CJ1 Series PLC. The new, compact CJ1 PLC is now available from stock.

Size: px
Start display at page:

Download "CJ1 Series PLC. The new, compact CJ1 PLC is now available from stock."

Transcription

1 Omron, the company that introduced the industry s first mid-sized PLC, is introducing another product that will redefine PLC classifications. The NEW CJ1 series of controllers is designed to deliver BIG PLC performance from a product the size of the smallest micro controllers on the market, requiring only 60 to 40% of the panel space of traditional mid-size PLCs. With processor speeds and I/O counts exceeding the performance of mid and large rack controllers, the CJ1 allows for compact machines that provide the highest level of control possible. The CJ1 modules are each roughly the size of a deck of playing cards and connect module-to-module using simple locking connectors, eliminating the need for a bulky PLC rack. The lightning quick PC21 bus, designed for Omron s technology-leading mid-sized CS1, provides high-speed communication from the CJ1 CPU to individual modules. The CJ1 also includes the communication options generally associated with larger PLC platforms, leveraging Omron s FINS protocol to transparently tie Ethernet, Controller Link, serial, and device level networks together for data exchange and programming. Program the CJ1 using Omron s CX-Programmer, which support the entire Omron PLC product line. The new, compact CJ1 PLC is now available from stock. A mid-size PLC in a micro-sized package 40% smaller than typical mid-size PLCs: Free up panel space without sacrificing performance! Processor speeds ranging from 80 Nanoseconds to as low as 20 Nanoseconds per basic instruction Ethernet, DeviceNet and Controllerlink communications Industry leading networking: Omron s FINS protocol routes data across networks Control up to 2560 I/O: Typical of the mid-sized PLC category Fully compatible with Omron s CX-Programmer Software Rackless design eliminates the need for a PLC rack, simplifying configuration and lowering system costs Flash Memory Cards up to 48 MB for easy program transfer and data storage

2 Ordering Information Basic Units Description Part Number I/O Program Data memory capacity Points Capacity (steps) CJ1 CPU Unit K 128 Kwords (DM: 32Kwords, EM: 32 Kwords x 3 banks) CJ1G-CPU K 64 Kwords (DM: 32Kwords, EM: 32 Kwords x 1 banks) CJ1G-CPU 44 Power Supply Unit 10 to 240 VAC (with RUN output) output capacity: 5A at 5 VDCCJ1W-PA205R CJ1W-PA205R Flash Memory, 8 Mbytes Flash Memory, 15 Mbytes HMC-EF861 HMC-EF171 Memory Card Flash Memory, 30 Mbytes HMC-EF371 Flash Memory, 48 Mbytes Memory Card Adapter (for PCMCIA slot in PC) HMC-EF571 HMC-AP001 I/0 Control Unit One per CJ-Series CPU Rack when connecting to CJ-Series expansion rack CJ1W-IC101 II/0 Control Unit One required for each CJ-Series expansion rack CJ1W-II101 I/0 Connecting Cable For Connecting The CJ-Series CPU Rack and a CJ-Series Cable Length: 0.3 m CS1W-CN313 expansion rack, or connecting two CJ-Series expansion Cable Length: 0.7 m CS1W-CN713 racks Cable Length: 2 m CS1W-CN223 Cable Length: 3 m Cable Length: 5 m Cable Length: 10 m Cable Length: 22 m CS1W-CN323 CS1W-CN523 CS1W-CN133 CS1W-CN133-B2 CQM1H-PRO01 Programming Console Programming Console Key Sheet: CS1W-KS001-E required (sold separately) CQM1-PRO01 C200H-PRO27 Programming Console For connection with CQM1H-PRO01 (cable length: 0.05 m) CS1W-CN114 Connection Cable For connection with CQM1-PRO01 (cable length: 2.0 m) CS1W-CN224 For connection with C200H-PRO27 (cable length: 6.0 m) CS1W-CN624 Programming Software 1 License Windows-based Note: Can be connected to CX-Programmer programming software peripheral port or RS-232c port on the WS02-CXPC1- OS: Windows 95, 98, NT CPU Unit, or to the RS 232C port on a EV2 Serial Communication Module or via Ethernet and Controller Link networks PC cables for connecting IBM PC/AT or compatible D-sub-9-pin receptacle CS1W-CN118 IBM PC/AT or compatible (for conversion of RS-232c cable to peripheral), cable length: 0.1 m to programming devices IBM PC/AT or compatible D-sub-9-pin receptacle, cable length: 2.0 m CS1W-CN226 to peripheral port IBM PC/AT or compatible D-sub-9-pin receptacle, cable length: 6.0 m CS1W-CN626 Battery (replacement) Lithium Battery 3.6 VDC for CJ Series (included with the CPU Unit) CPM2A-BAT01 End Cover (replacement) For right end of CJ-Series CPU Rack or expansion rack CJ1W-TER01 Note: One included with CPU Unit and I/O Interface Unit 2 For more information, contact an Omron representative at OMRON

3 CJ-Series Basic I/O Units Description Part Number DC Input Modules 16 points, 24 VDC, terminal block CJ1W-ID points, 24 VDC, Fujitsu style connector CJ1W-ID points, 24 VDC, MIL style connector CJ1W-ID points, 24 VDC, Fujitsu style connector CJ1W-ID261 Relay Output Modules 8 points, relay outputs, 2A max. at 250 VAC/ 24VDC, independent contacts CJ1W-OC201 terminal block 16 points, relay outputs, 2A max. at 250 VAC/ 24VDC, terminal block CJ1W-OC211 Transistor Output Modules 16 points, 0.5 A max. at 12 to 24VDC, terminal block CJ1W-OD211 Sinking Outputs 32 points, 0.5 A max. at 12 to 24VDC, Fujitsu style connector CJ1W-OD points, 0.3 A max. at 12 to 24VDC, Fujitsu style connector CJ1W-OD261 Transistor Output Modules 16 points, 24VDC, 0.5 A, terminal block, with load short-circuit protection CJ1W-OD212 Sourcing Outputs 32 points, 24VDC, 0.5 A, terminal block, with load short-circuit protection CJ1W-OD232 CJ-Series Special I/O Units Description Part Number Analog Input Module 8 input points; 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V or 4 to 20 ma CJ1W-AD081 Analog Output Module 4 output points; 1 to 5 v 0 to 5 V, 0 to 10 V, -10 to 10 V or 4 to 20 ma CJ1W-DA041 4 loops, thermocouple input/ NPN output CJ1W-TC001 4 loops, thermocouple input/ PNP output CJ1W-TC002 Temperature Control 2 loops, thermocouple input/ NPN output, with heater disconnection alarm CJ1W-TC003 Modules 2 loops, thermocouple input/ PNP output, with heater disconnection alarm CJ1W-TC004 4 loops, platinum-resistance thermometer input/ NPN output CJ1W-TC101 4 loops, platinum-resistance thermometer input/ PNP output CJ1W-TC102 2 loops, platinum-resistance thermometer input/ NPN output, with heater CJ1W-TC103 disconnection alarm 2 loops, platinum-resistance thermometer input/ PNP output, with heater CJ1W-TC104 disconnection alarm CJ-Series Communication I/O Units Description Part Number Controller Link Module Wired, data links, message communications CJ1W-CLK21 Serial Communications RS-232C x 1 port, RS-422/485 x 1 port CJ1W-SCU41 Module Protocol macros, Host Link, NT Link (1:N) DeviceNet Master Module 2,048 fixed allocation I/O points, 125,000 to 500,000 bps baud rate CJ1W-DRM21 Ethernet Module 10Base-T, FINS communications socket service FTP server, notification CJ1W-ETN11 For more information, contact an Omron representative at OMRON 3

4 Common Model Number CJ1G-CPU45 CJ1G-CPU44 I/O Bits 1280 Program Capacity 60 K Steps 30 K Steps Extended Data Memory 32 K words x 3 banks 32 K words x 1 banks Capacity Current Consumption 0.91 A, 5VDC Control Method Stored Program I/O Control Method Cyclic scan and immediate processing are both possible Programming Ladder Logic Instruction Length 1 to 7 steps per instruction Ladder Instructions Approximately 400 (3-digit function codes) Execution Time Basic Instructions : 0.08 ms min. Special instructions: ).12 ms min. Unit Connection Method No backplane: Units are connected directly to each other using an interlocking connector Mounting Method DIN Rail (Screw mounting is not possible) Number of Connectable Per CPU or expansion rack: 10 Units including basic I/O units. Special I/O units, and CPU bus units Units Number of Expansion 3 total racks possible (an I/O control unit is required on CPU rack and an I/O interface unit is required to Racks on each expansion rack. Number of Tasks 288 (cyclic tasks: 32, interrupt tasks: 256) Interrupt Types Scheduled interrupts, interrupts generated at a time scheduled by the CPU unit s built in timer. Power OFF interrupts: interrupts executed when CPU unit s power is turned OFF CIO I/O Area 1,280 CIO to CIO (80 words from 0000 to 0079) (Core I/O Setting of first rack words can be changed from default (CIO 0000) so that CIO 0000 to 0999 can be used. Area) I/O bits are allocated to Basic I/O Units. Link Area (200 words ): CIO to CIO (words CIO 1000 to CIO 1199) Link bits are used for data links and are allocated to units on Controller Link Systems CPU Bus 6,400 (400 words): CIO to CIO (words CIO 1500 to CIO 1899) Area CPU Bus Unit bits store operating status of CPU Bus Units (25 words per Unit max.) Special I/O 15,360 (960 words): CIO to CIO (words CIO 2000 to CIO 2959) Unit Area Special I/O Unit bits are allocated to Special I/O Units. (10 words per Unit max.) DeviceNet 9,600 (600 words): CIO to CIO (words CIO 3200 to CIO 3799) Area DeviceNet bits are allocated to slaves for DeviceNet Unit remote I/O communications when the master function is used with fixed allocations Internal I/O Area 4,800 (300 words): CIO to CIO (words CIO 1200 to CIO 1499) 37,504 (2344 words): CIO to CIO (words CIO 3800 to CIO 6143) These bits in CIO area are used as work bits in programming to control program execution. They cannot be used for External I/O Work Area 8,192 bits (512 words): W00000 to W51115 (words W000 to W511) Control programs only. (I/O from external I/O terminals is not possible.) Note: When using work bits in programming, use bits in Work Area first before using bits from other areas Holding Area 8,192 bits (512 words): H00000 to H51115 (words W000 to H511) Holding Bits are used to control execution of program, and maintain their ON/OFF status when PC is turned off of operating mode is changed Auxiliary Area Read only: 7,168 bits (448 words): A00000 to A44715 (words A000 to A447) Read/write: 8,192 bits (512 words): A44800 to A95915 (words A448 to A959) Auxiliary bits are allocated to specific functions Temporary Area 16 bits (TR00 to TR15) temporary bits are used to store ON/OFF execution conditions at program branches. Timer Area Counter Area 4,096 T0000 to T4095 (used for timers only) 4,096 C0000 to C4095 (used for counters only) 4 For more information, contact an Omron representative at OMRON

5 Common (continued) DM Area EM Area Index Registers Task Flag Area Trace Memory File Memory 32 K words: D00000 to D32767 Used as a general-purpose data area for reading and writing data in word units (16 bits), Words in DM Area maintain their status when PLC is turned OFF or operating mode is changed. The EM area is divided into banks and addresses that can be set by either of the following methods. Changing current bank using EMBC(281) instruction and setting addresses for current bank. Setting bank numbers and addresses directly EM data can be stored in files by specifying number of first bank. (EM file memory) 32 K words per bank, 3 banks max.: E0_00000 to E2_32767 max. Not available on same CPU units.) Used as a general-purpose data area for reading and writing data in word units (16 bits), Words in EM Area maintain their status when PLC is turned OFF or operating mode is changed. The EM area is divided into banks and addresses that can be set by either of the following methods. Changing current bank using EMBC(281) instruction and setting addresses for current bank. Setting bank numbers and addresses directly EM data can be stored in files by specifying number of first bank. (EM file memory) IR0 to IR15. Store PLC memory addresses for indirect addressing. Index registers can be used independently in each task, One register is 32 bits (2 words) 32 (TK0000 to TK0031). Task Flags are read Only flags that are ON when corresponding task is not executable or in stand-by status words (trace data: 31 bits, 6 words Memory Cards: Compact flash memory cards can be used (MS-DOS format). EM file memory : Part of EM Area can be converted to file memory (MS-DOS format) OMRON Memory Cards with 8-MB, 15-MB, 30-MB, or 48-MB capacities can be used. Function Constant Cycle Time Cycle time Monitoring I/O refreshing I/O memory holding when changing operating modes Load OFF Input time constant setting Mode setting at power-up 1 to 32,000 ms (Unit: 1ms) Possible (Units stops operating is cycle is too long) 1 to 40,000 ms (Unit: 10 ms) Cyclic refreshing, immediate refreshing, refreshing by IORF(097) Depends on ON/OFF status of IOM Hold Bit in Auxiliary Area All Output Units can be turned OFF when CPU Unit is operating in RUN, MONITOR, or PROGRAM mode Time constants can be set for inputs from CJ1 basic I/O Units. The time constant can be increased to reduce influence of noise and chattering or it can be decreased to detect shorter pulses on inputs. Possible (By default, the CPU unit will start in RUN mode if a programming Console is not connected.) Memory Card Automatically reading programs from the Possible Memory Card when the power is turned OFF Program Replacement during PLC operation Possible Format in which data is stored in Memory Card User Program: Program file format PLC Setup and other parameters: Data File format I/O Memory: Data file format (binary format, text format, or CSV format) Functions for when Memory card read/write is User-program instructions supported Program device Host Link computers AR Area bits Filing Memory Card data and EM area can be handled as files Debugging Force-set/ reset, differential monitoring, data tracing (scheduled, each cycle, or when instruction is executed) Online editing User programs can be overwritten in program-block units when CPU unit is in MONITOR mode or PROGRAM mode. This function is not available for block programming areas. With CX-Programmer, more than one block can be edited at the same time Program protection Overwrite protection: Set using DIP switch Copy protection: Password set using peripheral device (such as CX-Programmer/ Programming Console) For more information, contact an Omron representative at OMRON 5

6 Function (continued) Error Check Error log Serial communications Clock Power OFF detection time Power OFF detection delay time Memory protection Sending commands to a Host Link computer Remote programming and monitoring Three-level communications Storing comments in CPU Unit Program check Control output signals Self-diagnostics Other functions User-defined errors (i.e., user can define fatal errors and non-fatal errors) The FPD(269) instruction can be used to check execution time and logic of each programming block Up to 20 errors are stored in error log. Information includes error code, error details, and time the error occurred. Built-in peripheral port: Peripheral Device (including programming Console/CX-Programmer 0 to 25 ms (not-fixed) 0 to 10 ms (user-defined, default: 0 ms) Held Areas: Holding bits, contents of Data Memory and Extended Data Memory, and status of counter Completion Flags and present values. FINS commands can be sent to a computer connected via Host Link System by executing Network Communications Instructions from PC. Host Link communications can be used for remote programming and remote monitoring through a Controller Link System or Ethernet network. Host Link communications can be used remote programming and remote monitoring from devices on networks up to two levels away (Controller Link Network. Ethernet Network, or other network) I/O comments can be stored in CPU Unit in Memory Cards or EM file memory. Program checks are performed at beginning of operation for items such as no END instruction and instruction errors. A Peripheral Device (such as CX-Programmer) can also be used to check programs. RUN output: The contacts will turn ON (close) while CPU Unit is operating. These terminals are provided only on CJ1W-PA205R Power Supply Unit. CPU errors (watchdog timer), I/O bus errors, memory errors, and battery errors. Storage of number of times power has been interrupted, the times of the interrupts, and system operation time (in Auxiliary Area 514words). General Power Supply Unit CJ1W-PA205R Supply voltage 100 to 240 VAC (wide range), 50/60Hz Operating voltage range 85 to 264 VAC, 47 to 63 Hz Power consumption 100 VAC max. Inrush current 15A / 8ms :138VAC max 30A / 8ms :276VAC max Output capacity 5.0 A, 5VDC (including supply to CPU Unit ) 0.8 A, 24VDC Total:25W Output terminal Not provided (service supply) RUN output Contact configuration: SPST-NO Switch capacity: 250 VAC, 2A (resistive load) 250VAC, 0.5A (induction load), 24VDC, 2A Insulation resistance 20M ohm min.,(at 500VDC) between AC external and GR terminals (See Note1) Dielectric strength 2,300 VAC 50/60Hz for 1 min between AC external and GR terminals (See Note1) Leakage current: 10 ma max. 1,000 VAC 50/60Hz for 1 min between DC external and GR terminals (See Note1) Leakage current: 10 ma max. Noise immunity Conforms to IEC , 2kV(power lines) Vibration resistance 10 to 57 Hz, mm amplitude, 57 to 150 Hz, acceleration:9.8m/s 2 in X,Y, and Z directions for 80minutes (according to JIS C0040) (Time coefficient : 8 minutes % coefficient factor 10 = total time 80 min.) Shock resistance 147m/s 2, 3 times each in X,Y, and Z directions (according to JIS C0041) ( Relay Output Units:100m/s 2 ) 6 For more information, contact an Omron representative at OMRON

7 General (continued) Ambient operating temperature Ambient operating humidity Atmosphere Ambient storage temperature Grounding Enclosure Weight CPU Rack Dimensions (mm) Safety measures 0 to 55 C 10% to 90% (with no condensation) Must be free from corrosive gases. -20 to 75 C (excluding battery) Less than 100 ohm Mounted in a panel. All models are each 5 kg max to (W) X 90 (H) X 65 (D) (excluding cable) Conforms to culus, Cl. 1. DIV.2 EC directives Note: 1. Disconnect the Power Supply Unit s LG terminal from the GR terminal when testing insulation and dielectric strength. Basic I/O Units DC Input Units Model Number of Inputs Inputs Voltage Input Current External Connection CJ1W-ID pts. 24VDC 7 ma (24VDC) Terminal Block +10%,-15% CJ1W-ID pts. 24VDC 4.1 ma(24vdc) Fujitsu Connector +10%,-15% CJ1W-ID pts. 24VDC 4.1 ma(24vdc) MIL Connector +10%,-15% CJ1W-ID pts. 24VDC 4.1 ma(24vdc) Fujitsu Connector +10%,-15% Relay Contact Output Units Model Number of Outputs Max. switching capacity Outputs/common External Connection CJ1W-OC201 8 pts. 2A 250VAC Independent Terminal Block 2A 24VDC common 16A/unit CJ1W-OC pts. 2A 250VAC 16 Terminal Block 2A 24VDC 8A/unit Transistor Output Units (Sinking type) Model Number of Outputs Max. switching capacity External Connection CJ1W-OD pts. 12 to 24VDC Terminal Block 0.5 A/pts, 5.0 A/unit CJ1W-OD pts. 12 to 24VDC Fujitsu Connector 0.5 A/pts, 2.0 A/common 4.0A/unit CJ1W-OD pts. 12 to 24VDC Fujitsu Connector 0.3 A/pts, 1.6 A/common 6.4 A/unit Transistor Output Units (Sourcing type) Model Number of Outputs Max. switching capacity External Connection CJ1W-OD pts. 24VDC Terminal Block 0.5 A/pts, 5.0 A/unit Load short protection CJ1W-OD pts. 24VDC MIL Connector 0.5 A/pts, 2.0 A/common 4.0A/unit Load short protection For more information, contact an Omron representative at OMRON 7

8 Special I/O Units Analog Input Units Model Number CJ1W-AD081 Classification Special I/O Unit Number of mountable units 9 Units max. (See Note 1) Isolation Between I/O and PC signals: Photo-coupler (No isolation between individual I/O signals.) External terminals 18 point detachable terminal block (M3 screws) Input Number of analog inputs 8 Input signal range (See Note 2) 1 to 5 V 0 to 5 V 0 to 10 V -10 to 10 V 4 to 20 ma Maximum rated input (for 1 point ) Voltage Input: +/-15V Current Input: +/-30mA Input impedance Voltage Input: 1M ohm min. Current Input: 250 ohm(rated value) Resolution 1/ 4,000 (full scale) Converted output data 16-bit binary data Accuracy (See Note3) 23 +/-2 C Voltage Input: +/-0.2% of full scale Current Input: +/-0.4% of full scale 0 C to 55 C Voltage Input: +/-0.4% of full scale Current Input: +/-0.6% of full scale A/D conversion time (See Note 4) 1.0 ms/point max. Functions Mean value processing Stores the last n data conversions in the buffer, and stores the mean value of the conversion values. Buffer number: n=2,4,8,16,32,64 Peak value holding Stores the maximum conversion value while the Peak Value Hold Bit is ON. Input disconnection detection Detects the disconnection and turns ON the Disconnection Detection Flag. Current consumption 430 ma max. at 5 VDC Weight 140 g max. General specifications Conforms to general specifications for SYSMAC CJ Series. Note: 1. The maximum number of Analog Input Units that can be mounted to one rack varies depending on the current consumption of the other Units mounted to the rack. 2. Input signal ranges can be set for each input. 3. The accuracy is given for full scale. For example, an accuracy of +/-0.2% means a maximum error of +/-8 (BCD). The default setting is adjusted for voltage input. To use current input, perform the offset and gain adjustments as required. 4. A/D conversion time is the time it takes for an analog signal to be stored in memory as converted data after it has been input. It takes at least one cycle before the converted data is read by the CPU Unit. 8 For more information, contact an Omron representative at OMRON

9 Analog Output Units Model Number Classification CJ1W-DA041 Special I/O Unit Number of mountable units 10 Units max. (See Note 1) Isolation External terminals Between I/O and PC signals: Photo-coupler (No isolation between individual I/O signals.) 18 point detachable terminal block (M3 screws) Output Number of analog outputs: 4 Output signal range (See Note 2) 1 to 5 V / 4 to 20 ma 0 to 5 V 0 to 10 V -10 to 10 V Output impedance 0.5 ohm max Max. output current (for 1 point) 12mA Maximum permissible load resistance 600O Resolution 1/4,000 (full scale) Set data 16-bit binary data Accuracy (See Note 3) 23 +/-2 C Voltage output: +/-0.3% of full scale Current output: +/-0.5% of full scale 0 C to 55 C Voltage output: +/-0.5% of full scale Current output: +/-0.8% of full scale D/A conversion time (See Note 4) 1.0 ms/point max. Functions Output hold function Outputs the specified output status (CLR,HOLD, or MAX) under any of the following circumstances. When the Conversion Enable Bit is OFF. In adjustment mode, when a value other than the output number is output during adjustment. When there is an output setting error or a fatal error occurs at the PC. When the CPU Unit is on standby. When the Load is OFF. Current consumption 120 ma max. at 5 VDC External Power consumption More than 200 ma at 24 VDC+10%,-15% Weight 150 g max. General specifications Conforms to general specifications for SYSMAC CJ Series. Note: 1. The maximum number of Analog Output Units that can be mounted to one rack varies depending on the current consumption of the other Units mounted to the rack. 2. Output signal ranges can be set for each output. 3. The accuracy is given for full scale. For example, an accuracy of +/-0.3% means a maximum error of +/-12 (BCD). 4. D/A conversion time is the time required for converting and outputting the PC data. It takes at least one cycle before the data stored in the PC to be read by the Analog Output Unit. For more information, contact an Omron representative at OMRON 9

10 CPU Bus Units Serial Communications Units Model Number CJ1W-SCU41 Classification CPU Bus Unit Serial Port 1 RS-422A / 485 communications Port 2 RS-232C ports Protocol Port 1 Host Link, protocol macro, NT Link, or loopback test can be selected for each port. Port 2 Number of mountable Units A total of up to 16 Units, including all other CPU Bus Units. No restrictions on the mounting location. Current consumption 380 ma + x (See note) Weight 110 g max. General specifications Conforms to general specifications for SYSMAC CJ Series. Note: A current consumption of 150 ma must be added for each Link Adapter that is connected. In the above specifications, x indicates that 150 ma must be added for each port to which a NT-AL001-E Link Adapter is connected to provide the required 5-V power supply. Protocol Host Link Communications mode Half-duplex (Full-duplex for slave-initiated communications) Synchronous mode Start-stop synchronization (asynchronous mode) Baud rate (See Note 1) RS-232C port and RS-422A/485 ports: 1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200 bps Default setting: 9,600 bps Communications distance RS-232C port:15 m max.(see Note 2) (See Note 1) RS-422A/485 port: 500 m max. (The total combined cable length is 500 m max. T-branch lines must be a maximum of 10 m long.) Connection configuration RS-232C port: 1:1 (1:N (N=32 Units max.) is possible using an Converting Link Adapters.) RS-422A/485 port: 1:N (N=32 Units max.) Number of connected Units 32 Units max.(unit numbers 0 to 31;unit number 0 is set for 1:1 connection) Note: 1. Confirm the baud rates and communications distance supported by connected devices. 2. The maximum cable length for RS-232C is 15m. The RS-232C standard, however, does not cover baud rates above 19.2 Kbps. Refer to the manual for the device being connected to confirm support. 10 For more information, contact an Omron representative at OMRON

11 Protocol Macro Function Number of protocols 20 max. Can be created and registered with the Protocol Support Tool Number of sequences 1,000 max (CX-Protocol). Per protocol Number of sequences 60 max. Number of messages 300 max. Number of reception 100 max. matrixes Sequence execution condition Using the CPU Unit s PMCR(260) instruction (specifying the sequence number) Communications mode Half-duplex or full-duplex Synchronous mode Start-stop synchronization (asynchronous mode) Baud rate (See Note 1) RS-232C port and RS-422A/485 ports: 1,200/2,400/4,800/9,600/19,200/38,400 bps Default setting: 9,600 bps Communications distance (See Note 1) RS-232C port:15 m max.(see Note 2) RS-422A/485 port: 500 m max. (The total combined cable length is 500 m max. T-branch lines must be a maximum of 10 m long.) Connection configuration RS-232C port: 1:1 (1:N (N=32 Units ma.) is possible using an Converting Link Adapters.) RS-422A/485 port: 1:N (N=32 Units max.) Number of connected Units 32 Units max.(unit numbers 0 to 31; unit number 0 is set for 1:1 connection) Note: 1. Confirm the baud rates and communications distance supported by connected devices. 2. The maximum cable length for RS-232C is 15m. The RS-232C standard, however, does not cover baud rates above 19.2 Kbps. Refer to the manual for the device being connected to confirm support Controller Link Units Model Number Classification Number of mountable unit Communications method Code Modulation Synchronization Transmission path form Baud rate and maximum transmission distance Media Node connection method Maximum number of nodes Communications functions Number of data link words CJ1W-CLK21 CPU Bus Unit A total of up to 4 units. No restrictions on the mounting location. N:N token bus Manchester code Baseband code Flag synchronization (conforms to HDLC frames) Multi-drop bus The maximum transmission distance varies with the baud rate as follows: 2 Mbps: 500 m 1 Mbps: 800 m 500 Kbps: 1 km Specified shielded twisted-pair cable Number of signal lines: 2, shield line: 1 Connected to a terminal block 32 nodes Data links and message service Transmission area per node: 1,000 words (2,000 bytes) max. Data link area in one C200HX/HG/HE, CVM1, CV-series, or CM1H-series PC (send/receive): 8,000 words (16,000 bytes) max. Data link area in one CS/CJ-series PC (send/receive): 12,000 words (24,000 bytes) max. Date link area in one IBM PC/AT or compatible (transmission/reception): 32,000 words (64,000 bytes) max. Number of data link words in one network (total transmission): 32,000 words (64,000 bytes) max. For more information, contact an Omron representative at OMRON 11

12 Controller Link Units (continued) Data link areas Message length RAS functions Error control Current consumption Weight General specifications Bit areas (IR,AR,LR,CIO), data memory (DM), and extended data memory (EM) 2,012 bytes max. (including the header) Polling node backup function Self-diagnosis function (hardware checking at startup) Echo-back test and broadcast test (using the FINS command) Watchdog timer Error log function Manchester code check CRC check (CCITT X 16 +X 12 +X 5 +1) 350 ma 110 g Conforms to general specifications for SYSMAC CJ Series. Ethernet Units Model Number Type Unit classification Number of mountable unit CJ1W-ETN11 10Base-T CPU Bus Unit Transfer Media access method CSMA/CD specifications Modulation Base-band Transmission paths Baud rate A total of up to 4 units. No restrictions on the mounting location. Star 10 Mbps Transmission media Unshielded twisted-pair (UTP) cable Transmission Segment 100 m max. distance length Current consumption 380 ma Weight 100 g max. General specifications Conforms to general specifications for SYSMAC CJ Series. 12 For more information, contact an Omron representative at OMRON

13 Current Consumption Power Supply Unit Max. Current Consumption Max. Total Power Consumption 5V group 24V group (supply to Relay Output) CJ1W-PA205R 5.0 A 0.8 A 25 W Note: This table shows the maximum currents and power that can be supplied by Power Supply Units on CPU Racks and Expansion Racks. Current Consumption Tables 5VDC Voltage Group Name Model 5V-Consumption CPU Units CJ1G-CPU A (These values include (See Note.) current consumption by a CJ1G-CPU A Programming Console or CX-Programmer.) (See Note) Expansion Unit CJ1W-IC A CJ1W-II A End cover CJ1W-TER01 Including CPU Unit or Expansion Unit Note: Add 0.15 A per port when the NT-AL001-E is connected. Basic I/O Units Category Name Model 5V-Consumption Input Units DC Input Units CJ1W-ID A CJ1W-ID A CJ1W-ID A CJ1W-ID A Output Units Transistor Output Units CJ1W-OD A CJ1W-OD A CJ1W-OD A CJ1W-OD A CJ1W-OD A Output Units Relay Output Units CJ1W-OC A CJ1W-OC A Special I/O Units Category Name Model 5V-Consumption Special I/O Units Analog Input Unit CJ1W-AD A Analog output Unit CJ1W-DA A Temperature Control Units CJ1W-TC A Communication I/O Units Category Name Model 5V-Consumption CPU Bus Units Controller Link Units CJ1W-CLK A Serial Communications Units CJ1W-SCU A (See Note) Ethernet Units CJ1W-ETN A DeviceNet Unit CJ1W-DRM A Note: Add 0.15 A per port when the NT-AL001-E is connected. 24VDC Voltage Group Category Name Model Consumption Output Units Relay Output Units CJ1W-OC A ( A X ON bits) CJ1W-OC A ( A X ON bits) For more information, contact an Omron representative at OMRON 13

14 Comparison to CS-series PCs The CS-series and CJ-series PCs use the same architecture and are basically the same in terms of program structure (tasks), instruction system, I/O memory, and other functionality. They do differ, however in that the CJ-series PCs have a different Unit structure, support different Units, do not support Inner Boards, have different Expansion Racks, have a different I/O allocation method, etc. These differences are outlined in the following table. CJ1 CS-Series Dimensions: Height x width 90 X 65 mm 130 X 123 mm Unit connections Connected to each other via connectors. Mounted to Backplanes. End Cover connected to right end to indicate end of Rack. Maximum I/O capacity 1,280 I/O points 5,120 I/O points Maximum program capacity 60 K steps 250 K steps Maximum data memory 128 K words 448 K words (DM and EM Areas combined) Instructions systems I/O memory PC Setup Cyclic task functionality Interrupt tasks Power OFF interrupt task, schedule Power OFF interrupt task, schedule interrupt tasks (no I/O interrupt or interrupt tasks, I/O interrupt, and external interrupt tasks) external interrupt tasks) Programming Devices : CX-Programmer and Programming Consoles Instruction execution Basic instructions 0.08 µs min µs min. time Special instructions 0.12 µs min 0.12 µs min Overhead time 0.5 ms 0.5 ms Mounting DIN Track (not mountable with screws) Screws or DIN Track Inner Boards Not supported. Supported. Special I/O Units and CPU Bus Units Structure of allocations is the same. Special I/O Units: 96 Units max.( restrictions on mounting positions) CPU Rack mounting positions 10 Units max. 3,5,8,or10 slots (11 Units or more will cause an error) Expansion Rack mounting positions 10 Units max. 2,3,5,8,or10 slots (11 Units or more will cause an error) Expansion Racks One I/O Control Unit required on CPU Either C200H or CS-series Expansion Rack and one I/O Interface Unit I/O Racks can be connected without an required on each Expansion Rack. I/O Control Unit or I/O Interface Units. Maximum number of Expansion Racks 3 7 Maximum total cable length to Expansion Racks 12 m Maximum number of Units SYSBUS Remote I/O Not supported Supported. File Memory (Memory Cards or EM Area) Trace Memory I/O allocation Automatic allocation from right to let Automatic allocation from right to left starting at Unit closest to CPU Unit and starting at Unit closest to CPU Unit and then right to left on Expansion Racks. then right to left on Expansion Racks. 14 For more information, contact an Omron representative at OMRON

15 CJ1 PLC CS-Series PLC Registered I/O tables Support Supported (but operation is possible Supported (must be created from without creating I/O tables from a Programming Device). Programming Device). Modes Either user-set I/O tables or automatic Only user-specified I/O tables ( I/O I/O allocation at startup (no I/O table tables can be verified against actual I/O) verification). The default setting is for Automatic I/O Allocation at Startup. User-set I/O tables can be automatically used by setting and transferring I/O tables (or parameter file). If the I/O tables are deleted from a CPU Unit from the CX-Programmer, Automatic I/O Allocation at Startup will be used again. Allocating unused Possible only by using user-set I/O Always possible.(set by editing I/O words tables (i.e., creating I/O tables with tables on the CX-Programmer and unused words allocated on the transferring them to the CPU Unit.) CX-Programmer and transferring them to the CPU Unit). Discrepancies between registered I/O tables I/O setting error occurs (fatal error). I/O verify error occurs (non-fatal error). and actual I/O (Without Backplanes and due to the physical connection method, it is essentially impossible for a Unit to fall off or for an empty position to be created. Discrepancies between the registered I/O tables and actual I/O are thus considered to be far more serious.) Setting first word on each Rack Supported. Supported. Startup Mode when a Programming Console is RUN mode PROGRAM mode not mounted and the PC Setup is set to use operating mode specified on the Programming Console Serial communications ports One peripheral port and one RS-232C port. Serial communications Peripheral port : Peripheral bus, Programming Console, Host Link, 1:N NT Link modes RS-232C port : Peripheral bus, Host Link, 1:N NT Link, no protocol Communications commands FINS commands, Host Link commands Index registers Diagnostic functions Error log function Debugging functions (Force-set/reset, differential monitor, data traces, instruction error traces) I/O response time setting functions Battery CPM2A-BAT01 CS1W-BAT01 Size Comparison For more information, contact an Omron representative at OMRON 15

16 Dimensions Power Supply Unit CJ1W-PA205R CPU Units CJ1G-CPU44/CPU45 8 Points - 16 Points I/O AD/DA and Temperature Control Unit CJ1W-ID211/OC201/OC211/ OD211/OD212 AD081/DA041/TC I/O Control Unit CJ1W-IC101 I/O Interface Unit CJ1W-II Points I/O Units CJ1W-1D261/OD Points I/O Units CJ1W-ID231/ID232/OD231/OD232 Serial Communication Controller Link, Ethernet and DeviceNet Units CJ1W-SCU41/CLK21/ETN11/DRM21 CJ1W-ID231/OD231 CJ1W-ID232/OD For more information, contact an Omron representative at OMRON

17 Overall CJ1 Dimensions (Dimensions: mm) A=80 (Power Supply Unit) + 62 (CPU Unit) + 20xn + 31Xm (End Cover) n=number of I/O Units (20 mm width) n=number of I/O Units (31 mm width) B=About 82~150mm DIN Track PFP-100N2 PFP-100N PFP-50N C 12 mm 3.3 mm 3.3 mm NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by OMRON ELECTRONICS LLC. OMRON ON-LINE OMRON CANADA, INC. One East Commerce Drive Global Milner Avenue Schaumburg, IL USA - Scarborough, Ontario M1B 5V OMRON Canada Cat. No. DS02PI 08/01 subject to change without notice. Printed in the U.S.A. For more information, contact an Omron representative at OMRON 17

Memory Card (See note.)

Memory Card (See note.) 1H/G-CPU@@H 1-series Programmable Controllers Indicators Inner Board Compartment An Inner Board can be mounted here. Peripheral Port The peripheral port connects Programming Devices, such as a Programming

More information

Smart DeviceNet Remote I/O Terminals

Smart DeviceNet Remote I/O Terminals Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems

More information

CJ1M CPU CLASS I DIV 2. For more information, contact an Omron representative at 1-800-55-OMRON

CJ1M CPU CLASS I DIV 2. For more information, contact an Omron representative at 1-800-55-OMRON Quick, Efficient Communications The CJ1M extends the CJ1 Series to meet the reduced requirements of more compact machine designs: greater functionality, less memory and builtin I/O. The CJ1M provides a

More information

CP1E-E@@D@-@ CP1E-N@@D@-@/NA20D@-@

CP1E-E@@D@-@ CP1E-N@@D@-@/NA20D@-@ New Product SYSMAC CP-series CP1E CPU Units CP1E-E@@D@-@ CP1E-N@@D@-@/NA20D@-@ The CP1E Package PLCs: Economical, Easy to use, and Efficient The E-type Basic CPU Units provide cost performance and easy

More information

Programmable Controller G Series. New. Models

Programmable Controller G Series. New. Models Programmable Controller G Series The IMO G6 is a very compact modular programmable controller offering extremely high performance. It is ideal for all applications from process control to machine control

More information

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP Programmable Safety controllers g9sp G9SP compact Stand-Alone Programmable controller Stand-alone safety controller for small and mid-sized machinery Easy programming for complex safety control Three types

More information

NX safety stand-alone

NX safety stand-alone NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Programmable Controllers

Programmable Controllers Programmable Controllers The Fast, Small, and Flexible CJ1 the World of Machine Control! Expands Concept 2 System Design Guide 17 System Configuration Dimensions 18 22 Fast! Small! Flexible! Versatile

More information

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD Present Value: 8 mm (.32 in) Set Value: 4 mm (.16 in) Nonsignificant

More information

USER S MANUAL. CompoBus/D (DeviceNet) Communications Unit MODEL 3G3MV-PDRT1-SINV. (For SYSDRIVE 3G3MV Multi-function Compact Inverters)

USER S MANUAL. CompoBus/D (DeviceNet) Communications Unit MODEL 3G3MV-PDRT1-SINV. (For SYSDRIVE 3G3MV Multi-function Compact Inverters) Cat. No. I529-E1-1 USER S MANUAL CompoBus/D (DeviceNet) Communications Unit MODEL 3G3MV-PDRT1-SINV (For SYSDRIVE 3G3MV Multi-function Compact Inverters) Thank you for choosing a 3G3MV Multi-function Compact

More information

Programmable Controllers PROGRAMMING MANUAL

Programmable Controllers PROGRAMMING MANUAL Cat. No. W394-E1-05 SYSMAC CS Series CS1G/H-CPU@@-EV1 CS1G/H-CPU@@H CS1D-CPU@@H SYSMAC CJ Series CJ1G-CPU@@ CJ1G/H-CPU@@H CJ1M-CPU@@ Programmable Controllers PROGRAMMING MANUAL SYSMAC CS Series CS1G/H-CPU@@-EV1

More information

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A 6ES7313-5BF03-0AB0 Page 1 Product data sheet 6ES7313-5BF03-0AB0 SIMATIC S7-300, CPU 313C, COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO 1 PT100, 3 FAST COUNTERS (30 KHZ), INTEGRATED 24V DC POWER SUPPLY,

More information

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,

More information

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series. DRT2-series Smart Slave Analog I/O Terminals

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series. DRT2-series Smart Slave Analog I/O Terminals CS-series Net Unit CSM DS_E_5_1 A Net Unit for the CS Series That Boasts Industry-leading Performance and Functions Features Allows control of up to 32,000 points (2,000 words) per master, and ensures

More information

Series Six Plus Programmable Controller

Series Six Plus Programmable Controller Series Six Plus Programmable Controller Gl?K-0147B June 1989 Central Processor Unit 8-Slot Rack 1l-Slot Rack General Description The Central Processor Unit (CPU) for the Series Six Plus Programmable Logic

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Liquid Leakage Sensor Amplifier

Liquid Leakage Sensor Amplifier 9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such

More information

COM. port RS232C RS232C RS232C RS485. Thermocouple input. Part number. Not available. Not available. Available. Not available Available RS485.

COM. port RS232C RS232C RS232C RS485. Thermocouple input. Part number. Not available. Not available. Available. Not available Available RS485. Control Unit New Born! Advanced PC! Timer, Counter, Hour meter, Temperature Controller and PC in a Unit Features. 5-character, -line, -color Display Simple characters and numerical values can be displayed.

More information

CP series CP1L CPU Unit CP1L-EM D -D / CP1L-EL D -D CP1L-M DR-A / CP1L-L DR-A

CP series CP1L CPU Unit CP1L-EM D -D / CP1L-EL D -D CP1L-M DR-A / CP1L-L DR-A CP series CP1 CPU Unit CP1-EM D -D / CP1-E D -D CP1-M DR-A / CP1- DR-A High Performing Programmable Controller with Embedded Ethernet "CP1-EM" and "CP1-E" have an embedded Ethernet port. "CP1-M" and "CP1-"

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Programming Logic controllers

Programming Logic controllers Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,

More information

V350-R34 V350J-R34. npn inputs 245mA@24VDC 275mA@24VDC 275mA@24VDC pnp inputs 170mA@24VDC 200mA@24VDC 200mA@24VDC

V350-R34 V350J-R34. npn inputs 245mA@24VDC 275mA@24VDC 275mA@24VDC pnp inputs 170mA@24VDC 200mA@24VDC 200mA@24VDC Vision OPLC V130-33-R34/V130-J-R34 V350-35-R34/V350-J-R34 V430-J-R34 Technical Specifications Order Information V130-33-R34 PLC with Classic panel, Monochrome display 2.4" V130-J-R34 PLC with Flat panel,

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

M2M/IoT Solutions. www.contec.com

M2M/IoT Solutions. www.contec.com M2M/IoT Solutions www.contec.com M2M/IoT Solutions TM Hardware Highly Reliable M2M Controllers for Various Solutions M2M Controllers Compact design available on DIN rails Low-power design using a CPU tailored

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

Incremental Rotary Encoder E6B2

Incremental Rotary Encoder E6B2 Incremental Rotary Encoder General-Purpose Rotary Encoder Withstands arge Shaft oads Wide variety of supply voltages and output forms Easy-to-adjust zero index (phase Z) with origin indicating function

More information

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise! Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount

More information

Vision OPLC. V350-35-R34/V350-J-R34 Technical Specifications. Technical Specifications

Vision OPLC. V350-35-R34/V350-J-R34 Technical Specifications. Technical Specifications Vision OPLC V350-35-R34/V350-J-R34 Technical Specifications The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2 6ES7315-2AG10-0AB0 Page 1 Product data sheet 6ES7315-2AG10-0AB0 SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2. INTERFACE DP-MASTER/SLAVE

More information

USER S MANUAL. Programmable Controller Option Board MODELS 3G3MV-P10CDT-E AND 3G3MV-P10CDT3-E (For SYSDRIVE 3G3MV Multi-function Compact Inverters)

USER S MANUAL. Programmable Controller Option Board MODELS 3G3MV-P10CDT-E AND 3G3MV-P10CDT3-E (For SYSDRIVE 3G3MV Multi-function Compact Inverters) Cat. No. I01E-EN-01 OMRON USER S MANUAL Programmable Controller Option Board MODELS 3G3MV-P10CDT-E AND 3G3MV-P10CDT3-E (For SYSDRIVE 3G3MV Multi-function Compact Inverters) 3G3MV-P10CDT PLC Option Unit

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

CQM1-SF200/CS1W-SF200

CQM1-SF200/CS1W-SF200 Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit

More information

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

Cat.No. W352 E1 3 SYSMAC CPM2A. Programmable Controllers OPERATION MANUAL

Cat.No. W352 E1 3 SYSMAC CPM2A. Programmable Controllers OPERATION MANUAL Cat.No. W352 E1 3 SYSMAC CPM2A Programmable Controllers OPERATION MANUAL CPM2A Programmable Controllers Operation Manual Revised December 1999 Notice: OMRON products are manufactured for use according

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

EZ-View Network Communications Guide www.cszindustrial.com

EZ-View Network Communications Guide www.cszindustrial.com Network Communications Guide EzView Network Communications Guide RevB July 2013 (V2.2) Supersedes: RevA (May 2011) Cincinnati Sub-Zero Products, LLC 513-772-8810 12011 Mosteller Road Cincinnati, Ohio 45241

More information

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A 6ES7314-6CG03-0AB0 Page 1 Product data sheet 6ES7314-6CG03-0AB0 SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED

More information

EXTERNAL DIMENSIONS AND PARTS

EXTERNAL DIMENSIONS AND PARTS FX2N-4DA SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4DA special

More information

ABB RTU560A Series CMU & Modules

ABB RTU560A Series CMU & Modules ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power

More information

Solid-State Timer H3G

Solid-State Timer H3G ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In

More information

1701/22 FieldMonitor Management Interface Module

1701/22 FieldMonitor Management Interface Module 1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides

More information

CPUs - CPU 315-2 PN/DP

CPUs - CPU 315-2 PN/DP Overview The CPU with a medium program memory and quantity framework High processing performance in binary and floating-point arithmetic Used as a central controller on production lines with central and

More information

In-Sight Hardware specifications

In-Sight Hardware specifications specifications In-Sight 5000, 5100, 5400, 5400S, 5400C, 5401, and 5403 4020 Linz/Austria Pummererstr. 36 Tel.: +43-(0)70-7646-0* www.schmachtl.at Memory Job/Program 16MB non-volatile flash memory; Unlimited

More information

DeviceNet Communications Unit for EJ1 Temperature Controllers OPERATION MANUAL

DeviceNet Communications Unit for EJ1 Temperature Controllers OPERATION MANUAL Cat. No. H155-E1-02 DeviceNet Communications Unit for EJ1 Temperature Controllers OPERATION MANUAL DeviceNet Communications Unit for EJ1 Temperature Controllers Operation Manual Revised July 2008 iv Preface:

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages

More information

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen Equipment, facilities, and service networks for data collection/logging, data transfer via e-mail/website, and system streamlining can be established without special knowledge. Energy saving system in

More information

L5354 ControlNet Communications Interface

L5354 ControlNet Communications Interface L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or

More information

MEMOBUS/Modbus Communications

MEMOBUS/Modbus Communications 2 2.1 MEMOBUS/MODBUS CONFIGURATION............260 2.2 COMMUNICATION SPECIFICATIONS..............261 2.3 COMMUNICATION TERMINAL RESISTANCE........262 2.4 CONNECTING A PLC...........................263 2.5

More information

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value. Vision OPLC V350-35-RA22/V350-J-RA22 Technical Specifications The Unitronics V350-35-RA22/V350-J-RA22 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog,

More information

CJ1W-SPU01-V2 CSM_CJ1W-SPU01-V2_DS_E_7_1

CJ1W-SPU01-V2 CSM_CJ1W-SPU01-V2_DS_E_7_1 CJ-series High-speed Data Storage Unit (SPU Unit) CSM DS_E_7_1 High-speed Collection of System Data The CPU Unit can collect large amounts of process data, operation data, inspection data, and other controlled

More information

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved. SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,

More information

SAFETY PRECAUTION. (Always read these instructions before using the products.)

SAFETY PRECAUTION. (Always read these instructions before using the products.) SAFETY PRECAUTION (Always read these instructions before using the products.) When designing the system, always read the relevant manuals and give sufficient consideration to safety. During the exercise,

More information

How to read this guide

How to read this guide How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information

More information

Flexible Counter Series in DIN size 24 x 48 mm

Flexible Counter Series in DIN size 24 x 48 mm Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display 2 different supply voltages available: independent of mains supply with lithium battery

More information

Cat. No. W02E-EN-01. SYSMAC CJ-series CJ1W-CTL41-E 4-Channel Counter Unit OPERATION MANUAL

Cat. No. W02E-EN-01. SYSMAC CJ-series CJ1W-CTL41-E 4-Channel Counter Unit OPERATION MANUAL Cat. No. W02E-EN-01 SYSMAC CJ-series CJ1W-CTL41-E 4-Channel Counter Unit OPERATION MANUAL SYSMAC CJ-series CJ1W-CTL41-E 4-Channel Counter Unit Operation Manual Produced September 2004 i ii Notice: OMRON

More information

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output NTA CPU board PROCESS INTERFACES NTA is a CPU board for STAR DualBus DCS systems. NTA provides the internal bus communication, managing all I/O boards of the STAR DualBus modular system. NTA also manages

More information

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode: COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Automation Unit TM 1703 ACP Flexible automation and telecontrol Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not

More information

ALARM SYSTEM PLC. MODICON 984 - A120 Description. 01 September 2000 ASI GmbH B. Dittmer LADESTRASSE 3-3A 28197 BREMEN

ALARM SYSTEM PLC. MODICON 984 - A120 Description. 01 September 2000 ASI GmbH B. Dittmer LADESTRASSE 3-3A 28197 BREMEN ALARM SYSTEM PLC MODICON 984 - A120 Description 01 September 2000 ASI GmbH B. Dittmer LADESTRASSE 3-3A 28197 BREMEN Alarm System PLC 984 - A120, Sheet 2 1. Compact Hardware The Alarm- and Monitoring System,

More information

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0 4 SIMATIC S7-300 Central processing units CPU 312C to CPU 317F-2 DP CPU 317F-2 DP The failsafe CPU with a large program memory and quantity framework for demanding applications For configuration of a failsaf

More information

PNSPO! Modbus Solution CP1H / CP1L / CJ1 / CJ2 / CS1. Version 2.05 6/18/2009

PNSPO! Modbus Solution CP1H / CP1L / CJ1 / CJ2 / CS1. Version 2.05 6/18/2009 PNSPO!! Modbus Solution CP1H / CP1L / CJ1 / CJ2 / CS1 Version 2.05 6/18/2009 Section 1. Overview The Omron CP1H and CP1L PLCs offer a built in function called Easy Modbus, that performs a Modbus RTU Master

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8. ZFX-C/25-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection via

More information

Multi-functionality Condensed into an All-in-one Package

Multi-functionality Condensed into an All-in-one Package Multi-functionality Condensed into an All-in-one Package Expanded Range of Applications with Built-in Pulse Outputs for 4 Axes, Analog I/O, and Serial Communications, and with a USB Port as a Standard

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053. PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8. ZFX-C10/15-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection

More information

Modular I/O system Rugged Modular I/O System Solutions EN-50155 certified for railway applications

Modular I/O system Rugged Modular I/O System Solutions EN-50155 certified for railway applications The systems and devices of the MODULAR I/O family are the Tecnint HTE solutions for industrial and technological application of automation, acquisition and management that require particularly robustness

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Introduction. - Please be sure to read and understand Precautions and Introductions in CX-Simulator Operation Manual and

Introduction. - Please be sure to read and understand Precautions and Introductions in CX-Simulator Operation Manual and Introduction - Please be sure to read and understand Precautions and Introductions in CX-Simulator Operation Manual and CX-Programmer Operation Manual before using the product. - This guide describes the

More information

Multifunction Digital Timer

Multifunction Digital Timer Multifunction Digital Timer 1/16 DIN Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.

More information

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm Slim Plug-In Safety Relay Slim Safety Relay for Machine Control H Slim body only 13 x 24 x 50 mm (six poles) H Four-pole and six-pole models are available H Terminal arrangement simplifies PCB pattern

More information

Remote Sources. Facility. Router

Remote Sources. Facility. Router A tally display system is an essential part of any broadcast or production environment. It must tell you where signals come from, where they go, and how they are being used. In a typical multi-production

More information

MBP_MSTR: Modbus Plus Master 12

MBP_MSTR: Modbus Plus Master 12 Unity Pro MBP_MSTR 33002527 07/2011 MBP_MSTR: Modbus Plus Master 12 Introduction This chapter describes the MBP_MSTR block. What s in this Chapter? This chapter contains the following topics: Topic Page

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

http://support.automation.siemens.com/ww/view/en/4067870&td=1

http://support.automation.siemens.com/ww/view/en/4067870&td=1 6ES7316-2AG00-0AB0 SIMATIC S7-300, CPU 316 Technical / CAx data nmlkji Technical Data nmlkj CAx data As of 2010-01-24 Power supply Input voltage Rated value (DC) permissible range, lower limit (DC) permissible

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

Disturbance Recoder SPCR 8C27. Product Guide

Disturbance Recoder SPCR 8C27. Product Guide Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power

More information

Optimize your simple machines... Modicon M218 Selection Guide

Optimize your simple machines... Modicon M218 Selection Guide Optimize your simple machines... Modicon M218 Selection Guide Compact Solution for Simple Machines Optimized Logic Controller Modicon M218 With intelligent software platform, specialized functional s,

More information

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK Field busses are industrial control systems using Programmable Logic lers (PLC) to control and manage field devices found in industrial environments. The communication

More information

CPM1A. Basic Configuration. Micro Programmable Controller

CPM1A. Basic Configuration. Micro Programmable Controller Micro Programmable Controller CPM1A The CPM1A series micro controllers solve both basic and semi-complex applications. The brick style models include DC inputs/transistor or relay outputs to meet your

More information

O C M III. Open Channel Flow Monitor

O C M III. Open Channel Flow Monitor O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this

More information

UniPi technical documentation REV 1.1

UniPi technical documentation REV 1.1 technical documentation REV 1.1 Contents Overview... 2 Description... 3 GPIO port map... 4 Power Requirements... 5 Connecting Raspberry Pi to UniPi... 5 Building blocks... 5 Relays... 5 Digital Inputs...

More information

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &

More information

CC-Link Ver.1.10 Compatible

CC-Link Ver.1.10 Compatible Model Title CC-Link Ver.1.10 Compatible CC-Link Flexible Cable Conformance Test Specifications Management number : BAP-C0401-009 CC-Link Partner Association (1/12) Revisions Revision item Revision Description

More information

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5 - TFT - 96 MB Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis

More information

OPTICAL FIBER repeaters/ isolators

OPTICAL FIBER repeaters/ isolators OPTICAL FIBER repeaters/ isolators FUNCTINALITY AND RELIABILITY' Optical Fiber converters give the possibilità to extend on Optical Fiber (also at the same time) every type of network/bus (LAN/Ethernet,

More information