1 Worldwide Presence Engineering Expertise Leading Edge Technology Award Winning Support Our Commitment to Quality Signal Transformer Focus Catalog Your one source for wire wound magnetic solutions Linear Transformers Single Phase Three Phase Power EI & Toroidal Voltage Conversion Class 2 Industrial Control in NEMA Enclosures signaltransformer.com

2 PRODUCT INDEX Signal Transformer is your one source for wire wound magnetic solutions Product Series A41 Series Chassis Control Panel Super High Efficiency 4 Auto Transformer Series High Power International 5 CH Series 19 Toroidal (Power in the Round) 7 CL2 Series 13 & 25 More-4-Less Series All-4-One 10 DU Series 20 EB Series 17 All-4-One W/ Lead Wires 11 Class 2 13 HPI Series 5 ICT Series 21 IF Series V/120V Step Down 9 Multipurpose International 6 Two-4-One W/ Lead Wires 15 LP Series 28 Two-4-One 14 LPI Series 30 M4L Series 8 Machine Tool Transformer 12 Conventional Rectifier 16 MLP Series 28 Step Down Auto Transformer MPC Series 33 Filter & Dual Choke 19 MT Series 14 Power Isolation 20 MTT Series 12 PC Series 32 SHE Series 4 Industrial Control - NEMA 3 Enclosed 21 Three Phase 22 DIN Rail Mounting 23 SLT Series 9 ST Series 29 STP Series 7 Three Phase 22 PC Board Mount One-4-All International Class 2 25 Low Profile (Flat Head) 28 New Products All-4-One W/ Lead Wires 11 Encapsulated Low Profile Split Bobbin 29 Two-4-One W/ Lead Wires 15 Miniature Low Power 32 ICT Series 21 Miniature Low Power-Triple Output 33 MTT/DMTT Series 12 SHE Series 4 SLT Series 9 DIN Rail 23 Signal Transformer designs, manufactures and markets high quality Standard and Custom Magnetics for power conversion applications. Our advanced manufacturing facilities, worldwide presence and engineering expertise stand ready to assist you twith your next design need.

3 SHE Series Page 4 CL2 Series Page 13 CH Series Page 19 t utpu eo Tripl HPI & MPI Series Pages 5-6 MT Series Page 14 SU & DU Series Page L Series Page 15 3 Phase Series Page 22 STP Series Page 7 SLT Series Page 9 Rectifier Series Page 16 ICT Series Page 21 Lead A41 Series Page 10 Auto Trans Series Page 17 s Wire CHASSIS MOUNT A41-L Series Page 11 Small chassis mount transformers can easily be modified for Din Rail mounting. Application specific wire termination and connector interfacing is quick and easy. You can find the newest chassis mount products on the home page of our new optimized website.

4 SUPER HIGH EFFICIENCY SHE Series >97.5% Efficiency Power 250 VA to 2500 VA Dielectric Strength 4000 Vrms Hipot Input Dual / Tapped Windings Output Dual Windings Regulation 2.5% Maximum Efficiency >97.5 % or better Low Temperature Rise Meets UL, CSA, VDE and IEC Leakage <50 micro Amps Touch Safe Terminals (IP20 Type) E66312 SHE-250 (shown) The SHE series of Super High Efficiency transformers are specifically designed to reduce power operational costs, by utilizing optimal quality cores and conductor materials. The SHE transformers achieve superior ratings which address the overall trend to go green with cleaner, more efficient use of power. Part Number VA Secondary RMS Rating Mechanicals Size Series Parallel Lenght Width Height SHE A 2.2A 5.40 (137.2) 4.00 (101.6) 4.75 (120.7) Yes (5.33) SHE A 4.4A 5.40 (137.2) 5.00 (127.0) 4.75 (127.7) Yes (7.97) SHE A 6.6A 5.40 (137.2) 6.00 (152.4) 4.75 (120.7) Yes (10.26) SHE A 8.7A 7.70 (195.6) 5.50 (139.7) 6.63 (168.4) Yes (15.79) SHE A 13.0A 7.70 (195.6) 6.00 (152.4) 6.63 (168.4) Yes (18.82) SHE A 17.4A 7.70 (195.6) 6.50 (165.1) 6.63 (168.4) Yes (21.78) SHE A 21.8A 7.70 (195.6) 7.00 (177.8) 6.63 (168.4) Yes (25.65) Modification to standard parts and custom design available on request. Consult our customer service center to discuss your specific application. Electrical schematics, mechanical outlines and Data Sheets available on PRONTO 24-hour Shipment Pronto 24-Hour Shipment: Our PRONTO shipment program is simple. We ship off-the-shelf products within 24 hours and in most cases the same day! Signal maintains an extensive finished goods inventory that enables us to ship small volume orders from stock. We are able to make this commitment because we constantly replenish our inventory through a computerized MRP system that computes inventory/production schedules to match our customers requirements. Large production orders are conservatively scheduled to ensure meeting JIT or any delivery requirements, even those with tight lead times. In fact, each year over 20,000 orders are shipped to satisfied customers on time, every time. This chassis mounted high efficiency transformer can easily be modified.the SHE series is available in 7 different VA sizes. If your next design requires a high efficiency transformer we can help! Visit us at 4

5 HIGH POWER INTERNATINAL HPI Series VA Power 1250, 1500, 1750, 2000, 2750, 3500 VA ratings Dielectric Strength 4.0Kv Available Input Voltage 100V, 115V, 215V, 230V, 50/60Hz Output Voltage 115/230V Flammability Rating UL 94-V0 Constructed to meet UL Agency Certified UL, CSA, VDE and TUV Leakage <50 micro Amps Touch Safe Terminals (IP20 Type) HPI-12 (shown) The HPI series is constructed on a concentric platform, Signal s HPI series provides reinforced insulation while maintaining superior volumetric efficiency. Easily modified to your exact application. Available in 6 power ratings. Part Number VA Secondary RMS Rating Mechanicals Size Series Parallel Lenght Width Height HPI-12* V 10.9A 7.06 (179.3) 5.1 (129.6) 6.10 (154.9)) Yes 31.0 (14.07) HPI-15* A 13.0A 7.06 (179.3) 5.5 (139.7) 6.10 (154.9) Yes (16.23) HPI-17* V 15.2A 7.06 (179.3) 5.89 (149.7) 6.10 (154.9) Yes (17.50) HPI A 17.4A 7.50 (190.5) 5.26 (133.7) 6.56 (166.5) Yes 40.1 (18.16) HPI V 24.0A 7.50 (190.5) 5.89 (149.7) 6.56 (166.5) Yes 48.0 (21.77) HPI A 30.4A 7.50 (190.5) 6.99 (177.6) 6.56 (166.5) Yes 62.4 (28.30) Modification to standard parts and custom design available on request. Consult our customer service center to discuss your specific application. Electrical schematics, mechanical outlines and Data Sheets available on * All models have UL, CSA, TUV and VDE agency approvals except those marketed with * which have TUV instead of VDE. To learn more about our agency certification advantage visit our website Technical Support Technical Support: Signal s staff of application and design engineers is one of the largest in the industry. Their extensive knowledge of regulatory and safety agency requirements insures expeditious handling of complex certification issues. Using the latest SPICE and CAD/CAM software, the Signal team stands ready to respond quickly to your unique, design and application needs. Signal Transformer maintains an in-house ISO certified laboratory that enables us to participate in CSA s Shared Manufacturer Testing & Certification (SMTC) This program makes it possible to certify and use the CSA / ccsaus mark on new designs within days. Contact us for your next wire wound magnetic application we can help! signaltransformer.com 5

6 MULTI PURPOSE INTERNATIONAL MPI Series Greater Volumetric Efficiency Power 200 VA to 900 VA Dielectric Strength 4000 Vrms Hipot Dual Secondaries- Series or Parallel Electrostatic Shield Insulation Class F, 155 C Insulation Class F, 155 C Agency Certified UL, CSA and TUV Leakage <100 micro Amps Touch Safe Terminals (IP20 Type) MPI (shown) The MPI series transformers feature higher volumetric efficiency for improved performance compared with the conventional 50/60Hz transformers. They also incorporate international safety features making them ideal for worldwide applications. The MPI series can easily be modified to your specific application. Part Number VA Secondary RMS Rating Mechanicals Size Series Parallel Length Width Height MPI A 16.6A 3.75 (95.3) 4.46 (113.3) 3.66 (93.1) Yes 6.22 (2.82) MPI A 2.2A 4.12 (104.8) 4.13 (104.9) 3.86 (98.2) Yes 6.76 (3.07) MPI A 36.2A 4.12 (104.8) 4.45 (113.1) 3.86 (98.2) Yes 7.80 (3.54) MPI A 3.4A 4.12 (104.8) 5.04 (128.1) 3.86 (98.2) Yes 9.82 (4.46) MPI A 27.1A 5.25 (133.3) 4.70 (119.4) 4.63 (117.8) Yes (6.73) MPI A 150.0A 5.25 (133.3) 5.50 (139.7) 4.63 (117.8) Yes (9.01) Modification to standard parts and custom design available on request. Consult our customer service center to discuss your specific application. Electrical schematics, mechanical outlines and Data Sheets available on PRONTO 24-hour Shipment Pronto 24-Hour Shipment: Our PRONTO shipment program is simple. We ship off-the-shelf products within 24 hours and in most cases the same day! Signal maintains an extensive finished goods inventory that enables us to ship small volume orders from stock. We are able to make this commitment because we constantly replenish our inventory through a computerized MRP system that computes inventory/production schedules to match our customers requirements. Large production orders are conservatively scheduled to ensure meeting JIT or any delivery requirements, even those with tight lead times. In fact, each year over 20,000 orders are shipped to satisfied customers on time, every time. Electrical schematics, mechanical outlines and Data Sheets available on You can place your orders direct, with full confidence on our secure optimized website. To place an order simply use our unique part attribute search engine, find just the right part, click on the item enter the quantity and click checkout. Most product can be shipped next day. Contact us for your next wire wound magnetic application we can help! 6

7 TOROIDAL POWER STP Series Low Profile Power 100 VA to 2000 VA Dual Primaries 2 x 115V - 50/400 Hz Dual Secondaries Standard outputs 2 x 115V Diameter Ranging from 4.2 to 9.2 inches Low Profile Minimum Core Losses Reduced EMI / Low db UL Recognized to UL 506 / STP (shown) Signal routinely adds application specific terminations The STP series of toroidal transformers offer standard VA power ranges from 100 VA to 2000 VA inclusive. These standard toroidal transformers products share common lead lengths, colors and mounting configurations. The STP series are designed to comply with international safety standards. Available in 13 standard power ratings. Part Number VA Mechanicals Size Diameter Height Suggested Fastener Size STP (105) 1.4 (35) 2.86 (1.3) Yes #8 STP (127) 2.0 (50) 6.40 (2.9) Yes 1/4 STP (140) 2.9 (72) 12.1 (5.5) Yes 3/8 STP (155) 2.9 (72) 14.8 (6.7) Yes 3/8 STP (170) 2.9 (70) 22.1 (10.0) Yes 3/8 STP (180) 3.1 (78) 6.56 (166.5) Yes 3/8 STP (198) 3.2 (80) 29.5 (13.4) Yes 3/8 STP (210) 3.4 (86) 35.3 (16.0) Yes 1/2 STP (232) 3.6 (90) 44.1 (20.0) Yes 1/2 Modification to standard parts, higher VA rating and custom design available on request. Consult our application engineers to discuss your specific needs. Signal routinely adds application specific voltages, terminations and custom specific lead colors. Electrical schematics, mechanical outlines and data sheets available on Additional part numbers can be found on our website at For pricing, availability, electrical, mechanical, data sheets, information, shopping on-line or help with agency certification visit us at signaltransformer.com 7

8 MORE-4-LESS M4L Series Power 300, 450, 600 & 1000VA Dielectric Strength 4.0Kv Leakage Current - Agency <30 micro Amps Input Voltage 100V, 105V, 115V, 125V, 200V, 210V, 230V, 50/60Hz Output Voltage 115V Touch Safe Terminals Flame Rating UL 94-V0 Insulation Class F, 155 C Agency Certified UL, CSA, VDE Suitable for your UL product certification Greater Performance in Less Space M4L-1-3 (shown) Designed to provide superior isolation, the M4L series of transformers provide more than 12mm creepage distance between the input and output windings. The materials utilized in M4L construction supports high ambient temperature environments while minimizing energy losses. Part Number VA Secondary RMS Rating Mechanicals Size Voltage / Rated Amps Length Width Height M4L A 4.20 (106.68) 4.08 (103.51) 3.75 (95.3) Yes 7.0 (3.18) M4L (113.28) 4.33 (110) 4.50 (114.3) Yes 11.0 (5) M4L A 4.46(113.28) 5.08 (129.03) 4.50 (114.3) Yes 14.3 (6.49) M4L A 4.89 (124.20) 5.70 (144.78) 5.25 (133.4) Yes 22 Modification to standard parts and custom design available on request. Consult our application engineers to discuss your specific application Electrical schematics, mechanical outlines and data sheets available on PRONTO 24-hour Shipment Pronto 24-Hour Shipment: Our PRONTO shipment program is simple. We ship off-the-shelf products within 24 hours and in most cases the same day! Signal maintains an extensive finished goods inventory that enables us to ship small volume orders from stock. We are able to make this commitment because we constantly replenish our inventory through a computerized MRP system that computes inventory/production schedules to match our customers requirements. Large production orders are conservatively scheduled to ensure meeting JIT or any delivery requirements, even those with tight lead times. In fact, each year over 20,000 orders are shipped to satisfied customers on time, every time. Although we stock hundreds of standard products, there are specific applications that will always require that custom design. Signal Transformer is no stranger to customer specific designs, in fact for the past 50 years we have been doing just that, designing and manufacturing custom wire wound magnetic solution. Contact us for your next wire wound magnetic application we can help! 8

9 277V / 120V STEP DOWN TRANSFORMER SLT Series Power 300, 450, 600 & 1000VA Dielectric Strength 4000 Primary 277V, 60 Hz Secondary 120V with taps at 125V and 115V for high/low line adjustment Touch Safe Terminals Flame Rating UL 94-V0 Meets UL, CSA, VDE and IEC Insulation Class F, 155 C Greater Performance in Less Space E66312 SLT-300 (shown) Ideal for power task lighting and service receptacles. Available in 4 standard configurations and easily modified. Allows Installers to derive a Fully Isolated 120V Source from a 277V Line. Part Number VA Secondary RMS Rating Mechanicals Size Voltage / Rated Amps Length Width Height SLT A 4.20 (106.68) 4.08 (103.51) 3.75 (95.3) Yes 7.0 (3.18) SLT (113.28) 4.33 (110) 4.50 (114.3) Yes 11.0 (5) SLT A 4.46(113.28) 5.08 (129.03) 4.50 (114.3) Yes 14.3 (6.49) SLT A 4.89 (124.20) 5.70 (144.78) 5.25 (133.4) Yes 22.0 (10.0) Modification to standard parts and custom design available on request. Consult our application engineers to discuss your specific application Electrical schematics, mechanical outlines and data sheets available on PRONTO 24-hour Shipment Pronto 24-Hour Shipment: Our PRONTO shipment program is simple. We ship off-the-shelf products within 24 hours and in most cases the same day! Signal maintains an extensive finished goods inventory that enables us to ship small volume orders from stock. We are able to make this commitment because we constantly replenish our inventory through a computerized MRP system that computes inventory/production schedules to match our customers requirements. Large production orders are conservatively scheduled to ensure meeting JIT or any delivery requirements, even those with tight lead times. In fact, each year over 20,000 orders are shipped to satisfied customers on time, every time. Although we stock hundreds of standard products, there are specific applications that will always require that custom design. Signal Transformer is no stranger to customer specific designs, in fact for the past 50 years we have been doing just that, designing and manufacturing custom wire wound magnetic solution. Contact us for your next wire wound magnetic application we can help! signaltransformer.com 9

10 ALL-4-ONE INTERNATIONAL A41 SERIES A41 Series - Dual & Triple Output Power 25 VA to 175 VA Dielectric Strength 4000 Vrms Hipot Secondaries Series, Parallel and Triple Leakage Current Meets UL Terminals Solder Lugs or Quick Connects Available with IEC / DIN compliant Quick Connects and Snap-On protective cover Int l Standards at a Low Cost Flammability Rating UL 94-V0 Insulation Class F, 155 C Agency Certified UL, CSA, VDE Dual & Triple Output A & A (shown) The A41- Dual and Triple output series are designed to provide the high isolation, creepage and clearance necessary to comply with international safety standards such as IEC 61558, IEC 60601, IEC and more Part Number VA Secondary RMS Rating Mechanicals Size Series Parallel Length Width Height A A 2.81 (71.4) 2.14 (54.4) 2.31 (58.7) Yes 1.25 (0.57) A A 2.81 (71.4) 2.14 (54.4) 2.31 (58.7) Yes 1.25 (0.57) A A 3.6A 3.12 (79.4) 2.14 (54.4) 2.68 (68.2) Yes 1.6 (0.73) A A 3.12 (79.4) 2.14 (54.4) 2.68 (68.2 Yes 1.6 (0.73) A A 6.6A 2.50 (63.5) 2.52 (64.3) 3.00 (76.2) Yes 2.8 (1.27) A A 10.8A 2.81 (71.4) 3.00 (76.2) 3.37 (85.7) Yes 4.1 (1.86) A A 12.5A 3.12 (79.4) 3.14 (79.7) 3.75 (95.3) Yes 5.5 (2.49) Modification to standard parts and custom design available on request. Consult our application engineers for solutions to your specific application. Electrical schematics, mechanical outlines and data sheets available on Triple Output Part Number VA Secondary RMS Rating Mechanicals Size Regulator 1 Regulator 2 Length Width Height A A 150mA 2.81 (71.4) 2.14 (54.4) 2.31 (58.7) Yes 1.25 (0.57) A A 250mA 3.12 (79.4) 2.14 (54.4) 2.68 (68.2) Yes 1.6 (0.73) A A 500mA 2.50 (63.5) 2.53 (64.3) 3.00 (76.2) Yes 2.8 (1.27) Additional part numbers can be found on our website at Signal Transformer maintains an in-house ISO certified laboratory that enables us to participate in CSA s Shared Manufacturer Testing & Certification (SMTC) This program makes it possible to certify and use the CSA / ccsaus mark on new designs within days. Contact us for your next wire wound magnetic application we can help! 10

11 ALL-4-ONE INTERNATIONAL WITH LEAD WIRES A41-L Series Power 25 VA to 175 VA Dielectric Strength 4000 Vrms Hipot Dual Secondaries Series or Parallel Leakage Current Meets UL Int l Standards at a Low Cost Flammability Rating UL 94-V0 Insulation Class F, 155 C Agency Certified UL, CSA, VDE A L (shown) The A41 series are designed to provide the high isolation, creepage and clearance necessary to comply with international safety standards. The A41 series is available with over 40 standard configurations. Part Number VA Secondary RMS Rating Mechanicals Size Series Parallel Length Width Height A L A 2.0A 2.81 (71.4) 2.14 (54.4) 2.31 (58.7) Yes 1.25 (0.57) A L A 6.8 A 3.12 (79.4) 2.14 (54.4) 2.68 (68.2) Yes 1.6 (0.73) A L A 8.0A 2.50 (63.5) 2.52 (64.3) 3.00 (76.2) Yes 2.8 (1.27) A L A 10.8A 2.81 (71.4) 3.00 (76.2) 3.37 (85.7) Yes 4.1 (1.86) A L A 35.0A 3.12 (79.4) 3.14 (79.7) 3.75 (95.30) Yes 5.5 (2.49) Modification to standard parts and custom design available on request. Consult our application engineers to solve your specific need. Electrical schematics, mechanical outlines and data sheets available on PRONTO 24-hour Shipment Pronto 24-Hour Shipment: Our PRONTO shipment program is simple. We ship off-the-shelf products within 24 hours and in most cases the same day! Signal maintains an extensive finished goods inventory that enables us to ship small volume orders from stock. We are able to make this commitment because we constantly replenish our inventory through a computerized MRP system that computes inventory/production schedules to match our customers requirements. Large production orders are conservatively scheduled to ensure meeting JIT or any delivery requirements, even those with tight lead times. In fact, each year over 20,000 orders are shipped to satisfied customers on time, every time. Our capabilities website page will give you first hand insight to the advantage Signal Transformer can bring to your next design. Visit us at Contact us for your next wire wound magnetic application we can help! signaltransformer.com 11

12 MACHINE TOOL TRANSFORMER MTT / DMTT Series Power 300, 650 AND 1000 VA Ratings Dielectric Strength 4000 Vrms Hipot MTT Primaries Tapped Single 100, 115, 120V 50/60 Hz DMTT Primaries Tapped Dual configurations 200, 220, 240, 400, 440, 480V 50/60Hz Secondary - 120V and 2 x 12V with the following domestic and international standards: UL , UL 508, UL 60950, UL 197, IEC IEC , IEC , CSA 22.2 #66-1-2, VDE 0570, 0805, 0551, 0550 and CE Insulation Class F, 155 C MTT-300 (shown) E66312 Signal s MTT and DMTT transformers are designed to meet the requirements of commercial and heavy duty machine applications. Concentrically constructed platform provides both double reinforced insulation and excellent volumetric efficiency. Part Number VA Secondary RMS Rating Isolation Mechanicals Single Dual Size Series Parallel Voltage Length Width Height MTT-300 DMTT A 120V@ 2.5A 4.12 (104.8) 5.04 (128.1) 3.86 (98.2) Yes 9.82 (4.46) MTT-650 DMTT A 120V@5.42A 5.25 (133.3) 5.5 (139.7) 4.63 (117.8) Yes (9.01) MTT-1000 DMTT A 120V@ 8.33A 7.06 (179.3) 5.1 (129.6) 6.1 (154.9) Yes 33.5 (15.2) Modification to standard parts and custom design available on request. Consult our application engineers to discuss your specific design requirements. Electrical schematics, mechanical outlines and data sheets available on Technical Support Technical Support: Signal s staff of application and design engineers is one of the largest in the industry. Their extensive knowledge of regulatory and safety agency requirements insures expeditious handling of complex certification issues. Using the latest SPICE and CAD/CAM software, the Signal team stands ready to respond quickly to your unique, design and application needs. g Engineering Expertise g Manufacturing for more than 50 years g Our Willingness to Change g Strong Technical Support Contact us for your next wire wound magnetic application we can help! 12

13 CLASS 2 CL2 Series Power 25 VA to 80 VA Dielectric Strength 4000 Vms Hipot Primaries Dual 115/230V Secondaries - Single Secondary Class 2 Rating Insulation Class F, 155 C Terminals Solder Lug or Quick Connect UL Recognized to UL 1585, UL CSA Certified to C22.2 # CL (shown) Signal s CL2 transformers are available in printed circuit and chassis mount versions. They are supplied as inherently or non-inherently limited units that are UL 1585 / UL recognized. If you need more chassis space; ask about our DIN Rail mounting option. Part Number Secondary RMS Rating Secondary Fuse Required Mechanicals Length Width Height CL A 2.5A* 2.81 (71.4) 2.14 (54.4) 2.31 (58.7) Yes 1.25 (0.57) CL A 1.5A* 2.81 (71.4) 2.14 (54.4) 2.31 (58.7) Yes 1.25 (0.57) CL A 4.0A* 3.12 (79.4) 2.14 (54.4) 2.68 (68.2) Yes 1.6 (0.73) CL A 2.0A* 3.12 (79.4) 2.14 (54.4) 2.68 (68.2) Yes 1.6 (0.73) CL A 3.5A* 2.50 (63.5) 2.53(64.3) 3.00 (76.2) Yes 2.8 (1.27) Modification to standard parts and custom design available on request. Consult our application engineers with your specific design needs. Electrical schematics, mechanical outlines and data sheets available on * Non-Inherently limited Technical Support Technical Support: Signal s staff of application and design engineers is one of the largest in the industry. Their extensive knowledge of regulatory and safety agency requirements insures expeditious handling of complex certification issues. Using the latest SPICE and CAD/CAM software, the Signal team stands ready to respond quickly to your unique, design and application needs. g Engineering Expertise g Manufacturing for more than 50 years g Our Willingness to Change g Strong Technical Support Contact us for your next wire wound magnetic application we can help! signaltransformer.com 13

14 TWO-4-ONE - SPLIT BOBBIN 241 / DP-241 / MT / DMT Series Power 2.4 VA to 100 VA Dielectric Strength 2500 Vrms Hipot Primaries Single or Dual Secondary Center Tapped Triple Output MT/DMTs Split Bobbin Terminal Solder Lug / Quick Connects UL Recognized to UL 506, UL CSA Certified to C22.2 # DP (shown) Signal s 241 transformers utilize a split bobbin construction providing superior isolation and low capacitive coupling. The 241 and DP-241 series can easily be modified to any specific application. If you need more chassis space; ask about our DIN Rail mounting option or optional brackets. The MT / DMT series offer Triple Output option. Part Number Secondary RMS Mechanicals Rating Single 1145V Dual 115/230V Length Width Height Not Available A 2.07 (52.6) 1.17 (29.6) 1.23 (31.2) Yes 0.25 (0.11) DP A 2.37 (60.3) 1.31 (33.3) 1.43 (36.2) Yes 0.44 (0.20) DP A 2.81 (71.4) 1.43 (36.3) 1.69 (42.8) Yes 0.7 (0.32) DP A 3.25 (82.6) 1.74 (44.3) 1.96 (49.8) Yes 1.1 (0.50) DP A 3.68 (93.7) 1.94 (49.2) 2.28 (57.8) Yes 1.7 (0.77) DP A 4.03 (102.4) 2.30 (58.5) 2.67 (67.7) Yes 2.75 (1.25) Modification to standard parts and custom design available on request. Consult our application engineers with your specific design needs. Electrical schematics, mechanical outlines and data sheets available on Triple Output Part Number Secondary RMS Rating Mechanicals 1145V 115/230V Regulator 1 Regulator 2 Length Width Height MT-6-15 DMT A 3.25 (82.6) 1.74 ( (49.8) Yes 1.1 (0.50) MT-7-12 DMT A 350mA 3.68 (93.7) 1.94 (49.2) 2.28 (57.8) Yes 1.7 (0.77) MT-8-15 DMT A 500mA 4.03 (102.4) 2.30 (58.5) 2.67 (67.7) Yes 2.75 (1.25) Additional part numbers can be found on our website at Let us help you cut through the regulatory maze. Signal Transformer has In-House testing laboratory that can significantly speed your certification process and your product launch to market. Contact us for your next wire wound magnetic application we can help! 14

15 TWO-4-ONE WITH LEAD WIRES 241-L / DP-241-L Series Power 2.4 VA to 100 VA Dielectric Strength 2500 Vrms Hipot Primaries Single or Dual Secondary Center Tapped output Standard Length, Standard Color Lead Wires with UL 506, UL , CCA C22.2 # E66312 DP L (shown) The 241-L / DP-241-L series offers a Two-4-One with Single or Dual Input and 12 lead wires. Available in multiple configurations and in 6 standard VA sizes.. The 241-L / DP-241-L series can easily be modified to your specific application. Part Number Secondary RMS Mechanicals Rating Single 1145V Dual 115/230V Length Width Height L N/A A 2.07 (52.6) 1.17 (29.6) 1.23 (31.2) Yes 0.25 (0.11) L DP L A 2.37 (60.3) 1.31 (33.3) 1.43 (36.2) Yes 0.44 (0.20) L DP L (71.4) 1.43 (36.3) 1.69 (42.8) Yes 0.7 (0.32) L DP L A 3.25 (82.6) 1.74 (44.3) 1.96 (49.8) Yes 1.1 (0.50) L DP L 2.0A 3.68 (93.7) 1.94 (49.2) 2.28 (57.8) Yes 1.7 (0.77) L DP L A 4.03 (102.4) 2.30 (58.5) 2.67 (67.7) Yes 2.75 (1.25) L DP L A 4.03 (102.4) 2.30 (58.5) 2.67 (67.7) Yes 2.75 (1.25) Modification to standard parts and custom design available on request. Consult our application engineers with your specific design needs. Electrical schematics, mechanical outlines and data sheets available on Technical Support Technical Support: Signal s staff of application and design engineers is one of the largest in the industry. Their extensive knowledge of regulatory and safety agency requirements insures expeditious handling of complex certification issues. Using the latest SPICE and CAD/CAM software, the Signal team stands ready to respond quickly to your unique, design and application needs. Signal Transformer maintains an in-house ISO certified laboratory that enables us to participate in CSA s Shared Manufacturer Testing & Certification (SMTC) This program makes it possible to certify and use the CSA / ccsaus mark on new designs within days. Contact us for your next wire wound magnetic application we can help! signaltransformer.com 15

16 CONVENTIONAL RECTIFIER POWER TRANSFORMERS 1A TO 200A / 10 VA TO 2,800 VA Single / DL Series Power 10 VA to 2800 VA Dielectric Strength 1500 Vrms Hipot Primaries Single Tapped or Dual Primaries Conventional layer winding Secondaries Dual Center Tapped windings may be connected in Series or Parallel Over 17 standard configurations 10-1 (shown) Signal s rectifier power transformers provide a wide variety of outputs. This series of conservatively designed transformers is manufactured using traditional materials and layer wound techniques and can easily be modified to your exact specifications Part Number Secondary RMS Rating Mechanicals Single 1145V Dual 115/230V Series Parallel Length Width Height DL A 50A 4.50 (114.3) 3.75 (95.3) 3.75 (95.3) Yes 8.7 (3.95) DL A 200A 6.37 (162.0) 7.25 (184.2) 5.31 (134.9) Yes 34.5 (15.65) DL A 24A 4.50 (114.3) 4.50 (114.3) 3.75 (95.3) Yes 11.0 (4.99) 36-4 DL A 8A 4.12 (104.8) 3.37 (85.7) 3.43 (87.3) Yes 6.8 (3.08) Not Available A 100A 7.50 (190.5) 7.50 (190.5) 6.24 (158.8) Yes 56.3 (25.54) 68-6 DL A 12A 5.25 (133.4) 5.00 (127.0) 4.37 (111.1) Yes 15.0 (6.80) 80-1 DL A 2A 3.37 (85.7) 3.06 (77.7) 2.81 (71.4) Yes 4.0 (1.81) 24-6 DL A 12A 4.12 (104.8) 3.25 (82.6) 3.43 (87.3) Yes 5.8 (2.63) DL A 24A 6.37 (162.0) 6.00 (152.4) 5.31 (134.9) Yes 29.0 (13.15) Modification to standard parts and custom design available on request. Consult our customer service center to discuss your specific application. Electrical schematics, mechanical outlines and Data Sheets available on Additional part numbers can be found on our website at Pronto 24-Hour Shipment: Our PRONTO shipment program is simple. We ship off-the-shelf products within 24 hours and in most cases the same day! Signal maintains an extensive finished goods inventory that enables us to ship small volume orders from stock. Contact us for your next wire wound magnetic application we can help! 16

17 STEP DOWN AUTO TRANSFORMER EB Series Line cord Termination Power 100 VA to 2000 VA Voltage 230V to 115V Connection Line Cord & Receptacle NEMA 5-15 Style Chassis Mount Over 10 Standard Configurations High Insulation Class Available EB 110 (shown) Signal s auto transformers provide the user the capability of adapting voltages for worldwide applications. These step down Auto Transformer s are designed for chassis mount and can be easily modified to your exact application. VA Mechanicals Part Number Mounting Centers Size Length Width Height Complilant (47.6) 2.37 (60.3) 2.50 (63.5) 1.50 x 1.68 (38.1 x 42.8) Yes 1.5 (0.68) (73.0) 2.12 (54.0) 3.50 (88.9) 2.25 x 1.75 (57.2 x 44.5) Yes 3.0 (1.36) (73.0) 3.37 (85.7) 3.50 (88.9) 2.25 x 2.00 (57.2 x 50.8) Yes 3.5 (1.59) (73.0) 3.50 (88.9) 3.50 (88.9) 2.25 x 2.12 (57.2 x 54.0) Yes 4.0 (1.81) (73.0) 3.87 (98.4) 3.50 (63.5) 2.25 x 2.50 (57.2 x 63.5) Yes 4.8 (2.18) (82.6) 3.87 (98.4) 3.87 (98.4) 2.50 x 2.43 (63.5 x 61.9) Yes 5.5 (2.49) (82.6) 4.87 (123.8) 3.87 (98.4) 2.50 x 3.43 (63.5 x 87.3) Yes 8.0 (3.63) (82.6) 5.87 (149.2) 3.87 (98.4) 2.50 x 4.43 (63.5 x 112.7) Yes 11.0 (5.00) (114.3) 5.12 (130.2) 5.50 (139.7) 3.50 x 3.50 (88.9 x 88.9) Yes 14.0 (6.35) (114.3) 6.12 (155.6) 5.50 (139.7) 3.50 x 4.50 (88.9 x 114.3) Yes 20.0 (9.07) Modification to standard parts and custom design available on request. Consult our customer service center to discuss your specific application. Electrical schematics, mechanical outlines and Data Sheets available on Additional part numbers can be found on our website at Signal Transformer maintains an in-house ISO certified laboratory that enables us to participate in CSA s Shared Manufacturer Testing & Certification (SMTC) This program makes it possible to certify and use the CSA / ccsaus mark on new designs within days. Contact us for your next wire wound magnetic application we can help! signaltransformer.com 17

18 STEP DOWN AUTO TRANSFORMER OF Series Lead Wire Termination Power 100 VA to 2000 VA Voltage 230V to 115V or 115V to 230V Connection 8 Leads Chassis Mount Over 10 Standard Configurations Higher Insulation Class Available 110-OF (shown) Signal s auto transformers provide the user the capability of adapting voltages for worldwide applications. These step up / step down Auto Transformer s are designed for chassis mount and can be easily modified to your exact application. VA Mechanicals Part Number Mounting Centers Size Length Width Height Complilant 110 OF (57.2) 2.00 (50.8) 1.93 (49.2) 2.81 (71.4) Yes 1.3 (0.59) 112 OF (85.7) 2.50 (63.5) 2.87 (73.0) 2.81 x 1.87 (71.4 x 47.6) Yes 2.5(0.59) 115 OF (85.7) 2.75 (69.9) 2.87 (73.0) 2.81 x 2.12 (71.4 x 54.0) Yes 3.0 (1.36) 120 OF (85.7) 2.87 (73.0) 2.87 (73.0) 2.81 x 2.25 (71.4 x 57.2) Yes 3.5 (1.59) 125 OF (85.7) 3.25 (82.6) 2.87 (73.0) 2.81 x 2.62 (71.4 x 66.7) Yes 4.2 (1.90) 130 OF (95.3) 3.25 (82.6) 3.12 (79.4) 3.12 x 250 (79.4 x 63.5) Yes 5.0 (2.27) 150 OF (95.3) 4.25 (107.9) 3.12 (79.4) 3.12 x 3.50 (79.4 x 88.9) Yes 8.0 (3.63) 175 OF (95.3) 5.25 (133.4) 3.12 ( x 4.50 (79.4 x 114.3) Yes 11.0 (5.00) 1100-OF (133.4) 4.50 (114.3) 4.37 (111.1) 4.37 x 3.12 (111.1 x 79.4) Yes 14.0 (6.35) 1200-OF (133.4) 6.50 (165.1) 4.37 (111.1) 4.37 x 5.12 (111.1 x 130.2) Yes 25.0 (11.34) Modification to standard parts and custom design available on request. Consult our customer service center to discuss your specific application. Electrical schematics, mechanical outlines and Data Sheets available on Additional part numbers can be found on our website at Does your next design require a Common Mode Choke? Power Inductor? Linear Transformer? } We can help! We are your one stop for all your wire wound magnetic needs Contact us for your next wire wound magnetic application we can help! 18

19 FILTER AND DUAL CHOKES CH / CL Series Inductance 0.12 MHY to 100 MHY DC Current 1.0 A DC to 200 A DC Insulation System Class B Insulation 130 C Chassis Mount Over 20 Standard Configurations CH-1 (shown) Signal s CH and CL chokes are designed to complement the rectifier power transformers so that a set may be specified for DC power supplies using inductive filters. Both the CH and CL series are designed for chassis mount and quickly can be modified for any application Part Number Inductance MHY Current Amps Resistance Ohms Mechanicals Length Width Height Complilant CH (76.2) 2.50 (63.5) 2.50 (63.5) Yes 2.3 (1.04) CH (85.7) 2.75 (69.9) 2.87 (73.0) Yes 3.2 (1.45) CH (95.3) 3.12 (79.4) 3.25 (82.6) Yes 5.3 (2.40) CH (95.3) 3.62 (92.1) 3.25 (82.6) Yes 6.5 (2.95) CH (104.8) 3.62 (92.1) 3.50 (88.9) Yes 8.0 (3.63) CH (133.4) 4.00 (101.6) 4.43 (112.7) Yes 13.7 (6.21) CH (133.4) 4.62 (117.5) 4.43 (112.7) Yes 17.5 (7.94) CH (133.4) 4.00 (101.6) 4.43 (112.7) Yes 13.3 (6.03) CH (133.4) 4.75 (120.7) 4.43 (112.7) Yes 17.8 (8.07) CH (161.9) 5.00 (127.0) 5.37 (136.5) Yes 24.4 (11.07) CH (161.9) 5.25 (133.4) 5.37 (136.5) Yes 26.7 (12.11) CH (161.9) 6.25 (158.8) 5.37 (136.5) Yes 31.4 (14.24) Modification to standard parts and custom design available on request. Consult our application engineers with your specific design needs. Electrical schematics, mechanical outlines and data sheets available on CL Series / dual chokes are supplied with 2 windings for parallel or series connection. Check our website for schematics and available part numbers. Additional part numbers can be found on our website at Signal Transformer maintains an in-house ISO certified laboratory that enables us to participate in CSA s Shared Manufacturer Testing & Certification (SMTC) This program makes it possible to certify and use the CSA / ccsaus mark on new designs within days. Contact us for your next wire wound magnetic application we can help! signaltransformer.com 19

20 POWER ISOLATION DU / SU Series Power 250 VA to 10 KVA 500 VA to 20 KVA if used as Auto-Transformer Dielectric Strength 2500 Vrms Hipot Input Voltage Options: 104V, 110V, 120V, 208V, 220V, 230V, 240V Output Voltage options: (104V, 110V, 120V, 208V, 220V, 230V, 240V, 416V, 440V, 460V, 480V) Terminals Plated Brass Screw Type Available in High Insulation Class DU-1 /4 (shown) Signal s DU and SU transformers have been designed to provide a multitude of step-up or step down voltages to accommodate various input voltages available throughout the world. The DU and SU series are designed for chassis mount application. KVA Mechanicals Parallel Secondaries RoHs Part Number Size Volts Max Amps Volts Max Amps DU-1/4 or SU-1/4 1/4 0/208/220/ /104/110/ Yes 12 (5.44) DU-1/2 or SU-1/2 1/2 0/208/220/ /104/110/ Yes 18 (8.16) DU-1 or SU-1 1 0/208/220/ /104/110/120 9 Yes 33 (14.97) DU-2 or SU-2 2 0/208/220/ /104/110/ Yes 56 (25.40) DU-3 or SU-3 3 0/208/220/ /104/110/ Yes 70 (31.75) DU-5 or SU-5 5 0/208/220/ /104/110/ Yes 89 (40.37) DU-7.5 or SU /208/220/ /104/110/ Yes 105 (47.63) DU-10 or SU /208/220/ /104/110/ Yes 150 (68.04) Modification to standard parts and custom design available on request. Consult our customer service center to discuss your specific application. Electrical schematics, mechanical outlines and Data Sheets available on Additional part numbers can be found on our website at PRONTO 24-hour Shipment Pronto 24-Hour Shipment: Our PRONTO shipment program is simple. We ship off-the-shelf products within 24 hours and in most cases the same day! Signal maintains an extensive finished goods inventory that enables us to ship small volume orders from stock. We are able to make this commitment because we constantly replenish our inventory through a computerized MRP system that computes inventory/production schedules to match our customers requirements. Large production orders are conservatively scheduled to ensure meeting JIT or any delivery requirements, even those with tight lead times. In fact, each year over 20,000 orders are shipped to satisfied customers on time, every time. Capabilities Brochure Application Notes Agency Certification Brochure ALL available at our new website Contact us for your next wire wound magnetic application we can help! 20

21 TRANSFORMERS IN NEMA 3R COMPLIANT ENCLOSURES ICT Series Features Epoxy Encapsulated, impervious to atmospheric conditions Powder coated NEMA 3R compliant steel case Line Isolation and stray field filtering Bottom and or side conduit access Power: 500 VA to 1,800 VA in Isolation Power; 1,000 VA to 3,600 VA in Buck Boost Mode Suitable for both indoor and outdoor applications Standard input voltages 115, 230, 240 and 480 Standard Output Voltages 12, 16, 20, 24, and 115 Conforms to UL 506, 508 and Electrostatic screen (ESS) terminals CH-1 (shown) The ICT series is designed with flexibility to support both isolation and / or buck boost severe duty applications while offering many standard features. Select Your Product To order, simply select desired option from each category. For additional options not shown in this focus catalog consult our application engineers or visit our website at Series Designation ICT Input Voltage S 2 x 115V H 2 x 240V Case Size A 500 Isolation Mode, 1000 Buck Boost Mode B 1000 Isolation mode, 2000 Buck boost Mode C 1800 Isolation mode, 3600 buck boost Mode Part Number Example ICT-S-A-12 Output Voltage 12 2 x 12V 16 2 x 16V 20 2 x 20V 24 2 x 24V x 115V Plug Receptacle * P Plug Option Blank No Receptacle P (*) Configured for 115 V Single Output Note: Units with optional cords are for indoor use only Modification to standard parts and custom design available on request. Consult our customer service center to discuss your specific application. Electrical schematics, mechanical outlines and Data Sheets available on Plug Option (shown) Does your next design require a Common Mode Choke? Power Inductor? Linear Transformer? } We can help! We are your one stop for all your wire wound magnetic needs Contact us for your next wire wound magnetic application we can help! signaltransformer.com 21

22 THREE PHASE TRANSFORMERS Capabilities From small PC mount 10 VA transformer to large 45 KVA designs, we tailor these transformers to your specific needs. Our Three Phase transformers are designed for operation of 50 to 400 Hz frequency range, shielded or unshielded, and are suitable for a wide variety of applications from medical equipment to avionics systems. Configurations Transformers can be supplied prewired for D (Delta or Y (Wye) configurations for your specific installation requirements. Transformers are available with multiple taps, fuses, thermal cut-off, and multiple hardware and termination schemes. Our miniature Three Phase transformers are available for through hole (PCB) printed circuit board mounting Custom 3 Phase (shown) Materials Signal s Three Phase Transformers are constructed with copper windings and high grade steel core material assuring high efficiency and the lowest loss possible. These transformers are manufactured with high grade electrical insulation materials in order to meet the most demanding isolating applications and temperature requirements. Agency Approvals With our vast experience and multiple designs already registered and agency approved, Signal Transformer can expeditiously process your UL/CSA or any other certification and approval that you require. Go to to download our Agency Certification brochure or contact our engineering design center at Modification to standard parts and custom design available on request. Consult our customer service center to discuss your specific application. Electrical schematics, mechanical outlines and Data Sheets available on Signal Transformer is your one source for three phase transformers If your next deign requires a three phase transformer we can help! Visit us at 22

23 DIN RAIL - SPEEDY MOUNT Signal Transformer is your one source for wire wound magnetic solutions When a control transformer must be incorporated into industrial circuitry based on 35mm DIN rail, or replaced in the field, consider Signal s Speedy Mount series. Mounting these tech-friendly, DIN rail, power sources requires no loose hardware or tools and their slender design preserves available rail space. To mount, simply hook the transformer onto one flange, seat the unit on the rail and secure it using its two side locks. Then, finish up by plugging in your quick connect terminals and the job s done! Speedy Mount is available in sizes from 25 to 175VA. Our unique custom tailored multi-plane mounting configurations offer uninhibited access to terminal connections. Risk of rail twist due to mechanical shock or the transformer s overhung weight is countered by integral buttressing. Features No loose plates, hardware or screws to attach Mounting can be accomplished in under 30 seconds Allows for rapid, field up-sizing or replacement when necessary No tools required for mounting Minimal loss of rail space beyond transformer s basic footprint Firm grip on rail prevents sliding Choice of terminal location for horizontal & back-plane rail orientations Buttressed design guards against rail twist due to overhung weight when vertically mounted If your next design requires DIN rail mounting we can help! Signal Transformer designs, manufactures and markets high reliable customer, standard and modified standard wire wound magnetic solutions for most power conversion applications. With advanced manufacturing facilities and engineering expertise located worldwide. Tell us about your next power requirement-we can help! 23

24 CL2 Series Pages 25 LP Series Page 28 14A Series Page Triple Output MLP Series Page 28 Encapsulated IF Series Page 31 Triple Output ST/DST Series Page 29 PC/DPC Series Page 32 Encapsulated Triple Output All of the thru hole transformers can easily be modified. You can find the latest thru hole (PC Board mount) products on the home page of our new optimized website. LPI Series Page 30 MPC/DMPC Series Page 33 THRU HOLE MOUNT

25 CLASS 2 CL2 Series High Isolation UL 94-VO Rated Power 2.5 VA to 50 VA Dielectric Strength 4000 Vrms Hipot Secondaries Single Secondary Class 2 Rating Electrostatic Shield Not Needed UL Recognized to UL 1585 / UL Class 2 Flammability Rating UL 94V0 Class F Insulation System, 155 C CL2-2.5R-12 (shown) Signal s CL2 transformers are available in printed circuit and chassis mount versions. They are supplied as inherently or non-inherently limited units that are UL 1585 / UL recognized. Electrostatic shield not required due to reinforced insulation. Part Number Secondary RMS Rating Secondary RMS Rating Mechanicals Length Width Height Complilant CL2-2.5R A N/A* 1.62 (41.3) 1.43 (36.5) 1.12 (28.6) Yes 0.2 (0.11) CL2-2.5R A N/A* 1.62 (41.3) 1.43 (36.5) 1.12 (28.6) Yes 0.2 (0.11) CL2-5.0R A N/A* 1.62 (41.3) 1.43 (36.5) 1.37 (34.9) Yes 0.2 (0.11) CL2-5.0R A N/A* 1.62 (41.3) 1.43 (36.5) 1.37 (34.9) Yes 0.2 (0.11) CL2-10R A N/A* 1.87 (47.6) 1.56 (39.7) 1.37 (34.9) Yes 0.53 (0.24) CL2-10R A N/A* 1.87 (47.6) 1.56 (39.7) 1.37 (34.9) Yes 0.53 (0.24) CL A N/A* 2.25 (57.2) 1.87 (47.6) 1.62 (41.3) Yes 0.90 (0.41) CL A N/A* 2.25 (57.2) 1.87 (47.6) 1.62 (41.3) Yes 0.90 (0.41) CL A 3.0A** 2.62 (66.7) 2.18 (55.5) 1.56 (39.7) Yes 1.15 (0.52) CL A 2.5.A** 3.00 (76.2) 2.50(63.5) 1.81 (46.0) Yes 1.70 (0.77) Modification to standard parts and custom design available on request. Consult our customer service center to discuss your specific application. Electrical schematics, mechanical outlines and Data Sheets available on Additional part numbers can be found on our website at * Inherently Limited ** Non-Inherently Limited Our new website was designed by engineers for engineers Part Configurator Agency Certification Page Capabilities Page Market and Industry Page Buy On-Line e-commerce New Product alert Page Contact us for your next wire wound magnetic application we can help! signaltransformer.com 25

26 ONE-4-ALL INTERNATIONAL 14A Series High Isolation Power 2.5 VA to 56 VA Dielectric Strength Vms Hipot Dual Primaries 115/230V Dual Secondaries Series or Parallel 42 Standard Configurations UL Recognized to UL 506 / UL CSA Certified to C22.2 No VDE Certified to VDE 0805 / EN60950 Class F Insulation System, 155 C 14A-2.5R-10 (shown) Signal s 14A transformers are used in low power applications and provide the high isolation, creepage and clearance necessary to comply with international safety standards. Part Number VA Secondary RMS Rating Mechanicals Series Parallel Length Width Height 14A- 2.5R A 0.50A 1.62 (41.3) 1.43 (36.5) 1.12 (28.6) Yes 0.25 (0.113) 14A- 2.5R A 0.20A 1.62 (41.3) 1.43 (36.5) 1.12 (28.6) Yes 0.25 (0.113) 14A- 5.0R A 0.80A 1.62 (41.3) 1.43 (36.5) 1.37 (34.9) Yes 0.37 (0.168) 14A- 5.0R A 0.62A 1.62 (41.3) 1.43 (36.5) 1.37 (34.9) Yes 0.37 (0.168) 14A- 10R A 0.84A 1.87 (47.6) 1.56 (39.7) 1.37 (34.9) Yes 0.53 (0.240) 14A- 10R A 1.00A 1.87 (47.6) 1.56 (39.7) 1.37 (34.9) Yes 0.53 (0.240) 14A- 10R A 0.56A 1.87 (47.6) 1.56 (39.7) 1.37 (34.9) Yes 0.53 (0.240) 14A A 3.2A 2.25 (57.2) 1.87 (47.6) 1.62 (41.3) Yes 0.90 (0.41) 14A A 2.50A 2.62 (66.7) 2.18 (55.5) 1.56 (39.7) Yes 1.15 (0.52) 14A A 3.12 A 3.00 (76.2) 2.50 (63.5) 1.81 (46.0) Yes 1.70 (0.77) Modification to standard parts and custom design available on request. Consult our customer service center to discuss your specific application. Electrical schematics, mechanical outlines and Data Sheets available on Additional part numbers can be found on our website at Signal Transformer maintains an in-house ISO certified laboratory that enables us to participate in CSA s Shared Manufacturer Testing & Certification (SMTC) This program makes it possible to certify and use the CSA / ccsaus mark on new designs within days. Contact us for your next wire wound magnetic application we can help! 26

innovation in wire wound magnetic solutions

innovation in wire wound magnetic solutions Custom Transformers Custom Toroidal Custom Inductors Open Frame Enclosed Classic End Bells Lead Wires Ultra Sonic Welding Wire Termination Marking Abnormal / Fault Testing Potting Encapsulation Packaging

More information

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80 Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

Custom Products. Magnetic Components. Vishay Dale. www.vishay.com

Custom Products. Magnetic Components. Vishay Dale. www.vishay.com Magnetic Components SWITCH MODE MAGNETICS AIR CORE INDUCTORS INDUCTIVE PRODUCTS CUSTOM DESIGN AND PRODUCTION has extensive facilities for custom design and production of custom magnetics. Design applications

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Low Voltage Transformers Sealed, General Purpose, Dry Type

Low Voltage Transformers Sealed, General Purpose, Dry Type Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST 12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

innovation in wire wound magnetic solutions

innovation in wire wound magnetic solutions In-House Laboratory ISO 17025 CSA Shared Testing Test / Evaluate Certify Components Registered Delegates Reducing Lead Time Faster Approvals Engineering Expertise Technical Support Linear Transformers

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

IEC Connectors. Introduction

IEC Connectors. Introduction Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings

More information

Planar versus conventional transformer

Planar versus conventional transformer Planar versus conventional transformer Majid Dadafshar, Principal Engineer Gerard Healy, Field Application Engineer Pulse, a Technitrol Company Power Division Usually the first step on any power supply

More information

AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR

AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR The AC Series C type chassis receptacles feature two connectors in the one space saving housing. A combined XLR female receptacle together with a 6.35mm (1/4 )

More information

AC SERIES DUAL 1/4 (6.35mm) / XLR

AC SERIES DUAL 1/4 (6.35mm) / XLR AC SERIES DUAL 1/4 (6.35mm) / XLR The AC Series C type chassis receptacles feature two connectors in the one space saving housing. A combined XLR female receptacle together with a 6.35mm (1/4 ) phone jack

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Industrial Control Power Transformers

Industrial Control Power Transformers Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments

More information

1000 Series Miniature Slide Switches

1000 Series Miniature Slide Switches Miniature Switches Features/Benefits Variety of actuators and terminations Panel mount tabs available Epoxy terminal seal compatible with bottom-wash cleaning RoHS compliant Typical Applications Test &

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

AMVECO... Making a World of Difference in Toroidal Transformers.

AMVECO... Making a World of Difference in Toroidal Transformers. Monterrey, Meico Houston, Teas Salem, India Ningbo, China Shanghai, China (AIC) AMVECO... Making a World of Difference in Toroidal Transformers. AMVECO Magnetics, Inc. 11222 Richmond Ave. Suite 120 Houston,

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Grounding Demystified

Grounding Demystified Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%

More information

Universal MATE-N-LOK Connectors

Universal MATE-N-LOK Connectors Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

mpm DIN 43650 CONNECTORS

mpm DIN 43650 CONNECTORS mpm DIN 43650 CONNECTORS : Highest quality, robust connectors for hydraulic and pneumatic electromechanical devices Broad offering of DIN 43650 connectors and devices Combined Brad and mpm cordsets : Provide

More information

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER

More information

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH ENGLISH EMOSAFE EN-100 Product Data Sheet Network Isolators for PCB assembly November 2013 1 GENERAL DESCRIPTION The EMOSAFE EN-100 Network Isolator interrupts all galvanically conducting connections (conductors

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Transformers from 25va to 500kva. Standard despatch in days not weeks

Transformers from 25va to 500kva. Standard despatch in days not weeks Transformers from 25va to 500kva Standard despatch in days not weeks JMS Transformers Ltd 20 Ivatt Way Westwood Business Park Peterborough PE3 7PG UK Tel: +44 (0)1733 760000 Fax +44 (0)1733 760004 e-mail:

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Single Phase Three Phase Single Phase Export Model Transformers Single Phase Buck and Boost Transformers Stainless Steel Enclosed Transformers

Single Phase Three Phase Single Phase Export Model Transformers Single Phase Buck and Boost Transformers Stainless Steel Enclosed Transformers Transformers Selection Guide Description Page Three Phase Single Phase Aluminum, Copper, 150 Degree Rise Aluminum, Copper, 115 Degree Rise Aluminum, Copper, 80 Degree Rise Epoxy Encapsulated Aluminum,

More information

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Dialight Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Case Study: Rockline Case Study (Manufacturing)

More information

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

picomax The Pluggable Connection System

picomax The Pluggable Connection System picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Distribution Dry Type Transformers

Distribution Dry Type Transformers 8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Trapezoidal-Connectors Series TMC

Trapezoidal-Connectors Series TMC Trapezoidal-Connectors Series TMC Subminiature-D Connectors to DIN 41 652/IEC 807-3 General Series TMC connectors are available in 5 different housing sizes with 9, 15, 25, 37 and 50 pins. In applications

More information

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC QUICK REFERENCE DATA DESCRIPTION VALUE Ceramic Class 1 2 Ceramic Dielectric U2J U2J Y5S, Y5U Y5S, Y5U Voltage (V AC ) 500 760

More information

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5 AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO LED PORTFOLIO LUXEON LEDs Circuit Design and Layout Practices to Minimize Electrical Stress Introduction LED circuits operating in the real world can be subjected to various abnormal electrical overstress

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24 1 X CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),

More information

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

VLT Series 3500 Adjustable Frequency Drive Instruction Manual Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

5 Non-Ventilated Automation Transformers

5 Non-Ventilated Automation Transformers 5 Non-Ventilated Automation Transformers Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations as well as harsh industrial environments.

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu, APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP

More information

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02. Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11

More information

5 Non-Ventilated Automation Transformers

5 Non-Ventilated Automation Transformers 5 Non-Ventilated Automation Transformers Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations as well as harsh industrial environments.

More information

Buck - Boost Transformers

Buck - Boost Transformers Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single

More information

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Lighting Packages. 230 VAC Fluorescent Enclosure Light: Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for

More information

STB Series Enclosures

STB Series Enclosures STB Series Enclosures Features/Applications: The STB series of sheet steel enclosures are designed to meet the requirement for distribution and lighting junction boxes. Available in 14 sizes with standard

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

SMA Connectors. RF Coax Connectors. Product Facts

SMA Connectors. RF Coax Connectors. Product Facts SMA Connectors Product Facts Performance to 12.4 GHz and beyond Available in various base metal options, including stainless steel, brass and zinc diecast Uses industry standard crimp tools and processes

More information

MODEL 2202IQ (1991-MSRP $549.00)

MODEL 2202IQ (1991-MSRP $549.00) F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com

Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com CURRENT TRANSFORMER MODEL J " x 7" PAGE No 2-2 REV 8DEC00 TERMINAL OPTION LEAD WIRE OPTION 8-2 BRASS SCREW TERMINALS (2 PLACES) SEE NOTE 9 6 9 8 6 Ø 2 9 (4 PLACES) UL 05 #6 AWG LEAD WIRE, STANDARD LENGTH

More information

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under: REQUIREMENT : The equipment offered shall be highly reliable suitable to operate satisfactorily in hot humid and polluted climate. The equipments offered shall work satisfactorily within temperature range

More information

Features. Applications. Truth Table. Close

Features. Applications. Truth Table. Close ASSR-8, ASSR-9 and ASSR-8 Form A, Solid State Relay (Photo MOSFET) (0V/0.A/0Ω) Data Sheet Description The ASSR-XX Series consists of an AlGaAs infrared light-emitting diode (LED) input stage optically

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

SELECTION GUIDE. Nominal Input

SELECTION GUIDE. Nominal Input www.murata-ps.com NKE Series FEATURES RoHS Compliant Sub-Miniature SIP & DIP Styles 3kVDC Isolation UL Recognised Wide Temperature performance at full 1 Watt load, 40 C to 85 C Increased Power Density

More information

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)

Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E PCB Power elay The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of

More information

EMIT-3020L. Tel: 03-3980-2212. Analog Telephony / Modem Couplers DESCRIPTION. NOMENCLATURE (Fig. 1) MECHANICAL DIMENSIONS (Fig. 2)

EMIT-3020L. Tel: 03-3980-2212. Analog Telephony / Modem Couplers DESCRIPTION. NOMENCLATURE (Fig. 1) MECHANICAL DIMENSIONS (Fig. 2) EMIT-2L DESCRIPTION The REMtech Magnetics EMIT-2L is a Dry Encapsulated Modem Isolation Transformer suitable for up to V.9 (6 kbps) consumer and internet analog modem applications compliant with International

More information

Intersection Preassembled 19-inch Rack

Intersection Preassembled 19-inch Rack Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion

More information

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives

More information

DuroSite TM High Bay Lighting

DuroSite TM High Bay Lighting DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically

More information

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

The Different Types of AC Power Connectors in North America

The Different Types of AC Power Connectors in North America The Different Types of AC Power Connectors in North America White Paper 20 Revision 1 by James Spitaels > Executive summary A confusing array of AC power plugs and receptacles exist to deliver power to

More information

FASTON Terminals and Connectors

FASTON Terminals and Connectors Introduction Product Facts Straight, right-angle and receptacle-tab combinations available Receptacles available for 6.3 mm, 4.8 mm and 2.8 mm tab size (.250,.187 and.110 Series) Receptacles mate with

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

PS6500 Storage Arrays Rack Mount Instructions

PS6500 Storage Arrays Rack Mount Instructions PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks

More information

Assembly Instructions: Shortwave Radio Kit

Assembly Instructions: Shortwave Radio Kit Assembly Instructions: Shortwave Radio Kit MTM Scientific, Inc P.O. Box 522 Clinton, MI 49236 U.S.A Introduction Fig 1: The assembled Shortwave Radio Kit The SHORTWAVE RADIO KIT (#SWRAD) from MTM Scientific

More information

Top Microsystems Proprietary Specification P/N: W090015HK-XP 022410RB-082709V.A0 SPECIFICATION

Top Microsystems Proprietary Specification P/N: W090015HK-XP 022410RB-082709V.A0 SPECIFICATION SPECIFICATION High Quality Switching Wallmount Adapter Interchangeable AC Plugs 90-264VAC Input 13.5W 9VDC 1.5A Output P/N: W090015HK-XP ** Specification Approval** This specification (total 11 pages including

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Kit 106. 50 Watt Audio Amplifier

Kit 106. 50 Watt Audio Amplifier Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,