CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output
|
|
- Lizbeth Powell
- 8 years ago
- Views:
Transcription
1 NTA CPU board PROCESS INTERFACES NTA is a CPU board for STAR DualBus DCS systems. NTA provides the internal bus communication, managing all I/O boards of the STAR DualBus modular system. NTA also manages the LAN tcp/ip communication between nodes of the DCS system and to operator and engineering stations. CPU ARM926EJ-S DualBus control and redundant systems management.funzione watch-dog 1 Fast Ethernet 10/100Mbps port 4 insulated serial ports used for communication purposes 1 high speed serial line used in redundant configurations of NTA board for master/slave communication 1 USB 2.0 port 1 MMC/SD card slot Processor Memory FLASH Dinamic RAM Static RAM Extension Networking Serial Communication Input/Output CPU ARM926EJ-S, 200MHz 256MB 64MB 512KByte with battery back-up MMC/SD card interface Fast Ethernet 10/100 Mbps port Fast communication channel for redundant NTA configuration Two asynchronous RS232 interfaces (UART 16C654 standard) Two asynchronous RS232/RS485 (UART 16C654 standard) StreamBus link management toward the communication controllers USB 2.0 port One serial line for local monitoring purposes 6 digital input 2 digital open-drain alarm output
2 IPRO Other Features Diagnostics Display Power Supply Voltage 5V (±5%) Consumption Less than 600mA 3 programmable interval timer (standard 82C54) Operating mode selection rotating switch Overvoltage protection Hot insertion board Environtmental Specifications Operating temperature C Storage temperature C Operating relative humidity % non condensing Mechanical Specifications Size Format Double 7 segment led display for diagnostic indication, watch dog status, master/slave role indication, power supply diagnostic, DualBus lines activity. Double EUROCARD (160 x 233mm) 6U 8TE Product Versions Name Code Features NTA Standard version
3 ITM analog measures board PROCESS INTERFACES ITM microprocessor based board provides 8 insulated analog input, each one based over a 16 bit A/D converter, with high stability and very high disturbance rejection ratio. Each channel can be individually configured, also on the field, allowing the acquisition of low or high voltage level signals, current driven signals, thermocouples or thermo-resistance signals. Microprocessor board providing 8 high insulation and high disturbance rejection analog input. 16 bit converter for each channel Each input individually configurable: providing the choice among voltage, current or resistance driven signals. High common mode and normal mode rejection ratio Redundant board configuration supported Input/Output Analog Input 8 Input signal type Unipolar/bipolar Current Termocouple RTD 3 and 4 wires Input Range Current Type Voltage Type Insulation Dielectric strenght between input and logical circuits Rejection Common mode rejection at 50Hz Normal mode rejection at 50Hz 0 20mA; 0 22mA 0 20mV; 0 40mV; 0 80mV; 0 160mV; 0 320mV; 0 640mV; 0 1,28V; 0 2,56V 0 5V; 0 10V Full between input and logical circuits and between input and input 1500Vrms per 5S ± 2000V peak for 5S > 80 db > 110 db
4 IPRO Overvoltage protection Differential mode input Fast transient 5/50ns 1KVp Pulse 1,2/50µs 1KVp Common mode input A/D Conversion ADC Resolution Total accuracy overall Scanning speed max (16 bit) Power Supply Voltage 5V (±5%) Consumption 150mA Fast transient 5/50ns 1KVp Pulse 1,2/50µs 1KVp 16 bit Better than 0.05% in the C range 16 conversion in a second Caratteristiche ambientali Operating Temperature C Storage Temperature C Operating relative humidity % non condensing Mechanical Specifications Size Format Double EUROCARD (160 x 233mm) 6U 4 or 8TE depending on backpanel module used Product Version Name Code Features ITM Standard Version
5 ITO digital output board PROCESS INTERFACES ITO board provides 16 microprocessor controlled digital outputs, based on medium power optocoupled solid state relays. Before command execution, each solid state relay is tested, besides the digital output current is hardware limited, and monitored by an analog/digital converter. Microprocessor based board providing 16 high insulation and high noise rejection solid state relays digital output Current limit control for each output Automatic diagnostic integrity test for each output solid state relays. Redundant board configuration supported Digital Output Output specification 16 Status and regulation commands Signal type Solid state relays (maximum voltage 60V) Max output current 200mA Protection Short-circuit protection (current limited at 220mA) Insulation Dielectric strenght between output and digital circuits Overvoltage protection Differential mode output Diagnostics Common mode output Full between input and logical circuits 1500Vrms for 5S ± 2000V peak for 5S Fast transient 5/50ns 1KVp Impulso 1,2/50µs 1KVp Fast transient 5/50ns 1KVp Impulso 1,2/50µs 1KVp Digital output integrity test Field connection integrity test Current absorbed by the load
6 IPRO Power supply Tensione 5V (±5%) Assorbimento 50mA Environmental Specifications Temperatura operativa C Temperatura non operativa C Umidità relativa operativa % non condensante Mechanical Specifications Size Format double EUROCARD (160 x 233mm) 6U 4 or 8TE depending on backpanel module used Product Versions Name Code Features ITO Direct interface to the relay terminal block ITO General purpose
7 ITR analog output board PROCESS INTERFACES The ITR board provides 8 analog insulated command output, each with a 16 bit high stability D/A converter. ITR is equipped with diagnostic circuitry that in case of malfunction, cause the disconnection of their output from the field. The ITR can operate in redundant pairs, in which case one of the two ITR cards pilot actuators in the field, while the other is disconnected from it, but ready for going into operation as soon as it detects a malfunction of the supplementary card. Microprocessor based board, that pilot 8 insulated 16 bit output Configurable output type (voltage or current driven) 16 bit D/A converter Accuracy better than 0,15% Redundant board configuration supported Analog output Output number 8 Signal type Voltage - unipolar/bipolar Current - unipolar Input Range Current driven (Rmax=750ohm) Voltage driven (Rmin=1Kohm) Voltage driven (Rmin=2Kohm) Insulation Dielectric strenght between input and digital circuits 0 20mA; 0 24mA; 4-20mA 0 5V; ±(0 5V); 0 10V; ±(0 10V) Conversion DAC Resolution 16 bit Total accuracy Better than 0.1% Full between output and digital circuits 1500Vrms for 5S ± 2000V peak for 5S Power supply Voltage Absorption 5V (±5%); 24V(±5%)
8 IPRO Environmental Specifications Operating temperature C Storage temperature C Relative humidity % non condensing Mechanical Specifications Size Format double EUROCARD (160 x 233mm) 6U 4 or 8TE depending on backpanel module used Versions Name Code Features ITR Standard Version
9 ITS digital input board PROCESS INTERFACES ITS board provides16 insulated digital input. Each input can be individually configured, also on the field, setting the proper range of input voltage. Two of the 16 input (no. 1 and no. 8) can be configured as 8 bit pulse counters. ITS is managed by a microprocessor that is used also for the periodical control of electrical integrity of each input optocouplers. Microprocessor based board providing 16 high insulation and high disturbance rejection digital input; 2 of the signals can be used as pulse counters (hardware managed) Voltage driven input signal from 10Vcc to 125Vcc Input integrity automatic diagnostic Alternative operating modes are available for the acquisition of digital signal as counters (software managed) Redundant board configuration supported Digital status (ITS operating mode) Digital Input Signal type Current absorbed Sampling period Common Polarity The logical status of each input is acquired 16 (2 groups of 8 with common) Wet or dry contacts 12V; 24V; 48V; 110V (±10%) typical 7mA 1ms Positive or negative Counters ( ITT operating mode) The total pulse count on each input is acquired Digital Input 16 Signal type Wet or dry contacts 12V; 24V; 48V; 110V (±10%) Sampling period 1ms Counter register 8 or 16 bit Current absorbed typical 7mA Counters (ITF operating mode) The pulse count in the time unit (second) is acquired Digital Input 16 Signal type Wet or dry contacts 12V; 24V; 48V; 110V (±10%) Sampling period 1ms Counter register 8 or 16 bit Current absorbed typical 7mA
10 IPRO Hardware Managed Counters Counter Input Signal type Insulation Sampling period Current absorbed Filter configuration Dielectric strenght between input and logical circuits Dielectric strenght between input and input Overvoltage protection Differential mode input 2 (in substitution of 2 status signal) Wet or dry contacts 12V; 24V; 48V; 110V (±10%) 1Khz (10Khz for one of the two inputs) typical 7mA 100µs; 200µs; 1ms (selection using jumpers on board) Full between input and logical circuits and between input and input 1500Vrms for 5S ± 2000V peak for 5S 1500Vrms for 5S ± 2000V peak for 5S Fast transient 5/50ns 1KVp Pulse 1,2/50µs 1KVp Diagnostics Common mode input Power Supply Voltage 5V (±5%) Consumption 100mA Fast transient 5/50ns 1KVp Pulse 1,2/50µs 1KVp Environmental Specifications Operating Temperature C Storage Temperature C Operating relative humidity % non condensing Mechanical Specifications Size Format Integrity test of digital input (not available for voltage level of 48V and 110V) Double EUROCARD (160 x 233mm) 6U 4 or 8TE depending on backpanel module used Product Versions Name Code Features ITS Standard Version
11 ISER communication controller PROCESS INTERFACES ISER is a communication board that manages multiple serial lines connecting intelligent peripheral devices. ISER provides different communication protocols over the up to 4 serial lines, transferring the acquired data to the CPU board. Using a couple of ISER boards a redundant link for the 4 serial lines is provided. 16 bit microprocessor 2 asynchronous standard RS232 serial lines (complete with standard PC criteria) galvanic insulated 2 asynchronous standard RS232/RS485serial lines (complete with standard PC criteria) galvanic insulated Overvoltage protection Diagnostics led Processor Type Clock frequency Memory RAM EEPROM FLASH Serial communication Serial line 1 Serial line 2 Serial line 3 Serial line 4 Insulation 80C188XL20 20Mhz 512Kbyte 512Kbyte Standard RS232 Management of all standard provided criteria Standard RS232 Management of all standard provided criteria Standard RS232 or RS485 Management of all RS232 standard provided criteria Half Duplex or Full Duplex management for the RS485 standard Standard RS232 o RS485 Management of all RS232 standard provided criteria Half Duplex or Full Duplex management for the RS485 standard Galvanic between two couples of serial lines (1 and 3 with 2 and 4) and logic elaboration circuits 500Vrms
12 IPRO Diagnostics Power supply Voltage 5V (±5%) Current consumption 500mA Environmental Specifications Operating temperature C Storage temperature C Operating relative humidity % non condensing Mechanical Specifications Size Format Monitoring serial line with test and diagnostics of serial lines proper operation double EUROCARD (160 x 233mm) 6U 8TE Version Name Code Features ISER DualBus Standard version
13 SPW power supply PROCESS INTERFACES SPW is a high performance, microprocessor controlled, power supply used for DualBus DCS systems. The output power can be redundant and is always protected and controlled providing diagnostics information. SPW is available in different versions, to cover all the needs of different power supply: network alternate voltage power supply, continuous voltage power, low voltage or high voltage. Switching power supply with high efficiency, high isolation and fully protected Integrated diagnostics DualBus compatible Versions for network alternate voltage power supply, continuous low voltage power, continuous high voltage power. Redundancy 1+1 e N+1 Microprocessor controlled Version with different output voltage (5V and 24V) Input power supply Voltage 19,6 60Vcc; Vdc; Vac Power factor 0,95 Input Energy hole, without > 50mS per la versione a rete degradation in the output with load > 20mS per le versioni con ingresso in continua at 80% Power output 5V output version 5V 12A 24V output version 24V 5A 5V and 24V output version 5V 6A; 24V 2,5A Ripple <1% Tempo di risposta per variazioni di <20mS carico del 25% Output voltage regulation Microprocessor controller Stability Efficiency Output Voltage variation less than 0,5% for input voltage variation of ±20% Output Voltage variation less than 0,5% for load variation from 10 to 100% Voltage drift < 0,05%/ C Efficiency >85% at 75% of maximum load
14 IPRO Protection Output Voltage Overvoltage and overcurrent protection Input Power Supply Isolamento Dielectric strength input/ground Dielectric strength input/output Dielectric strength output/ground Diagnostics Other features Fuse > 1,5KVrms 50Hz 60s > 2KVrms 50Hz 60s > 500Vrms 50Hz 60s Real time measurement of output voltage level, output state signaled by led, digital transmission of voltage levels values through DualBus; measure of average board temperature with alarm signaling and overtemperature shutdown circuit. Serial port for diagnostics communication Redundancy operation with decoupling low drop diode. Circuito di soft start, e bassa corrente di inrush < 5Inominale per 50mS; Fanless Lifetime at 40 C > 5 yearsi Environmental specification Operating temperature C without derating, at 70 C with derating 3%/ C Storage temperature C Operating relative humidity % non condensino Caratteristiche meccaniche Size Format double EUROCARD (160 x 233mm) 6U 8TE Versions Name Code Features SPW 5-24 hv Input Voltage: Vac/dc Output Voltage: 5V 6A; 24V 2,5A SPW 5 hv Input Voltage: Vac/dc Output Voltage: 5V 12A SPW 24 hv Input Voltage: Vac/dc Output Voltage: 24V 5A SPW 5-24lv Input Voltage 20 60Vac/dc Output Voltage: 5V 6A; 24V 2,5A SPWL 5 lv Input Voltage 20 60Vac/dc Output Voltage: 5V 12A SPW 24 lv Input Voltage: 20 60Vac/dc Output Voltage 24V 5A
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationDCS Series 1 kw, 1.2 kw, & 3 kw
DCS Series 1 kw, 1.2 kw, & 3 kw AVAILABLE WITH LXI STANDARD COMPLIANT ETHERNET Applications Automotive Electronics Rackmount ATE System Battery Charging DCS Series DCS Series: 1 kw, 1.2 kw, & 3 kw DCS
More informationHyperAccess Access Control System
Control System We manufacture, an advanced PC based access control solution that will give you control over who has access to your building. With you can control access on hundreds of doors for up to 10,000
More informationABB RTU560A Series CMU & Modules
ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power
More information6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A
6ES7313-5BF03-0AB0 Page 1 Product data sheet 6ES7313-5BF03-0AB0 SIMATIC S7-300, CPU 313C, COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO 1 PT100, 3 FAST COUNTERS (30 KHZ), INTEGRATED 24V DC POWER SUPPLY,
More informationNEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
More informationTelephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
More informationIsolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give
More informationTURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a
More informationMSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments
The MSITel module family allows your ground console to be everywhere while balloon experiments run everywhere MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments
More informationDS1104 R&D Controller Board
DS1104 R&D Controller Board Cost-effective system for controller development Highlights Single-board system with real-time hardware and comprehensive I/O Cost-effective PCI hardware for use in PCs Application
More informationVersions. Q.station Q.station T. Q.station D. Q.station DT x x
Most important features: Very high data rates up to 100 khz each channel 100 khz at 16 channels, 10 khz at 128 channels 64 Q.bloxx modules connectable Ethernet interface for configuration and data output
More informationZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
More informationSELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)
OBSOLETE NMPD0 Series SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Efficiency (Min.) Power (Max.) V V % W NMPD003C 3. 9.50 NMPD005C 5. 9.5 NMPD0C. 0 0.00 NMPD05C 5. 9 0.00 FEATURES RoHS
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationPowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
More informationAtmel Norway 2005. XMEGA Introduction
Atmel Norway 005 XMEGA Introduction XMEGA XMEGA targets Leadership on Peripheral Performance Leadership in Low Power Consumption Extending AVR market reach XMEGA AVR family 44-100 pin packages 16K 51K
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationProgrammable Controller G Series. New. Models
Programmable Controller G Series The IMO G6 is a very compact modular programmable controller offering extremely high performance. It is ideal for all applications from process control to machine control
More informationM2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit www.advantech.com/products.
M2M I/O Modules 14 M2M I/O Modules Overview 14-2 M2M I/O Modules Selection Guide 14-6 ADAM-2510Z Wireless Router Node 14-8 ADAM-2520Z Wireless Modbus RTU Gateway 14-9 ADAM-2031Z ADAM-2632Z ADAM-2017Z ADAM-2018Z
More information400-800. Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***
INPUT Input protection Thermal protection Switching frequency internal fuse standard 100KHz Input with PFC : (MML400PFC, MML600, MML800) Input voltage range 85*-264VAC Inrush current (peak) MML400PFC
More informationTPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal
Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal Specifications Size: (L122 x W123 x H104 mm) Series Interface: Half duplex RS-485 with transformer
More informationapplicomio Profibus-DP
BradCommunications Profibus-DP network interface cards allow deterministic I/O data acquisition for PC-based control applications. Features New! Support of Windows 32-bit and 64-bit (WoW64) Support of
More informationSCADAPack 530E 535E. remote Programmable Automation Controller
SCADAPack 530E 535E remote Programmable Automation Controller 1 With the SCADAPack 500E range, Schneider Electric introduces the first ever remote Programmable Automation Controller (rpac). This data sheet
More informationFlexible Counter Series in DIN size 24 x 48 mm
Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display 2 different supply voltages available: independent of mains supply with lithium battery
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationModel: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
More informationImpedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
More informationHigh Power Programmable DC Power Supplies PVS Series
Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient
More informationDAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com This handbook has been designed as a guide to the installation and operation of King Pigeon Hi-Tech.Co.,Ltd DAM series. Statements
More informationSOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More informationWP-8849. WinPAC-8x49 Series (WP-8149/8449/8849) is the new generation WinCE based InduSoft PAC (Programmable Automation Controller).
Tu Sitio de Automatización! WP-8149 WP-8449 Introduction: WP-8849 WinPAC-8x49 Series (WP-8149/8449/8849) is the new generation WinCE based InduSoft PAC (Programmable Automation Controller). It equips a
More informationZlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
More informationT200, PTP/IEEE 1588 Grandmaster Clock and
T200, PTP/IEEE 1588 Grandmaster Clock and NTP Time Server with high accuracy GPS receiver, OCXO or Rubidium oscillator 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 1 HEOL-T200 : PERFORMANCE
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationNETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationCAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.
7I29 MANUAL Rev 1.5 CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. THE 7I29 IS INTENDED FOR USE BY OEMS THAT WILL INTEGRATE IT INTO A SYSTEM WITH INTERLOCKS AND
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationComputer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE
Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and
More informationIntelligent RS-485 I/O expansion unit: RU-87Pn Series
INTRODUCTION RU-87Pn series is a remote intelligent I/O expansion unit that used to expand i-87k series I/O modules over the RS-485 for industrial monitoring and controlling applications. There are more
More informationAlcalde # 1822 Col. Miraflores C.P. 44270 Guadalajara, Jal. Mexico MX 01 (33) 3854-5975 y 3823-4349 USA 001 (619)- 884-94-93 (San Diego, CA.
Tu Sitio de Automatización! Description Modbus is very wide known protocol in the industrial manufacturing and environment monitoring fields. It is suit master-slave or query-response distributed I/O applications.
More informationVibration analysis and monitoring Compact. Powerful. Modern technology.
Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More informationOptimize your simple machines... Modicon M218 Selection Guide
Optimize your simple machines... Modicon M218 Selection Guide Compact Solution for Simple Machines Optimized Logic Controller Modicon M218 With intelligent software platform, specialized functional s,
More informationhttp://support.automation.siemens.com/ww/view/en/4067870&td=1
6ES7316-2AG00-0AB0 SIMATIC S7-300, CPU 316 Technical / CAx data nmlkji Technical Data nmlkj CAx data As of 2010-01-24 Power supply Input voltage Rated value (DC) permissible range, lower limit (DC) permissible
More informationRemote Level Monitoring Unit
Remote Level Monitoring Unit SPECIFICATIONS LASER MEASUREMENT Type InGasAs Laser Diode Wavelength 905 nm Beam Divergence 2.3 x 0.2 mrad (typical) Passive Range 0.5m to 150m Range to Reflective Target 0.5m
More informationProgrammable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8
CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection
More informationDocumentation. M-Bus 130-mbx
Documentation M-Bus 130-mbx Introduction The mx M-Bus module is part of the mx Smart Slot communications family. With the integrated SmartSlot technology, mx systems ag offers automatic consumer data read-out
More informationTRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
More informationLEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: len@len.it url: http//www.len.
MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3
More informationSwiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.
Proud Partners with MOBATime GPS or DCF 77 MOBA-NMS (Network Management Sy The new multipurpose time server for the LAN and NTP-based Distributed Time System by MOBATIME DTS 4138.timeserver The DTS 4138.timeserver
More informationCPUs - CPU 315-2 PN/DP
Overview The CPU with a medium program memory and quantity framework High processing performance in binary and floating-point arithmetic Used as a central controller on production lines with central and
More informationTAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
More informationSubstation Automation Products Relion 670/650 series IEC and ANSI Hardware
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common
More informationg9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP
Programmable Safety controllers g9sp G9SP compact Stand-Alone Programmable controller Stand-alone safety controller for small and mid-sized machinery Easy programming for complex safety control Three types
More information4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
More informationDCS Data and communication server
8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With
More informationSilvertel. Ag5200. 1 Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power
Silvertel V1.1 November 2012 Datasheet Pb 1 Features IEEE802.3at and IEEE802.3af compliant Maximum 30W output power Dual In-Line (DIL) package size 50.6mm (L) x 30mm (W) Overload, short-circuit and thermal
More informationIndoor / Outdoor Antenna
z300 High Precision NTP Time Server Indoor / Outdoor Antenna High Precision NTP Time Server with PoE (Indoor or Outdoor use) synchronized by GPS Revision 4 ZTI / 1 boulevard d'armor / BP 20254 / 22302
More information30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
More informationStreamline Your Automation System with M2M Technology
Streamline Your Automation System with M2M Technology Boundless Integration with the ADAM Remote I/O Series In order to meet the integration requirements of Environmental Monitoring Systems and Facility
More informationModular I/O system Rugged Modular I/O System Solutions EN-50155 certified for railway applications
The systems and devices of the MODULAR I/O family are the Tecnint HTE solutions for industrial and technological application of automation, acquisition and management that require particularly robustness
More information1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
More information3500/22M Transient Data Interface
3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery
More informationOPTICAL FIBER repeaters/ isolators
OPTICAL FIBER repeaters/ isolators FUNCTINALITY AND RELIABILITY' Optical Fiber converters give the possibilità to extend on Optical Fiber (also at the same time) every type of network/bus (LAN/Ethernet,
More informationProgettare per il Solid State Lighting: le sfide da superare
Progettare per il Solid State Lighting: le sfide da superare Power supply - Photometry Remote Control Dott. Ing. Stefano Scalzi stefano.scalzi@torand.it www.torand.it Company introduction Target markets
More informationProgrammable Logic Controller PLC
Programmable Logic Controller PLC UPCO ICAI Departamento de Electrónica y Automática 1 PLC Definition PLC is a user friendly, microprocessor based, specialized computer that carries out control functions
More informationOpen Architecture Design for GPS Applications Yves Théroux, BAE Systems Canada
Open Architecture Design for GPS Applications Yves Théroux, BAE Systems Canada BIOGRAPHY Yves Théroux, a Project Engineer with BAE Systems Canada (BSC) has eight years of experience in the design, qualification,
More informationLab Experiment 1: The LPC 2148 Education Board
Lab Experiment 1: The LPC 2148 Education Board 1 Introduction The aim of this course ECE 425L is to help you understand and utilize the functionalities of ARM7TDMI LPC2148 microcontroller. To do that,
More informationCommunication Controller with IP services for leased lines and wireless links Radio Activity S.r.l.
Communication Controller with IP services for leased lines and wireless links Radio Activity S.r.l. Registration CCIAA Milano No. 1728248 P.I./C.F.: 04135130963 Head office and Operational headquarter:
More informationMeasuring Temperature withthermistors a Tutorial David Potter
NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in
More informationProduct Information S N O. Portable VIP protection CCTV & Alarm System 2
Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to
More informationwith Electronic Assistant
TECHNICAL DATASHEET #TDAX100200 BLDC Motor Drive Drives a 12V, 24V or 48V BLDC motor Bidirectional, up to 25A Smooth speed control using Hall Sensors CAN (SAE J1939) with Electronic Assistant Features:
More informationNTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential
More informationRadio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light
Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light In this issue, we would like to present the EnOcean radio sensor module STM 110 in more detail. The module
More information6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0
4 SIMATIC S7-300 Central processing units CPU 312C to CPU 317F-2 DP CPU 317F-2 DP The failsafe CPU with a large program memory and quantity framework for demanding applications For configuration of a failsaf
More informationUSER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More informationUS-SPI New generation of High performances Ultrasonic device
US-SPI New generation of High performances Ultrasonic device Lecoeur Electronique - 19, Rue de Courtenay - 45220 CHUELLES - Tel. : +33 ( 0)2 38 94 28 30 - Fax : +33 (0)2 38 94 29 67 US-SPI Ultrasound device
More informationWEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
More informationDesigned for the needs of automation, telecommunications, remote supervision, and monitoring
- Programmable automation controller (PAC) MADE IN EU is a series of industrial computers which you can easily adapt to your needs by choosing from the available options. Energy-efficient ARM11 700 MHz
More informationDKWF121 WF121-A 802.11 B/G/N MODULE EVALUATION BOARD
DKWF121 WF121-A 802.11 B/G/N MODULE EVALUATION BOARD PRELIMINARY DATA SHEET Wednesday, 16 May 2012 Version 0.5 Copyright 2000-2012 Bluegiga Technologies All rights reserved. Bluegiga Technologies assumes
More informationMILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
More informationFieldbus slave modules with I/Os, DIO
140 Fieldbus slave modules with I/Os, DIO 1534CF00 1534CH00 1534PF00 1534PH00 1536CH00 1536CL10 1536PH00 1536PL00 Order number 1534CF00 1534CH00 1534PF00 1534PH00 Figure Type SM 153, CANopen slave, DIO
More informationCPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
More informationPower network telecommunication
www.siemens.com Power network telecommunication Teleprotection Answers for infrastructure and cities. Binary I/O The best protection against high-voltage grid failures When it comes to managing power networks,
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationTechnical Description. Multifunctional Desk-Top Call Station Digital Version 8, 16 Keys L.No. 1 760 4, 1 761 5
Technical Description Multifunctional Desk-Top Call Station Digital Version 8, 16 Keys L.No. 1 760 4, 1 761 5 Contents 1. General remarks 2. Design 3. Block diagram 4. Function 4.1 Controller system with
More informationSIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2
6ES7315-2AG10-0AB0 Page 1 Product data sheet 6ES7315-2AG10-0AB0 SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2. INTERFACE DP-MASTER/SLAVE
More informationProfibus DP Network with DeltaV/EMERSON Digital Automation System and Ponto Series Remote I/O
Application Note NAP101 Profibus DP Network with DeltaV/EMERSON Digital Automation System and Ponto Series Remote I/O Summary Description...1 1. Introduction...2 2. Installation...3 3. Configuration...3
More information6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A
6ES7314-6CG03-0AB0 Page 1 Product data sheet 6ES7314-6CG03-0AB0 SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED
More informationPonto Series. A new concept for automation
Ponto Series A new concept for automation Programmable Controller Remote I/O for Field Buses Special models of I/O modules Web connection Ponto Series Programmable Controller High connectivity CPUs Direct
More informationopti-s SERIES Data logging - simply smart The optimeas smartlog Family www.optimeas.de
opti-s SERIES Data logging - simply smart The optimeas smartlog Family The optimeas smartlog Family Modern measuring instruments and data logging systems have an increasing number of setting parameter
More information1701/22 FieldMonitor Management Interface Module
1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides
More informationFL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
More informationSimplify Data Acquisition with a Built-in LXI Web Server
M E A S U R E M E N T T I P S Volume 9, Number 3 Simplify Data Acquisition with a Built-in LXI Web Server Snapshot: Make temperature measurements quickly and easily There are many applications in which
More informationDisturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
More information