1 Gamma Radiography with Iridium 192 ADVANTAGES IN THE NON-DESTRUCTIVE TESTING OF CASTINGS AND WELDED STRUCTURES By R. A. Mintern and J. c. Chaston, Ph.D., A.R.S.M. Gamma radiography was introduced twenty years or so ago as a supplement to X-ray radiography to provide a means of inspecting castings, welded assemblies and other engineering structures for internal defects such as blowholes and cracks. This method of nondestructive testing has been developed alongside X-ray inspection and in general has been of special service where (a) radiographic examination has to be carried out in positions that would be inaccessible to bulky X-ray apparatus (b) relatively thick and dense metal parts are to be examined, since these would normally be beyond the range of ordinary X-ray equipment, the radiation from which is generally less penetrating than that from the gamma ray sources so far employcd. Originally the source of radiation was of course a naturally radioactive material. In the early days of gamma radiography it was usual to employ either permanently active sealed radium sources or short-lived sources filled with the radioactive gas radon drawn from a radium source. The radiation emitted from radium or radon is of a strongly penetrating character and experience showed that it was Gamma ray inspection, using iridium 192, of one of the welds in a tubular steel structure by Stewarts and Lloyds Ltd. Platinum Metals Rev., 1959, 3, (l),
2 An iridium 192 source in use for the non-dwtructive testing of a welded steel shell at the works of G. A. Harvey & Go. (London) Ltd. particularly suitable for the examination of thick castings of steel or copper alloys, Both these sources are still available but, since radioactive isotopes made artificially by irradiation in an atomic pile havc become available, it has been more customary to employ cobalt 60, which is an isotope of relatively long half life (5.3 years) and has proved a most attractive alternative to radium. The radiation emitted from cobalt 60 approximates to X-radiation generated at 1-18 million volts and, like that from radium, is suitable for examining heavy steel and iron castings up to six inches in section. More recently other radioactive isotopes have become available, including iridium 192, tantalum 182, caesium 137 and thulium 170. Of all these, the isotope iridium 192 has been found to have many particularly attractive characteristics. It is prepared by a neutrongamma reaction which takes place when a sample of metallic iridium of the required shape is inserted in the atomic pile. At the same time iridium 194 is also produced hut, as this has a half life of only 19 hours, the Gamma Ray Spectrum of Iridium 192 inergy of Spectrum Line I Relative Intensity (MeV) I3 I I I radiation from this isotope becomes negligible at the end of about one week. Iridium 192 which then remains, has a half life of 74.4 days. The nature of the radiation emitted by iridium 192 has been discussed by R. Halmshaw (I) who points out that the energy distribution in the gamma ray spectrum is complex and is probably not far removed from that quoted by Muller (2) and his colleagues and shown in the table. The work of Halmshaw suggests that a slightly larger proportion of the higher energy spectrum lines than are indicated by this table may be present, and from experiments with exposure curves he concludes that the radiation from iridium 192 is roughly equivalent to that from an X-ray tube running at a peak voltage of 800 to 900 kv. From theoretical reasoning it is very difficult to compare the value of different sources of gamma radiation, hut Halmshaw has shown that the radiation from iridium 192 is, as would be expected, inferior to 200 kv Platinum Metals Rev., 1959, 3, (1) 13
3 or 400 kv X-rays for detection of fine cracks, but that the flaw sensitivity, when considered in terms of contrast alone, is actually comparable with 400 kv X-rays for thicknesses from 14 to 3 inches of steel and, although considerably less than that with zoo kv X-rays, remains reasonable for thicknesses down to about 4 inch steel provided that good film processing technique is followed. More recently, W. H. Sansom (3) has confirmed from considerable experience that there is a relatively high, and rather unexpected, degree of image contrast obtained when radiographing comparatively thin sections of steel [with iridium 1921-even down to 7 Ib plate, which, with reinforcement, is approximately inch. Sansom reports that in the radiographic examination of the shell or hull of a ship the use of an iridium 192 source in conjunction with a medium-speed non-screen film between four and six thousandths lead screens, has produced results which, for all practical purposes, bear very favourable comparison with exographs taken under similar conditions. In the case of steel sections in excess of one inch, there becomes progressively less and less to choose between the exograph and gammagraph in terms of contrast and sensitivity and, if time allows, with the use of a fine-grain non-screen film for the gammagraph, the difference becomes negligible. He further points out that it may be said from experience, with some degree of certainty, that, in spite of the considerably longer exposures necessary with an iridium 192 source of medium or low strength (the exposure times with a high-strength source may be very close to the corresponding X-ray exposure), the actual volume of work over a given period is little different from that achieved by the use of X-rays-in some cases, it may actually be higher. This comparison is set in terms of a relatively small department with a staff of three or, at the most, four operators working each unit. The reason for this is to be found in the great bulk and weight of an X-ray unit, with its necessary ancillary services of coolant and power, as compared to an isotope container or bomb. Radiographic Technique In order to derive the full advantage from the use of a gamma-ray source of iridium 192 it is important that attention should be given to all details of radiographic technique. For a radiograph to give the maximum information the exposure given must be sufficient to penetrate the thickest part of the object and to produce a good density on the film when developed. Film processing must be closely controlled to obtain the maximum contrast and minimum graininess, but this is Platinum Metals Rev., 1959, 3, (1) 14
4 comparatively easy compared with determining the correct exposure required. The exposure time will depend on the strength of the source, the distance it is placed from the film, the thickness, density and atomic number of the material being radiographed and the speed of the film, but the relationship is complicated and is best dealt with by preparing an exposure chart. Exposure Charts An exposure chart prepared for steel will be of general use for copper and its alloys. The method usually employed for making an exposure chart is to take a series of radiographs of a step-wedge of the metal concerned at the same distance from the source for different exposure times. The wedge used to produce the figures for the steel graph shown here consisted of strips of inch tool steel arranged in steps from 1, to I+ inches. This was backed up by ;t inch strips to obtain figures for thicknesses up to 2 inches. The range of densities was read off on a film densitometer for each of the radiographs which had been processed in Ilford PQX I developer for six minutes at 68'F. The results are expressed in curie-hours for a film density of The exposure is expressed in curie-hours to enable the chart to be used for any strength source. The film used was Ilford type F, a slow fine-grained film which will give the maximum sensitivity to flaw detection. Faster films can be used in certain applications where maximum sensitivity is not required and where a reduction in exposure time is an advantage. A further series of exposures was made with a lead step-wedge to illustrate the effect of increased density and atomic number. The A portable isotope carrier and time-rontrolled exposure unit in use fqr the gamma radiography of a number of copper alloy castings in the foundry of Mallory Metallurgical Products Ltd. Platinum Metals Rev., 1959, 3, (1) 15
5 slope of the curves is very different for thin sections, lead requiring much greater increase in exposure between + and inch than steel. Over this range radiographs of far greater contrast can be obtained with lead and other metals of high density and atomic number such as platinum and its alloys. The reason for this is probably that the gamma-rays from iridium cover a range of energies from 0.30 to 0.61 mev and as lead has a much higher absorption coefficient than steel the lower energy rays are stopped more readily. Protection of Operators It is important that radio-active isotopes should be handled in such a way that radiation received by operators is kept to a minimum. A check should be kept on the amount of radiation received by carrying film badges or ionisation chambers. The maximum permissible dose from iridium 192 for continuous working is 0.3 rontgens per week. The radiation from an unshielded source is 0.5 milli-rontgens,/hour/milli-curie. A 2-curie radiographic source would therefore give a week s radiation in 20 minutes at a distance of one metre. Availability of Sources Iridium sources are available from the Atomic Energy Research Establishment, Hanvell, in four standard sizes in the form of cylinders with their length equal to their diameter, the sizes being 6 X 6 mm, 4X 4 mm, 2 X 2 mm and I X I mm, and also as wire I mm diameter and as foil 0.05 inch thick. References I R. Halmshaw The Use and Scope of Iridium 192 for the Radio- graphy of Steel, Briz. J. Appl. Physics, 1954, 5, D. E. Muller, H. C. Hoyt, D. J. Klein Precision Measurements of Nuclear Gamma Ray and J. W. M. DuMond.... Wave Lengths, Phys. Rev., 1952,88, W. H. Sansom Some Reflections on the use of Radioisotopes in Industrial Radiography, Shipbuilder, 1957, 64, RHODIUM PLATED PRINTED CIRCUITS Printed circuit techniques based on conventional etched, copper-clad laminates are well established for the manufacture of multi-way switches. Such techniques greatly simplify construction and reduce manufacturing time and cost. Electrodeposited rhodium is generally accepted as the most satisfactory means of providing such switches with wearresistant, tarnish-free contact surfaces. Used in conjunction with suitable goldalloy or palladium-alloy brush materials these switches give low values of contact resistance and electrical noise coupled with a surprisingly long life. The illustration shows the nine-inch stator of a 200-way switch to be used in telemetry equipment. The rhodium has been deposited on the contact surfaces of the 200 sectors as well as on the two slip rings in the centre. Originally the stator had an outside band of copper linking the sectors, as well as a connecting strip to the two slip rings, to permit plating. Platinum Metals Rev., 1959, 3, (1) 16
Radiation and the Universe Higher Exam revision questions and answers
Radiation and the Universe Higher Exam revision questions and answers Madeley High School Q.The names of three different processes are given in List A. Where these processes happen is given in List B.
X-ray 100KV. Speed as compared to that of type IX100 used as a standard 100 under each exposure conditions.
DATA SHEET INDUSTRIAL RADIOGRAPHIC SYSTEMS RADIOGRAPHIC FILM IX20, IX25, IX50, IX80, IX, IX, IX29 AND IX59 Fujifilm industrial X-ray films feature revolutionary new film technology. The combination of
FEATURES AND BENEFITS OF DIFFERENT PLATINUM ALLOYS. Kris Vaithinathan and Richard Lanam Engelhard Corporation
FEATURES AND BENEFITS OF DIFFERENT PLATINUM ALLOYS Kris Vaithinathan and Richard Lanam Engelhard Corporation Introduction There has been a significant increase in the world wide use of platinum for jewelry
NON DESTRUCTIVE TESTING & ASNT WELD INSPECTION & AWS
NON DESTRUCTIVE TESTING & ASNT WELD INSPECTION & AWS What is ASNT? What is ASNT? The American Society for Nondestructive Testing, Inc. What is ASNT? ASNT is the world's largest technical society for nondestructive
X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission
Principles of Imaging Science I (RAD119) X-ray Production & Emission X-ray Production X-rays are produced inside the x-ray tube when high energy projectile electrons from the filament interact with the
Non-Destructive Testing
Non-Destructive Testing Minimize Product Line Downtime and Product Loss with Radiography Testing for Sorting and Containment Authored by Mike Forbes, Na onal Sales Manager TUV Rheinland Industrial Solu
proper way. Therefore operator training and certification is key in every inspection program to ensure compliance and improve quality and integrity.
SGS NDT Training & Examination Centre Professional Services for Your Safety and Reputation ABOUT NON DESTRUCTIVE TESTING (NDT) About NDT NDT plays a key role in assessing conformity and reliability of
Cutting Edge Digital Radiography Technology in Daily NDT Use
Cutting Edge Digital Radiography Technology in Daily NDT Use Ron PINCU, Eli DAYAN, Ofra KLEINBERGER Vidisco Ltd. Or-Yehuda, Israel 60375 Tel: +972 (3) 533-3001 Email: [email protected] ABSTRACT Digital Radiography
Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9
Module 9 This module presents information on what X-rays are and how they are produced. Introduction Module 9, Page 2 X-rays are a type of electromagnetic radiation. Other types of electromagnetic radiation
Radioactivity III: Measurement of Half Life.
PHY 192 Half Life 1 Radioactivity III: Measurement of Half Life. Introduction This experiment will once again use the apparatus of the first experiment, this time to measure radiation intensity as a function
Radiation Strip Thickness Measurement Systems
Radiation Strip Thickness Measurement Systems During the past years we have increased our sales of radiometric Vollmer strip thickness measurement systems, i.e. X-ray or isotope gauges, dramatically. Now,
Optimization of Digital Industrial Radiography (DIR) Techniques for Specific Applications: An IAEA Coordinated Research Project
IV Conferencia Panamericana de END Buenos Aires Octubre 2007 Optimization of Digital Industrial Radiography (DIR) Techniques for Specific Applications: An IAEA Coordinated Research Project U. Ewert, U.
A VERSATILE COUNTER FOR CONVERSION MÖSSBAUER SPECTROSCOPY
A VERSATILE COUNTER FOR CONVERSION MÖSSBAUER SPECTROSCOPY I. BIBICU 1, G. NICOLESCU 2, L. CIOLACU 2, L. SERBINA 2 1 National Institute for Materials Physics, Bucharest 77125, Romania, [email protected] 2
Handbook on the Ultrasonic Examination. Austenitic Welds
Handbook on the Ultrasonic Examination Austenitic Welds The International Institute of Welding Edition Handbook On the Ultrasonic Examination of Austenitic Welds Compiled by COMMISSION V Testing, Measurement,
W. C. Reinig. Savannah River Laboratory E. I. du Pent de Nemours and Company Aiken, South Carolina 298o1
.*. *.-a /dp73j/3~ DP-MS-68-48 calforn1um-252: A NEW SOTOPC SOUR(!EFOR NEUTRON RADOGRAPHY by W. C. Reinig Savannah River Laboratory E.. du Pent de Nemours and Company Aiken, South Carolina 298o1. SRL7
X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION
X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION David Bernard Dage Precision Industries Inc. Fremont, California [email protected] ABSTRACT The x-ray inspection of PCB assembly processes
Standard Test Method for Classification of Film Systems for Industrial Radiography 1
Designation: E 1815 96 (Reapproved 2001) Standard Test Method for Classification of Film Systems for Industrial Radiography 1 This standard is issued under the fixed designation E 1815; the number immediately
1. Orthovoltage vs. megavoltage x-rays. (AL) External beam radiation sources: Orthovoltage radiotherapy: 200-500 kv range
1. Orthovoltage vs. megavoltage x-rays. (AL) External beam radiation sources: Orthovoltage radiotherapy: 200-500 kv range The radiation from orthovoltage units is referred to as x-rays, generated by bombarding
Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise
TDK EMC Technology Product Section Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise TDK Shonai Corporation Satoru Saito Reduce Emission Noise from Cables Even if an electronic
Intelligent Measurement and Diagnostic Techniques for Non-destructive Inspections
Intelligent Measurement and Diagnostic Techniques for Non-destructive Inspections 296 Intelligent Measurement and Diagnostic Techniques for Non-destructive Inspections Fuminobu Takahashi, D. Eng. Shigeru
X-ray Imaging Systems
Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures
Introduction to Geiger Counters
Introduction to Geiger Counters A Geiger counter (Geiger-Muller tube) is a device used for the detection and measurement of all types of radiation: alpha, beta and gamma radiation. Basically it consists
Production of X-rays and Interactions of X-rays with Matter
Production of X-rays and Interactions of X-rays with Matter Goaz and Pharoah. Pages 11-20. Neill Serman Electrons traveling from the filament ( cathode) to the target (anode) convert a small percentage
PHYSICS PAPER 1 (THEORY)
PHYSICS PAPER 1 (THEORY) (Three hours) (Candidates are allowed additional 15 minutes for only reading the paper. They must NOT start writing during this time.) ---------------------------------------------------------------------------------------------------------------------
............... [2] At the time of purchase of a Strontium-90 source, the activity is 3.7 10 6 Bq.
1 Strontium-90 decays with the emission of a β-particle to form Yttrium-90. The reaction is represented by the equation 90 38 The decay constant is 0.025 year 1. 90 39 0 1 Sr Y + e + 0.55 MeV. (a) Suggest,
CENTRIFUGAL CASTING. Email: [email protected] [email protected]
CENTRIFUGAL CASTING Amit M Joshi (B.Engg. Mechanical, A.M.I.Prod.E, A.I.E) Dept. of Metallurgical Engg. & Material Science, Indian Institute of Technology Bombay, India. Email: [email protected] [email protected]
Coating Thickness and Composition Analysis by Micro-EDXRF
Application Note: XRF Coating Thickness and Composition Analysis by Micro-EDXRF www.edax.com Coating Thickness and Composition Analysis by Micro-EDXRF Introduction: The use of coatings in the modern manufacturing
Nuclear Science Merit Badge Workbook
Merit Badge Workbook This workbook can help you but you still need to read the merit badge pamphlet. The work space provided for each requirement should be used by the Scout to make notes for discussing
SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9
CHAPTER TIG welding Introduction pages - & - WELDING POWER SOURCES DC power sources SMARTY 60 POWER page -5 SMARTY 80 / 0 XL page -6 SMARTY TX 50 page -7 AC/DC power sources SMARTY TX 60 Alu page -8 SMARTY
The Limitations of Hand-held XRF Analyzers as a Quantitative Tool for Measuring Heavy Metal Pesticides on Art Objects. By Özge Gençay Üstün
N.B. A shorter version of this article was published in the ICOM-CC Ethnographic Conservation Newsletter, Number 30, January 2009, pp. 5-8. The Limitations of Hand-held XRF Analyzers as a Quantitative
11. NONDESTRUCTIVE TESTING
11. NONDESTRUCTIVE TESTING Nondestructive testing includes magnetic particle testing (MT), Liquid Dye Penetrant testing (PT), Radiographic Testing (RT) and Ultrasonic Testing (UT). The purpose of nondestructive
NONDESTRUCTIVE INSPECTION OF HULL WELDS
Guide for Nondestructive Inspection of Hull Welds GUIDE FOR NONDESTRUCTIVE INSPECTION OF HULL WELDS SEPTEMBER 2011 (Updated February 2014 see next page) American Bureau of Shipping Incorporated by Act
From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?
From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation? From lowest energy to highest energy, which of the following correctly
Unit 1 Practice Test. Matching
Unit 1 Practice Test Matching Match each item with the correct statement below. a. proton d. electron b. nucleus e. neutron c. atom 1. the smallest particle of an element that retains the properties of
CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.
Lanair Clean Burn CABINET Lanair's lightweight heat exchanger provides very little travel for the heat to be picked-up and ultimately be transferred to your shop. It uses a 2-pass design made up of 12
A Brief Description of NDT Techniques
A Paper By Mark Willcox & George Downes Telephone +44 (0)1981 541122 Fax +44 (0)1981 541133 Email [email protected] Web Site www.insightndt.com Insight NDT Equipment Ltd The Old Cider Mill Kings Thorn
For convenience, we may consider an atom in two parts: the nucleus and the electrons.
Atomic structure A. Introduction: In 1808, an English scientist called John Dalton proposed an atomic theory based on experimental findings. (1) Elements are made of extremely small particles called atoms.
Safety and Radiation Protection Office Working with X-Ray Equipment
Safety and Radiation Protection Office Working with X-Ray Equipment Radiation Safety Rules May 2016 Radiation Safety Rules X-Ray Equipment General Rules for the protection of persons exposed to ionising
Single-Phase AC Synchronous Generator
ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description
The Existence of a Neutron
J. Chadwick, PRSL, A136, 692 1932 The Existence of a Neutron J. Chadwick (Received 1932) It was shown by bothe and becker that some light elements when bombarded by α particles of polonium emit radiations
5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION
5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION 5.2.1 Task The bremsstrahlung produced by the X-ray tube has a continuous spectrum, limited by the set and spreads
Magnesium TM. Soil Anodes. High Potential Magnesium. Production - Quality Control. Laboratory- Testing. Packaging- Availability
Magnesium TM Soil Anodes High Potential Magnesium SuperMag High Potential Magnesium Anodes from Galvotec Alloys, Inc. offers typical high workingldriving potentials of -1.70 volts or better vs. copperlcopper
SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES
Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY DIAGNOSTIC (VETERINARY) SECTION 1:
Technical Notes NDT 001 Specific Requirements for Non- Destructive Testing Laboratories
ACCREDITATION SCHEME FOR LABORATORIES Technical Notes NDT 001 Specific Requirements for Non- Destructive Testing Laboratories Technical Notes NDT 001, Apr 14 The SAC Accreditation Programme is managed
Experiment 10. Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado
1 Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado Introduction Some radioactive isotopes formed billions of years ago have half- lives so long that they are
Balzers Sputter Coater SCD 050
Balzers Sputter Coater SCD 050 The SCD 050 is a bench top, sputter deposition system designed for thin films on substrates up to 6 inches. Morphology and thickness is user controlled using power, pressure,
DC MOTOR ANALYSIS & TROUBLESHOOTING
DC MOTOR ANALYSIS & TROUBLESHOOTING By Don Shaw Condition assessment of DC motors requires a basic understanding of the design and operating characteristics of the various types available: the series motor,
Thursday 13 June 2013 Morning
THIS IS A NEW SPECIFICATION H Thursday 13 June 2013 Morning GCSE TWENTY FIRST CENTURY SCIENCE PHYSICS A A182/02 Modules P4 P5 P6 (Higher Tier) *A137290613* Candidates answer on the Question Paper. A calculator
Coating Technology: Evaporation Vs Sputtering
Satisloh Italy S.r.l. Coating Technology: Evaporation Vs Sputtering Gianni Monaco, PhD R&D project manager, Satisloh Italy 04.04.2016 V1 The aim of this document is to provide basic technical information
TARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
Basic Concepts of X-ray X Fluorescence by Miguel Santiago, Scientific Instrumentation Specialist
Basic Concepts of X-ray X Fluorescence by Miguel Santiago, Scientific Instrumentation Specialist University of Puerto Rico Mayagüez Campus Department of Geology X-ray / Microanalysis Laboratory F - 304
X-ray Imaging Systems
Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures
WELDING & CUTTING MAIN EQUIPMENT
GASES DIVISION GAS WELDING & CUTTING EQUIPMENT WELDING & CUTTING MAIN EQUIPMENT GAS WELDING & CUTTING KIT The MARIGASES GAS WELDING AND CUTTING KIT is a high quality set containing all the tools and components
Basics of Nuclear Physics and Fission
Basics of Nuclear Physics and Fission A basic background in nuclear physics for those who want to start at the beginning. Some of the terms used in this factsheet can be found in IEER s on-line glossary.
RADIATION SAFETY STANDARD
Radiation Safety Act 1999 RADIATION SAFETY STANDARD NM004:2010 Standard for radiation apparatus used to carry out industrial radiography Preface Under section 17 of the Radiation Safety Act 1999, a possession
Dental Radiography collimator Ionising radiation image radiolucent area radiopaque area controlled zone scatter radiation intraoral
Dental Radiography X-rays for dental radiography are produced by high voltages of electricity within an x-ray head and come out through a metal tube called a collimator. This ensures the x-rays only come
Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D.
OSNA -10 Copper-Nickel Lined Pipes Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D. KME Germany AG & Co. KG Copper-Nickel Lined Pipes [GB] Member of the KME Group
Ultrasonic Wave Propagation Review
Ultrasonic Wave Propagation Review Presented by: Sami El-Ali 1 1. Introduction Ultrasonic refers to any study or application of sound waves that are higher frequency than the human audible range. Ultrasonic
Main properties of atoms and nucleus
Main properties of atoms and nucleus. Atom Structure.... Structure of Nuclei... 3. Definition of Isotopes... 4. Energy Characteristics of Nuclei... 5. Laws of Radioactive Nuclei Transformation... 3. Atom
Atomic and Nuclear Physics Laboratory (Physics 4780)
Gamma Ray Spectroscopy Week of September 27, 2010 Atomic and Nuclear Physics Laboratory (Physics 4780) The University of Toledo Instructor: Randy Ellingson Gamma Ray Production: Co 60 60 60 27Co28Ni *
Radioactivity & Particles
Radioactivity & Particles Introduction... 2 Atomic structure... 2 How are these particles arranged?... 2 Atomic notation... 4 Isotopes... 4 What is radioactivity?... 5 Types of Radiation: alpha, beta and
Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies
Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies (Ci), where 1 Ci = 3.7x10 10 disintegrations per second.
Industrial tracers - Finding leaks and blockages
Cancer Treatment Alpha radiation is used to treat various forms of cancer. This process, called unsealed source radiotherapy, involves inserting tiny amounts of radium-226 into cancerous organs. The alpha
ABSORPTION OF BETA AND GAMMA RADIATION
ABSORPTION OF BETA AND GAMMA RADIATION The purpose of this experiment is to understand the interaction of radiation and matter, and the application to radiation detection and shielding Apparatus: 137 Cs
OR Technology. Non Destructive Testing (RT) Strong Workmate for
OR Technology Strong Workmate for Non Destructive Testing (RT) Who We Are What We Do OR Technology Digital X-ray and Imaging Solutions producing digital X-ray technology and developing image management
THE STRAIN GAGE PRESSURE TRANSDUCER
THE STRAIN GAGE PRESSURE TRANSDUCER Pressure transducers use a variety of sensing devices to provide an electrical output proportional to applied pressure. The sensing device employed in the transducers
Selection, use and maintenance of portable monitoring instruments
HSE information sheet Selection, use and maintenance of portable monitoring instruments Ionising Radiation Protection Series No 7 Introduction The Ionising Radiations Regulations 1999 (IRR99) 1 require
USE OF IONIZING RADIATION IN THE TEACHING OF PHYSICS AND CHEMISTRY
GUIDE ST 5.3 / 4 MAY 2007 USE OF IONIZING RADIATION IN THE TEACHING OF PHYSICS AND CHEMISTRY 1 Ge n e r a l 3 2 Safety licences and exemption from licensing 3 3 Safety licence-exempt use of radiation 3
Anodes and Misc Equipment
Anodes and Misc Equipment Application: Platinised Titanium Anodes Platinised titanium anodes are recommended for use in the following electrolytic processes:- Precious metal electroplating - e.g. Au, Pt,
Basic RTD Measurements. Basics of Resistance Temperature Detectors
Basic RTD Measurements Basics of Resistance Temperature Detectors Platinum RTD resistances range from about 10 O for a birdcage configuration to 10k O for a film type, but the most common is 100 O at 0
Sheet Metal Stamping Dies & Processes
Training Objectives After watching the program and reviewing this printed material, the viewer will gain knowledge and understanding of the stamping process and the die systems used to form sheet metal.
Electromagnetic (EM) waves. Electric and Magnetic Fields. L 30 Electricity and Magnetism [7] James Clerk Maxwell (1831-1879)
L 30 Electricity and Magnetism [7] ELECTROMAGNETIC WAVES Faraday laid the groundwork with his discovery of electromagnetic induction Maxwell added the last piece of the puzzle Heinrich Hertz made the experimental
Submitted to Radiation Measurements INVESTIGATION OF OSL SIGNAL OF RESISTORS FROM MOBILE PHONES FOR ACCIDENTAL DOSIMETRY
Submitted to Radiation Measurements INVESTIGATION OF OSL SIGNAL OF RESISTORS FROM MOBILE PHONES FOR ACCIDENTAL DOSIMETRY A. Mrozik, B. Marczewska, P. Bilski, W. Gieszczyk Institute of Nuclear Physics PAN,
Aluminium as Construction Material in Ammonia Refrigeration Cycles
Aluminium as Construction Material in Ammonia Refrigeration Cycles Experiences With Aluminium Compared to other metals, aluminium has only a brief history as an engineering material. While, about 150 years
DIRECT CURRENT GENERATORS
DIRECT CURRENT GENERATORS Revision 12:50 14 Nov 05 INTRODUCTION A generator is a machine that converts mechanical energy into electrical energy by using the principle of magnetic induction. This principle
Problems in Welding of High Strength Aluminium Alloys
Singapore Welding Society Newsletter, September 1999 Problems in Welding of High Strength Aluminium Alloys Wei Zhou Nanyang Technological University, Singapore E-mail: [email protected] Pure aluminium has
HSE information sheet Industrial radiography - managing radiation risks Ionising Radiation Protection Series No. 1(rev 1)
HSE information sheet Industrial radiography - managing radiation risks Ionising Radiation Protection Series No. 1(rev 1) Introduction This information sheet is for clients and main or principal contractors
Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered
Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered vs. Wall-Mount X-Ray X Systems Edgar Bailey*, MSEHE, CHP Consultant Joel Gray*, PhD, FAAPM DIQUAD, LLC
ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Liquid Hydrogen Storage - Takuji Hanada, Kunihiro Takahashi
LIQUIDHYDROGEN STORAGE Takuji Hanada Air Liquide Japan Co., Ltd., Tokyo, Japan Kunihiro Center for Supply Control and Disaster Management, Tokyo Gas Co., Ltd., Tokyo, Japan Keywords: liquidhydrogen, insulation
Level 3 Science, 2008
90732 3 907320 For Supervisor s Level 3 Science, 2008 90732 Describe selected properties and applications of EMR, radioactive decay, sound and ultrasound Credits: Four 2.00 pm Thursday 20 November 2008
Raptor high-performance cone crushers
Raptor high-performance cone crushers Raptor high-performance cone crushers Key value statements Largest cone crusher in the world (Raptor 000) Most diverse product line on the market Continual focus on
Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.
Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc. Abstract The technology for connecting lead and magnet wires for electric motors and electro mechanical devices
Ch. 227 ANALYTICAL X-RAY EQUIPMENT 25
Ch. 227 ANALYTICAL X-RAY EQUIPMENT 25 CHAPTER 227. RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT, X-RAY GAUGING EQUIPMENT, ELECTRON MICROSCOPES AND X-RAY CALIBRATION SYSTEMS Sec. 227.1.
SECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES
SECTION 33 05 16.13 PRECAST CONCRETE PART 1 - GENERAL 1.01 SECTION INCLUDES A. This item shall consist of the construction of both sanitary and storm sewer precast concrete manholes in accordance with
The Models of the Atom
The Models of the Atom All life, whether in the form of trees, whales, mushrooms, bacteria or amoebas, consists of cells. Similarly, all matter, whether in the form of aspirin, gold, vitamins, air or minerals,
METHODS FOR THE CALIBRATION OF ELECTROSTATIC MEASURING INSTRUMENTS
METHODS FOR THE CALIBRATION OF ELECTROSTATIC MEASURING INSTRUMENTS Contents Foreword --------------------------------------------------------------------------------------------------------------------
Introduction to Nuclear Physics
Introduction to Nuclear Physics 1. Atomic Structure and the Periodic Table According to the Bohr-Rutherford model of the atom, also called the solar system model, the atom consists of a central nucleus
INNOVATIVE ELECTROMAGNETIC SENSORS
Technical Progress on INNOVATIVE ELECTROMAGNETIC SENSORS FOR PIPELINE CRAWLERS Type of Report: Technical Progress Report Reporting Period Start Date: October 7, 2003 Reporting Period End Date: April 30,
Flash Butt Welding Machines
Flash Butt Welding Machines Types AS 15 - AS 320 Flash butt welding current brake current (ka) current time flattening reversal preheating welding time flash butting forging A reliable and economic process
Lecture 2 Macroscopic Interactions. 22.106 Neutron Interactions and Applications Spring 2010
Lecture 2 Macroscopic Interactions 22.106 Neutron Interactions and Applications Spring 2010 Objectives Macroscopic Interactions Atom Density Mean Free Path Moderation in Bulk Matter Neutron Shielding Effective
INDIAN STANDARDS (BIS) ON WELDING
** IS 82:957 Glossary of terms relating to welding and cutting of Sep 2008 metals 2 IS 83:986 Scheme of symbols for welding (revised) Sep 2008 3 IS 84:2004 Covered electrodes for manual metal arc welding
Ultrasonic Reference Blocks
Ultrasonic Reference Blocks Custom and Standard Test Blocks for Nondestructive Testing Introduction 3 IIW Type 1 Calibration Block 4 Miniature Angle Beam (ROMPAS) Calibration Block 4 Distance Calibration
Shaft grounding. Carbon brushes for shaft grounding are used in turbo-generators, in distinct AC- and DC motors and as a special application in Ships.
"Modern AC-Motors don't need carbon brushes and are maintenance free " Until some years ago this thrilling statement could be heard from motor OEM's. Nowadays SCHUNK supplies carbon brushes and brush holders
How to Conduct a Magnet Pull Test
1 How to Conduct a Magnet Pull Test Many manufacturers today invest thousands if not millions of dollars annually into magnetic separation equipment, proactively reducing the risk that any foreign object
Pillbox Antenna for 5.6 GHz Band Dragoslav Dobričić, YU1AW [email protected]
Pillbox Antenna for 5.6 GHz Band Dragoslav Dobričić, YU1AW [email protected] Introduction The pillbox or cheese antenna is made of two parallel plates which are connected to the narrow strip of parabolic
4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:
4 SENSORS The modern technical world demands the availability of sensors to measure and convert a variety of physical quantities into electrical signals. These signals can then be fed into data processing
A Comparison of an HPGe-based and NaI-based Radionuclide Identifier (RID) for Radioactive Materials
Illicit Trafficking, Sub/cross-national threats, Poster presentation A Comparison of an HPGe-based and NaI-based Radionuclide Identifier (RID) for Radioactive Materials Ronald M. Keyser, Timothy R. Twomey,
Industrial Radiography Image forming techniques
GE Inspection Technologies Industrial Radiography Image forming techniques GE imagination at work 2007 General Electric Company. All Rights Reserved. We reserve the right to technical modifications without
A-level PHYSICS (7408/1)
SPECIMEN MATERIAL A-level PHYSICS (7408/1) Paper 1 Specimen 2014 Morning Time allowed: 2 hours Materials For this paper you must have: a pencil a ruler a calculator a data and formulae booklet. Instructions