Inspection, Testing and Preventive Maintenance
|
|
|
- Blaise Sharp
- 10 years ago
- Views:
Transcription
1 Fire Protection Systems and Equipment Introduction HSB Professional Loss Control Two Crossroads Drive Bedminster, NJ The owners and operators of industrial plants, shopping centers, universities, hospitals, and similar large, complex facilities have a significant investment in fire protection systems and equipment. Fortunately, this hardware is seldom called upon to perform the job for which it was provided. However, when needed, it must perform flawlessly often to keep a small problem from becoming a disaster. Many plant engineers, risk managers and others responsible for facility operation do not adequately concern themselves with the inspection, testing and preventive maintenance (I,T & PM) of their fire protection systems and equipment. Downsizing has eliminated many of the people who had valuable experience and time available for this critical work, and it may now be performed poorly, if at all, by unqualified personnel. Insurance inspectors, who some facility operators expect to police this effort, are usually unable to spend the time necessary at every facility to make certain all of the fire protection systems and equipment are in top condition. The management of any facility is ultimately responsible for being aware of the requirements that apply to their particular systems, structures, occupancies and operations. This paper is provided as a planning tool to assist facility management in developing a comprehensive program of I,T & PM for fire protection systems and equipment. I,T & PM Requirements in the NFPA Standards Most of the NFPA standards contain recommendations for the type and frequency of I,T & PM activities. However, for the systems and equipment at any given facility, this information is probably scattered through a number of different standards, making it difficult to obtain an overview of all the work that needs to be accomplished or to evaluate alternative approaches. NFPA : Maintenance of Water-Based Fire Protection Systems is now included in the standards library. This very useful document pulls together the detailed I,T & PM recommendations in several existing standards, including those for fire pumps, private water supplies, standpipe and hose, and sprinkler systems of various kinds. It does not include
2 Page 2/14 suppression systems using gaseous and chemical agents, portable fire extinguishers, exit components, detection and alarm systems, in-plant fire apparatus, and other systems and equipment often included in the fire protection mix of a particular facility. The table in this paper contains an overview of NFPA recommendations for I,T & PM on the most frequently encountered fire protection systems and equipment as an aid for planning and scheduling these activities. It includes the recommendations from a total of 23 current NFPA standards. Note: The table is only a summary and the specific standards referenced should be consulted for critical details that were not included so that the document remained of manageable size. The various recommendations have been arranged, edited and, in some cases, interpreted to provide a useable planning tool. Most of the recommendations are located in the main body of the referenced standards; however a few are in appendices. The tabulation does not include acceptance testing or recommendations in many other NFPA standards related to specific occupancies, specific hazards or fire service equipment. Although reasonable effort was made to ensure the tabulation is accurate and complete for the standards listed, this is not guaranteed. Type and Frequency of I,T & PM Activities Taking a critical look at the I,T & PM needed for a particular facility, and at what intervals, is likely to be a challenging task. The frequency of these activities tends to be more controversial than their nature. Most would agree that a fire pump should be periodically tested to see whether it will start automatically, since this is an expensive and critical piece of equipment to let sit idle year after year and hope it will work if it is ever needed. But whether such a test should be performed every day, week, month, year or millennium is not as easily established. The recommendations contained in the NFPA standards obviously provide a very important reference point. However, these standards come from the consensus process in which many interests and experiences are represented, including those of property owners, insurers, public officials, emergency responders, suppliers of the systems and equipment, and servicing contractors. Many of the recommendations in the NFPA standards are based on a combination of tradition and anecdotal experience and are pretty much of a one size fits all variety without particularly recognizing variations in conditions at different facilities. This is not to say the recommendations contained in the NFPA standards are inappropriate, only that they are not tailored to a specific facility and do not usually have a rigorous statistical or probabilistic basis. Although the NFPA standards are widely accepted and referenced, local, state or Federal agencies with regulatory authority may have specific requirements that differ from the NFPA recommendations. Particular insurance carriers may also have different criteria, and manufacturer s recommendations or site conditions can influence activities or frequencies. Unless specific requirements of a regulatory agency or an insurance underwriter exist, facility specific I,T & PM criteria can be developed if they can be based on appropriate risk-based / reliability-centered techniques. Be advised,
3 Page 3/14 however, that such may be more easily wished than accomplished given the typical scarcity of useable supporting data. When this approach is taken, the consensus NFPA recommendations can still serve as a starting point or a content check for developing facility-specific guidelines based on more rigorous analysis. This type of analysis, by the way, should not always be viewed as simply a means of reducing the level of effort. In some cases, additional activities or increased performance frequencies may result from such an exercise. Who Performs and/or Witnesses the Work The table included with this paper contains an indication of who might typically best perform the various I,T & PM tasks (i.e. facility personnel or an outside contractor). This is something that is not included in the NFPA standards and is provided here simply for planning guidance, to be revised as appropriate for each specific facility or organization. Fire protection systems have some unique attributes, a lot having to do with code requirements and their unusual standby operating status. As a result, otherwise skilled and knowledgeable electricians, mechanics and other trade specialists may not have an appreciation of the peculiarities of fire protection systems, and many have little if any real working experience with them. Fire protection contractors have been used most often for servicing special hazard protection such as carbon dioxide and foam systems. Current downsizing and outsourcing trends encourage increased use of contractors, not so much for routine inspections, but for the more time consuming testing and preventive maintenance activities such as those required for fire pumps and detection systems. Who performs a particular task varies considerably from facility to facility, depending to some extent on the capabilities and labor practices of the organization involved. The size of a facility is a major factor influencing the use of outside contractors. Larger operations typically have available a bigger and more diversified internal labor pool. Even when facility personnel are available to do the work, a contractor may be used for efficiency and quality on jobs that are performed infrequently and involve complicated, seldom used procedures or special tools. Also, it is less likely that necessary work on fire protection systems will be postponed in favor of production-related demands when a contractor is budgeted and brought in for this specific purpose. When contractors are used, it is essential that the specific activities for which they are responsible be evaluated and clearly spelled out in the contract with the facility. In many instances, facility management abdicates real I,T & PM content evaluation and a low bid contractor provides an inadequate program. In some jurisdictions, a fire marshal or other official may have the authority to perform or witness certain inspections and tests on fire protection systems. Regulations requiring this are usually applied to occupancies that have a high public safety exposure, such as schools, hospitals, nursing homes, hotels and theaters. Fire service inspections are most likely to be associated with fire alarm systems, exits and other life safety features.
4 Page 4/14 Insurance carriers may want to be involved in certain inspection and testing activities, particularly those related to water supplies and sprinkler systems. Each insurer has their own criteria and a clear understanding should be reached as to their anticipated participation in and scheduling of these tasks, particularly when a new carrier enters the picture. Sometimes a specific contractual agreement between insured and insurer spells this out, but more often it is simply left to the prerogative of the insurer and may change with workload or other pressures on the availability of their field staff. In any case, facility management must be sure that I,T & PM work is performed in a correct and timely manner, regardless of regulatory or insurance involvement. Recommendations to Upgrade an I,T & PM Program What should be done to improve a program for the I,T & PM of facility fire protection systems and equipment? The following steps are recommended: Review the recognized NFPA standards to see what they recommend be provided for your facility. Develop site-specific criteria using the recommendations in the NFPA standards as a base, modified by any regulatory or insurance requirements and to the extent possible by sound risk/reliability analysis. Use facility personnel only for those activities that reasonably fit their experience and availability. Use local fire protection contractors to perform work that requires special experience or tools, but be sure that between in-house personnel and contractors, all elements of the program are covered. Provide oversight monitoring to ensure this critical work is performed correctly and in a timely manner following the guidelines developed. Summary There is no doubt that a well conceived I,T & PM program is essential for maintaining the functionality of fire protection systems and equipment. The NFPA standards provide a good benchmark for establishing such a program and the table contained in this paper contains an overview of these recommendations. It may be necessary to consider specific regulatory or insurance requirements as well. The type and frequencies of this work can be modified for facility-specific conditions, but this should only be done on the basis of a realistic risk/ reliability analysis and not merely to achieve temporary cost savings or personnel reductions. The use of outside contractors to perform selected testing and maintenance work is often a means to improve the quality and timeliness of the program. Ultimately, the facility management is responsible for establishing and monitoring the I,T & PM program to be certain that it ensures the functionality of fire protection systems and equipment. This important responsibility should not be neglected.
5 Page 5/14 Frequency, Type Activity and Who Performs FREQUENCY: Dy = Daily Wk = Weekly Mo = Monthly Qt = Quarterly Se = Semiannually An = Annually TYPE ACTIVITY: I = Inspection T = Testing PM = 2 50yr = Number of Years VLC = Varies with Local Conditions PERFORMED BY: F = Facility Personnel C = Contractor F/C = Facility or Contractor Water-Based Systems: NFPA Control Valves Position (sealed only) Wk I F Position (locked or electrically supervised) Mo I F Tamper Switches Tamper Switches Se T F Full Operation An T F Lubrication An PM F Fire Hydrants Condition An I F Flow, Operability and Drainage An T F Lubrication An PM F Fire Department Connections Condition and Accessibility Qt I F Monitor Nozzles Condition and Accessibility Se I F Flow and Operability An T F Lubrication An PM F Mainline Strainers Internal Component Servicing An PM F/C Check Valves Internal Component Servicing 5yr PM F/C Backflow Prevention Assemblies Isolation Valves (unsupervised) Wk I F Isolation Valves (electrically supervised) Mo I F Flow (forward / backward / design) An T C Internal Component Servicing VLC PM C
6 Page 6/14 Pressure Relief Valves Condition Qt I F Partial Flow An T F/C Full Flow 5yr T F/C Piping Systems - See NFPA 24 also. Leaks / Corrosion / Damage / Restraints (exposed outdoor) An I F Fire Flow and Friction Loss Analysis 5yr T C Yard Fire Hose Hose House and Equipment Qt I F Hose House An PM F Hose (hydrostatic) - See NFPA 1962 also. 5/3yr T C Standpipe and Hose Systems - See NFPA 14 also. Pressure Regulating Devices, Piping and Hose Connections Qt I F Water Flow and Supervisory Alarm Devices Qt T F Nozzles, Hose Storage Devices and Cabinets An I F Pressure Regulating Devices (partial flow) An T F/C Main Drain Hose (unrack / unreel) An PM F Hose Connections and Valves (lubricate) Hose (hydrostatic) - See NFPA 1962 also. 5/3yr T C Water Supply and Piping System (flow) 5yr T C Pressure Regulating Devices (full flow) Dry Piping Systems (hydrostatic) Fire Pumps - See NFPA 20 also. Pumps, Motors, Engines, Controllers, Batteries, Fuel Systems, Switches, Gauges, Lubricants, Coolant, Piping, Isolation Valves, Relief Valves and Pump House Wk I F Pump (automatic start and run) Wk T F Diesel Fuel System (operation) Battery Charging System) Mo I F Motor Isolation Switch and Main Circuit Breaker (exercise) Mo T F Batteries (specific gravity) Batteries (clean) Mo PM F Batteries (terminals) Qt I F Electrical Wiring Fuel Strainer, Water Supply Strainer and Crankcase Breather Qt PM F Engine Exhaust Insulation Se I F Motor (manual start) Se T F Engine Anti-freeze (condition) Safeties and Alarms
7 Page 7/14 Electrical Components (clean) Se PM F Pump (flow performance) An T C Circulation Relief Valve (closing) Low Suction Pressure Control Devices Automatic Transfer Switch Gauges, Alarm Sensors and Indicators Motor (voltage and current) Pump Room (environmental controls) Engine Exhaust (back pressure) Pumps, Motors, Engines, Mechanical Transmissions, Controllers and Other System Components (lubrication) An PM C Fuel Tank (water/sediment, vents/overflow, piping system) Engine Coolant (replace) Pressure Relief Valve (adjust) Combustion Air System (clean) Heat Exchanger (clean) Electrical Components (lubricate, trip circuit breakers, tighten connections) Circuit Breakers and Fuses 2yr PM C Water Tanks - See NFPA 22 also. Heating System and Water Temperature (unsupervised - during cold weather) Dy I F Heating System and Water Temperature (electrically supervised - during cold weather) Wk I F Water Level (unsupervised) Mo I F Air Pressure (unsupervised - pressure tanks) Water Temperature Alarms/Controls (during cold weather) Mo T F Water Level (electrically supervised) Qt I F Air Pressure (electrically supervised - pressure tanks) Tank, Structure and Surroundings (condition) Water Level Alarms Se T F Tank Contents (sediment flushing) Se PM F Tank Shell Exterior and Expansion Joints An I F Wood Tank Hoops and Grillage Heating System, Corrosion Protection and Vent Screens An PM F/C Drain Valve (cycling) Tank Interior (pressure tanks / tanks without corrosion protection) 3yr I F/C Tank Interior (tanks with corrosion protection) 5yr I F/C Level Indicators, Pressure Gauges and Check Valves Tank Exterior (shell painting) VLC PM C
8 Page 8/14 Sprinkler Systems - See NFPA 13 also. Heated Valve Enclosures (without temperature alarm - during cold weather) Dy I F Heated Valve Enclosures (with temperature alarm - during cold weather) Wk I F Gauges (dry pipe / preaction / deluge) Dry Pipe, Preaction, Deluge and Alarm Check Valves Mo I F Gauges (wet pipe / electrically supervised air pressure) Gauges (detection system air pressure) Mo T F Pressure Regulating Devices Qt I F Hydraulic Nameplate Alarm Devices Water Flow and Supervisory Alarms Qt T F/C Sprinkler Heads, Piping, Hangers and Seismic Braces An I F/C Building Freeze Protection Heated Valve Enclosures (low temperature alarms) Spare Sprinkler Head Supply and Wrenches Main Drain An T F/C Pressure Regulating Devices (partial flow) Sprinkler Heads (in commercial cooking equipment) An PM C Hose Connections (flow and alarm) 3yr T F/C Alarm Valves (interior components) 5yr T F/C Strainers, Filters and Orifices Gauges (calibrate or replace) Pressure Regulating Devices (full flow) Extra-high Temperature Sprinkler Heads Sprinkler Heads Over 75 Years Old Sprinkler Heads O-ring, Dry Systems 10yr T F/C Sprinkler Heads Fast-Response Type 20yr T F/C Sprinkler Heads All Types 50/10yr T F/C Sprinkler Heads Installed Before 1920 (replace) PM C Plastic Overspray Protection Bags (replace) VLC PM F Air Compressors and Dryers VLC PM F/C Special Sprinkler Systems (In addition to Sprinkler System items above as applicable.) Anti-freeze Systems Solution Freezing Point (before cold weather) An T F/C Dry Pipe Systems Priming Water Level Qt T F/C Air Pressure Alarms Quick Opening Devices Automatic Air Pressure Maintenance Devices An T F/C
9 Page 9/14 Dry Pipe Valve (trip and service) An PM C Low Point Drains (before cold weather) Dry Pipe Valve (trip and system flow) 3yr PM C Preaction Systems Priming Water Level (supervised system) Qt T F/C Low Air Pressure Alarms System Operation and Full Flow An T C Manual Releases Preaction Valve Service An PM C Low Point Drains (before cold weather) Preaction Valve Internal Inspection (when valve can be reset without removing faceplate) 5yr I C Deluge Systems Low Air Pressure Alarms Qt T F/C System Operation and Full Flow An T C Manual Releases An PM C Area Drainage Deluge Valve Servicing Low Point Drains (before cold weather) Operation and Full Flow (in situations where testing requires shutdown of operations) 3yr T C Deluge Valve Internal Inspection (when valve can be reset without removing faceplate) 5yr I C Water Spray Systems - See NFPA 15 also. Nozzle Condition Mo I F Area Drainage Qt I F Piping, Fittings, Supports and Hangers System Operation and Full Flow An T C Nozzle Discharge Patterns Manual Releases Deluge Valve Service An PM C Strainers (mainline and nozzle) Deluge Valve Service (when valve can be reset without removing faceplate) 5yr I F/C Strainers (mainline and nozzle), Filters, Orifices and Diaphragm Chambers Foam-Water Systems - See NFPA 16 also. Foam Concentrate Proportioning System Mo I F Spray Nozzle (location / position) Foam Concentrate Pump Mo PM F Overhead Piping, Fittings, Supports and Hangers Qt I F Area Drainage Foam Concentrate Strainer Qt PM F
10 Page 10/14 System Operation and Flow An T C Manual Actuation Backflow Preventer Sprinkler Heads (location / position) Foam Concentrate Sample Foam Concentrate System (strainers, pumps, vents) 5yr PM C Foam Concentrate Tank (drain / flush) 10yr PM C Foam Systems: See NFPA 11 and NFPA 11A also. Complete System Service (including foam concentrate quality and proportioning) An PM C Pipe (underground) 5yr I F Commercial Cooking Systems See NFPA 96 also. Fire Protection System Se I F Sprinklers / Nozzles / Fusible Links (replace) An I F/C Wetting Agent Systems See NFPA 18 also. Pre-mixed Solutions Mo T F Water Mist Systems: NFPA Water Tank, Air Receiver, Air Compressor (unsupervised) Wk I F Pump Operation Wk T F Water Tank, Air Receiver, Air Compressor (supervised) Mo I F Air Pressure Cylinders (unsupervised) Operating Components, Valves (unsupervised) Air Compressor Mo T F Air Pressure Cylinders (supervised) Qt I F Operating Components, Valves (supervised) Control Equipment (unsupervised) Qt T C Main Drain Batteries Se T C Pressure Relief Valves Control Equipment, Fiber Optic Cable Connections An I C Strainers, Filters, Piping System Pump Flow An T C System Flow Water Analysis Control Equipment (supervised), Control Unit, Water Level Switch, Release Mechanism, Detectors, Remote Alarm, Section Valve and Pressure Cylinders Water Tank (drain & refill) An PM C System Flush Pressure Cylinders 5/12yr T C
11 Page 11/14 Automatic Nozzles 20yr T C Strainers, Filters VLC PM C Detection for Water-Based Systems (See section of this table on Detection and Alarm Systems.) Gaseous and Chemical Extinguishing Systems Carbon Dioxide Systems: NFPA Tank Liquid Level (low pressure systems) Wk I F General Condition Mo I F Gas Cylinders (weighing - high pressure systems) Se T F/C Full Operation and Engineering Review An PM C Hose (hydrostatic) 5yr T C High Pressure Cylinder (hydrostatic) 5/12yr T C Halon Systems: NFPA 12A Enclosure Integrity Se I F/C Full Operation Se T C Gas Cylinders (weight or pressure) Hose (condition) An I C Gas Cylinders and Hose (hydrostatic) 5yr T C Dry Chemical Systems: NFPA General Condition Mo I F Complete System Service Se PM C Detection Devices (replace fusible metal / clean other types) An PM C Agent Containers and Hose (hydrostatic) 12yr T C Wet Chemical Systems: NFPA 17A General Condition Mo I F Complete System Service Se PM C Detection Devices (replace fusible metal / clean other types) An PM C Containers and Hose (hydrostatic) 12yr T C Clean Agent Systems: NFPA Agent Containers (quantity / pressure) Se I F Enclosure Integrity An I F Hose (condition) Complete System Service An PM C Agent Containers and Hose (hydrostatic) 5yr T C Detection for Gaseous and Chemical Extinguishing Systems (See section of this table on Detection and Alarm Systems.) Portable Fire Extinguishers: NFPA Condition, Pressure and Accessibility Mo I F Full Service An PM C Disassemble (stored pressure loaded stream type) Replace Agent (pump-type water and antifreeze / cartridge-type wetting agent)
12 Page 12/14 Replace Agent (liquid charge AFFF and FFFP) 3yr PM C Replace Agent (solid charge AFFF) 5yr PM C Replace Agent (stored pressure-types) 6yr PM C Shell and Hose (hydrostatic - varies with extinguisher type) 5/12yr T C Detection and Alarm Systems: NFPA Control Equipment (unmonitored) Wk I F Batteries (lead-acid) Mo I F Batteries (primary dry cell) Mo T F Initiating Devices (radiant energy fire detectors, supervisory signal and water flow) Qt I F/C Control Equipment (unsupervised) Qt T F/C Initiating Devices (supervisory signal) Off-premises Transmission Equipment Initiating Devices (air sampling, duct detectors, electromechanical releases, extinguishing/suppression system switches, fire alarm boxes, heat detectors and smoke detectors) Se I F Control Panel Trouble Signals Remote Annunciators, Transient Suppressors and Interface Equipment Supervised Alarm Notification Appliances Emergency Voice/Alarm Communications Equipment Guard Tour Equipment Batteries (nickel cadmium and sealed lead-acid) Initiating Devices (radiant energy fire detectors and water flow) Se T F Batteries (lead-acid, nickel cadmium) Control Equipment (monitored) An I F Fiber Optic Cable Connections Initiating Devices (duct detectors, electromechanical releases, extinguishing/suppression system switches, fire-gas detectors, heat detectors, fire alarm boxes and smoke detectors) An T C Control Equipment (supervised) Fiber Optic Cable Power Control Unit Trouble Signals Emergency Voice/Alarm Communication Equipment Guard Tour Equipment Remote Annunciators, Interface Equipment and Alarm Notification Appliances Special Hazards Equipment Initiating Devices (fixed temperature spot type heat detectors) 15yr T C Explosion Prevention Systems: NFPA System Service VLC PM C
13 Page 13/14 Emergency and Standby Power Systems: NFPA Batteries and Other Components Wk I F Generators (cold start and 30 minute run) Mo T F Other Components (exercise under load) Transfer Switches (operate) Transfer Switches VLC I F Circuit Breakers (exercise - frequency varies with type service) Se/An T F Stored Electrical Energy Emergency and Standby Power Systems: NFPA General Condition and Readings Mo I F Batteries and Charging System ECE Components Connected Load (exercise - 5 minute minimum) Qt T F Battery Charger (charge current) Batteries (electrolyte) Battery Terminals (clean) Qt PM F Battery Cable Connections Se I F ECE Terminals Transfer Switch (operate) Se T F Transfer Switch Contacts An I F/C Full Load / Full Duration An T F/C Circuit Breakers / Fuses 2yr PM F/C Lightning Protection Systems: NFPA System (visual) Se/An I F System (in-depth) 3/5yr T C System Components VLC PM C Exit Safety Components: NFPA Exits (obstructions in certain occupancies) Dy I F Exit Signs Mo I F Fire Drills (varies with occupancy) Mo/Qt / Se T F Emergency Lighting and Exit Signs (30 second functional) Mo T F Smoke Proof Enclosures (operational) Se T F/C Battery Emergency Lighting and Exit Signs (11/2 hour functional) An T F/C Air Conditioning and Ventilating Systems: NFPA 90A Plenums (apparatus casing and air handling unit) Mo I F Plenums (ceiling cavity, raised floor and duct distribution) Qt I F Fans and Motors, Ducts, Outside Air Intakes Filters (automatic - electrical controls) Se I F/C
14 Page 14/14 Smoke Detection for Automatic Shutdown An T F/C Fan Controls Dampers - Fire, Smoke and Ceiling (operational) 2 T F/C Dampers - Fire, Smoke and Ceiling (full service) 4 PM F/C Plenums, Ducts and Filters (cleaning) VLC PM F/C Smoke Control Systems: NFPA 92A Dedicated Systems (full operating sequence) Se T C Non-dedicated Systems (full operating sequence) An T C Smoke Management Systems: NFPA 92B Full Operational Se T C Smoke and Heat Vents: NFPA Mechanically Opened Vents An T F Gravity Vents VLC I F Exhaust Systems: NFPA All Components Mo I F Cleaning VLC PM F/C Fire Doors and Windows: NFPA Fire Doors, Shutters and Windows (condition) VLC I F Fire Doors (operating mechanism) VLC PM F/C Fire Doors - Sliding / Rolling (operation) An T F/C Fire Brigade Equipment: NFPA Equipment (general condition) Wk I F Pumpers - See NFPA 1911 also. An T F/C Aerial Devices - See NFPA 1914 also. An/5yr T F/C Self-contained Breathing Apparatus - See NFPA 1404 also. An PM F/C
INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT
CITY OF SPRING LAKE PARK Code Enforcement Department 1301 81 st Avenue NE Spring Lake Park MN 55432 Business Phone 763-784-6491 Fax 763-792-7257 INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS
Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more
FIRE PROTECTION SYSTEMS Fire protection systems, measures and equipment are all related to the safety of the occupants and the protection of the property. As part of a building design and its intended
ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS
ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS In this document are the fire safety equipment maintenance requirements that are found in Division B of the Alberta Fire Code (AFC 2006) for
Winnipeg Fire Department Fire Prevention Branch
Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of
INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT
INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT FIRE EXTINGUISHERS,SPRINKLER SYSTEMS AND FIRE ALARMS Attachment #1 Inspection of Fire Extinguishers Fire Extinguishers must be tested according
EXHIBIT A SCOPE OF WORK
EXHIBIT A SCOPE OF WORK 1. (Contractor) shall provide fire alarm system maintenance/repair/testing services as described herein to the California Department of Veterans Affairs (hereinafter CDVA, CalVet,
Maintaining Fire Protection Systems
Maintaining Fire Protection Systems Fire continues to be a major threat to your business and your personal safety. Each year several thousand people are injured or killed by fires and billions of dollars
TESTING, INSPECTION, AND MAINTENANCE FREQUENCIES FOR FIRE DETECTION AND ALARM SYSTEMS
TESTING, INSPECTION, AND MAINTENANCE FREQUENCIES FOR FIRE DETECTION AND ALARM SYSTEMS The following information regarding testing frequencies for fire detection and alarm systems. All of the following
Important Ontario Fire Code Information for Building Owners in the City of Windsor
Important Ontario Fire Code Information for Building Owners in the City of Windsor This information is intended to be used a reference only. For a complete listing consult the Ontario Fire Code or contact
Michael Catalano 24 Nassau Avenue, Islip NY 11751 Phone (631) 224-5477 Chief Fire Marshal [email protected] Fax (631) 224-5458
OFFICE OF THE FIRE MARSHAL BUREAU OF FIRE PREVENTION Michael Catalano, Phone Chief Fire Marshal [email protected] Fax To whom it may concern: Enclosed please find the NFPA 72 forms needed for
Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems
Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems Introduction Fire protection systems are provided in or at a building to safeguard the lives of building
MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS
FIRE DEPARTMENT Bureau of Fire Protection and Life Safety www.cityofsanmateo.org 1900 O Farrell, Suite 140 San Mateo, CA 94403-1332 (650) 522-7940 FAX: (650) 522-7941 TDD: (650) 522-7047 MAINTENANCE AND
Automatic fire-extinguishing systems for commercial cooking
Automatic fire-extinguishing systems for commercial cooking Leading Items First Ignited in Eating and Drinking Establishment Structure Fires, 2000-2004 Annual Averages Cooking materials, incl. food and
PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS
January 1997 PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS 1.0 PERMIT 1.1 After receipt of a Building Permit from the City of San Jose Building Department, submit
Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.
Large Facility Fire Safety Checklists and Logs This package contains checklists to ensure that all fire and life safety equipment are properly inspected. There are also logs on which to record the inspections
BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS
BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS Owners have numerous responsibilities as it pertains to the maintenance and operation of a building s fire safety equipment. The liabilities
CHAPTER 35 - FIRE SYSTEMS INSPECTION, TESTING, AND MAINTENANCE (ITM)
CHAPTER 35 - FIRE SYSTEMS INSPECTION, TESTING, AND MAINTENANCE (ITM) A. INTRODUCTION... 1 B. CHAPTER-SPECIFIC ROLES AND RESPONSIBILITIES... 1 1. Building Manager... 1 2. Safety Coordinator... 1 3. Office
FIVE YEAR CERTIFICATION REPORT
GARDEN GROVE FIRE DEPARTMENT FIRE PREVENTION DIVISION FIVE YEAR CERTIFICATION REPORT Service and maintenance report of automatic fire extinguishing systems, including fire sprinklers, dry, deluge, and
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
Environment of Care Fire Safety Management Plan 2014
Environment of Care Fire Safety Management Plan 2014 Updated 4.29.2014 PURPOSE The purpose of the Fire Safety Management Plan is to ensure that all facilities are designed, constructed, maintained, and
Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply
FIRE DETECTION, ALARM AND MASS NOTIFICATION SYSTEMS Inspection, testing, and maintenance of fire detection, alarm and Mass Notification systems shall be performed in accordance with the manufacturer's
Transformer Deluge Systems
Transformer Deluge Systems How Do Transformer Fires Ignite? Common causes of transformer failure: Weather-related events such as lightning Short circuits in electrical equipment The most common cause is
Inspection and Testing of Water-Based Systems
Inspection and Testing of Water-Based Systems Standard Model/Computer-Based Testing Level III Content Outline The candidate for NICET certification at Level III in the Inspection and Testing of Water-Based
Manual Document Page Issue Date TABLE OF CONTENTS
, Manual USQ #15-1163-D ESHQ 1 of 23 TABLE OF CONTENTS 1.0 PURPOSE AND SCOPE... 2 2.0 IMPLEMENTATION... 2 3.0 STANDARD... 2 3.1 Facility Management Support Requirements... 3 3.2 Fire System Discrepancy
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
Required Certification Documentation. Contractor's installation certification for range hood fire suppression systems.
OFFICE OF UNIVERSIT BUILDING OFFICIAL PROJECT/CONSTRUCTION MAGER: Sample Manager Required Aboveground only Required Certification Documentation Contractor s material and test certifications for both above
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result
F.Y.I. Specifying Fire Protection Systems Using Division 13
F.Y.I. Specifying Fire Protection Systems Using Division 13 Automatic fire sprinkler systems and fire alarm and detection systems are increasingly installed in modern buildings. Even where building codes
FIRE-FIGHTING DESIGN BRIEF REPORT
P a g e 1 SECTION 04 (Doc.No.A/DBR 001) FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 2 1.0 SCOPE 2.0 STANDARDS AND CODES 3.0 TYPES OF SYSTEM PROPOSED 4.0 FIRE HYDRANT SYSTEM 5.0 AUTOMATIC SPRINKLER SYSTEM
FIRE ALARM SYSTEM RECORD OF COMPLETION
FUNDAMENTALS OF FIRE ALARM SYSTEMS 72 33 FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. PROTECTED PROPERTY
FIRE PROTECTION SYSTEMS ACCEPTANCE INSPECTION AND TESTING PROCEDURE
ACCEPTANCE INSPECTION AND TESTING PROCEDURE Wet Pipe Sprinkler Systems...2 Dry Pipe Sprinkler Systems...2 Clean Agent Fire Extinguishing System...4 Total Flooding Systems...4 Fire Dampers...5 Smoke Dampers...5
FIRE ALARM SYSTEM RECORD OF COMPLETION
FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. Protected Property Information Name of property: Description
Inspection, Testing and Maintenance
Page 18 ABOUT CODE CORNER CCFS would like to remind you to check with your local Authority Having Jurisdiction (AHJ) for questions and opinions concerning your local Fire and Building Codes. The information
Fire Safety Plan (Single-Stage Fire Alarm System - Small Establishment)
1 Fire Safety Plan (Single-Stage Fire Alarm System - Small Establishment) Fire Safety Plan Single-Stage Fire Alarm System (small establishment) for: (Business Name) (Business Address) The reproduction
Name Of Occupancy Date. Yes No Describe
FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address
PART 1 FIRE SAFETY PLAN
Fire Safety Plan This sample fire safety plan has been developed to help owners and managers of small apartment buildings maintain compliance with Section 2.8 of the B.C. Fire Code. The plan is intended
NYC SUB-SYSTEMS INSTALLATION & SERVICE REQUIREMENTS OF THE FDNY
NYC SUB-SYSTEMS INSTALLATION & SERVICE REQUIREMENTS OF THE FDNY Presented by: James Goerl Metro Protection Systems, Inc. [email protected] Agenda Introduction & Learning Objectives History
Automatic Fire Sprinkler Submittal Requirements
Automatic Fire Sprinkler Submittal Requirements All commercial and industrial buildings with a total floor area of 5000 sq. ft. shall have an approved automatic sprinkler system installed. The Windsor-Severance
LAWS AND REGULATIONS for AUTOMATIC EXTINGUISHING SYSTEMS
DEPARTMENT OF FORESTRY AND FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING DIVISION LAWS AND REGULATIONS for AUTOMATIC EXTINGUISHING SYSTEMS AUTOMATIC EXTINGUISHING SYSTEM PROGRAM 1131
Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering
Model: 400E-2M Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Application Engineering BERMAD 1. Safety First BERMAD believes that the safety
Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS
Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS Introduction When properly installed and maintained, automatic fire sprinkler systems have proven to be the most effective means for protecting
Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1
Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1 Nuclear Power in Pakistan Nuclear Power Plants Capacity (MWe) Year of Commissioning In
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to
ACADEMY ACADEMY CUSTOMER GUIDE. ACADEMY FIRE PROTECTION (800)773-4736 www.academyfire.com. Academy Fire Protection Customer Guide.
FIRE PROTECTION CUSTOMER GUIDE THE ADVANTAGE 24/7 Fast, Reliable Service AHJ Interaction and Consultation Automated Custom Reporting Client Web Portal Dedicated Account Manager Flat Rate Price Plans Inventory
TECHNICAL ADVISORY BULLETIN
RISK CONTROL AND CLAIM ADVOCACY PRACTICE TECHNICAL ADVISORY BULLETIN November 2014 www.willis.com FIRE PUMP TESTING Fire pumps are a critical part of a fire protection system, especially when they are
Fire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment):
Fire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment): Fire Safety Plan Single-Stage Fire Alarm System for: (Business Name) (Business Address) Submission Date - Submitted by - Signature
BERMAD Fire Protection
400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad
General Fire Code Requirements Within Commercial Tenant Spaces
FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding
UNIFIED FACILITIES CRITERIA (UFC) OPERATION AND MAINTENANCE: INSPECTION, TESTING, AND MAINTENANCE OF FIRE PROTECTION SYSTEMS
UNIFIED FACILITIES CRITERIA (UFC) OPERATION AND MAINTENANCE: INSPECTION, TESTING, AND MAINTENANCE OF FIRE PROTECTION SYSTEMS APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED UNIFIED FACILITIES CRITERIA
1.0 General. Inspection, Testing, and Maintenance 1 of 8
1.0 General 1.1 Scope This specifications covers the minimum requirements for the inspection, testing, and maintenance of the existing Notifier fire alarm systems at Bergen Community College (BCC) campus
FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.
Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's
PLAN REVIEW GUIDE FOR FIRE ALARM
PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical
Appendix B Forms for Inspection, Testing, and Maintenance
Appendix B Forms for Inspection, Testing, and Maintenance This appendix is not a part of the requirements of this NFPA document but is included for informational purposes only. Forms need to be complete
FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL
FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:
BERMAD Fire Protection
Model: 400E-2M BERMAD Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Safety First BERMAD believes that the safety of personnel working with and around
INSPECTION, TESTING AND MAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS
GAP.12.0.1 A Publication of Global Asset Protection Services LLC INSPECTION, TESTING AND MAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS INTRODUCTION National Fire Protection Association (NFPA) documents
INSPECTION AND TESTING OF EMERGENCY GENERATORS
INSPECTION AND TESTING OF EMERGENCY GENERATORS Certification requirements NFPA 101(00), Sec. 7.9.2.3 requires that emergency generators be installed, tested and maintained in accordance with NFPA 110,
Fighting Fire in Sprinklered Buildings. Student Guide
Fighting Fire in Sprinklered Buildings Student Guide Fighting Fire in Sprinklered Buildings Student Guide Table of Contents Purpose........................................................... 3 Instruction
Commercial Fire Inspections
Commercial Fire Inspections Fire Department Inspection Requests and Procedures The following guidelines shall be used when calling for inspection requests: 1. All inspection requests shall be coordinated
Duke University Hospital Fire/Life Safety Management Plan 2007
Duke University Hospital Fire/Life Safety Management Plan 2007 Introduction One of the most serious issues facing Duke University Hospital, Medical Center, Duke Clinic and the Health Systems is the threat
FIRE PROTECTION SYSTEMS
CHAPTER 9 FIRE PROTECTION SYSTEMS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall apply to the inspection, operation, testing and maintenance of all fire protection systems. 901.2.
Program No. 1.6.1. Section Heading
ENVIRONMENTAL HEALTH AND SAFETY EHS PROGRAM MANUAL Program Title 1.0 INTRODUCTION The New York City Fire Department (FDNY) is responsible for approving and/or inspecting fire alarm systems, buildings,
SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT
SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT INTRODUCTION No matter how reliable fire protection equipment may seem, periodic maintenance is needed to ensure proper operation. Fire protection
FOR CERTIFICATION AS PRESCRIBED BY THE STATE FIRE PREVENTION COMMISSION ON NOVEMBER 11, 2009 IN ACCORDANCE WITH THE STATE FIRE PREVENTION REGULATIONS
EXAMINATION REQUIREMENTS FOR FIRE SUPPRESSION SYSTEM CERTIFICATION AS PRESCRIBED BY THE STATE FIRE PREVENTION COMMISSION ON NOVEMBER 11, 2009 IN ACCORDANCE WITH THE STATE FIRE PREVENTION REGULATIONS REGULATION
FPS4 APPENDIX A (INTERIM) SPECIFICATION FOR THE INSPECTION AND TESTING OF AUTOMATIC FIRE SPRINKLER SYSTEMS
FPS4 APPENDIX A (INTERIM) SPECIFICATION FOR THE INSPECTION AND TESTING OF AUTOMATIC FIRE SPRINKLER SYSTEMS To be used in conjunction with the Fire Protection Association Australia FPS4-2000: Agreement
FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY
FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Addressable interface
SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT
SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT The purpose of these specifications is to insure that there are minimum
Fire Alarm System Monitoring - CAN/ULC-S561-03
Fire Alarm System Monitoring - CAN/ULC-S561-03 Brian McBain ULC Regulatory Services May 4, 2011 Copyright 1995-2007 Underwriters' Laboratories of Canada. All rights reserved. No portion of this material
Sprinkler and Fire Alarm Systems for the Building Official
Sprinkler and for the Building Official Randall Kovacs, P.Eng., CP, FEC Gage-Babcock & Associates, Ltd. Topics Coordinated System Testing 1 Wet Dry Pre-action Deluge Wet System: Pipes filled with water
Inspection and Testing Program Fire Protection Equipment
I. Introduction Inspection and Testing Program Fire Protection Equipment State of Minnesota Emergencies seldom give warning before they strike. Thus, it is essential that fire protection equipment be inspected,
2014 Limited Plan Submittal Checklist
City of Aurora Public Works Department WET AND DRY CHEMICAL HOOD SUPPRESSION SYSTEM 2014 Limited Plan Submittal Checklist Building Division 15151 E. Alameda Parkway, Ste 2400 Aurora, CO 80012 303-739-7420
FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION
FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this
Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
VOLUNTEER FIRE WARDENS
FIRE PRE-PLAN FACILITIES SERVICES VOLUNTEER FIRE WARDENS & EMERGENCY RESPONSE MEMBERS KEELE CAMPUS & GLENDON CAMPUS Ken Wong, P.Eng. SFPE. Mgr., Building Code / Fire Protection Code Compliance Facilities
DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION
Phone System Owner Phone System Engineered by: of Record Drawings: of System Manuals: of Test Reports: System Installer 1. GENERAL INFORMATION Phone Delaware License No: Certificate Holder No. System Supplier
SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
HERNANDO COUNTY FIRE ALARM GUIDELINES
HERNANDO COUNTY FIRE ALARM GUIDELINES To be used for all commercial building fire alarm system plan review. The procedures set forth in this document are the minimum requirements necessary to ensure a
(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;
(1979) (Rev.1 1990) (Rev.2 1996) (Rev.3 Jan 2012) Safety features.1 Fire protection and extinction.1.1 General Fire protection arrangements and fire extinguishing systems are to be in accordance with the
SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS
SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS I. APPLICATION AND DEFINITIONS 1.01 Authorization for Standards 1.02 Application of Standards 1.03 Definitions
Ethanol Vehicle and Infrastructure Codes and Standards Citations
Ethanol Vehicle and Infrastructure Codes and Standards Citations This document lists codes and standards typically used for U.S. ethanol vehicle and infrastructure projects. To determine which codes and
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or
presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Monday, 17 June, 13
presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Who is the AFSA? Safe and Secure Alberta Fire Safety Association Fire industry members working together to improve
FIRE SAFETY PLAN FOR KITCHENER, ONTARIO
FIRE SAFETY PLAN FOR KITCHENER, ONTARIO Additional information of fire safety plans may be found at our website at www.kitchener.ca/fire.htm. Before submission, please read and change all sections to address
Recommended Practice for Installation of Transit Vehicle Fire Protection Systems
Recommended Practice for Installation of Transit Vehicle Fire Protection Systems Approved October 25, 2007 APTA Fire Safety Working Group Approved May 3, 2008 APTA Bus Safety Committee Approved October
PANAMA MARITIME AUTHORITY MERCHANT MARINE CIRCULAR MMC-281
PANAMA MARITIME AUTHORITY MERCHANT MARINE CIRCULAR MMC-281 PanCanal Building Albrook, Panama City Republic of Panama Tel: (507) 501-5355 [email protected] To: Ship-owners/Operators, Company Security
NATIONAL FIRE ALARM AND SIGNALING CODE
GAP.11.1.1.0 A Publication of Global Asset Protection Services LLC NATIONAL FIRE ALARM AND SIGNALING CODE INTRODUCTION National Fire Protection Association (NFPA) documents describe a level of fire protection
KODAK VERSAMARK, INC.
KODAK VERSAMARK, INC. PREPARED BY : Gary Rowland 6/6/06 Kodak Versamark, Inc. 3000 Research Blvd. Dayton, Ohio 45420 APPROVED BY : Fire Suppression System Inspection, Testing and Maintenance SHEET 1 OF
FIRE PROTECTION SYSTEMS
CHAPTER 9 FIRE PROTECTION SYSTEMS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall specify where fire protection systems are required and shall apply to the design, installation and
Trace Electric Trace Fire Protection
ELECTRIC AL FIRE PROTECTION ACTIVE IN THE FOLLOWING AREAS: Multi-Unit Residential Apartment Buildings Industrial Commercial Institutional & Long Term Care Facilities Trace Electric Trace Fire Protection
FIRE SAFETY PLAN 123 TOWER STREET CAMBRIDGE, ONTARIO
S A M P L E FIRE SAFETY PLAN 123 TOWER STREET CAMBRIDGE, ONTARIO This sample Fire Safety Plan can be used to assist in developing a Fire Safety Plan for your building. TABLE OF CONTENTS 1. HUMAN RESOURCES
Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection
Aerosol Fire Suppression Your Choice for Special Hazard Fire Protection Traditional Special Hazard Fire Protection Centers Around Two Technologies Water deluge and chemical agent fixed systems protect
Rhode Island State Fire Marshal Fire Protection Systems Narrative Reports. What is a Narrative Report?
RHODE ISLAND DIVISION OF STATE FIRE MARSHAL 1951 Smith Street, North Providence, RI 02911 Telephone: (401) 383-7717 Fax: (401) 383-8879 John E. Chartier, EFO, CFI State Fire Marshal Rhode Island State
FIRE ALARM AND DETECTION SYSTEMS SECTION 16721
PART 1 - GENERAL 1.01 WORK INCLUDED FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 A. Provide a complete fully addressable, power limited, fire detection and evacuation system. The system shall be connected
Facilities Maintenance Standards rev 9-1-2015
Facilities Maintenance Standards rev 9-1-2015 Purpose The purpose of these standards is to outline the minimum requirements for maintaining state owned facilities and infrastructures in a manner that will
SECTION 16721 FIRE ALARM AND DETECTION SYSTEM
1. GENERAL 1.1. Related Documents: 1.2. Scope: 1.1.1. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements apply to the work specified in this
NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet
This Commercial Kitchen Automatic Fire has been created to assure all documentation has been submitted to assist you in assuring proper plans and documentations has been submitted and reviewed by New Mexico