Presentation of the TRACE LABORATORY. Petra Přibylová Head of Trace laboratory
|
|
- Juliet Walsh
- 8 years ago
- Views:
Transcription
1 Presentation of the TRACE LABORATORY Petra Přibylová Head of Trace laboratory
2 Laboratory of the trace analysis - accreditation "Accredo - put faith in"» Matrices: - Outdoor / indoor air - Surface water - Sediments, soils - Food, foodstuffs - Cell tissues - Secretions and excretions incl. Breast milk Analytes: - PCDDs/Fs, dl-pcbs, ind. PCBs - PBDEs GC/ HRMS
3 Samples flow
4 Struktura Stopové laboratoře Vedoucí: Petra Přibylová Odborný garant: Anton Kočan Manažer kvality: Rostislav Červenka Inetrní auditoři: Rostislav Červenka Iva Poláková Metrolog: Rostislav Červenka Laboratorní specialista I: Iva Poláková Lenka Vaňková Laboratorní specialista II: Ondřej Audy Jitka Bečanová Eliška Čechová Jiří Kohoutek Rostislav Červenka Pavlína Karásková Tono Kočan Petr Kukučka Jan Kuta Petra Přibylová Marta Seifertová Šimon Vojta Technik: Lída Tupová Eva Krejčí
5 PEOPLE WORKING IN THE LAB Tono Kočan Petra Přibylová Rosťa Červenka Eva Krejčí Trace Lab Staff: Roman Prokeš Jiří Kohoutek Lenka Vaňková Iva Poláková Lída Tupová Tono Kočan Petr Kukučka Šimon Vojta Jitka Bečanová Jiří Kohoutek jr. Jan Kuta Rosťa Červenka PhD. Students working on the projects: Ondřej Audy Pavlína Karásková Eliška Čechová Marta Seifertová Non-trace lab staff, entrance just for measurements: Zdeněk Šimek, Brano Vrana, Lisa Melymuk, Lucie Bláhová SELECTED STUDENTS UNDER CONTROL OF THEIR SUPERVISORS!!!! IN INSTRUMENTAL ROOMS ONLY!!!!
6 Laboratory of the trace analysis Equipment: 2 x GC/HRMS dl-pcbs, PCDDs/Fs, pyrethroids, BFRs = PBDEs, NBFRs 4 x GC/MS/MS ind.pcbs, OCPs, cyclodiene pesticides (including endosulphane), PAHs, N-PAHs, OPFRs 3 x GC/MS - PAHs, musks, personal care products GC/ECDxFID alkalnes, OCPs HPLC/ MS alkylphenols, estrogens HPLC/ MS/MS CUPs, pharmaceuticals, HBCDs, PFCs, microcystins, oxidative stress markers ICP / MS metals GC (LS)/ ICP/MS speciation analysis AAS - Hg
7 GC/ECD + FID Jaromír Literák (responsible person) Tono Kočan (the second floor 212)
8 GC 7890 / FID/ECD (Agilent) Tono Kočan, Jaromír Literák GC/ECD PCBs + OCPs (Tono Kočan) Enantioselective measurements (Jaromír Literák) GC/FID Aliphatic hydrocarbons Alkyl-PAHs PAHs (Jaromír Literák)
9 Organic and inorganic carbon determination Ondřej Mikeš (responsible person) Rosťa Červenka (analysis for TL) (the second floor 212)
10 Organic and Inorganic carbon determination Room: 212 Persn.: Ondřej Mikeš (Klára Šmídová, Rosťa Červenka) High temperature digestion of the sample Liquids 0 60,000 mg/l in liquids % in solids NDIR detection Solids LOD 6 μg/l (ppb) - liquids reagent water drinking water waste water sea water saline solutions electrolytes particles suspensions soils slurries residues solids Next- Organic and elementar carbon in the air samples
11 Structure of the trace lab Sampling Samples preparation Analysis
12 SAMPLE PREPARATION IN THE TRACE LAB Samples evidence Iva Poláková, Lenka Vaňková, Lída Tupová Cleaning (preextraction) of the sampling media before the exposure (Soxhlet extraction) Extraction of the samples (Automated hot solvent extractors Büchi B-811, SPE) Analytical clean-up (adsorption column chromatography on the different sorbents, GPC) Groups of compounds: - PCBs, OCPs, Drin pesticides, PBDEs, HBCDDs, PBBs, NBFRs, PAHs - NEWLY: PCDDs/Fs - FUTURE PFCs, CUPs
13 GC 7890 / MS-MS Triple Quadrupole 7000B (Agilent) Petra Přibylová (responsible person) Ondra Audy Petr Kukučka (the second floor 232)
14 Group of compounds: PCBs + OCPs, PAHs native and 13C labeled -Monitoring: AIR (MONET projects 2900 analysis/year), Košetice projects 130a/y) Water (Košetice RW 240 a/y) Soil, sediment, needles, moss (Košetice 100a/y) -Projects Gerhard s project (~1300a/y), ArcRisk/Monairnet, Fluvisoils, Anděl autoroute monitoring, Mokrá cement factory, Luca s projects, Water s group projects (~1700 a/y) -Calibration studies (~1200 a/y) -Indoor studies (? a/y) - Samples for the methods validation (~200s/y) Capacity samples/day ~ 8000 analysis / 2014
15 GC-LRMS: GC 6890N / MSD 5975 (Agilent) Single quadrupole EI (SIM, SCAN) Brano Vrana (responsible person) Petra Přibylová Tono Kočan Petr Kukučka Ondra Audy (the second floor 233)
16 Until NOW: PAHs measurements - Monitoring (MONET projects, Košetice projects) - Projects Monairnet, Fluvisoils, Anděl, Karla s samples, calibration studies, some student s projects) -NEAR FUTURE: -PAHs for Brano -Methods development - MUSK compounds - Alkyl phosphates? - Pyrethroids? Projects of Brano Capacity samples/day
17 GC/MS-MS Quattro Micro GC (Waters) Petr Kukučka (responsible person) (the second floor 232)
18 Until NOW: PCBs + OCPs, cyklodiene pesticides measurements - Monitoring (MONET projects, Košetice projects) -NEAR FUTURE: MS/MS Methods development -CI ionization possible - MUSK compounds - Alkyl phosphates? - Pyrethroids?
19 GC 7890 / APGC MS-MS XEVO TQ-S (Agilent-Waters) Petr Kukučka (responsible person) Ondra Audy (the second floor 232)
20 Projects only New method development Substituted PAHs Alkyl phospates? Organophosphorus flame retardands SCCPs/MCCPs?
21 High Resolution GC/MS THERMO Scientific DFS Tono Kočan (responsible person) Eliška Čechová Marta Seifertová Šimon Vojta (the basement 1S05)
22 High Resolution GC/MS THERMO Scientific DFS PCDD/Fs 60m Rtx-Dioxin 2 column (Restek) dl-pcbs 60m DB5-MS UI column (Agilent) Pyrethroids Predicted capacity of 1500 samples per year in accreditation mode (QA/QC assurance)
23 High Resolution GC/MS AutoSpec Premier (Waters) Petr Kukučka (responsible person) Šimon Vojta Tono Kočan Ondra Audy (the basement 1S31)
24 AutoSpec Premier, Agilent 7890A PBDEs, PBBs Novel BFRs 15m DB5 column, (Restek 1614, to be delivered), S/SL inlet, PTV inlet (Gerstel CIS3), short GC runtime sample throughput on average ~20-40 samples/day
25 LC-MS/MS Agilent 1290 and ABSciex QTRAP 5500 Waters Acquity and XEVO TQ-S (QqQ) unit resolution Agilent 1290/7890 and 6550 (Qtof) high resolution Jiří Kohoutek (responsible person) Jitka Bečanová Zdeněk Šimek Lucie Bláhová (the second floor 229, 231)
26 LC-MS/MS analysis Analysis: PFCs (perfluorinated compounds) HBCD (hexabromocyclododecane) Chlordecone CUPs (currently used pesticides) and degradation products Estrogens, Pharmaceuticals, Sweeteners Secondary metabolites of cyanobacteria and conjugates Fytoestrogenes Matrices: water, sediment air samples - PUF/QUARTZ/XAD materials, biological samples Instrumentation: Agilent 1290 and ABSciex QTRAP 5500 Capacity: cca analyses per year
27 Target and non-target LC-MS analysis (Jiří Kohoutek, Zdeněk Šimek) - quantitative and qualitative analysis of organic compounds - various matrices (water, sediment, biological samples, ) - LC (NP, RP, HILIC) and GC (SPME option) separation techniques - ESI, APCI and APPI ionization Instrumentation: Waters Acquity and XEVO TQ-S (QqQ) unit resolution Agilent 1290/7890 and 6550 (Qtof) high resolution
28 Analysis of metals, speciation analysis Jan Kuta Rosťa Červenka Blanka Maňáková (the second floor 214)
29 Analysis of metals, speciation analysis Jan Kuta, Rostislav Červenka, Blanka Maňáková Analysis of total content of elements (a large part of the periodic table) in various matrices e.g. sediment and soil samples, biota samples, air samples (dust on nitrocelullose filters)... Metals in specific leachates from soils and sediments Speciation of selected elements using hyphenated methods LC/GC-ICP-MS - As, Se, Hg (Cr, organo-sn) Instruments ICP-MS: Agilent 7500ce, Agilent 7700x HPLC: Agilent 1100 GC: Agilent 6890
30 Analysis of metals, speciation analysis Jan Kuta, Rostislav Červenka, Blanka Maňáková Hg analysis Altec AMA254 solid sampling AAS Hg analyzer Contact persons: Rostislav Červenka, Jan Kuta Solid sampling AAS total content without sample extraction (grinded sample) Sample preparation Contact persons: Jan Kuta, Rostislav Červenka, Blanka Maňáková Microwave digestion system MW3+ Berghof Ball Mill Retsch MM301 for grinding of samples Thermoblock, horizontal shaker, hot plates system for sub-boil distillation of acids, centrifuge...
31 Direct cooperation between teams of TL and GENASIS GENASIS: on-line processing of data ( Data analyses Interactive risk assessment case studies GIS visualization and space-time modelling
32 Thank you for your attention!
Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific
Pesticide residue analysis: New Trends Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific Why pesticide analysis? Extensively used in agriculture to control
More informationHow To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
More informationNANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT
NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT AND ANALYSIS SEPTEMBER 2012, V 1.1 4878 RONSON CT STE K SAN DIEGO, CA 92111 858-565 - 4227 NANOCOMPOSIX.COM Note to the Reader: We at nanocomposix have published
More informationAutomation of Solid Phase Extraction and Column Chromatographic Cleanup
Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for
More informationOverview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction
Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)
More informationWATERS QUANTITATIVE ANALYSIS solutions
More sensitivity. More speed. What more can you ask for in a complete quantitative analysis solution? WATERS QUANTITATIVE ANALYSIS solutions THE CHALLENGE OF QUANTITATIVE ANALYSIS Tandem mass spectrometry,
More informationHORIZONTAL concerning the layout, editorial and technical content, this document needs revising. In order to harmonize all documents within
Template for s and secretariat Date: 006-06-30 Document: CEN/BT/TF 151/TG 4 N0013 Horizontal 4.7 BFR Author s: ALL; Replies: TG 4 1 (3) 4 5 (6) (7) on each submitted NL ge This document is poorly attuned
More informationAnalysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS-1603. No. SSI-GCMS-1603. Shilpi Chopra, Ph.D.
Gas Chromatograph Mass Spectrometer No. GCMS-1603 Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS Shilpi Chopra, Ph.D. Introduction Organophosphorus (OP) pesticides are a class
More informationOur staff... Our power
ABOUT US... Centro Analisi Biochimiche, thanks to its multiyear experience and its staff s competence, succeeded to achieve during these years an increasing prestige in analitical and advice services,
More informationThis study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA
An Automated Method for the Fractionation of Extractable Petroleum Hydrocarbons (EPH) from Water and Soil Extracts Using the Gilson GX-274 ASPEC System Keywords: Aliphatic Hydrocarbons, Aromatic Hydrocarbons,
More informationAPI 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined
API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation
More information# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water
Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system
More informationMICROORGANIC POLLUTANTS: ACTION NEEDED TO SIMPLIFY THEIR ANALYSIS
MICROORGANIC POLLUTANTS: ACTION NEEDED TO SIMPLIFY THEIR ANALYSIS Mosca S., Guerriero E., Rotatori M. The analysis of PCDD/Fs, PCBs and other related compounds requires complex analytical procedures using
More informationS olid Ph ase Extraction (SP E) Method:
Solid Phase Extraction of US EPA 535 for Chloroacetanilide and Acetamide Degradates in Drinking Water Samples Prior to Liquid Chromatography/ Tandem Mass Spectrometry Toni Hofhine, Horizon Technology,
More informationLC-MS/MS, the new reference method for mycotoxin analysis
LC-MS/MS, the new reference method for mycotoxin analysis What is necessary for the implementation of the multi-residue mycotoxin method in an analytical laboratory? Azel Swemmer azel@fdalab.co.za AFMA
More informationInnovative vs Traditional
And in the red corner, introducing the challenger NASDAQ April 4 2011 243.47 $ 1.38 $ 0.58 % 0.07 $ 0.02 $ 39.4 % Technology DVD Digital Streamline Instant Play Internet Access Unlimited Selection No Late
More informationLC-MS/MS for Chromatographers
LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS, with an emphasis on the analysis of drugs in biological matrices LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS,
More informationA High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS
A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS AB SCIEX QTRAP 4500 LC/MS/MS System and Gerstel, Inc. MultiPurpose Sampler
More information6. ANALYTICAL METHODS
45 6.1 BIOLOGICAL MATERIALS No methods were located that are routinely used for the detection of BCEE in biological materials. Norpoth et al. (1986) reported a method for measuring thiodiglycolic acid
More informationAdvancing the State of Analytical Science. for air, water and soil analysis. and beyond
Advancing the State of Analytical Science for air, water and soil analysis and beyond Full Spectrum of Services SEMICONDUCTOR SECTOR ENVIRONMENTAL INDUSTRY HIGH TECHNOLOGY R&D Process Analysis Substrate,
More informationAnalysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Stephen Lock 1 and Matthew Noestheden 2 1 AB SCIEX Warrington, Cheshire (UK), 2 AB SCIEX Concord, Ontario (Canada) Overview A rapid,
More informationUHPLC/MS: An Efficient Tool for Determination of Illicit Drugs
Application Note: 439 UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela UHPLC System MSQ Plus MS Detector Drugs
More informationMEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process
- Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples
More informationUsing Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract
Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate
More informationChemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample
More informationDetermination of Polycyclic Aromatic Hydrocarbons (PAH) in Food with GC-MS/MS
Determination of Polycyclic Aromatic Hydrocarbons (PAH) in Food with GC-MS/MS Thorsten Bernsmann, Peter Fürst Chemical and Veterinary Analytical Institute Münsterland-Emscher-Lippe Joseph-König-Str. 40,
More informationAnalysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column
Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column Sachiki Shimizu, FUJIFILM Fine Chemicals Co., Ltd., Kanagawa, Japan Kenneth J. Fountain, Kevin Jenkins, and Yoko Tsuda,
More informationHow To Get A Laboratory License In Washington
Application for Initial Certification as a Third-Party Laboratory allowed to conduct required quality assurance tests under WAC 314-55-102 V.1.0 Overview An expectation of the Washington State Liquor Control
More informationNUVISAN Pharma Services
NUVISAN Pharma Services CESI MS Now available! 1st CRO in Europe! At the highest levels of quality. LABORATORY SERVICES Equipment update STATE OF THE ART AT NUVISAN CESI MS Now available! 1st CRO in Europe!
More informationA Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015
A Navigation through the Tracefinder Software Structure and Workflow Options Frans Schoutsen Pesticide Symposium Prague 27 April 2015 Kings day in The Netherlands 1 Index Introduction Acquisition, Method
More informationMultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples
MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples Fast and Efficient Data Review, with Automatic Flagging of Outlier Results Adrian M. Taylor and Michael
More informationFipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup
Application Note 25570306 Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup Keywords Gel Permeation Chromatography GPC AutoPrep 2000 Pesticides RapidVap N2 System
More informationSimultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF
Simultaneous qualitative and quantitative analysis using the Agilent 654 Accurate-Mass Q-TOF Technical Overview Authors Pat Perkins Anabel Fandino Lester Taylor Agilent Technologies, Inc. Santa Clara,
More informationOverview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System
Investigating the use of the AB SCIEX TripleTOF 4600 LC/MS/MS System for High Throughput Screening of Synthetic Cannabinoids/Metabolites in Human Urine AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS
More informationATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS
1 ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS Buck Scientific Atomic Absorption Spectrophotometer, Model 200 Atomic absorption spectroscopy (AAS) has for many years
More informationExtraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum
Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in uman Serum Technical verview Clinical Research Authors Anthony Macherone, Ph.D. Agilent Technologies,
More informationAgilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS
Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS AGILENT 6000 SERIES LC/MS SOLUTIONS UNRIVALED ACHIEVEMENT AT EVERY LEVEL The Agilent 6000 Series of LC/MS instruments
More informationThe Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis
The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis Stephen Lock AB SCIEX Warrington (UK) Overview A rapid, robust, sensitive and specific LC-MS/MS method has been developed for
More informationMethod development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report
of melamine-ware by GC-MS and LC-MS/MS Page 1 of 15 Method development for analysis of formaldehyde in foodsimulant extracts of melamine-ware by GC-MS and LC-MS/MS December 2012 Contact Point: Chris Hopley
More informationAMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
More informationRapidFire High-throughput MS technology. Enhancing Drug Discovery Turning Mass Specs into Plate Readers
RapidFire High-throughput MS technology Enhancing Drug Discovery Turning Mass Specs into Plate Readers 1 Drug Discovery with RapidFire Target Selection High-throughput Target Screening (HTS) Lead Optimization
More informationAUTOMATED SAMPLE PREP CAPITAL EXPENDITURE JUSTIFICATION REPORT
AUTOMATED SAMPLE PREP CAPITAL EXPENDITURE JUSTIFICATION REPORT Purchase of Solid Phase Extraction Equipment EXECUTIVE SUMMARY Any Environmental Lab Commercial Laboratory Operation requests funds in the
More informationGuide to Reverse Phase SpinColumns Chromatography for Sample Prep
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10
More informationINTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS
AxION iqt GC/MS/MS INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE IDENTIFY WHAT YOU RE LOOKING FOR (AND EVEN WHAT YOU RE NOT) The GC/MS/MS Solution for the Work You Do The ideal solution for industrial,
More informationDetection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS
Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS D. Loeffler 1, M. Ramil 1, T. Ternes 1, M. Suter 2, R. Schönenberger 2, H.-R. Aerni 2, S, König, A. Besa,
More informationThermo Scientific HyperSep Solid Phase Extraction Method Development Guide
chromatography Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide The following guide provides considerations, tips and general guidelines for developing SPE methods using the Thermo
More informationAppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT
AppNote 9/2013 Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides Oscar G. Cabrices Gerstel, Inc., 701 Digital Dr. Suite J, Linthicum, MD 21090, USA
More informationAgilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES
Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES AGILENT ENHANCED MATRIX REMOVAL LIPID ARE LIPIDS WEIGHING YOUR SAMPLES DOWN? Interference from lipids is a problem for labs measuring
More informationMassHunter for Agilent GC/MS & GC/MS/MS
MassHunter for Agilent GC/MS & GC/MS/MS Next Generation Data Analysis Software Presented by : Terry Harper GC/MS Product Specialist 1 Outline of Topics Topic 1: Introduction to MassHunter Topic 2: Data
More information泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics
泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics 2014 Training Course Wei-Hung Chang ( 張 瑋 宏 ) ABRC, Academia
More informationAnalysis of Veterinary Drug Residues in China
Analysis of Veterinary Drug Residues in China Dr. Xionghai Yi( 伊 雄 海 ) Shanghai Entry-Exit Inspection and Quarantine Bureau of The People s Republic of China SEP. 10, 2014 Contents Profile of the institution
More informationWhich analytical tools/instruments/techniques are used for POPs. A general walk through the analysis
Which analytical tools/instruments/techniques are used for POPs A general walk through the analysis Kay Kelterer Eurofins GfA Lab Service GmbH Großmoorbogen 25, 21079 Hamburg, Germany 23.04.2015 Miljøgifter
More informationBiopharmaceutical Glycosylation Analysis
Biopharmaceutical Glycosylation Analysis Glycosylation Analysis: Product Offering Molecular model of erythropoietin with complex N-linked glycans. Courtesy of M.R Wormald and R.A Dwek, Oxford Glycobioloy
More informationSupplementary Materials and Methods (Metabolomics analysis)
Supplementary Materials and Methods (Metabolomics analysis) Metabolite extraction and mass spectrometry analysis. 12 Vldlr-/- knock out and 12 wild type (WT) retinas were separately frozen at -80 ºC in
More informationLC Application Note. www.palsystem.com
LC Application Note Pain Management & Drugs of Abuse Measured in Urine or Oral Fluid Measuring all the drugs at all the relevant concentrations in a single method / workflow using an ITSP solution for
More informationThermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs
Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex
More informationLipid analysis by multiple "omic" mass spectrometry platforms Where we ve been, where we are, and where we re going
Lipid analysis by multiple "omic" mass spectrometry platforms Where we ve been, where we are, and where we re going Jeff McDonald Department of Molecular Genetics UT Southwestern Medical Center Dallas,
More informationHydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns
Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns Jonathan P. Danaceau, Kenneth J. Fountain, and Erin E. Chambers Waters
More informationaurora M90 Innovation with Integrity A new era in ICP-MS ICP-MS
aurora M90 A new era in ICP-MS Innovation with Integrity ICP-MS Your Partner in ICP-MS Solutions Bruker continues to find new and novel ways to meet your changing needs. As a leader in elemental analysis
More informationDetermination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection
Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Application Note 1097 Liu Qian, Zheng Hongguo and
More informationSCION SQ Series GC-MS
SCION SQ Series GC-MS The Gas Chromatographers Detector SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative
More informationWaters Core Chromatography Training (2 Days)
2015 Page 2 Waters Core Chromatography Training (2 Days) The learning objective of this two day course is to teach the user core chromatography, system and software fundamentals in an outcomes based approach.
More informationGas Chromatography Liner Selection Guide
Gas Chromatography Liner Selection Guide Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20551 Key Words Liner, focus Abstract The liner serves an important function in allowing
More informationExtraction of Cannabinoids in Marijuana and Edibles by QuEChERS
Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS UCT Part Numbers: ECQUEU750CT-MP - QuEChERS, Mylar packs containing 4 g magnesium sulfate, 1 g sodium chloride, 0.5 g sodium citrate dibasic
More informationThe First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies
The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies INEF Penn State Conference 2013 Albert Robbat, Jr. and Patrick Antle Tufts University, Chemistry
More informationApplication of ICP-MS as a Tool for Environmental Monitoring. Bill Spence Environmental Market Specialist
Application of ICP-MS as a Tool for Environmental Monitoring Bill Spence Environmental Market Specialist Introduction Knowledge of the concentration of metallic species in the environment has been important
More informationLC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,
More informationCliquid ChemoView 3.0 Software Simple automated analysis, from sample to report
PRODUCT BULLETIN Cliquid ChemoView 3.0 Software for Routine Screening and Quantitation Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report KEY FEATURES Secure user login that
More information2011 Waters Corporation
2011 Waters Corporation Waters Overview Introduction to Waters Established in 1958 Publicly traded corporation (NYSE:WAT) $1.84 billion in annual revenue Headquartered in Milford, Massachusetts Manufacturing
More informationSIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC
SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC Katja SÄRKKÄ, Kari ARINIEMI, Pirjo LILLSUNDE Laboratory of Substance Abuse, National Public Health Institute Manerheimintie,
More informationDelivering a. New Era. of Technical. Support Services
Delivering a New Era of Technical Support Services 1 Constantly setting new and unique standards for the quality of our products and support of our customers Jeff Layne, Ph.D. Technical Manager, Phenologix
More informationThermo Scientific Training Courses. The key to your laboratory s success. 2016 Training Programme UK and Ireland
Thermo Scientific Training Courses The key to your laboratory s success 2016 Training Programme UK and Ireland Invest in Yourself People are the most valuable assets in any lab. We offer comprehensive,
More informationBiocides main groups
Analytical challenges for the analysis of biocides in aqueous and solid environmental matrices Arne Wick, Kathrin Broeder, Michael Schluesener, Thomas Ternes Federal Institute of Hydrology (BfG), Koblenz,
More informationHolcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants
Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants Version 2004-01 / August 2004 (HGRS-JW-04-25s) HGRS-CTS/MT J. Waltisberg SUMMARY ( ) shall not
More informationAppNote 10/2012. Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages KEYWORDS
AppNote 10/2012 Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages T. Albinus, K. MacNamara Gerstel GmbH & Co. KG, Eberhard-Gerstel-Platz
More informationChemical analysis service, Turner s Green Technology Group
Chemical analysis service, Turner s Green Technology Group Hourly costs, Academic collaborations leading to co-publications: 627 SEK/hr (excl. VAT) Hourly costs, Industry/Academic collaborations, no publications:
More informationUNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850
UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850 Test Method: CPSC-CH-E1001-08.2 Standard Operating Procedure
More informationSPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from uman Plasma Krishna Rao Dara, Dr. Tushar N. Mehta, Asia Pacific Center of Excellence, Thermo Fisher Scientific, Ahmedabad, India Application
More informationExtraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis
Application Note AN844 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Page 1 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Introduction Catecholamines
More informationHS 1003 Part 2 HS 1003 Heavy Metals Test
HS 1003 Heavy Metals Test 1. Purpose This test method is used to analyse the heavy metal content in an aliquot portion of stabilised hot acetic acid extract by Atomic Absorption Spectroscopy (AAS). Note:
More informationState Water Resources Control Board Environmental Laboratory Accreditation Program
State Water Resources Control Board Environmental Laboratory Accreditation Program P.O. Box 100, Floor 24 850 Marina Bay Parkway, Build. P 500 N Central Ave, Suite 500 Sacramento, CA 95812-0100 Richmond,
More informationQuantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay
PO-CON1484E Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching ASMS 014 TP85 David R. Baker 1, John Warrander 1, Neil Loftus 1, Simon Hird
More informationAppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT
AppNote 1/2014 Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine Fred D. Foster, John R. Stuff, Edward A. Pfannkoch GERSTEL, Inc., 701 Digital Dr. Suite J,
More informationChapter 28: High-Performance Liquid Chromatography (HPLC)
Chapter 28: High-Performance Liquid Chromatography (HPLC) Scope Instrumentation eluants, injectors, columns Modes of HPLC Partition chromatography Adsorption chromatography Ion chromatography Size exclusion
More informationSimultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs
Liquid Chromatography Mass Spectrometry SSI-LCMS-068 Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs LCMS-8050 Summary By utilizing the LCMS-8050 s ultrafast scan
More informationAccurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances
Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances TripleTOF 5600 + LC/MS/MS System with MasterView Software Adrian M. Taylor AB Sciex Concord, Ontario (Canada) Overview
More informationof Biologics Using LC/MS in Compliant Laboratories
Demonstrating Comparability and Consistency of Biologics Using LC/MS in Compliant Laboratories Patrick Boyce Biopharmaceutical Marketing Manager Europe & India Waters 2011 Waters Corporation Overview Challenges
More informationCONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in
More informationThe laboratory fulfils the requirements for periodic emission measurement according to ČSN P CEN/TS 15675:2009
Page 1 of 8 Testing laboratory working site: Working place 1: Technické služby ochrany ovzduší Praha a.s. Testing Laboratory for Measuring Pollutants, Jenečská 146/44, 161 00 Praha Working place 3: Organizational
More informationIncreasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening
Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening Application Note Forensics Author Erin Shonsey Director of Research Alabama Department of Forensic Science Abstract
More informationDetermination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis
Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis UCT Product Numbers: CSDAU26: 2mg / 6mL SPE cartridge SLDA1ID21-3UM:
More informationPesticide Analysis by Mass Spectrometry
Pesticide Analysis by Mass Spectrometry Purpose: The purpose of this assignment is to introduce concepts of mass spectrometry (MS) as they pertain to the qualitative and quantitative analysis of organochlorine
More informationBasics of SPE Technology & Mechanisms. Pieter Grobler, Sigma-Aldrich RSA
Basics of SPE Technology & Mechanisms Pieter Grobler, Sigma-Aldrich RSA Agenda The Importance of Sample Prep Overview of SPE Technology SPE Strategies Understanding Retention Mechanisms Analytical Chromatography
More information