AIR CONDITIONING & PRESSURIZATION

Size: px
Start display at page:

Download "AIR CONDITIONING & PRESSURIZATION"

Transcription

1 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 1 AIR CONDITIONING & PRESSURIZATION 1. GENERAL Conditioned air comes from either the aircraft air-conditioning system or a preconditioned ground source. (engines, APU, ground cart) Air from the preconditioned ground source enters the air-conditioning system through the mix manifold. The air-conditioning system provides temperature controlled air by processing bleed air from the engines, APU or a pneumatic ground source through two air-conditioning packs. Conditioned air from the left pack flows directly to the cockpit. Excess air from the left pack, air from the right pack and air from the recirculation system is mixed in the mix manifold. The mixed air is then distributed to the passenger cabin. Recirculation Fan(s) control the recirculation system which maintains proper ventilation while economizing the use of bleed air. It collects air from the aircraft cabin, filters it and returns it to the mix manifold to be mixed with fresh conditioned air supplied by the packs /-500 Pack control is provided by the two temperature selectors and cabin temperature sensors. Pack temperature control is unbalanced. The Control Cabin (cockpit) Temperature Selector controls the pack outlet temperature of the left pack. The Passenger Cabin Temperature Selector and Cabin Temperature Sensor control the pack outlet temperature of the right pack. Since excess air from the left pack is mixed with the air from the right pack in the mix manifold, changing the pack outlet temperature of the left pack (via the Control Cabin Temperature Selector) will also change the outlet temperature of the right pack to obtain the same temperature demand for the passenger cabin /-800/-900 Pack temperature control is balanced. The outlet temperature of both packs is normally controlled at the same temperature by two electronic controllers. The pack outlet temperature is determined by the zone that requires the most cooling (Control Cabin, Forward Cabin or Aft Cabin). A three-zone trim air system provides individual zone temperature control by adding high temperature air from the pneumatic system to those zones that have a higher temperature demand than the pack outlet temperature. Any trim air failure will cause the packs to revert to independent operation. Only in case of failure of the trim air system, pack temperature control will become unbalanced. 2. MAIN COMPONENTS & SUBSYSTEMS BLEED AIR SUPPLY The pack valves control the flow of bleed air from the aircraft pneumatic system to the air conditioning packs. A single pack is capable of maintaining pressurization and acceptable temperature throughout the aircraft. Two pack operation from a single engine bleed air source is not recommended due to excessive bleed requirements.

2 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 2 PACK TEMPERATURE CONTROL /-500 Cockpit and Cabin temperature is controlled by two controllers, controlling respectively the LH and RH Pack temperatures. This is automatic using an auto temp. controller with a manual control as back up. PACK AND ZONE TEMPERATURE CONTROL /-800/-900 There are three zones : control cabin (cockpit), forward cabin and aft cabin. Desired zone temperature is set by adjusting the individual Temperature Selectors. The packs produce an air temperature which will satisfy the zone which requires the most cooling. Zone temperature is controlled by adding the proper amount of trim air to the air leaving the mix manifold through the zone supply ducts. The quantity of trim air is regulated by individual trim air modulating valves. If air in a zone supply duct overheats, the associated amber ZONE TEMP light illuminates, and the associated trim air modulating valve closes. The trim air modulating valve may be reopened after the duct has cooled by pushing the TRIP RESET Switch. Electronic Controllers Control is performed by two electronic controllers, the left and right electronic controller which have the following functions: Left controller Right controller - AFT CABIN zone - FWD CABIN zone - back-up control of CTL CABIN zone - primary control of CTL CABIN zone - LH pack temp control valve - RH pack temp control valve - RH pack standby temp control valve - LH pack standby temp control valve - LH ram-air door - RH ram-air door Zone Temperature Control Modes The left electronic controller controls the aft cabin zone and provides backup control for the cockpit. The right controller controls the forward cabin zone and provides primary control for the cockpit. Failure of the primary cockpit temperature control will cause an automatic switch to the backup control and will illuminate the CONT CAB amber ZONE TEMP Light upon Master Caution Recall. Failure of both the primary and standby controls will illuminate the light automatically. Failure of the forward or aft cabin temperature control will cause the associated trim air modulating valve to close. The Temperature Selectors operate normally, but the Temperature Selector settings of the two passenger cabin zones will be averaged. The amber ZONE TEMP Light will illuminate upon Master Caution Recall to indicate failure of the associated zone control. During single pack operation, the Temperature Selector settings of all three zones will be averaged. 3. AIR CONDITIONING PACK /-500 The flow of bleed air from the main pneumatic duct through each air conditioning pack is controlled by the respective pack valve. The left and right packs are completely independent. (Left pack supplies 20% to cockpit & 80 % to mix manifold while Right pack supplies 100 % to manifold smoke into the cockpit has a great chance to come from the Left pack) Cabin altitude can be maintained with only one pack operating.

3 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 3 Normally the left pack uses bleed air from engine no. 1 and the right pack uses bleed air from engine no. 2. The output of the packs is combined in the mix manifold. Air Mix Valves Air that flows through the cold mix valve is processed through a cooling cycle and then combined with hot air flowing from the hot mix valve in the mixing chamber. For each pack, the two air mix valves control hot and cold air according to the setting of the Control Cabin or Passenger Cabin Temperature Selector. In the automatic temperature mode, the mix valves are operated by the temperature controller. The temperature controller uses inputs from the respective Temperature Selector and cabin temperature sensor. The automatic temperature controller is bypassed when the Temperature Selector is positioned to MANUAL. Anytime the pack valve closes, the air mix valves are automatically driven to the full cold position. This aids start up of the cooling cycle and prevents nuisance hot air trips when the air conditioning pack is switched on. Cooling Cycle The flow through the cooling cycle starts by passing through a primary heat exchanger. Air flows to the compressor of an air cycle machine where the air is compressed and temperature increased. Next, the air circulates through a secondary heat exchanger for additional cooling. The airflow then passes through the turbine of the air cycle machine where it is cooled by expansion. The cold air flows to a water separator which removes moisture that has condensed out of the air by operation of the air cycle machine. The moisture extracted from the air is injected in the ram air duct to aid in cooling the heat exchangers. To prevent icing in the water separator, a temperature sensor signals the water separator anti-ice valve to provide some warming air automatically. The processed cold air is then combined with hot air in the mixing chamber. The conditioned air flows into the mix manifold and distribution system. Overheat protection is provided by temperature sensors located in the air cycle machine. An overheat condition in the compressor outlet duct or turbine inlet duct causes the pack valve to close and the PACK TRIP OFF Light to illuminate. Airflow Control With both Air Conditioning Pack Switches in AUTO and both packs operating, the packs provide "normal air flow". However, with one pack valve closed, the other pack automatically switches to "high flow" in order to maintain the necessary ventilation rate. This automatic switching is inhibited on ground, or in flight with the flaps extended, to insure adequate engine power for single engine operation. If both Engine Bleed Air Switches are OFF and the APU Bleed Air Switch is ON, the working pack is fixed in "high flow". High flow mode can be manually selected by positioning the Pack Switch to HIGH.

4 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 4 4. AIR CONDITIONING PACK /-800/-900 The flow of bleed air from the main pneumatic duct to each air conditioning pack is controlled by the respective pack valve. The packs are independent and normally operate in parallel. Normally, the left pack uses bleed air from Engine No. 1 and the right pack uses bleed air from Engine No. 2. The output of the packs is combined in the mix manifold. (Left pack supplies 20% to cockpit & 80 % to mix manifold while Right pack supplies 100 % to manifold smoke into the cockpit has a great chance to come from the Left pack) Cabin altitude can be maintained with only one pack operating. Two pack operation from a single engine bleed air source is not recommended due to excessive bleed requirements. Cooling Cycle Flow through the cooling cycle begins as bleed air passes through the primary heat exchanger. Air is then routed to the compressor section of the air cycle machine where as it is compressed the temperature increases. Next the air circulates through a secondary heat exchanger for additional cooling. The air then passes through a high pressure water separator where air is dehumidified. The moisture extracted from the air is injected into the ram air duct to aid in cooling the heat exchangers. The air then passes through the turbine section of the air cycle machine, where final cooling by expansion occurs. To prevent icing in the water separator, a temperature sensor signals the electronic controllers to increase the Air Cycle Machine turbine outlet temperature. The processed cold air is then combined with hot air which has bypassed the air cycle machine through the pack temperature control valve. This conditioned air then flows back through the high pressure water separator and into the mix manifold and distribution system. Overheat protection is provided by temperature sensors located in the air cycle machine and pack outlet. An overheat condition in the compressor outlet duct, turbine inlet duct, or pack discharge outlet will cause the PACK Light to illuminate and the pack valve to close resulting in a pack shutdown. Pack Temperature Control Electronic controllers command the pack temperature control valve toward open or closed to satisfy pack discharge requirements. If a primary pack control fails, the affected pack is controlled by the standby pack control in the opposite controller. A primary or standby pack control failure causes the PACK, Master Caution and AIR COND annunciator Lights to illuminate upon Master Caution recall. If both the primary and the standby pack controls fail for the same pack, the PACK, MASTER CAUTION and AIR COND annunciator Lights illuminate. The pack will continue to operate without control unless excessive temperatures cause the pack to trip off. Airflow Control With both Air Conditioning Pack Switches in AUTO and both packs operating, the packs provide, normal air flow. However, with one pack valve closed, the other pack automatically switches to "high flow" in order to maintain the necessary ventilation rate. This automatic switching is inhibited on ground, or in flight with the flaps extended, to insure adequate engine power for single engine operation. Automatic switching also occurs if both Engine Bleed Air Switches are OFF and the APU Bleed Air Switch is ON, since the working pack is then fixed in "high flow". High flow mode can be manually selected by positioning the Pack Switch to HIGH.

5 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 5 5. RAM AIR SYSTEM The ram air system is used to provide cooling for the heat exchangers in the air conditioning system. Operation of the system is automatic. During flight, the ram air modulating system automatically regulates airflow through the system. A temperature sensor in the air cycle machine (ACM) compressor discharge duct commands, ( /-500) a ram air controller ( /-800/-900) the left and right electronic controllers, which controls airflow through the system. The controller modulates the mechanically linked ram door and ( /-400/-500) exhaust louvers to maintain the required cooling airflow across the heat exchangers. In normal cruise, the ram doors modulate between open and closed. On ground, or in flight with the flaps not up, the ram door will move to the full open position for maximum cooling. The RAM DOOR FULL OPEN Light illuminates whenever the ram door is fully open /-400 A turbofan is located in each ram air exit duct just upstream of the exit louvers. It augments the ram airflow on ground or in flight with the flaps not retracted. The fan operates pneumatically using bleed air. It is activated electrically, when the pack is on, by the air-ground safety sensor or flap limit switch /-700/-800/-900 A turbofan, mechanically driven by the air cycle machine, augments the ram airflow. Deflector Door A deflector door is installed forward of the ram air inlet doors to prevent debris ingestion prior to liftoff and after touchdown. The deflector door extends electrically when air-ground safety logic is in the ground mode. 6. AIR CONDITIONING DISTRIBUTION Conditioned air is collected in the mix manifold. The temperature of the air is directly related to the setting of the Temperature Selectors. Cockpit Since the cockpit requires only a fraction of the air supply provided by the left pack, most of the left pack output is routed to the mix manifold. Conditioned air for the cockpit branches into several risers which end at the floor, ceiling and foot level outlets. There are air diffusers on the floor under each seat. They cannot be controlled and air flows continuously as long as the manifold is pressurized. Overhead diff users are located on the cockpit ceiling, above and aft of the no.3 windows. Each of these outlets can be opened or closed as desired by turning a slotted adjusting screw. There is also a dual purpose valve behind the rudder pedal of each pilot. These valves provide air for warming the pilot's feet and for defogging the inside of the no. 1 windshields. Each valve is controlled by knobs located on the Captain's and First Officer's panel.

6 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 6 Passenger Cabin The passenger cabin supply distribution system consists of the mix manifold, sidewall risers, and an overhead distribution duct. Sidewall risers go up the right and left wall of the passenger cabin to supply air to the overhead distribution duct. The overhead distribution duct routes conditioned air to the passenger cabin. It extends from the forward to the aft end of the ceiling along the aircraft centerline and also supplies the sidewall diffusers. Forward Cargo Compartment The forward cargo compartment is warmed in flight when more than 1.0 psi pressure differential exists. Air from the E & E compartment flows up and around the forward cargo compartment lining. The recirculation fan maintains this warming air flow. With the recirculation fan(s) off, the forward outflow valve remains open to ensure this warm air flow (except when the main outflow valve is nearly closed in order to maintain pressurization). Conditioned Air Source Connection A ground air conditioning source may be connected to the mix manifold. Recirculation Fans /-500 The recirculation fan system reduces the air conditioning pack load and the engine bleed air demand. The air for the recirculation fan is exhaust air from the main cabin and electrical equipment bay collected in a shroud located above the forward cargo compartment. (basic principle : it reduces bleed demand by the packs by increasing the volume of air into the mix manifold; it reduces also air conditioning system pack load & creates low pressure area to pull EE compartment hot air to radiate around forward cargo bin) This air is filtered and recirculated to the mix manifold (full cabin air exchange every 2 or 3 hours). The fan operates with the switch in AUTO except with both packs on and one or both in HIGH. The fan is driven by an AC motor. Overheat Detection /-500 Overheat detection is provided by temperature sensors located downstream of the packs. An overheat condition causes the appropriate mix valves to drive to full cold and the DUCT OVERHEAT Light to illuminate. A temperature higher than the duct overheat causes the appropriate pack valve to close and the PACK TRIP OFF Light to illuminate. Recirculation Fans /-800/-900 The recirculation fan system consists of two fans and reduces the air conditioning pack load and the engine bleed air demand. The air for the recirculation fans is exhaust air from the main cabin and electrical equipment bay. (basic principle : it reduces bleed demand by the packs by increasing the volume of air into the mix manifold; it reduces also air conditioning system pack load & creates low pressure area to pull EE compartment hot air to radiate around forward cargo bin) This air is filtered and recirculated to the mix manifold. (full cabin air exchange every 2 or 3 hours) The fans are driven by AC motors. Each recirculation fan will operate only if the respective RECIRC FAN Switch is selected to AUTO. In flight, if both packs are operating and either pack is switched to HIGH, the left recirculation fan will shut off. The right recirculation fan will operate in flight unless both packs are in high. On ground, the right recirculation fan will operate even if both Pack Switches are in HIGH. The left recirculation fan will operate on ground except when both packs are in HIGH.

7 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 7 Overheat Detection /-800/-900 Overheat detection is provided by temperature sensors located downstream of the packs and the mix manifold. An overheat condition causes the appropriate trim air modulating valve to close and the ZONE TEMP Light to illuminate. 7. EQUIPMENT COOLING EFIS equipment, circuit breaker panels in the cockpit and electronic equipment in the E & E compartment are cooled by the equipment cooling system. Warm air from the equipment is routed to the forward cargo compartment or dumped overboard. Flight Instrument panels and circuit breaker panels in the cockpit and electronic equipment in the E & E compartment are cooled by the equipment cooling system. Warm air from the equipment is ducted away by an AC powered exhaust fan. On ground, or with the cabin differential pressure less than 1.0 psi, the exhaust fan air is routed through a flow control valve ( /-400/-500) or overboard exhaust valve ( /-700/-800/- 900) and dumped overboard at the bottom of the aircraft. With increasing airflow at greater cabin differential pressures, the flow control valve closes. Warm air from the electronic equipment is then diffused around the forward cargo compartment. Failure of an equipment cooling fan illuminates the respective Equipment Cooling OFF Light. Selecting the alternate fan should restore airflow and extinguish the OFF Light. The supply fan draws cool air from the passenger cabin and furnishes it to the Flight Instrument panels. The exhaust fan draws air from the Flight Instrument panels, CB panels and E & E compartment. Additional thermal switches are located in the E & E compartment. If an overtemperature occurs on ground or if the equipment cooling fails, alerting is provided through the crew call horn in the nose wheel well. Normal power = Main Bus No.1 / Alternate power = Main Bus No.2 (if APU is INOP or you try to taxiin on 1 engine without APU, you will get the lights & horn! For B737s NG, if the EQUIP COOLING SUPPLY OFF light illuminates during flight indicating a subsequent failure of the remaining associated fan, continued flight > 30 minutes can result in a loss of Captain's Display Units & the Lower Center Display Unit. if the EQUIP COOLING EXHAUST OFF light illuminates during flight indicating a subsequent failure of the remaining associated fan, continued flight > 30 minutes can result in a loss of F/O's Display Units & the Upper Center Display Unit. 8. PRESSURIZATION The aircraft is pressurized by bleed air supplied to and distributed by the air conditioning system. Pressurization and ventilation are controlled by varying the opening of outflow valves. A proportional relationship is maintained between ambient and cabin pressure in climb or descent, and a maximum differential is normally maintained in cruise. Cabin pressurization is controlled by regulating the discharge of conditioned air through the outflow valves. Pressurization control is provided by the Electronic Cabin Pressure Controller which controls the main outflow valve. The main outflow valve controls the air flow out of the airplane fuselage & it is actuated : /400 : by an AC or a DC motor /700/800/900 : by 3 DC motors. (all use the same actuator mechanism)

8 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 8 Pressure Relief Valves Two pressure relief valves provide maximum safety pressure relief by limiting the differential pressure to a maximum of 8.65 psi ( /-700/-800/-900 : 9.1 psi). A negative relief valve prevents external atmospheric pressure from exceeding internal cabin pressure. (you can check it during the walkaround by pushing door inward) Pressurization Control /-400/-500 Pressurization control in provided automatically by a single pressurization controller. The pressurization system controls cabin altitude in anyone of four modes: AUTO - Automatic; the normal mode of operation. Uses AC motor. STBY - Semi-automatic; a standby system in the event of AUTO failure. Uses DC motor. MAN AC - Manual control of the system using AC motor. MAN DC - Manual control of the system using DC motor. In the automatic mode of operation, aircraft altitude is sensed directly from the static ports. In the standby mode, aircraft altitude is sensed electrically from the Air Data Computer (ADC). Barometric corrections to these pressures come from the Captain's altimeter in AUTO and the First Off icer's altimeter in STBY. The controller receives additional information from the air/ground safety sensor and cabin pressure altitude sense port. The main outflow valve can be actuated by either an AC or a DC motor. The AC motor is used during AUTO and MAN AC operation. The DC motor is used during STANDBY and MAN DC operation. The forward outflow valve closes automatically to assist in maintaining cabin pressure when the main outflow valve is almost closed or when the recirculation fan is operating. On aircraft, the system considers the operation of the right recirculation fan. Pressurization Control /-700/-800/-900 Pressurization control is provided automatically by two pressurization controllers. The pressurization system controls cabin altitude in anyone of 3 modes. AUTO - Automatic; the normal mode of operation. If the active controller fails, automatic switching will occur to the remaining controller. ALTN - Cabin pressure control is controlled by the remaining controller. MAN - Manual control mode if AUTO and ALTN modes are unserviceable. Barometric altitude is provided by the Air Data Inertial Reference Units (ADIRUS) that receive barometric correction inputs from the Captain's and First Officer's BARO Set knobs. The is equipped with one (main) outflow valve, actuated by DC motors only. 9. PRESSURIZATION OUTFLOW /-400/-500 Cabin air outflow is controlled by the main outflow valve, the forward outflow valve, and the flow control valve. During pressurized flight, the flow control valve is closed, and the majority of the overboard exhaust is through the main outflow valve. Passenger cabin air is drawn through foot level grills, down around the aft cargo compartment, where it provides heating, and is discharged overboard through the main outflow valve. A small amount is also exhausted through the toilet and galley vents, miscellaneous fixed vents, and by seal leakage. The flow control valve opens to exhaust the cooling air from the E & E compartment overboard during ground operation, unpressurized flight, and pressurized flight below a cabin differential pressure of approximately 1.0 psi.

9 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 9 When the flow control valve closes, air is directed around the forward cargo compartment liner for inflight heating. The forward outflow valve is the overboard discharge exit for air circulated around the forward cargo compartment (located approximately under first cabin window on Left side of the aircraft). The valve is closed whenever the recirculation fan is operating. You can "refresh" the aircraft (for example with Full PAX load) by placing R pack to HI (RECIRC fan is then turned OFF & the forward outflow valve is opened adding more fresh air ) On aircraft, the valve is closed whenever the right recirculation fan is operating /-700/-800/-900 Cabin air outflow is controlled by the main outflow valve and the overboard exhaust valve. During pressurized flight, the overboard exhaust valve is closed, and the majority of the overboard exhaust is through the main outflow valve. Passenger cabin air is drawn through foot level grills, down around the aft cargo compartment, where it provides heating, and is discharged overboard through the main outflow valve. A small amount is also exhausted through the toilet and galley vents, miscellaneous fixed vents, and by seal leakage. On ground and in flight with low differential pressure, the overboard exhaust valve is open and warm air from the E & E bay is discharged overboard. In flight, at higher cabin differential pressure, the overboard exhaust valve is normally closed and exhaust air is diffused to the lining of the forward cargo compartment. However, the overboard exhaust valve remains open if both pack switches are in high and the recirculation fan is off. This allows for increased ventilation in the smoke removal configuration as there is no forward outflow valve installed. 10. PRESSURIZATION CONTROL /-400 Auto Mode Operation In AUTO, the pressurization control panel is used to preset two altitudes into the pressure controller : - FLT ALT (flight or cruise altitude). - LAND ALT (destination airport altitude). Take-off airport altitude (actually cabin altitude) is automatically fed into the pressurization controller at all times when on ground. The air/ground safety sensor signals whether the aircraft is on ground or in flight. On ground, the FLT/GRD switch is used to keep the cabin depressurized by driving the main outflow valve full open when the switch is in the GRD position. With the switch in the FLT position, the controller modulates the main outflow valve toward close, pressurizing the cabin to.1 psid. This ground pressurization of the cabin makes the transition to pressurized flight more gradual for the passengers and crew, and also gives the system better response to ground effect pressure changes during take-off. In flight, the pressure controller maintains a proportional pressure differential between flight and cabin altitude. By climbing the cabin altitude at a rate proportional to the aircraft climb rate, cabin altitude change is held to the minimum rate required. Maximum cabin rate is 500 sea level ft/min during climb and 350 sea level ft/min during descent. Approximately feet below flight altitude (actually when outside air pressure is within.25 psid of the pressure that will exist when the aircraft is at selected FLT ALT) a cruise relay trips. The controller schedules a constant cabin altitude during cruise using a 7.45 psid (7.80 psid with FLT ALT > ft) between flight and cabin altitudes. An amber OFF SCHED DESCENT Light illuminates if the aircraft begins to descend without the cruise relay being tripped; for example, a flight aborted in climb and returning to the take-off airport. The controller programs the cabin to land at the take-off field elevation without further pilot inputs.

10 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 10 If the Flight Altitude Indicator is changed or the Flight Altitude Selector is depressed during climb, the automatic cabin abort capability to the original take-off field elevation will be lost. During isobaric cruise, minor excursions from flight altitude may cause the pressure differential to go as high as 7.90 psid to maintain a constant cabin altitude. Beginning descent, approximately feet below cruise altitude (.25 psid), a descent relay trips, scheduling the cabin to begin a proportional descent to the selected LAND ALT. The controller programs the cabin to land slightly pressurized (.1 psid), so that rapid changes in altitude during approach result in minimum cabin pressure changes. Taxiing in, the controller drives the main outflow valve slowly to full open when the FLT/GRD Switch is positioned to GRD, thereby depressurizing the cabin. Having the main outflow valve full open also prevents the equipment cooling exhaust fan from depressurizing the aircraft to a negative pressure. An amber AUTO FAIL Light illuminates if any one of three conditions occur : - Loss of AUTO AC power. - Excessive rate of cabin pressure change (exceeding 1800 sea level feet/minute). - High cabin altitude (exceeding 13,875 feet). With illumination of the AUTO FAIL Light, the pressure controller automatically changes to the STANDBY mode; however, the Pressurization Mode Selector remains in AUTO. Positioning the Mode Selector to STBY extinguishes the light. Standby Mode Operation A green STANDBY Light will be illuminated when the pressure controller is in the STANDBY mode. In the STANDBY mode the controller allows maximum 7.90 psid. On ground, the GRD position of the FLT/GRD Switch drives the main outflow valve full open. The FLT position drives the main outflow valve to attempt to pressurize the cabin to the selected CAB ALT. CAB ALT should be set 200 feet below the take-off airport altitude to pressurize the cabin properly when the FLT/GRD Switch is placed to FLT prior to take-off. In flight, by referring to the placard below the pressurization control panel, the Cabin Altitude Indicator is set to the isobaric cabin altitude, based on the flight altitude. Cabin rate of climb or descent is controlled by the Cabin Rate Selector. In descent, the Cabin Altitude Indicator is set 200 feet below landing field altitude to insure a pressurized cabin during landing. Manual Mode Operation A green MANUAL Light illuminates with the Pressurization Mode Selector in MAN AC or MAN DC. Manual mode allows the pilot, by using the Outflow Valve Switch, to modulate the main outflow valve while monitoring the Outflow Valve Position Indicator. MAN AC mode uses the AC motor to control the main outflow valve; MAN DC uses the DC motor. Full travel of the outflow valve in MAN AC requires approx. 2 seconds, in MAN DC approx. 6 seconds. 11. PRESSURIZATION CONTROL /-700/-800/-900 Auto and Alternate Mode Operation The AUTO system consists of two identical controllers, with one controller alternately sequenced as the primary operational controller for each new flight, The other automatic controller is available as a backup. In the AUTO or ALTN mode, the pressurization control panel is used to preset two altitudes into the auto controllers: - FLT ALT (flight or cruise altitude); - LAND ALT (destination airport altitude).

11 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 11 Take-off airport altitude (actually cabin altitude) is fed into the auto controllers at all times on ground. The air/ground safety sensor and engine N1 (from the Stall Management Computer) are inputs for the controllers. On ground and at lower power settings, the cabin is depressurized by driving the outflow valve to the full open position. The cabin begins to pressurize on the ground at higher power settings. The controller modulates the outflow valve toward close, slightly pressurizing the cabin. This ground pressurization of the cabin makes the transition to pressurized flight more gradual for the passengers and crew, and also gives the system better response to ground effect pressure changes during take-off. In flight, the auto controller maintains a proportional pressure differential between aircraft and cabin altitude. By increasing the altitude at a rate proportional to the aircraft climb rate, cabin altitude change is held to the minimum rate required. An amber OFF SCHED DESCENT light illuminates if the aircraft begins to descend without having reached the preset cruise altitude; for example, a flight aborted in climb and returning to the take-off airport. The controller programs the cabin to land at the take-off field elevation without further pilot inputs. If the FLT ALT indicator is changed, the automatic return to the original take-off field elevation is lost. The cruise mode is activated when the aircraft climbs to within 0.25 psid of the selected FLT ALT. During cruise, the controller maintains a pressure differential of 8.35 psid (above 37,000 feet), 7.80 psid (between 28,000 or 37,000 feet) or 7.45 psid (less than 28,000 feet). Deviations from flight altitude may cause the pressure differential to go as high as 8.45 psid to maintain a constant cabin altitude. The descent mode is activated when the aircraft descends 0.25 psi below the selected FLT ALT. The cabin begins a proportional descent to slightly below the selected LAND ALT. The controller programs the cabin to land slightly pressurized so that rapid changes in altitude during approach result in minimum cabin pressure changes. While taxiing in, the controller drives the outflow valve slowly to full open to depressurize the cabin. An amber AUTO FAIL Light illuminates if any of the following conditions occur : - Loss of DC power. - Controller fault in the operational controller. - Excessive rate of cabin pressure change (exceeding 2000 sea level feet/minute). - High cabin altitude (exceeding 15,800 feet). With illumination of the AUTO FAIL light, pressurization control automatically transfers to the other auto controller (ALTN mode). Moving the pressurization mode selector to the ALTN position extinguishes the AUTO FAIL light, however the ALTN light remains illuminated. Manual Mode Operation A green MANUAL Light illuminates with the pressurization mode selector in the MAN position. In the MAN mode, the outflow valve position switch is used to modulate the outflow valve by monitoring the cabin altitude panel and valve position on the outflow valve position indicator. A separate DC motor, powered by the DC standby bus, drives the outflow valve at a slower rate than the automatic modes. Outflow valve full range of motion takes up to 20 seconds. 12. AIR CONDITIONING PANEL AIR TEMPERATURE SOURCE SELECTOR ( /-500/-600/-700) SUPPLY DUCT selects main distribution supply duct sensor for temperature selector PASS CABIN selects passenger cabin sensor for temperature indicator

12 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 12 AIR TEMPERATURE SOURCE SELECTOR ( /-800/-900) SUPPLY DUCT = CONT CAB, FWD CAB and AFT CAB PASS CAB = FWD, AFT selects FWD or AFT passenger cabin temperature PACK = R & L Selects the pack discharge temperature AUTO : automatic temp control for the associated zones rotating toward C (cool) or W (warm) sets the desired temperature (18 C to 30 C) OFF : closes the associated trim air modulating valve > the left pack will maintain a fixed temperature of 750F (24 C) the right pack will maintain a fixed temperature of 650 F (18 C) TEMPERATURE SELECTORS ( /-500/-700) (L & R) Flight deck (left) and passenger cabin (right) AUTO : temperature controlled automatically for passenger cabin controlled thru a temp sensor in cabin ceiling &controller in electronic equipment bay MANUAL (springloaded to center): moves mix valves manually (automatic temp controller bypassed) TEMPERATURE INDICATOR (all 737s) indicates temperature at location selected with the AIR TEMP source selector AIR MIX VALVE INDICATORS ( /-500/-600/-700) indicates position of air mix valves left for cockpit, right for passenger cabin controlled automatically with temperature selector in AUTO, controlled manually with temperature selector in MANUAL air mix valves go full cold when pack valve closes, duct overheat, or pack trip off TRIM AIR SWITCH ( /-800/-900) ON : trim air pressure regulating and shutoff valve signaled open allows bleed air from upstream of the packs to be directed to the three trim air modulating valves OFF : trim air pressure regulating and shutoff valve signaled closed left and / or right pack primary control will control both packs independently the left pack primary control will position the left pack temp control valve in response to the CONT CAB selector to establish the temp for the flight deck the right pack primary control will position the right pack temp control valve in response to the cooler of the AFT CAB or FWD CAB selectors to establish the temp for the passenger cabin RECIRCULATION FAN SWITCH ( /-500) AUTO : - Fan is ON, except with both packs ON & 1 or both in HIGH - 1 pack HIGH or AUTO = fan ON - Both packs OFF or AUTO = fan ON - Both packs ON & 1 or both HIGH = fan OFF OFF : fan OFF

13 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 13 RECIRCULATION FAN SWITCH ( /-800/-900) an additional recirc fan improves air circulation in the aft fuselage. AUTO In flight : - Left fan is ON when both packs are operating & at least 1 pack is in high flow - Right fan is ON except when both packs are in high flow. On ground : - Left pack will run except when both packs are operating in high flow. - The right fan will continue to run when both packs are operating in high flow OFF : fan OFF RECIRCULATION FAN SWITCH ( /-700) Same except : if the recirc fan is turned off in flight, the overboard exhaust valve (OEV) opens AIR CONDITIONING PACK SWITCH AUTO : - With both packs operating, each pack regulates to normal flow. - With 1 pack operating, regulates to high flow when in flight with flaps UP - When operating 1 pack from the APU (both engine bleed switches OFF) regulates to high flow. HIGH : - Pack regulates to high flow. OFF : - Pack is OFF. TRIP RESET SWITCH PRESS : If the fault condition has been corrected, reset : - BLEED TRIP OFF - PACK TRIP OFF ( /-400/-500) - PACK ( /-700/-800/-900) - DUCT OVERHEAT ( /-500) - ZONE TEMP ( /-800/-900) Lights remain illuminated until reset. 13. PRESSURIZATION PANEL CABIN ALTIMETER / DIFFERENTIAL PRESSURE INDICATOR - inner scale: indicates cabin altitude in feet - outer scale: indicates differential pressure between - cabin and ambient in psi - connected to alternate static system (only B /-700/-800/-900)

14 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 14 Air Conditioning & Press, Max Differential pressure (limitation) - Max differential pressure limit : 8.65 psi (B /-400/-500) - Max differential pressure limit : 9.1 psi (B /-700/-800/-900) - Max cabin differential for Takeoff/Landing.1 25 psi Air Conditioning & Press, Max Differential pressure (operations) Max operating differential psi : ±.1 psi above FL ±.1 psi at or below FL psi above FL370 (only B /-700/-800/-900) CABIN RATE OF CLIMB INDICATOR - indicates rate of climb or descent in fpm, normally on descent the auto mode uses a maximum of 350 fpm; on climb, its maximum is 500 fpm - detects pressure changes from a port on the back of the indicator ALT HORN CUTOUT SWITCH - cuts cabin altitude warning horn (goes off when cabin reaches altitude = ft) Two types of pressure controllers : Electronic & Digital - Non-EFIS aircraft use the Electronic pressure controller - EFIS and B /-700/-800/-900 aircraft uses the Digital pressure controller FLIGHT ALTITUDE INDICATOR - shows selected cruise flight altitude (set before takeoff) LANDING ALTITUDE INDICATOR - indicates altitude of destination airport CABIN RATE SELECTOR (ONLY ELECTRONIC PRESSURIZATION CONTROLLER) - DECR : cabin altitude rate of change equals 50 ft/min - INCR : cabin altitude rate of change equals 2000 ft/min - index : cabin altitude rate of change equals 300 ft/min. CABIN ALTITUDE SELECTOR (ONLY ELECTRONIC PRESSURIZATION CONTROLLER) Rotate : - to set desired cabin altitude - Outer knob sets 1000 feet increments - Inner knob sets 10 feet increments For standby use : - Cruise : use placard chart - T/O & Landing : use landing field elevation minus 200 ft OUTFLOW VALVE POSITION INDICATOR - indicates position of aft outflow valve (operates in all modes) OUTFLOW VALVE SWITCH (spring loaded to center) Full travel 7 sec. in manual AC & 14 sec in manual DC - OPEN : opens main cabin outflow valve electrically - CLOSE : closes main cabin outflow valve electrically

15 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 15 FLIGHT GROUND SWITCH (ONLY ELECTRONIC PRESSURIZATION CONTROLLER) - GRD : On the ground drives outflow valve open at a rate selected by Cabin Rate Indicator Inhibited after takeoff (functions the same as FLT position) - FLT : pressurizes aircraft at rate selected by Cabin Rate Selector to cabin altitude selected on Cabin Altitude Indicator. PRESSURIZATION MODE SELECTOR (ONLY ELECTRONIC PRESSURIZATION CONTROLLER) - CHECK : tests auto feature function of AUTO system - AUTO : airplane pressurization system controlled automatically using CAPTAIN's altimeter - STBY : 1) pressurization system controlled thru the standby mode (using F/O's altimeter) 2) requires cabin altitude rate of change & cabin altitude selections (auto mode is bypassed) 3) allows maximum 7.90 psi. - MANUAL : airplane pressurization controlled manually by outflow valve switch (all AUTO & STBY circuits are bypassed. 1) AC : - Outflow valve operates from AC power which is at a faster rate - Used by AUTO mode (full travel in 7 sec.) 2) DC : - Outflow valve operates from DC power which is at a slower rate (half speed) - Used by STBY mode (full travel in 14 sec.) & for emergency evacuation. DIGITAL PRESS MODE SELECTOR (ONLY DIGITAL PRESSURIZATION CONTROLLER) - AUTO : airplane pressurization system controlled automatically using CAPTAIN's altimeter - ALTN : 1) pressurization system controlled automatically using alternate controller 2) AUTO FAIL amber light goes off when you select the ALTN position 3) the active controller changes with every flight or in case of an AUTO FAIL event. - MAN : - Both cabin pressure controllers are bypassed - Pressurization system is controlled manually by outflow valve switch

16 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page FAULTS & INDICATIONS VALID FOR SERIES LIGHT INDICATION ALTN AUTO FAIL AUTO FAIL BLEED TRIP OFF DUAL BLEED DUCT OVERHEAT MANUAL - illumination of both ALTN & AUTO FAIL indicates a single controller failure & automatic transfer to ALTN mode - Pressurization mode selector in ALTN position. if any one of these 3 conditions occur : - Loss of AUTO AC power - Excessive rate of cabin pressure change (> 1800 SL ft/min). - High cabin altitude (> 13,875 ft). if any of these 4 following conditions occur : - Loss of DC power. - Controller fault in the operational controller. - Excessive rate of cabin pressure change (> 2000 SL ft/min). - High cabin altitude (> 15,800 ft). excessive engine bleed air temperature or pressure is sensed : - related engine bleed air closes automatically - requires reset. whenever there is a potential risk for backpressuring the APU+ APU bleed air valve open & engine No.1 Bleed air switch ON, APU Bleed air valve & isolation valve open. Indicates passenger cabin duct overheat (temp mix valves drive full cold). Pressurization system operating in the manual mode X X X X X X X X X X X X X X X X X X X X X X X X X X OFF OFF SCHED DESCENT PACK - EQUIPMENT COOLING EXHAUST OFF LIGHT = no airflow from the selected cooling exhaust fan - EQUIPMENT COOLING SUPPLY OFF LIGHT = no airflow from the selected cooling supply fan Aircraft descended before reaching the planned cruise altitude set in the FLT ALT indicator. - Indicates pack trip off due to overheat or indicates failures of both primary & standby pack controls (Pack continue to operate) - During Master Caution recall, indicates failure of either primary or standby pack control. Will extinguish upon Master Caution reset. X X X X X X X X X X

17 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 17 VALID FOR SERIES LIGHT INDICATION PACK TRIP OFF RAM DOOR FULL OPEN indicates a pack trip off. Packs valve automatically X X X X closes & mix valves drive full cold. Trips are caused by pack temperatures exceeding limits or duct overheat. Ram door in full open position. X X X X X X Pressurization system operating in standby mode. X X X MANUAL ZONE TEMP - CONT CAB indicates a duct overheat, or failure of the cockpit primary and standby temperature control. - FWD CAB/AFT CAB indicates duct overheat. - During Master Caution recall, the illumination of the CONT CAB Light indicates failure of the cockpit primary or standby temperature control. Illumination of either FWD or AFT CAB Light indicates failure of the associated zone temperature control. Will extinguish upon Master Caution reset. X X

18 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 18

19 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 19

20 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 20

21 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 21

22 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 22

23 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 23

24 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 24 EQUIPMENT COOLING

25 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 25

26 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 26

Bombardier Challenger 605 - Air Conditioning & Pressurization

Bombardier Challenger 605 - Air Conditioning & Pressurization GENERAL The air conditioning system provides temperature-regulated, conditioned air to the cockpit and passenger cabin using two air conditioning units (ACU s), commonly referred to as packs. An electric

More information

AIR - PNEUMATIC, AIR CONDITIONING, PRESSURIZATION

AIR - PNEUMATIC, AIR CONDITIONING, PRESSURIZATION AIR - PNEUMATIC, AIR CONDITIONING, PRESSURIZATION PNEUMATIC SYSTEM The Pneumatic System is normally supplied by the Engine's compressor sections. The Pneumatic System may also be supplied by APU bleed

More information

Pneumatic Air Conditioning Pressurization

Pneumatic Air Conditioning Pressurization EMBRAER 135/145 Pneumatic Air Conditioning Pressurization GENERAL The pneumatic system can be supplied by the engines, APU or a ground pneumatic source. The APU or ground pneumatic source supplies the

More information

ELECTRICAL. Primary electrical power is provided by two engine driven generators which supply three-phase, 115 volt 400 cycle alternating current.

ELECTRICAL. Primary electrical power is provided by two engine driven generators which supply three-phase, 115 volt 400 cycle alternating current. Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 1 ELECTRICAL 1. GENERAL Primary electrical power is provided by two engine driven generators which supply three-phase, 115 volt 400 cycle alternating current.

More information

WATER AND WASTE SYSTEMS WATER AND WASTE SYSTEMS

WATER AND WASTE SYSTEMS WATER AND WASTE SYSTEMS WATER AND WASTE SYSTEMS Table of Contents Vol. 1 21--00--1 REV 56, Jan 31/03 CHAPTER 21 --- WATER AND WASTE SYSTEMS Page TABLE OF CONTENTS 21-00 Table of Contents 21--00--1 INTRODUCTION 21-10 Introduction

More information

Introduction to Aircraft Design and Aviation Systems (ENG3005)

Introduction to Aircraft Design and Aviation Systems (ENG3005) Chapter 3 Emergency power generation 1. Power distribution 1.1 The power source for many civil aircraft: a.main aircraft generator : through a Generator Control Breaker (GCB). Controlled by Generator Control

More information

te technical note technica

te technical note technica te technical note technica Ground Tests of Aircraft Flight Deck Smoke Penetration Resistance David Blake April 2003 DOT/FAA/AR-TN03/36 This document is available to the public through the National Technical

More information

Chapter 21 Air Conditioning

Chapter 21 Air Conditioning Chapter 21 Page Date: 8. December 1999 21 Page 1 Table of Contents 21-00-00 GENERAL...5 Description...5 Troubleshooting...6 Service and Maintenance...8 Removal / Installation...8 21-20-00 DISTRIBUTION...9

More information

SERIOUS INCIDENT. Aircraft Type and Registration: No & Type of Engines: 2 SNECMA CFM 56-7B turbofan engines. Year of Manufacture: 1999

SERIOUS INCIDENT. Aircraft Type and Registration: No & Type of Engines: 2 SNECMA CFM 56-7B turbofan engines. Year of Manufacture: 1999 SERIOUS INCIDENT Aircraft Type and Registration: No & Type of Engines: Boeing 737-86N, SE-RHX 2 SNECMA CFM 56-7B turbofan engines Year of Manufacture: 1999 Date & Time (UTC): Location: Type of Flight:

More information

FLIGHT CONTROLS 1. GENERAL 2. MAIN COMPONENTS AND SUBSYSTEMS ROLL CONTROL. Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 1

FLIGHT CONTROLS 1. GENERAL 2. MAIN COMPONENTS AND SUBSYSTEMS ROLL CONTROL. Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 1 Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 1 FLIGHT CONTROLS 1. GENERAL The primary flight controls, ailerons, elevators and rudders, are hydraulically powered. Hydraulic power is provided from hydraulic

More information

B777. Landing Gear DO NOT USE FOR FLIGHT

B777. Landing Gear DO NOT USE FOR FLIGHT B777 Landing Gear DO NOT USE FOR FLIGHT Introduction The airplane has two main landing gear and a single nose gear. The nose gear is a conventional steerable two wheel unit. Each main gear has six wheels

More information

King Air C90A. Speeds (KIAS)

King Air C90A. Speeds (KIAS) King Air C90A Speeds (KIAS) V MCA 90 V SSE 97 V X 101 V Y 111 V XSE 100 V YSE 107 V A 169 V REF 100 V MO 208 V FE 178 35% 137 100% V LE 156 129 Retraction only Other 95 Balked landing climb 125 Glide 161

More information

737 NG Comm unications

737 NG Comm unications B737 NG Comm munications 5.20 Communications-System Description Introduction The communication system includes: radio communication system interphone communication system cockpit voice recorder system

More information

FUEL. Fuel is contained in three tanks located within the wings and wing center section.

FUEL. Fuel is contained in three tanks located within the wings and wing center section. Smartcockpit.com BOEING 737 SYSTEMS REVIEW Page 1 FUEL 1. GENERAL Fuel is contained in three tanks located within the wings and wing center section. There a 3 tanks : Main tanks No. 1 and No. 2 are integral

More information

LANDING GEAR & BRAKES www.theaviatornetwork.com GTM 14.1 2005 1-30-05 CONTENTS INTRODUCTION... 14.2

LANDING GEAR & BRAKES www.theaviatornetwork.com GTM 14.1 2005 1-30-05 CONTENTS INTRODUCTION... 14.2 www.theaviatornetwork.com GTM 14.1 CONTENTS INTRODUCTION... 14.2 GENERAL... 14.2 MAIN LANDING GEAR... 14.2 Landing Gear Latch Lever and Handle... 14.2 Landing Gear Pressure Gauge... 14.2 Landing Gear Warning

More information

Section 9. Pitot Static System. 1 of 6

Section 9. Pitot Static System. 1 of 6 1 of 6 ITOT STATIC SYSTEM General The pitot static systems operate the Air Speed Indicator, Vertical Speed Indicator and the Altitude Indicator for each pilot. In addition, fitted into the Co-pilot's system,

More information

B 737 NG El ectrical

B 737 NG El ectrical B737 NG Electrical Introduction Aircraft equipped with Single Battery Primary electrical power is provided by two engine integrated drive generators (IDGs) which supply three-phase, 115 volt, 400 cycle

More information

AIRCRAFT SYSTEMS EQUIPMENT

AIRCRAFT SYSTEMS EQUIPMENT Intentionally left blank PRELIMINARY PAGES - TABLE OF CONTENTS DSC-25-10 Flight Deck DSC-25-10-10 General GENERAL... A PRINCIPLES FOR PUSHBUTTONS WITH INTEGRATED INDICATIONS...B GENERAL ARRANGEMENT...C

More information

Air Conditioning System

Air Conditioning System Air Conditioning System 1 Chonan Technical Service Training Center Chonan Technical Service Training Center 2 Objectives To understand the components of air conditioning system. To understand the control

More information

Basic Technology Series

Basic Technology Series Basic Technology Series Fundamentals of Car Air Conditioning 2007 Air Conditioning #003 The Rear Cooler Construction Fan Fan Filter Figure A : Trunk Figure B : Overhead Dual Air-Conditioner In This Issue

More information

B777. Automatic Flight DO NOT USE FOR FLIGHT

B777. Automatic Flight DO NOT USE FOR FLIGHT B777 Automatic Flight DO NOT USE FOR FLIGHT 4.10 Automatic Flight-Controls and Indicators Mode Control Panel (MCP) A/T ARM L R IAS MACH HDG TRK V/S FPA ALTITUDE A/P F/D ON OFF CLB CON IAS LNAV VNAV AUTO

More information

Section 6. Introduction to Automatic A/C. Automatic Temperature Control

Section 6. Introduction to Automatic A/C. Automatic Temperature Control Automatic Control Introduction to Automatic A/C The heating, ventilation and air conditioning (HVAC) system in a house contains a wall-mounted thermostat to control outlet temperatures, distribution and

More information

787 No-Bleed Systems: Saving Fuel and Enhancing Operational Efficiencies

787 No-Bleed Systems: Saving Fuel and Enhancing Operational Efficiencies 787 No-Bleed Systems: Saving Fuel and Enhancing Operational Efficiencies by ike Sinnett, Director, 787 Systems The Boeing 787 Dreamliner features a unique systems architecture that offers numerous advantages

More information

Electro-Mechanical Landing Gear System. Landing Gear and Brakes

Electro-Mechanical Landing Gear System. Landing Gear and Brakes Electro-Mechanical Landing Gear System N O 2 D U A L F E D B U S LANDING RELAY 5A DOWN EMERGENCY EXTENSION DOWN LIMIT GROUND AIRBORNE DOWN LIMIT Landing Gear and Brakes DOWNLOCK HOOK ENGAGED GROUND AIRBORNE

More information

AIRCRAFT RESCUE AND FIRE FIGHTING GUIDE REVISION 0. AA Flight Safety Department.4601 Hwy 360; MD 849 GSWFA.Fort Worth Texas 76155. Phone 817-967-1829

AIRCRAFT RESCUE AND FIRE FIGHTING GUIDE REVISION 0. AA Flight Safety Department.4601 Hwy 360; MD 849 GSWFA.Fort Worth Texas 76155. Phone 817-967-1829 AIRCRAFT RESCUE AND FIRE FIGHTING GUIDE REVISION 0 AA Flight Safety Department.4601 Hwy 360; MD 849 GSWFA.Fort Worth Texas 76155. Phone 817-967-1829 Copyright 2013 by American Airlines Book design by Ted

More information

This is the third of a series of Atlantic Sun Airways CAT B pilot procedures and checklists for our fleet. Use them with good judgment.

This is the third of a series of Atlantic Sun Airways CAT B pilot procedures and checklists for our fleet. Use them with good judgment. This is the third of a series of Atlantic Sun Airways CAT B pilot procedures and checklists for our fleet. Use them with good judgment. Dimensions: Span 107 ft 10 in Length 147 ft 10 in Height 29ft 7 in

More information

A/C-HEATER SYSTEM - AUTOMATIC

A/C-HEATER SYSTEM - AUTOMATIC A/C-HEATER SYSTEM - AUTOMATIC 1995 Volvo 850 1995-96 Auto. A/C-Heater Systems Volvo 850 * PLEASE READ THIS FIRST * WARNING: To avoid injury from accidental air bag deployment, read and carefully follow

More information

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB

More information

FOXAIR 60/50 ALL MODELS

FOXAIR 60/50 ALL MODELS FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,

More information

3-2. Using the air conditioning system and defogger Automatic air conditioning system

3-2. Using the air conditioning system and defogger Automatic air conditioning system Automatic air conditioning system Airflow and outlets are automatically adjusted according to the temperature setting. Press to display the air conditioning operation screen. Air conditioning operation

More information

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C) HVAC SYSTEM (HEATER, VENTILATOR, AND A/C) HEATER SYSTEM 1. Heater System A: GENERAL A semi-center type integrated air conditioning unit is used, where a high performance heater core and an evaporator core

More information

CHAPTER 11 HEATING, VENTILATION AND AIR CONDITIONING. Section Title Page

CHAPTER 11 HEATING, VENTILATION AND AIR CONDITIONING. Section Title Page CHAPTER 11 HEATING, VENTILATION AND AIR CONDITIONING Section Title Page 11.000 Heating and Ventilation............................... 11.1 11.001 Introduction................................... 11.1 11.002

More information

REMOTE CONTROL MANUAL

REMOTE CONTROL MANUAL REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read

More information

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1 Fault codes DM1 Industrial engines DC09, DC13, DC16 Marine engines DI09, DI13, DI16 03:10 Issue 5.0 en-gb 1 DM1...3 Abbreviations...3 Fault type identifier...3...4 03:10 Issue 5.0 en-gb 2 DM1 DM1 Fault

More information

Multi Engine Oral Exam Questions

Multi Engine Oral Exam Questions Multi Engine Oral Exam Questions 1. What are the requirements for a multi-engine rating? 2. What is the max rated horse power at sea level? At 12,000 msl? 3. What is the rated engine speed? 4. What is

More information

New Trends in the Field of Automobile Air Conditioning

New Trends in the Field of Automobile Air Conditioning New Trends in the Field of Automobile Air Conditioning E. Janotkova and M. Pavelek Department of Thermomechanics and Environmental Engineering Brno University of Technology, 61669 Brno, Czech Republic

More information

3. AIR CONDITIONER CONTROLLER (UNIT)

3. AIR CONDITIONER CONTROLLER (UNIT) 9 3. AIR CONDITIONER CONTROLLER (UNIT) Functions of Full Automatic Air Conditioner ler 1 1. Temp SW 2. Auto SW 3. OFF SW 4. Amb SW 5. Mode SW 6. Blower SW 2 3 10 5 8 7 9 Temperature control: Air mix actuator

More information

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU Automatic Temperature Control Diagnosis and Repair Diagnosis of Automatic A/C Systems The most common automatic A/C system malfunctions tend to be the result of basic air conditioning problems. These problems

More information

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the specifier in correctly specifying Mechanical System Testing

More information

Hydraulic Landing Gear System

Hydraulic Landing Gear System Hydraulic Landing Gear System CENTER BUS MAIN POWER RELAY 60A 5A SERVICE VALVE 5 LANDING GEAR TIME DELAY PCB TIME DELAY 14 AUX. RETURN AUX. PRESS. UP SELECTOR VALVE POWER PACK ASSEMBLY REGULATED BLEED

More information

Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves

Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves CRANE Energy Flow Solutions TM Donald H. Johnson Crane Energy Flow Solutions 1 Crane Co. Resolution Made By Richard Teller

More information

S-Tec System Thirty Autopilot

S-Tec System Thirty Autopilot Cirrus Design Section 9 Pilot s Operating Handbook and FAA Approved Airplane Flight Manual Supplement for S-Tec System Thirty Autopilot When the S-Tec System Thirty Autopilot is installed in the Cirrus

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Element D Services Plumbing

Element D Services Plumbing Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.

More information

Super King Air 200. Speeds (KIAS)

Super King Air 200. Speeds (KIAS) Super King Air 200 Speeds (KIAS) V MCA 86 V SSE 104 V X 100 V Y 125 V XSE 115 V YSE 121 V A 181 V REF 103 132 with no flap V MO 260 270 for old models M MO 0,52 0,48 for old models V FE 200 40% 146 100%

More information

Automatic air conditioning system

Automatic air conditioning system Automatic air conditioning system Air outlets and fan speed are automatically adjusted according to the temperature setting. With navigation system Owners of models equipped with a navigation system should

More information

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC Page. Basic Diagnostic Procedure.... General Description...3 3. Electrical Components Location...6 4. A/C Control Module I/O Signal...8 5. Self-diagnosis...0 6.

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

Master Minimum Equipment List

Master Minimum Equipment List U.S. Department of Transportation Federal Aviation Administration Washington, D.C. Master Minimum Equipment List Revision: 2 Date: 01/15/2016 ** FOR 14 CFR PART 91 and 135 OPERATIONS ONLY ** GULFSTREAM

More information

Nomad WINGS FLAP OPERATING LIMITATIONS

Nomad WINGS FLAP OPERATING LIMITATIONS WINGS FLAP OPERATING LIMITATIONS 1. PLANNING INFORMATION A. Effectivity (1) Aircraft affected: N22 Series line sequence numbers 1 to 9, 11 to 29, 31, 33, 35, 37, 39 to 41, 43, 45, 47 to 59, 63, 65 to 70,

More information

SINGLE ENGINE TURBO-PROP AEROPLANE ENDORSEMENT

SINGLE ENGINE TURBO-PROP AEROPLANE ENDORSEMENT SINGLE ENGINE TURBO-PROP AEROPLANE ENDORSEMENT ENGINEERING, DATA AND PERFORMANCE QUESTIONNAIRE FOR (Aeroplane make & model) Version 1-31 August 1996 Name: Endorser: (Signature/Name) Satisfactorily Completed

More information

Automatic air conditioning system

Automatic air conditioning system Automatic air conditioning system Airflow and outlets are automatically adjusted according to the temperature setting. Control panel Windshield defogger Driver s side temperature control dial Air conditioning

More information

Automatic air conditioning system

Automatic air conditioning system Automatic air conditioning system Airflow and outlets are automatically adjusted according to the temperature setting. With navigation system Owners of models equipped with a navigation system should refer

More information

Alarm and Detection/Suppression

Alarm and Detection/Suppression Alarm and Detection/Suppression Fire Safety American Fire Technologies To provide special hazard services world wide to the industrial market through the integration of components and services Clean Agent

More information

V.A.G. Service. CLIMAtronic. CLIMAtronic USE AT YOUR OWN RISK. This document is an UNOFFICIAL translation of: V.A.G. Service

V.A.G. Service. CLIMAtronic. CLIMAtronic USE AT YOUR OWN RISK. This document is an UNOFFICIAL translation of: V.A.G. Service V.A.G. Service CLIMAtronic Construction and Function Self-Study Program 135 This document is an UNOFFICIAL translation of: V.A.G. Service CLIMAtronic Konstruction and Funktion Selbststudienprogramm Nr.

More information

This is the fourth of a series of Atlantic Sun Airways CAT B pilot procedures and checklists for our fleet. Use them with good judgment.

This is the fourth of a series of Atlantic Sun Airways CAT B pilot procedures and checklists for our fleet. Use them with good judgment. This is the fourth of a series of Atlantic Sun Airways CAT B pilot procedures and checklists for our fleet. Use them with good judgment. Dimensions: Wing Span: 112 ft 7 in Length: 129 ft 6 in Height: 41

More information

General Characteristics

General Characteristics This is the third of a series of Atlantic Sun Airways CAT C pilot procedures and checklists for our fleet. Use them with good judgment. Note, the start procedures may vary from FS9 Panel to Panel. However

More information

Ammonia Detection System Codes and Design Specifications

Ammonia Detection System Codes and Design Specifications Ammonia Detection System Codes and Design Specifications December 28, 2015 Revision 5 920 N Trade Winds Pkwy Columbia, MO 65201 Ammonia detection system codes and design specifications Following is a discussion

More information

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM SECTION 7D AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM TABLE OF CONTENTS Description and Operation... 7D- General... 7D- FATC Control... 7D- FATC Input/Output Routing Diagram...

More information

HEATER, AIR CONDITIONING AND VENTILATION

HEATER, AIR CONDITIONING AND VENTILATION 55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT

More information

Cessna Grand Caravan Pilot s Technical Examination

Cessna Grand Caravan Pilot s Technical Examination Cessna Grand Caravan Pilot s Technical Examination Version 1.0 2003-05-13 Candidate Name Licence class Private/Commercial/ATP Examiner Licence number Name Licence number Capacity Centre Date 200 -- --

More information

Interfacing Elevators with Fire Alarm and Sprinklers

Interfacing Elevators with Fire Alarm and Sprinklers Interfacing Elevators with Fire Alarm and Sprinklers IEEE Atlanta Chapter May 15, 2006 Brian K Fabel, PE Agenda Today s Codes NFPA, ASME, IBC/IFC Conflicts/Issues Tomorrow s Codes? Applicable Codes NFPA

More information

Revision Number Revision Date Insertion Date/Initials 1 st Ed. Feb 01, 00 2 nd Ed. Jun 24, 02 3rd Ed. Feb 15, 07

Revision Number Revision Date Insertion Date/Initials 1 st Ed. Feb 01, 00 2 nd Ed. Jun 24, 02 3rd Ed. Feb 15, 07 List of Effective Pages * Asterisk indicates pages changed, added, or deleted by current revision. Retain this record in front of handbook. Upon receipt of a Record of Revisions revision, insert changes

More information

A380-800 SERVICE CHECK (SV3)

A380-800 SERVICE CHECK (SV3) AIRCRAFT REGN: DATE : STN : FLT No : Page No 1 of 9 1 PRELIMINARY ITEMS 1A WARNING: Make sure that the ground safety-locks are correctly installed on the landing gear. This prevents unwanted movement of

More information

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. Tankless Electric (RTE) Troubleshooting

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. Tankless Electric (RTE) Troubleshooting Sequence of Operations 1 Power supply and field wiring block 2 Energy Cut Off (ECO) 3 Water flow plunger and cold inlet 4 Magnetic flow switch 5 Water temperature thermistor 6 Control panel and circuit

More information

Cessna Citation 500/501 Pilot s Technical Examination

Cessna Citation 500/501 Pilot s Technical Examination Cessna Citation 500/501 Pilot s Technical Examination Version 0.2 2003-09-28 Candidate Examiner Name Licence class Licence number Name Licence number Capacity Private/Commercial/ATP Centre Date 200 --

More information

Automatic air conditioning system (with the Lexus Display Audio system)

Automatic air conditioning system (with the Lexus Display Audio system) Automatic air conditioning system (with the Lexus Display Audio system) Air outlets and fan speed are automatically adjusted according to the temperature setting. To display the air conditioning operation

More information

FLYBLOCKTIME PA-28-140/160 Aircraft Type Checkout and Currency Quiz. NOTE: There may be one or more correct answers to each question.

FLYBLOCKTIME PA-28-140/160 Aircraft Type Checkout and Currency Quiz. NOTE: There may be one or more correct answers to each question. FLYBLOCKTIME PA-28-140/160 Aircraft Type Checkout and Currency Quiz Pilot s Name Date NOTE: There may be one or more correct answers to each question. 1 ) The engine in a PA-28-140/160 is a A. Continental

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

ENGINE FIRE / SEVERE DAMAGE / SEPARATION ON TAKEOFF

ENGINE FIRE / SEVERE DAMAGE / SEPARATION ON TAKEOFF ENGINE FIRE / SEVERE DAMAGE / SEPARATION ON TAKEOFF According to RYANAIR Procedures PF PM REMARKS Control the aircraft (FULL T/O thrust can be manually selected) Announce «ENGINE FAILURE» or «ENGINE FIRE»

More information

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06 A/C Performance Diagnosis Problem Warm Airflow When the Air Conditioner is On, A/C Not Working, or Poor A/C Performance (dash outlet temperature is too high) Problem Warm Airflow When the Air Conditioner

More information

Bring the fresh in. Dedicated Outside Air Systems

Bring the fresh in. Dedicated Outside Air Systems Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health

More information

The Secret of Hydraulic Schematics. BTPHydraulics www.iranfluidpower.com

The Secret of Hydraulic Schematics. BTPHydraulics www.iranfluidpower.com The Secret of Hydraulic Schematics BTPHydraulics www.iranfluidpower.com www.iranfluidpower.com Table of Contents The Secret to Reading and Interpreting Hydraulic Schematics... 1 Hydraulic System Schematics...

More information

RVH/BCH Data Centres Proposals for Surge Protection and Ventilation

RVH/BCH Data Centres Proposals for Surge Protection and Ventilation REPORT Proposals for Surge Protection and Ventilation BELFAST HEALTH AND SOCIAL CARE TRUST ROYAL GROUP OF HOSPITALS GROSVENOR ROAD BELFAST BT12 6BA Rev. 01 6th September 2013 Table of Contents 1.0 Ventilation

More information

Touareg Heating/air-conditioning system

Touareg Heating/air-conditioning system Service. Self-Study Programme 301 Touareg Heating/air-conditioning system Design and function The automobile is accompanying people more and more in their recreational time. In addition to the pure transport

More information

Why and How we Use Capacity Control

Why and How we Use Capacity Control Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,

More information

Comfort Compact Controller ZG 215N

Comfort Compact Controller ZG 215N Comfort Compact Controller ZG 215N OPERATION AND PUTTING INTO SERVICE 1 2 3 4 5 6 7 20 16 12 86 4 2 Xp 100 % 90 80 70 60 50 40 A 20...90 C 2 1,4 4 2,8 6 4,2 8 5,5 10 7,0 12 8,2 14 9,6 16 10,9 18 12,4 20

More information

MULTI-ENGINE TURBO-PROP AEROPLANE ENDORSEMENT

MULTI-ENGINE TURBO-PROP AEROPLANE ENDORSEMENT MULTI-ENGINE TURBO-PROP AEROPLANE ENDORSEMENT ENGINEERING, DATA AND PERFORMANCE QUESTIONNAIRE FOR (Aeroplane make & model) Version 1 -August 1996 Name: ARN. Endorser: ARN: (Signature/Name) 1 The endorsement

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

PC1130 Electric Air Compressor

PC1130 Electric Air Compressor Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1130 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in

More information

Compressor Service & Maintenance Manual

Compressor Service & Maintenance Manual Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance

More information

The Phaeton Heating and Air Conditioning System

The Phaeton Heating and Air Conditioning System Service. Self-Study Programme 271 The Phaeton Heating and Air Conditioning System Design and Function An outstanding climate As a luxury performance saloon, the Phaeton is fitted with a four-zone cabin

More information

Signature and ISX CM870 Electronics

Signature and ISX CM870 Electronics Signature and ISX CM870 Electronics Cummins West Training Center System Description General Information The Signature and ISX CM870 engine control system is an electronically operated fuel control system

More information

Owner s Manual RBC-AMS41E. Remote controller with weekly timer. Owner s Manual

Owner s Manual RBC-AMS41E. Remote controller with weekly timer. Owner s Manual Owner s Manual Remote controller with weekly timer RBC-AMS41E Owner s Manual Remote controller Mode d emploi Télécommande Bedienungsanleitung Fernbedienung Manuale di istruzioni Telecomando Manual del

More information

Automation at Odds. A 737 stalled when a radio altimeter malfunction caused the autothrottle and autopilot to diverge during an approach to Schiphol.

Automation at Odds. A 737 stalled when a radio altimeter malfunction caused the autothrottle and autopilot to diverge during an approach to Schiphol. Automation at Odds The pilots of a Boeing 737-800 did not heed indications of a significant decrease in airspeed until the stick shaker activated on final approach to Runway 18R at Amsterdam (Netherlands)

More information

PC1131 Electric Air Compressor

PC1131 Electric Air Compressor Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in

More information

Flight Deck Smoke Penetration Testing

Flight Deck Smoke Penetration Testing Flight Deck Smoke Penetration Testing Presented to: Systems Working Group Meeting Bremen Germany By: Date: Robert Morrison, FAA Technical Center Fire Safety May 14-15, 2014 Overview Basically a quick overview

More information

Section 5: Machine Overview

Section 5: Machine Overview Section 5: Machine Overview Machine Floor Plan Machine Specifications Sequence of Operation Theory of Operation Sensor Location Floor Plan 2007 Douglas Machine Inc. 5.1 Machine Floor Plan Figure 5.1: Machine

More information

CBD-233. Fire Alarm and Detection Systems

CBD-233. Fire Alarm and Detection Systems Page 1 of 5 CBD-233. Fire Alarm and Detection Systems Originally published August 1984. R.H.L. McEwen Fire alarm systems are normally required by building codes. In the case of new buildings, this is usually

More information

How To Clean Up A Reactor Water Cleanup

How To Clean Up A Reactor Water Cleanup General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component

More information

Operational Overview and Controls Guide

Operational Overview and Controls Guide DOCUMENT: ECSEQ2-1 EFFECTIVE: 02/14/07 SUPERSEDES: 02/26/03 Operational Overview and Controls Guide Standard Two or Three Pump Type VFD Booster Controls 6700 Best Friend Road. Norcross, GA 30071. (770)

More information

BERMAD Fire Protection

BERMAD Fire Protection Model: 400E-2M BERMAD Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Safety First BERMAD believes that the safety of personnel working with and around

More information

Dash 8 Series 400, DOT, Master Minimum Equipment List, PSM 1 84 16A.

Dash 8 Series 400, DOT, Master Minimum Equipment List, PSM 1 84 16A. E To: Distribution Date: 09 September, 2015 Subject: Dash 8 Series 400, DOT, Master Minimum Equipment List, PSM 1 84 16A. This is Revision 7 of the Dash 8 Series 400, DOT, Master Minimum Equipment List

More information

TYPE-CERTIFICATE DATA SHEET

TYPE-CERTIFICATE DATA SHEET TYPE-CERTIFICATE DATA SHEET EASA TC E.036 for Trent 1000 series engines Certificate Holder Rolls-Royce plc PO Box 31 Derby DE24 8BJ United Kingdom For Models: Trent 1000-A Trent 1000-A2 Trent 1000-AE Trent

More information

Accident Bulletin 1/2010. Date and time of accident: 13 April 2010 at 1343 hours local time (0543 UTC)

Accident Bulletin 1/2010. Date and time of accident: 13 April 2010 at 1343 hours local time (0543 UTC) Chief Inspector of Accidents Accident Investigation Division Civil Aviation Department 46 th Floor Queensway Government Offices 66 Queensway Hong Kong Accident Bulletin 1/2010 Aircraft type: Airbus A330-342

More information

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully

More information

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing ) MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing ) The Concept Maximum Heat Load Temperature Testing is a powerful air-conditioning diagnostic and evaluation technique. It is also

More information