1 DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data

2 Table of Contents 1370 DC Loop Contactors Catalog Number Explanation Contactor Specifications Approximate ounting Dimensions and Weights Lug Kits Catalog Number Explanation Specifications and Selection Dynamic Brake Resistors Catalog Number Explanation Specifications/Selection Approximate ounting Dimensions Wiring Diagrams Reference aterials For additional information, refer to the following publications: Title Publication Available 1370 DC Loop Contactor and Lug Kit Installation Instructions 1370-IN Dynamic Brake Installation Instructions 1370-IN017 For Allen-Bradley Drives Technical Support: Title Allen-Bradley Drives Technical Support Online at or call -F, 7:00a.m. to 6:00p.m. Central STD time: Publication 1370-TD001A-EN-P

3 1370 DC Loop Contactors The Bulletin 1370 DC Contactors are electromagnetically held contactors specially designed to switch the armature current from the DC drive module to a shunt wound DC motor. When used with the appropriate control logic design, these contactors can disconnect the motor armature from the DC drive module when a stop is initiated or in the event of a power failure. Bulletin 1370 DC Contactors have the following features: The contactors feature a top-wired design with all power connections at the top of the contactor. Contacts - The double break silver cadmium oxide contacts are weld resistant for improved reliability. ovable contacts are wedge shaped, while the stationary contacts have a unique fold back design. On contact opening, this fold back design generates a strong magnetic field which quickly throws the arc off the contact surface. The arc is then cooled and extinguished by the surface of the arc chamber. Coil - The contactor coils are hot pressure molded in thermoset epoxy to protect against mechanical damage and harmful environments. The coil shunt plate is designed to retard the magnetic flux until the voltage applied reaches the pick up voltage. Each coil is provided with an exclusive thermal cutout which is designed to open on excessive currents or misapplied voltages. agnet - The high efficiency magnet has a permanent air gap. Pole face wear cannot affect the air gap and cause magnetic sticking due to residual magnetism. Each magnet lamination is phosphate coated to provide ample resistance to corrosion. Catalog Number Explanation Position D C 56 a b c d a Product Type 1370 DC Component D b Type Description Non-Reversing w/db C c Device Description DC Loop Contactor d Current Rating Amps Publication 1370-TD001A-EN-P 3

4 1370 DC Loop Contactors Contactor Specifications Specification Contactor Rating Contact Rating - N.O. (Armature) Voltage: Full Load Steady State Current: Contact Break Current (at 550V DC motor load): All 56A 110A 180A 280A 56A 110A 180A 280A Contact Rating - N.C. (DB Pole) Voltage: All Contact ake Current (at 550V DC resistive load): 56A 110A 180A 280A Auxiliary Contact Rating Voltage: All Continuous Current (all contactors): Contact Break Current (all contactors): Coil Ratings Voltage: All Operate: 550V DC aximum 56A DC aximum 110A DC aximum 180A DC aximum 280A DC aximum 112A DC aximum 220A DC aximum 360A DC aximum 560A DC aximum 550V DC aximum 112A DC aximum 220A DC aximum 360A DC aximum 560A DC aximum 115V AC, 50/60 Hz 10A AC aximum 6A AC aximum 115V AC, 50/60 Hz Pickup: 75% of Nominal (minimum) Dropout: 55% of Nominal (maximum) Breakdown Voltage All 2,100V RS (all electrical elements to ground) Ambient Operating Temperature All 0 to 65 C (32 to 149 F) ounting Orientation All Vertical, Wall ount Contact Termination Line and Load Terminals for N.O. Contacts: Dynamic Braking Terminals for N.C. Contact: 56A 110A 180A 280A 56A 110A 180A 280A x 25/64 screw, 35 Ib.-in. torque 1/4-28 x 3/8 bolt, 45 Ib.-in. torque 5/ x 1/2 bolt, 150 Ib.-in. torque 1/2-13 stud with nut, 400 Ib.-in. torque x 25/64 screw, 35 Ib.-in. torque 1/4-28 x 3/8 bolt, 45 Ib.-in. torque 5/ x 1/2 bolt, 150 Ib.-in. torque 3/8-24 x 5/8 bolt, 240 Ib.-in. torque Coil Termination All Captive Pressure Plate for 2 - #12 AWG wires maximum Contact aterial All Silver Cadmium Oxide Auxiliary Contact All with Captive Pressure Plate for 2 - #14 AWG wires maximum 4 Publication 1370-TD001A-EN-P

5 1370 DC Loop Contactors Approximate ounting Dimensions and Weights E B D A D J C Current Rating Catalog Dimensions - mm (in.) Weight (Cont. Amps) Power Poles Number A B C D E J kg (lbs.) N.O., 1 - N.C DC (3.56) (6.00) (4.47) 35.0 (1.38) (5.50) 12.7 (0.5) 1.4 (3.0) N.O., 1 - N.C DC (3.94) (6.81) (4.63) 40.1 (1.58) (6.31) 12.7 (0.5) 1.8 (4.0) N.O., 1 - N.C DC (6.13) (10.04) (6.09) 69.8 (2.75) (8.66) 16.3 (0.64) 5.4 (12.0) N.O., 1 - N.C DC (7.00) (11.40) (7.66) 80.3 (3.16) (9.84) 20.0 (0.79) 10.0 (22.0) Publication 1370-TD001A-EN-P 5

6 1370 Lug Kits 1370 Lug Kits provide the required lugs to terminate wires on 1370 DC Loop Contactors. When properly installed, the lugs will provide a secure and gas-resistant termination. The Lug Kit contains (2) DB Lugs and (4) Armature Line and Load Lugs. To install the lugs a Thomas & Betts Corporation Compression Tool, model TB6 or TB6S is required. Catalog Number Explanation Position LG 40 a b c a Product Type 1370 DC Component LG b Device Description Lug Kit c Lug Current Rating ax. otor Amps Publication 1370-TD001A-EN-P

7 1370 Lug Kits Specifications and Selection Rated otor DC Contactor Armature Current (1) Rating A DC A DC Armature Conductor Size (2) mm 2 (AWG) DB Conductor Size (3) mm 2 (AWG) Armature Conductor Crimp Lug Hole Size mm (in.) DB Conductor Crimp Lug Hole Size mm (in.) Lug Kit Catalog Number (8) 8.4 (8) 4.8 (0.19) 4.8 (0.19) 1370-LG (6) 8.4 (8) 4.8 (0.19) 4.8 (0.19) 1370-LG (4) 8.4 (8) 4.8 (0.19) 4.8 (0.19) 1370-LG (4) 8.4 (8) 1370-LG (2) 13.3 (6) 1370-LG (1) 13.3 (6) 1370-LG (1/0) 21.2 (4) 1370-LG (1/0) 21.2 (4) 7.9 (0.31) 7.9 (0.31) 1370-LG (2/0) 33.6 (2) 7.9 (0.31) 7.9 (0.31) 1370-LG (3/0) 33.6 (2) 7.9 (0.31) 7.9 (0.31) 1370-LG (4/0) 33.6 (2) 7.9 (0.31) 7.9 (0.31) 1370-LG (250 C) 42.4 (1) 12.7 (0.5) 9.5 (0.38) 1370-LG (300 C) 53.5 (1/0) 12.7 (0.5) 9.5 (0.38) 1370-LG (350 C) 67.4 (2/0) 12.7 (0.5) 9.5 (0.38) 1370-LG (400 C) 67.4 (2/0) 12.7 (0.5) 9.5 (0.38) 1370-LG (500 C) 85.0 (3/0) 12.7 (0.5) 9.5 (0.38) 1370-LG280 (1) The Rated otor Armature Current is taken directly from the motor nameplate or motor data. The current listed in the table (column 1) is the maximum current allowed for the Armature Conductor Size (column 3) and the DC Contactor Rating (column 2). (2) The armature conductors are sized by multiplying the Rated otor Armature Current by 1.25 as provided for in NEC (1987). The DC lug ratings are determined from NEC Table (1987) for copper conductors, insulation temperature rated at 75 C (167 F) at an ambient temperature of 30 C (86 F). If conditions are other than shown in NEC Table then refer to applicable codes. (3) The dynamic braking (DB) conductors are sized as in Note 2, but at half ampacily due to the short time duration of current flow in these conductors, and has been sized to satisfy NEA Standard ICS Dynamic Braking. If the load inertia is larger than that of the motor, calculations must be made to determine correct conductor sizing and DB resistor wattage per NEA Standard ICS Publication 1370-TD001A-EN-P 7

8 1370 Dynamic Brake Resistors Dynamic Braking is an optional control function which facilitates motor stopping under fault conditions or in response to a Coast/DB Stop. Dynamic braking will not provide a holding brake function and is only effective when the motor is rotating. The resistors are sized for an external inertia equal to two or three times the motor inertia and are suitable for three successive DB stops per hour from maximum speed. A drive must be furnished with a normally closed contactor pole in order to use dynamic braking. Catalog Number Explanation Position DB L 65 a b c d a Product Type 1370 DC Component b Device Description DB Dynamic Brake c Voltage Description H 500V DC L 240V DC d Rating HP - 240V DC HP - 500V DC Publication 1370-TD001A-EN-P

9 1370 Dynamic Brake Resistors Specifications/Selection HP Basic Catalog Number Dimension Drawing Connection Diagram Total Watts Ohms Watts Per Resistor 240V DC otor Armature Voltage DBL61 1 A x DBL62 1 A x DBL63 1 A x DBL64 1 A x DBL65 1 A x DBL66 1 A x DBL67 1 A x DBL68 1 A x DBL69 1 A x DBL70 1 A x DBL71 1 A x DBL72 2 B x DBL73 2 B x DBL74 2 B x DBL75 3 C x DBL76 3 C x 3 500V DC otor Armature Voltage DBH63 1 A x DBH64 1 A x DBH65 1 A x DBH66 1 A x DBH67 1 A x DBH68 1 A x DBH69 2 B x DBH70 2 B x DBH71 2 B x DBH72 2 B x DBH73 2 B x DBH74 2 B x DBH75 3 D x DBH76 3 D x DBH77 3 D x DBH78 3 D x DBH79 2 E x 6 Publication 1370-TD001A-EN-P 9

10 1370 Dynamic Brake Resistors Approximate ounting Dimensions Figure 1 Single Resistor 73.0 (2.88) Dimensions are in millimeters (inches) ounting Slot 9.5 (0.38) (9.25) 12.7 (0.50) (10.25) Brass Flat Washer (Qty. 2) 1/4-28 Through Bolt (8.5) Paper Flat Washer (Qty. 6) Hex Nut (Qty. 2) 1/4-28 Lockwasher (Qty. 2) Shipping Size: 279 x 229 x 127 (11 x 9 x 5) Shipping Weight: 1.13 kg (2.5 lbs.) Figure 2 Two Resistors (5.38) Dimensions are in millimeters (inches) ounting Slot 9.5 (0.38) (9.25) 12.7 (0.50) (10.25) Brass Flat Washer (Qty. 4) 1/4-28 Through Bolt (Qty. 2) (8.5) Paper Flat Washer (Qty. 12) Hex Nut (Qty. 4) 1/4-28 Lockwasher (Qty. 4) Figure 3 Three Resistors Shipping Size: 304 x 279 x 178 (12 x 11 x 7) Shipping Weight: 2.04 kg (4.5 lbs.), 1370-DBH79 is 3.40 kg (7.5 lbs.) (7.88) Dimensions are in millimeters (inches) ounting Slot 9.5 (0.38) (9.25) 12.7 (0.50) (10.25) Brass Flat Washer (Qty. 6) 1/4-28 Through Bolt (Qty. 3) (8.5) Paper Flat Washer (Qty. 18) Hex Nut (Qty. 6) 1/4-28 Lockwasher (Qty. 6) Shipping Size: 304 x 279 x 178 (12 x 11 x 7) Shipping Weight: 2.49 kg (5.5 lbs.) 10 Publication 1370-TD001A-EN-P

11 1370 Dynamic Brake Resistors Wiring Diagrams Diagram A Single Resistor DC otor Armature A1+ A2- Diagram D Three Resistors in Series DC otor Armature A1+ A2- DBR1 DBR1 DBR1 DBR2 A1 DB1 DB2 A2 A1 DB1 DB2 A2 Diagram B Two Resistors in Series DC otor Armature A1+ A2- Diagram E Three Groups in Series of Two Resistors in Parallel DC otor Armature A1+ A2- DBR1 DBR2 DBR1 DBR3 DBR5 DBR2 DBR4 DBR6 A1 DB1 DB2 A2 A1 DB1 DB2 A2 Diagram C Three Resistors in Parallel DC otor Armature A1+ A2- DBR1 DBR2 DBR3 A1 DB1 DB2 A2 Publication 1370-TD001A-EN-P 11

12 Trademarks not belonging to Rockwell Automation are property of their respective companies. Power, Control and Information Solutions Headquarters Americas: Rockwell Automation, 1201 South Second Street, ilwaukee, WI USA, Tel: (1) , Fax: (1) Europe/iddle East/Africa: Rockwell Automation, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) , Fax: (32) Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) , Fax: (852) Publication 1370-TD001A-EN-P October, 2008 Copyright 2008 Rockwell Automation, Inc. All rights reserved. Printed in USA.

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives

More information

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit Installation Instructions PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit ATTENTION: The sheet metal cover and mounting screws on the ASIC Board located on the power structure

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold 41-759.3C

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold 41-759.3C 41-759.3C the magnetic core upon energizing of the switch. When the switch closes, the moving contacts bridge two stationary contacts, completing the trip circuit. Also during this operation two fingers

More information

Type MG-6 Multi-Contact Auxiliary Relay

Type MG-6 Multi-Contact Auxiliary Relay Type MG-6 Multi-Contact Auxiliary Relay Instruction Leaflet: 41-753.1 N Effective: August 2008 Supersedes 41-753.1 M, Dated December 1999 ( ) Denotes Change Since Previous Issue Device Number: 94X, Y,

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor. DC Generators DC generators are widely used to produce a DC voltage. The amount of voltage produced depends on a variety of factors. EO 1.5 LIST the three conditions necessary to induce a voltage into

More information

DIRECT CURRENT GENERATORS

DIRECT CURRENT GENERATORS DIRECT CURRENT GENERATORS Revision 12:50 14 Nov 05 INTRODUCTION A generator is a machine that converts mechanical energy into electrical energy by using the principle of magnetic induction. This principle

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN

More information

Armature Actuated Brakes

Armature Actuated Brakes Armature Actuated s P/N 8-078-890-05 effective 05/02/14 Installation and Service Instructions Series AAB Armature Actuated s Sizes 72 through 170 Model Numbers 33[ ]-1, 33[ ]-2, 33[ ]-3, 33[ ]-4, 33[ ]-5

More information

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to

More information

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet ABB Instruction Leaflet 41-161J Effective: May 1997 Supersedes I.L. 41-161H Dated July 1984 ( ) Denotes Change Since Previous Issue Type COQ Negative Sequence Generator Relay (50/60 Hertz)! CAUTION Before

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

PowerFlex Dynamic Braking Resistor Calculator

PowerFlex Dynamic Braking Resistor Calculator Application Technique PowerFlex Dynamic Braking Resistor Calculator Catalog Numbers 20A, 20B, 20F, 20G, 22A, 22B Important User Information Solid-state equipment has operational characteristics differing

More information

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives

Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives User Manual Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives Catalog Number 20A-DG01 Topic Page General Description 2 What Is the DriveGuard Safe Torque Off

More information

SMC -3 Specifications

SMC -3 Specifications Technical Data SMC -3 Specifications Bulletin Number 150 Topic Page Product Overview 2 Standards Compliance and Certifications 2 Features 3 Catalog Number Explanation 4 Wiring Diagrams 6 General Specifications

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Direct Current Motors

Direct Current Motors Direct Current Motors DC MOTORS The DC machine can operate as a generator and as a motor. Chap 5. Electrical Machines by Wildi, 6 e Lecturer: R. Alba-Flores Alfred State College Spring 2008 When a DC machine

More information

BG or BGE Brake Rectifier

BG or BGE Brake Rectifier Brake Voltage Supplied from the otor There are specific instances when the brake voltage can be tapped from the motor's terminal block. The advantage of brake systems wi in this way is when power is applied

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

AZ420 MINIATURE GENERAL PURPOSE RELAY

AZ420 MINIATURE GENERAL PURPOSE RELAY MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available

More information

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear. OVERCURRENT & EARTH FAULT RELAYS Objective: To study the protection of equipment and system by relays in conjunction with switchgear. Theory: The function of a relay is to detect abnormal conditions in

More information

Service and Maintenance. SEW-EURODRIVE Driving the world

Service and Maintenance. SEW-EURODRIVE Driving the world SEW Brakes Service and Maintenance 2 Objectives Upon completion of this session, you will be able to do the following: - Identify the components of an SEW brakemotor - Explain the operation of the SEW

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

5.2. Overview. The better method to install solderless compression connectors on power cable

5.2. Overview. The better method to install solderless compression connectors on power cable 5.2 Overview The better method to install solderless compression connectors on power cable The Thomas & Betts method of installing compression connectors on power cables is designed to provide a high degree

More information

PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B

PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B WHITE PAPER PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS BULLETIN 1497, 1497A, AND 1497B CONTROL CIRCUIT TRANSFORMERS The proper selection of the control circuit transformers is important for suitable

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting

More information

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations 12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling

More information

Lab 8: DC generators: shunt, series, and compounded.

Lab 8: DC generators: shunt, series, and compounded. Lab 8: DC generators: shunt, series, and compounded. Objective: to study the properties of DC generators under no-load and full-load conditions; to learn how to connect these generators; to obtain their

More information

Safetran TYPE ST1 AND ST2 VITAL PLUG-IN RELAYS I-1-1. Relays SIZE 1 AND SIZE 2 READILY MOUNTS TO EXISTING SOCKETS

Safetran TYPE ST1 AND ST2 VITAL PLUG-IN RELAYS I-1-1. Relays SIZE 1 AND SIZE 2 READILY MOUNTS TO EXISTING SOCKETS Safetran I-1-1 TYPE ST1 AND ST2 VITAL PLUG-IN RELAYS SIZE 1 AND SIZE 2 READILY MOUNTS TO EXISTING SOCKETS ALL FERROUS METAL PARTS ARE NICKEL PLATED MEETS OR EXCEEDS APPLICABLE AREMA RECOMMENDED PRACTICES

More information

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................

More information

Drive Software Wizards v2.4

Drive Software Wizards v2.4 Release Notes Drive Software Wizards v2.4 This release notes describes major revision 2, minor revision 4 of drive software wizards for DriveExplorer (v5.02 and higher), DriveTools SP (v4.01 and higher)

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

How To Protect A Motor From Overcurrent

How To Protect A Motor From Overcurrent Phase ailure elays Type PS and PD Class 8430 Catalog 04 CONTENTS Description.....................................................Page Product Description and Definitions......................................

More information

1. The diagram below represents magnetic lines of force within a region of space.

1. The diagram below represents magnetic lines of force within a region of space. 1. The diagram below represents magnetic lines of force within a region of space. 4. In which diagram below is the magnetic flux density at point P greatest? (1) (3) (2) (4) The magnetic field is strongest

More information

General Purpose Relays Types K, R, N, and C

General Purpose Relays Types K, R, N, and C General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in

More information

Relays and Timers Specifications Bulletin Number 700

Relays and Timers Specifications Bulletin Number 700 Technical Data Relays and Timers Specifications Bulletin Number 700 Topic Page General Purpose Relays 2 Timing Relays 41 NEMA Industrial Relays 81 IEC Control Relays 93 Solid State Relays 109 Additional

More information

Aluminium Standard. Technical Data. Included in delivery

Aluminium Standard. Technical Data. Included in delivery luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

V94 BULK TAPE DEGAUSSER

V94 BULK TAPE DEGAUSSER TECHNICAL MANUAL Operating and Maintenance Instructions for V94 BULK TAPE DEGAUSSER V94 BULK TAPE DEGAUSSER TECHNICAL MANUAL Document No. M000208 Production Standard ZZ 009 415 WARNING To help minimise

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

Current Probes. User Manual

Current Probes. User Manual Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

12-Volt Negative Ground Installation Instructions

12-Volt Negative Ground Installation Instructions 12-Volt Negative Ground Installation Instructions For Part Number: 1141, 1164, 1165, 1181 CAUTION!!! Before installing, please read the following important information... 1. The Ignitor is designed for

More information

RAY-MAX Integrated Solar Power Strip

RAY-MAX Integrated Solar Power Strip RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...

More information

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52 Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail

More information

Buck - Boost Transformers

Buck - Boost Transformers Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single

More information

1 POLE - 5A SLIM POWER RELAY

1 POLE - 5A SLIM POWER RELAY POWER RELAY POLE - A SLIM POWER RELAY FTR-MY Series RoHS compliant FEATURES Width mm, height mm,(% smaller than NY series) area mm, super slim, low power, compact and light weight.gr. Nominal power: mw

More information

ELECTROMAGNETIC DISC BRAKES

ELECTROMAGNETIC DISC BRAKES ELECTROMAGNETIC DISC BRAKES TYPE 66E 15/30 52.121 Hand release Lining wear adjustment Torque adjustment 4 holes ø13 DISC SIZE Ø A Braking torque Nm Regulated from (40-100%) Reaction on the shaft N Control

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Rotary Disconnect Switch Specifications

Rotary Disconnect Switch Specifications Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Instructions CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Catalog Number 2100-SD1 Description The Bulletin 2100 smoke detector unit is a 0.5 space factor unit for use in Bulletin

More information

CONSERVER CES INSTRUCTIONS. CETTE NOTICE CONTIENT DES INSTRUCTIONS IMPORTANTES CONCERNANT LA SÉCURITÉ. Positive Connection Point Symbol

CONSERVER CES INSTRUCTIONS. CETTE NOTICE CONTIENT DES INSTRUCTIONS IMPORTANTES CONCERNANT LA SÉCURITÉ. Positive Connection Point Symbol DISCOM 4M Installation and Operation Guide 1.0 Product Overview 2.0 Ratings Table 3.0 Installation 4.0 Operating Instructions 5.0 Warranty and RMA Instructions 6.0 Appendices 7.0 UL1741/CSA Certification

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

A99B Series Temperature Sensors

A99B Series Temperature Sensors FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors

More information

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated? Extra Questions - 2 1. A straight length of wire moves through a uniform magnetic field. The e.m.f. produced across the ends of the wire will be maximum if it moves: a) along the lines of magnetic flux

More information

Drive Technology \ Drive Automation \ System Integration \ Services. DR Motor Common Connection Diagrams

Drive Technology \ Drive Automation \ System Integration \ Services. DR Motor Common Connection Diagrams Drive Technology \ Drive Automation \ System Integration \ Services DR Motor Common Connection Diagrams Edition 06/2010 9PD0058 / US SEW-EURODRIVE Driving the world Table of Contents Overview... 5 Important

More information

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS Braking Resistors for Variable Frequency Drives APPLICATION AC variable frequency drives are commonly used with a general purpose AC induction motor to form a reliable variable speed drive system. For

More information

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION Chromalox Installation, Operation RENEWAL PARTS IDENTIFICATION Portable Industrial Unit Blower Air Type DRA and DIVISION SALES REFERENCE DATE SECTION (Supersedes P-) PF-) NOVEMBER, 00 DRA PF- -0-00 Specifications

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

Power Supply Cables and Connectors

Power Supply Cables and Connectors Power Supply Cables and Connectors Often during the excitement of designing a challenging new system, some of the more mundane engineering aspects get overlooked. This is especially true of connections

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

Instructions for Class W200, W201, Sizes 5 and 6, Three Phase Non-Reversing Magnetic Motor Starters and Contactors

Instructions for Class W200, W201, Sizes 5 and 6, Three Phase Non-Reversing Magnetic Motor Starters and Contactors I.L. 17405 Revision F Instructions for Class W200, W201, Sizes 5 and 6, Three Phase Non-Reversing Magnetic Motor Starters and Contactors RATINGS The maximum horsepower ratings of these motor controllers

More information

36T Series Snap-Action Temperature Controls

36T Series Snap-Action Temperature Controls 36T Series Snap-Action Temperature Controls Snap-Action Temperature Control The 36T series of 1/2 bimetal temperature controls from Therm-O-Disc offers proven reliability in a compact, versatile, cost-effective

More information

Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V

Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Installation Smart-UPS VT and MGE Galaxy 3500 Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Contents Safety... 1 SAVE THESE INSTRUCTIONS...............................

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Model RC Armature-Slot- Insulation Folder

Model RC Armature-Slot- Insulation Folder Model RC Armature-Slot- Insulation Folder 21 Model RC will handle insulation material up to 8 wide between its guides. Creasing rollers are adjustable sideways to make troughs up to 6 wide. A fixed ruler-guide

More information

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC April 00 D Series Standard and Full Featured - Catalogue Number Structure Table -. D Series Catalogue Numbering System Family Type DPR = Standard Relay DPF = Full Featured Relay Contact Configuration =

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES POWER RELAY 1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES RoHS compliant FEATURES Ultra slim type with 5 mm thickness Good for high density mounting Low power consumption and high sensitivity Nominal

More information

STC 3S012-020-A Series Solenoid Valves

STC 3S012-020-A Series Solenoid Valves STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,

More information

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators Product Bulletin Code No. LIT-1201742 Issued February 12, 2015 The M9102 and M9104 Series Actuators are directmount,

More information

INSTRUCTIONS AND PARTS LIST SINGLE GIRDER UNDERHUNG CRANE BRIDGE KITS 1/2 THRU 10 TON HAND GEARED AND MOTOR DRIVEN

INSTRUCTIONS AND PARTS LIST SINGLE GIRDER UNDERHUNG CRANE BRIDGE KITS 1/2 THRU 10 TON HAND GEARED AND MOTOR DRIVEN INSTRUCTIONS AND PARTS LIST SINGLE GIRDER UNDERHUNG CRANE BRIDGE KITS 1/2 THRU 10 TON HAND GEARED AND MOTOR DRIVEN JUNE, 1999 COPYRIGHT 1999, Columbus Mckinnon Corporation PART NO. 113533-71 Page 1 COLUMBUS

More information

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd ACTOM OUTDOOR DISCONNECTORS Single Side Break (SSB) Disconnector 22-132 kv, 800-1 A, 25 ka - 3s Typical bearing assembly. Voltage range 11 kv to 132

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow ingle Conductor Cable Copper heathed Cable heath Currents ingle conductor cables present certain application considerations that do not arise in multiconductor cable installations. These considerations

More information

Owner's/Installation Manual

Owner's/Installation Manual Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH

More information