Stack Sampling Stack sampling or source sampling
|
|
|
- Anabel Francis
- 9 years ago
- Views:
Transcription
1 Stack Monitoring
2 Stack Sampling Stack sampling or source sampling may be defined as a method of collecting representative samples of pollutant laden air/gases at the place of origin of pollutants to determine the total amount of pollutants emitted into the atmosphere from a given source in a given time
3 Stack Sampling The purpose of stack sampling is to determine emission levels from plant processes to ensure they are in compliance with any emission limits set by regulatory authorities to prevent macro environmental pollution.
4 Stack Sampling Stack sampling is used for the assessment of the following: 1. To determine the quantity and quality of the pollutant emitted by the source. 2. To measure the efficiency of the control equipment by conducting a survey before and after installation 3. To determine the effect on the emission due to changes in raw materials and processes. 4. To compare the efficiency of different control equipments for a given condition. 5. To acquire data from an innocuous individual source so as to determine the cumulative effect of many such sources. 6. To compare with the emission standards in order to assess the need for local control
5 Stack Sampling Source sampling is carried out in a process ventilation stack to determine the emission rates/or characteristics of pollutants. Planning the study: Familiarity of the process and operations to determine the time of cyclic operations, peak loading that might cause variations in the characteristics. Method of sampling Method of analysis of samples Sampling time because certain industries undergo cyclic changes Amount of sample required Sampling frequency
6 Stack Sampling Representative sample: Sample collected must truly represent the conditions prevailing inside the stack. The important considerations for accurate representative sample collection include: Accurate measurement of pressure, moisture, humidity and gas composition The selection of suitable locations for sampling Determination of the traverse point required for a velocity and temperature profile across the cross section of the stack and sampling for particulate matter
7 Schematic Diagram Sampling Train
8 Stack Sampling Sampling System: Stack sampling is carried out by diverting a part of the gas stream through a sampling train of which a general arrangement is shown below Nozzle 2 Sampling probe 3 Particulate collector 4 Gas collector 5 Gas flow meter 6 Flow control valve 7 To vacuum pump
9 Stack Sampling The train consists of a nozzle placed in the gas stream, a sampling probe through which the sample is drawn at different traverses, particulate and gas collection devices, a flow measuring device and a prime mover such as a vacuum pump or an ejector. Nozzle: It is at the end of the probe is sharp edged, pointing inward from the outside edge and the traversing probe is made of stainless steel with glass or Teflon lining.
10 Stack Sampling For Sampling hot gases whose temperature are above C, these probes are provided with a circulating coolant system to prevent combustion of particulate materials inside the probe and to prevent the temperature from exceeding the maximum allowable temperature of filtration materials. Devices: Collection of particulates: Filtration, wet or dry impingement, impaction, electrostatic and thermal precipitation Collection of gases: Absorption, adsorption, freeze out Flow measurement: Use rotameter or orifice meter or dry gas meter if the information on the total volume of the gas sampled is required.
11 Particulates sampling Iso kinetic Sampling Isokinetic stack particulate sampling is conducted to obtain a representative particulate stack sample independent of particle size. To achieve this, the gas stream entering the collector should have a velocity (speed and direction) equal to that of the gas stream just ahead of the sampling port of the collector.
12 Iso kinetic Sampling Webster's dictionary defines ISO as denoting equality, similarity, uniformity. Kinetic is defined as due to motion. Isokinetic sampling is an equal or uniform sampling of particles and gases in motion within the stack. Isokinetic source sampling is achieved when the velocity of gas entering the sampling nozzle is exactly equal to the velocity of the approaching gas stream. This provides a uniform, unbiased sample of the pollutants being emitted by the source.
13 Different conditions 1. Sample collection Velocity (V) > Stack gas velocity (W) 2. Sample collection Velocity (V) < Stack gas velocity (W) 3. Sample collection Velocity (V) = Stack gas velocity (W)
14 Super-ISOKINETIC Condition (V) > (W) If the collection velocity is too high heavy particles fail to adhere to the flow lines and end up by-passing the probe, thereby under-estimating large particles.
15 Sub-ISOKINETIC Condition (V) < (W) If the sample collection velocity is too low heavy particles can enter the probe even if the flow line on which they were located passes by the probe. Thus too many large particles are collected.
16 ISOKINETIC Condition (V) = (W) When conducting isokinetic sampling all particles flowing toward the intake opening are equally collected.
17 Reference Method for Source Testing: Measurement of Releases of Particulate from Stationary Sources Method A: Determination of Sampling Site and Traverse Points Method B: Determination of Stack Gas Velocity and Volumetric Flow Rate Method C: Determination of Molecular Weight by Gas Analysis Method D: Determination of Moisture Content Method E: Determination of Particulate Releases Method F: Calibration Procedure for S-Type Pitot Tube, Dry Gas Meter and Orifice Meter
18 Minimum requirement of a stack monitoring equipment Particulate Sampling : 2 30 lpm collection on thimble type filter up to 0.3 micron rating Gaseous sampling : lpm collection in a set of Borosilicate glass impingers Rotameter : Rotameters:0 to 60 lpm for particulate monitoring and 0 to 3 lpm for gaseous monitoring. Filter Holder : Fabricated from SS 304 tube suitable to hold either cellulose filtration thimble or glass micro fibre thimble
19 Nozzles : A set of 3 stainless steel nozzles Digital clock : 0-60 minutes, 1 second readout with start and stop switches Impinger Sampling Train : 2 No. of 240 ml capacity and 3 No. of 120 ml capacity borosilicate glass impingers with Ball socket joints accommodated in ice tray, made out of FRP, placed on the rear side of instrument panel with a provision of keep ice Vacuum Pump : Monoblock Rotary Vane type, oil lubricated, 0.5 HP single phase motor (230V) with more than 50 lpm free flow capacity
20 Thermocouple: Thermocouple sensor shall be provided with analog or digital dial gauge capable of measuring temperature from 0 to C covered with stainless steel or mild steel casing with acid resistant treatment. Manometer: To measure differential pressure Pitot tube: Pitot tube shall be modified S- type fabricated from SS 304 or equivalent grade. The construction feature should be as per United States Environmental Protection Agency (EPA) regulation, Method 2, Given in Figures 1.1 and 1.2 (A) ii. The construction feature shall be such that the coefficient of the pitot tube is above 0.95.
21 Pitot Tube
22 Method A: Determination of Sampling Site and Traverse Points Applicability Principle Location of Sampling Site Determination of Traverse Points Location of Traverse Points Confirmation of Cyclonic and Reverse Flow
23 Applicability This method is applicable to flowing gas streams in stacks or ducts. The method is not applicable as written when one or more of the following conditions exist: 1. Stack or duct diameters less than 0.30 m (1.0 ft); 2. non-circular or non-rectangular stacks or ducts; and 3. Sampling site less than two stack or duct diameters downstream from a flow disturbance, or less than 0.5 stack or duct diameter upstream from a flow disturbance. 4. cyclonic flow 5. reverse flow
24 Location of Sampling Site Select a site in a straight section of stack located at least eight stack diameters downstream and two stack diameters upstream of any flow disturbance such as a bend, expansion, contraction, visible flame, junction, or stack exit. Size of sampling point: 7-10 cm
25 Determination of Traverse Points When the sampling site is located at least eight diameters downstream and two diameters upstream from a flow disturbance, the required minimum number of traverse points for a circular or rectangular cross section is determined from Table A-1.
26 Table A-1: Minimum Number of Traverse Points for Sampling Sites that Meet the Eight- and Twodiameter Criteria Stack or Duct Diameter (m) Required Minimum Number of Traverse Points Circular Duct Rectangular Duct > to
27 Minimum no. of Traverse point for sampling sites Inside Dia. of Stack (m) Number of Points I.D <= <= I.D >= <= I.D >= <= I.D >= <= I.D >= 5 32
28 Determination of Traverse Points When the eight- and two-diameter criteria cannot be satisfied, the minimum number of traverse points is determined either from Figure A-1 for particulate sampling or from Figure A-2 for velocity measurement.
29 Figure A-1: Minimum Number of Traverse Points for Particulate Sampling
30 Figure A-2: Minimum Number of Traverse Points for Velocity Measurement
31 Location of Traverse Points on Circular and Rectangular Cross Sections Divided into Twelve Equal Areas
32 Location of Traverse Points in Circular Stacks
33 Method B: Determination of Stack Gas Velocity and Volumetric Flow Rate The average gas velocity in a stack or duct is determined from the gas density and from the measurement of velocity pressure with an S-type pitot tube. A standard pitot tube may be used where plugging of the tube openings due to particulate matter and/or moisture is not likely to occur. Stack gas volumetric flow rate is determined from measurements of stack gas velocity, temperature, absolute pressure, dry gas composition, moisture content, and stack diameter.
34 Determination of gas composition: Gas composition can be determined by Orsat apparatus. The gas is collected in the Orsat apparatus and analyzed for the composition of CO 2, O 2 and CO in the same order and the remaining is assumed to be nitrogen. Molecular weight of gas = Σ M x B x Where M x = Molecular weight of CO 2, O 2 and CO and N 2 (44, 32, 28 and 28 respectively) and B x represent % of gases
35 Determination of moisture Content: The moisture content in the stack may be determined by any one of the following methods: Wet bulb and dry bulb temperature technique (Moisture content is less than 18 % and dew point is less than 51 0 C and can not be used for acid stream) Condenser technique Silica gel tube
36 Determination of Temperature: The temperature has to be measured across the crosssection of the stack at predetermined traverse point. The temperature probe is inserted into the stack and the readings are taken with the help of a pyrometer. Types of probe Temperature range, 0 C Chromel/Alumel Copper/Constantan Iron/Constantan Platinum / Platinum % & Rhodium
37 S-type Pitot Tube and Manometer Assembly
38 Velocity Traverse Data Sheet
39 Calculations Absolute stack gas pressure at the sampling site is calculated using equation Actual stack gas velocity at each traverse point is calculated using equation. The average stack gas volumetric flow rate on a dry basis at reference conditions is calculated using equation.
40 Typical sampling provision
41 Preparation of the Sampling Train
42
43
44 Steps for Stack Sampling Procedure for particulate matter sampling 1. Determine the gas composition and correct to moisture content. 2. Determine the temperature and velocity at each traverse point. 3. Determine the empty weight of the thimble (W 1 ). 4. Mark out the traverse points on the probe. The marks are normally fixed by tying with asbestos thread. 5. Check all points for leakages. 6. Determine the flow rate to be sampled under isokinetic condition.
45 Steps for Stack Sampling Procedure for particulate matter sampling 7. Insert the probe at the traverse point 1, very close to the stack. Start the pump and adjust the flow so that the rotameter reads the predetermined value. 8. Switch ff the pump at the end of sampling time. 9. Read the vacuum at the dry gas meter (DGM) and also the temperature. 10. Move the probe to subsequent traverse points by repeating the steps five to eight. 11. After completion of collection of samples, remove the probe and allow it to cool.
46 Steps for Stack Sampling Procedure for particulate matter sampling 12. Remove the thimble carefully. Some of the dust would have adhered to the nozzle. This should be removed by trapping and transferred to the thimble. 13. Weight the thimble with the sample. The difference in weight gives the dust collected. 14. The volume of sample collected in either given by the dry gas meter (m 3 ) or by sampling rate given by rotameter multiplied by the sampling time. 15. Hence from (13) and (14), the emission rate can be calculated. This will be at DGM conditions. This is to be corrected for temperature and pressure so as to obtain values for standard conditions.
47 Sample recovery: Steps for Stack Sampling After cooling, the outside of probe assembly is cleaned with cotton waste. Disconnect the nozzle. Remove the thimble and keep it in a clean glass beaker. The particulate matter adhered to the inside walls of the nozzle, should be transferred carefully to the thimble. Weigh the thimble with sample (W 2 ). The difference in weight (W 2 - W 1 ) will give the particulate collected
48 Sample recovery: Steps for Stack Sampling After cooling, the outside of probe assembly is cleaned with cotton waste. Disconnect the nozzle. Remove the thimble and keep it in a clean glass beaker. The particulate matter adhered to the inside walls of the nozzle, should be transferred carefully to the thimble. Weigh the thimble with sample (W 2 ). The difference in weight (W 2 - W 1 ) will give the particulate collected
(a) Method 1 Sample and Velocity Traverses for Stationary Sources.
While we have taken steps to ensure the accuracy of this Internet version of the document, it is not the official version. Please refer to the official version in the FR publication, which appears on the
CHAPTER- 1 STACK MONITORING MATERIAL AND METHODOLOGY FOR ISOKINETIC SAMPLING
CHAPTER- 1 STACK MONITORING MATERIAL AND METHODOLOGY FOR ISOKINETIC SAMPLING 1 Method-1 (Part- I) CHAPTER-1 Stack Monitoring Material and Methodology for Isokinetic Sampling 1.0 SOURCE EMISSION MONITORING
Spreadsheet Program for EPA Method 202 Condensible Particulate Matter Emission Rate and Concentration Calculations
Spreadsheet Program for EPA Method 202 Condensible Particulate Matter Emission Rate and Concentration Calculations This spreadsheet calculates flue gas concentrations of condensible particulate matter(cpm)
Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance
Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance The Boiler MACT, 40 CFR 63, Subpart DDDDD, was vacated in 2007 by the U.S Court of Appeals and the 2004 rule
Method 202 Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources. By: Paul Ottenstein
Air Quality Issues in the Rocky Mountain Region PM2.5 Source Testing Method 201A Determination PM 10 and PM 2.5 Emissions from Stationary Sources (Constant Sampling Rate Procedure) Method 202 Dry Impinger
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Dr. J. M. Meyers Dr. D. G. Fletcher Dr. Y. Dubief 1. Introduction Last lab you investigated flow loss in a pipe due to the roughness
Chapter 3.5: Fans and Blowers
Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist
Air Quality Performance Test Guidelines. Kansas Department of Health and Environment Bureau of Air and Radiation
Air Quality Performance Test Guidelines Kansas Department of Health and Environment Bureau of Air and Radiation December 22, 2004 TABLE OF CONTENTS 1. INTRODUCTION 2. TEST PLANNING 2.1 EPA Test Methods
(a) Method 1 Sample and velocity traverses for stationary sources.
While we have taken steps to ensure the accuracy of this Internet version of the document, it is not the official version. Please refer to the official version in the FR publication, which appears on the
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain
Monitoring of Total Suspended Particles & Toxic Gasses in Stationary Combustion Systems
ENGINEER - Vol. XXXXIV, No. 04, pp, [36-44], [37-45], 2011 The Institution of Engineers, Sri Lanka Monitoring of Total Suspended Particles & Toxic Gasses in Stationary Combustion Systems K T Jayasinghe
Chapter 12 Industrial Ventilation
Chapter 1 Industrial Ventilation Introduction Industrial Ventilation is an important method for reducing employee exposures to airborne contaminants. Ventilation is used to reduce or remove contaminates
Examination syllabuses for Manual Stack emissions monitoring. Environment Agency Version 9 January 2015
Examination syllabuses for Manual Stack emissions monitoring Environment Agency Version 9 January 2015 Record of amendments Version Date Section Amendment number 6 August 09 Level 1 Updated Level 1 syllabus
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
1.0 What Are the Purpose and Applicability of Performance Specification 11?
While we have taken steps to ensure the accuracy of this Internet version of the document, it is not the official version. Please refer to the official version in the FR publication, which appears on the
Medical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
6 Crankcase Ventilation
6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................
Laboratory Manual for Air Quality Sampling and Analysis
Laboratory Manual for Air Quality Sampling and Analysis Department of Civil Engineering Indian Institute of Technology Delhi New Delhi-110016 MONITORING OF RESPIRABLE PARTICULATE MATTER 1. Objective Sampling
VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes. Accurate airflow measurement for demanding applications
VOLU-probe/SS Stainless Steel Pitot Airflow Traverse Probes Accurate airflow measurement for demanding applications VOLU-probe/SS The VOLU-probe/SS Stainless Steel Pitot Airflow Traverse Probe is ideally
INTRODUCTION. Fact Sheet: Air Pollution Emission Control Devices for Stationary Sources
Fact Sheet: Air Pollution Emission Control Devices for Stationary Sources INTRODUCTION Stationary sources of air pollution emissions, such as power plants, steel mills, smelters, cement plants, refineries,
PROCESS PARTICLE COUNTER (PPC) SENSOR/CONTROLLER FOR OPTIMIZING POWER RECOVERY EXPANDER AND GAS TURBINE PERFORMANCE
PROCESS PARTICLE COUNTER (PPC) SENSOR/CONTROLLER FOR OPTIMIZING POWER RECOVERY EXPANDER AND GAS TURBINE PERFORMANCE APPLICATIONS NOTE FOR MEASUREMENTS AT THE ENTRANCE AND EXIT OF A THIRD STAGE SEPARATOR
HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED
HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED General Air Type P Hydryer Heat Regenerative Systems Introduction General Air Type P Hydryers are electric heat regenerative dryers, designed
SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater
SALES SPECIFICATION SC7640 Auto/Manual High Resolution Sputter Coater Document Number SS-SC7640 Issue 1 (01/02) Disclaimer The components and packages described in this document are mutually compatible
F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems
F ox W hi t e Paper Reduce Energy Costs and Enhance Emissions Monitoring Systems A Technical White Paper from Fox Thermal Instruments Rich Cada, VP Sales & Marketing, Fox Thermal Instruments, Inc. 399
Experiment (13): Flow channel
Introduction: An open channel is a duct in which the liquid flows with a free surface exposed to atmospheric pressure. Along the length of the duct, the pressure at the surface is therefore constant and
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
STATE OF COLORADO PORTABLE ANALYZER MONITORING PROTOCOL
STATE OF COLORADO PORTABLE ANALYZER MONITORING PROTOCOL Determination of Nitrogen Oxides, Carbon Monoxide and Oxygen Emissions from Natural Gas-Fired Reciprocating Engines, Combustion Turbines, Boilers,
HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999
CONTAMINATION CONTROL in hydraulic systems in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further information.
FORMATION DAMAGE AND WELL TREATMENT SYSTEM
FORMATION DAMAGE AND WELL TREATMENT SYSTEM FDWTS-10K Includes ability to test Liquid Permeability & Gas Permeability Fines migration & critical velocity Static Filtration Drilling mud invasion evaluation
*Note: This document is an electronic (scanned) version of the original paper report and formatting may vary somewhat from the original.
Guideline No. 97-05 January 19, 1998 Version 1.0 Guideline for Stack Sampling Facilities* Prepared By: Kevin Reeve, B. Sc. Air Emission Specialist Environmental Operations Division Art Schultz, C.E.T.
SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE
1 Which tool is used to correct internal hi-low when preparing a 4-in. steel pipe for welding? A. 4-in. grinder with cutting disc. B. Mini-grinder with flapper disc. C. Pencil grinder with cone stone.
Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any
Chapter 10 Flow Measurements Material from Theory and Design for Mechanical Measurements; Figliola, Third Edition Flow Rate Flow rate can be expressed in terms of volume flow rate (volume/time) or mass
Testing methods applicable to refrigeration components and systems
Testing methods applicable to refrigeration components and systems Sylvain Quoilin (1)*, Cristian Cuevas (2), Vladut Teodorese (1), Vincent Lemort (1), Jules Hannay (1) and Jean Lebrun (1) (1) University
Thermal Dispersion Mass Flow
Thermatel Thermal Dispersion Mass Flow Measurement Handbook Table of Contents Introduction...1 What is Mass Flow Measurement?...1 Types of Flow Transmitters...4 Differential Pressure...4 Orifice...4 Venturi...6
Vacuum. How It Relates to Refrigeration And Air Conditioning Service
Vacuum How It Relates to Refrigeration And Air Conditioning Service Moisture In A Refrigeration System Visible Moisture Water Droplets Uncommon, but it can occur Invisible Moisture Water Vapor Found in
A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
Averaging Pitot Tubes; Fact and Fiction
Averaging Pitot Tubes; Fact and Fiction Abstract An experimental investigation has been undertaken to elucidate effects of averaging stagnation pressures on estimated velocities for pressure averaging
Engine Heat Transfer. Engine Heat Transfer
Engine Heat Transfer 1. Impact of heat transfer on engine operation 2. Heat transfer environment 3. Energy flow in an engine 4. Engine heat transfer Fundamentals Spark-ignition engine heat transfer Diesel
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS 2009 Tecumseh Products Company. All rights reserved. Page 1 of 8 Refrigerant R22 is widely used for residential and commercial air conditioning, as
DUST EMISSION MONITORING SYSTEM
Applications Measurement of dust concentration in dry or moist, steamsaturated and corrosive stack gases Monitoring of municipal and hazardous waste and sewage sludge incinerators Monitoring of power plants
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES
191: Calibration and Standards in Measurement Richard Paton National Engineering Laboratory, Scotland, UK 1 General Principles 1 2 Gravimetric Calibration of Liquid meters 2 3 Volumetric Calibration of
AABC Specifications for Testing and Balancing HVAC Systems
AABC Specifications for Testing and Balancing HVAC Systems The Associated Air Balance Council (AABC) Total System Balancing Specifications for HVAC Testing, Balancing and Performance Verification TOTAL
Soil Suction. Total Suction
Soil Suction Total Suction Total soil suction is defined in terms of the free energy or the relative vapor pressure (relative humidity) of the soil moisture. Ψ = v RT ln v w 0ω v u v 0 ( u ) u = partial
Pulverized Coal Pipe Testing and Balancing
Pulverized Coal Pipe Testing and Balancing By Richard F. (Dick) Storm, PE The first step in optimizing combustion system performance is balancing the air and fuel flowing through each of the plant's coal
1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
ON-VEHICLE INSPECTION
Sight Glass I11244 ONVEHICLE INSPECTION 1. INSPECT REFRIGERANT VOLUME Observe the sight glass on the liquid tube. AC3 AC22F05 Test conditions: Running engine at 1,500 rpm Blower speed control switch: HI
Fluid Flow Instrumentation
Fluid Flow Instrumentation In the physical world, mechanical engineers are frequently required to monitor or control the flow of various fluids through pipes, ducts and assorted vessels. This fluid can
Emission Sampling Technologies. General Catalogue. Analitica Strumenti s.r.l.
2010 2011 Emission Sampling Technologies General Catalogue Analitica Strumenti s.r.l. Emission Sampling 4 Portable Heated Probe LD August 25, 2000 5 DiluGas Dynamic Analogue Diluter 5 IceFlow2 Peltier
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Elements Elements describe the essential outcomes.
AURETU005 Application Competency Field Unit Sector Elements Elements describe the essential outcomes. Retrofit and modify air conditioning and HVAC systems This unit describes the performance outcomes
INJECTION MOULD DESIGN: MARPLEX PVC RESINS
MACHINE RECCOMENDATIONS PVC requires reciprocating screw injection moulding machine with a plasticising screw to produce homogeneous melt. It is recommended that a shot weight of the part should take two
RITTER Multiple Sonic Nozzle Calibration System
RITTER Multiple Sonic Nozzle Calibration System »Wouldn t it be great to eliminate doubtful measurement results by using proven measurement technology? Providing the most precise results ensures and increases
Optimization Design for Sulfur Dioxide Flow Monitoring Apparatus in Thermal Power Plants Hao-wei Hu 1, a, Xue Yang 1, b and Xiao-wei Song 1, c
International Conference on Information Sciences, Machinery, Materials and Energy (ICISMME 2015) Optimization Design for Sulfur Dioxide Flow Monitoring Apparatus in Thermal Power Plants Hao-wei Hu 1, a,
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 HELPER AND INTERMEDIATE JOBS...
P. A. Hilton Ltd REFRIGERATION & AIR CONDITIONING VAPOUR COMPRESSION HEAT PUMPS VENTILATION VOCATIONAL
REFRIGERATION & AIR CONDITIONING Refrigeration and air conditioning is an aspect of modern life that is accepted almost without thought. Food storage, the long distance transport of foodstuffs, stockpiling
Test Code: 8297 / Version 1
Blueprint HVAC Maintenance Technology PA Test Code: 8297 / Version 1 Copyright 2014. All Rights Reserved. General Assessment Information HVAC Maintenance Technology PA Blueprint Contents General Assessment
Environmental Monitoring
Chapter 10 Environmental Monitoring By the end of this chapter, you will be able to: l List the types of environmental testing l Name three types of checks that are carried out to ensure the isolator is
Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations
Stephen Lowe ASHRAE Hampton Roads Chapter Past President AECOM Design Mechanical Engineering Discipline Manager, Virginia Beach Division Professional Engineer Commonwealth of Virginia, NCEES BSME University
Flow Measurement Options for Pipeline and Open Channel Flow
Flow Measurement Options for Pipeline and Open Channel Flow October 2013 Presented by Molly Skorpik - 2013 Montana Association of Dam and Canal Systems Conference Irrigation Training and Research Center
Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers
Filtering Samples to On-Line Process Analyzers Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers Filtering samples to on-line analyzers Use these guidelines to ensure
(S&G 5th ed. Expt 27, 6th, 7th & 8th eds. Expt 26)
Chem 367-2/ Physical Adsorption 63 PHYSICAL ADSORPTION (S&G 5th ed. Expt 27, 6th, 7th & 8th eds. Expt 26) The sample used in this experiment needs to be conditioned for at least two hours before the experiment;
TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL
Project No. 148 TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL Prepared for: Mr. Ted Tiberi Arid Technologies, Inc. 130 North LaGrange Rd. LaGrange, IL 60525 Prepared
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
CONTINUOUS MONITORING MANUAL. DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION 811 SW SIXTH AVENUE Portland, Oregon 97204
CONTINUOUS MONITORING MANUAL DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION 811 SW SIXTH AVENUE Portland, Oregon 97204 January 23, 1992 Table of Contents 1.0 INTRODUCTION... 1 2.0 DEFINITIONS...
Air Pollution Control Division. Technical Services Program
Page 1 of 10 Air Pollution Control Division Technical Services Program APPENDIX PM4 STANDARD OPERATING PROCEDURE FOR THE DETERMINATION OF PM 10 AND PM 2.5 IN AMBIENT AIR USING A GRIMM EDM 180 Page 2 of
Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations
Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations B e c k m a n C o u l t e r L i f e S c i e n c e s 2 5 0 S. K r a e m e r B o u l e
Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system
AURETU004 Application Competency Field Unit Sector Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system 2. Diagnose air conditioning and
CHAPTER 2 BIAS DUE TO PROBE LOCATION AND STRATIFICATION
CHAPTER 2 BIAS DUE TO PROBE LOCATION AND STRATIFICATION An Operator's Guide to Eliminating Bias in CEM Systems Chapter 2 Chapter 2 Highlights Probe Location and Stratification Problems Name Problem Corrective
CALCULATION OF FLOW VELOCITY AND VOLUME FLOW IN ISOKINETIC PIPES AND ATTACHED PIPES
CALCULATION OF FLOW VELOCITY AND VOLUME FLOW IN ISOKINETIC PIPES AND ATTACHED PIPES SGS BW TRAINING PAPERS : FLOW VELOCITIES 01 (SEE ALSO MSEXCEL FILE WITH ALGORITHMS) FRAME AND OBJECTIVES This paper describes
A P P L I C A T I O N S G U I D E. Duct Application Smoke Detectors
A P P L I C A T I O N S G U I D E Duct Application Smoke Detectors A P P L I C A T I O N S G U I D E Duct Application Smoke Detectors Contents Section 1 Introduction.......................................................................................2
World-Class Oil Sampling It is Possible
www.lubecontrol.com.au World-Class Oil Sampling It is Possible Lube Control Pty Ltd Providing lubrication solutions! Unit 5/53 Norfolk Rd, Marion, SA 5043 t: (08) 8298 5563 f: (08) 8298 6253 e: [email protected]
High School Graduation years 2013, 2014, 2015. Unit/Standard Number
1 Secondary Task List 100 INTRODUCTION TO HVAC 101 Identify HVAC systems. 102 Describe career opportunities in the HVAC profession. 103 Demonstrate awareness of the occupational requirements. 104 Explain
CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2
WASTE HEAT BOILERS CONTENTS 1 INTRODUCTION... 3 2 CONCEPTION OF WASTE HEAT BOILERS... 4 2.1 Complex Solution...4 2.2 Kind of Heat Exchange...5 2.3 Heat Recovery Units and Their Usage...5 2.4 Materials
STANDARD TESTING PROCEDURES (STP) FOR EVALUATION OF REMOVAL EFFICIENCY OF COOKING FUME CONTROL EQUIPMENT
STANDARD TESTING PROCEDURES (STP) FOR EVALUATION OF REMOVAL EFFICIENCY OF COOKING FUME CONTROL EQUIPMENT December 2004 (For Trial Use) TABLE OF CONTENTS Page 1. BACKGROUND 1 2. PURPOSE OF THE STP 1 3.
Energy Efficient Operations and Maintenance Strategies for Boilers
Energy Efficient Operations and Maintenance Strategies for Boilers Large, complex and widely used, industrial boilers are major consumers of fuel. Proper operations and maintenance (O&M) procedures must
R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler
[N.2.1.1] R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler (Environment-Friendly, High-Efficiency Boiler Group) Takashi Murakawa, Yasuhiro Kotani, Kazuhiro Kamijo, Koichi Tsujimoto, Hiroshi
S300 Series Dust Monitors
S301 DustGuard S303 Trend Monitor S304 Emission Monitor S305 Stack Monitor Intrinsically Safe (ATEX) Dust Monitors Split Architecture (Remote)Models Data Logging Software S300 Series Dust Monitors Dust
Waste Incineration Plants
Waste Incineration Plants Modern Technology for a better Environmental Welcome at Hafner! We Manufacture Systems for Energy Recovery from Wastes and Biomass as well as for Treatment of Hazardous Wastes.
Precision Humidity Measurement for Pharmaceutical Fluid Bed Tablet Coating
Precision Humidity Measurement for Pharmaceutical Fluid Bed Tablet Coating are several reasons why tablet cores are coated, including: Alpharma/Purepac is one of the largest global generic pharmaceutical
Flue gas measurement and control Partial-insertion pitot tubes in CEMS applications
Article AT/FLOW/002 EN Flue gas measurement and control Partial-insertion pitot tubes in CEMS applications Measurement made easy Specifying the most appropriate pitot flowmeter design in stack applications
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration
Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet
Perkins Statewide Articulation Agreement Documentation item: Secondary Task List Coversheet The Secondary School agrees to: A. Implement the approved PDE Program(s) of Study. B. Provide assessment of student
Technical Specification. Generating Set with Waukesha engine burning natural gas
Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the
MOLECULAR DRAG PUMPS MDP SERIES
MOLECULAR DRAG PUMPS MDP SERIES MOLECULAR DRAG PUMPS MDP SERIES If you need: to replace a rotary vane pump with a dry pump for an application at 10-3 a turbopump that can operate up to 10 a pump that can
Air Induction Systems
Air Induction Systems Air Supply Requirements of Diesels All internal combustion engines need an adequate supply of air that is clean, dry, filtered, fresh, and relatively cool. Adequate Supply Diesel
LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS WWW.LANCOM4.COM
PORTABLE FLUE GAS MONITORING WWW.LANCOM4.COM i CO low CO high O 2 NO NO2 NOx CO2 H2S SO2 CxHy QUALITY CUSTOMER SOLUTIONS AMETEK LAND HAS BEEN BUILDING PRECISION MEASURING EQUIPMENT SINCE 1947. WE ARE SPECIALISTS
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
Compressed Air Filters
Compressed Air Filters Superior Filtration for Increased Productivity What happens when you don t use an air filter? Kaeser Gives You the Air Quality You Require Ambient air contains contaminants that
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1 DANIEL MEASUREMENT AND CONTROL WHITE PAPER Application of the Orifice Meter for Accurate Gas Flow Measurement www.daniel.com Summary
HEPA FILTER DEFECTS ARE COMMON
HEPA FILTER DEFECTS ARE COMMON Kenneth F. Cherry 1 and Kenneth A. Smigielski 2 1 NCEC Inc. 2 First Solar LLC. ABSTRACT HEPA filters (High Efficiency Particulate Air) filters are claimed by vendors to have
Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested
DOP Solutions Technical Document: Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested Issue 1: Prepared by Neil Stephenson and Tim Triggs and edited by
TEXAS COMMISSION ON ENVIRONMENTAL QUALITY WORK ASSIGNMENT 5
TEXAS COMMISSION ON ENVIRONMENTAL QUALITY WORK ASSIGNMENT 5 DRAFT FLARE WASTE GAS FLOW RATE AND COMPOSITION MEASUREMENT METHODOLOGIES EVALUATION DOCUMENT Prepared By: Shell Global Solutions Shell Global
Techniques to Improve Measurement Accuracy in Power Plant Reported Emissions
Techniques to Improve Measurement Accuracy in Power Plant Reported Emissions Carlos E. Romero Nenad Sarunac Senior Research Engineer Principal Research Engineer Energy Research Center Energy Research Center
THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS
THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS INDOOR AIR QUALITY INSTRUMENTS UNDERSTANDING, ACCELERATED BREATHE A LITTLE EASIER WITH TSI Indoor air quality is a growing concern. With the increasing
Chokes. Types Reasons Basics of Operations Application
Chokes Types Reasons Basics of Operations Application Most Common Chokes Positive: Fixed orifice Disassemble to change bean Adjustable Provides variable orifice size through external adjustment Schematic
