Next Generation Ethernet (NGBASE-T) Beyond Ethernet 10GBASE-T - What does the future hold?

Size: px
Start display at page:

Download "Next Generation Ethernet (NGBASE-T) Beyond Ethernet 10GBASE-T - What does the future hold?"

Transcription

1 Next Generation Ethernet (NGBASE-T) Beyond Ethernet 10GBASE-T - What does the future hold? Contents: 1. Scope 2. Ethernet market potential 3. Improvement opportunities for NGBASE-T 4. TE Connectivity activities 5. Conclusions 1. Scope This technical paper provides an overview of the future of Ethernet networking technologies that use twisted pair copper cabling. It also covers the progress of the IEEE standard group that is responsible for defining requirements and also the compatibility of new standards with existing Ethernet services. Firstly, the document explains the necessity for increased network speeds in data center environments. Secondly, it reviews improvement opportunities for passive infrastructure transmission performance to help avoid IC design constraints that would otherwise increase the need for large and costly digital signal processing (DSP) cores to be used. The use of large DSP cores contributed to some of the delays witnessed in the take up of 10GbE. The document concludes by explaining how TE Connectivity is currently at the vanguard of the standards activity and using state of the art design to develop solutions for the transmission requirements to accommodate all current standard proposals.

2 2. Ethernet market potential: Ethernet has become the most widely implemented network physical layer data technology used to support the transfer, process and storage of data across local area networks. The main reason for its success has been the ability to keep the cost per bit at reasonable levels, while traffic has grown exponentially. Cost of installation, simplicity, upgradeability and ease of maintenance are other factors that have helped Ethernet consolidate its position as the preferred option for data transmission. Transmission speed rates have increased rapidly over the last three decades, but the arrival of new communication services like mobile 4G, video distribution, cloud services, storage backup, etc. with the associated huge demand for data transmission will be a real challenge for Ethernet to support, especially in data centers. Fig 1 CPU Performance Drives Network Speeds Networking Speed (Mbps) CPU Performance (MIPS) >8yrs Ethernet Speed CPU Performance 40Gb 3+yrs yrs yrs Time Figure 1 - The Market Need for 40G (Sun Microsystems presentation to IEEE 802.3ba Task Force) The main physical transmission media used are fiber optics and twisted pair copper cabling. Fiber optics technology has always led the way as higher baud rates have initially been deployed, but, historically, it has been matched soon afterwards by twisted pair copper cabling supporting the same speeds, but with more competitive installation costs driving wide market acceptance. Twisted pair copper cabling is the most adopted physical medium in LAN applications, especially for the horizontal distribution of Ethernet services; but it has also achieved significant penetration in data center networks due to its flexibility when implementing the Top of Rack, Middle of Row, and End of Row topologies that are widely deployed in data centers today. Page 2

3 3. Improvement opportunities for NGBASE-T: Currently, the maximum transmission speed that can be achieved with existing twisted pair copper cabling is 10Gbps. The supporting IEEE 802.3an standard, which defines the transmission parameters for 10Gbps Ethernet, was released in June 2006 after three years of work collecting the requirements for compatibility with previous Ethernet services and the accepted topologies. The topologies specified for 10Gbps were based on those that already existed for lower transmission rates and they were mainly designed with office cabling installations in mind, not data centers. As a result, 10Gbps Ethernet active equipment (switches, routers, etc.) had to deliver data transmission up to 10Gbps for a 100m channel configuration of four-connectors for both shielded and unshielded cabling. These requirements placed a constraint upon silicon device designs (referred to as PHY from now on) that, in turn, significantly delayed the uptake of 10Gbps Ethernet technology by the market. The IEEE 802.3bq standard group, which is responsible for defining Next Generation BASE-T, has highlighted some improvement opportunities for cabling infrastructure, with the aim of having the new digital communication service deployed quickly into the market. These improvement opportunities include the following: 1) Shorter network topologies: NGBASE-T (40GBASE-T) is being developed mainly for data centers where the distances between active equipment (switch to server or switch to storage device) are significantly shorter. Reducing channel lengths means higher signal-noise ratios are acceptable and this helps reduce power consumption, one of the most important issues to consider. Fig 2 ToR switches 3.5W/port EoR switches 6W/port Figure 2 - Table of per port power consumption required for typical DC topologies Source: IEEE 802.3bq standard group for 40GBASE-T 2) Support for shielded cabling only: minimizing Alien Crosstalk (noise crosstalk which occurs among adjacent cables) was an important requirement for ensuring the proper operation of Ethernet 10GBASE-T; therefore systems based on unshielded cabling were more vulnerable to this effect. Today, almost everybody accepts the need for shielded solutions to assure the required electromagnetic isolation for NGBASE-T (40GbE). As a result, even many of the cabling manufacturers that lobbied to keep the unshielded configuration for the 10GBASE-T standard have abandoned their position, supporting shielded configurations only for the new standard. Fig 3 Example of how noise crosstalk affects adjacent cables Page 3

4 3) Align the twisted pair copper cabling requirements from TIA and ISO/IEC: These are the two standard bodies that collect the transmission needs from the IEEE standard group for 40GBASE-T and define the cabling standards. Both have open working groups for defining the transmission requirements for the new Ethernet standard. TE Connectivity is contributing to the drafting of both documents with the desired aim of aligning the transmission requirements and avoiding some of the confusion that happens today in the market for 10GbE where TIA and ISO/IEC differs in some requirements. Fig 4 ISO vs TIA Cat. 6A Comp ISO Cat. 6A Comp TIA Cat. 6A Comp 50.0 NEXT in db db Frequency in MHz 1000 ISO/IEC nd Ed. Amd.2 vs TIA-568-C.2 Cat6A NEXT component requirement Example of requirement s divergence The cabling standard working groups are considering two scenarios; the first is called Class I or Cat.8 (depending of the standard body) based on Category 6A style components and the second is Class II based on Category 7A style components. Both scenarios extend the requirements up to 2GHz with the latter being the more demanding. 4) Include the internal layout of the active equipment for channel modelling: Taking the influence of the internal elements of the active equipment (magnetics, track layout, etc.) into consideration in the cabling model during the requirements definition stage, will help with the signal integrity requirements and consequently, reduce power consumption for data post-processing. Fig 5 Equipment Patch Panel Patch Panel Equipment PHY MDI Patch Cord Patch Cord Patch Cord MDI PHY Traditional Structured Cabling CHANNEL MDI connector magnetics and trace length PHY-2-PHY CHANNEL 2-connector Channel configuration for 40GBASE-T Including MDI and Internal layout Page 4

5 4. TE Connectivity activities At TE Connectivity, we are actively participating in the relevant standards groups and our engineers are currently working on innovative designs based on the well known RJ45 interface, achieving excellent results that meet the transmission requirements currently defined by TIA Cat.8 (draft 0.9 Aug 9th 2013) and ISO/IEC Class I (draft N2121 Apr 17th 2013) and take into consideration the backward compatibility with existing Ethernet services. Fig 6 TE Connectivity RJ45 prototype Transmission performance against ISO/IEC Class I (draft N2121 Apr 17th 2013) Even prior to this, we had anticipated the need to design a data connector for higher speed Ethernet applications by launching the AMP-TWIST 7AS SL Jack in The jack already offers premium performance above the Cat. 7A frequency limit of 1000MHz while keeping the well known features of our AMP-TWIST SL Jack family. This connector already meets the strongest requirements of ISO/IEC Class II (draft N2121 Apr 17th 2013) currently defined for 40GBASE-T. Fig 7 AMP-TWIST 7AS SL Jack Transmission performance against ISO/IEC Class II (draft N2121 Apr 17th 2013) Page 5

6 5. Conclusions 40Gb/s servers and switched ports are currently being shipped around the world, and the need to design the network in a data center for future upgrade to those transmission speeds is key. Today the only viable option for transmitting 40Gb/s packets further than 7m in a data center is fiber. The IEEE, TIA and ISO/IEC standards bodies have begun to define the electrical and physical characteristics for channels that will give customers the flexibility to use copper twisted pair technology to transmit 40Gb/s Ethernet traffic. However, there are no parameters currently specified that active equipment vendors can use to design equipment for 40GBASE-T. This in turn means that any designer of a data center network infrastructure cannot confidently design a copper network today for 40GBASE-T transmission, unless they chose to deploy a point to point direct attach network over limited distances. Some of the areas within the cabling standard that still require definition include: 1. Measurement methods at the higher frequencies required to support 40GBASE-T 2. Interoperability between the connectivity solutions of different manufacturers 3. Field verification methods of the installed cabling However, there are a number of areas of agreement that have emerged from the standards activities that give clear direction on the way that things are likely to develop: 1. RJ45 is preferred choice for the Media Device Interface (MDI) connector for 40GBASE-T because of its wide adoption within the industry and its familiar form factor. However, other connectors may be considered if they deliver superior performance. 2. Stronger performance requirements are needed for cabling compared to previous generations of Ethernet to help minimize PHY design complexity and decrease power consumption. 3. Screened products will be necessary to achieve, by design, the stronger electromagnetic immunity requirements that are anticipated. 4. Extending the channel modelling from chip-to-chip is likely with the aim of assuring the data signal integrity and reducing data post-processing. TE Connectivity is a driving force within the 40GBASE-T copper standards activities and is helping to give active vendors information on what is possible to achieve from the physical layer. As we move closer to the proposed publication date for a 40GBASE-T structured cabling standard, sometime in 2015, the physical and electrical parameters will become better defined and TE Connectivity will be part of ensuring customers are given the best possible cabling infrastructure solution available to meet those needs. It is currently too early in the process to make claims of 40GBASE-T performance for cabling solutions and everyone should be cautious when hearing such claims. We are committed to helping network designers, installers and end users to build new data centers ready for 40GBASE-T, while retaining the flexibility inherent within a structured cabling approach to deliver an agile data center.w Page 6

7 TE ENTERPRISE NETWORKS REGIONAL SALES HEADQUARTERS: North America Greensboro, NC, USA Ph: Fx: Latin America Buenos Aires, Argentina Ph: Fx: EMEA Kessel-Lo, Belgium Ph: Fx: SAARC Bangalore, India Ph: Fx: Asia Hong Kong, China Ph: Fx: Pacific Sydney, Australia Ph: Fx: TE ENTERPRISE NETWORKS IN EUROPE, MIDDLE EAST AND NORTH AFRICA: Austria Vienna Ph: Fx: Belarus Minsk Ph: Fx: Belgium Kessel-Lo Ph: Fx: Bulgaria Sofia Ph: Fx: Czech Rep. & Slovakia Brno Ph: Fx: Denmark Glostrup Ph: Fx: Egypt Cairo Ph: Fx: Finland Helsinki Ph: Fx: France Cergy-Pontoise Ph: Fx: Germany Darmstadt Ph: Fx: Hungary Budapest Ph: Fx: Italy Collegno (Torino) Ph: Fx: Kazakhstan Almaty Ph: Fx: Lithuania Vilnius Ph: Fx: Netherlands Den Bosch Ph: Fx: Norway Nesbru Ph: Fx: Poland Warsaw Ph: Fx: Portugal Evora Ph: Fx: Romania Bucharest Ph: Russia Moscow Ph: Fx: Spain Montcada (Barcelona) Ph: Fx: Sweden Upplands Väsby Ph: Fx: Switzerland Steinach Ph: Fx: Turkey Istanbul Ph: Fx: U.A.E. Dubai Ph: Fx: UK Tewkesbury, Glos Ph: Fx: Ukraine Kiev Ph: Fx: WHITE PAPER Contact us: Please contact us at one of the regional offices shown above. TE Enterprise Networks: TE Connectivity: TE Connectivity, TE connectivity (logo), Tyco Electronics, and TE (logo) are trademarks of the TE Connectivity Ltd. family of companies and its licensors. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity's obligations shall only be as set forth in TE Connectivity's Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved EU 12/13 Revision 2013

24 fiber MPOptimate Configuration and Ordering Guide

24 fiber MPOptimate Configuration and Ordering Guide -Fiber System Overview -FIBER TRUNKING SOLUTIONS Bandwidth and storage demand is expanding at a breathtaking rate. The environment is rapidly evolving. The impact on data center design and management is

More information

Data Center Infrastructure Solution

Data Center Infrastructure Solution Data Center Infrastructure Solution Agile & Efficient Agile, Efficient & Highly Available Data Centers Data center deployment is at the heart of most IT strategies. Designing a data center that responds

More information

Know Your Network. managed connectivity. Transforming Your Physical Layer into a Strategic Asset

Know Your Network. managed connectivity. Transforming Your Physical Layer into a Strategic Asset Know Your Network Transforming Your Physical Layer into a Strategic Asset it S time to truly KNoW YoUR NetWoRK higher availability Reduced opex ITIL process efficiency integration of physical and logical

More information

AMP CO Ultra System Catalog

AMP CO Ultra System Catalog Catalog Table of Contents AMP CO Ultra Panels... 1 AMP CO Ultra Outlets... 3 AMP CO Inserts... 7 AMP CO Tools...16 AMP CO Ultra Panels AMP CO Ultra 24 Port High Density Patch Panel 19 2 U Patch Panel for

More information

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks HIGHSPEED ETHERNET THE NEED FOR SPEED Jim Duran, Product Manager - Americas WHITE PAPER Molex Premise Networks EXECUTIVE SUMMARY Over the years structured cabling systems have evolved significantly. This

More information

CATEGORY 8: UNDERSTANDING THE NEW CATEGORY OF PERFORMANCE FOR BALANCED TWISTED PAIR CABLE

CATEGORY 8: UNDERSTANDING THE NEW CATEGORY OF PERFORMANCE FOR BALANCED TWISTED PAIR CABLE ORTRONICS : UNDERSTANDING THE NEW CATEGORY OF PERFORMANCE FOR BALANCED TWISTED PAIR CABLE Cindy Montstream, RCDD/NTS, EE, CPLP Director of elearning and Standards DATA COMMUNICATIONS Legrand, North America

More information

Data Centre Functional Areas

Data Centre Functional Areas 1. Scope This technical paper is intended to provide guidance in Data Centre planning and design consideration with main reference to latest technology and largely adopted Data Centres deployment strategies.

More information

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable June 10, 2010 Contributors: Yinglin (Frank) Yang CommScope, Inc. Charles Seifert Ixia Ethernet Alliance 3855 SW 153 rd

More information

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling

More information

White Paper: What Component Compliance Means for CAT6A System Performance

White Paper: What Component Compliance Means for CAT6A System Performance White Paper: What Component Compliance Means for CAT6A System Performance Gary Bernstein, RCDD Director of Product Management Copper Systems Leviton Network Solutions Jeff Seefried Development Engineering

More information

Cisco IT Data Center and Operations Control Center Tour

Cisco IT Data Center and Operations Control Center Tour Cisco IT Data Center and Operations Control Center Tour Inside the Build Room Page 1 of 8 5. Inside the Build Room Introduction Figure 1. Inside the Build Room Ian: The purpose of the Build room is for

More information

IFS ApplIcAtIonS For Document management

IFS ApplIcAtIonS For Document management IFS Applications for Document management OUR SOLUTION S DNA When we first set out to create IFS Applications over 25 years ago, our goal was to make the most usable business software on the market. And

More information

Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram

Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram www.psiberdata.com Agenda Market Market Trend and Trend business and and business case for case higher

More information

Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk

Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk Introduction At the IEEE 802.3 Working Group meeting in July of 2012, the Next Generation BASE-T Call for

More information

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems Asef Baddar, RCDD Principal Engineer / Applications Engineering Supervisor Leviton Network Solutions C/7 - #1928 Table of Contents Background

More information

Data Center Architecture with Panduit, Intel, and Cisco

Data Center Architecture with Panduit, Intel, and Cisco Data Center Architecture with Panduit, Intel, and Cisco 0GBASE-T Application Note Integrating Panduit Category 6A Interconnects with the Cisco Nexus TM and Intel Ethernet Server Adapter X0-T 0 PANDUIT

More information

Category 8 Cabling Standards Update

Category 8 Cabling Standards Update White Paper Category 8 Cabling Standards Update TIA TR42.7 Study Group for Class II Limits Contents 1 Background 3 2 Impact of this approval on Category 7 A cabling 3 3 Differences between Class I and

More information

How To Get 40G Over Copper (Wired) And 40G On Coaxian (Wireless) Cable (Wired Coaxian) (Wired Cable) (Wireline) (Powerline) And 50G Over Coaxian Cable (Wire Coaxian

How To Get 40G Over Copper (Wired) And 40G On Coaxian (Wireless) Cable (Wired Coaxian) (Wired Cable) (Wireline) (Powerline) And 50G Over Coaxian Cable (Wire Coaxian Copper for Beyond 10GBASE-T David Zambrano Agenda Market Drivers Standards Cabling and Ethernet Field Test Considerations Agenda Market Drivers Standards Cabling and Ethernet Field Test Considerations

More information

White Paper. Cat. 6A vs. Cat. 6 A. What s the Difference and Why Should I Care?

White Paper. Cat. 6A vs. Cat. 6 A. What s the Difference and Why Should I Care? White Paper Cat. 6A vs. Cat. 6 A What s the Difference and Why Should I Care? Cat. 6A vs. Cat. 6 A What s the Difference and Why Should I Care? TABLE OF CONTENTS 1. Introduction...3 2. Component Standards

More information

Intelligent Infrastructure Management System

Intelligent Infrastructure Management System Intelligent Infrastructure Management System System Overview AMPTRAC Hardware Overview Unused Port Patched Port AMPTRAC System and Components AMPTRAC Basic Operating Principle Robust th wire in patch cords

More information

The AMP NETCONNECT Cabling System Products

The AMP NETCONNECT Cabling System Products The AMP NETCONNECT Cabling System Products About the AMP NETCONNECT Business Unit The AMP NETCONNECT business unit of Tyco Electronics develops, manufactures and supplies a comprehensive range of communications

More information

Network/Multimedia Cables

Network/Multimedia Cables Network/Multimedia Cables For LAN Installation, Home/Office Use Cat. 5, 6 Ethernet Cables Multi-Mode & Single-Mode Fiber Cables KVM Cables USB 2.0 Cables 1394 (FireWire) Cables F or the benefit of one-stop

More information

Network Design. Yiannos Mylonas

Network Design. Yiannos Mylonas Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which

More information

M8 / M12 CONNECTOR SYSTEM

M8 / M12 CONNECTOR SYSTEM M8 / M12 CONNECTOR SYSTEM EVERY CONNECTION COUNTS TE CONNECTIVITY S M8 / M12 Connector System for machine industrial automation and control applications provides a solution that safely and reliably ensures

More information

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company Data Centre Cabling 20 August 2015 Stefan Naude RCDD The SIEMON Company Agenda 1. Data Centre Standards 2. The Need for Speed 3. Copper in the Data Centre 4. Fibre in the Data Centre 5. Top of Rack vs

More information

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications 3M Telecommunications Solutions for Networks Volition Network Solutions Leading the way in Network Migration through Innovative Connectivity Solutions Innovation The Broadband Migration Path 3M TM Volition

More information

Enhanced Category 5 Cabling System Engineering for Performance

Enhanced Category 5 Cabling System Engineering for Performance Engineering for Performance Table of Contents 2 Introduction 2 Where Did It Come From? 2 Enhanced Category 5 Performance What to Test The Link The Channel Don t Forget the Cable Assembly 4 Performance

More information

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Questions to Ask When Planning the Cabling Plant Planning a copper cabling plant to support 10Gbps transmission

More information

Method for improving Return Loss in order to reduce PHY power Ron Nordin Panduit Bob Wagner Panduit Paul Vanderlaan Berk-Tek

Method for improving Return Loss in order to reduce PHY power Ron Nordin Panduit Bob Wagner Panduit Paul Vanderlaan Berk-Tek Method for improving Return Loss in order to reduce PHY power Ron Nordin Panduit Bob Wagner Panduit Paul Vanderlaan Berk-Tek Supporters Mike Grimwood Broadcom Will Bliss Broadcom Dariush Dabiri APM Dan

More information

Quick Reference Guide High Speed Input/Output Solutions

Quick Reference Guide High Speed Input/Output Solutions Quick Reference Guide The pluggable I/O interface offers significant advantages as a high speed I/O interconnect. With a standard equipment I/O interface and the flexibility of pluggable modules come the

More information

Schedule 2t. Additional terms for Fast Trade - Online Ordering

Schedule 2t. Additional terms for Fast Trade - Online Ordering 1. SERVICE DESCRIPTION Fast Trade is a high quality bandwidth service specifically designed for customers who require extremely low latency and low packet loss on links between two Network Termination

More information

Integrated telecommunication solutions

Integrated telecommunication solutions Integrated telecommunication solutions 1 About THE Linx Group Our extensive industry experience have already helped many multinational clients The Linx Group (known under Linxtelecom and Linxdatacenter

More information

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter Data Sheet Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter To meet the continual need for increased router features and performance, Cisco Systems introduces its newest packetover-sonet (POS) port

More information

802.11ac Power Measurement and Timing Analysis

802.11ac Power Measurement and Timing Analysis 802.11ac Power Measurement and Timing Analysis Using the 8990B Peak Power Analyzer Application Note Introduction There are a number of challenges to anticipate when testing WLAN 802.11ac [1] power amplifier

More information

Data Center Infrastructure Development

Data Center Infrastructure Development Data Center Infrastructure Solution Agile & Efficient Agile, Efficient & Highly Available Data Centers Data center deployment is at the heart of most IT strategies. Designing a data center that responds

More information

Data Center. www.datacenter.rdm.com

Data Center. www.datacenter.rdm.com Cover photo 090.6323 www.datacenter.rdm.com Data Center Headquarters Reichle & De-Massari AG Binzstrasse 32 CHE-8620 Wetzikon/Switzerland Phone +41 (0)44 933 81 11 Fax +41 (0)44 930 49 41 www.rdm.com Your

More information

QuickSpecs. HP Wireless Keyboard and Mouse. Models

QuickSpecs. HP Wireless Keyboard and Mouse. Models Overview 1. Wireless Keyboard 2. USB Wireless Transceiver 3. Wireless Mouse Models QY449AA Introduction The combine a cordless keyboard, cordless laser mouse, and USB wireless receiver in a single package.

More information

einvoice A fully automated digital solution for companies of all sizes

einvoice A fully automated digital solution for companies of all sizes einvoice A fully automated digital solution for companies of all sizes 2 IFS einvoice How much are you on your invoices? How about hundreds of labor hours? The expense of postage? Costly errors? And a

More information

Security & Surveillance Cabling Systems

Security & Surveillance Cabling Systems Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.

More information

High Speed Data Networking for the Automotive Market

High Speed Data Networking for the Automotive Market High Speed Data Networking for the Automotive Market 2 Tyco Electronics Ltd. is a leading global provider of engineered electronic components, network solutions and wireless systems, with customers in

More information

NetFlow Feature Acceleration

NetFlow Feature Acceleration WHITE PAPER NetFlow Feature Acceleration Feature Description Rapid growth in Internet and intranet deployment and usage has created a major shift in both corporate and consumer computing paradigms. This

More information

41 T Korea, Rep. 52.3. 42 T Netherlands 51.4. 43 T Japan 51.1. 44 E Bulgaria 51.1. 45 T Argentina 50.8. 46 T Czech Republic 50.4. 47 T Greece 50.

41 T Korea, Rep. 52.3. 42 T Netherlands 51.4. 43 T Japan 51.1. 44 E Bulgaria 51.1. 45 T Argentina 50.8. 46 T Czech Republic 50.4. 47 T Greece 50. Overall Results Climate Change Performance Index 2012 Table 1 Rank Country Score** Partial Score Tendency Trend Level Policy 1* Rank Country Score** Partial Score Tendency Trend Level Policy 21 - Egypt***

More information

How To Get A New Phone System For Your Business

How To Get A New Phone System For Your Business Cisco Phone Systems Telemarketing Script Cold Call 1. Locate Contact: Name listed Owner General Manager / Office Manager Chief BDM (Business Decision Maker) Note: Avoid talking to IT since this is not

More information

DDR Memory Overview, Development Cycle, and Challenges

DDR Memory Overview, Development Cycle, and Challenges DDR Memory Overview, Development Cycle, and Challenges Tutorial DDR Overview Memory is everywhere not just in servers, workstations and desktops, but also embedded in consumer electronics, automobiles

More information

Global AML Resource Map Over 2000 AML professionals

Global AML Resource Map Over 2000 AML professionals www.pwc.co.uk Global AML Resource Map Over 2000 AML professionals January 2016 Global AML Resources: Europe France Italy Jersey / Guernsey 8 Ireland 1 Portugal 7 Luxembourg 5 United Kingdom 1 50 11 Spain

More information

How To Get The Ifs Cloud On Microsoft Azure 2.5 On A Microsoft Cloud On A Cloud On An Ios 2.4.5 (Cloud) On A Server On A Supermicrosoft Cloud (Cloud On A Mini

How To Get The Ifs Cloud On Microsoft Azure 2.5 On A Microsoft Cloud On A Cloud On An Ios 2.4.5 (Cloud) On A Server On A Supermicrosoft Cloud (Cloud On A Mini IFS CLOUD ON MICROSOFT AZURE YOU RE ALWAYS READY TO POUNCE 2 IFS CLOUD ON MICROSOFT AZURE IFS CLOUD ON MICROSOFT AZURE 3 MAKE YOUR MOVE POISED FOR ANY OPPORTUNITY CLOUD AS YOU WANT IT It s a busy and fast-moving

More information

Data Communications Competence Center

Data Communications Competence Center Importance of Cable Balance For Improving Noise Susceptibility Data Communications Competence Center DCCC03101702 July 11, 2007 Summary In a study of category 5e and category 6 UTP cables, a strong correlation

More information

Cisco Secure Access Control Server Solution Engine

Cisco Secure Access Control Server Solution Engine Data Sheet Cisco Secure Access Control Server Solution Engine The Cisco Secure Access Control Server (ACS) provides a comprehensive identity networking solution and secure user experience for Cisco intelligent

More information

HIGH-DENSITY PACKET VOICE DIGITAL SIGNAL PROCESSOR MODULE FOR CISCO IP COMMUNICATIONS SOLUTION

HIGH-DENSITY PACKET VOICE DIGITAL SIGNAL PROCESSOR MODULE FOR CISCO IP COMMUNICATIONS SOLUTION DATA SHEET HIGH-DENSITY PACKET VOICE DIGITAL SIGNAL PROCESSOR MODULE FOR CISCO IP COMMUNICATIONS SOLUTION PRODUCT OVERVIEW The High-Density Packet Voice digital signal processor (DSP) (PVDM2) enables Cisco

More information

CISCO METRO ETHERNET SERVICES AND SUPPORT

CISCO METRO ETHERNET SERVICES AND SUPPORT SERVICES OVERIVEW CISCO METRO ETHERNET SERVICES AND SUPPORT In the ever-changing communications market, incumbent service providers are looking for ways to grow revenue. One method is to deploy service

More information

How to Choose the Right Cable Category

How to Choose the Right Cable Category How to Choose the Right Cable Category Why do I need a different category of cable? Not too long ago, when local area networks were being designed, each work area outlet typically consisted of one Category

More information

10GBASE-T for Broad 10 Gigabit Adoption in the Data Center

10GBASE-T for Broad 10 Gigabit Adoption in the Data Center WHITE PAPER 10GBASE-T Ethernet Network Connectivity April 2012 10GBASE-T for Broad 10 Gigabit Adoption in the Data Center Responding to the increasing use of virtualization and unified networking by scaling

More information

Office Rents map EUROPE, MIDDLE EAST AND AFRICA. Accelerating success.

Office Rents map EUROPE, MIDDLE EAST AND AFRICA. Accelerating success. Office Rents map EUROPE, MIDDLE EAST AND AFRICA Accelerating success. FINLAND EMEA Office Rents H2 212 NORWAY Oslo 38.3 5.4% 7.% 295, SWEDEN Stockholm 44.7 4.5% 3.% 5, Tallinn 13.4 44,2 21. 5.25% 1.% 12,

More information

SunGard Best Practice Guide

SunGard Best Practice Guide SunGard Best Practice Guide What Number Should I Use? www.intercalleurope.com Information Hotline 0871 7000 170 +44 (0)1452 546742 conferencing@intercalleurope.com Reservations 0870 043 4167 +44 (0)1452

More information

E-Seminar. Financial Management Internet Business Solution Seminar

E-Seminar. Financial Management Internet Business Solution Seminar E-Seminar Financial Management Internet Business Solution Seminar Financial Management Internet Business Solution Seminar 3 Welcome 4 Objectives 5 Financial Management 6 Financial Management Defined 7

More information

GLOBAL DATA CENTER INVESTMENT 2013

GLOBAL DATA CENTER INVESTMENT 2013 2013 CENSUS REPORT: Global Data Center Investment 2013 GLOBAL DATA CENTER INVESTMENT 2013 2013 - Healthy Growth in Data Center Investment Globally Globally, the data center industry has continued to maintain

More information

Implementing Fast Ethernet

Implementing Fast Ethernet Implementing Fast Ethernet R The Next Generation of Ethernet Fast Ethernet (also known as IEEE 802.3u or 100BASE-T) is quickly becoming the successor to Ethernet as the network topology of choice. Fast

More information

The big pay turnaround: Eurozone recovering, emerging markets falter in 2015

The big pay turnaround: Eurozone recovering, emerging markets falter in 2015 The big pay turnaround: Eurozone recovering, emerging markets falter in 2015 Global salary rises up compared to last year But workers in key emerging markets will experience real wage cuts Increase in

More information

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network Application Brief Test Challenges: Designing heating and air conditioning (HVAC) systems Collecting data on a remotely located

More information

OSMIUM HIGH DENSITY FIBER OPTIC CHASSIS

OSMIUM HIGH DENSITY FIBER OPTIC CHASSIS OSMIUM HIGH DENSITY FIBER OPTIC CHASSIS OSMIUM HIGH DENSITY FIBER OPTIC CHASSIS The Osmium high density fiber optic chassis is based upon a modular and scalable system composed of 19 unloaded chassis,

More information

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure Data Center Optimization: Component Choice and Innovative Design Combine to Allow the Creation of an Enabling Infrastructure Data Center Spaces Data Center Spaces as Defined by the TIA 942 Standard Source:

More information

Triple-play subscriptions to rocket to 400 mil.

Triple-play subscriptions to rocket to 400 mil. Triple-play criptions to rocket to 400 mil. Global triple-play criptions will reach 400 million by 2017; up by nearly 300 million on the end-2011 total and up by 380 million on the 2007 total, according

More information

Guide. Axis Webinar User Guide

Guide. Axis Webinar User Guide Guide Axis Webinar User Guide Introduction Joining an Axis Webinar is a quick and easy way to gain additional knowledge about more than just new products, and technology. These webinars allow attendees

More information

Cisco Blended Agent: Bringing Call Blending Capability to Your Enterprise

Cisco Blended Agent: Bringing Call Blending Capability to Your Enterprise DATA SHEET Cisco Blended Agent: Bringing Call Blending Capability to Your Enterprise Cisco ICM software has traditionally enabled companies to distribute inbound service volume to a variety of termination

More information

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware for CAT 6A Connecting Hardware Written by: Antoine Pelletier Engineer, Global Cabling Products Intertek www.intertek-etlsemko.com 1-800-WORLDLAB Introduction The telecommunication industry recently achieved

More information

Guide. Axis Webinar. User guide

Guide. Axis Webinar. User guide Guide Axis Webinar User guide Table of contents 1. Introduction 3 2. Preparations 3 2.1 Joining the visual part 3 2.2 Joining the conference call 3 2.3 Providing feedback and asking questions during a

More information

Sulfuric Acid 2013 World Market Outlook and Forecast up to 2017

Sulfuric Acid 2013 World Market Outlook and Forecast up to 2017 Brochure More information from http://www.researchandmarkets.com/reports/2547547/ Sulfuric Acid 2013 World Market Outlook and Forecast up to 2017 Description: Sulfuric Acid 2013 World Market Outlook and

More information

PANDUIT Physical Layer Infrastructure Management. EMC Smarts Integration Module

PANDUIT Physical Layer Infrastructure Management. EMC Smarts Integration Module PANDUIT Physical Layer Infrastructure Management EMC Smarts Integration Module SM About PANDUIT A World Class Developer PANDUIT is a world class developer and provider of leading edge solutions that help

More information

DSV Air & Sea, Inc. Aerospace Sector. DSV Air & Sea, Inc. Aerospace

DSV Air & Sea, Inc. Aerospace Sector. DSV Air & Sea, Inc. Aerospace DSV Air & Sea, Inc. Aerospace Sector DSV Air & Sea, Inc. Aerospace Introduction to DSV DSV is a global supplier of transport and logistics services. We have offices in more than 70 countries and an international

More information

Updated development of global greenhouse gas emissions 2013

Updated development of global greenhouse gas emissions 2013 Updated development of global greenhouse gas emissions 2013 Hans-Joachim Ziesing Low Carbon Markets and the Legacy of Nuclear Power 19 th REFORM Group Meeting, Schloss Leopoldskron, Salzburg September

More information

CISCO AIRONET POWER INJECTOR

CISCO AIRONET POWER INJECTOR DATA SHEET CISCO AIRONET POWER INJECTOR Cisco Aironet Power Injector products increase the deployment flexibility of Cisco Aironet wireless access points and bridges by providing an alternative powering

More information

Optimizing Infrastructure Support For Storage Area Networks

Optimizing Infrastructure Support For Storage Area Networks Optimizing Infrastructure Support For Storage Area Networks December 2008 Optimizing infrastructure support for Storage Area Networks Mission critical IT systems increasingly rely on the ability to handle

More information

World Consumer Income and Expenditure Patterns

World Consumer Income and Expenditure Patterns World Consumer Income and Expenditure Patterns 2014 14th edi tion Euromonitor International Ltd. 60-61 Britton Street, EC1M 5UX TableTypeID: 30010; ITtableID: 22914 Income Algeria Income Algeria Income

More information

IBM Global Services. IBM Maintenance Services managed maintenance solution for Cisco products

IBM Global Services. IBM Maintenance Services managed maintenance solution for Cisco products IBM Maintenance Services managed maintenance solution for Cisco products agenda The challenges of business connection The IBM/Cisco strategic alliance Introducing IBM Maintenance Services managed maintenance

More information

Intelligent Infrastructure Management System (IIMS)

Intelligent Infrastructure Management System (IIMS) Intelligent Infrastructure Management System (IIMS) Introduction The requirements of today s rapidly growing and changing enterprise infrastructures are no longer fully satisfied by traditional process-based

More information

Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network

Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network WP4270 Issued: June 2011 Authors: Carl Roberts and Merrion Edwards Introduction

More information

T R A V E L A N D A C C O M M O D A T I O N E X P E N S E S 2 0 1 4

T R A V E L A N D A C C O M M O D A T I O N E X P E N S E S 2 0 1 4 13/01/2015 www.bdo.lu T R A V E L A N D A C C O M M O D A T I O N E X P E N S E S 2 0 1 4 In Luxembourg the travel expenses for business trips are reimbursed either based on actual expenses or based on

More information

IP Networking and the Advantages of consolidation

IP Networking and the Advantages of consolidation WHITE PAPER Extending the Benefits of Storage Area Networks across IP Networks Introduction The phenomenal growth of Internet business and data-intensive e-business applications over the past few years

More information

It looks like your regular telephone.

It looks like your regular telephone. It looks like your regular telephone. But it s a lot better. CISCO PHONE SYSTEM SOLUTIONS FOR SMALL AND MEDIUM BUSINESSES Between the increased productivity and administrative savings we ve experienced,

More information

BEST EXECUTION POLICY

BEST EXECUTION POLICY BEST EXECUTION POLICY In Prague on 9 th December 2015 TABLE OF CONTENT 1. Introductory provisions 2. Markets where the Company executes customer's instructions 3. Instructions 4. Strategy for executing

More information

Cisco Conference Connection

Cisco Conference Connection Data Sheet Cisco Conference Connection Cisco IP Communications a comprehensive system of powerful, enterprise-class solutions including IP telephony, unified communications, IP video/audio conferencing,

More information

10GBASE T for Broad 10_Gigabit Adoption in the Data Center

10GBASE T for Broad 10_Gigabit Adoption in the Data Center 10GBASE T for Broad 10_Gigabit Adoption in the Data Center Contributors Carl G. Hansen, Intel Carrie Higbie, Siemon Yinglin (Frank) Yang, Commscope, Inc 1 Table of Contents 10Gigabit Ethernet: Drivers

More information

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair Presentation; Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair 5 th April 2010 Paul Mathews MInstSMM, CCNA, MIEEE Global Channel Manager Media Types Physical Layer Cabling;

More information

THE CISCO CRM COMMUNICATIONS CONNECTOR GIVES EMPLOYEES SECURE, RELIABLE, AND CONVENIENT ACCESS TO CUSTOMER INFORMATION

THE CISCO CRM COMMUNICATIONS CONNECTOR GIVES EMPLOYEES SECURE, RELIABLE, AND CONVENIENT ACCESS TO CUSTOMER INFORMATION CUSTOMER SUCCESS STORY THE CISCO CRM COMMUNICATIONS CONNECTOR GIVES EMPLOYEES SECURE, RELIABLE, AND CONVENIENT ACCESS TO CUSTOMER INFORMATION EXECUTIVE SUMMARY CUSTOMER NAME Coleman Technologies INDUSTRY

More information

The ABC of Direct Attach Cables

The ABC of Direct Attach Cables The ABC of Direct Attach Cables Thomas Ko, RCDD Product Manager TE Connectivity Network Speed and Technology 10/40/100 Gbps the transition is occurring right now What are Customers Saying about their 10/40/100

More information

Report on Government Information Requests

Report on Government Information Requests Report on Government Information July 1 - December 31, 2015 Apple takes our commitment to protecting your data very seriously and we work incredibly hard to deliver the most secure hardware, software and

More information

Report on Government Information Requests

Report on Government Information Requests Report on Government Information January 1 - June 30, 2015 Apple takes our commitment to protecting your data very seriously and we work incredibly hard to deliver the most secure hardware, software and

More information

BT Connect Networks that think

BT Connect Networks that think Networks that think We run network services for 3,000 organisations in 197 countries/territories BT Ethernet Connect update, December 2011 BT Ethernet Connect Quick recap What s new/changed What s coming

More information

10/40/100 MIGRATION IN DATA CENTERS The Three P s : Path, Polarity and Pins

10/40/100 MIGRATION IN DATA CENTERS The Three P s : Path, Polarity and Pins 0/40/00 MIGRTION IN DT CENTERS ENTERPRISE NETWORK SOLUTIONS /// WHITE PPER 0/40/00 Migration in Data Centers FORWRD-LOOKING DT CENTER DESIGNERS ND MNGERS RELIZE THT, NOW THT THE STNDRDS RE LRGELY DEFINED,

More information

GfK PURCHASING POWER INTERNATIONAL

GfK PURCHASING POWER INTERNATIONAL GfK PURCHASING POWER INTERNATIONAL 1 Agenda 1. Europe 3 2. Americas 45 3. Asia & Near East 54 4. Afrika 66 5. Australia 68 6. Overview of countries and available levels 70 2 2 EUROPE 4 GfK

More information

How To Connect A Cisco Aironet 350 Series Wireless Bridge To A Network With A Wireless Bridge

How To Connect A Cisco Aironet 350 Series Wireless Bridge To A Network With A Wireless Bridge Data Sheet Cisco Fixed Wireless Solution The Cisco Aironet 350 Series enables high-speed long-range outdoor links between buildings and is ideal for installations subject to plenum rating and harsh environments.

More information

Global Economic Briefing: Global Inflation

Global Economic Briefing: Global Inflation Global Economic Briefing: Global Inflation August 7, Dr. Edward Yardeni -97-7 eyardeni@ Debbie Johnson -- djohnson@ Mali Quintana -- aquintana@ Please visit our sites at www. blog. thinking outside the

More information

Cisco IOS Public-Key Infrastructure: Deployment Benefits and Features

Cisco IOS Public-Key Infrastructure: Deployment Benefits and Features Data Sheet Cisco IOS Public-Key Infrastructure: Deployment Benefits and Features Introduction to Public Key Infrastructure Public Key Infrastructure (PKI) offers a scalable method of securing networks,

More information

with Component Rating A Simple Perspective

with Component Rating A Simple Perspective Cat-6A UTP and Shielded with Component Rating A Simple Perspective Asef Baddar RCDD, DCD Sr. Technical Manager Leviton Middle East Category Specifications Agenda Terminology International & North America

More information

100BASE-SX Fast Ethernet:

100BASE-SX Fast Ethernet: 100BASE-SX Fast Ethernet: A Cost Effective Migration Path for Fiber in the Horizontal Prepared by the Fiber Optics LAN Section of the Telecommunications Industry Association February 2000 2000 TIA Fiber

More information

Schedule 2e. Additional terms for Ethernet services

Schedule 2e. Additional terms for Ethernet services 1. SERVICE DESCRIPTION The Interoute Ethernet Clear and Ethernet Flex Services offer Circuits carrying telecommunications traffic between Network Termination Points on the Interoute Ethernet Network and/

More information

Cisco CNS NetFlow Collection Engine Version 5.0

Cisco CNS NetFlow Collection Engine Version 5.0 Data Sheet Cisco CNS NetFlow Collection Engine Version 5.0 Cisco CNS consists of software and appliance-based applications, which support scalable network deployment, configuration, service assurance monitoring,

More information

Cisco WebEx Social Compatibility Guide

Cisco WebEx Social Compatibility Guide Cisco WebEx Social Compatibility Guide This document provides compatibility information for supported components and applications for Cisco WebEx Social 3.4.2, 3.4, 3.3, 3.1, and 3.0. Note: Due to different

More information

Simplifying Data Center Network Architecture: Collapsing the Tiers

Simplifying Data Center Network Architecture: Collapsing the Tiers Simplifying Data Center Network Architecture: Collapsing the Tiers Abstract: This paper outlines some of the impacts of the adoption of virtualization and blade switches and how Extreme Networks can address

More information

Data Center Market Trends

Data Center Market Trends Data Center Market Trends Business and Consumer Applications are Driving Data Demand Data centers support enterprise applications Providing business critical information to the connected workforce with

More information