Safety PLC for rolling stock Safety Controller Pluto Harsh Environment

Size: px
Start display at page:

Download "Safety PLC for rolling stock Safety Controller Pluto Harsh Environment"

Transcription

1 Safety PLC for rolling stock Safety Controller Pluto Harsh Environment

2 Safety PLC for rolling stock More reliability and safety The requirements for rail vehicles of today and tomorrow grow constantly. Faster and faster connections must be made while maintaining a high passenger comfort. This is why, in their daily use, trains are subjected to very high stress, related to Environmentironmental, electrical and mechanical factors. This calls for higher and higher regulatory standards for rail vehicles. helps satisfy the high expectations towards the safety of the vehicles delivers reliable components, solutions and systems for rolling stock, always complying with the current standard requirements. mong others, these include: Safety Controller Pluto D20 Harsh Environment Safety Controller Pluto D45 Harsh Environment Using equipment on trains what must be taken into account Rail vehicles must be specially equipped to be reliable within their respective areas and conditions of use. Examples of such areas and conditions include, among other things, the trains being primarily used in tunnels, or used at high speeds, or used as night trains with sleeping coaches. In providing trains with equipment, particular attention must be paid so the service life of the equipment is not shorter than the service interval of the rail vehicle. Furthermore, the safety of passengers must be guaranteed, so that in the event of an emergency no additional hazard is created by defective electric equipment an important aspect especially if escape routes are limited, e.g. in tunnel systems. is a leading global independent supplier of innovative and reliable technology for rolling stock, railway operators and railway infrastructure operators. Using its all-encompassing business experience in energy and automation technology, can offer reliable and cost-effective solutions for both these fields. 2 2TLC Safety PLC for rolling stock

3 General standards for railway use Fire protection and general electrotechnical requirements Continous operation in the most extreme of conditions lways on the move, despite heat, cold and humidity: the Environmentironmental conditions in which rail vehicles are used are generally far more extreme than in an industrial plant. Their electronic components must correspondingly be completely vibration-proof, resistant to cold, dry and humid heat, and the resulting condensed water. Furthermore, as well as their electromagnetic compatibility, these devices must meet particularly high fire safety requirements. In the event of a fire, danger to people comes not only from the flames, but also from the smoke and poisonous vapors. Complete reliability under extreme conditions as well as a high degree of safety must be guaranteed. Nothing can be left to chance. ll the components of a rail vehicle undergo numerous load tests before they are commissioned. Everything is tested and documented on the basis of safety standards and specifications. The standards for electronic equipment used in and on rail vehicles EN and IEC EN is the most important standard for electronic equipment used in and on rail vehicles. With the exception of local fire and smoke protection standards, this standard acts as an umbrella standard encompassing all the important electric and mechanical aspects. These include: the temperature according to EN the humidity according to EN the voltage supply according to EN the insulation coordination according to EN the electromagnetic compliance according to EN the shock and vibration resistance according to EN The fire and smoke protection standard EN EN provides a classification of risks according to the categories of operation and design of train. The design of trains include four very different types of trains, e.g. standard vehicles and special trains with sleeping coaches. These trains can be operated in different categories. ccording to EN , there are four such categories that depend on how many kilometers a route may lead through a tunnel or elevated section. combination of these two criteria is decisive in classifying the hazard levels. standard vehicle that drives through a tunnel for less than a kilometer is classified as HL1. elow you will find a table that shows the hazard level that depends on the combination of the operation categories and the design categories. Operation categories Design categories N D S Standard vehicle utomated train without emergency trained crew Double decked vehicle 1 Tunnel < 1 km HL1 HL1 HL1 HL2 2 Tunnel < 5 km HL2 HL2 HL2 HL2 Sleeping coach, 2-level or 1-level 3 Tunnel > 5 km HL2 HL2 HL2 HL3 Train without HL3 HL3 HL3 HL3 4 side evacuation The Harsh Environment versions of Pluto safety PLC can be used on all trains up to hazard level HL3. The main criteria specified by EN include, among others, the oxygen index, which must be above 32%. For the Harsh Environment Plutos, this condition is met. nother critical aspect is the production of smoke, as well as the transparency and toxicity of the smoke. In the event of a fire, an opacity value of 150 guarantees that the smoke does not completely block the sight and the passengers can still orient themselves in the train. Safety PLC for rolling stock 2TLC

4 Standards for railway use 4 2TLC Safety PLC for rolling stock

5 Safety PLC Pluto D20 / D45 Harsh Environment Standards for railway use Pluto Harsh Environment. complies with the following railway standards Climate resistance a) IEC , Test -25 C to -40 C b) IEC , Test +55 C to +70 C Relative air humidity IEC , Test Db % at +25 C to +55 C Environmentironment temperature Tests according to standard EN Shock and vibration resistance Tests according to standards EN 50155/IEC EN temperature class T2 ICE Cold ICE Dry heat ICE Damp heat cyclic a) IEC Random: 1.01 m/s²rms at Hz for 10 min b) IEC Random long-life: 5.72 m/s²rms at Hz for 5 h c) IEC Shock: 50 m/s² at 30 ms ±3 shocks Fire and smoke protection a) Hazard levels HL1 to HL3 according to EN b) Fire protection classes 1 4 according to DIN Tests according to standards EN and 2 / DIN 5510 Part 1 and 2 Standard references The certificate is based on the following standards: Functional safety EN 50155:2007 EN :2006 Railway pplications Electronic equipment used on rolling stock Railway applications - The specification and demonstration of Reliability, vailability, Maintainability and Safety (RMS) - Part 1: asic requirements and generic process EN 50129:2003 EN 50128:2001 and 2011 EN :2013 EN :2013 EN 61373:2010 EN :2007 EN :2007 EN Primary safety/emc EN :2001 EN :2006 EN :2006 EN :2006 EN :2006 EN :1999 EN :2003 EN 50153:2002 Railway applications - Communication, signalling and processing systems - Safety related electronic systems for signalling Railway applications - Communications, signalling and processing systems - Software for railway control and protection systems Railway applications - Fire protection on railway vehicles - Part 1: General requirements Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behavior of materials and components Railway applications rolling stock equipment, shock and vibration tests asic Environmentironmental testing procedures - Part 2: Tests - Test : Cold Environmentironmental testing - Part 2-2: Tests - Test : Dry heat Environmentironmental testing - Part 2: Tests - Test Db and guidance: Damp heat, cyclic ( hour cycle) Railway applications - Insulation coordination - Part 1: asic requirements - Clearances and creepage distances for all electrical and electronic equipment Railway applications - Electromagnetic compatibility - Part 1: General Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus Railway applications - Electromagnetic compatibility - Part 3-1: Rolling stock - Train and complete vehicle Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - pparatus Railway applications - Environmentironmental conditions for equipment - Part 1: Rolling stock and on-board equipment Railway applications - Environmentironmental conditions for equipment - Part 3: Equipment for signalling and telecommunications Railway applications - Rolling stock - Protective provisions relating to electrical hazards Safety PLC for rolling stock 2TLC

6 pplication examples for the Pluto safety PLC Locomotive Pluto D20 Harsh Environment or Pluto D45 Harsh Environment Supervising brake systems Switch-off functions for brake systems Speed monitoring and control with rotary encoders (acceleration and braking functions) Measurement and monitoring functions Monitoring of protection of high voltage area Monitoring of pantograph position Emergency power supply monitoring 2 / 3 Passenger car 4 Dining car Pluto D20 Harsh Environment or Pluto D45 Harsh Environment Door monitoring using Eden Door control, e.g. opening/closing and selection for opening doors on the right or left side of the vehicle Overheating protection Supervising brake systems Switch-off functions for brake systems Measurement and monitoring functions 6 2TLC Safety PLC for rolling stock

7 Pluto safety PLC for a comprehensive concept D20 / D45 Harsh Environment Pluto D45 Safety PLC, Harsh Environment Pluto D20 Safety PLC, Harsh Environment Pluto is a safety PLC concept with the ll-master key feature, which simplifies safety system design and complies with the highest safety level, PL e, according to EN ISO and SIL 3 according to EN 62061, IEC/EN It also complies with all the relevant parts of EN Pluto is an ll-master system for dynamic and static safety circuits, in which the inputs and other data are distributed via the same bus. One input can be used to connect several safety sensors, while maintaining the highest safety level. Pluto offers inputs for every safety product on the market. The function of the inputs is defined via the Pluto Manager software that is supplied with the equipment. part from failsafe inputs (I), Pluto offers several failsafe relay and transistor outputs (Q). On every Pluto, even more failsafe inputs, non-failsafe outputs or simultaneous input/outputs (IQ) be set up. The features are provided in a simple way in Pluto Manager. Up to 32 Plutos can be connected to the same Pluto bus, making Pluto able to manage both small and large safety systems. s Pluto is an ll-master system, each Pluto unit can control its own outputs locally and read the inputs of other Pluto units as easily as its own. Gateways on the Pluto bus allow for data exchange with other systems. Pluto D20 and D45 with analog inputs Pluto D20 is equipped with 4, and Pluto D45 with 8 safe analog inputs (4 20 m/0 10 V). These can be configured as either ordinary failsafe inputs or as analog inputs (0 10 V or 4 20 m). Counter inputs Pluto D45 In Pluto D45, four of its analog inputs can be configuredas counter inputs (pulse counting) for frequencies of up to 14,000 Hz. The counter inputs I0 I3 can be used in two ways (counting forwards or forwards/backwards). IDFIX-PROG With IDFIX-PROG 2k5 or 10k it is possible to save entire projects. IDFIX-PROG is an additional component for the Pluto safety PLC used primarily for models without safety bus. It makes sure that the program can be easily recovered, in case the Pluto should need to be replaced. This means that no laptop is required when replacing units on the rail vehicle, which can lower downtimes to a minimum. IDFIX-PROG 10k (2TL020070R2600) Safety PLC for rolling stock 2TLC

8 Safety PLC Pluto D20 / D45 Harsh Environment Technical data Ordering data Pluto D20 Safety PLC, Harsh Environment Pluto D45 Safety PLC, Harsh Environment Power supply Operating voltage 2TL020070R6401 2TL020070R V DC Voltage tolerance -30% +25%* Max. disconnection Recommended external fuse Total power consumption Own power consumption 20 ms m Electrical insulation Category II according to IEC Failsafe inputs (incl. counter inputs) I0, I1, I2, V (for PNP sensors) IQ10, IQ11,.. Logical 1 Logical 0 Current at 24 V Max. overvoltage nalogue inputs (I0-I7) Range Contacts Resolution Precision + 24 V (for PNP sensors) configurable also as non-failsafe outputs > 12 V < 8 V 5.1 m 27 V continuous 0 10 V / m I0, I1, I2, I3, I4, I5, I6, I7 12 bit 0 10 V: ±0.4 % of the entire range 4 20 m: ±0.2 % of the entire range Counter inputs (Pluto D45) Maximum frequency Failsafe outputs 14 khz at 50% load Q2, Q3: Transistor, -24 V DC, 800 m Output voltage tolerance <10 C: 250 m Supply voltage 1.5 V at 800 m Q0, Q1, Q4, Q5: Relay C-12: 250 V / 1.5 Non-failsafe outputs IQ10, IQ11,.. Max. current/output: Max. total load: IQ : IQ20..27: Indicators Input/Output LEDs C-15: 250 V / 1.5 DC-12: 50 V / 1.5 DC-13: 24 V / 1.5 Transistor +24 V (PNP open collector) configurable also as non-failsafe inputs 800 m 2 2 Processor-controlled * The increased tolerance for the Pluto D45 Harsh Environment version is intermittent and must not be used for long periods. t voltages under 18 V and over 30 V, the following warning messages are shown on the display (Er 15 and Er 16). These messages have no influence on the operation and can be suppressed. General Casing 90 x 84 x 120 mm (W x H x D) Installation DIN-rail Response times for the dynamic signal or the static (+24 V) signal: Relay outputs Q0, Q1, Q4, Q5: <20.5 ms + program execution time Transistor outputs Q2, Q3: <16.5 ms + program execution time Transistor outputs Q10...Q17: <16.5 ms + program execution time Response times for the dynamic signals and C: Relay outputs Q0, Q1, Q4, Q5: <23 ms + program execution time Transistor outputs Q2, Q3: <19 ms + program execution time Transistor outputs Q10...Q17: <19 ms + program execution time Software setting NoFilt Response times: 5 ms (5 ms less) Program execution time approx. 10 µs/command dditional response times via the bus: Normal conditions 10 ms t fault condition ms Response time extension for Q2 and Q3 at fault condition <10 ms Recognition times Shortest recognizable impulse 10 ms mbient temperature -25 to +55 C Transportation and storage -25 to +55 C temperature Environmentironment temperature EN temperature class T2 Humidity: IEC , Test Db 90 % at 40 C (e.g % at +25 C to +55 C) EN % at 40 C (e.g. 90 % at 20 C) Enclosure classification, IEC : Enclosure IP 40 Connection terminals IP 20 Fire and smoke protection: EN Hazard levels HL1 to HL3 DIN Fire protection classes 1 2 Functional safety data SIL according to SIL 3 EN 62061/IEC PL according to EN ISO PL e Category according to 4 EN ISO DC avg according to EN ISO High CCF according to EN ISO Requirements are met HFT (Hardware fault tolerance) 1 SFF (Safe failure fraction) >99% for single-channel systems >90% for two-channel systems 8 2TLC Safety PLC for rolling stock

9 Safety PLC Pluto D20 / D45 Harsh Environment Technical data Transistor outputs* PFD V (for mission time = 20 years) 1.1x10-4 PFH D according to EN 62061/IEC x10-9 MTTF d according to EN ISO Relay outputs* PFD V (for mission time = 20 years) 1.5x10-4 PFH D according to EN 62061/IEC x10-9 MTTF d according to EN ISO High/1500 years High/1100 years nalog inputs* Pluto D45 2 sensors 1 sensor SIL according to EN 62061/IEC up to SIL 3 up to SIL 2 PL according to EN ISO up to PL e up to PL d DC avg according to EN ISO up to High up to Medium PFD V (for mission time = 20 years) 1.5x x10-3 PFH D according to EN 62061/IEC x x10-9 MTTF d according to EN ISO High/1100 years High/400 years Counter inputs* Pluto D45 2 sensors 1 sensor SIL according to EN 62061/IEC up to SIL 3 up to SIL 1 PL according to EN ISO up to PL e up to PL c DC avg according to EN ISO up to High up to High PFD V (for mission time = 20 years) 1.5x x10-4 PFH D according to EN 62061/IEC x x10-9 MTTF d according to EN ISO High/1100 years High/1100 years Note: PFD V = average probability of failure on demand of the safety function PFH D = average probability of a dangerous failure per hour MTTF d = average time until a dangerous failure/channel PL = Performance Level (according to the definition specified in EN ISO ) SIL = Safety Integrity Level (according to the definition specified in EN 62061/IEC 61508) * from the input to the output (incl. the S-i and CN us) Outline drawings Safety PLC for rolling stock 2TLC

10 Safety PLC Pluto D20 Harsh Environment Technical data Pluto bus 0-10V/4-20m Inputs, individual failsafe Transistor output, individual failsafe CH IQ10 CL IQ11 I0 I1 Pluto D20 Harsh Env DI I IQ12 DI I I2 DI I IQ13 I3 DI I I4 IQ14 I5 IQ15 I6 I7 DI DI DI DI I 0-24V IQ16 IQ17 Q0 Q1 Q2 Q3 ID 0V +24V Failsafe inputs / Indication outputs (not failsafe) / Dynamic outputs Relay output, individual failsafe Identifier input Power Overview for inputs/outputs in Pluto D20 Harsh Environment Terminals at Pluto Input/Output name in the software I/O type I4 I7 I_.4 I_.7 Safe digital input/safe analog input 4 20 m/0 10 V Global Q0 Q_.0 Safe output (relay) Global Q1 Q_.1 Safe output (relay) Global Q2 Q_.2 Safe output (transistor) Global Q3 Q_.3 Safe output (transistor) Global IQ10 IQ17 I_.10 I_.17 Safe digital input Global Where _ is the Pluto module number. Q_.10 Q_.17 Non-safe output Local Local/global Safety PLC Pluto D20 Harsh Environment The Pluto safety PLC D20 has 16 failsafe inputs and 4 independent failsafe outputs (2x relay and 2x transistor). Out of the 16 failsafe inputs, any 4 can be configured as analog inputs with a high 10 bit resolution, and 8 can be configured as non-safe outputs. The analog inputs are analyzed with safe function blocks with scalable outputs. 10 2TLC Safety PLC for rolling stock

11 Safety PLC Pluto D45 Harsh Environment Technical data Digital inputs, individual failsafe nalogue inputs 0-10V/4-20m Fast counter Inputs, individual failsafe Inputs, individual failsafe +24V 0V 0V Power supply ID Identifier IDFIX CH CL I0 CS (Shield) I1 I2 Pluto bus I3 I4 I5 I6 I7 I30 Pluto D45 Harsh Env I31 I32 I33 I34 I35 I36 I37 I40 I41 I42 I43 I44 I45 I46 Safety outputs Q0 Q1 Q4 Q5 I47 0L 1L 4L IQ10 IQ11 IQ12 IQ13 IQ14 IQ15 IQ16 IQ17 IQ20 IQ21 IQ22 IQ23 IQ24 IQ25 IQ26 Q2 Q3 Failsafe inputs / Outputs (not failsafe) / Dynamic outputs Overview for inputs/outputs in Pluto D45 Harsh Environment Terminals at Pluto Input/Output name in the software I/O type I0 I3 I_.0 I_.3 Safe digital input/safe analog input 4 20 m/0 10 V/counter input Global I4 I7 I_.4 I_.7 Safe digital input/safe analog input 4 20 m/0 10 V Global I30...I37 I_.30 I_.37 Safe digital input Local I40...I47 I_.40 I_.47 Safe digital input Local Q0 Q_.0 Safe output (relay) Global Q1 Q_.1 Safe output (relay) Global Q2 Q_.2 Safe output (transistor) Global Q3 Q_.3 Safe output (transistor) Global Q4 Q_.4 Safe output (relay) Local Q5 Q_.5 Safe output (relay) Local IQ10 IQ17 I_.10 I_.17 Safe digital input Global Q_.10 Q_.17 Non-safe output Local IQ20 IQ26 I_.20 I_.26 Safe digital input Local Where _ is the Pluto module number. Q_.20 Q_.26 Non-safe output Local Local/global Pluto D45: the all-in-one solution that makes rolling stock safe The new Pluto safety PLC D45 has 39 failsafe inputs and 6 independent failsafe outputs (4x relay and 2x transistor). Out of the 39 inputs, any 8 can be configured as analog inputs with a high 12 bit resolution, and 15 can be configured as non-safe outputs. Furthermore, the 4 inputs can be configured as fast and failsafe counter inputs for monitoring frequencies of up to 14 khz. Using the fast counter inputs, demanding applications via incremental encoders, inductive sensors and photo cells can be implemented. Safety PLC for rolling stock 2TLC

12 Contacts Jokab Safety Varlabergsvägen 11 SE Kungsbacka Tel. +46 (0) Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. ny reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of. 2TLC Copyright 2016 ll rights reserved

Safety Manual BT50(T) Safety relay / Expansion relay

Safety Manual BT50(T) Safety relay / Expansion relay Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

SAFETY MANUAL SIL RELAY MODULE

SAFETY MANUAL SIL RELAY MODULE PROCESS AUTOMATION SAFETY MANUAL SIL RELAY MODULE KFD0-RSH-1.4S.PS2 ISO9001 3 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate

More information

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,

More information

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver

More information

SAFETY MANUAL SIL Switch Amplifier

SAFETY MANUAL SIL Switch Amplifier PROCESS AUTOMATION SAFETY MANUAL SIL Switch Amplifier KCD2-SR-(Ex)*(.LB)(.SP), HiC282* ISO9001 2 With regard to the supply of products, the current issue of the following document is applicable: The General

More information

Original instructions Tina 3A/Aps Adaptor unit

Original instructions Tina 3A/Aps Adaptor unit Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

MNS is Switchgear System Technical Overview

MNS is Switchgear System Technical Overview Switchgear System Technical Overview Innovative Design ABB s innovative MNS is concept combines the long term experience, energy efficiency, grid reliability and industrial productivity of the well-known

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

ZS25 Screw Clamp Terminal Blocks Feed-through

ZS25 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD

More information

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

FAdC i FRAUSCHER Advanced Counter i

FAdC i FRAUSCHER Advanced Counter i FAdC i FRAUSCHER Advanced Counter i EN FAdC i FRAUSCHER Advanced Counter i Track vacancy detection for special requirements The FAdCi is a particularly cost-effective version of the latest generation of

More information

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP Programmable Safety controllers g9sp G9SP compact Stand-Alone Programmable controller Stand-alone safety controller for small and mid-sized machinery Easy programming for complex safety control Three types

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Tina 2A/B Adaptor unit

Tina 2A/B Adaptor unit Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Plant-STOP 9475 Company: R. STAHL Schaltgeräte GmbH Waldenburg Germany Contract No.: STAHL 13/04-027 Report No.: STAHL 13/04-027 R024 Version V1,

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Smart DeviceNet Remote I/O Terminals

Smart DeviceNet Remote I/O Terminals Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems

More information

NX safety stand-alone

NX safety stand-alone NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Machineontwerp volgens IEC 62061

Machineontwerp volgens IEC 62061 Machineontwerp volgens IEC 62061 Insert Photo Here Safety solution Architect Safety Local Business Leader Benelux. Stephen Podevyn Safety Solution Seminar Agenda deel 1 1. Richtlijnen en normen 2. Safety

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053. PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection

More information

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Available with a safe bus system or/and two counter inputs

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

SINEAX U553 Transducer for AC Voltage

SINEAX U553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

Plug-in relays Mini ISO relays

Plug-in relays Mini ISO relays Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features Limiting continuous current 70 A Dimensional characteristics and the functional allocation of

More information

MTCS Modular Train Control System

MTCS Modular Train Control System MTCS Modular Train Control System SIL 4 Railway Computer for Rolling Stock and Wayside Applications In Accordance with: EN 50155 EN 50121-4 EN 50129 EN 50126 EN 50128 The MTCS Approach... 4» MTCS Modular

More information

PCB Relays Twin Relays

PCB Relays Twin Relays Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features - Two separate systems - Lamp applications - Extremely space saving double relay Typical applications

More information

C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19

C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19 C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment

More information

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0 Data sheet GIOD.1 Input/output module with CAN bus ERP no.: 5204183 www.guentner.de Page 2 / 10 Contents 1 GIOD.1... 3 1.1 Functional description...3 1.2 Connections... 5 1.3 Electrical properties of...

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Arc Terminator Active Arc-Resistant Switchgear

Arc Terminator Active Arc-Resistant Switchgear Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers

More information

Unidirectional Transmitter/ Receiver Units Introduction

Unidirectional Transmitter/ Receiver Units Introduction Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Catalog Edition 2014. DIN-Rail components for rolling stock applications

Catalog Edition 2014. DIN-Rail components for rolling stock applications Catalog Edition 014 DIN-Rail components for rolling stock applications 1 3 4 5 6 7 8 9 10 11 1 13 14 15 16 17 18 CDC00053D004 DIN Rail components for rolling stock applications DIN-Rail components for

More information

Foxboro Evo Process Automation System

Foxboro Evo Process Automation System Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

SAFETY MANUAL SIL SMART Transmitter Power Supply

SAFETY MANUAL SIL SMART Transmitter Power Supply PROCESS AUTOMATION SAFETY MANUAL SIL SMART Transmitter Power Supply KFD2-STC4-(Ex)*, KFD2-STV4-(Ex)*, KFD2-CR4-(Ex)* ISO9001 2 3 With regard to the supply of products, the current issue of the following

More information

CQM1-SF200/CS1W-SF200

CQM1-SF200/CS1W-SF200 Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Contact expansion modules

Contact expansion modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts

More information

SYSTEM DESCRIPTION Termination Boards

SYSTEM DESCRIPTION Termination Boards PROCESS AUTOMATION SYSTEM DESCRIPTION Termination Boards Non-IS Termination Boards for Yokogawa CENTUM C3 and ProSafe RS ISO9001 With regard to the supply of products, the current issue of the following

More information

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797

More information

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

AMIS. Automated Metering and Information System. Integration of meters from other manufacturers

AMIS. Automated Metering and Information System. Integration of meters from other manufacturers AMIS Automated Metering and Information System TD-3530/TACU30 Third-Party Device Gateway Integration of meters from other manufacturers Connection and integration of max. 3 meters from third party manufactureres

More information

SIMATIC. S7-300 and M7-300 Programmable Controllers Module Specifications. Preface, Contents. General Technical Specifications. Power Supply Modules

SIMATIC. S7-300 and M7-300 Programmable Controllers Module Specifications. Preface, Contents. General Technical Specifications. Power Supply Modules SIMATIC S7-300 and M7-300 Programmable Controllers Module Specifications Reference manual This manual is part of the following documentation packages with order nos: S7 300 Programmable Controller: 6ES7

More information