RIVISTA DI NEURORADIOLOGIA

Size: px
Start display at page:

Download "RIVISTA DI NEURORADIOLOGIA"

Transcription

1 RIVISTA DI NEURORADIOLOGIA ORGANO UFFICIALE DELL ASSOCIAZIONE ITALIANA DI NEURORADIOLOGIA OFFICIAL JOURNAL OF THE TURKISH SOCIETY OF NEURORADIOLOGY Index Introduction 743 T. Scarabino Legislation Governing the Authorization, 745 Installation and Use of 3.0 TMR Imaging Systems A. Maiorana, V. d Alesio, T. Scarabino High Field Strength Magnetic Resonance 748 and Safety. Part I. Installation A. Maiorana, V. d Alesio, M. Tosetti, T. Scarabino High Field Strength Magnetic Resonance 752 and Safety. Part II. Use T. Scarabino, F. Nemore, G.M. Giannatempo, A. Maiorana Semeiological Features of 3.0 T 755 MR Imaging: What Changes at High Magnetic Field T. Scarabino, F. Nemore, G.M. Giannatempo, T. Popolizio, M. Tosetti, F. Esposito, F. Di Salle, U. Salvolini 3.0 T MR Imaging 765 T. Scarabino, F. Nemore, G.M. Giannatempo, T. Popolizio, A. Stranieri, U. Salvolini 3.0 T MR Angiography 777 T. Scarabino, F. Nemore, G.M. Giannatempo, T. Popolizio, A. Stranieri, A. Carriero, U. Salvolini 3.0 T Proton MR Spectroscopy 784 T. Scarabino, F. Nemore, G.M. Giannatempo, A. Bertolino, M. Tosetti, A. Di Costanzo, G. Polonara, U. Salvolini 3.0 T Diffusion MR Imaging 795 T. Scarabino, F. Nemore, F. Esposito, F. Di Salle, S. Pollice, A. Carriero, R. Agati, U. Salvolini 3.0 T Perfusion MR Imaging 807 T. Scarabino, G.M. Giannatempo, S. Pollice, A. Carriero, A. Di Costanzo, G. Tedeschi, G. Polonara, U. Salvolini Functional MRI at High Field Strength 813 F. Di Salle, T. Scarabino, F. Esposito, A. Aragri, O. Santopaolo, A. Elefante, M. Cirillo, S. Cirillo, R. Elefante 3 T MR Multiparametric Assessment 822 of Cerebral Gliomas A. Di Costanzo, T. Scarabino, F. Nemore, G.M. Giannatempo, F. Trojsi, S. Pollice, A. Carriero, G. Tedeschi, U. Salvolini Schizophrenia and 3.0 T fmri 827 V. Latorre, V. Rubino, T. Scarabino A. Bertolino 3 T MR Angiography in Spinal 834 Dural Fistula. A Pictorial Presentation R. Agati, A.F. Marliani, D. Cevolani, C. Carollo, M. Leonardi Pre-Surgical Use of Functional Paradigms 836 in Brain fmri Mapping: Our Initial 3 T Experience D. Cevolani, R. Agati, L. Albini Riccioli, S. Battaglia, H. Hacker, M. Leonardi Potential Impact of Advanced 3 Tesla 849 Diagnostics in the Management of Patients with Brain Tumours M. Leonardi, R. Agati, D. Cevolani, A. Bacci, R. Ricci, L. Albini Riccioli, S. Battaglia, M. Maffei, L. Simonetti, M. Spagnoli, H. Hacker 1 HMRS 3 T In Vivo and In Vitro and 882 Anatomopathological Correlations in Extracerebral Tumours. A Report of Two Cases R. Ricci, A. Bacci, V. Tugnoli, M.R. Tosi, R. Agati, A.F. Marliani, M. Messia, R. Ferracini, M. Leonardi

2 3 T MR Assessment of Pituitary 890 Microadenomas. A Report of Six Cases R. Agati, M. Maffei, A. Bacci, D. Cevolani, S. Battaglia, M. Leonardi Information & Congresses 896, 897, 898 Instructions to Authors 904 Cover: P. Ghedin, Selfportrait; Bologna 2004

3 Fotografia realizzata in collaborazione con Edward Hospital & Health Services, Naperville, Illinois. Vittorie di ogni giorno Oggi ci siamo ricordati perché abbiamo scelto questa professione. Da quando la sanità ha iniziato funzionare secondo le regole di ogni altra attività economica, qualche volta ci capita di dimenticare i veri motivi per cui abbiamo scelto la nostra professione. I presupposti che in passato ci guidavano nella gestione di un sistema ospedaliero non sono più attuali. Il nostro desiderio di offrire ai pazienti un assistenza di prim ordine si scontrava sempre più con la realtà finanziaria. E buona parte del cosiddetto stato dell arte della tecnologia sembrava complicare un contesto di lavoro già frenetico. Così abbiamo dato una svolta alla nostra vita. Abbiamo scoperto una tecnologia più avanzata che la semplifica. Abbiamo trovato il modo di raggiungere l eccellenza clinica facendo quadrare i bilanci. Di fare di più e diminuire lo stress. Ora possiamo affidarci a un servizio di assistenza come i nostri pazienti si affidano a noi. È per questo che oggi abbiamo avuto più tempo da dedicare ai nostri pazienti. Perché usiamo un sistema progettato per noi. Semplice questione di logica. Per dare una svolta alle vostre scelte, contattate Philips.

4

5 320 di accessibilità. L innovazione a 0,4 Tesla. Una soluzione per la RM ad Alto Campo. ESAOTE s.p.a Genova - Via Siffredi, 58 Tel. 010/ Fax 010/ Firenze - Via di Caciolle, 15

6

7 Rivista di Neuroradiologia 17: , 2004 www. centauro. it Introduction T. SCARABINO Neuroradiologia, Dipartimento di Scienze Radiologiche, Istituto Scientifico Casa Sollievo della Sofferenza ; San Giovanni Rotondo, Foggia Since the advent of magnetic resonance (MR) imaging, systems with a magnetic field intensity of 1.5 tesla (T) have been deemed the gold standard to cover different clinical applications in all body districts. Ongoing advances in hardware and software have made these MR systems increasingly compact, powerful and versatile, leading to the development of higher magnetic field strength MR systems (3.0 T) for use in clinical practice and for research purposes. As usually occurs with a new technology, MR 3.0 T imaging units will probably follow the same development trends in the years to come. These new systems are currently in routine use mainly in the United States, but despite their high cost they are increasingly being adopted for research in much broader fields than those of conventional MR systems, and also in daily clinical practice for new, more sophisticated applications bringing major practical benefits. Results to date have been encouraging with respect to previous experience with lower field strength MR systems and show that the many advantages of 3.0 T imaging (high signal, high resolution, high sensitivity, shorter imaging times, additional more advanced study procedures and enhanced diagnostic capacity) will become the future standard for morphofunctional study of the brain. When future technological advances have resolved some of the shortcomings of new 3.0 T systems (inhomogenity of the field, artifacts caused by susceptibility and chemical shift, elevated SAR, high costs), the current MR units will gradually be replaced by higher field strength MR imaging. The 3.0 T MR systems of the future will offer morphological investigation with high spatial, temporal and contrast resolution (essential for diagnosis) and also yield physiological, metabolic and functional information enhancing the diagnostic power of routine MR imaging in terms of sensitivity and specificity both in clinical practice and for applied research purposes. A 3.0 T system can quickly build up a database of information useful in different diseases and including structural and functional data. Just one MR investigation will therefore comprise basic structural imaging and also diffusion and perfusion studies, MR spectroscopy, visual fmri or even imaging of other nuclei. However, such systems should not be considered the optimum for myriad clinical applications and all body districts. It is important to be aware of the technical characteristics, image features and applications of each MR system of different field strength so as to use the various systems in the best possible way depending on the investigation required. For this reason, the new MR systems are best confined at present to tertiary care centres or institutions already using other MR systems in routine clinical practice and research. A multidisciplinary task force is essential to exploit the potential of these new systems to 743

8 Introduction T. Scarabino the full and I take this opportunity to thank the team of doctors and technicians of the Neuroradiology and Health Physics Department at our institution (in particular my neuroradiologist colleagues F. Nemore, G.M. Giannatempo and T. Popolizio, and physicists A. Maiorana and V. d Alesio) but also other neuroimaging experts working elsewhere including neuroradiologists U. Salvolini (University of Ancona), F. Di Salle (University of Naples); psychiatrists M. Nardini, A. Bertolino, G. Blasi, V. La Torre, V. Rubino and F. Sambataro (University of Bari); child neuropsychiatrists V. Leuzzi ( La Sapienza University, Rome), F. Carnevale (University of Bari) and M. Burroni (Fano Hospital); neurologists G. Tedeschi and A. Di Costanzo (University of Naples); physicist M. Tosetti ( Stella Maris Hospital, Pisa) and bioengineer F. Esposito (University of Naples). Special thanks are due to the entire staff of General Electric, in particular P. Ghedin (Advanced Clinical Applications), for their untiring professional support. This special issue of the Rivista di Neuroradiologia devoted to 3.0 T MR systems includes papers on: 1. Legislation in force governing authorization, installation and use. 2. Safety problems related to installation (with reference to static magnetic field, variable magnetic fields, cryogenic gases, acoustic noise and quality control). 3. Safety problems relating to use (with reference to precautions adopted by medical and technical personnel in relation to MR-compatibility and the standard of patient comfort). 4. The semeiological features of 3.0 T images including reference to advantages and drawbacks with respect to lower field strength MR systems. 5. The main clinical applications in neuroradiology. 6. Future trends. Dr T. Scarabino Neuroradiologia Dipartimento di Scienze Radiologiche Istituto Scientifico Casa Sollievo della Sofferenza Viale Cappuccini, San Giovanni Rotondo - FG Tel t.scarabino@operapadrepio.it 744

9 Rivista di Neuroradiologia 17: , 2004 www. centauro. it Legislation Governing the Authorization, Installation and Use of 3.0 T MR Imaging Systems A. MAIORANA, V. d ALESIO, T. SCARABINO* Fisica Sanitaria, *Neuroradiologia, Dipartimento di Scienze Radiologiche, Istituto Scientifico Casa Sollievo della Sofferenza ; San Giovanni Rotondo, Foggia Key words: 3.0 T MRI, legislation, high field MRI INTRODUCTION With the advent and development of high-field strength magnetic resonance (MR) imaging systems, legislation governing the authorization and use of these systems has undergone major amendments in recent years, especially in the USA where the new imaging units are more widespread. Ongoing advances and the future development of newer more sophisticated MR systems will entail further amendments to legislation in the wake of advances in strong magnetic field strength now known as a moving target. This is borne out by the increasing use in the USA of 3.0 T MR systems instead of the 1.5 T units long deemed the standard for neuroradiological imaging. In contrast, European, in particular Italian, legislation dates back to As use of the new MR systems increases nationwide, Italian regulations are likely to be brought into line with American legislation in the near future. Legislation in the USA In 1997 the United States Department of Health and Human Services Food and Drug Administration, Center for Devices and Radiological Health (U.S. F.D.A.), the classification of imaging carrying a significant risk and hence subjected to special authorization procedures was confined to MR systems in which the main static magnetic field exceeds 4.0 Tesla with a SAR of more than 4 watts per kilogram (W/kg) to the whole body for 15 minutes, 3 W/kg to the brain for ten minutes, 8 W/kg to each gram of head and torso tissue for 15 minutes, or 15 W/kg to each gram of tissue in the extremities for 15 minutes 1. A further condition is that the field gradient is sufficient to produce discomfort or pain and that the acoustic noise reaches a sound pressure level of 99 db or a peak value exceeding 140 db. According to this classification, a 3.0 T MR imaging system respecting the SAR, gradient and noise limits is broadly similar to a 1.5 T unit and does not entail significant risks and hence further restrictions with respect to conventional MR devices. In July 2003, the F.D.A. laid down new upper limits of static magnetic field for the sale of MR systems without special limits on MR diagnostic systems, replacing the 1997 guidelines. The new limits are 8.0 T for adults and 4.0 T for newborns under one month of age 2. Legislation in Italy In Italy the technical reference law is the CEI EN /A11 of , superseded in 2002 by IEC Ed Current national legislation, law 542 dated 8th August 1994, bans systems with a field strength equal to or in excess of 2.0 T from clinical practice and limits their use to documented research projects. Attachments to ministerial decrees dated 2nd August 1991 and 3rd August 1993, currently in force, list the limitations on SAR and gradients (tables I, II, III, IV) and basically refer to the indications of the Italian Electrotechnical Committee (CEI EN ). Article 6 of law 542 classified systems with a 745

10 Legislation Governing the Authorization, Installation and Use of 3.0 T MR Imaging Systems A. Maiorana Table I Limits of SAR to the whole body 1st level (normal working) Table II Limits of SAR to the whole body 2nd level (controlled working) Duration of exposure SAR Duration of exposure SAR t < 15 min < 2 W/kg t < 15 min < 4 W/kg 15 < t < 30 min < [30/t(min)] W/kg 15 < t < 30 min < [60/t(min)] W/kg t > 30 min < 1 W/kg t > 30 min < 2 W/kg Table III Limits of SAR per body district Duration of exposure SAR HEAD TORSO LIMBS t< 15 min < 4 W/kg < 8 W/kg < 12 W/kg 15 < t < 30 min < [60/t(min)] W/kg < [120/t(min)] W/kg < [180/t(min)] W/kg t > 30 min < 2 W/kg < 4 W/kg < 6 W/kg Table IV Value and duration of gradients Duration of variations Peak value t > 120 µs < 20 T/s 12 µs < t < 120 µs < [2400/t(µs)] T/s t < 12 µs < 200 T/s Table V Limits for static magnetic field Type of exposure Weighted average over time to whole body Limit to whole body Extremities Peak value 200 mt 2 T 5 T static magnetic field exceeding 2 T as group B, i.e. systems subject to ministerial authorization. The installation and use of these systems is confined to large tertiary level research centres (art. 4 par. 2). These MR systems must be part of a scientific or clinical research project requiring the use of ultrahigh strength magnetic fields. The same article also states that systems with a field strength exceeding 4.0 T can only be authorized for specific, documented needs of scientific or clinical research confined to the limbs. Authorization for the use of group B systems issued by the Italian Ministry of health is currently dependent on the prior technical evaluation of the Institute for Accident Prevention and Safety at Work (ISPESL), the Higher Institute of Health (ISS) and the Higher Council of Health (CSS). In relation to the protection of technical personnel from adverse effects, the International Commission for Non Ionizing Radiation Protection (ICNIRP) fixed the limits for static magnetic fields in (table V). It is interesting to compare these limits with those currently in force in Italy as specified in the attachments to the ministerial decree dated 2 nd August 1991 (table VI). Whereas the limits largely overlap (apart from those for limbs and extremities), the average values and time intervals on which such limits must be applied vary widely. Table VI Limits for static magnetic field (law 2 nd August 1991) Type of exposure To whole body (1 hour a day) To whole body (15 minutes a day) To limbs (1 hour a day) To limbs (1 minute a day) Peak value 200 mt 2 T 2 T 4 T 746

11 www. centauro. it Rivista di Neuroradiologia 17: , 2004 References 1 Food and Drug Administration Center for Devices and Radiological Health. Guidance for Magnetic Resonance Diagnostic Devices. Criteria for Significant Risk Investigation Food and Drug Administration Center for Devices and Radiological Health, Criteria for Significant Risk Investigations of Magnetic Resonance Diagnostic Devices Comitato Elettrotecnico Italiano, Apparecchi Elettromedicali Parte 2: Prescrizioni particolari d sicurezza relative agli apparecchi a risonanza magnetica per diagnostica medica. CEI EN /A International Electrotechnical Commission. Medical electrical equipment. Part 2-33: Particular requirements for the safety of magnetic resonance equipment for medical diagnosis. IEC Ed International Commission for non Ionizing Radiation Protection, Guidelines on limits of exposure to static magnetic fields Health Physics Society 66: Dr T. Scarabino Neuroradiologia Dipartimento di Scienze Radiologiche Istituto Scientifico Casa Sollievo della Sofferenza Viale Cappuccini, San Giovanni Rotondo - FG Tel

12 Rivista di Neuroradiologia 17: , 2004 www. centauro. it High Field Strength Magnetic Resonance and Safety Part I. Installation A. MAIORANA, V. d ALESIO, M. TOSETTI*, T. SCARABINO** Fisica Sanitaria, Dipartimento di Scienze Radiologiche, Istituto Scientifico Casa Sollievo della Sofferenza ; San Giovanni Rotondo, Foggia * Fisica, IRCCS Stella Maris ; Pisa ** Neuroradiologia, Dipartimento di Scienze Radiologiche, Istituto Scientifico Casa Sollievo della Sofferenza ; San Giovanni Rotondo, Foggia Key words: 3.0 T MRI, installation, safety, high field MRI INTRODUCTION Despite its high field strength, weight ( kg) and helium load (3.000 l), a 3.0 T magnetic resonance system does not pose special installation problems. Installation of these MR devices is straightforward and no special site preparation is required with respect to lower field strength systems. In addition, the systems are only slightly larger than the 1.5 T imaging units currently in use. It is essential to position the system on a solid base able to absorb gradient vibrations: the device is usually placed on a floor made of concrete, sand and soundproofing material with a total thickness of 40 cm. The possible risks directly correlated to MR diagnostics are mainly linked to three types of electromagnetic field used simultaneously during imaging: the static field, the magnetic field gradients and the RF field. Two other possible sources of indirect risk derive from the intrinsic features of fast superconducting magnets in operation: cryogenic gases and acoustic noise generated by coil vibrations during the MR sequences 1,2,3. Static Field MR investigation is not a high risk diagnostic procedure. Unofficial data on the market as a whole show that around 150,000,000 MR examinations were performed from 1980 to 1999 with an annual estimated rate of 20,000,000 procedures a year equal to around 50,000 a day, and the accidents recorded to date have been rare. Of these, the few severe injuries documented were caused directly by the static magnetic field and consisted of magnetomechanical damage to the patient implants or devices introduced into the scan room by mistake 4,5. Thorough history-taking of patients and installation of a metal detector should rule out the presence of this type of objects as they are extremely dangerous 6,7,8,9,10. Another effect responsible for potential risk, attributed in the past to an abnormal repolarization of the myocardium, is in fact caused by blood flow in the large vessels within a strong magnetic field. This effect has been studied in individuals in fields with a magnetic strength exceeding 8 T showing that the induced potentials are below the threshold of nerve or muscle stimulation. The migration of loads of the opposite sign on vessel walls caused by the magnetic field also produces a current moving perpendicular to the speed of flow in the vessel and hence an additional force in an opposite direction to blood flow due to the magnetic field. In practice, it has been shown that this effect is negligible even in the presence of magnetic fields exceeding 10 T 11. On activating the static magnetic field of the MR system in our institution, the magnetic field was measured using a Hall isotrope detector. The measurements taken at different points in the scan room showed that because of active acoustic screening the dispersed field is limited and in any case much better than that of a 1.5 T MR device of the same type also in use at out institution but lacking active screening. With reference to the magnet s core, the 748

13 A. Maiorana High Field Strength Magnetic Resonance and Safety. Part I. Installation 0.5 mt isomagnet is described by an ellipsoid of semiaxes m and is constrained within the scan room whereas the 200 mt isomagnet is described by an ellipsoid of semiaxes In practice, this is constrained within the magnet s overall dimensions, so that staff can be exposed only partially above the legal limit for the whole body during imaging operations in the MR suite. Hence, limits have not been fixed on the time spent in the scan room by technical personnel, also in view of their limited workload. Thanks to a screen of ferromagnetic slabs, the control panel is only crossed by the 1 mt isomagnet. Variable Fields During MR investigation, patients are also subjected to gradient activation and RF energy impulses sent to generate the signal and decode it. For example, turning the magnetic field gradients on and off can trigger electric currents able to alter the cell membrane potential and, if strong enough, stimulate the peripheral nervous system and cardiac muscle. The threshold of stimulation of peripheral nerves can be painful but is reversible and considered a safety factor with respect to cardiac stimulation which may be hazardous: when the ramp lasts less than 1 ms the first threshold is always below the second 12. In any case, gradient amplitude and duration were carefully set during installation to ensure compliance with the limits fixed by technical guidelines. RF energy impulses are always accompanied by an RF electric field which in turn generates RF electric currents. Due to the Joule effect, these currents can lead to temperature changes potentially harmful to tissues, or burns caused by conductor loops casually triggered by the patient s extremities or belonging to other devices inadvertently left on the patient s skin 13,14,15,16. Technical personnel have been trained to recognize this type of risk which must be carefully addressed during patient preparation. An increase in field strength affects the operative frequency of the MR system and its RF components. At 3.0 T the resonance frequency is 128 Mhz for protons, i.e. double the frequency at 1.5 T, and the spatial distribution of the RF field produced by the coils increases in complexity as the frequency rises. At very high frequencies the wavelength of the field is comparable to the anatomical dimensions under examination and this may lead to the formation of stationary waves which degrade the homogeneity of the RF field and give rise to artefacts which increase as the coil size becomes larger and hence must be adjusted to 3.0 T. In addition, tissue conductivity increases with the rise in frequency thereby raising the density of the induced current: this signifies greater power density deposited in the tissue. High conductivity also means a reduced capacity to penetrate the RF signal and hence the demand for more power to obtain the same result in terms of signal 17. To prevent accidental thermal injury to tissues, the energy deposited per mass unit per time unit, i.e. the SAR (Specific Absorption Rate), should be carefully monitored. To ensure compliance with legislation in force 1, the MR system installed has software for preventive assessment of SAR based on the patient s weight. The scan room is electromagnetically shielded by a Faraday cage supplying an attenuation level of 80 db on a frequency interval from 40 MHz to 130 MHz. The swing doors into the suite are screened and fitted with finger-joint contact and floor battens. The observation window is protected by a thin metal mesh screen. The level of attenuation guaranteed by the a- coustic screening was measured experimentally just after installation close to the observation window, entrance and filter panel using biconic antennae and a spectrum analyzer. Measurements will be repeated every two years. Cryogenic Gases In case of quench, i.e. a sudden increase in the temperature of the magnet coils with violent uncontrolled evaporation of the helium they are immersed in, the oxygen concentration in the imaging suite can drop to values likely to cause asphyxia. The size of the ventilation and helium evacuation system is proportional to the type of magnet and size of the premises. As 700 l of gas are produced for each litre of liquid helium, for a 3.0 T superconducting magnet the 3 m 3 of helium contained in the cryostat in case of quench must leave the imaging suite as quickly as possible. The system guarantees at least 20 changes of air/hour under emergency conditions and the cross section area of the exhaust pipe is 749

14 High Field Strength Magnetic Resonance and Safety. Part I. Installation A. Maiorana proportional to the length of the pipe and the number of elbows. An oxygen level sensor is positioned high up in the room close to the most likely point of leakage. The oxygen level indicator is located outside the suite near the control panel. The delivery and pull-out points have been designed to avoid a short-circuit. The inlet of clean air from outside is proportional to the suction rate. To avoid transporting cryogenic gas containers inside the hospital, an insulated pipe allows the helium to be refilled directly from outside the building. Refilling is carried out only twice a year on average (1.200 l) due to the low consumption of helium. Acoustic Noise The magnetic field gradients are the main source of acoustic noise in an MR device. Noise is caused by the rapid changes in current inside the coils which are subject to Lorentz force in the presence of a strong magnetic field. Gradient changes in amplitude and ramping caused by different types of sequences can affect the noise level. Noise increases when the s- lice thickness, field of view, TR and TE are reduced 18. Ear plugs are available in the scan room to protect patients hearing during particularly noisy sequences. Quality Control Quality control is essential for effective diagnosis. This applies to MR systems in general, e- specially the new MR devices whose performance is largely the result of a balance of optimal conditions established during installation. In addition to checking the electrical safety of the new system, the manufacturer also carried out a series of tests designed to ascertain the minimum specifications of diagnostic quality for the device including congruent slice thickness, uniformity and signal/noise ratio. Some of parameters are repeated during periodic maintenance testing. In addition to the manufacturer s checks, a quality control protocol has been devised based on the quality control system proposed by the COMAC BME group to monitor key parameters for the purposes of ongoing diagnostic quality. Measurements were carried out on the Eurospin set of test objects produced by Diagnostic Sonar Ltd, comprising the signal/noise ratio, uniformity, slice profile and width and the presence of artefacts 19,20. References 1 Comitato Elettrotecnico Italiano, Apparecchi Elettromedicali. Parte 2: Prescrizioni particolari di sicurezza relative agli apparecchi a risonanza magnetica per diagnostica medica. CEI EN , The International Commission on Non-Ionizing Radiation Protection [ICNIRP], Medical Magnetic Resonance (MR) Procedures: Protection of Patients, Health Physics 87: Food and Drug Administration Center for Devices and Radiological Health, Criteria for Significant Risk Investigations of Magnetic Resonance Diagnostic Devices Kangarlu A, Robitaille P-ML: Biological Effects and Health Implications in Magnetic Resonance Imaging. Concepts in Magnetic Resonance 12: 5, Schenck JF: Safety of Strong, Static Magnetic Fields. Journal of Magnetic Resonance Imaging 12: Shellock FG: Magnetic Resonance Safety Update 2002: Implants and Devices. Journal of Magnetic Resonance Imaging 16: Shellock FG: Biomedical Implants and Devices: Assessment of Magnetic Field Interactions with a 3.0 Tesla MR System. Journal of Magnetic Resonance Imaging 16: Duru F et Al: Pacing in magnetic resonance imaging environment: clinical and technical considerations on compatibility. European Heart Journal 22: Shellock F et Al: Cardiac Pacemakers, ICDs, and Loop Recorder: Evaluation of Translational Attraction Using Conventional (Long Bore) and Short Bore 1.5 and 3.0 Tesla MR Systems. Journal of Cardiovascular Magnetic Resonance 5: 2, Kangarlu a, Shellock FG: Aneurysm Clips: Evaluation of Magnetic Field Interactions with an 8.0 T MR System. Journal of Magnetic Resonance Imaging12: Kangarlu A et Al. Cognitive, Cardiac, and Physiological Safety Studies in Ultra High Field Magnetic Resonance Imaging. Magnetic Resonance Imaging 17: 10, Schaefer D.J. et al. Review of Patient Safety in Time Varying Gradient Field. Journal of Magnetic Resonance Imaging, 12, Shellock FG, Crues JV: Corneal temperature changes induced by high-field-strength MR imaging with a head coil. Radiology 167:

15 www. centauro. it Rivista di Neuroradiologia 17: , Knopp MV, Essig M, Debus J et Al: Unusual burns of the lower extremities caused by a closed conducting loop in a patient at MR imaging. Radiolog: 200, Shellock FG, Slimp GL: Severe burn of the finger caused by using a pulse oxymeter during MR imaging (letter). Am J Radiol 5: Mary F. Dempsey, Barrie Condon Thermal Injuries Associated with MRI. Clinical Radiology, 56, Frayne R et Al: Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging. Investigative Radiology 38: 7, McJury M, Shellock FG: Auditory Noise Associated with MR Procedures: A Review. Journal of Magnetic Resonance Imaging 12, Podo F: Controlli di qualità nella risonanza magnetica ad uso clinico. Ann. Ist. Super. Sanità 30: Lerski RA: Trial of modifications to Eurospin MRI test objects, Magnetic Resonance Imaging 11: Dr T. Scarabino Neuroradiologia Dipartimento di Scienze Radiologiche Istituto Scientifico Casa Sollievo della Sofferenza Viale Cappuccini, San Giovanni Rotondo - FG Tel

FDA Guidelines for Magnetic Resonance Equipment Safety

FDA Guidelines for Magnetic Resonance Equipment Safety FDA Guidelines for Magnetic Resonance Equipment Safety Loren A. Zaremba, Ph.D. Center for Devices and Radiological Health Food and Drug Administration Outline I. Introduction II. Static Magnetic Field

More information

Human Exposure Limits

Human Exposure Limits Human Exposure Limits Session 3 0 Version December 2014 Learning objectives In this session we will: Learn about the international exposure limits for workers and the public Learn about methods for assessing

More information

MRI SAFETY JEOPARDY (Technologist Edition) Questions

MRI SAFETY JEOPARDY (Technologist Edition) Questions MRI SAFETY JEOPARDY (Technologist Edition) Questions For MRI Safety Week, 2009 Provided, Inc. www.mednovus.com PowerPoint MRI Safety Quiz available for free download from http://mrimetaldetector.com/media/proving_grounds/mri_safety_week.html

More information

Official Journal of the European Communities. (Acts whose publication is not obligatory) COUNCIL

Official Journal of the European Communities. (Acts whose publication is not obligatory) COUNCIL 30. 7. 1999 EN Official Journal of the European Communities L 199/59 II (Acts whose publication is not obligatory) COUNCIL COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general

More information

COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC)

COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC) COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC) THE COUNCIL OF THE EUROPEAN UNION, Having regard to

More information

Technique and Safety of. by Pierluigi Castellone, Electronics Engineer Brain Products General Manager

Technique and Safety of. by Pierluigi Castellone, Electronics Engineer Brain Products General Manager Technique and Safety of performing EEG/fMRI measurements by Pierluigi Castellone, Electronics Engineer Brain Products General Manager Contents of the presentation Why recording simultaneous EEG and fmri?

More information

Advanced MRI methods in diagnostics of spinal cord pathology

Advanced MRI methods in diagnostics of spinal cord pathology Advanced MRI methods in diagnostics of spinal cord pathology Stanisław Kwieciński Department of Magnetic Resonance MR IMAGING LAB MRI /MRS IN BIOMEDICAL RESEARCH ON HUMANS AND ANIMAL MODELS IN VIVO Equipment:

More information

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System 1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System NEVRO CORP. All questions or concerns about Nevro products should be forwarded to: Nevro Corp. 1800 Bridge Parkway

More information

SR Communications Tower Task Force Dr. Jeff Liva, Allen Cohen, Rebecca Rogers

SR Communications Tower Task Force Dr. Jeff Liva, Allen Cohen, Rebecca Rogers SR Communications Tower Task Force Dr. Jeff Liva, Allen Cohen, Rebecca Rogers 1 Table of Contents 2 Chemical hazards. These develop from excessive exposure to concentrations of chemicals in environment.

More information

Selected Radio Frequency Exposure Limits

Selected Radio Frequency Exposure Limits ENVIRONMENT, SAFETY & HEALTH DIVISION Chapter 50: Non-ionizing Radiation Selected Radio Frequency Exposure Limits Product ID: 94 Revision ID: 1736 Date published: 30 June 2015 Date effective: 30 June 2015

More information

Wireless Broadband: Health & Safety Information

Wireless Broadband: Health & Safety Information Wireless Broadband: Health & Safety Information Introduction The increasing use of mobile phones and other wireless technology has been accompanied by public debate about possible adverse effects on health.

More information

Numerical Modelling of E-M Occupational Exposures associated with MRI

Numerical Modelling of E-M Occupational Exposures associated with MRI Numerical Modelling of E-M Occupational Exposures associated with MRI Jeff Hand and Yan Li Imaging Sciences Dept, Imperial College London, Hammersmith Hospital Campus Physical Agents Directive (EMFs) 2004/40/EC

More information

Projects at the Danish Research Centre for Magnetic Resonance

Projects at the Danish Research Centre for Magnetic Resonance Projects at the Danish Research Centre for Magnetic Resonance Five projects involving Magnetic Resonance Imaging (MRI) Hvidovre Hospital Example: [1-13C]Pyruvate signal enhanced by ~50,000x! Magnetic Resonance

More information

Functional neuroimaging. Imaging brain function in real time (not just the structure of the brain).

Functional neuroimaging. Imaging brain function in real time (not just the structure of the brain). Functional neuroimaging Imaging brain function in real time (not just the structure of the brain). The brain is bloody & electric Blood increase in neuronal activity increase in metabolic demand for glucose

More information

REVEAL LINQ LNQ11. Insertable Cardiac Monitor MRI procedural information. MRI Technical Manual

REVEAL LINQ LNQ11. Insertable Cardiac Monitor MRI procedural information. MRI Technical Manual REVEAL LINQ LNQ11 Insertable Cardiac Monitor MRI procedural information MRI Technical Manual Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list

More information

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time Module 8: IQ: Acquisition Time IQ : Acquisition Time Objectives...Describe types of data acquisition modes....compute acquisition times for 2D and 3D scans. 2D Acquisitions The 2D mode acquires and reconstructs

More information

2012 Operating Room Design Manual

2012 Operating Room Design Manual CHAPTER 16 REMOTE AND HAZARDOUS LOCATIONS Lead Author: John Rogoski, DO, Assistant Professor of Clinical Anesthesiology, Ohio State University College of Medicine Checklist: Is the room size large enough

More information

ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System

ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician. 91035972-01

More information

Magnetic Resonance Imaging

Magnetic Resonance Imaging Magnetic Resonance Imaging North American Spine Society Public Education Series What Is Magnetic Resonance Imaging (MRI)? Magnetic resonance imaging (MRI) is a valuable diagnostic study that has been used

More information

EMR Exposure Limits & Assessment Methods for Mobile Phone Communications. Lindsay Martin Manager, Non-Ionising Radiation Section

EMR Exposure Limits & Assessment Methods for Mobile Phone Communications. Lindsay Martin Manager, Non-Ionising Radiation Section EMR Exposure Limits & Assessment Methods for Mobile Phone Communications Lindsay Martin Manager, Non-Ionising Radiation Section Introduction How can we use Wireless Communication Safely? Wireless communication

More information

Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications)

Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications) Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications) Excelart Vantage Magnet Configuration: Ultra-short-bore Strength (or W x H): 1.5 T Homogeneity, ppm V-RMS: Dimensions of maximum

More information

THE ANSI/IEEE RF SAFETY STANDARD AND ITS RATIONALE. Om P. Gandhi and Gianluca Lazzi Department of Electrical Engineering Salt Lake City, Utah 84112

THE ANSI/IEEE RF SAFETY STANDARD AND ITS RATIONALE. Om P. Gandhi and Gianluca Lazzi Department of Electrical Engineering Salt Lake City, Utah 84112 Introduction THE ANSI/IEEE RF SAFETY STANDARD AND ITS RATIONALE Om P. Gandhi and Gianluca Lazzi Department of Electrical Engineering Salt Lake City, Utah 84112 In 1960, the American Standards Association

More information

NeuroStar TMS Therapy Patient Guide for Treating Depression

NeuroStar TMS Therapy Patient Guide for Treating Depression NeuroStar TMS Therapy Patient Guide for Treating Depression This NeuroStar TMS Therapy Patient Guide for Treating Depression provides important safety and use information for you to consider about treating

More information

Prepublication Requirements

Prepublication Requirements Issued Prepublication Requirements The Joint Commission has approved the following revisions for prepublication. While revised requirements are published in the semiannual updates to the print manuals

More information

Specific Absorption Rate (SAR) in the head of Tablet user's

Specific Absorption Rate (SAR) in the head of Tablet user's 7th Latin American Workshop On Communications - 2015 Specific Absorption Rate (SAR) in the head of Tablet user's Juliana Borges Ferreira Post-graduation program in Electrical Engineering Federal University

More information

Embedded Systems in Healthcare. Pierre America Healthcare Systems Architecture Philips Research, Eindhoven, the Netherlands November 12, 2008

Embedded Systems in Healthcare. Pierre America Healthcare Systems Architecture Philips Research, Eindhoven, the Netherlands November 12, 2008 Embedded Systems in Healthcare Pierre America Healthcare Systems Architecture Philips Research, Eindhoven, the Netherlands November 12, 2008 About the Speaker Working for Philips Research since 1982 Projects

More information

RICHARD T ELL ASSOCIATES,INC.

RICHARD T ELL ASSOCIATES,INC. RICHARD T ELL ASSOCIATES,INC. An Evaluation of Test Measurement Data Obtained on the KW-Gard RF Protective Suit March 30, 1998 Prepared for Euclid Garment Manufacturing Company 333 Martinel Drive Kent,

More information

Advanced Measurements of Microwave Oven Leakage

Advanced Measurements of Microwave Oven Leakage Conference paper Advanced Measurements of Microwave Oven Leakage M. Bangay [1] C. Zombolas [2] 1. Australian Radiation Protection and Nuclear Safety Agency 2. EMC Technologies Pty Ltd Abstract Reports

More information

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless)

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless) 1 2 The range of RF spans 3 KHz (3000 Hz) to 300 GHz (300 million Hz) Frequencies of RF devices range from the low frequency AM broadcasts (80 MHz) to higher frequency mobile phones (1900 MHz) smart meters

More information

Chemistry Department

Chemistry Department Chemistry Department NMR/Instrumentation Facility Users Guide - Rules, safety and system information Prepared by Leila Maurmann The NMR/Instrumentation facility at the Chemistry Department at Kansas State

More information

Subject: Magnet Safety. Overview: Environmental Health & Safety Policy/Procedure Effective Date: July 29, 2011

Subject: Magnet Safety. Overview: Environmental Health & Safety Policy/Procedure Effective Date: July 29, 2011 Subject: Magnet Safety Environmental Health & Safety Policy/Procedure Overview: The purpose of this document is to define and clarify policies associated with the use of magnets and magnetic fields at

More information

Thermal Effects of Mobile Phones

Thermal Effects of Mobile Phones Thermal Effects of Mobile Phones S. Kassimi 1, A. ELfadl, S. Bri 3, A. Nakheli 4, M. Habibi 5, M. Ben Ahmed 6 Systems and Telecommunications Engineering Decision Laboratory,Ibn Tofail University, Faculty

More information

ELECTROMAGNETIC FIELDS AND PUBLIC HEALTH HEALTH AND SAFETY GUIDELINES #1

ELECTROMAGNETIC FIELDS AND PUBLIC HEALTH HEALTH AND SAFETY GUIDELINES #1 SINGAPORE, 16 AUGUST 2001 HEALTH SCIENCES AUTHORITY PRESS RELEASE ELECTROMAGNETIC FIELDS AND PUBLIC HEALTH HEALTH AND SAFETY GUIDELINES #1 THE EMF HEALTH ISSUE 1 Over the past years a large number of scientific

More information

Table 11: Pros and Cons of 1.5 T MRI vs. 3.0 T MRI; Safety and Technical Issues, and Clinical Applications

Table 11: Pros and Cons of 1.5 T MRI vs. 3.0 T MRI; Safety and Technical Issues, and Clinical Applications Safety Issue 3.0 T MRI Pro 3.0 T MRI Con Immediate fringe field surrounding magnet A ferromagnetic object inadvertently brought into the scan room will experience a sharp increase in attraction toward

More information

The Effects of Ultrasonic Sound Generated by Ultrasonic Cleaning Systems on Human Hearing and Physiology

The Effects of Ultrasonic Sound Generated by Ultrasonic Cleaning Systems on Human Hearing and Physiology The Effects of Ultrasonic Sound Generated by Ultrasonic Cleaning Systems on Human Hearing and Physiology Questions about the effects of ultrasonic energy on hearing and other human physiology arise from

More information

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz J. Klima, R. Ščehovič Department of Physics, Faculty of Natural Sciences, University of Mathias Bel, Tajovského

More information

Electromagnetic Field Safety

Electromagnetic Field Safety SAR A Basic Restriction for Electromagnetic Field Safety David Baron, PE Consulting Engineer Electromagnetic Field Safety d.baron@ieee.org NOTE. CENAM is not responsible for the content of this document.

More information

MRI Department Goals. Effective Ways to Improve Patient Cooperation and Safety in MRI Exam. Lecture Topics

MRI Department Goals. Effective Ways to Improve Patient Cooperation and Safety in MRI Exam. Lecture Topics Effective Ways to Improve Patient Cooperation and Safety in MRI Exam lowens2@clarian.org Lecture Topics MRI patient preparation Department MRI Safety Policies and Procedures MRI patient safety screening

More information

Effect of Metallic Materials on SAR

Effect of Metallic Materials on SAR Contemporary Engineering Sciences, Vol. 5, 2012, no. 9, 407-411 Effect of Metallic Materials on SAR Asma Lak Department of Electrical Engineering, Genaveh branch Islamic Azad University, Genaveh, Iran

More information

5 Factors Affecting the Signal-to-Noise Ratio

5 Factors Affecting the Signal-to-Noise Ratio 5 Factors Affecting the Signal-to-Noise Ratio 29 5 Factors Affecting the Signal-to-Noise Ratio In the preceding chapters we have learned how an MR signal is generated and how the collected signal is processed

More information

MRET-Shield Synopsis of Scientific Research Updated on June 1, 2007

MRET-Shield Synopsis of Scientific Research Updated on June 1, 2007 MRET-Shield Synopsis of Scientific Research Updated on June 1, 27 MRET-Shield material and devices made, when placed in proximity to persons, animals and plants serve to lessen adverse health effects caused

More information

MRI Safety at 3T versus 1.5T

MRI Safety at 3T versus 1.5T The Internet Journal of World Health and Societal Politics TM MRI Safety at 3T versus 1.5T Jennifer Jerrolds R.T.(R)(CT)(MR) Shane Keene MBA, RRT-NPS, CPFT, RPSGT Citation: Jennifer Jerrolds & Shane Keene:

More information

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Craig W. Fanning Elite Electronic Engineering, Inc. 1516 Centre Circle Downers

More information

MAGNETIC FIELD SAFETY MANUAL

MAGNETIC FIELD SAFETY MANUAL Draft - January 10, 2012 Table of Contents Scope and Purpose... 3 Abbreviations... 5 Glossary of Terms / Definitions... 6 Concordia University Administrative Structure... 9 1. University Radiation Safety

More information

Magnetic Resonance Imaging

Magnetic Resonance Imaging PRIMARY CERTIFICATION DIDACTIC AND CLINICAL COMPETENCY REQUIREMENTS EFFECTIVE JANUARY 2014 Magnetic Resonance Imaging 1. Introduction Candidates for certification and registration are required to meet

More information

REGULATORY IMPACT ANALYSIS (RIA) SAFETY, HEALTH AND WELFARE AT WORK. (Electromagnetic Fields) REGULATIONS 2016. (S.I. No. of 2016) 5 th January 2015

REGULATORY IMPACT ANALYSIS (RIA) SAFETY, HEALTH AND WELFARE AT WORK. (Electromagnetic Fields) REGULATIONS 2016. (S.I. No. of 2016) 5 th January 2015 REGULATORY IMPACT ANALYSIS (RIA) SAFETY, HEALTH AND WELFARE AT WORK (Electromagnetic Fields) REGULATIONS 2016 (S.I. No. of 2016) 5 th January 2015 EMF Regulations Page 1 Contents 1.Foreword...2 2.Policy

More information

A Primer on Medical Device Interactions with Magnetic Resonance Imaging Systems

A Primer on Medical Device Interactions with Magnetic Resonance Imaging Systems This guidance was written prior to the February 27, 1997 implementation of FDA's Good Guidance Practices, GGP's. It does not create or confer rights for or on any person and does not operate to bind FDA

More information

Safety Guidelines for Magnetic Resonance Imaging Equipment in Clinical Use

Safety Guidelines for Magnetic Resonance Imaging Equipment in Clinical Use Safety Guidelines for Magnetic Resonance Imaging Equipment in Clinical Use March 2015 Safety Guidelines for Magnetic Resonance Imaging Equipment in Clinical Use 1/86 Acknowledgements The following are

More information

Effects of Cell Phone Radiation on the Head. BEE 4530 Computer-Aided Engineering: Applications to Biomedical Processes

Effects of Cell Phone Radiation on the Head. BEE 4530 Computer-Aided Engineering: Applications to Biomedical Processes Effects of Cell Phone Radiation on the Head BEE 4530 Computer-Aided Engineering: Applications to Biomedical Processes Group 3 Angela Cai Youjin Cho Mytien Nguyen Praveen Polamraju Table of Contents I.

More information

IMAGO7, B1 and Local SAR evaluation

IMAGO7, B1 and Local SAR evaluation Centro di ricercasullebiotecnologie di risonanza magnetica a campo ultra alto www.imago7.eu IMAGO7, the first Italian 7T MR scanner: B1 and Local SAR evaluation Gianluigi Tiberi INRIM, Febbraio 2014 THE

More information

MRI SAFETY JEOPARDY (NON Technologist Edition) Questions

MRI SAFETY JEOPARDY (NON Technologist Edition) Questions MRI SAFETY JEOPARDY (NON Technologist Edition) Questions For MRI Safety Week, 2009 Provided, Inc. www.mednovus.com PowerPoint MRI Safety Quiz available for free download from http://mrimetaldetector.com/media/proving_grounds/mri_safety_week.html

More information

Environmental Health and Safety

Environmental Health and Safety Environmental Health and Safety Standard Operating Guideline RF & Microwave Safety Program 1.0 Purpose and Requirements This guide will present a summary of the basics of radiofrequency (RF) and microwave

More information

YOUR MRI EXAM: QUESTIONS AND ANSWERS

YOUR MRI EXAM: QUESTIONS AND ANSWERS YOUR MRI EXAM: QUESTIONS AND ANSWERS What is MRI? MRI is short for Magnetic Resonance Imaging. MRI is an advanced technology that lets your doctor see internal organs, blood vessels, muscles, joints, tumors,

More information

The Existing Public Exposure Standards Cindy Sage, MA Sage Associates, USA

The Existing Public Exposure Standards Cindy Sage, MA Sage Associates, USA SECTION 3 _ The Existing Public Exposure Standards Cindy Sage, MA Sage Associates, USA Prepared for the BioInitiative Working Group August 2007 The US Federal Communications Commission (FCC) Exposure Standard

More information

What are radio signals?

What are radio signals? Mobile phones and other wireless technologies have become an integral part of everyday life. But does using a mobile phone regularly, or living near a base station, have any implications for our health?

More information

Magnetic Resonance Imaging: Health Effects and Safety

Magnetic Resonance Imaging: Health Effects and Safety Magnetic Resonance Imaging: Health Effects and Safety Kwan-Hoong Ng, Azlan C Ahmad, MS Nizam, BJJ Abdullah Department of Radiology University of Malaya Kuala Lumpur Malaysia ngkh@um.edu.my ABSTRACT Magnetic

More information

5162 E. Working in oxygen-reduced atmospheres BGI/GUV-I 5162 E. Information

5162 E. Working in oxygen-reduced atmospheres BGI/GUV-I 5162 E. Information 5162 E BGI/GUV-I 5162 E Information Working in oxygen-reduced atmospheres November 2013 Imprint About us Publisher: German Social Accident Insurance (DGUV) Mittelstraße 51 10117 Berlin Tel.: 030 288763800

More information

Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements

Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements Jagadish Nadakuduti, Lin Lu, Paul Guckian Qualcomm Technologies,

More information

Statement of the Chief Medical Health Officer

Statement of the Chief Medical Health Officer Statement of the Chief Medical Health Officer June, 2011 Health Concerns About Cellular Phone Transmission Antennae and Base Stations In 2005, in response to community concerns and after reviewing the

More information

Principles of Medical Ultrasound. Pai-Chi Li Department of Electrical Engineering National Taiwan University

Principles of Medical Ultrasound. Pai-Chi Li Department of Electrical Engineering National Taiwan University Principles of Medical Ultrasound Pai-Chi Li Department of Electrical Engineering National Taiwan University What is Medical Ultrasound? Prevention: actions taken to avoid diseases. Diagnosis: the process

More information

Magnetic Resonance Imaging Environment Safety in Ontario

Magnetic Resonance Imaging Environment Safety in Ontario Magnetic Resonance Imaging Environment Safety in Ontario April 2006 Healthcare Human Factors Group University Health Network Table of Contents List of Abbreviations 1 List of Units 1 Definitions 2 Executive

More information

BIOMEDICAL ULTRASOUND

BIOMEDICAL ULTRASOUND BIOMEDICAL ULTRASOUND Goals: To become familiar with: Ultrasound wave Wave propagation and Scattering Mechanisms of Tissue Damage Biomedical Ultrasound Transducers Biomedical Ultrasound Imaging Ultrasonic

More information

Internal and External Accident Incident Reporting

Internal and External Accident Incident Reporting Phoenix Community Care Ltd Policy & Procedure Internal and External Accident Incident Reporting Version Written Updated Scheduled Review Date Author 1 2008 2008 2009 Anne Spriggs 2 2010 2013 Angela Kelly

More information

AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS

AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS Annamaria PALJANOS, paljanosanna@yahoo.com Călin MUNTEANU calin.munteanu@et.utcluj.ro TECHNICAL UNIVERSITY CLUJ NAPOCA,

More information

Enabling Faster, Better Medical Device Development and Evaluation with Modeling and Simulation Tina Morrison PhD

Enabling Faster, Better Medical Device Development and Evaluation with Modeling and Simulation Tina Morrison PhD Enabling Faster, Better Medical Device Development and Evaluation with Modeling and Simulation Tina Morrison PhD Office of Device Evaluation Center for Devices and Radiological Health U.S. Food and Drug

More information

EFFECTS OF ELECTROMAGNETIC RADIATION FROM MOBILE PHONES AND CASE STUDIES OF COMPUTATIONAL MODELS FOR CALCULATING SAR DISTRIBUTION IN HUMAN BODY Settapong Malisuwan National Broadcasting and Telecommunications

More information

What You Should Know About Cerebral Aneurysms

What You Should Know About Cerebral Aneurysms What You Should Know About Cerebral Aneurysms From the Cerebrovascular Imaging and Interventions Committee of the American Heart Association Cardiovascular Radiology Council Randall T. Higashida, M.D.,

More information

Basic Principles of Magnetic Resonance

Basic Principles of Magnetic Resonance Basic Principles of Magnetic Resonance Contents: Jorge Jovicich jovicich@mit.edu I) Historical Background II) An MR experiment - Overview - Can we scan the subject? - The subject goes into the magnet -

More information

What the experts say: The consensus of scientific opinion

What the experts say: The consensus of scientific opinion What the experts say: The consensus of scientific opinion AMTA relies on the expert judgment of independent public health authorities, such as the World Health Organization, for assessments of safety and

More information

Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions

Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions M. R. Iqbal-Faruque* 1, N. Aisyah-Husni 2, Md. Ikbal-Hossain 1, M. Tariqul-Islam 2 and N. Misran 2 1

More information

Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone

Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone , June 30 - July 2, 2010, London, U.K. Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone Adel Z. El Dein Alaeddin Amr Abstract - This paper analyzes the specific

More information

ASSESSMENT OF MAGNETIC RESONANCE IMAGING PROTOCOLS WITH HEALTHY VOLUNTEERS

ASSESSMENT OF MAGNETIC RESONANCE IMAGING PROTOCOLS WITH HEALTHY VOLUNTEERS SHEFC BRAIN IMAGING RESEARCH CENTRE FOR SCOTLAND Department of Clinical Neurosciences The University of Edinburgh Western General Hospital Crewe Road Edinburgh EH4 2XU Tel: 0131 537 2664 Fax: 0131 537

More information

Regulation for wireless telecommunication equipment

Regulation for wireless telecommunication equipment Wireless devices Regulation for wireless telecommunication equipment * Wireless home telephones * Baby monitors * Wireless on the Internet * Bluetooth * Comparison of SAR values Introduction Do you wonder

More information

Procedures/risks: Radiology (CT, DXA, MRI, ultrasound, X-ray)

Procedures/risks: Radiology (CT, DXA, MRI, ultrasound, X-ray) Procedures/risks: Radiology (CT, DXA, MRI, ultrasound, X-ray) Computerized Axial Tomography (CT): Procedure: A Computerized Axial Tomography (CT) scan [of your heart] involves holding your breath for a

More information

How can I be sure it will be performed to a high standard?

How can I be sure it will be performed to a high standard? FREQUENTLY ASKED QUESTIONS (About ultrasound scans at Derriford) What is an Ultrasound Scan? How does it work? What are the dangers? What are the advantages? Who will perform my scan? How can I be sure

More information

Introduction to Industrial Hygiene for the Safety Professional

Introduction to Industrial Hygiene for the Safety Professional Introduction to Industrial Hygiene for the Safety Professional Jeffery K. Dennis, MS, CSP, CHMM, CET, CSSM, WSO-CSE Welcome Today we will introduce and discuss the elements of effective Industrial Hygiene

More information

A Patient s Guide to Minimally Invasive Abdominal Aortic Aneurysm Repair

A Patient s Guide to Minimally Invasive Abdominal Aortic Aneurysm Repair A Patient s Guide to Minimally Invasive Abdominal Aortic Aneurysm Repair Table of Contents The AFX Endovascular AAA System............................................ 1 What is an Abdominal Aortic Aneurysm

More information

BLM Emerging Risks Team - Report on Mobile Phones/EMFs

BLM Emerging Risks Team - Report on Mobile Phones/EMFs BLM Emerging Risks Team - Report on Mobile Phones/EMFs November 2014 Malcolm Keen Solicitor, BLM London T 020 7865 3381 E Malcolm.keen@blmlaw.com 1 Introduction Use of mobile phones has of course increased

More information

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS RF EXPOSURE LIMITS AND TESTING REQUIREMENTS Jay Moulton Vice President March 12, 2013 1 OVERVIEW Specific Absorption Rate (SAR) and Maximum Permissible Exposure (MPE) Standards and Limits Evaluation Methods

More information

Prior to commencing a research study, the necessary approval must be obtained from:

Prior to commencing a research study, the necessary approval must be obtained from: CENTRE FOR COGNITIVE NEUROIMAGING MRI SCANNING SUITE PROCEDURES The MRI suite at the Centre for Cognitive Neuroimaging (CCNi), houses a Siemens 3T Tim Trio MRI scanner. Neuroimaging research studies are

More information

What Is an Arteriovenous Malformation (AVM)?

What Is an Arteriovenous Malformation (AVM)? What Is an Arteriovenous Malformation (AVM)? From the Cerebrovascular Imaging and Intervention Committee of the American Heart Association Cardiovascular Council Randall T. Higashida, M.D., Chair 1 What

More information

ARIB TR-T12-34.925 V3.0.0. Specific Absorption Rate (SAR) requirements and regulations in different regions

ARIB TR-T12-34.925 V3.0.0. Specific Absorption Rate (SAR) requirements and regulations in different regions ARIB TR-T12-34.925 V3.0.0 Specific Absorption Rate (SAR) requirements and regulations in different regions Refer to "Notice" in the preface of ARIB TR-T12 for Copyrights. Technical Report 3rd Generation

More information

Investigation of Magnetic Resonance Imaging Effects when Using Bone Conduction Implants

Investigation of Magnetic Resonance Imaging Effects when Using Bone Conduction Implants Investigation of Magnetic Resonance Imaging Effects when Using Bone Conduction Implants Master of Science Thesis in Biomedical Engineering, MPBME Karl-Johan Fredén Jansson Department of Signals and Systems

More information

Development of Radiation Resistant Quadrupoles Based on High Temperature Superconductors for the Fragment Separator

Development of Radiation Resistant Quadrupoles Based on High Temperature Superconductors for the Fragment Separator Development of Radiation Resistant Quadrupoles Based on High Temperature Superconductors for the Fragment Separator R. Gupta and M.Harrison, Brookhaven National Laboratory A. Zeller, Michigan State University

More information

Magnetic Resonance Imaging

Magnetic Resonance Imaging Magnetic Resonance Imaging What are the uses of MRI? To begin, not only are there a variety of scanning methodologies available, but there are also a variety of MRI methodologies available which provide

More information

Ministero della Salute

Ministero della Salute Ministero della Salute Direzione Generale della Ricerca e dell' Innovazione in Sanità BANDO 2013 PROGRAMMI DI RETE FINANZIATI PROGRAMMA NETWORK CODICE: 02356160 SCORE MEDIO DEL NETWORK: 13,75 Pediatric

More information

RF safety at base station sites

RF safety at base station sites RF safety at base station sites CONTENTS 1 Purpose and scope................................................. 2 2 Introduction........................................................ 2 3 Basic information...................................................

More information

Transcutaneous Electrical Nerve Stimulation Device LUMI-TENS

Transcutaneous Electrical Nerve Stimulation Device LUMI-TENS Transcutaneous Electrical Nerve Stimulation Device LUMI-TENS Operation Manual Read Before Using LUMI-TENS-INS-LAB-RevA08 TABLE OF CONTENTS INTRODUCTION TO TENS INDICATIONS AND CONTRAINDICATIONS WARNINGS

More information

Omni Antenna vs. Directional Antenna

Omni Antenna vs. Directional Antenna Omni Antenna vs. Directional Antenna Document ID: 82068 Contents Introduction Prerequisites Requirements Components Used Conventions Basic Definitions and Antenna Concepts Indoor Effects Omni Antenna Pros

More information

EXPOSURE INDICES IN RF EPIDEMIOLOGY

EXPOSURE INDICES IN RF EPIDEMIOLOGY EXPOSURE INDICES IN RF EPIDEMIOLOGY Paolo Vecchia National Institute of Health, Rome, Italy Advances in Biological effects and Dosimetry of Low Energy Electromagnetic Fields Erice, 28 March - 8 April 1981

More information

Living with Your Pacemaker

Living with Your Pacemaker Brief Statement Additional Device Information An implantable pacemaker system relieves symptoms of heart rhythm disturbances. They do this by restoring normal heart rates. A normal heart rate provides

More information

Mobile communication and health. Simply A1.

Mobile communication and health. Simply A1. Mobile communication and health Simply A1. For mobility and safety 5.9 billion people worldwide use mobile phones. For most of us, the mobile phone has become an indispensable part of our lives: In Austria

More information

Steps to getting a diagnosis: Finding out if it s Alzheimer s Disease.

Steps to getting a diagnosis: Finding out if it s Alzheimer s Disease. Steps to getting a diagnosis: Finding out if it s Alzheimer s Disease. Memory loss and changes in mood and behavior are some signs that you or a family member may have Alzheimer s disease. If you have

More information

AP Psychology ~ Ms. Justice

AP Psychology ~ Ms. Justice AP Psychology ~ Ms. Justice 8: What are the characteristics of air pressure waves that we hear as sound? Audition Audition, or hearing, is highly adaptive. We hear a wide range of sounds, but we hear best

More information

Keywords Mobile Tower Radiations, Electromagnetic Radiations, Signal Strength, Mobile Phone

Keywords Mobile Tower Radiations, Electromagnetic Radiations, Signal Strength, Mobile Phone Volume 5, Issue 1, January 2015 ISSN: 2277 128X International Journal of Advanced Research in Computer Science and Software Engineering Research Paper Available online at: www.ijarcsse.com Analysis of

More information

Imaging Markers of Brain Network Dysfunction in Multiple Sclerosis

Imaging Markers of Brain Network Dysfunction in Multiple Sclerosis Faculty of Medicine & Health Sciences School of Medicine Radiological Sciences Research Group The University of Nottinham University Park Nottingham NG7 2RD t: +44 (0)115 823 0018 f: +44 (0)115 823 0004

More information

COMPARATIVE STUDY OF THE EFFECT OF MICROWAVE RADIATION NEUTRALIZERS ON PHYSIOLOGICAL STATE OF HUMAN SUBJECTS

COMPARATIVE STUDY OF THE EFFECT OF MICROWAVE RADIATION NEUTRALIZERS ON PHYSIOLOGICAL STATE OF HUMAN SUBJECTS COMPARATIVE STUDY OF THE EFFECT OF MICROWAVE RADIATION NEUTRALIZERS ON PHYSIOLOGICAL STATE OF HUMAN SUBJECTS Igor Smirnov, Ph. D. and M. S. 2005 All Copyrights reserved by I.Smirnov Affiliation: GLOBAL

More information

Mr. Richard Tell Chair, IEEE SCC28 (SC4) Risk Assessment Work Group Richard Tell Associates, Inc. 8309 Garnet Canyon Lane Las Vegas, NV 89129-4897

Mr. Richard Tell Chair, IEEE SCC28 (SC4) Risk Assessment Work Group Richard Tell Associates, Inc. 8309 Garnet Canyon Lane Las Vegas, NV 89129-4897 DEPARTMENT OF HEALTH AND HUMAN SERVICES Public Health Service National Institute for Occupational Safety and Health Robert A. Taft Laboratories 4676 Columbia Parkway Cincinnati OH 45226-1998 June 17, 1999

More information

GE 3.0T NPW,TRF,FAST,F R NPW,TRF,FAST,F R

GE 3.0T NPW,TRF,FAST,F R NPW,TRF,FAST,F R GE 3.0T 3.0T WRIST Invivo 8CH Wrist Coil Sequence Ax T2 Cor PD Cor PDFS Cor T1 Cor PD (Small FOV) FOV (mm) 80 80 80 80 40 Matrix 384x224 384x256 320x256 384x320 320x192 Phase Direction RL RL RL RL RL #

More information