Supplementary Protectors/Miniature Circuit Breakers
|
|
|
- Valentine Ramsey
- 9 years ago
- Views:
Transcription
1 Technical Data Supplementary Protectors/Miniature Circuit Breakers Catalog Numbers 1492-SP Series C
2 Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at describes some important differences between solid-state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid-state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures. IMPORTANT Identifies information that is critical for successful application and understanding of the product. Allen-Bradley, Rockwell Software, Rockwell Automation, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.
3 Introduction Supplementary Protectors & Accessories Figure SP* Devices & Accessory Overview Accessories Supplementary Protector/Miniature Circuit Breaker 1 Auxiliary/Signal Alarm 1492-ASPHS3 or 142-ASPHSC3 7 Shunt Trip 1492-ASPA1 3 Single-Pole 1492-SP1 Two-Pole 1492-SP2 Dual Auxiliary Contact 1492-ASPHH3 6 Undervoltage Release 1492-ASPU115 4 Three Pole 1492-SP3 Switched Pole Neutral Protector 2 Auxilliary Contact 1492-ASPH3 5 ➀ Supplementary Protector/Miniature Circuit Breaker Available in single-, two-, three-pole, one-pole neutral, and four-pole neutral Specifications & Certifications: Meets UL 1077/CSA 22.2 No. 235 In conformity with IEC/EN CE Marked Trip Characteristics B-Trip for resistive or slightly inductive loads C-Trip for inductive loads D- Trip for highly inductive loads ➁ Switched Pole Protector (not field-mountable) Switched neutral pole closes before the adjacent protected pole (i.e., early make) Instantaneous/magnetic release provided, but no overload thermal release Rockwell Automation Publication 1492-TC010D-EN-P April
4 ➂ Shunt Trip Field installable Mounts to side Module width is equal to that of a single-pole ➃ Undervoltage Release Field installable Mounts to side Module width is equal to that of a single-pole ➄ Auxiliary Contact Field installable Changeover contact Switches when protective device is operated manually or is tripped electrically 1 Form C ➅ Dual Auxiliary Contact Field installable Two auxiliary contacts Changeover contact Switches when protective device is operated manually or is tripped electrically 2 Form C Version with convertible contact ➆ Auxiliary/Signal Alarm Field installable Auxiliary contacts Auxiliary contact switches when protective device is operated manually or is tripped electrically Signal alarm Signal alarm contact switches only when protective device is tripped electrically Changeover contact 2 Form C Front indicator indicates when device is tripped electrically 4 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
5 Description Bulletin 1492-SP Supplementary Protector/Miniature Circuit Breakers are energy limiting, thermal-magnetic type, overcurrent-protective devices meeting UL 1077/CSA 22.2 No. 235, IEC/EN and IEC These devices are designed for the protection of a wide variety of products including: Solenoids Test Equipment Controller I/O Points Relay and Contractor Coils Computers Transformers Automotive Systems Power Supplies Medical Equipment Control Instrumentation Bulletin 1492-SP Supplementary Protectors/Miniature Circuit Breakers are available in one-, two-, three-, and four-pole units as well as one- and three-pole plus neutral units. One- and two-pole AC units also have limited DC ratings. Two and three-pole units are connected at the handle for simultaneous operation. Screw termination is standard on all Bulletin1492-SP units. Both line and load side terminals accept #16 4 AWG ( mm 2 ) copper wire. IMPORTANT UL 1077, CSA C22.2 No. 235 In North America, miniature circuit breakers are recognized as supplementary protectors and are intended for use as overcurrent protection within an appliance or other electrical equipment where branch circuit protection is already provided or not required. Internationally, these products are rated to IEC standards as miniature circuit breakers for equipment. Rockwell Automation Publication 1492-TD010D-EN-P April
6 International Approvals The Bulletin 1492-SP, Supplementary Protectors/Miniature Circuit Breakers, are designed to comply with standards for worldwide customer acceptance. The Bulletin 1492-SPs meet the following standards:. Table 1 - Bulletin 1492-SP Standards Certifying Agency Certification Marks Country Standard Underwriters Laboratory USA UL 1077 Canadian Standards Association Canada CSA 22.2 No. 235 Verband Deutscher Electrotechniker Germany IEC/EN Germanischer Lloyd Germany IEC/EN per Conformite European European Union IVD Directives per International Electrotechnical Commission Global IEC IEC China Quality Certification Center Global GB Rockwell Automation Publication 1492-TD010D-EN-P April 2011
7 Features The following features provide superior performance. Table 2 - Features of Bulletin 1492-SP Feature Energy limiting design Field mountable options True IP2X finger safe design (front) International approvals Ratings to 480Y/277V 240/415V AC AC and DC voltage ratings A positively trip-free mechanism Three trip curves Time delay (D characteristic) Superior shock and vibration resistance capabilities Mounts on DIN Rail Reversible line and load connections Description protects downstream components better than conventional breakers during short circuits for selective applications CE Marked and meets UL, CSA, and IEC (VDE, GL) standards for worldwide acceptance 10,000 A Interrupt Rating in one convenient device where the breaker operation cannot be defeated by holding the handle in the ON position B, C, and D for high inrush currents during inductive startups, such as transformers and power supplies helps to prevent nuisance tripping Rockwell Automation Publication 1492-TD010D-EN-P April
8 Construction Figure 2 - Construction Screw Termination accepts #16...#4 ( mm 2 ) wire as standard Front View Convenient Terminals for commoning links and bus bars (both line and load side) Positively Trip-Free Mechanism Nylon Body provides toughness and durability required by the environment Ease of Installation & Replacement easily snaps on and off of DIN rail Flag Indicator is clearly marked for position in both international and domestic indication green OFF and red ON Amperage Rating is clearly marked on the front of the device for easy identification Finger Safe to IEC Front Variety of Pole Options available in one-, two-, or three-pole and one- or three-pole neutral Side View Catalog Number Prefix Current & Voltage Ratings Approval Symbols Switched Neutral Module (not field-mountable) The switched neutral module opens the neutral line of the circuit when the protected poles are tripped. This module should be used as a safety measure (required by some standards) when protecting networks with a grounded neutral system. The switched neutral pole closes before the adjacent protected pole (i.e., early make). The switched neutral module also provides instantaneous/magnetic trip, manual actuation is through the linked handles, and should always be mounted on the right side of the protected poles. These modules are not field installable. 8 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
9 Ordering Information To order the proper device, you need to know the: maximum rated current of equipment to be protected, system phase of one, two, or three, maximum startup (inrush) current, and accessories that are required. Catalog Number Determine the catalog number by following the steps below and referencing the Selection Tables on page Select a one-, two-, or three-pole device. 2. If needed, select the Switched Neutral Module. The Switched Neutral Module is mounted on the right side of the breaker. This module must be mounted at the factory. It cannot be installed in the field. 3. If applicable, consider the derating factors listed in the Rating Determination on page Order accessory contacts or modules as separate items. Accessory modules are always mounted on the left side of the supplemental protector/ miniature circuit breaker. A maximum of two accessory modules can be mounted on a single device. Refer to the Accessories on page 18 for possible combinations. Rating Determination The standard tripping characteristic for Bulletin 1492-SP is Type C. Type C has a magnetic trip activated at 5 10 times the rated current of the circuit breaker. The reference temperature for the thermal tripping characteristics is 30 C. The Type C characteristic will suit most applications. Use the following steps to determine the current rating for the breaker. 1. Take the rated current of the equipment. For example, 10 A. 2. Take the ambient temperature of the 1492-SP location (e.g., 50 C (122 F)). 3. Refer to the table below, which rerates the 1492-SP current for the given ambient temperature. Influence of the ambient temperature on the thermal tripping characteristic. Rockwell Automation Publication 1492-TD010D-EN-P April
10 Table 3 - Ambient Temperature Derating Calibration temperature = 30 C; application below 0 C is for non-condensing atmosphere* Product Nameplate Continuous Current Rating Ambient Temperature in C *Care should be taken for application below 0 C. These devices are not certified to operate correctly in the presence of ice. 4. All other specifications for standard Bulletin1492-SP products remain unchanged. The ambient temperature derating applies to applications of the device as an IEC Miniature Circuit Breaker (MCB) following and as a supplementary protector to UL1077/CSA 22.2 No 235. Ambient temperature refers to the free air temperature in contact with the 1492-SP. Contact Rockwell Automation for ambient temperatures beyond those shown above. 5. Select the 1492-SP with the next available rating at the given ambient temperature. In this example, it would be 13 A. With this selection, adequate overload protection is provided and nuisance tripping by thermal influences is avoided. 6. Check that transients of the system do not exceed the must hold value of the trip characteristic. This will eliminate nuisance tripping by magnetic influences. The Type C characteristic will be adequate for most applications. Refer to the Selection Tables on page Rockwell Automation Publication 1492-TD010D-EN-P April 2011
11 7. In rare occurrences when the Type C characteristic does not fully meet the application, the following additional magnetic trip characteristics are available: 8. Type D allows for transients approximately twice as high as the standard Type C. Refer to the Selection Tables on page Type B achieves instantaneous tripping at current levels approximately half as high as Type D. Refer to the Selection Tables on page If multiple supplementary protectors are mounted side-by-side, they must be derated to determine the load carrying capacity. Use the derating equation below. Adjusted Current Rating = Rated Current multiplied by α The figure below shows the rated diversity factor, where miniature circuit breakers influence one another thermally at rated load. Figure 3 - Rated Diversity Factor 1.00 Rated Diversity Factor Number of Circuit Breakers Rockwell Automation Publication 1492-TD010D-EN-P April
12 Selection Tables B-Trip Characteristics Resistive/Slightly Inductive Loads, 3 5 I n Table 4 - One Pole & One-Pole Neutral One-Pole One-Pole plus Neutral Continuous Current Catalog 3rd Party Continuous Current Catalog 3rd Party Rating (In) Number Certification Rating (In) Number Certification SP1B010 ➊ SP1B010-N ➊ SP1B020 ➊ SP1B020-N ➊ SP1B030 ➊ SP1B030-N ➊ SP1B040 ➊ SP1B040-N ➊ 5 ➋ 1492-SP1B050 ➊ SP1B060 ➊ SP1B060-N ➊ 7 ➋ 1492-SP1B070 ➊ SP1B080 ➊ SP1B080-N ➊ SP1B100 ➊ SP1B100-N ➊ SP1B130 ➊ SP1B130-N ➊ 15 ➋ 1492-SP1B150 ➊ SP1B160 ➊ SP1B160-N ➊ SP1B200 ➊ SP1B200-N ➊ SP1B250 ➊ SP1B250-N ➊ 30 ➋ 1492-SP1B300 ➊ SP1B320 ➊ SP1B320-N ➊ SP1B400 ➊ SP1B400-N ➊ SP1B500 ➊ SP1B500-N ➊ SP1B630 ➊ SP1B630-N ➊ Operational Voltage IEC 240/415V AC/48V DC IEC 240V AC UL/CSA 277V AC/48V DC UL/CSA 277V AC Pieces Per Package 2 1 Diagram N N ➊ ➋ Current rating used only in North America. 12 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
13 Table 5 - Two-Pole, Three-Pole, & Three-Pole Neutral Two-Pole Three-Pole Three-Pole plus Neutral Continuous Current Rating (In) Catalog Number 3rd Party Certification Continuous Current Rating (In) Catalog Number 3rd Party Certification Continuous Current Rating (In) Catalog Number SP2B010 ➊ SP3B010 ➊ SP3B010-N ➊ SP2B020 ➊ SP3B020 ➊ SP3B020-N ➊ SP2B030 ➊ SP3B030 ➊ SP3B030-N ➊ SP2B040 ➊ SP3B040 ➊ SP3B040-N ➊ 5 ➋ 1492-SP2B050 ➊ 5 ➋ 1492-SP3B050 ➊ SP2B060 ➊ SP3B060 ➊ SP3B060-N ➊ 7 ➋ 1492-SP2B070 ➊ 7 ➋ 1492-SP3B070 ➊ SP2B080 ➊ SP3B080 ➊ SP3B080-N ➊ SP2B100 ➊ SP3B100 ➊ SP3B100-N ➊ SP2B130 ➊ SP3B130 ➊ SP3B130-N ➊ 15 ➋ 1492-SP2B150 ➊ 15 ➋ 1492-SP3B150 ➊ SP2B160 ➊ SP3B160 ➊ SP3B160-N ➊ SP2B200 ➊ SP3B200 ➊ SP3B200-N ➊ SP2B250 ➊ SP3B250 ➊ SP3B250-N ➊ 30 ➋ 1492-SP2B300 ➊ 30 ➋ 1492-SP3B300 ➊ SP2B320 ➊ SP3B320 ➊ SP3B320-N ➊ SP2B400 ➊ SP3B400 ➊ SP3B400-N ➊ SP2B500 ➊ SP3B500 ➊ SP3B500-N ➊ SP2B630 ➊ SP3B630 ➊ SP3B630-N ➊ 3rd Party Certification Operational Voltage Pieces per Package IEC 415V AC IEC 415V AC IEC 415V AC UL/CSA 480Y/277V AC, 96V DC UL/CSA 480Y/277V AC UL/CSA 480Y/277V AC Diagram DC N N ➊ ➋ Current rating used only in North America. Rockwell Automation Publication 1492-TD010D-EN-P April
14 C-Trip Characteristics Inductive Loads, 5 10 I n Table 6 - One Pole & One-Pole Neutral One-Pole One-Pole plus Neutral Continuous Current Rating (In) Catalog Number 3rd Party Certification Continuous Current Rating (In) Catalog Number SP1C005 ➊ SP1C005-N SP1C010 ➊ SP1C010-N ➊ SP1C020 ➊ SP1C020-N ➊ SP1C030 ➊ SP1C030-N ➊ SP1C040 ➊ SP1C040-N ➊ 5 ➋ 1492-SP1C050 ➊ SP1C060 ➊ SP1C060-N ➊ 7 ➋ 1492-SP1C070 ➊ SP1C080 ➊ SP1C080-N ➊ SP1C100 ➊ SP1C100-N ➊ SP1C130 ➊ SP1C130-N ➊ 15 ➋ 1492-SP1C150 ➊ SP1C160 ➊ SP1C160-N ➊ SP1C200 ➊ SP1C200-N ➊ SP1C250 ➊ SP1C250-N ➊ 30 ➋ 1492-SP1C300 ➊ SP1C320 ➊ SP1C320-N ➊ SP1C400 ➊ SP1C400-N ➊ SP1C500 ➊ SP1C500-N ➊ SP1C630 ➊ SP1C630-N ➊ Operational Voltage IEC 240/415V AC/48V DC IEC 240V AC UL/CSA 277V AC/48V DC UL/CSA 277V AC Pieces Per Package 2 1 3rd Party Certification Diagram N N ➊ ➋ Current rating used only in North America. 14 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
15 Table 7 - Two-Pole, Three-Pole, & Three-Pole Neutral Two-Pole Three-Pole Three-Pole plus Neutral Continuous Current Rating (In) Catalog Number 3rd Party Certification Continuous Current Rating (In) Catalog Number 3rd Party Certification Continuous Current Rating (In) Catalog Number SP2C005 ➊ SP3C005 ➊ SP3C005-N ➊ SP2C010 ➊ SP3C010 ➊ SP3C010-N ➊ SP2C020 ➊ SP3C020 ➊ SP3C020-N ➊ SP2C030 ➊ SP3C030 ➊ SP3C030-N ➊ SP2C040 ➊ SP3C040 ➊ SP3C040-N ➊ 5 ➋ 1492-SP2C050 ➊ 5 ➋ 1492-SP3C050 ➊ SP2C060 ➊ SP3C060 ➊ SP3C060-N ➊ 7 ➋ 1492-SP2C070 ➊ 7 ➋ 1492-SP3C070 ➊ SP2C080 ➊ SP3C080 ➊ SP3C080-N ➊ SP2C100 ➊ SP3C100 ➊ SP3C100-N ➊ SP2C130 ➊ SP3C130 ➊ SP3C130-N ➊ 15 ➋ 1492-SP2C150 ➊ 15 ➋ 1492-SP3C150 ➊ SP2C160 ➊ SP3C160 ➊ SP3C160-N ➊ SP2C200 ➊ SP3C200 ➊ SP3C200-N ➊ SP2C250 ➊ SP3C250 ➊ SP3C250-N ➊ 30 ➋ 1492-SP2C300 ➊ 30 ➋ 1492-SP3C300 ➊ SP2C320 ➊ SP3C320 ➊ SP3C320-N ➊ SP2C400 ➊ SP3C400 ➊ SP3C400-N ➊ SP2C500 ➊ SP3C500 ➊ SP3C500-N ➊ SP2C630 ➊ SP3C630 ➊ SP3C630-N ➊ 3rd Party Certification Operational Voltage Pieces per Package Diagram IEC 415V AC IEC 415V AC IEC 415V AC UL/CSA 480Y/277V AC, 96V DC UL/CSA 480Y/277V AC UL/CSA 480Y/277V AC DC N N ➊ ➋ Current rating used only in North America. Rockwell Automation Publication 1492-TD010D-EN-P April
16 D-Trip Characteristics Highly Inductive Loads I n Table 8 - One Pole & One-Pole Neutral One-Pole One-Pole plus Neutral Continuous Current Rating (In) Catalog Number 3rd Party Certification Continuous Current Rating (In) Catalog Number SP1D005 ➊ SP1D005-N SP1D010 ➊ SP1D010-N ➊ SP1D020 ➊ SP1D020-N ➊ SP1D030 ➊ SP1D030-N ➊ SP1D040 ➊ SP1D040-N ➊ 5 ➋ 1492-SP1D050 ➊ SP1D060 ➊ SP1D060-N ➊ 7 ➋ 1492-SP1D070 ➊ SP1D080 ➊ SP1D080-N ➊ SP1D100 ➊ SP1D100-N ➊ SP1D130 ➊ SP1D130-N ➊ 15 ➋ 1492-SP1D150 ➊ SP1D160 ➊ SP1D160-N ➊ SP1D200 ➊ SP1D200-N ➊ SP1D250 ➊ SP1D250-N ➊ 30 ➋ 1492-SP1D300 ➊ SP1D320 ➊ SP1D320-N ➊ SP1D400 ➊ SP1D400-N ➊ SP1D500 ➌ SP1D500-N ➌ SP1D630 ➌ SP1D630-N ➌ Operational Voltage IEC 240/415V AC/48V DC IEC 240V AC UL/CSA 277V AC/48V DC UL/CSA 277V AC Pieces Per Package 2 1 3rd Party Certification Diagram N N ➊ ➋ Current rating used only in North America. ➌ 16 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
17 Table 9 - Two-Pole, Three-Pole, & Three-Pole Neutral Two-Pole Three-Pole Three-Pole plus Neutral Operational Voltage Pieces per Package Continuous Current Rating (In) Catalog Number 3rd Party Certification Continuous Current Rating (In) Catalog Number 3rd Party Certification Continuous Current Rating (In) Catalog Number SP2D005 ➊ SP3D005 ➊ SP3D005-N ➊ SP2D010 ➊ SP3D010 ➊ SP3D010-N ➊ SP2D020 ➊ SP3D020 ➊ SP3D020-N ➊ SP2D030 ➊ SP3D030 ➊ SP3D030-N ➊ SP2D040 ➊ SP3D040 ➊ SP3D040-N ➊ 5 ➋ 1492-SP2D050 ➊ 5 ➋ 1492-SP3D050 ➊ SP2D060 ➊ SP3D060 ➊ SP3D060-N ➊ 7 ➋ 1492-SP2D070 ➊ 7 ➋ 1492-SP3D070 ➊ SP2D080 ➊ SP3D080 ➊ SP3D080-N ➊ SP2D100 ➊ SP3D100 ➊ SP3D100-N ➊ SP2D130 ➊ SP3D130 ➊ SP3D130-N ➊ 15 ➋ 1492-SP2D150 ➊ 15 ➋ 1492-SP3D150 ➊ SP2D160 ➊ SP3D160 ➊ SP3D160-N ➊ SP2D200 ➊ SP3D200 ➊ SP3D200-N ➊ SP2D250 ➊ SP3D250 ➊ SP3D250-N ➊ 30 ➋ 1492-SP2D300 ➊ 30 ➋ 1492-SP3D300 ➊ SP2D320 ➊ SP3D320 ➊ SP3D320-N ➊ SP2D400 ➊ SP3D400 ➊ SP3D400-N ➊ SP2D500 ➌ SP3D500 ➌ SP3D500-N ➌ SP2D630 ➌ SP3D630 ➌ SP3D630-N ➌ IEC 415V AC IEC 415V AC IEC 415V AC UL/CSA 480Y/277V AC, 96V DC UL/CSA 480Y/277V AC UL/CSA 480Y/277V AC Diagram DC N 3rd Party Certification N ➊ ➋ Current rating used only in North America. ➌ Rockwell Automation Publication 1492-TD010D-EN-P April
18 Accessories Table 10 - Auxiliary Contacts Auxiliary Contact Description Approvals Diagram Auxiliary Contact Module Changeover 1 Form C Switches when protective device is operated manually or tripped electrically Catalog Number 1492-ASPH3 Dual Auxiliary Contact Module Two auxiliary contacts Changeover contact 2 Form C Switches when the protective device is operated manually or tripped electrically ASPHH3 Auxiliary/Signal Alarm Module Auxiliary Contact switches when the protective device is operated manually or tripped electrically Signal Alarm Contact trip indicating contact switches only when the protective device is tripped electrically Changeover Contact 2 Form C Front Indicator signals when device is tripped electronically Convertible Contact Module Customer selectable Contact sets similar to 1492-ASPHH3 or ASPHS3 Customer may field select one configuration or the other ASPHS ASPHSC3 18 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
19 Table 11 - Voltage Trips Voltage Trip Description Approvals Diagram Voltage Undervoltage Release Module Use to trip the adjacent breaker poles when the applied voltage is less than the nominal voltage Undervoltage trip is often used when loss of power and eventual restoration of power creates an unsafe or unknown set of conditions U < D1 D V AC V AC Catalog Number 1492-ASPU ASPU230 Shunt Trip Module Use to trip the adjacent breaker poles from a remote location. The module is actuated by applying a voltage (pickup voltage) to the trip terminals Use in emergency shutdown circuits where multiple power circuits must be switched off from a single location V AC V DC V AC 12 60V DC 1492-ASPA ASPA2 Rockwell Automation Publication 1492-TD010D-EN-P April
20 Allowable Combinations of Field Added Modules IMPORTANT All field added modules must be added to left side of supplementary protector/miniature circuit breaker. Table 12 - Allowable Combinations of Field Added Modules + Catalog Number Catalog Number ASPHSC3 ASPH3 ASPHH3 ASPHS3 ASPA ASPU SP* X X X X X X X X X X X X X X X X X X X X X X X X (1) Auxiliary Contact Module (1) Dual Auxiliary Contact Module (1) Auxiliary/Signal Alarm Contact Module (1) Convertible Contact Module (1) Shunt Trip Module (1) Undervoltage Release Module (1) Auxiliary Contact Module + (1) Shunt Trip Module (1) Dual Auxiliary Contact Module + (1) Shunt Trip Module (1) Auxiliary/Signal Alarm Module + (1) Shunt Trip Module (1) Convertible Contact Module + (1) Shunt Trip Module 20 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
21 Additional Accessories The following table lists additional accessories used with all 1492-SP* Miniature Circuit Breakers. Table 13 - Additional Accessories Accessory Mounting Rails Catalog Number Pieces per Package 1 m Symmetrical DIN 199-DR m Hi-Rise Symmetrical DIN 1492-DR6 2 1 m Angled Hi-Rise Symmetrical DIN 1492-DR7 2 End Anchor 1492-EAH35 50 Lockout Attachment 1492-ASPLOA 10 Product Selection Cuttable Copper Bus Bar NOTE: The copper bus bar is 1 meter in length and may be cut to a length suitable for your application. Figure 4 - Bus Bar Specifications Bus Bar Description Devices per Meter Amperage Approvals Catalog Number Single-Phase UL 508 A1B UL E56639 Category A1B1 36 with 80 NMTR2 A1B8H Auxiliary ULus listed Module 100 CE A1B1H Two-Phase A2B8 22 with Auxiliary Module 100 A2B1 80 A12B8H 100 A12B1H Three-Phase A3B8 16 with Auxiliary Module 100 A3B1 80 A3B8H 100 A3B1H Package Quantity Rockwell Automation Publication 1492-TD010D-EN-P April
22 Table 14 - Bus Bar Accessory Specifications Accessory Description Amperage Approvals Figure 5 - Bus Bar Installation Catalog Number End Caps for Single-Phase Bus Bar UL 508 A1E 10 use with: UL E56639 Two- & Three-Phase Bus Bar Category AME Protective Shroud NMTR2 AAP Terminal Lug 80/100 ULus Listed CE AAT1 Package Quantity * Ampacity of Devices Z2 AWG lb-in Nm SP... or 1492-FB AAP 4 mm AWG lb-in Nm AAT1 22 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
23 Table 15 - Bus Bar Installation Specifications Type Number of 1492-SP* Rated Operational I e : End Feed per Phase Center Feed per Phase (I e < 63 A) Approvals Catalog Number Fork Style Commoning Links may be cut to length, not for use with accessories One-Pole 1 m ASPCL1 1 (56 devices/m) Three-Pole 1 m ASPCL3 1 (19 devices/m) End Cap for Three-Pole ASPEC1 10 Fork Style Commoning Links may NOT be cut to length, not for use with accessories One-Pole ASPCL102 6 ASPCL ASPCL Two-Pole ASPCL (One-Pole plus Neutral) 3 ASPCL ASPCL Three-Pole ASPCL ASPCL Four-Pole ASPCL ASPCL412 5 Fork-Style Commoning Links (for use with accessories) One-Pole ASPCL1A02 20 Two-Pole (One-Pole plus Neutral) 6 ASPCL1A06 9 ASPCL1A ASPCL1A ASPCL1A06 5 ASPCL1A10 Three-Pole ASPCL3A ASPCL3A12 Three-Phase Bus Bar for Multiple One-Pole (each with one auxiliary contact) 2x3 (1p) ASPCL3AP x3 (1p)+2 (1p) ASPCL3AP x3 (1p) ASPCL3AP09 10 Incoming Terminals for Fork Style (not for use in North America) Pieces per Package For Max 25 mm 2 Wire For Max 25 mm 2 Wire 100 ASPCT ASPCLT35 10 Protective Covers for Unused Forks ASPCLPS 10 sets (5 per set) Rockwell Automation Publication 1492-TD010D-EN-P April
24 Technical Information Limiting Let-Through Energy Bulletin 1492-SP versus Conventional Breakers The 1492-SP line features the unique ability to achieve short-circuit interruptions far more effectively than conventional breakers. In conventional circuit breakers, the short-circuit interruption time required is approximately one or two half cycles of an AC sine wave. When the contacts open, the resulting arc continues to burn until the current level passes through zero. The arc may reignite because of the insufficient width of the contact gap. The current that flows until the arc is extinguished produces a heating effect proportional to the I 2 t value (let-through-energy) of the fault current. The 1492-SP device is designed to substantially reduce the amount of letthrough-current and the resulting let-through-energy that can damage protected components. The 1492-SP has the ability to interrupt short-circuit current within the first half cycle of the fault. Limiting let-through-energy will protect against the harmful effects of overcurrent and is focused primarily on avoiding: excessive heat and mechanical damage. Both of these factors are proportional to the square of the current. Thermal energy is proportional to the square of the RMS value and magnetic forces are proportional to the square of the peak value. The most effective way to provide protection is to substantially limit let-through-energy. This provides the following advantages: Far less damage at the location of the short circuit. Fast electric separation of a faulty unit from the system; in particular, power supplies connected in parallel that are switched off when the voltage of the power bus drops below a certain level. Far less wear on the miniature circuit breaker itself, which means more safe interruptions. Better protection of all components in the short circuit path. Far wider range of selective action when used with an upstream protective device; there are no nuisance shut downs from feeder line interruptions, causing a blackout in all connected branches. 24 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
25 Short-Circuit Interruption The following graphic shows the short circuit interruption from 10 ka 120V AC with an instant of initiation of 15 after a voltage of zero. Figure 6 - Short-Circuit Interruption Conventional Breakers 10 ka 120V AC Instant of Initiation: 15 After Voltage Zero Current Voltage Across Breaker A B C Time A B C Maximum Arc Voltage Recovery Voltage A = instant when the short is initiated B = instant when the contacts open and the arc is initiated C = instant when the arc extinguishes and the current ceases to flow 79,000 A 2 s Let-Though I 2 t 3,500 A 2 s Rockwell Automation Publication 1492-TD010D-EN-P April
26 Energy-Limiting Characteristics Tripping Characteristics Figure 7 - Tripping Characteristics at 30º C Time in Seconds I / I N ➊ Conventional Non-Tripping Current: 1 nt =1.13I N : t >1h ➋ Conventional Tripping Current: 1t=1.45: t <1h ➌ 2.55I N : t=1-60 seconds (I N < 32a); t=1-120 seconds (I N < 32a) ➍ Type B: 31 N : t > 0.1 seconds ➎ Type B: 51 N : t < 0.1 seconds ➏ Type C: 51 N : t > 0.1 seconds ➐ Type C: 101 N : t < 0.1 seconds ➑ Type D: 101 N : t > 0.1 seconds ➒ Type D: 201 N : t < 0.1 seconds 26 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
27 Specifications Table 16 - Basic Specifications Description B Curve C Curve D Curve Tripping Characteristic Poles (17 mm width per pole) Resistive or Slightly Inductive Loads, 3 5 I n 1, 2, 3, 1+ N, 3 + N Approvals See Selection Tables on page 12 Maximum Voltage Dielectric Strength Shock Vibration Operating Temperature Range Shipment & Short-Term Temperature Limits Wire Size (Cu Only) Housing Material #18 8 AWG ( mm 2 ) #6 4 AWG (16 25 mm 2 ) Recommended Wire Strip Length Electromechanical Life Switched Neutral Rating Direction of Incoming Supply Contact Position Indicator Terminals Mounting Mounting Position 1960V AC Inductive Loads, Highly Inductive 5 10 I n Loads, I n 25 G Half Sine Wave for 11 ms (3 axes) Frequency Range: Hz Max. Amplitude (p - p) = in. Max. Acceleration = 5 G 2 hours each of 3 axes F ( C) non-condensing F ( C) Nylon Tightening Torque: 2.4 N m (21 lb-in.) Tightening Torque: 3.1 N m (27 lb-in.) 0.51 in. (13 mm) 6,000 operations (1 operation = 2 switching events) ON/OFF 277V AC As Required Red/Green M5 (with slotted screw PZ2) DIN Rail (IEC60715) As Required Rockwell Automation Publication 1492-TD010D-EN-P April
28 Table 17 - Basic Specifications, Continued Description B Curve C Curve D Curve Current Range 1 63 A A A Certifications Use Group (UG) Terminals (FW) Overload Rating One-Pole, One-Pole plus Neutral UL 1077 Recognized Component QVNU2 - E65138 CSA 22.2 No. 235 Certified Components UG A General Industrial FW 3 Line and Load Evaluated for Field Wiring OL 0 (General Use) Maximum Voltage 277V AC 48V DC Tripping Current (TC) TC1, 40 C Short-Circuit Current Rating (SC) SC U2 SCU1 <35 A V AC; B & C Curve 5 277V AC; D Curve 40, 50, 63 A 5 277V AC; B, C, & D Curve Two-Pole, Three-Pole, Three-Pole plus Neutral 10 48V DC; B, C, & D Curve Maximum Volts 480Y/277V AC 96V DC (Two-Pole Series) Tripping Current (TC) TC2, 40 C Short-Circuit Current Rating SC U2 SC U1 Miniature Circuit Breakers <35 A V AC; B & C Curve 5 480V AC; D Curve 40, 50, 63 A 5 277V AC; B, C, & D Curve 10 48V DC; B, C, & D Curve Current Range 1 63 A A A Certifications Electrical Specifications IEC/EN (VDE) IEC/EN (GL) (not including D50 and D63) CQC (GB-10963) (not including D50 and D63) Rated Voltage Un 240/415 VAC 48 V DC (CE ) Rated Insulation Voltage Ui 440 V AC Rated Impulse Withstand Voltage U imp 4 kv (1.2/50) Conventional Non-Tripping Current Conventional Tripping Current int=1.13 In it=1/45 In Reference Temperature 30 C Temperature Factor Maximum Back-Up Fuse Selectivity Class 3 Rated Short-Circuit Capacity Service Short-Circuit Capacity Climatic Conditions 0.5% per K 125 A gl/gg Icn (IEC )=10 ka Icu (IEC )=15 ka Ics=7.5 ka Acc to IEC 68-2 (25 55 C/90 95% RH) 28 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
29 Auxiliary Contacts Module Type Catalog Number Degree of Protection Auxiliary Contact, Dual Auxiliary Contact, Auxiliary /Signal Alarm Undervoltage Release Shunt Trip ASPH3, ASPHH3, ASPHS3, ASPHSE3 ASPU115, ASPU230 ASPA1, ASPA 2 IP 20 (IP 00) Dimensions See Dimensions on page 31. Weight in kg Mechanical Lifespan in Operations Minimum Impulse Duration Minimum Command Time Operating Voltage 6,000 10,000 4,000 > 15 ms 200 ms ASPU115 U n - 115V AC U min - 50V AC ASPU230 U n - 230/240V AC U min - 110V AC ASPA1 ASPA2 Inrush Current 3.6/44 ma (AC/DC) 25/12 ma (AC) 15/2 ma (DC) Dropout x U s V AC V DC V AC 12 60V DC Voltage Range x U s IEC UL 1077, CSA 22.2 No. 235 Maximum Operating Current Terminal Capacity IEC Rigid, CU Tightening Torque Maximum Operating Current Terminal Capacity CU Tightening Torque 250V AC 3 A 250V AC 0.5 A 110V DC 0.5 A U min - 5V AC mm mm mm 2 2 x x 2.5 mm 2 2 x x 2.5 mm 2 2 x x 4.0 mm Nm 1.1 Nm V AC 2 110V DC 0.5 A U min - 5 V DC #18 #14 AWG 2 x #18 2x #14 AWG #18 #14 AWG 2 x #18 2x #14 AWG 7 lb-in. 10 lb-in. 21 lb-in. #18 #8 AWG 2 x #18 2x #12 AWG Rockwell Automation Publication 1492-TD010D-EN-P April
30 Ampacity in Amps Ampacity in Amps Application Information A bus bar may be used for all 1492-SP Miniature Circuit Breakers. IMPORTANT Position high current drawing devices nearest to the Feed Terminal, 1492-AAT1. Figure 8 - For 1492-ANNN Bus Bars * Ampacity of Devices Z2 AWG lb-in Nm SP... or 1492-FB AAP 4 mm AWG lb-in Nm AAT1 Figure 9 - Temperature Current Characteristic 100 Ampacity of 1492-A_B8_Bus Bar Temperature in Celsius 100 Ampacity of 1492-A_B1_Bus Bar Temperature in Celsius 1492-FB 1492-SP 30 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
31 LISTED 3HXJ For use with 1492-FB: 80A/600V AC, 100kA RMS Sym.Amps SCCR w/175a J Fuse, 600V AC, max. For use with 1492-SP: 80A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. LISTED 3HXJ LISTED 3HXJ Made in Germany LISTED 3HXJ LISTED 3HXJ For use with 1492-FB: 80A/600V AC, 100kA RMS Sym.Amps SCCR w/175a J Fuse, 600V AC, max. For use with 1492-SP: 80A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. LISTED 3HXJ Made in Germany Dimensions Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes. Figure SP Series C Figure 11 - Bulletin 1492-A1B x 17.8 = A1B8 Ser. A 1492-A1E 1492-A1B8 Ser. A 1492-A1E Figure 12 - Bulletin 1492-A2B (23) AME 1492-A2B8 Ser. A For use with 1492-FB: 80A/600V AC, 100kA RMS Sym.Amps SCCR w/175a J Fuse, 600V AC, max. For use with 1492-SP: 80A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany x 17.8 = AME 1492-A2B8 Ser. A For use with 1492-FB: 80A/600V AC, 100kA RMS Sym.Amps SCCR w/175a J Fuse, 600V AC, max. For use with 1492-SP: 80A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany Figure 13 - Bulletin 1492-A3B AME 1492-A3B8 Ser. A For use with 1492-FB: 80A/600V AC, 100kA RMS Sym.Amps SCCR w/175a J Fuse, 600V AC, max. For use with 1492-SP: 80A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany 56.0 x 17.8 = AME 1492-A3B8 Ser. A For use with 1492-FB: 80A/600V AC, 100kA RMS Sym.Amps SCCR w/175a J Fuse, 600V AC, max. For use with 1492-SP: 80A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany Rockwell Automation Publication 1492-TD010D-EN-P April
32 LISTED 3HXJ For use with 1492-FB: 100A/600V AC, 100kA RMS Sym.Amps SCCR w/200a J Fuse, 600V AC, max. For use with 1492-SP: 100A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. LISTED 3HXJ LISTED 3HXJ For use with 1492-FB: 100A/600V AC, 100kA RMS Sym.Amps SCCR w/200a J Fuse, 600V AC, max. For use with 1492-SP: 100A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. LISTED 3HXJ For use with 1492-FB: 80A/600V AC, 100kA RMS Sym.Amps SCCR w/175a J Fuse, 600V AC, max. For use with 1492-SP: 80A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany Made in Germany Made in Germany LISTED 3HXJ LISTED 3HXJ For use with 1492-FB: 100A/600V AC, 100kA RMS Sym.Amps SCCR w/200a J Fuse, 600V AC, max. For use with 1492-SP: 100A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. LISTED 3HXJ For use with 1492-FB: 100A/600V AC, 100kA RMS Sym.Amps SCCR w/200a J Fuse, 600V AC, max. For use with 1492-SP: 100A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. LISTED 3HXJ For use with 1492-FB: 80A/600V AC, 100kA RMS Sym.Amps SCCR w/175a J Fuse, 600V AC, max. For use with 1492-SP: 80A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany Made in Germany Made in Germany Figure 14 - Bulletin 1492-A1B x 17.8 = A1B1 Ser. A 1492-A1E A1B1 Ser. A 1492-A1E Figure 15 - Bulletin 1492-A2B AME 1492-A3B1 Ser. A For use with 1492-FB: 100A/600V AC, 100kA RMS Sym.Amps SCCR w/200a J Fuse, 600V AC, max. For use with 1492-SP: 100A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany 1492-AME 1492-A3B1 Ser. A For use with 1492-FB: 100A/600V AC, 100kA RMS Sym.Amps SCCR w/200a J Fuse, 600V AC, max. For use with 1492-SP: 100A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany x 17.8 = Figure 16 - Bulletin 1492-A1B1H x 27.0 = A1B1H Ser. A 1492-A1E 1492-A1B1H Ser. A 1492-A1E Figure 17 - Bulletin 1492-A1B8H x 27.0 = A1B8H Ser. A 1492-A1E 1492-A1B8H Ser. A 1492-A1E 32 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
33 LISTED 3HXJ LISTED 3HXJ LISTED 3HXJ LISTED 3HXJ LISTED 3HXJ LISTED 3HXJ Figure 18 - Bulletin 1492-A2B8H AME 1492-A2B8H Ser. A For use with 1492-FB: 80A/600V AC, 100kA RMS Sym.Amps SCCR w/175a J Fuse, 600V AC, max. For use with 1492-SP: 80A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max Made in Germany 22.0 x 44.5 = AME 1492-A2B8H Ser. A For use with 1492-FB: 80A/600V AC, 100kA RMS Sym.Amps SCCR w/175a J Fuse, 600V AC, max. For use with 1492-SP: 80A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany Figure 19 - Bulletin 1492-A3B8H AME 1492-A3B8H Ser. A For use with 1492-FB: 80A/600V AC, 100kA RMS Sym.Amps SCCR w/175a J Fuse, 600V AC, max. For use with 1492-SP: 80A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany 1492-AME 1492-A3B8H Ser. A For use with 1492-FB: 80A/600V AC, 100kA RMS Sym.Amps SCCR w/175a J Fuse, 600V AC, max. For use with 1492-SP: 80A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany x 17.8 = x 62.3 = Figure 20 - Bulletin 1492-A2B1H AME 1492-A2B1H Ser. A For use with 1492-FB: 100A/600V AC, 100kA RMS Sym.Amps SCCR w/200a J Fuse, 600V AC, max. For use with 1492-SP: 100A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany 22.0 X 44.0 = AME 1492-A2B1H Ser. A For use with 1492-FB: 100A/600V AC, 100kA RMS Sym.Amps SCCR w/200a J Fuse, 600V AC, max. For use with 1492-SP: 100A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany Rockwell Automation Publication 1492-TD010D-EN-P April
34 LISTED 3HXJ LISTED 3HXJ Figure 21 - Bulletin 1492-A3B1H AME 1492-A3B1H Ser. A For use with 1492-FB: 100A/600V AC, 100kA RMS Sym.Amps SCCR w/200a J Fuse, 600V AC, max. For use with 1492-SP: 100A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany 1492-AME 1492-A3B1H Ser. A For use with 1492-FB: 100A/600V AC, 100kA RMS Sym.Amps SCCR w/200a J Fuse, 600V AC, max. For use with 1492-SP: 100A/480V AC, 10kA RMS Sym.Amps SCCR, 480V AC, max. Made in Germany X 17.8 = X 62.3 = Figure 22 - Auxiliary Contacts 1492-ASPHH3, ASPHS3, ASPH3, AS9HSC3P Figure 23 - Undervoltage Release Module 1492-ASPU Figure 24 - Shunt Trip Module 1492-ASPA Rockwell Automation Publication 1492-TD010D-EN-P April 2011
35 LISTED 1492-AAT1 Ser. A 3HXJ M4 Hex Screw Figure 25 - Bus Bar Accessories Bulletin 1492-A1E Bulletin 1492-AME Bulletin 1492-AAT For use with 1492-FB and 1492-SP 100A/600V AC Wire Range: 10-1/0 AWG Torque: 50 lb-in. 3.0 Ø Bulletin 1492-AAP x 17.8 = Rockwell Automation Publication 1492-TD010D-EN-P April
36 Internal Resistance The following table provides the internal resistance of a one-pole at room temperature. Table 18 - Internal Resistance of a One-Pole at Room Temperature R [mω]* I n [A] Type B Type C Type D * 50 Hz 36 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
37 Power Loss I n Entire Unit Table 19 - Entire Unit Power Loss I n Type B, C, & D Type B P* [W] Type C P* [W] Type D P* [W] I n [A] 1p 1pN 2p 3p 3pN 1p 1pN 2p 3p 3pN 1p 1pN 2p 3p 3pN * 50 Hz Rockwell Automation Publication 1492-TD010D-EN-P April
38 Maximum Let-Through Energy IEC/EN Figure 26 - Type B Let-Through Current I 2 t [A 2 sec] B8 B6, B7 B5 B4 B50, B63 B40 B30, B32 B20 B25 B15, B16 B10 B13 B3 B B Prospective Short-Circuit Current [A] Rockwell Automation Publication 1492-TD010D-EN-P April 2011
39 Figure 27 - Type C C63 C50 C40 C30, C32 C25 C20 C10 C13 C15, C16 Let-Through Current I 2 t [A 2 sec] C7, C8 C6 C5 C4 C3 C C1 C Prospective Short-Circuit Current [A] Rockwell Automation Publication 1492-TD010D-EN-P April
40 Figure 28 - Type D D63 D50 D40 D30, D32 D20 D25 D13 D10 D7, D8 Let-Through Current I 2 t [A 2 sec] D6 D5 D4 D3 D2 D D Prospective Short-Circuit Current [A] 40 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
41 Maximum Let-Through Current IEC/EN Figure 29 - Type B B5 B63 B50 B40 B32 B16 B20 B25, B30 B13, B15 B10 B8 B6, B B4 B3 Let-Through Current I [A] DL B2 500 B Prospective Short-Circuit-Current I [A] CC Rockwell Automation Publication 1492-TD010D-EN-P April
42 Figure 30 - Type C C50, C63 C32, C40 C25,C30 C20 C15, C16 C10, C13 C8 C6, C7 C5 C4 C3 Let-Through Current I [A] DL C2 500 C1 C Prospective Short-Circuit-Current I [A] Rockwell Automation Publication 1492-TD010D-EN-P April 2011
43 Figure 31 - Type D Let-Through Current I [A] DL D63 D50 D40 D30,D32 D20 D16 D25 D13 D10 D7,D8 D6 D5 D4 D3.5 D3 D2.5 D2 D1.5 D D Prospective Short-Circuit-Current I [A] Rockwell Automation Publication 1492-TD010D-EN-P April
44 44 Rockwell Automation Publication 1492-TD010D-EN-P April 2011
45
46 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit Installation Assistance If you experience a problem within the first 24 hours of installation, review the information that is contained in this manual. You can contact Customer Support for initial help in getting your product up and running. United States or Canada Outside United States or Canada Use the Worldwide Locator at or contact your local Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Outside United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process. Please contact your local Rockwell Automation representative for the return procedure. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat: İçerenköy, İstanbul, Tel: +90 (216) Publication 1492-TD010D-EN-P April Supersedes Publication 1492-TD010C-EN-P - March 2002 Copyright 2011 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
Bulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
Bimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
Molded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Circuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
Product Guide. Cable-in / cable-out miniature circuit breakers and supplementary protectors
Product Guide Cable-in / cable-out miniature circuit breakers and supplementary protectors Cable-in / cable-out miniature circuit breakers and supplementary protectors Eaton offers a complete line of
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P
Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources
Circuit Breakers Supplementary Protectors Manual Motor Controllers
WHITE PAPER Circuit Breakers Supplementary Protectors Manual Motor Controllers Circuit Protection Methods Differentiating between Supplementary Protection, Branch Circuit Protection, and Self-Protected
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
System pro M compact Miniature Circuit Breaker S 200/S 200 M
Data Sheet System pro M compact Miniature Circuit Breaker S 200/S 200 M 2CDC021023S0012 2CDC021038S0012 The miniature circuit breakers of the System pro M compact series S 200 and S 200 M provide state-of-the-art
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
Micro800 Programmable Controllers. Bulletin 2080 Selection Guide
Micro800 Programmable Controllers Bulletin 2080 Selection Guide Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety
Rotary Disconnect Switch Specifications
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)
Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
SMC -3 Specifications
Technical Data SMC -3 Specifications Bulletin Number 150 Topic Page Product Overview 2 Standards Compliance and Certifications 2 Features 3 Catalog Number Explanation 4 Wiring Diagrams 6 General Specifications
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
Catalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
Technical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
1756 ControlLogix Chassis Specifications
Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,
Circuit Breaker. Description
Data Bulletin 0739DB9901R11/03 Cedar Rapids, Iowa, USA International Miniature Circuit Breakers with QO Plug-on and Bolt-on Connections Class Number 0739 Retain for future use. GENERAL DESCRIPTION The
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
ControlNet Standard and High-flex Coax Cable
Installation Instructions ControlNet Standard and High-flex Coax Cable Catalog Number 1786-RG6/A and 1786-RG6F/B About This Document This document contains application information you need to consider
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
USB-to-Data Highway Plus Cable
Installation Instructions USB-to-Data Highway Plus Cable Catalog Number 1784-U2DHP Topic Page Important User Information 2 Environment and Enclosure 3 Install the Cable 5 Configure the DH+ Node Address
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
The complete range of consumer switchboards and switchgear
Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial
Type: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
D-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
Tmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data
Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Installation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter.
Installation Instructions Differential Air-pressure Transmitter Catalog Numbers 1414-IPZ10FODAA, 1414-IPZ10FNDAA, 1414-IPD10FNRAA, 1414-CPZ10FODAA, 1414-CPZ10FNDAA, 1414-CPD10PNRAA Topic Page Before Installation
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade
Installation Instructions SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade Catalog Numbers 1747-DU501 Topic Page System Requirements 3 Install ControlFLASH 3 Prior to Running ControlFLASH
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
MicroLogix 1100 Embedded Web Server
User Manual MicroLogix 1100 Embedded Web Server Bulletin 1763 Controllers Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment.
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600
Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600 Data Bulletin 0600DB1104 03/2012 Retain for future use. Electronic Trip Circuit Breaker Basics 0600DB1104 Table of Contents
AP/UP, AP/MIL Series. Magnetic Circuit Protectors
AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction Poles Configurations Operating Characteristics Delay Curves Specifications Decision Tables 71 72 75 76 77 78 79 AP/UP, AP/MIL Series Hydraulic
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
Sentron Series Circuit Breakers
Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
PowerFlex Dynamic Braking Resistor Calculator
Application Technique PowerFlex Dynamic Braking Resistor Calculator Catalog Numbers 20A, 20B, 20F, 20G, 22A, 22B Important User Information Solid-state equipment has operational characteristics differing
Manual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A
Short-circuit current rating (SCCR) of industrial control panels NEC Article 409 and UL 508A Short-circuit current rating (SCCR) of industrial control panels 1 Introduction 2 Overview of NEC Article 409
PSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
Technicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA
w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Universal Serial Bus (USB) to DH-485 Interface Converter
Installation Instructions Universal Serial Bus (USB) to DH-485 Interface Converter Catalog Number 1747-UIC Contents Overview..................................................3 Computer and Operating System
BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES
The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
Stratix 5700 Network Address Translation. Quick Start
Stratix 5700 Network Address Translation Quick Start Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines
How To Protect A Motor From Overcurrent
Phase ailure elays Type PS and PD Class 8430 Catalog 04 CONTENTS Description.....................................................Page Product Description and Definitions......................................
Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
