Position switches FR series

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Position switches FR series"

Transcription

1 Position switches FR series Selection diagram 01 A A2 A4 05 A5 external rubber gasket external rubber gasket external rubber gasket external rubber gasket external rubber gasket stainless steel round rod square rod fiber glass rod porcelain roller ACTUATORS WITH RESET 01-W 02-W 05-W 0-W -W 0-W 1-W 51-W CONTACT BLOCKS slow action slow action slow action snap action snap action snap action slow action slow action and slow action NO+ NC +1NC 2x() slow action slow action slow action slow action slow action snap action independent closer slow action electronic CONDUIT ENTRY product option Threaded conduit entry PG 1,5 (standard) A PG 11 M1 M16x1,5 M2 Mx1,5 M 1/2 NPT With assembled cable gland for Ø 6 to Ø mm K21 cables range for Ø to Ø mm K25 cables range With M plastic connector assembled and wired K0 K45 4 poles from bottom 8 poles from bottom With M metal connector assembled and wired K K60 8 poles from bottom 4 poles from bottom accessory sold separately 2/ General Catalog 1-

2 0 A stainless steel stainless steel stainless steel external Ø 11 mm Ø mm rope switches Ø mm Ø mm Ø mm rubber gasket roller roller for signalling roller roller roller adjustable lever safety adjustable lever without actuator LOOSE ACTUATORS See page 2/51 52-W 54-W 56-W 5-W 8-W without actuator Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. article options FR 2-1WXGM2K0 Housing FR Suffix polymer housing, one conduit entry 5, snap action 6, slow action, slow action Actuators 01 short plunger 02 roller lever 05 offset roller lever no suffix (standard) with stainless steel roller: - Ø mm for actuator A4, - Ø mm for actuators A2, 02, A5, 05 - Ø mm for actuators 0, 1, 51, 52, 54, 55, 56, 5 with Ø 5 mm polymer roller (see special loose actuators on page 2/52) with Ø mm rubber roller (see special loose actuators on page 2/52) with Ø mm overhanging rubber roller (see special loose actuators on page 2/52) General Catalog 1- Contacts type G Reset hooking W W4 For the complete list of all combinations, please contact our technical office. Threaded conduit entry silver contacts (standard) silver contacts gold plated 1 µm (contact block 2 excluded) External metallic parts X zinc plated steel (standard) stainless steel without reset (standard) simultaneous reset Preinstalled cable gland or connectors simultaneous reset with increased force no cable gland or connector (standard) K21 assembled cable gland (see conduit entry page 2/) K0 4 poles M assembled plastic connector (see conduit entry page 2/) PG 1,5 (standard) A PG 11 M1 M2 M M16x1,5 Mx1,5 1/2 NPT 2/42

3 Position switches FR series Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin and with double insulation One threaded conduit entry Protection degree: IP6 according to EN with cable gland having equal or higher protection degree General data Ambient temperature: from -25 C to +80 C Version for operation in ambient temperature from - C to +80 C on request Max actuation frequency: 600 operations cycles 1 /hour Mechanical endurance: million operations cycles 1 Assembling position: any Driving torque for installation: see pages /1-/ One operation cycle means two movements, one to close and one to open contacts, as foreseen by EN standard. Main data Polymer housing, one conduit entry Protection degree IP6 1 contact blocks available 48 actuators available External stainless steel parts versions M assembled connector versions Silver contacts gold plated versions Markings and quality marks: Approval IMQ: EG6 Approval UL: 18 Approval CCC: Approval EZU: Approval GOST: POCC IT.AB24.B045 Cross section of the conductors (flexible copper wire), 21,,, 4: min. 1 x 0,4 mm 2 (1 x AWG ) max. 2 x 1,5 mm 2 (2 x AWG 16) 5, 6,, 9,, 11,, 1,,, 16, 18: min. 1 x 0,5 mm 2 (1 x AWG ) max. 2 x 2,5 mm 2 (2 x AWG ) Contact block 2: min. 1 x 0,5 mm 2 (1 x AWG ) max. 2 x 1,5 mm 2 (2 x AWG 16) In conformity with standards: IEC , EN , EN , EN 04, IEC 604-1, EN 604-1, EN 88, EN ISO 0-1, EN ISO 0-2, IEC 60529, EN 60529, NFC 6-1, VDE , VDE 011. Approvals: IEC , UL 8, GB In conformity with requirements requested by: Low Voltage Directive 06/95/EC, Machinery Directive 06/42/EC and Electromagnetic Compatibility 04/8/EC. Positive contact opening in conformity with standards: IEC , EN , VDE Installation for safety applications: Use only switches marked with the symbol. The safety circuit must always be connected with the NC contacts (normally closed contacts: 11-, 21- or 1-2) as stated in the standard EN , encl. K, par. 2. The switch must be actuated with at least up to the positive opening travel shown in the travels diagrams on page /6. The switch must be actuated at least with the positive opening force, shown in brackets, underneath each article, near the value of the min. force. If not expressly indicated in this chapter, for the right installation and the correct utilization of all articles see requirements indicated from page /1 to page /. Electrical data Utilization categories without connector with 4 poles M connector Thermal current (Ith): Rated insulation voltage (Ui): A 0 Vac 600 Vdc 0 Vac 0 Vdc (contact blocks 2, 11,,, 21,,, 4) Rated impulse withstand voltage (U imp ): 6 kv 4 kv (contact blocks, 21,,, 4) Conditional shot circuit current: 00 A according to EN Protection against short circuits: fuse A 0 V type am Pollution degree: Thermal current (Ith): 4 A Rated insulation voltage (Ui): 2 Vac 00 Vdc Protection against short circuits: fuse 4 A 0 V type gg Pollution degree: Alternate current: AC (...60 Hz) Ue (V) Ie (A) Direct current: DC1 Ue (V) Ie (A) 6 1,1 0,4 Alternate current: AC (...60 Hz) Ue (V) Ie (A) Direct current: DC1 Ue (V) Ie (A) 4 1,1 0,4 with 8 poles M connector Thermal current (Ith): 2 A Rated insulation voltage (Ui): 0 Vac 6 Vdc Protection against short circuits: fuse 2 A 0 V type gg Pollution degree: Alternate current: AC (...60 Hz) Ue (V) 24 Ie (A) 2 Direct current: DC1 Ue (V) 24 Ie (A) 2 2/4 General Catalog 1-

4 Data type approved by IMQ, CCC and EZU Rated insulation voltage (Ui): 0 Vac 0 Vac (for contact blocks 2, 11,,, 21,,, 4) Thermal current (Ith): A Protection against short circuits: fuse A 0 V type am Rated impulse withstand voltage (U imp ): 6 kv 4 kv (for contact blocks, 21,,, 4) Protection degree: IP6 MV terminals (screw clamps) Pollution degree Utilization category: AC Operation voltage (Ue): 0 Vac ( Hz) Operation current (Ie): A Forms of the contact element: Za, Zb, Za+Za, Y+Y, X+X, Y+Y+X, Y+Y+Y, Y+X+X Positive opening of contacts on contact block 5, 6,, 9, 11, 1,, 16, 18,, 21,,, 4 Data type approved by UL Utilization categories Q00 (69 VA, 5-2 Vdc) A600 ( VA, Vac) Data of the housing type 1, 4X indoor use only,, 1 For all contact blocks except 2 and use 60 or 5 C copper (Cu) conductor and wire size No. - AWG. Terminal tightening torque of,1 lb in (0.8 Nm). For contact blocks 2 and use 60 or 5 C copper (Cu) conductor and wire size No. AWG. Terminal tightening torque of lb in (1.4 Nm). In conformity with standard: UL 8 Please contact our technical service for the list of approved products. In conformity with standards: EN , EN A1:09, fundamental requirements of the Low Voltage Directive 06/95/CE. Please contact our technical service for the list of approved products. Adjustable levers In switches with revolving lever it is possible to adjust the lever with steps for the whole 60 range. The positive movement transmission is always guaranteed thanks to the particular geometrical coupling between the lever and the revolving shaft as prescribed for safety applications by the German standard BG-GS- ET-. Overturning levers It s possible to fasten the lever on switches on straight or reverse side, maintaining the positive coupling. In this way it is possible to obtain two different work plans of the lever. Rotating heads In all switches, it is possible to rotate the head in 90 steps. Working operation of contact block 16 with independent contacts The contact block 16 has two NC contacts, both with positive opening activated independently according to the lever turning direction. Lever turned to left Lever not turned Lever turned to right Contacts diagram Contacts diagram Contacts diagram General Catalog 1-2/44

5 Position switches FR series LO = slow action LS = slow action LV = slow action and LI = slow action independent LA = slow action closer = electronic LO L 1 1 LV LS L L FR 1 FR 601 FR 01 FR 901 FR 01 FR 11 FR 11 FR 1 FR 11 FR 01 FR 1801 FR 01 FR 21 FR 21 FR 1 FR Ø 8 1NO+ NC +1NC 2x() page /5 - type 4 page /6 - group FR 5A1 FR 6A1 FR A1 FR 9A1 FR A1 FR 11A1 FR A1 FR 1A1 FR A1 FR A1 FR 18A1 FR A1 FR 21A1 FR A1 FR A1 Ø Ø 8 1NO+ NC +1NC page /5 - type 4 6 N (25 N ) page /6 - group FR 2 FR 602 FR 02 FR 902 FR 02 FR FR FR 2 FR FR 02 FR 1802 FR 02 FR 22 FR FR 2 FR E2 1NO+ NC +1NC 5.5 2x() page /5 - type 6 N (25 N ) page /6 - group FR 5A2 FR 6A2 FR A2 FR 9A2 FR A2 FR 11A2 FR A2 FR 1A2 FR A2 FR A2 FR 18A2 FR A2 FR 21A2 FR A2 FR 2A2 FR A2 1NO+ NC +1NC 5.5 2x() page /5 - type 4, N (25 N ) page /6 - group 2 With Ø mm stainless steel roller on request (29-5) (1-2) 11 LO L 1 1 LV LS L L FR 5A4 FR 6A4 FR A4 FR 9A4 FR A4 FR 11A4 FR A4 FR 1A4 FR A4 FR A4 FR 18A4 FR A4 FR 21A4 FR A4 FR A4 1NO+ NC +1NC page /5 - type 5 6 N (25 N ) page /6 - group FR 5 FR 605 FR 05 FR 905 FR 05 FR FR FR 5 FR 15 FR 05 FR 1805 FR 05 FR 25 FR 25 FR 5 FR E5.4 1NO+ NC +1NC 2x() page /5 - type 6 N (25 N ) page /6 - group FR 5A5 FR 6A5 FR A5 FR 9A5 FR A5 FR 11A5 FR A5 FR 1A5 FR A5 FR A5 FR 18A5 FR A5 1NO+ FR 21A5 NC FR A5 +1NC FR 2A5 2x() FR A5 page /5 - type 4, N (25 N ) page /6 - group FR FR 60 FR 0 FR 90 FR 0 FR 1 FR 1 FR FR 1 FR 0 FR 180 FR 0 FR 2 FR 2 FR FR E 1NO+ NC +1NC 2x() page /5 - type 4 N (25 N ) page /6 - group Accessories See page 6/1 All measures in the drawings are in mm 2/45 General Catalog 1-

6 Fixed only by threaded head in vertical position LO = slow action LS = slow action LV = slow action and LI = slow action independent LA = slow action closer = electronic LO L 1 1 LV LS L L (29-5) (1-2) FR 5A FR 6A FR A FR 9A FR A FR 11A FR A FR 1A FR A FR A FR 18A FR A 1NO+ FR 21A NC FR A +1NC FR 2A 2x() FR A page /5 - type N (25 N ) page /6 - group FR 8 FR 608 FR 08 FR 908 FR 08 FR 18 FR 18 FR 8 FR 18 FR 08 FR 1808 FR 08 FR FR FR 8 FR E8 Ø 1NO+ NC +1NC 2x() page /5 - type 4 page /6 - group FR 5 FR 6 FR FR 9 FR FR 11 FR FR 1 FR FR FR 18 FR FR 21 FR FR 2 FR Mx1 1NO+ NC +1NC 2x() page /5 - type 4 page /6 - group 1 Ø FR 5 FR 6 FR FR 9 FR FR 11 FR FR 1 FR FR FR 18 FR FR 21 FR FR 2 FR M 18x1 24 1NO+ NC +1NC 2x() page /5 - type 4 page /6 - group 1 Ø 8 4 Ø 11 mm polymer roller Ø mm stainless steel roller M 18x R LO L 1 1 LV LS L L FR 51 FR 61 FR 1 FR 91 FR 1 FR 111 FR 1 FR 11 FR 1 FR 1 FR 181 FR 1 FR 211 FR 1 FR 21 FR 1 1NO+ NC +1NC 2x() page /5 - type 2 page /6 - group 1 FR 5 FR 6 FR FR 9 FR FR 11 FR FR 1 FR FR FR 18 FR FR 21 FR FR 2 FR 1NO+ NC +1NC 2x() page /5 - type 4 page /6 - group 1 FR 5 FR 6 FR FR 9 FR FR 11 FR FR 1 FR FR FR 18 FR FR 21 FR FR 2 FR 1NO+ NC +1NC 2x() page /5 - type 2 page /6 - group 1 FR 5-1 FR 6-1 FR -1 FR 9-1 FR -1 FR 11-1 FR -1 FR 1-1 FR -1 FR -1 FR 18-1 FR -1 FR 21-1 FR -1 FR 2-1 FR -1 1NO+ NC +1NC 2x() page /5 - type 2 page /6 - group 1 Items with code on the green background are available in stock General Catalog 1-2/46

7 2B Position switches FR series Fixed only by threaded head in vertical position LO = slow action LS = slow action LV = slow action and LI = slow action independent LA = slow action closer = electronic LO L 1 1 LV LS L L 92.5 FR 516 FR 616 FR 16 FR 916 FR 16 FR 1116 FR 16 FR 116 FR 16 FR 16 FR 1816 FR 16 FR 2116 FR 16 FR 216 FR 16 1NO+ NC +1NC 2x() page /5 - type 2 page /6 - group FR 51 FR 61 FR 1 FR 91 FR 1 FR 111 FR 1 FR 11 FR 1 FR 1 FR 181 FR 1 FR 211 FR 1 FR 21 FR 1.8 1NO+ NC +1NC 2x() page /5 - type 2 page /6 - group 1 1 Mx1.5 4 FR FR FR FR 18 FR FR 21 FR FR 2 FR Ø 1NO+ NC +1NC 2x() 1 m/s 0,0 Nm page /6 - group FR 521 FR 21 FR 11 FR 1821 FR 21 FR 21 FR 21 FR 1 FR 21 1NO+ NC +1NC 2x() 1 m/s 0,0 Nm page /6 - group 4 Ø 1.2 With Ø mm stainless steel roller on request Other rollers available. See page 2/52 x mm square rod LO L 1 1 LV LS 1I L L FR 525 FR 25 FR FR 1825 FR 25 FR 25 FR 25 FR 5 FR 25 1NO+ NC +1NC 2x() 1 m/s 0, Nm page /6 - group 4 Ø FR FR 60 FR 0 FR 90 FR 0 FR 1 FR 0 FR FR 1 FR 0 FR 160 FR 180 FR 0 FR 2 FR 0 FR 20 FR E NO+ NC +1NC 2x() page /5 - type 1 page /6 - group FR 51 FR 61 FR 1 FR 91 FR 1 FR 111 FR 1 FR 11 FR 1 FR 1 FR 161 FR 181 FR 1 1NO+ FR 211 NC FR 1 +1NC FR 21 2x() FR 1 page /5 - type 1 page /6 - group FR 5 FR 6 FR FR 9 FR FR 11 FR FR 1 FR FR FR 16 FR 18 FR FR 21 FR FR 2 FR xx NO+ NC +1NC 5 2x() 1,5 m/s 0,06 Nm page /6 - group 5 Accessories See page 6/1 2/4 General Catalog 1-

8 Ø mm stainless steel round rod Other rollers available. See page 2/52 Other rollers available. See page 2/52 LO = slow action LS = slow action LV = slow action and LI = slow action independent LA = slow action closer = electronic LO L 1 1 LV LS 1I L L FR 54 FR 64 FR 4 FR 94 FR 4 FR 1 FR 4 FR FR 4 FR 4 FR 164 FR 184 FR 4 FR 2 FR 4 FR 24 FR 4 Ø. 1NO+ NC +1NC x() 1,5 m/s 0,06 Nm page /6 - group FR 5 FR 6 FR FR 9 FR FR 10 FR FR 0 FR FR FR 16 FR 18 FR FR 20 FR FR 2 FR E0 Øx NO+ NC +1NC 5 2x() 1,5 m/s 0,06 Nm page /6 - group FR 551 FR 651 FR 51 FR 951 FR 51 FR 11 FR 51 FR 1 FR 51 FR 51 FR 1651 FR 1851 FR 51 FR 21 FR 51 FR 251 FR.6 1NO+ NC +1NC 54 2x() page /5 - type 1 page /6 - group FR 552 FR 652 FR 52 FR 952 FR 52 FR FR 52 FR 2 FR 52 FR 52 FR 1652 FR 1852 FR 52 1NO+ FR 22 NC FR 52 +1NC FR 252 2x() FR E2 page /5 - type 1 page /6 - group 5 Porcelain roller Other rollers available. See page 2/52 Other rollers available. See page 2/52 Other rollers available. See page 2/52 LO L 1 1 LV LS 1I L L Ø 9 FR 55-E0V9 FR 65-E0V9 FR 5-E0V9 FR 95-E0V9 FR 5-E0V9 FR 5-E0V9 FR -E0V9 FR 5-E0V9 FR 5-E0V9 FR 185-E0V9 FR 5-E0V9 FR 2-E0V9 FR 5-E0V9 FR 25-E0 FR E-E0V NO+ NC +1NC 2x() 0,5 m/s 0,0 Nm (0,25 Nm ) page /6 - group FR 554 FR 654 FR 54 FR 954 FR 54 FR FR 54 FR 4 FR 54 FR 54 FR 1654 FR 1854 FR 54 FR 24 FR 54 FR 254 FR E NO+ NC +1NC 2x() page /5 - type 1 page /6 - group FR 555 FR 655 FR 55 FR 955 FR 55 FR 15 FR 55 FR 5 FR 55 FR 55 FR 1655 FR 1855 FR 55 1NO+ FR 25 NC FR 55 +1NC FR 255 2x() FR E5 page /5 - type 1 page /6 - group FR 556 FR 656 FR 56 FR 956 FR 56 FR 16 FR 56 FR 6 FR 56 FR 56 FR 1656 FR 1856 FR 56 FR 26 FR 56 FR 256 FR E6 29 1NO+ NC +1NC 2x() page /5 - type 1 page /6 - group 5 Items with code on the green background are available in stock Positive opening only with lever adjusted on the max. See page 2/51. General Catalog 1-2/48

9 Position switches FR series Other rollers available. See page 2/52 Fiber glass rod Rope switches for signalling LO = slow action LS = slow action LV = slow action and LI = slow action independent LA = slow action closer = electronic LO L 1 1 LV LS 1I L L FR 55 FR 65 FR 5 FR 95 FR 5 FR 1 FR 5 FR FR 5 FR 5 FR 165 FR 185 FR 5 FR 2 FR 5 FR 25 FR E 1NO+ NC +1NC 2x() page /5 - type 1 page /6 - group X.2 Ø6x0 6.5 FR 569 FR 669 FR 69 FR 969 FR 69 FR 1169 FR 69 FR 169 FR 69 FR 69 FR 1669 FR 1869 FR 69 1NO+ FR 2169 NC FR 69 +1NC FR 269 2x() FR 69 1,5 m/s 0,06 Nm page /6 - group FR 56 FR 66 FR 6 FR 96 FR 6 FR 116 FR 6 FR 16 FR 6 FR 6 FR 186 FR 6 +1NC FR 216 NO FR 6 1NO+ FR 26 2x() 0,5 m/s initial N - final N page /6 - group Position switches FR series with reset Pizzato Elettrica has developed a reset device code W to make perfectly simultaneous the actuator and the contact block tripping. The new device is a block inserted between the switch body and the head, and could be rotated independently from this last one. This new device has following advantages: The reset device integrate in almost all standard actuation head with snap action are no more necessary because the tripping movement is made by the reset device itself The reset device can be rotated independently from the head for the maximum flexibility during the assembling Two driving forces: standard and increased for applications with vibrations Mechanical endurance: 1 million operations cycles. 2(29-5) (1-2) Ø L L L FR 601-W FR 901-W FR 01-W FR 01-W FR 21-W FR 21-W FR 1-W 1NO+ NC +1NC + page /5 - type 4 4,5 N (25 N ) page / - group 1 FR 602-W FR 902-W FR 02-W FR 02-W FR 22-W FR -W FR 2-W 1NO+ NC +1NC + page /5 - type 4 N (25 N ) page / - group 2 FR 605-W FR 905-W FR 05-W FR 05-W FR 25-W FR 25-W FR 5-W 1NO+ NC +1NC + page /5 - type 4 N (25 N ) page / - group 2 FR 60-W FR 90-W FR 0-W FR 0-W FR 2-W FR 2-W FR -W 1NO+ NC +1NC + page /5 - type 2,5 N (25 N ) page / - group Accessories See page 6/1 2/49 General Catalog 1-

10 With Ø mm stainless steel roller on request Other rollers available. See page 2/52 Other rollers available. See page 2/ L L L FR 6-W FR 9-W FR -W FR -W FR 21-W FR -W FR 2-W 4 1NO+ NC +1NC + page /5 - type 2 4,5 N (25 N ) page / - group FR 60-W FR 90-W FR 0-W FR 0-W FR 2-W FR 0-W FR 20-W 2 1NO+ NC +1NC + page /5 - type 1 0,0 Nm (0,25 Nm ) page / - group FR 61-W FR 91-W FR 1-W FR 1-W FR 211-W FR 1-W FR 21-W 2 1NO+ NC +1NC + page /5 - type 1 0,0 Nm (0,25 Nm ) page / - group 4.5 FR 651-W FR 951-W FR 51-W FR 51-W FR 21-W FR 51-W FR 251-W NO+ NC +1NC + page /5 - type 1 0,0 Nm (0,25 Nm ) page / - group 4 Other rollers available. See page 2/52 Other rollers available. See page 2/52 Other rollers available. See page 2/52 Other rollers available. See page 2/ L L L FR 652-W FR 952-W FR 52-W FR 52-W FR 22-W FR 52-W FR 252-W NO+ NC +1NC + page /5 - type 1 0,0 Nm (0,25 Nm ) page / - group FR 654-W FR 954-W FR 54-W FR 54-W FR 24-W FR 54-W FR 254-W NO+ NC +1NC + page /5 - type 1 0,0 Nm (0,25 Nm ) page / - group FR 656-W FR 956-W FR 56-W FR 56-W FR 26-W FR 56-W FR 256-W 2 1NO+ NC +1NC + page /5 - type 1 0,0 Nm (0,25 Nm ) page / - group FR 65-W FR 95-W FR 5-W FR 5-W FR 2-W FR 5-W FR 25-W 2.1 1NO+ NC +1NC + page /5 - type 1 0,0 Nm (0,25 Nm ) page / - group 4 Increased actuating force The switch can be supplied with an increased actuating force (option W4); ideal for applications with vibrations. Actuator Force 01,,, 16 N 02, 05 6 N 0,5 N ,08 Nm Items with code on the green background are available in stock General Catalog 1-2/

11 Position switches FR series Position switches with revolving lever without actuator LO = slow action LS = slow action LV = slow action and LI = slow action independent LA = slow action closer = electronic LO L 1 1 LV LS 1I L L FR 58 FR 68 FR 8 FR 98 FR 8 FR 118 FR 1 FR 18 FR 8 FR 8 FR 168 FR 188 FR 8 1NO+ FR 218 NC FR 8 +1NC FR 2x() FR 8 page /6 - group 5 With manual reset knob.2 FR 68-W FR 98-W FR 8-W FR 8-W FR 218-W FR 8-W FR -W 0.9 1NO+ NC +1NC + 0,0 Nm (0,25 Nm ) page / - group 4 IMPORTANT For safety applications: join only switches and actuators marked with symbol. For more information about safety applications see page /1. Loose actuators IMPORTANT: These loose actuators can be used with items of series FR, FM, FX, FZ, FK only. Polymer roller Ø 18 mm Polymer roller Ø 18 mm Adjustable square rod xx5 mm Flexible rod actuator Adjustable round rod Ø x5 mm Polymer roller Ø mm xx Ø6x Ø Ø x VF LE0 VF L VF LE VF LE4 VF LE VF LE51 Polymer roller Ø mm Porcelain roller Polymer roller Ø mm Adjustable actuator with polymer roller Adjustable safety actuator with polymer roller Polymer roller Ø mm Adjustable fiber glass rod VF LE52 VF LE5 (2) VF LE54 VF LE55 VF LE56 VF LE5 VF LE69 - Only orders for multiple quantities of the packs are accepted. - Actuator VF LE55 suits to safety applications only if adjusted to its max length, as you can see in figure beside. If you need an adjustable lever for safety applications, use the adjustable safety lever VF LE56. - (2) The position switch obtained by assembling the switch FR 8 (e.g. FR 58, FR 68) with the actuator VF LE5 will not present the same travel diagrams and actuating forces as the position switch FR 5-E0V9 (e.g. FR 55-E0V9, FR 65-E0V9...). - The actuator cannot be oriented to inside direction because it will mechanically interfere with the switch head. 9 Accessories See page 6/1 2/51 General Catalog 1-

12 Special loose actuators IMPORTANT: These loose actuators can be used with items of series FR, FM, FX, FZ, FK only. Ø mm stainless steel rollers VF L-1 VF LE51-1 VF LE52-1 VF LE54-1 VF LE55-1 VF LE56-1 VF LE5-1 Ø 5 mm polymer rollers VF L-2 VF LE51-2 VF LE52-2 VF LE54-2 VF LE55-2 VF LE56-2 VF LE5-2 Ø mm rubber rollers VF L-R5 VF LE51-R5 VF LE52-R5 VF LE54-R5 VF LE55-R5 VF LE56-R5 VF LE5-R5 Ø mm rubber rollers Ø mm overhanging rubber rollers VF LE51- VF LE52- VF LE54- VF LE55- VF LE56- VF LE VF LE55-4 VF LE56-4 Items with code on the green background are available in stock General Catalog 1-2/52

Limit switches 5. Osiswitch Classic. Page 5/80. Page 5/80. Page 5/82. Page 5/82

Limit switches 5. Osiswitch Classic. Page 5/80. Page 5/80. Page 5/82. Page 5/82 Presentation, general characteristics switches Metal, type XCK J Conforming to CENELEC EN 41 b XCK J fixed body with 1 cable entry v With head for linear movement (plunger) Page /8 v With head for rotary

More information

E100 series. Overview POSITION SWITCHES - E100/E200/E300/E400

E100 series. Overview POSITION SWITCHES - E100/E200/E300/E400 POSITION SWITCHES POSITION SWITCHES - E1/E2/E/E4 Overview Position switches are electromechanical devices which are particularly useful in automated installations, such as the automatic detection of the

More information

Safety hinge switches HP-HC series

Safety hinge switches HP-HC series Safety hinge switches HP-HC series pplication field Pizzato Elettrica widens its own range of products making a new series of safety switches hinge-shaped, where safety and style are melted in one single

More information

Limit Switch D4B- N. Ordering Information. Model Number Legend D4B- N-

Limit Switch D4B- N. Ordering Information. Model Number Legend D4B- N- Limit Switch Snap-action or slow-action contact for accurate switching with safe operation via direct drive positive contact opening even with metal deposition between mating contacts. Two sets of contact:

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C .1.1.1 One-side operation ZS 71 range 40 30 ø10 10 53,5(63)* 6 8 18 24 105 33 56 12 22 M20x1,5 52 17,5 42 15 Features To EN 418 / IEC 60947-5-5 Metal enclosure 2 contacts Small body 2 cable entries M20

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry. y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock

More information

Electronic timer CT-TGD.12

Electronic timer CT-TGD.12 2CDC 251 098 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Safe switching and monitoring Solenoid Interlocks

Safe switching and monitoring Solenoid Interlocks Safe switching and monitoring Solenoid Interlocks Solenoid locking switches are used on sliding, hinged and removable guard doors that must be closed and locked for operator safety. It is a two part system

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

General-purpose Limit Switch

General-purpose Limit Switch General-purpose Limit Switch Snap-action or slow-action contact for accurate switching with safe operation via direct drive positive contact opening even with metal deposition between mating contacts.

More information

Safety dialogue solutions

Safety dialogue solutions General Presentation Emergency stop trip wire switches Emergency stop trip wire switches are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics Amphenol C 16-1 / C 16-3 Circular Circular Connectors Connectors Amphenol-Tuchel Electronics General information We reserve the right to change the design due to improvement in quality, development or

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Cam switches. CQ Series

Cam switches. CQ Series Cam switches CQ Series CQ Series Overview The range of cam switches CQ series includes ratings from to A with insulation voltage of 69V. According to the latest industrial application standards, CQ series

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Common Features of Electromechanical Switches

Common Features of Electromechanical Switches Common Features of Electromechanical Switches Switching systems Switching elements lie at the heart of all electromechanical switching devices and must correspond to the respective application. Essentially

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0. ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)

More information

K1H014MLH cam ammeter switch - 4 circuits A - screw mounting

K1H014MLH cam ammeter switch - 4 circuits A - screw mounting Characteristics cam ammeter switch - 4 circuits - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters Characteristics voltage control relay RM17-U - range 65..260 V AC Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main Range of

More information

Connect - Contact - Control. S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.

Connect - Contact - Control. S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26. Connect - Contact - Control Snap-action switches S86, S6 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D6.en Snap-action switches S86 Series Dual changeover

More information

Cam switches. CQ Series

Cam switches. CQ Series Cam switches CQ Series CQ Series Overview The range of cam switches CQ series includes ratings from to A with insulation voltage of 69V. According to the latest industrial application standards, CQ series

More information

RM4TR32 three-phase network control relay RM4-T - range V

RM4TR32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 300..430 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

RE7TL11BU on-delay timing relay s - 24 V AC DC - 1OC

RE7TL11BU on-delay timing relay s - 24 V AC DC - 1OC Characteristics on-delay timing relay - 0.05..1 s - 24 V AC DC - 1OC Main Commercial Status Range of product Product or component type Component name Time delay type Time delay range [Us] rated supply

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Duct Humidity & Temperature Transmitter

Duct Humidity & Temperature Transmitter SDC-HT Duct Humidity & Transmitter Features Replaceable sensor element Humidity and temperature measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Machine Safety Switches

Machine Safety Switches Machine Switches SI-LS31H Series 31 mm Limit-Switch-Style with Hinged Lever Actuators Features Limit switch design (EN 50047) For use on doors or flaps Positive opening safety contacts (IEC 60947-5-1)

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

SWITCHGEAR. 4G cam switches

SWITCHGEAR. 4G cam switches SWITCHGEAR 164 4G cam switches ENERGY SAFELY SWITCHED 165 SWITCHGEAR 166 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate

n Choice of equipment SP 58 Index of protection: IP 2X - IP 2XC - under front plate SP fuse carriers with protected terminals SP fuse carriers with protected terminals www.klinkmann.com n Choice of equipment Maximum cartridge rating Type Rated current 400 V± 0 V± 690 V± gg am gg am gg

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact

Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact Data sheet Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact The CT-VWE is an electronic time relay with Impulse-ON function. It is from the CT-E range. The CT-E range is the economic range

More information

E2K-C. Long-distance Capacitive Proximity Sensor. Ordering Information. Sensors. Accessories (Order Separately) Mounting Brackets.

E2K-C. Long-distance Capacitive Proximity Sensor. Ordering Information. Sensors. Accessories (Order Separately) Mounting Brackets. Long-distance Capacitive Proximity Sensor Capacitive Proximity Sensor with Adjustable Sensitivity Detects both metallic and non-metallic objects (glass, lumber, water, oil, plastic, etc.) without direct

More information

Long-distance capacitive proximity sensor. Ordering Information EB-74. Sensors. Accessories (Order Separately) Mounting Brackets. Unshielded.

Long-distance capacitive proximity sensor. Ordering Information EB-74. Sensors. Accessories (Order Separately) Mounting Brackets. Unshielded. Long-distance capacitive proximity sensor Capacitive Proximity Sensor with Adjustable Sensitivity Detects both metallic and non-metallic objects (glass, lumber, water, oil, plastic, etc.) without direct

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

TECHNICAL DATA SHEET LS-1 Limit Switch

TECHNICAL DATA SHEET LS-1 Limit Switch TECHNICAL DATA SHEET LS-1 Limit Switch 2 Otter Court, Raymond, New Hampshire 03077 Tel. (603) 895-4761 FAX (603) 895-6785 www.geminivalve.com DESCRIPTION The LS-1 limit switch easily mounted to any Gemini

More information

AZM /11ZPKE 24 VAC/DC

AZM /11ZPKE 24 VAC/DC Print - Create PDF - Create EXCEL file - Hide system components 21.04.2011-14:12:20h Datasheet - AZM 415-11/11ZPKE 24 VAC/DC Solenoid interlock / AZM 415 Metal enclosure Interlock with protection against

More information

Measuring and monitoring relays CM-MSS (4), CM-MSS (5) Thermistor motor protection relays

Measuring and monitoring relays CM-MSS (4), CM-MSS (5) Thermistor motor protection relays Data sheet Measuring and monitoring relays CM-MSS (4), Thermistor motor protection relays The devices CM-MSS (4) and (5) are used to monitor the overload of motors by the wiring temperature. The motors

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor output Connection

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Schneider Electric. TeSys Vacuum Contactors. June. Building a New Electric World

Schneider Electric. TeSys Vacuum Contactors. June. Building a New Electric World TeSys Vacuum Contactors June 2002 Building a New Electric World Selection guide, characteristics Contactors 5 Selection guide Contactor size LC1-V160 LC1-V320 LC1-V610 For utilisation category AC-3 Maximum

More information

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

ISSUE 3. Installation Instructions for the GLL Series Limit Switch WARNING. Sensing and Control

ISSUE 3. Installation Instructions for the GLL Series Limit Switch WARNING. Sensing and Control Installation Instructions for the GLL Series Limit Switch ISSUE 3 50012101 PERSONAL INJURY Where possible, install these switches with the conduit opening pointed down to drain moisture away from switch.

More information

Electronic Circuit Breaker ESS20-0...

Electronic Circuit Breaker ESS20-0... Description Electronic circuit breaker type ESS0-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

Datasheet Electronic TERMSERIES Relays and Solid-State Relays

Datasheet Electronic TERMSERIES Relays and Solid-State Relays Datasheet Electronic TERMSERIES Relays and Solid-State Relays NEW Weidmuller s TERMSERIES offers innovative pluggable electromechanical and solid-state relays equipped with one or two changeover contacts

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Class 525/580 CONTENTS Description Page General characteristics............................................... 1 Circuit breaker......................................................

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

OLI. Oil level indicator

OLI. Oil level indicator OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

SOURIAU s discrete wire sealing

SOURIAU s discrete wire sealing SOURIAU s discrete wire sealing Description Using proven grommet technology from SOURIAU s extensive knowledge of harsh environments, the UTO & UTS connectors with grommet garantie a discrete wire sealing

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

PHOENIX CONTACT

PHOENIX CONTACT Thermomagnetic circuit breakers CLIPLINE Data sheet 103943_en_04 PHOENIX CONTACT 2010-08-18 1 Description The UT 6-TMC M circuit breaker is a single-position overload circuit breaker with thermomagnetic

More information

Rotary Limit Switch RLS2C

Rotary Limit Switch RLS2C Rotary Limit Switch RLS2C The rotary limit switch is used to control the movement of industrial machinery. It operates as an auxiliary controller of electrical motors through a power interface, such as

More information

SB 175 Connectors - up to 280 Amps

SB 175 Connectors - up to 280 Amps Connectors - up to 280 Amps 2 Pole Wires sizes from #12 (3.3 mm²) to 1/0 (50 mm²) fit in the second to largest connector in the SB series. The 3 pole adds an additional position for power or grounding.

More information

General 1-2-Opto-electronics Safety Switches 4-Emergency

General 1-2-Opto-electronics Safety Switches 4-Emergency General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a

More information

5,5 5,5 20-1 HKM11V HKM11X K1W12D01MC... LA1W12W. 01 1 0,32 5,5 5,5 20 1 - - HKM.. K1W12D10MC... LA1W12W. 10 1 0,32

5,5 5,5 20-1 HKM11V HKM11X K1W12D01MC... LA1W12W. 01 1 0,32 5,5 5,5 20 1 - - HKM.. K1W12D10MC... LA1W12W. 10 1 0,32 Mini Reversing Contactors, Mechanical Interlocked AC Operated Power Ratings Rated Aux. Contacts 2) Type Coil voltage 1) Current Built-in Additional 24 24V 50/60Hz 0 AC2, AC3 on left on right 230 220-230V

More information

Emotron M20 Shaft Power Monitor

Emotron M20 Shaft Power Monitor Emotron M20 Shaft Power Monitor Data Sheet English The M20 provides complete flexibility in terms of the type of protection required for your application. You may select either overload and underload protection

More information

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog 9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G Catalog January 07 Contents Commercial Pressure Switches Pressure Switches b Selection..............................................

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Contact expander modules

Contact expander modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:

More information

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02. Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11

More information

OSYSU Series Outside Screw and Yoke Valve Supervisory Switch

OSYSU Series Outside Screw and Yoke Valve Supervisory Switch Features NEMA 4X* (IP 65) and 6P (IP 67) *Enclosure is 4X. For additional corrosion protection of mounting hardware, use model OSYSU-2 CRH -40º to 140º (-40ºC to 60ºC) operating temperature range Visual

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information