MICROORGANIC POLLUTANTS: ACTION NEEDED TO SIMPLIFY THEIR ANALYSIS

Size: px
Start display at page:

Download "MICROORGANIC POLLUTANTS: ACTION NEEDED TO SIMPLIFY THEIR ANALYSIS"

Transcription

1 MICROORGANIC POLLUTANTS: ACTION NEEDED TO SIMPLIFY THEIR ANALYSIS Mosca S., Guerriero E., Rotatori M.

2 The analysis of PCDD/Fs, PCBs and other related compounds requires complex analytical procedures using highly sensitive and selective instrumentation to meet very stringent data quality objectives.

3 At present, methods for analyses of dioxins and dioxin-like PCBs are expensive and slow. Therefore low-cost and fast methods have to be developed allowing to analyse in routinely manner a great number of samples and to provide quick, cheap, and reliable results on the presence of those compounds in the environment, feed and food

4 To speed up the time for analysis is important to many of today s GC analysts as they look for ways to improve sample throughput, without sacrificing the quality of the analysis. Benefits of increasing sample throughput include: Decreased costs: Less people and/or instruments are required to do the same amount of work. Increased profit: More samples can be processed in the same amount of time; Customers may be willing to pay more to get their results faster (surcharge for quick turnaround)

5 SCHEME OF ANALYSIS SAMPLING Chromatography column I Mixed column with differently treated silica CLEAN-UP EXTRACTION Chromatography column II Aluminium oxide B Super I AND FRACTIONATION PCBs fraction PCDD/Fs fraction HRGC/HRMS analysis HRGC/HRMS analysis ANALYSIS

6 SCHEME OF ANALYSIS SAMPLING Chromatography column I Mixed column with differently treated silica CLEAN-UP EXTRACTION Chromatography column II Aluminium oxide B Super I AND FRACTIONATION PCBs fraction HRGC/HRMS analysis PCDD/Fs fraction HRGC/HRMS analysis ANALYSIS

7 CNR-IIA SAMPLING CAMPAIGNS Industrial emission sampling Power plants Iron sintering ore plants Refineryies Medical waste incinerators Other plants Ambient air sampling

8 Sources of PCDD/Fs and PCBs in air - EU25 (5kg TEQ/year) Incinerators are no longer the main producers of dioxins due to regulatory restrictions and the subsequent compulsory technological evolution of plants (4.000 kg/year) From: European Commission. Identification, assessment and prioritisation of EU measures to reduce releases of unintentionally produced/released POPs. Study for implementation of the Regulation (CE) 850/2004 on Persistent Organic Pollutants (POPs) - June 2006

9 IRON ORE SINTERING PLANT - Trieste ng I-TEQ/Nm3 2005: Precautionary seizure from Law Court Company required to be within 0.4 ng I-TEQ/Nm 3 of PCCD/F Evaluation of influence of different charge typologies and additives on PCDD/Fs amount production and on congeneres profiles E. Guerriero et al., Environ. Eng. Sci. 26(1) (2009) ,00 1,50 Studies about mechanisms of dioxin reduction 1,00 0,50 E. Guerriero et al. J. Hazard. Mater. 172 (2009) ,00

10 POPs processes in the atmosphere A simultaneous monitoring of all affected environmental compounds is of great importance

11 AMBIENT AIR SAMPLING PCDD/Fs PCBs PAHs HCB Sintering plant

12 % I-TEQ Ambient air VS emission sampling % I-TEQ 60 Via Pitacco Ambient air sampling media % febbraio media % luglio The congener pattern in ambient air samples is similar to the pattern in a stack emission sample Flue gas stack emission emissioni forno di agglomerazione media % febbraio media % luglio

13 AMBIENT AIR REFERENCE VALUES European Directive 2004/107/CE (Italian Decree 152/2007) PAHs 1 ng/m 3 of B[a]P Air quality guidelines for Europe - WHO Regional Publications, 2000 PCDD/Fs PCBs 100 fg/nm fg/m 3 indicate local sources to be identified and checked 3 pg/m 3 in non-industrial area 3000 pg/m 3 in industrial/urban area Average values Decision guidance document UNEP, 1996 HCB 300 pg/m 3

14 AMBIENT AIR STANDARD METHODS In Europe. ISO PAHs (2000) ISO PCDD/Fs and PCBs (2006) EN B[a]pyrene (2006) VDI 3498 PCDD/Fs (2008) ISO Sampling strategy for PCDD/Fs, PCBs and PAHs (2007) Common aspects: - Flow rate (15 m 3 /h) - Sampling time (24h) - Sampling system (High volume sampler equipped with a quartz fiber filter followed by an adsorbent)

15 In the U.S. AMBIENT AIR STANDARD METHODS EPA Compendium Methods TO-4A PCBs and pesticides in ambient air (1999) TO-9A PCDD/Fs in ambient air (1999) TO-13A PAHs in ambient air (1999) Common aspects: -Sampling system (High volume sampler equipped with a quartz fiber filter followed by an adsorbent) - Flow rate: 225 l/min (total sampled volume = 300 m 3 ) -Sampling time: 24h -

16 There is a lack of a standard method for simultaneous sampling of micro-organic pollutants (PAHs, PCDD/Fs and dl-pcbs). introduction of a single sampling method with increased sampling time, from 1 to 7 days, to enrich the samples and to determine different compounds simultaneously. Money saving: The method is less expensive than 24 h sampling, requires fewer samples to be treated and it permits weekly or monthly concentration trends to be obtained. Time saving: Finally, different classes of compounds can be analyzed simultaneously from only one sample.

17

18 SCHEME OF ANALYSIS SAMPLING Chromatography column I Mixed column with differently treated silica CLEAN-UP EXTRACTION Chromatography column II Aluminium oxide B Super I AND FRACTIONATION PCBs fraction PCDD/Fs fraction HRGC/HRMS analysis HRGC/HRMS analysis ANALYSIS

19 SCHEME OF ANALYSIS SAMPLING Chromatography column I Mixed column with differently treated silica CLEAN-UP EXTRACTION Chromatography column II Aluminium oxide B Super I AND FRACTIONATION PCBs fraction PCDD/Fs fraction HRGC/HRMS analysis HRGC/HRMS analysis ANALYSIS

20 AUTOMATED CLEAN-UP SYSTEM PrepLinc Platform Automated Sample Preparation System (J2 Scientific) A combination of: - GPC column (BioBead SX-3) - concentration module - SPE module - autosampler Mosca etal Organohalogen Compd 70 (2008) 501; Rossetti etal. OrganohalogenCompd 71 (2009) 2278

21 SPE column sample PCBs PCDD/F Concentration chamber GPC column AUTOMATED CLEAN-UP SYSTEM PrepLinc Platform Automated Sample Preparation System

22 GEL PERMEATION CHROMATOGRAPHY GPC is a highly effective cleanup method for removing high molecular weight interferences (i.e. lipids, polymers, proteins, natural resins, and cellular components) from sample extracts. This technique is ideal for post-extraction clean-up of pesticide residues, semi-volatiles, PAHs, PCBs, mycotoxins and antibiotic residues from animal tissue, fatty foods, plant tissue, soil, sediment, sludge and wastewater. Can GPC be suitable as a clean-up method of PCDD/Fs from environmental samples 22

23 Manual VS Automated Clean-up Total: 215 Ambient air 7% Incinerat ors 26% Kiln f or t he product ion of aluminium 1% Ref inery ( boilers) 2% Kiln f or t he product ion of clay expanded 13% RDF incinerator 19% Tyre incinerator 40% Medical waste incinerator 11% Cement plant 19% Pharmaceutical incinerator 7% Biomass incinerator 14% MSW incinerator 9% Sint ering plant 14% Cement plant ( co- burning) 18%

24 Manual VS Automated Clean-up 13 C CONGENER MANUAL CLEAN-UP AUTOMATED CLEAN-UP 2,3,7,8-TCDD 88 ± 4 80 ± 6 1,2,3,7,8-PeCDD 90 ± 3 81 ± 5 1,2,3,4,7,8-HxCDD 99 ± 3 85 ± 7 1,2,3,6,7,8-HxCDD 95 ± 3 85 ± 8 1,2,3,4,6,7,8-HpCDD 87 ± 6 70 ± 5 OCDD 67 ± 9 58 ± 11 2,3,7,8-TCDF 88 ± 6 75 ± 8 2,3,4,7,8-PeCDF 86 ± 4 70 ± 6 1,2,3,4,7,8-HxCDF 98 ± 3 91 ± 5 1,2,3,6,7,8-HxCDF 93 ± 4 91 ± 6 2,3,4,6,7,8-HxCDF 100 ± 3 90 ± 6 1,2,3,4,6,7,8-HpCDF 93 ± 6 71 ± 8 OCDF 68 ± 9 62 ± 9 mean (n=24) recoveries of EN-1948 ES in sintering plant samples OCDF 1,2,3,4,6,7,8-HpCDF 2,3,4,6,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,4,7,8-HxCDF 2,3,4,7,8-PeCDF 2,3,7,8-TCDF OCDD 1,2,3,4,6,7,8-HpCDD 1,2,3,6,7,8-HxCDD 1,2,3,4,7,8-HxCDD 1,2,3,7,8-PeCDD 2,3,7,8-TCDD AUTOMATED CLEAN-UP MANUAL CLEAN-UP

25 % Recovery AVERAGE AUTOMATED CLEAN-UP RECOVERIES dl-pcbs PCDD/Fs It avoids the double analysis of dl- PCBs both in PCBs and in PCDD/Fs fraction: it means less standard solution to use and just two chromatographic runs

26 ADVANTAGES of the GPC/alumina automated purification system (1/2) Fast: in just over 1h it fully processes the sample from the extraction to the GC injection. The manual procedure, however, requires about 6h tomake the same process Time-saving: the automated system may work at night, standalone and it can processes up to 27 samples Money-saving: the GPC column is the same for hundreds of samples and the alumina microcolumn is one for each sample, whereas in the manual clean-up the operator prepares the adsorbents and then packs the column, one for each sample.

27 ADVANTAGES of the GPC/alumina automated purification system (2/2) Safer: the automated evaporation step is on-line: this allows a minor exposure of the operator to toxic solvents and is never exposed to chemical risk from agents like silica dust, acidic or AgNO 3 silica Green: it achieves the separation with a lower consumption of solvents (only DCM and Hex) Non-distructive : it is possible to analyze several classes of compounds within the considered mass range

28 SCHEME OF ANALYSIS SAMPLING Chromatography column I Mixed column with differently treated silica CLEAN-UP EXTRACTION Chromatography column II Aluminium oxide B Super I AND FRACTIONATION PCBs fraction PCDD/Fs fraction HRGC/HRMS analysis HRGC/HRMS analysis ANALYSIS

29 SCHEME OF ANALYSIS SAMPLING Chromatography column I Mixed column with differently treated silica CLEAN-UP EXTRACTION Chromatography column II Aluminium oxide B Super I AND FRACTIONATION PCBs fraction PCDD/Fs fraction HRGC/HRMS analysis HRGC/HRMS analysis ANALYSIS

30 Our goal: Separate and detect PCDD/Fs in the shortest amount of time possible HOW TO ACHIEVE OUR GOAL? Use different columns stationary phase type stationary phase thickness column length Use different temperature (or pressure) programs for the column Use different carrier gas (inert gas) Helium Hydrogen

31 ANALYTICAL INSTRUMENTATION GC/MS Thermo ITQ Thermo TSQ Quantum Autospec Ultima We are comparing the performances of LowRes MS (Ion Trap and Triple Quadrupole) vs HiRes MS in POPs analysis in different matrices

32 HRMS vs MS/MS: selectivity Precursor ion: [M] +, [M+2] + and [M+4] + (Resolution > 8200) CID (Precursor ion) (Product Ion) Product ions: [M-CO 35 Cl] +, [M+2-CO 35 Cl] +, [M+2-CO 37 Cl] +, [M+4-CO 37 Cl] +

33 Low Resolution Mass Spectrometer new method for the trace-level screening of PCDD/Fs, following the analytical strategy of U.S. EPA Method 1613 using TSQ Quantum XLS triple quadrupole gas chromatography tandem mass spectrometry (GC/MS/MS) instrument Using highly selective precursor ion selection and high-precision hyperbolic quadrupole technology available with the TSQ Quantum XLS, superior and uniform selectivity for screening for PCDD/Fs and PCBs at imposed MRLs in complex matrices is possible.

34 CONCLUSIONS In order to simplify POPs analysis, we suggest: SAMPLING Ambient air: simultaneous sampling, longer sampling time Industrial emission: Long-term sampling CLEAN-UP Automated clean-up (i.e. GPC+SPE based system) ANALYSIS Use of LowRes MS Use of a versatile GC column

35 THANK YOU FOR YOUR ATTENTION

Determination of PCDD/Fs in Environmental Samples using Accelerated Solvent Extraction (ASE) and GC-MS/MS

Determination of PCDD/Fs in Environmental Samples using Accelerated Solvent Extraction (ASE) and GC-MS/MS Determination of PCDD/Fs in Environmental Samples using Accelerated Solvent Extraction (ASE) and Paul Silcock, 1 David Gardner, 2 John Fardon, 2 Steve Moss 2 and Inge de Dobbeleer 1 1 Thermo Scientific

More information

Application Note. Abstract. Authors. Food Safety

Application Note. Abstract. Authors. Food Safety Determination of Dioxin-Like and Non-Dioxin-Like Polychlorinated Biphenyl Congeners in Foodstuffs and Animal Feed Using the Agilent 7000 Triple Quadrupole GC/MS System Application Note Food Safety Authors

More information

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants Version 2004-01 / August 2004 (HGRS-JW-04-25s) HGRS-CTS/MT J. Waltisberg SUMMARY ( ) shall not

More information

Thermo Scientific TSQ Quantum XLS Triple Quadrupole GC-MS/MS

Thermo Scientific TSQ Quantum XLS Triple Quadrupole GC-MS/MS c h r o m a t o g r a p h y Thermo Scientific TSQ Quantum XLS Triple Quadrupole GC-MS/MS The Next Evolution in GC Triple Quadrupoles Higher Sample Throughput Higher Productivity Detection Limits Beyond

More information

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup Application Note 25570306 Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup Keywords Gel Permeation Chromatography GPC AutoPrep 2000 Pesticides RapidVap N2 System

More information

LC-MS/MS, the new reference method for mycotoxin analysis

LC-MS/MS, the new reference method for mycotoxin analysis LC-MS/MS, the new reference method for mycotoxin analysis What is necessary for the implementation of the multi-residue mycotoxin method in an analytical laboratory? Azel Swemmer azel@fdalab.co.za AFMA

More information

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Automation of Solid Phase Extraction and Column Chromatographic Cleanup Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for

More information

How To Test For Contamination In Large Volume Water

How To Test For Contamination In Large Volume Water Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed

More information

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific Pesticide residue analysis: New Trends Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific Why pesticide analysis? Extensively used in agriculture to control

More information

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS-1603. No. SSI-GCMS-1603. Shilpi Chopra, Ph.D.

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS-1603. No. SSI-GCMS-1603. Shilpi Chopra, Ph.D. Gas Chromatograph Mass Spectrometer No. GCMS-1603 Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS Shilpi Chopra, Ph.D. Introduction Organophosphorus (OP) pesticides are a class

More information

Which analytical tools/instruments/techniques are used for POPs. A general walk through the analysis

Which analytical tools/instruments/techniques are used for POPs. A general walk through the analysis Which analytical tools/instruments/techniques are used for POPs A general walk through the analysis Kay Kelterer Eurofins GfA Lab Service GmbH Großmoorbogen 25, 21079 Hamburg, Germany 23.04.2015 Miljøgifter

More information

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample

More information

HORIZONTAL concerning the layout, editorial and technical content, this document needs revising. In order to harmonize all documents within

HORIZONTAL concerning the layout, editorial and technical content, this document needs revising. In order to harmonize all documents within Template for s and secretariat Date: 006-06-30 Document: CEN/BT/TF 151/TG 4 N0013 Horizontal 4.7 BFR Author s: ALL; Replies: TG 4 1 (3) 4 5 (6) (7) on each submitted NL ge This document is poorly attuned

More information

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex

More information

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10

More information

6. ANALYTICAL METHODS

6. ANALYTICAL METHODS 45 6.1 BIOLOGICAL MATERIALS No methods were located that are routinely used for the detection of BCEE in biological materials. Norpoth et al. (1986) reported a method for measuring thiodiglycolic acid

More information

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet TargetQuan 3 Software Leading the way in regulatory POPs quantification Bullet Bullet Bullet Leading the way in regulatory POPs quantification Analyse Samples Open Sequence Process Sequence Analyse Samples

More information

NUVISAN Pharma Services

NUVISAN Pharma Services NUVISAN Pharma Services CESI MS Now available! 1st CRO in Europe! At the highest levels of quality. LABORATORY SERVICES Equipment update STATE OF THE ART AT NUVISAN CESI MS Now available! 1st CRO in Europe!

More information

Advance Draft* December 2004

Advance Draft* December 2004 Advance Draft* Guidelines on best available techniques and provisional guidance on best environmental practices relevant to Article 5 and Annex C of the Stockholm Convention on Persistent Organic Pollutants

More information

European Union Reference Laboratory for Dioxins and PCBs in Feed and Food

European Union Reference Laboratory for Dioxins and PCBs in Feed and Food for Dioxins and s in Feed and Food Chemisches und Veterinäruntersuchungsamt Freiburg PO Box 46 D-793 Freiburg Germany CEN Ring Trial - Animal Feed Ring trial on determination of PCDD/Fs and s in animal

More information

Our staff... Our power

Our staff... Our power ABOUT US... Centro Analisi Biochimiche, thanks to its multiyear experience and its staff s competence, succeeded to achieve during these years an increasing prestige in analitical and advice services,

More information

Advancing the State of Analytical Science. for air, water and soil analysis. and beyond

Advancing the State of Analytical Science. for air, water and soil analysis. and beyond Advancing the State of Analytical Science for air, water and soil analysis and beyond Full Spectrum of Services SEMICONDUCTOR SECTOR ENVIRONMENTAL INDUSTRY HIGH TECHNOLOGY R&D Process Analysis Substrate,

More information

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)

More information

LC-MS/MS for Chromatographers

LC-MS/MS for Chromatographers LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS, with an emphasis on the analysis of drugs in biological matrices LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS,

More information

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322. i.chianella.1998@cranfield.ac.

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322. i.chianella.1998@cranfield.ac. SPE and HPLC Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322 i.chianella.1998@cranfield.ac.uk Solid-Phase Extraction- SPE Simple, fast and efficient sample preparation

More information

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report PRODUCT BULLETIN Cliquid ChemoView 3.0 Software for Routine Screening and Quantitation Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report KEY FEATURES Secure user login that

More information

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz Toxichem Krimtech 211;78(Special Issue):324 Online extraction LC-MS n method for the detection of drugs in urine, serum and heparinized plasma Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische

More information

Background Information

Background Information 1 Gas Chromatography/Mass Spectroscopy (GC/MS/MS) Background Information Instructions for the Operation of the Varian CP-3800 Gas Chromatograph/ Varian Saturn 2200 GC/MS/MS See the Cary Eclipse Software

More information

Bioremediation of contaminated soil. Dr. Piyapawn Somsamak Department of Environmental Science Kasetsart University

Bioremediation of contaminated soil. Dr. Piyapawn Somsamak Department of Environmental Science Kasetsart University Bioremediation of contaminated soil Dr. Piyapawn Somsamak Department of Environmental Science Kasetsart University Outline Process description In situ vs ex situ bioremediation Intrinsic biodegradation

More information

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation

More information

Determination of Polycyclic Aromatic Hydrocarbons (PAH) in Food with GC-MS/MS

Determination of Polycyclic Aromatic Hydrocarbons (PAH) in Food with GC-MS/MS Determination of Polycyclic Aromatic Hydrocarbons (PAH) in Food with GC-MS/MS Thorsten Bernsmann, Peter Fürst Chemical and Veterinary Analytical Institute Münsterland-Emscher-Lippe Joseph-König-Str. 40,

More information

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay PO-CON1484E Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching ASMS 014 TP85 David R. Baker 1, John Warrander 1, Neil Loftus 1, Simon Hird

More information

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system

More information

WATERS QUANTITATIVE ANALYSIS solutions

WATERS QUANTITATIVE ANALYSIS solutions More sensitivity. More speed. What more can you ask for in a complete quantitative analysis solution? WATERS QUANTITATIVE ANALYSIS solutions THE CHALLENGE OF QUANTITATIVE ANALYSIS Tandem mass spectrometry,

More information

METHOD SUMMARY & DATA QUALITY OBJECTIVES

METHOD SUMMARY & DATA QUALITY OBJECTIVES METHOD SUMMARY & DATA QUALITY OBJECTIVES TestAmerica West Sacramento Method 1613B: Polychlorinated Dibenzo-p-dioxins (PCDDs) and Polychlorinated Dibenzofurans (PCDFs) by High Resolution Gas Chromatography/High

More information

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS Bruker ToxScreener TM A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS ToxScreener - Get the Complete Picture Forensic laboratories are frequently required

More information

R E P O R T. Swan Hills Waste Treatment Center. Long-Term Follow-up Health Assessment Program 1997-2002 Health Surveillance

R E P O R T. Swan Hills Waste Treatment Center. Long-Term Follow-up Health Assessment Program 1997-2002 Health Surveillance R E P O R T Swan Hills Waste Treatment Center Long-Term Follow-up Health Assessment Program 1997-2002 Health Surveillance JUNE 2004 Swan Hills Waste Treatment Center Long-Term Follow-up Health Assessment

More information

White Paper: EPRI s Preliminary Evaluation of the Available HAPs ICR Data Paul Chu, Naomi Goodman Amended January 7, 2011

White Paper: EPRI s Preliminary Evaluation of the Available HAPs ICR Data Paul Chu, Naomi Goodman Amended January 7, 2011 White Paper: EPRI s Preliminary Evaluation of the Available HAPs ICR Data Paul Chu, Naomi Goodman Amended January 7, 2011 1. Background In December 2009, the U.S. Environmental Protection Agency (EPA)

More information

How To Run A Power Plant In Celje

How To Run A Power Plant In Celje VRANSKO, May 2009 Waste Management Strategy Waste management strategy in accordance with European directive 91/156/EEC: 1. Reduction at source 2. Reuse 3. Recycle 4. Energy recovery 5.Disposal Celje Regional

More information

Costs of air pollution from European industrial facilities 2008 2012 an updated assessment

Costs of air pollution from European industrial facilities 2008 2012 an updated assessment Costs of air pollution from European industrial facilities 2008 2012 an updated assessment Summary In 2012, air pollution from European industrial facilities cost at least EUR 59 billion (and up to EUR

More information

SCION SQ Series GC-MS

SCION SQ Series GC-MS SCION SQ Series GC-MS The Gas Chromatographers Detector SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative

More information

Data and Trends. Environmental protection and Safety

Data and Trends. Environmental protection and Safety Data and Trends Environmental protection and Safety 2006 EMS-GRIVORY Performance Polymers EMS-GRIVORY Extrusion Polymers EMS-GRILTECH EMS-PRIMID EMS-PATVAG EMS-SERVICES Data and Trends 2006 Protection

More information

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer Hideki Nagano*, Kunio Miyazawa**, Yoshinori Yomura***, Toshihiko Iwasaki****, Takashi Yokoyama***** and

More information

IT3 01 Conference, Philadelphia, PA, May 14-18, 2001

IT3 01 Conference, Philadelphia, PA, May 14-18, 2001 IT3 01 Conference, Philadelphia, PA, May 14-18, 2001 BAGHOUSE OPTIMIZATION AT A MEDICAL WASTE INCINERATOR R. D. Montgomery Phoenix Services, Inc. John Kumm EA Engineering, Science, and Technology C. P.

More information

WASTE INCINERATION IN CEMENT KILNS A local and global problem

WASTE INCINERATION IN CEMENT KILNS A local and global problem WASTE INCINERATION IN CEMENT KILNS A local and global problem Mariel Vilella Casaus Zero Waste Europe/GAIA Barletta, 8th November 2014 GAIA: INTERNATIONAL ALLIANCE FOUNDED IN 2000 TO END ALL FORMS OF WASTE

More information

Revealing the costs of air pollution from industrial facilities in Europe a summary for policymakers

Revealing the costs of air pollution from industrial facilities in Europe a summary for policymakers Revealing the costs of air pollution from industrial facilities in Europe a summary for policymakers A new European Environment Agency (EEA report, Revealing the costs of air pollution from industrial

More information

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES AGILENT ENHANCED MATRIX REMOVAL LIPID ARE LIPIDS WEIGHING YOUR SAMPLES DOWN? Interference from lipids is a problem for labs measuring

More information

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

HRMS in Clinical Research: from Targeted Quantification to Metabolomics A sponsored whitepaper. HRMS in Clinical Research: from Targeted Quantification to Metabolomics By: Bertrand Rochat Ph. D., Research Project Leader, Faculté de Biologie et de Médecine of the Centre Hospitalier

More information

GOED VOLUNTARY MONOGRAPH (v. 4)

GOED VOLUNTARY MONOGRAPH (v. 4) GOED VOLUNTARY MONOGRAPH (v. 4) Omega-3 EPA Omega-3 DHA Omega-3 EPA & DHA DEFINITION Omega-3 fatty acids, EPA and DHA, consist of the all cis forms of 5, 8, 11, 14, 17-eicosapentaenoic acid and 4, 7, 10,

More information

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS AxION iqt GC/MS/MS INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE IDENTIFY WHAT YOU RE LOOKING FOR (AND EVEN WHAT YOU RE NOT) The GC/MS/MS Solution for the Work You Do The ideal solution for industrial,

More information

Pesticide Analysis by Mass Spectrometry

Pesticide Analysis by Mass Spectrometry Pesticide Analysis by Mass Spectrometry Purpose: The purpose of this assignment is to introduce concepts of mass spectrometry (MS) as they pertain to the qualitative and quantitative analysis of organochlorine

More information

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Application Note AN844 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Page 1 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Introduction Catecholamines

More information

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software Abstract Presented here is a case study of a walk-up liquid chromatography

More information

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Application Note 1097 Liu Qian, Zheng Hongguo and

More information

Accepted 26 May 2006 Available online 17 January 2007

Accepted 26 May 2006 Available online 17 January 2007 Chemosphere 67 (27) 1822 183 www.elsevier.com/locate/chemosphere A study on PCB, PCDD/PCDF industrial contamination in a mixed urban-agricultural area significantly affecting the food chain and the human

More information

ANNEX 1 of Horizontal desk study 27 Brominated Flame Retardents

ANNEX 1 of Horizontal desk study 27 Brominated Flame Retardents ANNEX 1 of Horizontal desk study 27 Brominated Flame Retardents PBDEs in sludge, waste, soil and sediment. This paper has been written for the Horizontal Standards on Organic Micro-pollutants for Implementation

More information

PHARMACEUTICAL AND CHEMICAL WASTE MANAGEMENT

PHARMACEUTICAL AND CHEMICAL WASTE MANAGEMENT Medicines and Medical Devices Agency of Serbia PHARMACEUTICAL AND CHEMICAL WASTE MANAGEMENT Ivana Bozic, MSc Health, Safety and Environment ISWA Beacon Conference, Novi Sad, 08 10 December 2010 458, Vojvode

More information

Analyzing Small Molecules by EI and GC-MS. July 2014

Analyzing Small Molecules by EI and GC-MS. July 2014 Analyzing Small Molecules by EI and GC-MS July 2014 Samples Appropriate for GC-MS Volatile and semi-volatile organic compounds Rule of thumb,

More information

Waste Incineration Plants

Waste Incineration Plants Waste Incineration Plants Modern Technology for a better Environmental Welcome at Hafner! We Manufacture Systems for Energy Recovery from Wastes and Biomass as well as for Treatment of Hazardous Wastes.

More information

Introduction to Proteomics 1.0

Introduction to Proteomics 1.0 Introduction to Proteomics 1.0 CMSP Workshop Tim Griffin Associate Professor, BMBB Faculty Director, CMSP Objectives Why are we here? For participants: Learn basics of MS-based proteomics Learn what s

More information

AUTOMATED SAMPLE PREP CAPITAL EXPENDITURE JUSTIFICATION REPORT

AUTOMATED SAMPLE PREP CAPITAL EXPENDITURE JUSTIFICATION REPORT AUTOMATED SAMPLE PREP CAPITAL EXPENDITURE JUSTIFICATION REPORT Purchase of Solid Phase Extraction Equipment EXECUTIVE SUMMARY Any Environmental Lab Commercial Laboratory Operation requests funds in the

More information

The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies

The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies INEF Penn State Conference 2013 Albert Robbat, Jr. and Patrick Antle Tufts University, Chemistry

More information

How To Analyze Pesticide Levels In Lemon Oil

How To Analyze Pesticide Levels In Lemon Oil AppNote 9/2006 Target GC-MS Analysis using Accelerated Column Heating and Interactive Deconvolution Software Albert Robbat Tufts University, Chemistry Department, Medford, MA 02155, USA Andreas Hoffmann

More information

MILESTONE START D. Microwave Digestion System

MILESTONE START D. Microwave Digestion System MILESTONE H E L P I N G C H E M I S T S START D Microwave Digestion System The unique START D Milestone has been active for two decades in the field of microwave sample preparation and, with more than

More information

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Gas Chromatography Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Samples in 10mL sealed glass vials were placed in the MPS-2

More information

PCBs DETERMINATION IN TRANSFORMER OIL BY SPE AND GAS CHROMATOGRAPHY ANALYSIS

PCBs DETERMINATION IN TRANSFORMER OIL BY SPE AND GAS CHROMATOGRAPHY ANALYSIS PCBs DETERMINATION IN TRANSFORMER OIL BY SPE AND GAS CHROMATOGRAPHY ANALYSIS Bogdevich O.P. *, Cadocinicov O.P. * Institute of Geophysics and Geology, Laboratory of Geochemistry GEOLAB Academiei str. 3,

More information

Sludge Treatment Facility Stack Gas Monitoring Report February 2016

Sludge Treatment Facility Stack Gas Monitoring Report February 2016 I. INTRODUCTION This Monthly Report aims to provide a summary of environmental performance of the Sludge Treatment Facility (STF) over the monitoring period, which includes the air emission data collected

More information

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies Supelco Innovation Seminars November 11 th, 2010 Atlanta, GA Enhancing Utility and Throughput of SPME using Advanced Automation Strategies Presented by Tom Tobien, Ph.D. Analytical Chemist, LEAP Technologies,

More information

ANNUAL PERFORMANCE REPORT 2012. This report fulfils the requirements of Article 12(2) of the Waste Incineration Directive regarding the:

ANNUAL PERFORMANCE REPORT 2012. This report fulfils the requirements of Article 12(2) of the Waste Incineration Directive regarding the: ANNUAL PERFORMANCE REPORT 2012 Sheffield Energy Recovery Facility PPC Permit: BM4082 1. Introduction. This report fulfils the requirements of Article 12(2) of the Waste Incineration Directive regarding

More information

Thermal & Biogas Production In Egypt. By Prof. Dr. Ahmed Abd El-Ati Ahmed Egypt - GBEP Focal Point

Thermal & Biogas Production In Egypt. By Prof. Dr. Ahmed Abd El-Ati Ahmed Egypt - GBEP Focal Point Thermal & Biogas Production In Egypt By Prof. Dr. Ahmed Abd El-Ati Ahmed Egypt - GBEP Focal Point Some Related Socioeconomic indicators : The total land area is 1 Million Km 2. 97 % of the total area is

More information

Examination syllabuses for Manual Stack emissions monitoring. Environment Agency Version 9 January 2015

Examination syllabuses for Manual Stack emissions monitoring. Environment Agency Version 9 January 2015 Examination syllabuses for Manual Stack emissions monitoring Environment Agency Version 9 January 2015 Record of amendments Version Date Section Amendment number 6 August 09 Level 1 Updated Level 1 syllabus

More information

ULUDAĞ UNIVERSITY INSTITUTE OF SCIENCE ENVIRONMENTAL ENGINEERING 2013-2014 ACADEMIC YEAR INSTITUTE REQUIRED COURSES

ULUDAĞ UNIVERSITY INSTITUTE OF SCIENCE ENVIRONMENTAL ENGINEERING 2013-2014 ACADEMIC YEAR INSTITUTE REQUIRED COURSES GRADUATE PROGRAM ULUDAĞ UNIVERSITY ENVIRONMENTAL ENGINEERING 2013-2014 ACADEMIC YEAR INSTITUTE REQUIRED COURSES DOCTORAL PROGRAM OF Code Course Title T U L Credit ECTS Prerequisite Code Course Title T

More information

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Lecture Chromo-3: Gas Chromatography CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Outline Introduction Instrument overview Carrier gas Sample

More information

Department of Environmental Engineering

Department of Environmental Engineering Department of Environmental Engineering Master of Engineering Program in Environmental Engineering (International Program) M.Eng. (Environmental Engineering) Plan A Option 1: (1) Major courses: minimum

More information

AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements?

AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements? AutoSpec Premier Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements? Looking for sensitivity, selectivity and dynamic range? The AutoSpec Premier is the latest

More information

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples

More information

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water Sjaak de Koning 1, Mark van Lieshout 2, Hans-Gerd Janssen 2 and Wil van Egmond 1 1 ATAS, De Run 4334, PO Box

More information

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from uman Plasma Krishna Rao Dara, Dr. Tushar N. Mehta, Asia Pacific Center of Excellence, Thermo Fisher Scientific, Ahmedabad, India Application

More information

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality

More information

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays Scheduled MRM HR Workflow on the TripleTOF Systems Jenny Albanese, Christie Hunter AB SCIEX, USA Targeted quantitative

More information

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward Chemical Analysis Natural Gas Analyzer A Family of optimized GC Solutions think forward Gas Chromatography Bruker Natural Gas Analyzers Natural gas is bought and sold as a bulk commodity with price based

More information

Paper Chromatography: Separation and Identification of Five Metal Cations

Paper Chromatography: Separation and Identification of Five Metal Cations Paper Chromatography: Separation and Identification of Five Metal Cations Objectives Known and unknown solutions of the metal ions Ag +, Fe 3+, Co 2+, Cu 2+ and Hg 2+ will be analyzed using paper chromatography.

More information

Multi-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible

Multi-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible Multi-Shot Pyrolyzer EGA/PY-3030D Flexible Versatile Reproducible Why Evolved Gas Analysis? Why Pyrolysis? Today, analytical pyrolysis encompasses much more than simple flash pyrolysis of polymeric materials.

More information

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS Application Note: 446 Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS Jonathan McNally and Michael Belford, Thermo Fisher Scientific, San Jose, CA James Kapron, Thermo Fisher Scientific,

More information

Official Journal of the European Communities

Official Journal of the European Communities L 332/91 DIRECTIVE 2000/76/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 December 2000 on the incineration of waste THE EUROPEAN PARLIAMENT AND THE COUNCIL OF THE EUROPEAN UNION, waste, and 0,2

More information

Remediation of VOC Contaminated Groundwater

Remediation of VOC Contaminated Groundwater Remediation of VOC Contaminated Groundwater Background Contaminated groundwater has become an ever-increasing problem in the United States and around the world. Treatment and disposal of waste is a serious

More information

Procedia Environmental Science, Engineering and Management

Procedia Environmental Science, Engineering and Management Procedia Environmental Science, Engineering and Management http://www.procedia-esem.eu Procedia Environmental Science, Engineering and Management 1 (2014) (1) 59-63 18th International Trade Fair of Material

More information

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference Abstract The advantages of mass spectrometry (MS) in combination with gas

More information

NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT

NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT AND ANALYSIS SEPTEMBER 2012, V 1.1 4878 RONSON CT STE K SAN DIEGO, CA 92111 858-565 - 4227 NANOCOMPOSIX.COM Note to the Reader: We at nanocomposix have published

More information

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE Solid Phase Extraction Products PAGE: 1 Introduction of Solid Phase Extraction (SPE) SPE has been used increasingly in chemical analysis and purification broadly, and become the most popular technology

More information

Healthcare Waste Management Training

Healthcare Waste Management Training WHO Regional Office for Europe Healthcare Waste Management Training Module 6 International & national regulations, guidelines, policies Content International principles for handling waste Kenya s guidelines

More information

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in

More information

GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs

GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs Kinet C, De Pauw E, Focant JF CART, Mass Spectrometry Laboratory, Chemistry Department, University of Liège, Allée de la Chimie 3,

More information

Developments and trends shaping the future for Waste-to- Energy technology suppliers

Developments and trends shaping the future for Waste-to- Energy technology suppliers Developments and trends shaping the future for Waste-to- Energy technology suppliers 21 st October 2015 Copenhagen, Denmark Edmund Fleck ESWET President 2 Contents 1. About ESWET 2. Introduction 3. Modern

More information

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening Application Note Forensics Author Erin Shonsey Director of Research Alabama Department of Forensic Science Abstract

More information