Download "3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence"

Transcription

1 3M Purification Inc. 3M Air Management s for Your Commercial HVAC Needs Create an Air of Confidence

2 Pursuing Innovation 3M Company has long encouraged employees to pursue ideas and concepts that might, at first, seem unusual or odd to some people. From those efforts, many innovations were born. In the late 1930s, one of 3M s scientists Al Boese began a journey to develop an inexpensive, noncorrosive backing that was fibrous, but not woven, for electrical tape. The journey took him through a decade of learning and experimentation that did not produce a better backing for electrical tape, but did lead to an amazing series of products using the new technology. Al Boese retired in the 1980s, however, the journey he started continues today: 3M is still finding new ways to refine and apply the nonwoven materials. Making the Connection One of the most successful uses of the 3M non-woven technology is the 3M personal respirator. The challenge for the product design is to protect individuals, while also allowing maximum comfort and breathability. The innovation required to do this was years of R&D research, resulting in a fundamental base for 3M HVAC air filters. It was the same principle, stop unwanted particles but maximizing airflow. Breathable Filtration Today, 3M is arguably considered the world s leading expert on breathable synthetic-based filtration products. For 3M HVAC air filters, this means filtration with best in class pressure drops and lightweight media, analogous to the design criteria for personal respirators. Technological Innovation Journey 1940s 1950s 1960s 1970s 1980s 1990s 2000s 2010s First 3M Nonwoven s Introduced Meltblown Webs Personal Respirators Surgical Masks Furnace Filters Cabin Air Filters First HVAC Mini-pleated Filters HVAC V-Bank Filters

3 Our Story Building managers and HVAC engineers often face a fine balance of finding the best air filter solution for the building and keeping their operating budgets in check. Meeting environmental requirements for buildings is becoming increasingly important too. Energy consumption related to HVAC systems is a significant component of the overall energy consumption required to operate a building. Using energy efficient air handlers is one step towards reducing those operational costs. Choosing the right HVAC replacement filters helps maximize those savings opportunities. The greater the ability of a filter to load with debris without substantial increase in pressure drop, the greater the possible energy savings. HVAC engineers typically look for filters that have a low initial pressure drop, high filter loading capacity and the minimum required particle capture efficiency required. Filtration requirements, time constraints, energy, and sustainability efforts create a number of decisions that have to be researched and analyzed. Using HVAC filter and air handling unit performance data, 3M can help managers look for opportunities for improvement in associated Total Cost of Ownership (TCO). Focusing on opportunities to lower energy consumption, reduce filter maintenance time and reduce waste stream volume, have provided favorable results. Total Cost of Ownership There are five components of the ownership and operating cost of HVAC filters: the cost to purchase the filters, the cost of the associated energy use, the cost of labor for installation and replacement, the cost of disposal, and the cost of shipping. Using 3M Commercial HVAC Filters may have a positive impact on the ownership and operating cost as a result of their low pressure drop and their design for long filter life. The Total Cost of Ownership tool from 3M, for commercial HVAC air filtration systems, can be utilized to compare 3M Commercial HVAC Filters with alternative filter options. 3M offers complimentary filter evaluation services to help in your decision-making.

4 V-Bank Filters MERV A15 MERV A14 MERV A13 Industry leading low pressure drop Long filter life Factory installed gaskets for consistent reduction of air bypass Lightweight frame construction for easy handling and installation 3M Commercial HVAC V-Bank Filters MERV A13, MERV A14 and MERV A15 offer a unique combination of performance and design features including integral gaskets and nested pleat packs. These filters are an excellent choice for building owners and facility managers looking to reduce their energy utilization and minimize their total cost of operation, while still providing building occupants with high quality filtered air. Using 3M technologies, these commercial HVAC filters offer an industry leading combination of low pressure drop, robust efficiency, longevity, low weight as well as unique design features. These design features include nested pleats for reduced pressure drop and highly engineered media with a precise balance of mechanical and electret characteristics. The robust efficiency of these filters is tested to the rigorous industry filter conditioning standard ASHRAE 52.2: 2007 Appendix J. 3M V-Bank Filters are the only HVAC V-Bank filters that feature innovative integral gaskets. No other manufacturer offers this feature, which helps prevent unfiltered air from flowing past gaps between the filter and the filter rack. The integral gaskets from 3M are factory installed, which not only save time during installation, but ensure that gaskets will be used. Integral gaskets reduce air bypass, keeping coils clean Nested pleats for reduced pressure drop Innovative, open filtration media structure Key benefits Potential for reduction in electrical energy consumption due to industry leading low initial pressure drop. Filters with MERV 13 and greater ratings contribute to earning a point in the LEED certification process for new and existing buildings when used on all outside air intakes and inside air recirculation returns. Filters with MERV A13 and A14 ratings meet the Facilities Guidelines Institutes (ANSI / ASHRAE / ASHE Standard ) requirements for hospitals and healthcare facilities where MERV 13 or 14 primary filters are required. Long filter life, due to the unique combination of electret, depth-loading filtration media, the precision pleat structure and high filter media area. Factory installed gaskets ensure correct installation and usage, resulting in consistent reduction of air bypass, as well as eliminating the need for additional labor to install gaskets on-site. Due to their lightweight frame construction, 3M V-Bank Filters are easier to handle, transport, and install than many comparable V-Bank filters and metal box filters. Lighter weight is especially important when HVAC filters must be manually carried to the air handler. 3M V-Bank Filters are 100% synthetic, resulting in moisture and humidity resistant, corrosion free filters that do not support mold growth. 3M V-Bank Filters are 100% metal free and fully incinerable. 3M V-Bank Filters meet UL 900 flammability rating (US) and UL 900 Class 2 flammability rating (Canada). Reverse Flow options are also available.

5 MERV A15 MERV A15 Performance Data 492 fpm (1968 cfm for 24 x 24 filter) Initial pressure drop 0.26 w.g. Recommended final pressure drop 1.5 w.g. Efficiency Rating per ASHRAE 52.2: 2007 MERV 16 1 Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A15 Dust Holding Capacity at 1.5 w.g. 215 g Initial Resistance vs Air Velocity Minimum Filter Efficiency vs. Particle Size at 492 fpm Resistance (inches of water) Initial Filter Resistance Flow Rate (fpm) KCl Efficiency (%) Filter Efficiency vs. Particle Size at 492 fpm per ASHRAE Appendix J Particle Size (microns) Average Initial Pressure Drop is 0.26 inches of 492 fpm MERV A14 MERV A14 Performance Data 492 fpm (1968 cfm for 24 x 24 filter) Initial pressure drop 0.23 w.g. Recommended final pressure drop 1.5 w.g. Efficiency Rating per ASHRAE 52.2: 2007 MERV 15 1 Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A14 Dust Holding Capacity at 1.5 w.g. 235 g Initial Resistance vs Air Velocity Minimum Filter Efficiency vs. Particle Size at 492 fpm Resistance (inches of water) Initial Filter Resistance Flow Rate (fpm) KCl Efficiency (%) Filter Efficiency vs. Particle Size at 492 fpm per ASHRAE Appendix J Particle Size (microns) Average Initial Pressure Drop is 0.23 inches of 492 fpm

6 MERV A13 MERV A13 Performance Data Initial pressure drop Recommended final pressure drop 492 fpm (1968 cfm for 24 x 24 filter) 0.21 w.g. 1.5 w.g. Efficiency Rating per ASHRAE 52.2: 2007 MERV 14 1 Efficiency Rating per ASHRAE 52.2: 2007 Appendix J Dust Holding Capacity at 1.5 w.g. MERV A g Important use restriction: This filter must not be used as a primary filter in hospitals and healthcare facilities where a MERV 14 primary filter is required per ASHRAE M recommends the use of 3M Commercial HVAC Filter s with a minimum rating of MERV A14. Resistance (inches of water). Initial Resistance vs Air Velocity Minimum Filter Efficiency vs. Particle Size at 492 fpm Initial Filter Resistance Flow Rate (fpm) Average Initial Pressure Drop is 0.21 inches of 492 fpm KCl Efficiency (%) Filter Efficiency vs. Particle Size at 492 fpm per ASHRAE Appendix J Particle Size (microns) B Filter Measurements A C MERV A15 (MERV 16 Efficiency Rating per ASHRAE ) Standard Flow Reverse Flow Nominal Dimensions "A" x "B" x "C" Width "A" Width "B" Width "C" E E x 24 x 12 (610 x 610 x 305) 23 3/8 (594) 23 3/8 (594) 11.9 (302) E E x 24 x 12 (508 x 610 x 305) 23 3/8 (594) 19 3/8 (492) 11.9 (302) E E x 24 x 12 (305 x 610 x 305) 23 3/8 (594) 11 3/8 (289) 11.9 (302) MERV A14 (MERV 15 Efficiency Rating per ASHRAE ) Standard Flow Reverse Flow Nominal Dimensions "A" x "B" x "C" Width "A" Width "B" Width "C" E E x 24 x 12 (610 x 610 x 305) 23 3/8 (594) 23 3/8 (594) 11.9 (302) E E x 24 x 12 (508 x 610 x 305) 23 3/8 (594) 19 3/8 (492) 11.9 (302) E E x 24 x 12 (305 x 610 x 305) 23 3/8 (594) 11 3/8 (289) 11.9 (302) MERV A13 (MERV 14 Efficiency Rating per ASHRAE ) Standard Flow Reverse Flow Nominal Dimensions "A" x "B" x "C" Width "A" Width "B" Width "C" E E x 24 x 12 (610 x 610 x 305) 23 3/8 (594) 23 3/8 (594) 11.9 (302) E E x 24 x 12 (508 x 610 x 305) 23 3/8 (594) 19 3/8 (492) 11.9 (302) E E x 24 x 12 (305 x 610 x 305) 23 3/8 (594) 11 3/8 (289) 11.9 (302)

7 Mini-pleat Filters with Gasket 3M Mini-Pleat Filters with Gasket combine effective filtration performance with low airflow resistance and long filter life, which can lead to lower energy consumption as well as reduced waste disposal volume and labor cost. Our customers value the filters properties that lead to time and money savings and help them keep their operating and maintenance budgets in line. Low pressure drop for potential energy savings Long filter life Factory installed gaskets for consistent reduction of air bypass Simple, hassle-free installation without clips Integral gaskets prevent air bypass, keeping coils clean Glue beads maintain pleat spacing integrity Key benefits Significant energy savings possible when installed in place of standard filters due to low pressure drop achieved through the use of our highly refined electrostatically charged media (electret media), open filtration media structure and high surface area mini-pleat design. Longer filter life than competitive products due to the unique combination of depth loading filtration media, precise pleat structure and high filter media area. Mini-Pleat Filters with Gasket allow for simple upgrade of in-place filters, without additional capital expenditures. Minimized air bypass around and between filters, common in damaged or misaligned air handling racks, due to innovative filter frame with integrated gaskets. Reduced labor hours due to simple, hassle-free installation, supported by the innovative slip-rib frame design due to longer filter life which results in fewer filter change-outs factory installed integral gaskets, which eliminate labor required to install and properly align gaskets on site as no clips are required when installing 3M Mini-Pleat with gasket filters Far less storage space required compared to many filters of same efficiency resulting from the high performance 2 mini-pleat filter format. Significant energy value and low ash content resulting from 100% incinerable components of the filter and resistant to moisture and common chemicals. Tough filter construction resulting in low chance of filter damage during handling, installation and resistant to moisture amd common chemicals. Reliable performance in the most extreme commercial office building HVAC environments due to durable, moisture and humidity resistant, 100% synthetic filtration media, 100% metal free filter design and engineered frame construction. Superior product quality with consistent performance via rigorous ISO certified manufacturing process, a full on-site HVAC laboratory testing facility and field testing capability. Available in MERV A8, MERV A11, MERV A12 and MERV A13, 3M Mini-Pleat Filters with Gasket are an excellent choice as either primary or as pre-filters in a variety of applications. The 3M Commercial HVAC Filter MERV A8, MERV A11 and MERV A12 contribute to earning a point in the LEED certification process during the construction phase for new buildings and renovations. The 3M Commercial HVAC Filter MERV A13 Mini-Pleat with Gasket contributes to earning a point in the LEED certification process for existing and new buildings by using the filter on all outside air intakes and inside air recirculation returns. No clips are required when installing

8 MERV A13 Contributes to earning one point towards LEED certification process MERV A13 Performance Data 492 fpm (1968 cfm for 24" x 24" filter) Initial Pressure Drop 0.39" w.g. Recommended Final Pressure Drop 1.4" w.g. Efficiency Rating per ASHRAE 52.2: 2007 MERV 14¹ Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A13 Dust Holding Capacity at 1.4" w.g. 95 ± 7 g I KCl Efficiency (%) Filter Measurements A Minimum Filter Efficiency vs. Particle Size at 492 fpm Particle Size (microns) B C Appendix J Initial Resistance (inches of water) Initial Pressure Drop vs. Air Velocity 24" x 24" Filter fpm Nominal Dimensions A x B x C Average Initial Pressure Drop is 0.39 w.g. Width A Height B Depth C E x 10 x 2 (254 x 254 x 51) 9 3/8 (238) 9 3/8 (238) 1 7/8 (48) E x 20 x 2 (254 x 508 x 51) 9 3/8 (238) 19 3/8 (492) 1 7/8 (48) E x 20 x 2 (305 x 508 x 51) 11 3/8 (289) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (305 x 610 x 51) 11 3/8 (289) 23 3/8 (594) 1 7/8 (48) E x 20 x 2 (356 x 508 x 51) 13 3/8 (340) 19 3/8 (492) 1 7/8 (48) E x 25 x 2 (356 x 635 x 51) 13 3/8 (340) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (381 x 508 x 51) 14 3/8 (365) 19 3/8 (492) 1 7/8 (48) E x 16 x 2 (406 x 406 x 51) 15 3/8 (391) 15 3/8 (391) 1 7/8 (48) E x 20 x 2 (406 x 508 x 51) 15 3/8 (391) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (406 x 610 x 51) 15 3/8 (391) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (406 x 635 x 51) 15 3/8 (391) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (457 x 508 x 51) 17 3/8 (441) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (457 x 610 x 51) 17 3/8 (441) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (457 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (508 x 508 x 51) 19 3/8 (492) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (508 x 610 x 51) 19 3/8 (492) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (508 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48) E x 30 x 2 (508 x 762 x 51) 19 3/8 (492) 29 3/8 (746) 1 7/8 (48) E x 24 x 2 (610 x 610 x 51) 23 3/8 (594) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (635 x 635 x 51) 24 3/8 (619) 24 3/8 (619) 1 7/8 (48) 1 The particle capture efficiency will reduce in actual use. Please visit for more information.

9 MERV A12 MERV A12 Performance Data 492 fpm (1968 cfm for 24" x 24" filter) Initial Pressure Drop 0.37" w.g. Recommended Final Pressure Drop 1.4" w.g. Efficiency Rating per ASHRAE 52.2: 2007 MERV 14¹ Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A12 Dust Holding Capacity at 1.4" w.g. 93 ± 21 g KCl Efficiency (%) Minimum Filter Efficiency vs. Particle Size at 492 fpm Per ASHRAE Per ASHRAE-2007 Appendix J Particle Size (microns) Initial Pressure Drop (inches of water) Initial Pressure Drop vs. Air Velocity 24" x 24" Filter fpm Average Initial Pressure Drop is 0.37 w.g. Filter Measurements A B C Nominal Dimensions A x B x C Width A Height B Depth C E x 10 x 2 (254 x 254 x 51) 9 3/8 (238) 9 3/8 (238) 1 7/8 (48) E x 20 x 2 (254 x 508 x 51) 9 3/8 (238) 19 3/8 (492) 1 7/8 (48) E x 20 x 2 (305 x 508 x 51) 11 3/8 (289) 19 3/8 (492) 1 7/8 (48) F x 24 x 2 (305 x 610 x 51) 11 3/8 (289) 23 3/8 (594) 1 7/8 (48) E x 20 x 2 (356 x 508 x 51) 13 3/8 (340) 19 3/8 (492) 1 7/8 (48) E x 25 x 2 (356 x 635 x 51) 13 3/8 (340) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (381 x 508 x 51) 14 3/8 (365) 19 3/8 (492) 1 7/8 (48) E x 16 x 2 (406 x 406 x 51) 15 3/8 (391) 15 3/8 (391) 1 7/8 (48) F x 20 x 2 (406 x 508 x 51) 15 3/8 (391) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (406 x 610 x 51) 15 3/8 (391) 23 3/8 (594) 1 7/8 (48) F x 25 x 2 (406 x 635 x 51) 15 3/8 (391) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (457 x 508 x 51) 17 3/8 (441) 19 3/8 (492) 1 7/8 (48) F x 24 x 2 (457 x 610 x 51) 17 3/8 (441) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (457 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48) F x 20 x 2 (508 x 508 x 51) 19 3/8 (492) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (508 x 610 x 51) 19 3/8 (492) 23 3/8 (594) 1 7/8 (48) F x 25 x 2 (508 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48) E x 30 x 2 (508 x 762 x 51) 19 3/8 (492) 29 3/8 (746) 1 7/8 (48) F x 24 x 2 (610 x 610 x 51) 23 3/8 (594) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (635 x 635 x 51) 24 3/8 (619) 24 3/8 (619) 1 7/8 (48)

10 1 MERV A11 MERV A11 Performance Data 492 fpm (1968 cfm for 24" x 24" filter) Initial Pressure Drop 0.25" w.g. Recommended Final Pressure Drop 1.4" w.g. Efficiency Rating per ASHRAE 52.2: 2007 MERV 12¹ Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A11 Dust Holding Capacity at 1.4" w.g. 110 ± 17 g KCl Efficiency (%) Minimum Filter Efficiency vs. Particle Size at 492 fpm Appendix J Particle Size (microns) Initial Pressure Drop (inches of water) Initial Pressure Drop vs. Air Velocity 24" x 24" Filter Flow Rate (fpm) Average Initial Pressure Drop is 0.25 inches w.g. Filter Measurements A B C Nominal Dimensions A x B x C Width A Height B Depth C E x 10 x 2 (254 x 254 x 51) 9 3/8 (238) 9 3/8 (238) 1 7/8 (48) E x 20 x 2 (254 x 508 x 51) 9 3/8 (238) 19 3/8 (492) 1 7/8 (48) E x 20 x 2 (305 x 508 x 51) 11 3/8 (289) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (305 x 610 x 51) 11 3/8 (289) 23 3/8 (594) 1 7/8 (48) E x 20 x 2 (356 x 508 x 51) 13 3/8 (340) 19 3/8 (492) 1 7/8 (48) E x 25 x 2 (356 x 635 x 51) 13 3/8 (340) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (381 x 508 x 51) 14 3/8 (365) 19 3/8 (492) 1 7/8 (48) E x 16 x 2 (406 x 406 x 51) 15 3/8 (391) 15 3/8 (391) 1 7/8 (48) E x 20 x 2 (406 x 508 x 51) 15 3/8 (391) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (406 x 610 x 51) 15 3/8 (391) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (406 x 635 x 51) 15 3/8 (391) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (457 x 508 x 51) 17 3/8 (441) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (457 x 610 x 51) 17 3/8 (441) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (457 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (508 x 508 x 51) 19 3/8 (492) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (508 x 610 x 51) 19 3/8 (492) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (508 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48) E x 30 x 2 (508 x 762 x 51) 19 3/8 (492) 29 3/8 (746) 1 7/8 (48) E x 24 x 2 (610 x 610 x 51) 23 3/8 (594) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (635 x 635 x 51) 24 3/8 (619) 24 3/8 (619) 1 7/8 (48) The particle capture efficiency will reduce in actual use. Please visit for more information.

11 MERV A8 MERV A8 Performance Data 492 fpm (1968 cfm for 24" x 24" filter) Initial Pressure Drop 0.26" w.g. Recommended Final Pressure Drop 1.4" w.g. Efficiency Rating per ASHRAE 52.2: 2007 MERV 11¹ Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A8 Dust Holding Capacity at 1.4" w.g. 90 ± 15 g KCl Efficiency (%) Filter Measurements A Minimum Filter Efficiency vs. Particle Size at 492 fpm Appendix J Particle Size (microns) fpm Average Initial Pressure Drop is 0.26 w.g. B C Initial Pressure Drop (inches of water) Nominal Dimensions A x B x C Initial Pressure Drop vs. Air Velocity 24" x 24" Filter Width A Height B Depth C E x 10 x 2 (254 x 254 x 51) 9 3/8 (238) 9 3/8 (238) 1 7/8 (48) E x 20 x 2 (254 x 508 x 51) 9 3/8 (238) 19 3/8 (492) 1 7/8 (48) E x 20 x 2 (305 x 508 x 51) 11 3/8 (289) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (305 x 610 x 51) 11 3/8 (289) 23 3/8 (594) 1 7/8 (48) E x 20 x 2 (356 x 508 x 51) 13 3/8 (340) 19 3/8 (492) 1 7/8 (48) E x 25 x 2 (356 x 635 x 51) 13 3/8 (340) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (381 x 508 x 51) 14 3/8 (365) 19 3/8 (492) 1 7/8 (48) E x 16 x 2 (406 x 406 x 51) 15 3/8 (391) 15 3/8 (391) 1 7/8 (48) E x 20 x 2 (406 x 508 x 51) 15 3/8 (391) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (406 x 610 x 51) 15 3/8 (391) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (406 x 635 x 51) 15 3/8 (391) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (457 x 508 x 51) 17 3/8 (441) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (457 x 610 x 51) 17 3/8 (441) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (457 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (508 x 508 x 51) 19 3/8 (492) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (508 x 610 x 51) 19 3/8 (492) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (508 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48) E x 30 x 2 (508 x 762 x 51) 19 3/8 (492) 29 3/8 (746) 1 7/8 (48) E x 24 x 2 (610 x 610 x 51) 23 3/8 (594) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (635 x 635 x 51) 24 3/8 (619) 24 3/8 (619) 1 7/8 (48)

12 Mini-Pleat Filters, No Gasket 3M Commercial HVAC Filter MERV A8 and A12 Mini-Pleat Filters without Gaskets combine excellent filtration performance with low airflow resistance and long filter life in a cost effective construction. Their balance of properties may offer building owners and managers time and money savings. Low pressure drop for potential energy savings Long filter life Tough filter and frame construction resulting in low chance of filter damage during handling, installation or use in humid environments Key benefits Increased air flow or lower fan energy consumption compared to equivalent filter design and efficiency of competitors Electrostatically charged, open construction media Durable synthetic media and frame construction Long filter life Media loads through the depth of the filter Mini-pleat construction provides high surface area Small Package Size Easy to handle, low disposal volume, low shipping costs Demonstrated filtration efficiency Lightweight, rigid frame 100% Synthetic media-filters are very durable: Less chance of filter damage during handling and installation Resistant to moisture and common chemicals Resistant to fiber shedding

13 MERV A12 Initial Resistance (inches of water) Initial Resistance vs. Air Velocity MERV A12 Performance Data Initial Resistance Flow Rate (fpm) Recommended Final Resistance Efficiency Rating per ASHRAE 52.2: 2007 MERV 14 1 Efficiency Rating per ASHRAE 52.2: 2007 Appendix J 492 fpm (1968 cfm for 24 x 24 filter) 0.37 inches of water 1.4 inches of water MERV A12 Average Dust Holding Capacity at 1.4 inches of water 93±21g Resistance (inches of water) Resistance vs. Dust 492 fpm ASHRAE Dust Fed (g) Filter Measurements A B C Stock Nominal Dimensions Width A Height B Depth C E x 10 x 2 (254 x 254 x 51) 9 3/8 (238) 9 3/8 (238) 1 7/8 (48) E x 20 x 2 (254 x 508 x 51) 9 3/8 (238) 19 3/8 (492) 1 7/8 (48) E x 20 x 2 (305 x 508 x 51) 11 3/8 (289) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (305 x 610 x 51) 11 3/8 (289) 23 3/8 (594) 1 7/8 (48) E x 20 x 2 (356 x 508 x 51) 13 3/8 (340) 19 3/8 (492) 1 7/8 (48) E x 25 x 2 (356 x 635 x 51) 13 3/8 (340) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (381 x 508 x 51) 14 3/8 (365) 19 3/8 (492) 1 7/8 (48) E x 16 x 2 (406 x 406 x 51) 15 3/8 (391) 15 3/8 (391) 1 7/8 (48) E x 20 x 2 (406 x 508 x 51) 15 3/8 (391) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (406 x 610 x 51) 15 3/8 (391) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (406 x 635 x 51) 15 3/8 (391) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (457 x 508 x 51) 17 3/8 (441) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (457 x 610 x 51) 17 3/8 (441) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (457 x 634 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (508 x 508 x 51) 19 3/8 (492) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (508 x 610 x 51) 19 3/8 (492) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (508 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48) E x 30 x 2 (508 x 762 x 51) 19 3/8 (492) 29 3/8 (746) 1 7/8 (48) E x 24 x 2 (610 x 610 x 51) 23 3/8 (594) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (635 x 635 x 51) 24 3/8 (619) 24 3/8 (619) 1 7/8 (48)

14 MERV A8 Resistance (inches of water) Initial Resistance vs. Air Velocity MERV A8 Performance Data Initial Resistance Recommended Final Resistance Flow Rate (fpm) Efficiency Rating per ASHRAE 52.2: 2007 MERV 11 1 Efficiency Rating per ASHRAE 52.2: 2007 Appendix J 492 fpm (1968 cfm for 24 x 24 filter) 0.26±0.01 inches of water 1.4 inches of water MERV A8 Average Dust Holding Capacity at 1.4 inches of water 90±15g Resistance (inches of water) Resistance vs. Dust 492 fpm ASHRAE Dust Fed (g) Filter Measurements A B C Stock Nominal Dimensions Width A Height B Depth C E x 10 x 2 (254 x 254 x 51) 9 3/8 (238) 9 3/8 (238) 1 7/8 (48) E x 20 x 2 (254 x 508 x 51) 9 3/8 (238) 19 3/8 (492) 1 7/8 (48) E x 20 x 2 (305 x 508 x 51) 11 3/8 (289) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (305 x 610 x 51) 11 3/8 (289) 23 3/8 (594) 1 7/8 (48) E x 20 x 2 (356 x 508 x 51) 13 3/8 (340) 19 3/8 (492) 1 7/8 (48) E x 25 x 2 (356 x 635 x 51) 13 3/8 (340) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (381 x 508 x 51) 14 3/8 (365) 19 3/8 (492) 1 7/8 (48) E x 16 x 2 (406 x 406 x 51) 15 3/8 (391) 15 3/8 (391) 1 7/8 (48) E x 20 x 2 (406 x 508 x 51) 15 3/8 (391) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (406 x 610 x 51) 15 3/8 (391) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (406 x 635 x 51) 15 3/8 (391) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (457 x 508 x 51) 17 3/8 (441) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (457 x 610 x 51) 17 3/8 (441) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (457 x 634 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48) E x 20 x 2 (508 x 508 x 51) 19 3/8 (492) 19 3/8 (492) 1 7/8 (48) E x 24 x 2 (508 x 610 x 51) 19 3/8 (492) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (508 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48) E x 30 x 2 (508 x 762 x 51) 19 3/8 (492) 29 3/8 (746) 1 7/8 (48) E x 24 x 2 (610 x 610 x 51) 23 3/8 (594) 23 3/8 (594) 1 7/8 (48) E x 25 x 2 (635 x 635 x 51) 24 3/8 (619) 24 3/8 (619) 1 7/8 (48)

15 High Air Flow (HAF) Filters Microstructured Features Airflow The open channel construction of 3M HAF filters offers low initial airflow resistance, while its unique microstructure and electrostatic charge provides effective particle capture and retention. In certain applications, this may translate into fewer filter changeouts, reduced coil cleaning, and reduced maintenance costs. A balanced approach to improved air filtration 3M HAF Air Filters may offer an ideal alternative in applications where regular filter replacement is difficult or impractical, but where low airflow resistance is important. Developed using innovative 3M technologies, 3M HAF Air Filters are frameless, selfsupporting, and are constructed from an array of open flow channels. These filters are electrostatically charged for enhanced particle capture and retention. 3M HAF Air Filters are available with an antimicrobial agent to help inhibit the growth of mold and mildew on the filter media. Users should be aware that mold and mildew may grow on captured particles that build up over time on the filter. Physical characteristics Open channel structure Microstructured, electrostatically charged media (refer to Performance Data on next page) 100% synthetic media Self-supporting filter Standard: White Antimicrobial: Green Filter Measurements Height A max Length B max Available Thicknesses C C (700) (1200) 0.20, 0.39, 0.59, 0.79, 0.98, 1.18 (5, 10, 15, 20, 25, 30) A B

16 Additional Information For questions or to place an order in the U.S., contact your local 3M Purification Inc. distributor or 3M Purification Inc. Customer Service at (800) or (651) IMPORTANT NOTICE: The information in this literature is based on tests 3M believes are reliable. It is not and should not be relied on as a product or technical specification. We do not guarantee the accuracy of this information. If any products described in this literature are defective, 3M will replace them at no charge. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES FOR THESE PRODUCTS, INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. You are responsible for determining whether products described in this literature are fit for a particular purpose and suitable for your application. Because there are many factors within your knowledge and control that might affect the use and performance of these products, you must evaluate these products to determine whether they are fit for a particular purpose, are suitable for your application, and meet your performance expectations. 3M IS NOT LIABLE FOR ANY LOSS OR DAMAGES, WHETHER DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL ARISING OUT OF THE USE OF OR INABILITY TO USE ANY OF THESE PRODUCTS. CAUTION: USED FILTERS MAY CONTAIN CONTAMINANTS FROM OPERATION OF THE HVAC SYSTEM. FOR PROPER HANDLING OF USED FILTERS, CONSULT APPLICABLE HEALTH AND SAFETY STANDARDS OR CONTACT AN INDUSTRIAL HYGIENIST. TO REDUCE RISK OF ILLNESS OR INJURY, ALWAYS USE APPROPRIATE RESPIRATORY PROTECTION AND PROTECTIVE CLOTHING WHEN REMOVING OR HANDLING USED FILTERS. DISPOSE OF USED FILTERS ONLY IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL LAWS AND REGULATIONS. IMPORTANT USE RESTRICTIONS: DO NOT EXPOSE THIS FILTER DIRECTLY TO UV RADIATION FROM A UV PURIFICATION SYSTEM. EXCESSIVE UV EXPOSURE MAY LEAD TO A REDUCTION IN THE MECHANICAL INTEGRITY AND PERFORMANCE OF THE FILTER. THIS FILTER MUST NOT BE USED FOR THE FOLLOWING UNAUTHORIZED USES: A) ASBESTOS, LEAD OR MOLD REMEDIATION; B) BIOTERRORISM PROTECTION; C) APPLICATIONS IN BUILDINGS THAT REQUIRE OR ARE UNDERGOING AIR HANDLING SYSTEM REMEDIATION OF HAZARDOUS SUBSTANCES; OR (D) PROTECTIVE ENVIRONMENTS PER AIA GUIDELINES. 3M Purification Inc. 400 Research Parkway Meriden, CT U.S.A. (800) (651) M is a trademark of 3M Company. LEED is a trademark of the U.S. Green Building Council M Company. All rights reserved. Please recycle. Printed in U.S.A REV 0514 Your Local Distributor:

Total Cost of Ownership Tool from 3M

Total Cost of Ownership Tool from 3M Commercial HVAC Filters Total Cost of Ownership Tool from 3M Restricted budgets challenge facility owners and operators to seek solutions that help save energy and reduce operating costs, while maintaining

More information

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS DATA CENTERS Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS COSTLY FAN ENERGY REDUCED BY CAMFIL PREMIUM PRODUCTS = COST SAVINGS Power Usage Effectiveness (PUE) is an important metric

More information

Technical Brief. 3M Commercial HVAC Filters. Commercial HVAC Filter Efficiency Reporting Value. Abstract. Introduction

Technical Brief. 3M Commercial HVAC Filters. Commercial HVAC Filter Efficiency Reporting Value. Abstract. Introduction 3M Commercial HVAC Filters Technical Brief Commercial HVAC Filter Efficiency Reporting Value Abstract The effi ciency of fi lters utilized in the HVAC industry is characterized by the Minimum Effi ciency

More information

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment. SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel

More information

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade Robert McCabe Director, Health Care Solutions HTS Chicago Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade Biography Robert McCabe has been involved in commercial

More information

G U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice

G U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice G U National Air Filtration Association Recommended Practice I D E L I N E Procurement Guideline TRAINING EDUCATION CERTIFICATION HVAC Air Filter Purchasing Specification Guideline 1.0 Purpose To provide

More information

MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard

MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard Advances in testing procedures, coupled with greater pressure for better IAQ, leads to a new standard By Ron Wilkinson, P.E.

More information

Quick wins for energy savings in buildings

Quick wins for energy savings in buildings Quick wins for energy savings in buildings Choosing low energy air filters for both optimized energy performance and indoor air quality Executive Summary HVAC systems heat, cool and clean the air within

More information

How to Choose An Air Filter For Your Boat

How to Choose An Air Filter For Your Boat How to Choose An Air Filter For Your Boat That Will Reduce Diesel Fumes, Smoke and Odors L-2395 Rev. 1-07-06 Air Filtration Fundamentals Air filters are devices that capture dust and other contaminants

More information

HVAC - PANEL AIR FILTERS

HVAC - PANEL AIR FILTERS Fiberglass MERV 1-4 Disposable Air Filter HVAC - PANEL AIR FILTERS The F312 disposable panel filters are designed to withstand the demands of tough industrial and commercial applications. Purolator assures

More information

Gridstone Gypsum Ceiling Panels

Gridstone Gypsum Ceiling Panels Gold Bond brand 09 29 00/NGC Gridstone Gypsum Ceiling Panels Helping You Build Better With High-Quality Products And Resources Founded in 1925, National Gypsum is one of the world s largest producers of

More information

Laminar Flow Cabinets

Laminar Flow Cabinets Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical

More information

HVAC - PANEL AIR FILTERS

HVAC - PANEL AIR FILTERS Fiberglass MERV 1-4 Disposable Air Filter HVAC - PANEL AIR FILTERS The F312 disposable panel filters are designed to withstand the demands of tough industrial and commercial applications. Purolator assures

More information

How To Install A Perfect 16 Id Series Filter System

How To Install A Perfect 16 Id Series Filter System IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System Perfect 16 Installation Manual Product Data High-Performance Medical-Grade Residential/Commercial Air Filtration System Application The

More information

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference. User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.

More information

10 YEAR WARRANTY REGISTRATION PROCEDURES. Please see product warranty section in back of book for registration procedures

10 YEAR WARRANTY REGISTRATION PROCEDURES. Please see product warranty section in back of book for registration procedures 10 YEAR WARRANTY REGISTRATION PROCEDURES Please see product warranty section in back of book for registration procedures Carrier Systems are eligible for 10 YEAR Warranty Coverage when registered! Important

More information

CUNO TM Series NB Bags for Liquid Filtration

CUNO TM Series NB Bags for Liquid Filtration CUNO TM Series NB Bags for Liquid Filtration Customers have relied on CUNO to provide quality filtration solutions for the most demanding applications. Leveraging 3M innovation, CUNO has applied this expertise

More information

Industrial Attachment Tapes X-Series. Value, Performance. & Quality. Simply X.

Industrial Attachment Tapes X-Series. Value, Performance. & Quality. Simply X. 3M Industrial Attachment Tapes X- Value, Performance & Quality Simply X. 3M has made it easy to select a high-quality tape for my attachment and assembly needs. Simply X. Your application. OUR TAPE. We

More information

Double Coated Urethane Foam Tapes

Double Coated Urethane Foam Tapes 3 Double Coated Urethane Foam Tapes 4004 4008 4016 4026 4032 4052 4056 4085 Technical Data April, 2009 Product Description 3M Double Coated Urethane Foam Tapes are conformable foams that offer high shear

More information

Mechanical Rooftop Custom Capabilities

Mechanical Rooftop Custom Capabilities Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition

More information

plenum slot diffusers

plenum slot diffusers light powered Redefine your comfort zone. www.titus-hvac.com dual-function smart logic light powered energy solutions Table of Contents PLENUM SLOT IFFUSERS products Plenum Slot iffusers Products... 4

More information

Downflo workstation DuSt ColleCtorS

Downflo workstation DuSt ColleCtorS Downflo WorkStation Dust Collectors Outperforms All Other Collectors Downflo WorkStations (DWS) fit anywhere on the plant floor and apply NO restrictions to worker movements or visibility. The full line

More information

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION: Revision Level: 01 Revision Date: 07/07/2011 Please read all instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Air Purifier. Failure to do

More information

NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS

NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS National Air Duct Cleaners Association 1518 K Street, N.W. Suite 503 Washington, DC 20005 (202)

More information

Crystal Clear Sealant

Crystal Clear Sealant Crystal Clear Sealant Technical Data February, 2012 Product Description 3M Crystal Clear Sealant is a one component thermoplastic elastomer which forms permanent elastic bonds when used in surface sealing

More information

3M Housings DS Series

3M Housings DS Series Lenntech info@lenntech.com Tel. +1-15-610-900 www.lenntech.com Fax. +1-15-616-89 M Housings For Filters Filter Housings, constructed of durable stainless steel, meet general-purpose industrial, chemical,

More information

Healthcare Clean Air Solutions

Healthcare Clean Air Solutions THE WORLD LEADER IN CLEAN AIR SOLUTIONS Healthcare Clean Air Solutions PARTICULATE AND GASEOUS FILTRATION BETTER AIR IS OUR BUSINESS Total Clean Air Solutions for Healthcare Facilities Around the globe,

More information

Camfil. Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality

Camfil. Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality Camfil Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality Most non-practitioners notice the HVAC system when it is too hot, or too cold, or in other ways not working

More information

How To Predict Personal Protective Equipment (Ppe)

How To Predict Personal Protective Equipment (Ppe) Personal Protective Equipment (PPE) Outlook for North American and Western European Labs and Research Facilities Focus on Research and Development to Boost Revenue, Especially in the Healthcare Sector

More information

Ultra-Filter. Compressed Air Filter. DF Series

Ultra-Filter. Compressed Air Filter. DF Series Ultra-Filter DF Series ié~çáåö=íüé=t~ó=áå=^áê=mìêáñáå~íáçå As one of the world s leading manufacturers of compressed air purification equipment, Donaldson has built a comprehensive engineering, manufacturing,

More information

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling 2 Ductless Ventilation & Fresh Air Solutions We can fill your home with healthy, fresh air Indoor Air Pollution is real, and it

More information

HotLok Pass Through Blanking Panel

HotLok Pass Through Blanking Panel HotLok Pass Through Blanking Panel Part Numbers 1U - 10112 2U - 10113 Table of Contents Tools Required for Installation Page 2 Dimensions and Rack Requirements Page 2 Installation Procedures Page 3 Removal

More information

Laminar Flow Cabinets and Workstations

Laminar Flow Cabinets and Workstations VERTICAL AND HORIZONTAL HEPA FILTERED SYSTEMS FOR PROCESS OR OPERATOR PROTECTION Laminar Flow Cabinets and Workstations For procedures requiring protection from particulate contamination and for aseptic

More information

Electrostatic or Electronic: Know the Facts By Robert P. Scaringe, P.E., Ph.D., ---President of Mainstream Engineering

Electrostatic or Electronic: Know the Facts By Robert P. Scaringe, P.E., Ph.D., ---President of Mainstream Engineering Electrostatic or Electronic: Know the Facts By Robert P. Scaringe, P.E., Ph.D., ---President of Mainstream Engineering HVAC system air filter upgrades are one way contractors can simultaneously increase

More information

Camfil Farr Technical Services Bulletin

Camfil Farr Technical Services Bulletin Camfil Farr Technical Services Bulletin ASHRAE Testing for HVAC Air Filtration A Review of Standards 52.1-1992 & 52.2-1999 The American Society of Heating, Refrigeration, and Air Conditioning Engineers

More information

IEQ-15 Air Distribution System

IEQ-15 Air Distribution System AIM OF CREDIT To encourage and recognise the design and maintenance of air distribution systems that minimise the risk of particulate and microbial contamination to the internal air supply. CREDIT CRITERIA

More information

EMI Shielding Tapes Product Selection Guide. Trusted. Performance. from the. Tape Experts

EMI Shielding Tapes Product Selection Guide. Trusted. Performance. from the. Tape Experts EMI Shielding Tapes Product Selection Guide Trusted Performance from the Tape Experts 3M EMI Shielding Tapes A wide variety of tapes for EMI shielding and grounding Copper, aluminum, and tin-plated copper

More information

Industrial Adhesives and Tapes Division 3M Center Building 225-3S-06 St. Paul, MN 55144-1000 1-800-362-3550 www.3m.com/vhb

Industrial Adhesives and Tapes Division 3M Center Building 225-3S-06 St. Paul, MN 55144-1000 1-800-362-3550 www.3m.com/vhb Limited Product Warranty: 3M warrants for 24 months from the date of manufacture, 3M VHB tapes will be free of defects in material and manufacture. 3M MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING

More information

Air Filter Selection Guide

Air Filter Selection Guide Air Filter Selection Guide It s Not Just Air, It s the Source of Life. Disposable Filters Heavy Duty Box Frame Filter - MERV 4 Spun Glass (Model # 10255) or Synthetic (11255) Media Flanders HD Industrial

More information

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to

More information

3 Single-Coated Foam Tapes

3 Single-Coated Foam Tapes 3 Single-Coated Foam Tapes Technical Data May, 2008 Product Description 3M Single-Coated Foam Tapes will adhere to a variety of substrates, including latex-painted wood, lacquered wood, enameled steel,

More information

Gas-Phase Filtration. Advanced Solutions for the Removal of Airborne Particulate and Gaseous Contaminants. Better Air is Our Business

Gas-Phase Filtration. Advanced Solutions for the Removal of Airborne Particulate and Gaseous Contaminants. Better Air is Our Business Gas-Phase Filtration Advanced Solutions for the Removal of Airborne Particulate and Gaseous Contaminants Better Air is Our Business Gas-Phase Filtration Industry Leader Our Qualifications AAF International

More information

Dehumidification Frequently Asked Questions

Dehumidification Frequently Asked Questions Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful

More information

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material Revised November 21, 2013 Application Code of Practice Where asbestos is present or believed to be present in a workplace

More information

3M Dual Lock Reclosable Fastener

3M Dual Lock Reclosable Fastener 3 Dual Lock Reclosable Fasteners SJ3550CF (Type 250) SJ3551CF(Type 400) SJ3552CF(Type 170) Dual Lock Reclosable Fastener Black with a clear acrylic adhesive Product Information February, 2007 Product Description

More information

DATA CENTRES. Camfil Farr Segment Brochure Data Centres Camfil Farr - Clean Air solutions

DATA CENTRES. Camfil Farr Segment Brochure Data Centres Camfil Farr - Clean Air solutions DATA CENTRES Camfil Farr Segment Brochure Data Centres Camfil Farr - Clean Air solutions Camfil Farr Leading the way in clean air Technology About Camfil Farr Camfil Farr is a world Leader in clean air

More information

LEED GOLD CERTIFIED OFFICE DESIGN AND CONSTRUCTION

LEED GOLD CERTIFIED OFFICE DESIGN AND CONSTRUCTION LEED GOLD CERTIFIED OFFICE DESIGN AND CONSTRUCTION Setting a Precedent for Sustainable Interior Commercial Design FLEXIBLE INNOVATIVE CREATIVE R E S P O N S I B L E We transformed our lower Manhattan office

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

Dust Filtration Catalogue

Dust Filtration Catalogue www.filterteknik.dk Dust Filtration Catalogue Pre filtration mats Glass fibre mats Pocket filters Panel filters Compact filters Cassette filters Dust filters Dust Filtration Catalogue In order to show

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

HIGH PERFORMANCE FILTERS AND ELEMENTS

HIGH PERFORMANCE FILTERS AND ELEMENTS HIGH PERFORMANCE FILTERS AND ELEMENTS FILTRATION Fil*tra*tion (fil-tra-shen) n. The act or process of filtering. What exactly is filtration and why is it an integral part of today s industries? Simply

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

Commercial Coil Cleaning:

Commercial Coil Cleaning: 18 Commercial Coil Cleaning: by Barry Harris, PH.D., ASCS 1, Lindell F. Killian, ASCS 2, and Nicolaus P. Neumann, P.E. 3 A Case History Facility managers and HVAC engineering supervisors have limited budgets

More information

XYZ Contract Company Industrial Hygiene Program

XYZ Contract Company Industrial Hygiene Program [This is an example of a general Industrial Hygiene program intended to help Industrial Hygienists in the development of a specific contractor IH program if one is not yet developed. It is not intended

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined

More information

3 Laser Toner Printable Polyester Label Material 7840TL

3 Laser Toner Printable Polyester Label Material 7840TL 3 Laser Toner Printable Polyester Label Material page 1 of 5 Technical Data February 15, 1999 Supersedes July 1, 1997 Construction (Calipers are nominal values.) Facestock Adhesive Liner 2.3 mil (58 micron)

More information

UI Procedures for Asbestos Management

UI Procedures for Asbestos Management UI Procedures for Asbestos Management The University of Iowa Rev.12/12/2012 These procedures apply to employees and contractors involving the identification, work on, removal, or repair of asbestos-containing

More information

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

General Purpose Laminar Flow Cabinets, Horizontal and Vertical 24 36 48 60 72 96 The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. VLF-48 Provides reliable protection for samples and work processes for a multitude of applications. p:2 Product

More information

Owner s Manual Model 5000 Safety, Operating and Maintenance Instructions

Owner s Manual Model 5000 Safety, Operating and Maintenance Instructions Electronic Air Cleaner 90-1147 Owner s Manual Model 5000 Safety, Operating and Maintenance Instructions READ AND SAVE THIS MANUAL WARNING 120 Volts may cause serious injury from electrical shock. Disconnect

More information

PRESENTATION BY: MIKE BURT AIR FILTER SOLUTIONS INC. DENVER, COLORADO

PRESENTATION BY: MIKE BURT AIR FILTER SOLUTIONS INC. DENVER, COLORADO PRESENTATION BY: MIKE BURT AIR FILTER SOLUTIONS INC. DENVER, COLORADO INEXPENSIVE RETROFIT DESIGNS FOR ABOVE CEILING UNITS Fan coil units Fan terminal units Single ducted fan powered units Heat pump units

More information

Trane s Position on UV-C Lights

Trane s Position on UV-C Lights Trane s Position on UV-C Lights Note: The following Trane corporate position statement was issued on October 6, 2008. Trane monitors technologies that offer the potential to improve indoor air quality

More information

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

Ductless Spray Booth Series

Ductless Spray Booth Series Sentry Air Systems, Inc. Ductless Spray Booth Series A Respiratory Safety Engineering Control: Ductless Benchtop Hooded Enclosures for the extraction and purification of aerosol spray paint fumes & particulate.

More information

Dehumidifier Users manual. For Models: DH45S DH65S

Dehumidifier Users manual. For Models: DH45S DH65S Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but

More information

G u i d e l. Schools CERTIFICATION EDUCATION TRAINING. Recommended Practice

G u i d e l. Schools CERTIFICATION EDUCATION TRAINING. Recommended Practice G u i d e l i n e s Schools Recommended Practice TRAINING EDUCATION CERTIFICATION Publication Information Why NAFA Guidelines? The National Air Filtration Association (NAFA) provides Best Practice Guidelines

More information

VAV Laboratory Room Airflow The Lowdown on Turndown

VAV Laboratory Room Airflow The Lowdown on Turndown Technology Report March, 2003 VAV Laboratory The Lowdown on Turndown Turndown comparison of these two turndown ratios. Note the small actual airflow difference between them. control ranges are normally

More information

Advantages Of A New And Advanced Nanofiber Coating Technology For Filtration Media Compared to The Electrospinning Process

Advantages Of A New And Advanced Nanofiber Coating Technology For Filtration Media Compared to The Electrospinning Process Advantages Of A New And Advanced Nanofiber Coating Technology For Filtration Media Compared to The Electrospinning Process John Wertz Immo Schnieders Abstract Research and development of nanofibers has

More information

LEED FOR BUILDING DESIGN AND CONSTRUCTION (LEED BD+C) v4 DOCUMENTATION LETTER FOR UNITED STATES OF AMERICA

LEED FOR BUILDING DESIGN AND CONSTRUCTION (LEED BD+C) v4 DOCUMENTATION LETTER FOR UNITED STATES OF AMERICA LEED FOR BUILDING DESIGN AND CONSTRUCTION (LEED BD+C) v4 DOCUMENTATION LETTER FOR UNITED STATES OF AMERICA RE: LEED Documentation of Dyson Airblade db AB14 (AB02/ AB04/ AB06 discontinued) May 30, 2014

More information

HIH-4000 Series Humidity Sensors

HIH-4000 Series Humidity Sensors HIH-4000 Series Humidity Sensors DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users. Direct input to a controller or

More information

UV100E Ultraviolet System

UV100E Ultraviolet System UV100E Ultraviolet System OWNER S GUIDE 69-1573-3 !! UV100E ULTRAVIOLET SYSTEM IMPORTANT Please read these instructions and keep them in your records. HOW YOUR ULTRAVIOLET AIR TREATMENT SYSTEM OR SURFACE

More information

Technical Data Sheet February 2014

Technical Data Sheet February 2014 Scotch-Weld Technical Data Sheet February 2014 Product Description s are high performance, two-part acrylic adhesives that offer excellent shear, peel, and impact performance. These toughened products

More information

Industrial Semi Metal USB

Industrial Semi Metal USB Industrial Semi Metal USB Generation 5L HERCULES-P Series Product Specification INDUSTRIAL Semi Metal USB Flash Disk Generation 5L Version 01V0 Document No. 100-xMUFD-MPT5L November 2014 APRO CO., LTD.

More information

Ceiling Mount Air Handler Manual

Ceiling Mount Air Handler Manual www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty

More information

Oakland Unified San Jose Unified Stanford University Santa Ana Unified Newhall Unified Clovis Unified Merced Union High School Grossmont Union High

Oakland Unified San Jose Unified Stanford University Santa Ana Unified Newhall Unified Clovis Unified Merced Union High School Grossmont Union High Oakland Unified San Jose Unified Stanford University Santa Ana Unified Newhall Unified Clovis Unified Merced Union High School Grossmont Union High School District Industry Standards Damage Assessments

More information

HVAC Design Requirements

HVAC Design Requirements Maintenance of HVAC HVAC Design Requirements Air Flow Diagram แบบ Recirculation Air Flow Diagram แบบ Once Through Definition Of Conditions As built At rest In operation air air air Maintenance GMP Requirements

More information

Installation Instructions WARNING: WARNING: WARNING: WARNING: WARNING:

Installation Instructions WARNING: WARNING: WARNING: WARNING: WARNING: Installation Instructions Ultra-Violet Air Purifier Residential/Commercial Duct Installation Applications - RX4000, RX4000B, RX1700 SAFETY CONSIDERATIONS Installation and servicing of air-conditioning

More information

DESERT RESEARCH INSTITUTE MOLD ASSESSMENT AND REMEDIATEION PROCEDURE

DESERT RESEARCH INSTITUTE MOLD ASSESSMENT AND REMEDIATEION PROCEDURE 1.0 Introduction DESERT RESEARCH INSTITUTE This Desert Research Institute (DRI) Mold Assessment and Remediation Procedure was established to assure that consistent and uniform information is provided to

More information

DIESEL FUEL CONDITIONING

DIESEL FUEL CONDITIONING COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency

More information

Specification. Indoor Air Quality Management

Specification. Indoor Air Quality Management GREENGUARD Environmental Institute 2211 Newmarket Parkway, Suite 110 Marietta, GA 30067 1.800.427.9681 Specification Indoor Air Quality Management This Master Specification section is intended for use

More information

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options. Application and esign Thermal ispersion Air Measuring Station with VC-23 Control amper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage

More information

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG Installation and Operating Manual Model F1800C Model F1800PG Model F180C Model F180PG Model F1806C Model F1806PG www.ipsystemsusa.com Contents Safety Warnings... Items supplied... Description... Installation...4

More information

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

There are several types of air cleaning devices available, each designed to remove certain types of pollutants. Please Note: EPA neither certifies nor recommends particular brands of home air cleaning devices. While some home air cleaning devices may be useful in some circumstances, EPA makes no broad endorsement

More information

Document Library TS Data Sheet 08609. 3M Windo-Weld Super Fast Urethane. Data Sheet. Public

Document Library TS Data Sheet 08609. 3M Windo-Weld Super Fast Urethane. Data Sheet. Public Document Library TS Data Sheet 08609 Public Rev:3 Effective: 09/14/2007 Status: Active 3M Windo-Weld Super Fast Urethane Data Sheet 3M Part No.(s) 3M Part Descriptor(s) 08609 3M Windo-Weld Super Fast Urethane

More information

Surface Mount Multilayer Ceramic Chip Capacitors for Automotive Applications

Surface Mount Multilayer Ceramic Chip Capacitors for Automotive Applications Surface Mount Multilayer Ceramic Chip Capacitors for Automotive Applications FEATURES AEC-Q200 qualified with PPAP available Available in 0402 to 1812 body size Three dielectric materials AgPd termination

More information

Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications

Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications ELECTRICAL SPECIFICATIONS X7R GENERAL SPECIFICATION Note Electrical characteristics at +25 C unless otherwise specified

More information

Ultra-Web High Efficiency Nanofiber Filters

Ultra-Web High Efficiency Nanofiber Filters Ultra-Web High Efficiency Nanofiber Filters Longer life, cleaner air, cost savings! The Ultra-Web advantage is cleaner air Nanofibers are scientifically proven to have an advantage in efficiency and pressure

More information

NFC Communication Tray Model: HHX-IT3-Z

NFC Communication Tray Model: HHX-IT3-Z INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8

More information

SMS7630-061: Surface Mount, 0201 Zero Bias Silicon Schottky Detector Diode

SMS7630-061: Surface Mount, 0201 Zero Bias Silicon Schottky Detector Diode DATA SHEET SMS7630-061: Surface Mount, 0201 Zero Bias Silicon Schottky Detector Diode Applications Sensitive RF and microwave detector circuits Sampling and mixer circuits High volume wireless systems

More information

Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models. Up to 17.0 SEER, Up to 12.8 EER

Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models. Up to 17.0 SEER, Up to 12.8 EER Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models Up to 17.0 SEER, Up to 12.8 EER SAVING ENERGY WITH INTELLIGENCE Designed to intelligently achieve the lowest total cost of ownership Energence

More information

Controlling Condensation On CWP Insulation BY ED LIGHT, MEMBER ASHRAE; JAMES BAILEY, P.E., MEMBER ASHRAE; AND ROGER GAY

Controlling Condensation On CWP Insulation BY ED LIGHT, MEMBER ASHRAE; JAMES BAILEY, P.E., MEMBER ASHRAE; AND ROGER GAY This article was published in ASHRAE Journal, Decemeber 2014. Copyright 2014 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without

More information

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

TABLE OF CONTENTS SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7 2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE

More information

WhisperGreen Select Ventilation Fans

WhisperGreen Select Ventilation Fans FV-05-11VKS1, FV-05-11VK1, FV-11-15VK1 FV-05-11VKSL1, FV-05-11VKL1, FV-11-15VKL1 WhisperGreen Select Ventilation Fans n Customizable, all-in-one fan and fan/led light combinations n Pick-A-Flow speed selector

More information

File: Spill Response Plan for Hazard Chemicals and Mercury Spills. Orig. Date: 12/01/2005 Review Date: January Review Date: March 2010

File: Spill Response Plan for Hazard Chemicals and Mercury Spills. Orig. Date: 12/01/2005 Review Date: January Review Date: March 2010 File: Spill Response Plan for Hazard Chemicals and Mercury Spills Orig. Date: 12/01/2005 Review Date: January Review Date: March 2010 OSHA: 1910.120 EPA: 40CFR 112.7 Messiah College Spill Response Policy

More information

Set-Up Instructions. (Liner-Based System) UL LISTED. Important Read set-up instructions before assembly. Report any shortages within 72 hours

Set-Up Instructions. (Liner-Based System) UL LISTED. Important Read set-up instructions before assembly. Report any shortages within 72 hours INDUSTRIAL POWER Set-Up Instructions (Liner-Based System) UL LISTED Important Read set-up instructions before assembly. Report any shortages within 72 hours Specializing in Environmental and Fire-Life

More information

An Oracle White Paper January 2011. Protecting Your Archival Data With Improved Tape Dimensional Stability

An Oracle White Paper January 2011. Protecting Your Archival Data With Improved Tape Dimensional Stability An Oracle White Paper January 2011 Protecting Your Archival Data With Improved Tape Dimensional Stability Protecting Your Archival Data With Improved Tape Dimensional Stability Executive Overview... 1

More information

Trane CleanEffects. Patented technology. Superior performance. READ ONLY

Trane CleanEffects. Patented technology. Superior performance. READ ONLY Trane CleanEffects Patented technology. Superior performance. Trane CleanEffects is unlike anything else out there. So is the air it produces. Today s air needs tomorrow s air cleaning system. There may

More information

HVAC Air Systems. Recirculation Air System Types

HVAC Air Systems. Recirculation Air System Types HVAC Air Systems Recirculation Air System Types Summary Recirculation air handler fan energy can account for 10 to 30% of total cleanroom energy use. There are three fundamental recirculation system configurations:

More information

AIR CONDITIONING PRODUCTS COMPANY

AIR CONDITIONING PRODUCTS COMPANY Quality Products Fixed Louvers AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter

More information

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP Construction Indoor Air Quality Management Plans for LEED Matt Gregg, PE, LEED AP Agenda What is a Construction IAQ Management Plan? What are the LEED Requirements? What is the Mechanical Contractor s

More information