1 6ES7316-2AG00-0AB0 SIMATIC S7-300, CPU 316 Technical / CAx data nmlkji Technical Data nmlkj CAx data As of Power supply Input voltage Rated value (DC) permissible range, lower limit (DC) permissible range, upper limit (DC) Input current Rated value at DC 24 V Inrush current, max. Current consumption Power loss, max. Memory Type of storage RAM integrated Load memory expandable FEPROM expandable FEPROM, max. integrated RAM, max. Backup present with battery without battery 24 V 20.4 V 28.8 V 1000 ma 8 A 8 W 128 KByte; 128 KByte / 42 K instructions RAM (integrated) ; Flash-EPROM 4 MByte 192 KByte CPU/blocks DB Number, max. 511 FB Number, max. 256 FC Number, max. 256 OB Number of free cycle OBs 1; OB 1 Number of time alarm OBs 1; OB 10 Number of watchdog interrupts 1; OB 35 Number of process alarm OBs 1; OB 40 Number of startup OBs 1; OB 100 ; all blocks ; 4 KB: bit memory, counter, times and data Page 1 of 5

2 Nesting depth per priority class 8 CPU/processing times for bit operations, min. 0.3 µs for bit operations, max. 0.6 µs for word operations, min. 1 µs for fixed point arithmetic, min. 2 µs for floating point arithmetic, min. 50 µs for time/counter operations, min. 12 µs Times/counters and their remanence S7 counter Number 64 upper limit 63 upper limit 63 Counting range lower limit 1 upper limit 999 S7 times Number 128 upper limit 127 upper limit 127 Time range lower limit 10 ms upper limit 9990 s Data areas and their remanence Flag Number, max. 256 Byte Remanence available ; MB 0 to MB to 2047 (M 0.0 to M 255.7, ) 0 to 2047 (M 0.0 to M 255.7, ) Address area I/O address area Inputs 2 KByte Outputs 2 KByte Process image Inputs 128 Byte Outputs 128 Byte Digital channels Inputs Outputs Inputs, of which central 1024 Page 2 of 5

3 Outputs, of which central 1024 Analog channels Inputs 1024 Outputs 1024 Inputs, of which central 256 Outputs, of which central 128 Hardware config. Connectable programming devices/pcs PGs/PCs with STEP 7 connectable via interface Modules per rack, max. 32 Number of modules per DP slave interface, max. 64 Number of DP masters integrated 1 via CP 1; CP Number of operable FMs and CPs (recommended) FM 8 CP, point-to-point 4 CP, LAN 2 Time Clock Hardware clock (real-time clock) Communication functions PG/OP communication Global data communication S7 basic communication S7 communication as server S5-compatible communication ; via loadable blocks Standard communication (FMS) ; via loadable blocks Number of connections of which, dynamic 8 of which static 4 Cable length, max m; without repeaters: 50 m; with 2 repeaters: 1100 m; with 10 repeaters in series: 9100 m; via fiber optic cable: 23.8 km (with 16 star hubs or OLMs) 1st interface Functionality Services PG/OP communication Global data communication S7 basic communication S7 communication Number of nodes, max. 32 Transmission speeds, max kbit/s Page 3 of 5

4 Transmission speeds, min kbit/s 2nd interface Functionality DP master DP slave DP master Services equidistance support Activation/deactivation of DP slaves direct data exchange (cross traffic) ; Transmitter and receiver Number of DP slaves, max. 124 Useful data per DP slave Useful data per DP slave, max. 244 Byte CPU/programming Programming language STEP 7 ; V5.0 LAD FUP AWL SCL CFC GRAPH HiGraph Software libraries Process diagnostics Software controller ; depending on the required memory space and the resulting execution time Operational stocks Binary logic operations, bracketed operations, result allocation, saving, counting, loading, transferring, comparing, shifting, rotating, complementation, calling blocks, fixed point arithmetic, floating point arithmetic, jump functions Nesting levels 8 User program protection/password protection Program organization linear, structured System functions (SFC) Interrupt and error processing, copy data, clock functions, diagnostic functions, module parameterization, operating mode transitions Cycle time monitoring lower limit 1 ms upper limit 6000 ms preset 150 ms Dimensions Width 80 mm Height 125 mm Depth 130 mm Weights Weight, approx. 530 g; Memory card 16 g Page 4 of 5

5 Siemens AG Corporate Information - Privacy Policy - Terms of Use Page 5 of 5

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2 6ES7315-2AG10-0AB0 Page 1 Product data sheet 6ES7315-2AG10-0AB0 SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2. INTERFACE DP-MASTER/SLAVE

More information

CPUs - CPU 315-2 PN/DP

CPUs - CPU 315-2 PN/DP Overview The CPU with a medium program memory and quantity framework High processing performance in binary and floating-point arithmetic Used as a central controller on production lines with central and

More information

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0 4 SIMATIC S7-300 Central processing units CPU 312C to CPU 317F-2 DP CPU 317F-2 DP The failsafe CPU with a large program memory and quantity framework for demanding applications For configuration of a failsaf

More information

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A 6ES7313-5BF03-0AB0 Page 1 Product data sheet 6ES7313-5BF03-0AB0 SIMATIC S7-300, CPU 313C, COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO 1 PT100, 3 FAST COUNTERS (30 KHZ), INTEGRATED 24V DC POWER SUPPLY,

More information

CPU 319-3 PN/DP. Function

CPU 319-3 PN/DP. Function CPU 319-3 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in the

More information

SIMATIC S Central processing units CPU /30 Siemens ST

SIMATIC S Central processing units CPU /30 Siemens ST Overview The most powerful CPU Can be used in the most sophisticated installations in the upper performance range With two slots for IF modules Technical specifications Product status Firmware version

More information

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A 6ES7314-6CG03-0AB0 Page 1 Product data sheet 6ES7314-6CG03-0AB0 SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED

More information

Data sheet SLIO CPU 015 (015-CEFPR00)

Data sheet SLIO CPU 015 (015-CEFPR00) Data sheet SLIO CPU 015 (015-CEFPR00) Technical data Order no. 015-CEFPR00 SLIO CPU 015 Module ID - General information Note - Features SPEED7 technology 256 kb work memory Memory extension (max. 512 kb)

More information

SIMATIC S7-300. 4/2 Introduction. 4/4 Central processing units. 4/34 Digital modules. 4/44 Analog modules. 4/55 F digital /analog modules

SIMATIC S7-300. 4/2 Introduction. 4/4 Central processing units. 4/34 Digital modules. 4/44 Analog modules. 4/55 F digital /analog modules /2 Introduction / Central processing units /3 Digital modules / Analog modules /55 F digital /analog modules /61 Ex input/output modules /65 Function modules /65 FM 350-1 counter module /67 FM 350-2 counter

More information

The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system:

The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system: CP 342-5 FO Function The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61 158/61784, master or slave) PG/OP communication S7

More information

CP 342-5. Page 1342 Mar 2008 Siemens ITS

CP 342-5. Page 1342 Mar 2008 Siemens ITS CP 342-5 Function The CP 342-5 provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61158/61784, master or slave) PG/OP communication S7 communication

More information

The CP 342-5 provides access to different communication services of the PROFIBUS bus system:

The CP 342-5 provides access to different communication services of the PROFIBUS bus system: SIPLUS CP 342-5 Function The CP 342-5 provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61158/61784, master or slave) PG/OP communication S7

More information

SIMATIC S7-300. 5/30 SIPLUS digital modules 5/30 SIPLUS SM 322 digital output module. 5/31 Analog modules 5/31 SM 331 analog input module

SIMATIC S7-300. 5/30 SIPLUS digital modules 5/30 SIPLUS SM 322 digital output module. 5/31 Analog modules 5/31 SM 331 analog input module /2 Central processing units /2 Standard CPUs /2 CPU 312 /2 CPU 314 /2 CPU 31-2 DP /2 CPU 31-2 PN/DP /3 CPU 317-2 PN/DP /17 Fail-safe CPUs /17 CPU 31F-2 DP /17 CPU 31F-2 PN/DP /18 CPU 317F-2 PN/DP /30 SIPLUS

More information

SIMATIC S7-300 4/2 Introduction Function modules (continued) 4/4 Central processing units 4/38 SIPLUS central processing units 4/40 Digital modules

SIMATIC S7-300 4/2 Introduction Function modules (continued) 4/4 Central processing units 4/38 SIPLUS central processing units 4/40 Digital modules /2 Introduction /2 S7-300/S7-300F / Central processing units / CPU 312C to CPU 317F-2 DP /38 SIPLUS central processing units /38 SIPLUS CPU 312C, CPU 313C, CPU 31, CPU 315-2 DP /0 Digital modules /0 SM

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE T I A Training Document Page 1 of 25 Module This document has been written by Siemens AG for training

More information

SIMATIC. C7-621, C7-621 AS-i Control Systems. Volume 2 Working with C7 A B C D E. Contents. User Information. Introduction. Startup.

SIMATIC. C7-621, C7-621 AS-i Control Systems. Volume 2 Working with C7 A B C D E. Contents. User Information. Introduction. Startup. Contents User Information Introduction 1 Startup 2 SIMATIC C7-621, C7-621 AS-i Control Systems Volume 2 Working with C7 Manual Controlling Controlling with the C7 CPU 3 Addessing, Parameter Assignment,

More information

S7-1500/S7-1500F Technical Data

S7-1500/S7-1500F Technical Data Standard CPUs CPU 1511-1 PN CPU 1513-1 PN CPU 1515-2 PN Type Standard CPU Standard CPU Standard CPU Dimensions 35 x 147 x 129 mm 35 x 147 x 129 mm 70 x 147 x 129 mm Spare part availability after 10 years

More information

SOFTLINK 300. CPU Specifications. Reference Manual

SOFTLINK 300. CPU Specifications. Reference Manual SOFTLINK 300 Reference Manual This manual is part of the documentation Package with the order number 300 314-1SL01 300 314-2DP01 300 315-2DP01 Edition 04/2011 i Preface Purpose of the manual This manual

More information

S7-1200 and STEP 7 Basic V10.5

S7-1200 and STEP 7 Basic V10.5 S7-1200 and STEP 7 Basic V10.5 S7-200 vs. S7-1200 Expandability S7-200 S7-1200 max. 7 Modules max. 3 Modules (CM) max. 8 Modules (SM) Page 2 Advantages of S7-1200, compared to S7-200 I/O Internal periphery

More information

Siemens AG 2011. 3/42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module

Siemens AG 2011. 3/42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module Siemens AG 2011 /2 Introduction /4 Central processing units /4 CPU 221 /4 CPU 222 /4 CPU 224 /4 CPU 224 XP, CPU 224 XPsi /4 CPU 226 /24 SIPLUS central processing units /24 SIPLUS CPU 221 /25 SIPLUS CPU

More information

Main Catalog 2012/2013 for specialists in automation and control technology

Main Catalog 2012/2013 for specialists in automation and control technology Main Catalog 2012/2013 for specialists in automation and control technology www.vipa.com Welcome to VIPA This is VIPA Specialists in automation and control systems. Developer in some to the most advanced

More information

Automating with STEP7 in LAD and FBD

Automating with STEP7 in LAD and FBD bisk Automating with STEP7 in LAD and FBD Programmable Controllers SIMATIC S7-300/400 by Hans Berger Publicis MCD Verlag Contents Indroduction 19 1 SIMATIC S7-300/400 Programmable Controller... 20 1.1

More information

Fieldbus slave modules with I/Os, DIO

Fieldbus slave modules with I/Os, DIO 140 Fieldbus slave modules with I/Os, DIO 1534CF00 1534CH00 1534PF00 1534PH00 1536CH00 1536CL10 1536PH00 1536PL00 Order number 1534CF00 1534CH00 1534PF00 1534PH00 Figure Type SM 153, CANopen slave, DIO

More information

PROFINET the Industrial Ethernet standard. Siemens AG 2013. Alle Rechte vorbehalten.

PROFINET the Industrial Ethernet standard. Siemens AG 2013. Alle Rechte vorbehalten. the Industrial Ethernet standard is 100% Ethernet is Ethernet Ethernet is the established standard in the IT world for fast exchange of data (IEEE 802.3) is always full duplex simultaneous communication

More information

Automating witfi STEP7 in LAD and FBD

Automating witfi STEP7 in LAD and FBD Automating witfi STEP7 in LAD and FBD Programmable Controllers SIMATIC S7-300/400 by Hans Berger 2nd revised edition, 2001 Publicis MCD Corporate Publishing Contents Contents Indroduction 19 1 SIMATIC

More information

Data Sheet SIMATIC S7-200 CPU 226 DC/DC/DC and CPU 226 AC/DC/Relay

Data Sheet SIMATIC S7-200 CPU 226 DC/DC/DC and CPU 226 AC/DC/Relay SIMATIC S7-200 and Table 1 Specifications for and Physical Size Dimensions (W x H x D) Weight Power loss (dissipation) CPU Features On-board digital inputs On-board digital outputs High speed counters

More information

SIMATIC NET. S7-CPs for PROFIBUS. CP 443-5 Basic. Manual Part B3

SIMATIC NET. S7-CPs for PROFIBUS. CP 443-5 Basic. Manual Part B3 SIMATIC NET S7-CPs for PROFIBUS Manual Part B3 CP 443-5 Basic 6GK7 443-5FX02-0XE0 Version 1 and higher (firmware version V4.0 and higher) for SIMATIC S7-400 / S7-400H Status and fault LEDs Mode selector

More information

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves

More information

PROFINET IO Diagnostics 1

PROFINET IO Diagnostics 1 PROFINET IO is a very cost effective and reliable technology. However, extensive installations can have thousands of PROFINET IO devices operating on many networks. The reliable operation of these networks

More information

SIMATIC S7-300C. The compact controllers for factory automation offer numerous innovations and new features. SIMATIC Controllers. siemens.

SIMATIC S7-300C. The compact controllers for factory automation offer numerous innovations and new features. SIMATIC Controllers. siemens. SIMATIC S7-300C The compact controllers for factory automation offer numerous innovations and new features. SIMATIC Controllers siemens.com/s7-300 SIMATIC the core component of Totally Integrated Automation

More information

S7-1500/S7-1500F Technical Data

S7-1500/S7-1500F Technical Data CPU 1511-1 PN CPU 1513-1 PN CPU 1515-2 PN Type Standard CPU Standard CPU Standard CPU Dimensions 35 x 125 x 130 mm 35 x 125 x 130 mm 70 x 147 x 129 mm Spare part availability after 10 years 10 years 10

More information

VIPA System 500S. SPEED7 - CPU 515-2AJ02 Manual

VIPA System 500S. SPEED7 - CPU 515-2AJ02 Manual VIPA System 500S SPEED7 - CPU 515-2AJ02 Manual HB145E_CPU RE_515-2AJ02 Rev. 10/23 June 2010 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to

More information

Compact Telecontrol System TM 1703 mic Simple, clever automation

Compact Telecontrol System TM 1703 mic Simple, clever automation Compact Telecontrol System Simple, clever automation Power Transmission and Distribution With the growing pressure on costs in virtually all processes, there is increasing need to also automate smaller

More information

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output NTA CPU board PROCESS INTERFACES NTA is a CPU board for STAR DualBus DCS systems. NTA provides the internal bus communication, managing all I/O boards of the STAR DualBus modular system. NTA also manages

More information

Analog modules - Analog input SM 331

Analog modules - Analog input SM 331 Overview Analog inputs For connection of voltage and current sensors, thermocouples, resistors and resistance s Application Analog input modules can be used to connect the PLC to analog process signals.

More information

Block Architecture and the LAD / STL / FBD Editor

Block Architecture and the LAD / STL / FBD Editor Block Architecture and the LAD / STL / FBD Editor OB 1 FB FB FC FB FB FB FB FC FC File: PRO1_06E.1 Objectives Upon completion of this chapter the participant will...... know the different types of S7 blocks...

More information

Service & Support. Configuration of an S7-300 as DP Slave on an S7-400H as DP Master Using the Y-link PROFIBUS DP. FAQ August 2011

Service & Support. Configuration of an S7-300 as DP Slave on an S7-400H as DP Master Using the Y-link PROFIBUS DP. FAQ August 2011 Cover Configuration of an S7-300 as DP Slave on an S7-400H as DP Master Using the Y-link PROFIBUS DP FAQ August 2011 Service & Support Answers for industry. Question This entry is from the Service&Support

More information

SIMATIC. System Software for S7-300 and S7-400 Program Design A B C D. Programming Manual C79000-G7076-C506-01. Preface, Contents

SIMATIC. System Software for S7-300 and S7-400 Program Design A B C D. Programming Manual C79000-G7076-C506-01. Preface, Contents SIMATIC System Software for S7-300 and S7-400 Program Design Programming Manual Preface, Contents How to Design Control Programs 1 Structuring the User Program 2 Organization Blocks and Executing the 3

More information

Help File PROFIBUS DP communication between Freelance Control System and Siemens S7-300 PLC

Help File PROFIBUS DP communication between Freelance Control System and Siemens S7-300 PLC Freelance Distributed Control System Help File PROFIBUS DP communication between Freelance Control System and Siemens S7-300 PLC Summary The purpose of this document is to provide a viable solution for

More information

Ponto Series. A new concept for automation

Ponto Series. A new concept for automation Ponto Series A new concept for automation Programmable Controller Remote I/O for Field Buses Special models of I/O modules Web connection Ponto Series Programmable Controller High connectivity CPUs Direct

More information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute

More information

Redundant PROFIBUS DP network with S7-400H System and Ponto PO5063V5 Remote

Redundant PROFIBUS DP network with S7-400H System and Ponto PO5063V5 Remote Application Note NAP102 Redundant PROFIBUS DP network with Altus Sistemas de Informática S.A. Página: 1 Contents 1 Description... 3 2 Introduction... 3 3 Reference Architecture... 4 4 PROFIBUS Project...

More information

For System Solutions with Emphasis on Production Engineering. Product Brief June 2002

For System Solutions with Emphasis on Production Engineering. Product Brief June 2002 For System Solutions with Emphasis on Production Engineering Product Brief June 00 Introduction The S7-300 is the most often sold SIMAT- IC controller which makes successful automation solutions possible.

More information

Start-up of IVI-KHD2-4HRX, IVI-KHA6-4HRX at S7-300 V1.1. Table of Contents TABLE OF CONTENTS... 1

Start-up of IVI-KHD2-4HRX, IVI-KHA6-4HRX at S7-300 V1.1. Table of Contents TABLE OF CONTENTS... 1 Table of Contents TABLE OF CONTENTS... 1 1. DESCRIPTION OF HARDWARE... 2 1.1 Modules and devices... 2 1.2 Set-up and installation... 2 2. SETTING UP PARAMETERS... 2 2.1 Setting up parameters in accordance

More information

SIMATIC. Testing Your S7 Programs with S7-PLCSIM. Preface, Contents. Product Overview. Installing the S7-PLCSIM Software. Getting Started with

SIMATIC. Testing Your S7 Programs with S7-PLCSIM. Preface, Contents. Product Overview. Installing the S7-PLCSIM Software. Getting Started with Preface, Contents SIMATIC Testing Your S7 Programs with S7-PLCSIM User Manual Product Overview 1 Installing the S7-PLCSIM Software 2 Getting Started with S7-PLCSIM 3 Running a Program on the Simulated

More information

Light scene push button 8gang comfort flush-mounted 751688xx

Light scene push button 8gang comfort flush-mounted 751688xx 751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional

More information

DATA COMMUNICATION BETWEEN PROGRAMMABLE LOGIC CONTROLLERS IN THE INDUSTRIAL DISTRIBUTION APPLICATIONS

DATA COMMUNICATION BETWEEN PROGRAMMABLE LOGIC CONTROLLERS IN THE INDUSTRIAL DISTRIBUTION APPLICATIONS DATA COMMUNICATION BETWEEN PROGRAMMABLE LOGIC CONTROLLERS IN THE INDUSTRIAL DISTRIBUTION APPLICATIONS Anna BYSTRICANOVA 1, Andrej RYBOVIC 1 1 Department of Mechatronics and Electronics, Faculty of Electrical

More information

Organization Blocks (1)

Organization Blocks (1) Organization Blocks (1) Operating system OB1 FC FB FB FC SFC System Functions SFB System Function Blocks Other OBs File: PRO1_12E.1 Objectives Upon completion of the chapter the participant will......

More information

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE A5. PLC-Simulation with S7-PLCSIM

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE A5. PLC-Simulation with S7-PLCSIM Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE A5 PLC- Simulation with S7-PLCSIM T I A Training document Page 1 of 14 Module A5 This document was

More information

SIMATIC S The modular controller for factory automation sets standards in performance and new features. SIMATIC Controllers. siemens.

SIMATIC S The modular controller for factory automation sets standards in performance and new features. SIMATIC Controllers. siemens. SIMATIC S7-300 The modular controller for factory automation sets standards in performance and new features. SIMATIC Controllers siemens.com/s7-300 SIMATIC the core component of Totally Integrated Automation

More information

Bellplast S.R.L. www.caipe.com Informe del Dpto. Técnico

Bellplast S.R.L. www.caipe.com Informe del Dpto. Técnico - CPU 306 EX - CPU306EX Performance Indexes K306EX-14AT K306EX-24AR CPU Program Execution DI Points DO Points Application Memory Program Backup Memory Area 16-bit industrial Typical Bool instruction time:

More information

Siemens AG 2013. 6/56 Digital modules 6/56 SM 421 digital input module 6/59 SM 422 digital output module

Siemens AG 2013. 6/56 Digital modules 6/56 SM 421 digital input module 6/59 SM 422 digital output module Siemens AG 2013 SIMATIC S7-400 /2 Introduction /4 Central processing units /4 Standard CPUs /4 CPU 412 /8 CPU 414 /13 CPU 41 /18 CPU 417 /21 SIPLUS Standard CPUs /21 SIPLUS CPU 412 /22 SIPLUS CPU 414 /23

More information

DS1621 Digital Thermometer and Thermostat

DS1621 Digital Thermometer and Thermostat Digital Thermometer and Thermostat www.dalsemi.com FEATURES Temperature measurements require no external components Measures temperatures from 55 C to +125 C in 0.5 C increments. Fahrenheit equivalent

More information

SIMATIC NET. S7-CPs for PROFIBUS Configuring and Commissioning

SIMATIC NET. S7-CPs for PROFIBUS Configuring and Commissioning SIMATIC NET S7-CPs for PROFIBUS Configuring and Commissioning Manual Part A General Application Preface, Contents Communication over S7-CPs 1 Characteristics of the PROFIBUS CPs 2 NCM S7 for PROFIBUS CPs

More information

SIMATIC NET. Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs. Preface. Overview and general information on working with FCs and FBs

SIMATIC NET. Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs. Preface. Overview and general information on working with FCs and FBs Preface Overview and general information on working with FCs and FBs 1 SIMATIC NET Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs Programming Manual FCs / FBs for Industrial Ethernet 2

More information

Technical Training Module ( 30 Days)

Technical Training Module ( 30 Days) Annexure - I Technical Training Module ( 30 Days) Section 1 : Programmable Logic Controller (PLC) 1. Introduction to Programmable Logic Controller - A Brief History, Need and advantages of PLC, PLC configuration,

More information

Flexible Counter Series in DIN size 24 x 48 mm

Flexible Counter Series in DIN size 24 x 48 mm Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display 2 different supply voltages available: independent of mains supply with lithium battery

More information

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules

More information

A.4 Specifications for the CPU 224

A.4 Specifications for the CPU 224 A.4 Specifications for the CPU 224 Specifications for and Physical Size Dimensions (W x H x D) Weight Power loss (dissipation) CPU Features On-Board digital inputs On-Board digital outputs High speed counters

More information

Cover sheet. Reading out the topology data of a PROFINET IO system SFB52 "RDREC" FAQ September 2009. Service & Support. Answers for industry.

Cover sheet. Reading out the topology data of a PROFINET IO system SFB52 RDREC FAQ September 2009. Service & Support. Answers for industry. Cover sheet Reading out the topology data of a PROFINET IO system FAQ September 2009 Service & Support Answers for industry. Question This entry originates from the Service&Support Portal of Siemens AG,

More information

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved. SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,

More information

Siemens AG V5.5 SP2 or higher with a GSD file. V5.5 SP2 or higher with a GSD file PROFINET as of GSD version/ V2.3 v2.3 / - V2.3 v2.

Siemens AG V5.5 SP2 or higher with a GSD file. V5.5 SP2 or higher with a GSD file PROFINET as of GSD version/ V2.3 v2.3 / - V2.3 v2. Siemens AG 2013 SIMATIC S7-1500 Overview CM PtP Modules for serial communication connections, scaled according to interface types, protocols, and performance versions with different physical transmission

More information

General information. Display. Control elements

General information. Display. Control elements Data sheet SIMATIC MP 377 PRO 15" TOUCH MULTIPANEL, WINDOWS CE 5.0 15" COLOR-TFT-DISPLAY 12 MB USER MEMORY CONFIGURABLE FROM WINCC FLEXIBLE 2007 General information Customer-specific configuration Display

More information

applicomio Profibus-DP

applicomio Profibus-DP BradCommunications Profibus-DP network interface cards allow deterministic I/O data acquisition for PC-based control applications. Features New! Support of Windows 32-bit and 64-bit (WoW64) Support of

More information

I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP

I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP 1. Functions An I. S. 1 fieldstation can be equipped with a primary and a redundant central unit (), whereby each has its own independent PROFIBUS

More information

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300 SIMATIC SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300 Manual Preface, Contents Characteristics and Technical Specifications of the SM 335 Connecting the Inputs and Outputs of the

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05 Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE PROFINET with IO-Controller CP343-1 Advanced and IO-Device ET 200S T I A Training Document Page 1 of

More information

UniPi technical documentation REV 1.1

UniPi technical documentation REV 1.1 technical documentation REV 1.1 Contents Overview... 2 Description... 3 GPIO port map... 4 Power Requirements... 5 Connecting Raspberry Pi to UniPi... 5 Building blocks... 5 Relays... 5 Digital Inputs...

More information

DS1621 Digital Thermometer and Thermostat

DS1621 Digital Thermometer and Thermostat www.maxim-ic.com FEATURES Temperature measurements require no external components Measures temperatures from -55 C to +125 C in 0.5 C increments. Fahrenheit equivalent is -67 F to 257 F in 0.9 F increments

More information

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012 Cover Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012 Applications & Tools Answers for industry. Siemens Industry Online Support This

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04 Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL PROFINET with IO Controller CPU 315F-2 PN/DP and IO Device ET 200S T I A Training Document Page 1 of

More information

Timing relay module DC 24 110 V, programmable

Timing relay module DC 24 110 V, programmable Subject to technical modification 815000.00 Identification Type ZR6-5000.00 Product version Datasheet version 00 Use/Area of application Description The programmable timing relay consists of 2 changeover

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

TDC 2000 TDC Universal Control Network UCN. Distributed Control Systems for Industrial Automation. Honeywell

TDC 2000 TDC Universal Control Network UCN. Distributed Control Systems for Industrial Automation. Honeywell TDC 2000 TDC 3000 Universal Control Network UCN Distributed Control Systems for Industrial Automation Honeywell Product PDF Presented by DCScenter.com For Product Needs: Email: sales@dcscenter.com Call:

More information

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01 WinCC Communication Manual Manual 2 This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 Release: September 1999 WinCC, SIMATIC, SINEC, STEP are trademarks of Siemens.

More information

C7 Control Systems PLC and Operator Panel in one device. Product Brief November 2003

C7 Control Systems PLC and Operator Panel in one device. Product Brief November 2003 C7 Control Systems PLC and Operator Panel in one device Product Brief November 2003 Overview, advantages, innovation SIMATIC C7 control systems comprising SIMATIC OP & S7-300 SIMATIC OP SIMATIC S7-300

More information

Identification System. FC 44 Function for ASM 450 With Supplements for FB 240. Contents. General Features Hardware Description of ASM 450

Identification System. FC 44 Function for ASM 450 With Supplements for FB 240. Contents. General Features Hardware Description of ASM 450 MOBY FC 44 Function for ASM 450 With Supplements for FB 240 Technical Description Identification System Contents General Features Hardware Description of ASM 450 Specifications of the FC 44 BEDB Command

More information

Programmable Controller G Series. New. Models

Programmable Controller G Series. New. Models Programmable Controller G Series The IMO G6 is a very compact modular programmable controller offering extremely high performance. It is ideal for all applications from process control to machine control

More information

Push button 3gang standard flush-mounted 751633xx

Push button 3gang standard flush-mounted 751633xx Documentation Product name: Push button 3gang standard Design: device (up) ETS search path: Push button / Push button 3gang / Push button 3gang standard Functional description: The push button 3gang standard

More information

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3 Contents Moxa Technical Support Team support@moxa.com 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...

More information

How to configure an Anybus PROFINET IO Slave module with a Siemens Step7 PLC

How to configure an Anybus PROFINET IO Slave module with a Siemens Step7 PLC How to configure an Anybus PROFINET IO Slave module with a Siemens Step7 PLC www.anybus.com HMS Industrial Networks AB Page 1 (25) More information about the network and products The most recent manuals

More information

Automating with STEP7 in STL and SCL

Automating with STEP7 in STL and SCL Automating with STEP7 in STL and SCL Programmable Controllers SIMATIC S7-300/400 by Hans Berger 3rd revised edition, 2005 Publicis Corporate Publishing Table ofcontents Table of Contents Introduction................

More information

MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B0875-2.1 en

MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B0875-2.1 en MP85 / MP85DP Data sheet MP85 MP85DP Special features - 100% quality control of the production process - Universal twin-channel amplifier for many of the usual market sensors - Powerful algorithms for

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A3 'Startup' PLC Programming with STEP 7

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A3 'Startup' PLC Programming with STEP 7 Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE 'Startup' PLC Programming with STEP 7 T I A Training Document Page 1 of 48 Module This document has

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12

TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12 6AV3017-1NE30-0AX0 Page 1 Product data sheet 6AV3017-1NE30-0AX0 TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12 Supply voltage

More information

STM32 F-2 series High-performance Cortex-M3 MCUs

STM32 F-2 series High-performance Cortex-M3 MCUs STM32 F-2 series High-performance Cortex-M3 MCUs STMicroelectronics 32-bit microcontrollers, 120 MHz/150 DMIPS with ART Accelerator TM and advanced peripherals www.st.com/mcu STM32 F-2 series The STM32

More information

Connection between two SIMATIC S7-300 in Profibus DP network

Connection between two SIMATIC S7-300 in Profibus DP network Connection between two SIMATIC S7-300 in Profibus DP network Hardware that is needed to complete this project: Two Siemens Simatic S7-300 with Profibus DP interface and Ethernet module. A cable of RS 485

More information

SIMATIC. STEP 7 From S5 to S7. Preface, Contents Part 1: Planning Your Conversion. Introduction. Hardware. Converter Manual.

SIMATIC. STEP 7 From S5 to S7. Preface, Contents Part 1: Planning Your Conversion. Introduction. Hardware. Converter Manual. SIMATIC STEP 7 Converter Manual Preface, Contents Part 1: Planning Your Conversion Introduction 1 Hardware 2 Software 3 Part 2: Converting Programs Procedure 4 Preparing for Conversion 5 Conversion 6 Editing

More information

Time relay module DC 24 110 V, programmable with positive action contacts

Time relay module DC 24 110 V, programmable with positive action contacts Subject to technical modification 815008.00 Identification Type ZR6-5008.00 Product version Datasheet version 00 Use/Application/Properties Description The programmable time relay consists of 1 relay with

More information

Software redundancy for SIMATIC S7 SIMATIC. S7-300/S7-400 Software redundancy for SIMATIC S7. Contents 1

Software redundancy for SIMATIC S7 SIMATIC. S7-300/S7-400 Software redundancy for SIMATIC S7. Contents 1 Contents 1 How should I use this description? - A tip for 2 readers SIMATIC S7-300/S7-400 Software redundancy for SIMATIC S7 Function Manual Introduction 3 How software redundancy works 4 Blocks for software

More information

Bidirectional wireless communication using EmbedRF

Bidirectional wireless communication using EmbedRF Bidirectional wireless communication using EmbedRF 1. Tools you will need for this application note... 2 2. Introduction... 3 3. Connect EmbedRF Board to USB Interface Board... 3 4. Install and Run EmbedRF

More information

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

Technical Description

Technical Description abcxyz Contents 1. General...1 2. Block Diagram...2 3. First Steps...2 4. Technical Data...3 4.1 AS-Interface...3 4.2 Pin Out...4 4.3 Supply of Periphery...4 4.4 Inputs...5 4.5 Outputs...5 4.6 Mechanical

More information

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA) SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA) Siemens Automation Cooperates with Education TIA Portal Module 010-030 IEC Timers and IEC Counters at the

More information

Siemens AG 2014. Inputs 8 8 8 8 of which can be used 4 (0 to 10 V) 4 (0 to 10 V)

Siemens AG 2014. Inputs 8 8 8 8 of which can be used 4 (0 to 10 V) 4 (0 to 10 V) 8 Basic 24CE 12/24RCE 24RCE 230RCE Inputs 8 8 8 8 of which can be used 4 (0 to 10 V) 4 (0 to 10 V) in analog mode Input/supply voltage 24 V DC 12...24 V DC 24 V AC/DC 115...230 V AC/DC Permissible range

More information

ABB RTU560A Series CMU & Modules

ABB RTU560A Series CMU & Modules ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power

More information

SIMOTION. Supplement to the FM 350-1, FM 350-2 and FM 352 Modules. Preface. Description 1. Function blocks of the FM 350-1

SIMOTION. Supplement to the FM 350-1, FM 350-2 and FM 352 Modules. Preface. Description 1. Function blocks of the FM 350-1 Preface SIMOTION Supplement to the FM50-1, FM50-2 and FM 352 Modules SIMOTION Supplement to the FM 350-1, FM 350-2 and FM 352 Modules Function Manual Description 1 Function blocks of the FM 350-1 2 Function

More information