1 REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS USING THE REMOTE CONTROL UNIT...3 OPERATION Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read this operating instruction carefully and keep it for future reference /02
2 PRECAUTIONS DISPLAY Information are displayed when the remote control unit is switched on. Operation Mode Automatic Heating Cooling Fan only Dehumidification (dry) Displayed when data trasmitted Or remote control unit lock Shows the type of timer Clock (hours and minutes) Displayed when the timer on is set and activated Displayed when the timer off is set and activated Displayed in Sleep Mode Operation Set temperature or room temperature Displayed when the temperature is the room temperature Indicate that the air conditioner is operating in I FEEL mode Automatic horizontal air flow oscillation switched on (option) Automatic flap oscillation switched on Fan speed indication Automatic fan speed Low speed Medium speed High speed ON/OFF OPERATION BUTTON This button turns the air conditioner ON and OFF. MODE SELECTOR BUTTON Press this button to modify the air conditioner mode. (automatic) When this setting is selected, the air conditioner calculates the difference between the thermostat setting and the room temperature and automatically switches to the "cool" or "heat" mode. (heating) The air conditioner makes the room warmer. dehumidification (dry) The air conditioner reduces the humidity in the room. (cooling) The air conditioner makes the room cooler. (fan) The air conditioner circulate the air. COOL / DRY / HEAT / FAN Models SLEEP BUTTON For details, see "Sleep mode". When you press this button in the COOL, HEAT or DRY mode, the mark appears on the display and the microcomputer in the remote control unit will adjust the set temperature to save energy. 1
3 TRANSMITTER When you press the buttons of the remote control unit, the mark appears on the display to transmit the setting changes to the receiver in the air conditioner. SENSOR Atemperature sensor inside the remote control unit detects the room temperature. TEMPERATURE SETTING BUTTONS - (cooler) Press this button to decrease the set temperature. + (warmer) Press this button to increase the set temperature. FAN SPEED SELECTOR BUTTON Fan speed is automatically selected by the microcomputer. Low speed. Medium speed. High speed. SET BUTTON Push this button to select the functions: set the present time set the ON-OFF timer For detail see "HOW TO SET THE PRESENT TIME"and "SETTING THE TIMER". TIMER AND PRESENT TIME SETTING BUTTONS Pushing + or - buttons the setting of the time and timer can be activated. For detail see "HOW TO SET THE PRESENT TIME" and "SETTING THE TIMER". TIMER BUTTON (timer setting) Push the TIMER on the display starts the timer ON and OFF setting procedure. For detail see "SETTING THE TIMER". LOCKING THE REMOTE CONTROL Pushing this button freezes the last operation setting.when is activated the remote control will not be able to control the air conditioner. To release the lock status push again. TEMPERATURE SENSOR SELECTOR Push IFEEL button to activate the temperature control in the remote control unit. This function provides a more confortable temperature control. ROOM TEMPERATURE Push the ROOM button to show the actual room temperature around the remote control. FLAP SPEED SELECTORS Press this button to select the desidered flap sweep function. : The flap moves up and down automatically. : Every time you push the button the flap moves one step. TIMER RESET Push the CLEAR button to cancel all timer setting. 2
4 USING THE REMOTE CONTROL UNIT HOW TO INSTALL BATTERIES Remove the lid in the rear part of the remote control unit. Insert two AAA alkaline batteries of 1,5 V-DC. Make sure the batteries point in the direction marked in the battery compartment. The batteries last about six months. Depending on how much you use the remote control unit. Remove the batteries if you do not use the remote control unit for more than one month. Press the +, -, SET and CLEAR buttons together after batteries replacement. (This operation allows you to reset correctly all the programs. The remote control unit is to be set up again). Replace the batteries when the remote control unit lamp fails to light, or when the air conditioner does not receive the remote control unit signals. The batteries of the remote control contain polluted substances exhausted batteries must be disposed according to the laws in force. OPERATION WITH THE REMOTE CONTROL UNIT Check that the circuit breaker on the power panel is turned ON and the STANDBY lamp is light up. When using the remote control unit, always point the unit transmitter head directly at the air conditioner receiver. HOW TO TURN ON THE AIR CONDITIONER Press the ON/OFF button to turn the air conditioner on. The indicator OPERATION will light up, indicating the unit is in operation. TEMPERATURE SENSOR SELECTOR Under normal conditions the room temperature is detected and checked by the temperature sensor placed in the air conditioner. Press the remote control I FEEL button to activate the temperature sensor placed in the remote control. This function is designed to provide a personalised environment by transmitting the temperature control command from the location next to you. Therefore, in using this function, the remote control should always be aimed, without obstruction, at the air conditioner. The remote control unit sends the temperature signal to the air conditioner regularly at two minute intervals. If the signal from he remote control unit stops for more than five minutes due to some troubles, the air conditioner will switch to the temperature ensor which is built into the indoor unit and controls the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected in the air conditioner position. REMOTE CONTROL UNIT DISPLAY 3
5 HOW TO SET THE PRESENT TIME 1. Press the SET button for five seconds. The time indication alone flashes. 2. Press the + or - buttons until the present time is displayed. 3. Press the SET button to stop the indication flashing. COOLING Verify that the unit is connected to the main power and the STANDBY lamp is light up. 1. Set the MODE selector to COOL. 2. Press the ON/OFF button and switch the airconditioner ON. 3. Press the TEMP. buttons to set the desired temperature (the temperature range is between 30 C max. and 16 C min.). THE DISPLAY SHOWS THE SELECTED TEMPERATURE. 4. Press the FAN SPEED button to select the fan speed. 5. Press the FLAP buttons and adjust the air flow direction as desired(see adjustment of air flow). Make sure that the remote control is switched on. 4. Press the FAN SPEED button to select the fan speed. 5. Press the FLAP buttons and adjust the air flow direction as desired(see adjustment of air flow). Make sure that the remote control is switched on. For several minutes after the start of heating operation, the indoor fan will not run until the indoor heat exchanger coil has warmed up sufficiently. This is because the COLD DRAFT PREVENTION SYSTEM is operating. DEFROSTING OF HEAT EXCHANGE OUT DOOR UNIT STANDBY When the outdoor temperature is low, frost or ice may appear on the heat exchanger coil, reducing the heating performance. When this happens, a microcomputer defrosting system operates. At the same time, the fan in the indoor unit stops and the OPERATION lamp is flashing until defrosting is completed. Heating operation restarts after several minutes. (This interval will vary slightly depending on the room and outdoor temperature). HEATING PERFORMANCE A heat pump conditioner heats a room by taking heat from outside air. The heating efficiency will fall off when the outdoor temperature is very low. If enough heat is not obtained with this air conditioner, use another heating appliance in conjunction with it. HEATING 1. Set the MODE selector to HEAT. 2. Press the ON/OFF button and switch the air condioner ON. 3. Press the TEMP. buttons to set the desired temperature (the temperature range is between 30 C max. and 16 C min.). THE DISPLAY SHOWS THE SELECTED TEMPERATURE. 4
6 AUTOMATIC OPERATION 1. Set the MODE selector to AUTO. 2. Press the ON/OFF button and switch the air condioner ON. 3. Press the TEMP. buttons to set the desired temperature (the temperature range is between 30 C max. and 16 C min.). DEHUMIDIFYING (DRY) 1. Set the MODE selector switch to DRY. 2. Press the ON/OFF button and switch the air condioner ON. 3. Press the TEMP. buttons to set the desired temperature (the temperature range is between 30 C max. and 16 C min.). THE DISPLAY SHOWS THE SELECTED TEMPERATURE. THE DISPLAY SHOWS THE SELECTED TEMPERATURE. When this setting is selected, the air conditioner calculates the difference between the thermostat setting and the room temperature and automatically switches to the COOL or HEAT mode as appropriate. 4. Switch the FAN SPEED selector button to the setting you want. Example of operation diagram in the (Auto) mode with the set room temperature at 23 C. Use DRY operation when you want to reduce the humidity in the room. Once the room temperature reaches the set level, the unit repeats the cycle of turning on and off automatically. During DRY operation, the fan speed is automatically set to low or stops to prevent overcooling. Dry operation is not possible if the indoor temperature is 15 C or less. FAN ONLY If you want to make air circulate without any temperature control, follow these steps: The air conditioner changes the operation mode (from cool to heat), if one of the following conditions occurs: - ZONE A: changes if the difference between the room temperature and the temperature set on the remote control unit is at least 3 C.. - ZONE B: changes if the difference between the room temperature and the temperature set on the remote control unit is at least 1 C, one hour after the compressor stop. - ZONE C: never changes if the difference between the room temperature and the temperature set on the remote control unit is no more than 1 C. 1. Set the MODE selector switch to FAN. 2. Press the ON/OFF button and switch the air conditioner ON. 5
7 ADJUSTING THE FAN SPEED AUTOMATIC Simply set the FAN SPEED selector to the position. A microcomputer automatically controls the fan speed when the AUTO mode is selected. When the air conditioner starts operating, the difference between the room temperature and the set temperature is detected by the microcomputer which then automatically switches the fan speed to the most suitable level. In FAN Only mode the fan speed is adjusted automatically as in cooling mode. WHEN DIFFERENCE BETWEEN ROOM TEMPERATURE AND SET TEMPERATURE IS Cooling and dehumidifying modes: Heating mode: FAN SPEED 2 C and over High Between 2 and 1 C Medium Below 1 C Low 2 C and over High Below 2 C Medium The above mentioned data make reference to the conditioner operating when the sensor on the remote control unit is ON. If the sensor on the indoor unit is being used then actual operation will slightly differ from that described in the above tables. MANUAL SLEEP MODE The SLEEP mode enables you to save energy. 1. Set the MODE selector to cool, dry or heat. 2. Press the SLEEP button. 3. The mark appears on the display. Press the SLEEP button again to release the SLEEP function. What does the SLEEP mode mean? In this mode, the air conditioner will cool or heat the room to the set temperature, and then the thermostat will make the unit pause. After about 1 hour, the air conditioner will automatically reset the set temperature as follows (also refer to graphs). OPERATING MODE SET TEMPERATURE CHANGE Heating Lowered by 1 C Cooling and Dehumidifying Raised by 1 C When the room temperature reaches the new set value, the thermostat will cause the unit to pause. After about 1 hour the temperature will be raised by 1 C in cooling, or lowered by 1 C in heating. This enables you to save energy without sacrificing your comfort. COOLING AND DEHUMIDIFYING Setting temperature Room temperature If you want to manually adjust speed just set the FAN SPEED selector as desired. Each time the button is pressed, the fan speed is changed in sequence: 1 hour 1 hour TIME (Lo) (Med) (Hi) (AUTO) Setting temperature HEATING Room temperature 1 hour 1 hour TIME 6
8 I FEEL TEMP FUNCTION OPERATION Press button IFEEL to activate the IFEEL function. Thermometer sign will appear on the LCD operation display. Select suitable temperature setting. Make sure that the remote control unit is aimed at the air conditioner, with the IFEEL sensor in front. Prevent the IFEEL sensor from being affected by heat sources such as lamps, heaters, direct sun, etc. or from being directly affected by the air conditioner air flow. These may cause the sensor to transmit the wrong temperature data, thereby disturbing the performance of the IFEEL function. ROOM TEMP FUNCTION OPERATION Press the ROOM button to show the actual room temperature around the remote control unit. The measured room temperature and the room temperature sign will be displayed. To cancel the ROOM Temperature display press on one of the following: Press again on ROOM Temperature button. Change of MODE button. Room temperature range is between 6 and 36 in 1 increments. Display should show "HI" or "LO" to represent temperature that is above 36 or below 6. LOCK FUNCTION By pressing LOCK button, the remote control will lock the last operation program. All the function buttons will be inoperative, including START/STOP button. By pressing LOCK button again the remote control will be released from its locked position. When lock mode is functioning, the transmission sign will be on. SETTING THE TIMER There are four timers that can be selected on the remote control.two daily timers (designated as T1,T2),and two optional weekend timers (designated as WKTI, WKT2).Each timer can be selected by pressing TIMER button. The daily timers T1 and T2 can be set for ON and OFF separately for two different time periods. Timer setting will not change until new setting is input. The weekend timers WKT1 and WKT2 can be set for ON and OFF separately for two different time periods and they are effective two days only. These timers will be effective on the day of setting and on the day after only. At 24:00 on the second day, the WK timer will not be effective anymore and the daily timer will be effective again. WKTI - effective on the setting day WKT2 - effective one day after the setting day. : 1. During the weekend timer operation, the daily timers will be disabled. 2. The WK timers must be reactivated before every weekend. A) HOW TO SET THE ON TIME 1. Press the TIMER button to select the desired timer. 2. Press the SET button till the ON sign blinks. 3. Press the + or - (HOUR) button until the desired value is displayed. 4. Press the SET button to activate the timer. B) HOW TO SET THE OFF TIME 1. Press the TIMER button to select the desired timer. 2. Press the SET button till the OFF sign blinks. 7
9 3. Press the + or - (HOUR) button until the desired value is displayed. 4. Press the SET button to activate the timer. ADJUSTING THE AIR FLOW DIRECTION HORIZONTAL (manual) The horizontal air flow can be adjusted by moving the vertical vanes to the left or right. C) HOW TO SET A PROGRAM FOR DAILY ON/ OFF OPERATION 1. Press the TIMER button to select the desired timer. 2. Press the SET button till the ON sign blinks. 3. Press the + or - (HOUR) button until the desired value is displayed. 4. Press the SET button again, the OFF sign blinks. 5. Press the + or - (HOUR) button until the desired value is displayed. 6. Press the SET button to activate the timer. VERTICAL (with remote control unit) The remote control gives you the possibility to control the flap in two way: 1. Push the button to start the flap sweep. If you push again the flap stops immediately. 2. push the button to move the flap step by step. Or activate the horizontal air flow option is selectable via switch. Set vertical vanes to the front position during COOLING/DRY operation if humidity is high. If the vertical vanes are set to the left-most or right-most position, condensation will form around the air outlet and drip off. D) HOW TO CLEAR THE TIMER 1. Press the TIMER button to select the timer. 2. Press the CLEAR button if you want that every timer operation will be cleared. Do not move the flap with your hands when the air conditioner is running. If the procedure to set the timer is not completed, by pushing the SET button, within 15 seconds the timer operation will be cancelled and the last set-up is restored. S The flap automatically closes when the unit is off. During the heating operation, the fan speed will be very low and the flap will be in the horizontal position until the air being blown out of the unit begins to warm. Once the air warms up, the flap position and fan speed change to the settings specified with the remote control. 8
10 Use the FLAP button on the remote control to adjust the position of the flap. If you move the flap by hand, the factual flap position and the flap position on the remote control may no longer match. If this should happen, shut off the unit, wait for the flap to close, and then turn on the unit again; the flap position will now be normal again. Do not have the flap pointed down during cooling operation. Condensation may begin to form around the air vent and drip down. S Some functions of remote controller will not be available when the unit does not support them! 9
OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump
R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully
SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify
Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
CS488-R51I13A 202055000038 20130226
AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION AM-6CPR(N) The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL
OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex
OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex Version C Single, Dual, Tri or Quad Zone Ductless Mini-Split System Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com
OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER. G Series Cooling
OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER G Series Cooling A O W N E R S MANUAL Thank you for selecting Carrier! You can be justifiably proud of your purchase because the same pride in craftsmanship
Single Zone LCD Thermostat Operating Instructions
Fan Cool Furnace *Heat Pump or Heat Strip On/Off F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX Cool/Furnace 3313193.XXX Cool/Furnace/Heat Pump 3313194.XXX Cool/Furnace/Heat Strip
Owner s Manual RBC-AMS41E. Remote controller with weekly timer. Owner s Manual
Owner s Manual Remote controller with weekly timer RBC-AMS41E Owner s Manual Remote controller Mode d emploi Télécommande Bedienungsanleitung Fernbedienung Manuale di istruzioni Telecomando Manual del
LG Wireless Remote Controller
Visit us at : http://www.lgservice.com LG Wireless Remote Controller Owner's & Installation Manual Models: PQWRHSF0 PQWRCSF0 LG ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH IMPORTANT Please read this installation
and using this appliance and keep this manual for future reference.
Thank you very much for purchasing this Air Conditioner. Please read this use and installation instructions carefully before installing and using this appliance and keep this manual for future reference.
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
DUCT TYPE AIR CONDITIONER
OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES AIR CONDITIONER DUCT TYPE English Deutsch
To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)
OPERATION MANUAL Split System Ducted Air Conditioner To suit Daikin FDY "F" Series and FD "F" Series AIR CONDITIONER A hr o C (and other models incorporating BRC1B62/52 Remote Controller) Dear Owner, Thank
SERVICE MANUAL INDOOR UNIT
SPLIT-TYPE AIR CONDITIONERS Revision E: MSZ-GE22VAD- A1 has been added. Please void OBH531 REVISED EDITION-D. INDOOR UNIT SERVICE MANUAL. OBH531 REVISED EDITION-E Models MSZ-GE22VA - A1 MSZ-GE50VA - A1
AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CS457-R14A 202055090318 20110215
AIR CDITIER REMOTE CTROLLER ILLUSTRATI CS5-RA 005500 005 Thank you very much for purchasing our air conditioner Please read this owner's manual carefully before using your air conditioner CTENTS Handling
INDOOR UNIT/OUTDOOR UNIT
SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT MODEL RAS-60YHA/RAC-60YHA OUTDOOR UNIT INDOOR UNIT RAC-60YHA RAS-60YHA Instruction manual Page 1~26 To obtain the best performance and ensure years of
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
AIR CONDITIONER (SPLIT TYPE)
OWNER S MANUAL AIR CONDITIONER (SPLIT TYPE) For general public use ENGLISH EN Indoor Unit RAS-07PKVP-E RAS-10PKVP-E RAS-13PKVP-E RAS-16PKVP-E RAS-18PKVP-E RAS-07PKVP-ND RAS-10PKVP-ND RAS-13PKVP-ND RAS-16PKVP-ND
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. www.lg.
ENGLISH FRANÇAIS ESPAÑOL OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : Room Air Conditioner P/NO : 3828A20434H www.lg.com
Split Type Room Air Conditioner. KSWM units
OWNER S MANUAL Split Type Room Air Conditioner KSWM units Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.
LG Room Air Conditioner OWNER'S MANUAL
website http://www.lg.ca LG Room Air Conditioner OWNER'S MANUAL LG Prior to installation, this airconditioning unit must be submitted for approval by the utility service which provides electricity (EN
WINDOW ROOM AIR CONDITIONER
WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please
OPTIONAL SLENDER REMOTE CONTROL
DAIKIN ROOM AIR CONDITIONER Operation Manual OPTIONAL SLENDER REMOTE CONTROL BRC944A2B READ BEFORE OPERATION Safety Precautions...2 Names of Functions of Parts...4 Preparation before Operation...5 OPERATION
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner * Shows U1 type Model No. Indoor Units Type Indoor Unit Type 26 36 42 Remarks U1 4-Way Cassette S-26PU1U6 S-36PU1U6 S-42PU1U6 with Wired Remote Controller:
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
AIR CONDITIONER WALL CONTROLLER
AIR CDITIER WALL CTROLLER Operating Instructions Controller Model Numbers LM7 LM7-D LM4 Please Read This Manual Congratulations on your purchase of an ActronAir air conditioning system. This unit has been
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
Contents. Correct Disposal of This Product (Waste Electrical & Electronic Equipment)
Contents PREPARATION Safety Precautions... 3 Name of Each Part... 8 Remote Control Buttons and Display... 10 Inserting the Remote Control Batteries... 11 Getting Started... 12 OPERATION Selecting Auto
WALL MOUNTED SPLIT TYPE AIR CONDITIONER
WALL MOUNTED SPLIT TYPE AIR CONDITIONER MANUAL 8 OM-G12-ACSON CONTENTS - Operating Guide page 1 - G12 Remote Controller Indication page 2 - Indicator Lights page 4 - Installation of Aroma page 5 - Auto
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL Thank you for choosing our Air Conditioner. Please read this OWNER'S MANUAL carefully prior to use and keep it for further reference. CONTENTS Contents
Taurus Series YORK Window Air Conditioners
Taurus Series YORK Window Air Conditioners IOM IOWRCAG50220711A1 Warning 1. Before using the Air conditioner please read the instructions carefully. They contain important advise about the installation,
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
AIR CONDITIONER Duct Type OPERATING MANUAL
AIR CONDITIONER Duct Type OPERATING MANUAL KEEP THIS MANUAL FOR FUTURE REFERENCE P/N9374379460 CONTENTS SAFETY PRECAUTIONS... 1 FEATURES AND FUNCTIONS... 3 NAME OF PARTS... 4 PREPARATORY OPERATION... 5
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
LG Multi Type Air Conditioner
LG Multi Type Air Conditioner OWNER'S MANUAL LG Prior to installation, this airconditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-2, EN 61000-3
HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL
TWD-0813-033 Neo Manual REV:Layout 1 9/27/13 11:13 AM Page 1 GREE ELECTRIC APPLIANCES, INC. www.greecomfort.com LIMITED WARRANTY GREE distributor (hereinafter Company ) warrants this product against failure
DAIKIN ROOM AIR CONDITIONER MODELS. Operation Manual ENGLISH ESPAÑOL TURKISH
DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS FT50GAVEA FT60GAVEA FTY50GAVA FTY60GAVA ENGLISH ESPAÑOL TURKISH CONTENTS READ BEFORE OPERATION Safety Precautions... Names of Parts Indoor unit, Opening
evo + HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL Models: GWH09AB-D3DNA2D GWH18AC-D3DNA2D GWH24AC-D3DNA2D
evo + HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL Models: GWC09AB-D3DNA2D GWC12AB-D3DNA2D GWC18AC-D3DNA2D GWC24AC-D3DNA2D GWH09AB-D3DNA2D GWH12AB-D3DNA2D GWH18AC-D3DNA2D GWH24AC-D3DNA2D
Operating Instructions Air Conditioner
P07-T10130 Operating Instructions Air Conditioner Indoor Unit CS-F24DD1E5 CS-F28DD1E5 CS-F34DD1E5 CS-F43DD1E5 CS-F50DD1E5 Outdoor Unit Inverter Model (HBE5 Series) CU-YL24HBE5 CU-YL28HBE5 CU-YL34HBE5 CU-YL43HBE5
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
Operating Instructions Air Conditioner
F566272 Operating Instructions Air Conditioner CS-C18FFH CS-C28FFH CU-C18FFH CU-C28FFH ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
HIGH-WALL DUCTLESS AIR CONDITIONING SYSTEM
HIGH-WALL DUCTLESS AIR CONDITIONING SYSTEM Models: GWC09MA-A3DNA3A GWC12MB-A3DNA3A GWC09MB-D3DNA3D GWC12MB-D3DNA3D GWC18MC-D3DNA3D GWC24MD-D3DNA3D GWC30LB-D3DNA3E GWC36LB-D3DNA3A Thank you for choosing
Air Conditioner. Portable. 10000 BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN002908. Important! Please read these instructions carefully.
Warranty Arlec guarantees this product in accordance with the Australian Consumer Law. Arlec also warrants to the original first purchaser of this product ( you ) from a retailer that this product will
Remote Controller Manual
VMFI- / VMFO- Floor Standing Unit Remote Controller Manual Thank you for choosing INVENTOR air conditioning system. For correct use of this unit, please read this manual carefully and keep it for future
USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL
USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
Inverter Single Zone Ductless Mini Split Heat Pump
WNER S MANUAL Inverter Single Zone Ductless Mini Split Heat Pump VMH 30/36 Series Version C Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com wner s Manual
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS PARTS LIST Front Back FIG.5 FIG.6 1. Control panel 2. Carrying handle 3. Water tank 4. Casters
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
Split Air Conditioner
Split nditioner plit itsplit ir onditioner Split Split Split Split Split User s WNER'S 'S ER'S For s: AWI/AWO-21HPR1 Delta AWI/AWO-25HPR1 Delta AWI/AWO-32HPR1 Delta AWI/AWO-53HPR1 Delta AWI/AWO-65HPR1
Owner s Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E. Model name:
AIR CONDITIONER (SPLIT TYPE) Indoor Unit Not accessible to the general public Model name: 4-way Air Discharge Cassette Type RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E Air conditioner (Split
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
ELECTRIC POSITION for electric heat, then confirm with Fan Test below.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
New Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
INSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE
AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. www.lg.
OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED P/NO : MFL67657205 www.lg.com ITALIANO ESPAÑOL FRANÇAIS
Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER
Before using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT- TYPE ROOM AIR CONDITIONER Read This Manual Inside you will find many helpful hints on how to
The figures in this manual may be different with the material objects, please refer to the material objects for reference.
CONTENTS Operation and maintenance Notices for operation Notices for use Names and functions of each part Operation of wireless remote control Emergency operation Clean and care Troubleshooting Installation
OPERATING INSTRUCTIONS INDOOR UNIT MSZ-GA50VA MSZ-GA60VA MSZ-GA71VA MSZ-GA80VA
SPLIT-TYPE AIR CONDITIONERS OPERATING INSTRUCTIONS INDOOR UNIT MSZ-GA50VA MSZ-GA60VA MSZ-GA71VA MSZ-GA80VA For customers Thank you very much for purchasing this Mitsubishi room air conditioner. To use
Split Air Conditioner
Change for Life Split Air Conditioner Owner's Manual Residential Air Conditioners MODEL: GWH09MA-A3DNXXA GWC09MA-A3DNXXA GWH12MB-A3DNXXA GWC12MB-A3DNXXA GWH09MB-D3DNXXD GWC09MB-D3DNXXD GWH12MB-D3DNXXD
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0
Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view
Gree Solar Hybrid Hi Wall Inverter Air Conditioner
Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar
RCS-TM80BG. Contents 4. Weekly Program Function... EG-6 5. Outing Function... EG-12 6. Sleeping Function... EG-14 XXX XXXX XXXX XXXX XXXX
Save These Instructions! Save These Instructions! Save These Instructions! Save These Instructions! Save These Instructions! Save These Instructions! Save These Instructions! 1. Important Safety Instructions...
SERVICE MANUAL INDOOR UNIT
SPLIT-TYPE AIR CONDITIONERS Revision B: "How to check miswiring and serial signal error" for MUZ type has been added. The description about "Low standby power control" has been added to "TECHNICAL CHANGES".
SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
Technical service manual 2009
MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS Technical service manual 2009 KSIM MULTI ZONE SERIES R410A DC Inverter multi Series Models KSIM20912-H216 KSIM30912-H216 KSIM40912-H216 CONTENT 1. Product features
HEAT HEAT COOL HEAT PUMP COOL
OWNER S MANUAL RESIDENTIAL THERMOSTAT P/N P374-1800 HEAT COOL HEAT PUMP Su AUTO 0I20: Pm 74 COOL HEAT 27 7-DAY MABLE DIGITAL THERMOSTAT 3 Configurable Outputs Accepts Optional Humidity Module: Control
OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO
English AIR CONDITIONER Compact Wall Mounted Type OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO Français Español KEEP THIS OPERATING MANUAL FOR FUTURE REFERENCE CONSERVER CE MANUEL D UTILISATION
LG Room Air Conditioner OWNER'S MANUAL
Visit us at http://www.lgservice.com LG Room Air Conditioner OWNER'S MANUAL Dear Owner Thank you for installing LG air conditioner. Your best choice guarantees you a great performance and service to make
AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. www.lg.
SVENSKA NORSK SUOMI DANSK OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED P/NO : MFL67641301 www.lg.com
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE
Portable Evaporative Air Cooler for Indoor Use OWNER S MANUAL Read and save these instructions before use Model: CL25AE Power rating: 230 Watts Voltage rating: 120 Volt AC, 60Hz For product inquiries or
your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump
your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump Your new Daikin Altherma heat pump In this manual you will find information and guidelines that
Room Air Conditioners
User Manual Room Air Conditioners R410A Split Type Y Series DC INVERTER ECO940SD ECO120SD ECO1840SD Please read this installation manual completely before installing the product. When the power cord is
OMI-09/OMO-09 OMI-12/OMO-12 OMI-18/OMO-18 OMI-24/OMO-24. Wall Mounted Unit
OMI-09/OMO-09 OMI-12/OMO-12 OMI-18/OMO-18 OMI-24/OMO-24 Wall Mounted Unit CONTENTS SAFETY PRECAUTIONS Warning...3 Caution...4. NAMES OF PARTS Indoor unit......5 outdoor unit...5 Indication lamp...5 OPERATING
SERVICE & MAINTENANCE MANUAL
SERVICE & MAINTENANCE MANUAL 2005 TABLE OF CONTENTS PAGE NO. 1. Precautions for Service & Maintenance 2 2. Split System Description 3 3. Unit Model Designation & Identification 4 4. Unit Models & Part
OPERATING INSTRUCTIONS INDOOR UNIT MSZ-A18YV MSZ-A24YV MSZ-A26YV MSZ-A30YV
SPLIT-TYPE AIR CONDITIONERS OPERATING INSTRUCTIONS INDOOR UNIT MSZ-A18YV MSZ-A24YV MSZ-A26YV MSZ-A30YV For customers Thank you very much for purchasing this Mitsubishi room air conditioner. To use this
its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
A/C-HEATER SYSTEM - AUTOMATIC
A/C-HEATER SYSTEM - AUTOMATIC 1995 Volvo 850 1995-96 Auto. A/C-Heater Systems Volvo 850 * PLEASE READ THIS FIRST * WARNING: To avoid injury from accidental air bag deployment, read and carefully follow
Features of your Air to water heat pump
Features of your Air to water heat pump Running Costs-Reduction of Up to 33.3% Samsung EHS, known for its world class efficiency (12kW floor heating system with COP of 4.60), can reduce 33.3% of your running
CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?
WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?...an explanation for householders A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set On and Off time periods
SERVICE MANUAL INDOOR UNIT MSZ-EF35VEW MSZ-EF22VEB - - E1 MSZ-EF25VEB E1 MSZ-EF35VEB - - E1 MSZ-EF35VEB E1 MSZ-EF35VES - E1 - E1 MSZ-EF22VEW -
SPLIT-TYPE AIR CONDITIONERS Revision A: Airflow in the Silent mode in the cooling operation has been changed. "TROUBLESHOOTING" has been corrected. Please void OBH589. INDOOR UNIT SERVICE MANUAL. OBH589