Maintenance Manual STEINER BINOCULARS. Military ruggedness and precision 07/03
Operator s Maintenance Manual STEINER BINOCULARS Military ruggedness and precision 07/03 W arning! When using the binocular, never point it directly at the sun. The heat generated by the focused rays of
Traditional Drawing Tools
Engineering Drawing Traditional Drawing Tools DRAWING TOOLS DRAWING TOOLS 1. T-Square 2. Triangles DRAWING TOOLS HB for thick line 2H for thin line 3. Adhesive Tape 4. Pencils DRAWING TOOLS 5. Sandpaper
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODELS 106, 106-L 107, 107-L 108, 108-L 109-L ELEMENTARY
TEC APO140. This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy.
140 manuals 2013_110 manuals 1/13/2013 10:40 PM Page 1 TEC APO140 This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy. OWNER S MANUAL 2013 140
Understanding astigmatism Spring 2003
MAS450/854 Understanding astigmatism Spring 2003 March 9th 2003 Introduction Spherical lens with no astigmatism Crossed cylindrical lenses with astigmatism Horizontal focus Vertical focus Plane of sharpest
ACCESSORIES. Radiant Heater Controller, with 3021 Radiant Heater: Stand-Alone Radiant Heater Controller, with 3021 Radiant Heater.
ACCESSORIES Radiant Heater Controller, with 3021 Radiant Heater: Stand-Alone Radiant Heater Controller, with 3021 Radiant Heater. Assembly A-8984 K~1200D, Temperature Controller: A 400 watt microprocessorbased
Std. XI Science Physics Practical Handbook
Std. XI Science Physics Practical Handbook No. Experiments Page No. 1 Use of Vernier Callipers 1 2 Use of Micrometer screw gauge 5 3 Use of Spherometer 9 4 Parallelogram law of forces 12 5 Coefficient
Tube Control Measurement, Sorting Modular System for Glass Tube
Tube Control Measurement, Sorting Modular System for Glass Tube Tube Control is a modular designed system of settled instruments and modules. It comprises measuring instruments for the tube dimensions,
Fixturing systems Fixturing systems for measurement technology
Fixturing systems Fixturing systems for measurement technology Innovations and new additions to range Sets Spannfix Eco complete set The set contains different supports, extension elements and stop units.
Interference. Physics 102 Workshop #3. General Instructions
Interference Physics 102 Workshop #3 Name: Lab Partner(s): Instructor: Time of Workshop: General Instructions Workshop exercises are to be carried out in groups of three. One report per group is due by
Complete Dovetail Jig Instructions
Complete Dovetail Jig Instructions 18 15 1 12 13 8 (22818) 19 17 16 4 3 6 14 5 9 9 11 10 2 PARTS LIST - COMPLETE DOVETAIL JIG Introduction Your new dovetail jig will cut Full Through Dovetails and three
Electric Field Mapping Lab 3. Precautions
HB 09-25-07 Electric Field Mapping Lab 3 1 Electric Field Mapping Lab 3 Equipment mapping board, U-probe, resistive boards, templates, dc voltmeter (431B), 4 long leads, 16 V dc for wall strip Reading
PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24
PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24 V112712 1 Collimation and Secondary Spacing Procedure The CDK optical design has four optical elements shown in Figure 1. The primary mirror
Protocol for Microscope Calibration
Protocol for Microscope Calibration A properly calibrated system is essential for successful and efficient software use. The following are step by step instructions on how to calibrate the hardware using
AZEK Rail Install Guide
TRIM MOULDING DECK PORCH RAIL PAVERS AZEK Rail Install Guide Installing AZEK Rail with CableRail by Feeney... 1 Installing CableRail by Feeney for AZEK Rail... 7 Installing AZEK Rail Stairs with CableRail
Speed-Mat Rectangle Cutter
Speed-Mat Rectangle Cutter 1 Honeycomb baseboard. 2 Left hold down. 14 3 Bottom hold down. 4 4 Left / right rule. 8 5 8 5 Left / right rule pointer. 1 6 Top / bottom rule. 7 Top / bottom rule pointer.
INSTRUCTION. Industrial Sewing Machines. No. 010012. First published : June 1997 Second edition : March 2001
INSTRUCTION Industrial Sewing Machines First published : June 1997 Second edition : March 2001 No. 010012 INTRODUCTION Thank you for your purchasing Kansai Special's DLR Series. Read and study this instruction
MODEL T10023 ACCESSORY KIT #1 FOR T10010/T10097 WET GRINDER
MODEL T0023 ACCESSORY KIT # FOR T000/T0097 WET GRINDER INSTRUCTION SHEET Introduction The Model T0023 Accessory Kit # for the Model T000/T0097 Wet Grinder includes fixtures for sharpening small knives,
18-270mm F/3.5-6.3 Di II VC PZD for Canon, Nikon (Model B008) 18-270mm F/3.5-6.3 Di II PZD for Sony (Model B008)
R 18-270mm F/3.5-6.3 Di II VC PZD for Canon, Nikon (Model B008) 18-270mm F/3.5-6.3 Di II PZD for Sony (Model B008) Thank you for purchasing the Tamron lens as the latest addition to your photographic equipment.
First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between
Optical Differences Between Telescopes and Microscopes Robert R. Pavlis, Girard, Kansas USA icroscopes and telescopes are optical instruments that are designed to permit observation of objects and details
RETROFITTING THE X3 MILLING MACHINE (2)
RETROFITTING THE X3 MILLING MACHINE (2) Dick Stephen continues with the mechanical modifications. Fitting the ball screws The 12mm 2mm pitch supplied by THK ball screws are delivered with the nut fitted
TRIMMING UNIT/DIAMOND MACHINE TST.13
TRIMMING UNIT/DIAMOND MACHINE TST.13 REFERENCE BOOK rel. 02.15 TRIMMING UNIT/DIAMOND MACHINE TST.13 REL. 02.15 ENGLISH LANGUAGE 1 MACHINE DESCRIPTION TST.13 was designed and built for processing methacrylate.
The Vortex Spitfire 1x Prism Scope
REPLACE image The Vortex Spitfire 1x Prism Scope Perfect for the AR platform, the Vortex Spitfire 1x prism scope combines a compact, prism-based design with the intuitive, glass-etched DRT (Dual Ring Tactical)
Removing chips is a method for producing plastic threads of small diameters and high batches, which cause frequent failures of thread punches.
Plastic Threads Technical University of Gabrovo Yordanka Atanasova Threads in plastic products can be produced in three ways: a) by direct moulding with thread punch or die; b) by placing a threaded metal
IH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
Precision Measuring Tools. Participant Self-Paced Workbook
Precision Measuring Tools Participant Self-Paced Workbook Introduction Course Purpose The purpose of this course is to introduce you to precision measuring tools. In this course you will learn about decimals
1500 Follow Spot Yoke
= 1500 Follow Spot Yoke Rev 1.1 2004 City Theatrical, Inc. Getting Started with the City Theatrical Follow Spot Yoke Congratulations on the purchase of your City Theatrical Follow Spot Yoke. The City Theatrical
PROFESSIONAL REFRACTOR MODEL 78-0040 25
30 0 30 60 90 1 2 3 4 PROFESSIONAL REFRACTOR MODEL 78-0040 25 24 22 21 20 19 5 9060 18 6 7 17 16 15 8 14 13 9 11 12 10 Figure 1 1. Objective Lens 2. Mounting Screws (2) 3. Declination Axis 4. Equatorial
Resharpening Companion
Resharpening Companion 10950 Correct Angles, Pictures, and Step-By-Step Instructions The Resharpening Companion is meant to be a guide and quick reference to help you resharpen. It is not meant to replace
AF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17)
AF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17) Thank you for purchasing the Tamron lens as the latest addition to your photographic equipment. Di II lens (Digitally Integrated) series are designed for
Reflection and Refraction
Equipment Reflection and Refraction Acrylic block set, plane-concave-convex universal mirror, cork board, cork board stand, pins, flashlight, protractor, ruler, mirror worksheet, rectangular block worksheet,
THE BOHR QUANTUM MODEL
THE BOHR QUANTUM MODEL INTRODUCTION When light from a low-pressure gas is subject to an electric discharge, a discrete line spectrum is emitted. When light from such a low-pressure gas is examined with
Spring Term. Lecturer: Assoc. Prof. Dr. M. Zeki COŞKUN. Department of Geomatics Engineering e-mail : [email protected]
Spring Term Lecturer: Assoc. Prof. Dr. M. Zeki COŞKUN Department of Geomatics Engineering e-mail : [email protected] THEODOLITE What is Theodolite? Use of Theodoite Theodolite Terminology THEODOLITE Types
Alpy guiding User Guide. Olivier Thizy ([email protected]) François Cochard ([email protected])
Alpy guiding User Guide Olivier Thizy ([email protected]) François Cochard ([email protected]) DC0017A : april 2013 Alpy guiding module User Guide Olivier Thizy ([email protected])
35mm Twin-Lens Reflex Camera
How to assemble and use the supplement 5mm Twin- Reflex Camera Assembly time: Approx. one hour Assembled Product and Part Names Sports viewfinder hood Tripod socket Parts in the Kit Front Bottom Black
OD1641 PRINCIPLES OF DRAFTING AND SHOP DRAWINGS
SUBCOURSE OD1641 EDITION 8 PRINCIPLES OF DRAFTING AND SHOP DRAWINGS US ARMY REPAIR SHOP TECHNICIAN WARRANT OFFICER ADVANCED CORRESPONDENCE COURSE MOS/SKILL LEVEL: 441A PRINCIPLES OF DRAFTING AND SHOP
OPERATING P L AYA B I L I T Y P R E C I S I O N D E S I G N
P L AYA B I L I T Y P R E C I S I O N P E R F O R M A N C E OPERATING INSTRUCTIONS FOR: GolfWorks Loft and Lie Gauges code: HGCG/DGCG/LOLI2 4820 Jacksontown Road P.O. Box 3008 Newark, Ohio 43058-3008 Toll-Free:
10 TON HYDRAULIC PRESS
10 TON HYDRAULIC PRESS Model Nos. CSA10F and CSA10B OPERATING & MAINTENANCE INSTRUCTIONS 0200 SPARE PARTS and SERVICING Please contact your nearest dealer, or CLARKE International, on one of the following
MOVIEtube CR. Cinematography Rig. Setup Camera Sony PDW-F3 (MTCR-P-10-01) Version 03-2011 / English
MOVIEtube CR Cinematography Rig (MTCR-P-10-01) Setup Camera Sony PDW-F3 Version 03-2011 / English Step by step assembly instruction 1) The MOVIEtube CR (MTCR-P-10-01) is supplied as shown in the picture
39HQ Airovision Air Handling Units
39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport
PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES
British Made Portable Microscopes with Image Erection PCB Through - Hole Scope Depthscope Brinell Hardness Impression Microscope Cathode Ray Tube Inspector Portable Video Scope Metallurgical Microscope
Brief description and possible applications of the BAADER HYPERION EYEPIECES
Brief description and possible applications of the BAADER HYPERION EYEPIECES And the HYPERION ClickStop-Zoom Eyepiece # 245 4824 Clickstop Zoom 8-24 with complete range of adapters included in the basic
GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois 60076 U.S.A. tel: 1 847 673-5006 fax: 1 847 673-5009 email@gaertnerscientific.
7109-C-244E-R1 Field Installation of HeNe Laser in B, C, and D-Type Auto Gain Ellipsometers GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois 60076 U.S.A. tel: 1 847 673-5006 fax: 1 847
7.2. Focusing devices: Unit 7.2. context. Lenses and curved mirrors. Lenses. The language of optics
context 7.2 Unit 7.2 ocusing devices: Lenses and curved mirrors Light rays often need to be controlled and ed to produce s in optical instruments such as microscopes, cameras and binoculars, and to change
Original instructions Protective tube for Orion1B and Orion2 Orion WET-xxx and Orion WET-Kxxx
Original instructions Protective tube for Orion1B and Orion2 Orion WET-xxx and Orion WET-Kxxx While every effort has been taken to ensure the accuracy of information contained in this book and any associated
LIGHT SECTION 6-REFRACTION-BENDING LIGHT From Hands on Science by Linda Poore, 2003.
LIGHT SECTION 6-REFRACTION-BENDING LIGHT From Hands on Science by Linda Poore, 2003. STANDARDS: Students know an object is seen when light traveling from an object enters our eye. Students will differentiate
VICKERS HARDNESS TESTER. HBS HBW Kc
ICKERS HARDNESS TESTER H HK HBS HBW Kc Clean Touch Panel coordinated with highly integrated PC board. Measuring procedures, conditions and data are displayed clearly. (F-800 Series) Accurate light load
Endoscope Optics. Chapter 8. 8.1 Introduction
Chapter 8 Endoscope Optics Endoscopes are used to observe otherwise inaccessible areas within the human body either noninvasively or minimally invasively. Endoscopes have unparalleled ability to visualize
3. Loosen 3 x grub screws in the Dec end cap and unscrew the cap and counterweight shaft. NEQ6 Belt Modification Kit.
NEQ6 Belt Modification Kit. Thank you for your purchase. Please read these instructions fully before fitting. Your package should contain 2 off 47 & 2 off 12 tooth aluminium pulleys 2 off belts 6mm wide
RadianceRail Installation Guide
RadianceRail Installation Guide Installing RadianceRail with CableRail by Feeney... 2 Installing CableRail by Feeney for RadianceRail... 7 Installing RadianceRail Stairs with CableRail by Feeney... 10
DSV-2 ALTITUDE-AZIMUTH TELESCOPE MOUNT User Manual
DSV-2 ALTITUDE-AZIMUTH TELESCOPE MOUNT User Manual Your New Mount Thanks for choosing the Desert Sky Astro Products DSV-2 mount. Take some time to familiarize yourself with its features (Figure 1). Please
2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.
Physics for Scientists and Engineers, 4e (Giancoli) Chapter 33 Lenses and Optical Instruments 33.1 Conceptual Questions 1) State how to draw the three rays for finding the image position due to a thin
User Guide LUXXOR VIDEO MICROSCOPE. 2 Luxxor Video Microscope Set Up
2 Luxxor Video Microscope Set Up User Guide LUXXOR VIDEO MICROSCOPE Column When removed from its packaging, the Luxxor Video Microscope will be configured as shown, with the Vertical Slide and Slide Stop
View of ΣIGMA TM (Ref. 1)
Overview of the FESEM system 1. Electron optical column 2. Specimen chamber 3. EDS detector [Electron Dispersive Spectroscopy] 4. Monitors 5. BSD (Back scatter detector) 6. Personal Computer 7. ON/STANDBY/OFF
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104
National Optical & Scientific Instruments Inc. 11113 Landmark 35 Drive San Antonio, Texas 78233 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR MODELS 130, 131, 132, 138 & 139 COMPOUND MICROSCOPES