BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET



Similar documents
Generator DoCKInG StatIonS

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Mini Power-Zone Unit Substation

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

TERMINATION ENCLOSURE OPTIONS

ASCO SERIES 185 Power Transfer Switches

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

Sample - No Commercial Use

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Secondary Unit Substations

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

NEC 2014 Code Changes

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Electrical Code Regulation

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

INSTALLATION INSTRUCTIONS

SECTION LOW VOLTAGE LIGHTING CONTROLS

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

The following components are common to most cubicles; this example is an ABB HK cubicle.

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

IRRIGATION PUMPING Table of Contents - Section 900

A. Shop Drawing submittals shall include, but not be limited to, the following:

Utility Distribution Systems

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

Temporary Power Outlet Panels

Low Voltage Switchgear

Type 1, 3, & 3R Enclosures

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

MCC Ratings. Voltage Rating

Magnum Mobile Generator MMG55 Specifications

Transfer Switch 30 Amps STS-30. Manual. Please read this manual before operating your transfer switch

LVA Take Offs in Bid Manager

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

SWITCHGEAR. EGP Switchgear

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

June July 18, of 7

Hyperlinks are Inactive

SECTION SWITCHBOARDS

Contractors Guide Central Inverter System Installation

Top Commercial / Residential Electrical Requirements *

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Rugged & Reliable Power Connections

Bypass transfer switch mechanisms

Section 10 Electric Switchboards: 0 Through 600 Volts

ELECTRICAL INSPECTION BULLETIN (Effective )

City of Riverside Building & Safety Division Phone: (951)

Generator Transfer Switch Model # HTS15-AUTO

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

JIC CONTINUOUS HINGE BOXES

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Mobile Data Power Model: MDP-25

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE

Testing Accessories. Test PaddleS. Insulated Socket Wrench Jumper Strips Test Lead Kit. Test Paddle Attachment Clips Plugs Binding Posts

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

APC 3Phase Power Distribution

USA: 866.LAWSON4U ( ) Canada: lawsonproducts.com. Electrical Industrial and Fleet Solutions

CHAPTER 5 PARTS. This chapter describes assemblies / subassemblies / parts considered replaceable at on-site field installation.

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

EDS / EFS Series Control Stations

Electrical Grounding. Appendix C

Parallel Redundant Uninterruptible Power Supply

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

SECTION TELECOMMUNICATION ROOMS

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

Electrical. This section applies to the design and installation of building power distribution systems.

Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants

SAF-T-LINER MVP-EF PARTS MANUAL. Electrical Section. Page 7-1. Electrical 10/96

Transcription:

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service entrance equipment. Whether during a long-term utility outage or planned facility maintenance, our cabinet will help you easily establish a connection to back-up power when time is of the utmost importance. Berthold Electric www.genconcab.com 800.657.6650

Constructed of rugged, corrosion-resistant Aluminum or Stainless Steel, the Berthold Electric Generator Connection Cabinet can be ordered in either a wall mount or pad mount design. The cabinet is designed to maintain a NEMA 3R rating, even with the portable generator cables connected, with the standard bolted construction. For applications requiring an even higher degree of weather protection and strength, cabinets can be continuously seam welded. Doors are attached with a continuous hinge, incorporate stiffeners, and are held closed with weather resistant latches. On both cabinet designs, the generator cable connection access panel is held in place by the main door so that the connection point can only be accessed if the main door is unlocked and opened by a qualified technician. Wall mount cabinets have external mounting ears for easy installation; Pad mount cabinets are supported on an aluminum channel base, providing a location for anchoring the cabinet to the concrete pad. The cabinet interior is constructed with silver-plated copper bus, rated at 1000A/square inch current density, with ample cable bending space provided for permanent connections. The bus is mounted on insulators that are securely fastened to the enclosure walls. Generator connections are typically made with factory installed Crouse-Hinds color-coded E1016 series Cam-Lok connectors or mechanical set screw lugs. Permanent connection cables to the facility s service equipment are secured with long barrel crimp lugs or mechanical set screw lugs. Electrical Features: Sizes from 400 to 3200 Amps. Available System Voltage rating up to 600 Volts. Mechanical Set Screw Lugs, Long Barrel Compression Lugs, or Punching only available for Permanent Connections. Mechanical Set Screw Lugs or Crouse Hinds E1016 Series color coded Cam-Lok Connectors available for Generator Connections. Silver-plated copper bus rated at 1000A per square inch current density. Mechanical Features: Wall mount or pad mount design. NEMA 3R Aluminum or Stainless Steel Construction. Lockable Latch for front door. Access Panel for Portable Generator/Load Bank connection held closed by door when not in use. Drip Hood. Berthold Electric www.genconcab.com 800.657.6650

AVAILABLE OPTIONS Convenience outlet provision: The cabinets can be provided with outlet boxes for wiring in up to four-gang outlets. These outlet boxes would typically be energized by the preferred or utility source to provide a convenient location to plug in drop lights, tools, or the portable engine block heater and battery charger. Access panel interlocking micro-switches: When the switch is wired to the shunt trip on the permanent engine breaker or the utility service main breaker, it serves to prevent asynchronous connection of the two sources. Shunt tripping the preferred source prevents the generator connection cabinet from being back-fed, thus ensuring the cabinet is de-energized when personnel are making connections. Wall Mount TOP MOUNTING EARS OPEN FOR EASY WALL MOUNT INSTALLATION DRIP HOOD WITH SLOPED TOP TO ENSURE WATER RUNOFF 38 18 Key interlock provision: Prevents access to portable engine connection compartment unless key is present. Key is held captive when door is open. 33 38 Provision Only: Customer to supply and install Kirk Key Interlock Model #KDLO---1E or Superior Interlock Model #B- 5003-1. Phase Sequence and Failure Indication Phase Sequence and Failure Indication can be provided to ensure that the temporary engine is connected with the same phasing as the utility source. 39 3/4 CAM-LOK CONNECTORS ARE RECESSED UNDER ENCLOSURE FOR SAFETY AND TO ENSURE WEATHER RESISTANCE APPROXIMATE WEIGHT 180lbs BOTTOM ACCESS PANEL IS HELD CLOSED UNTIL FRONT LOCKABLE DOOR IS OPENED Indication is provided by a Crompton Phase Sequence and Failure Meter. Cam-Lok Snap Covers Cam-Lok generator connection points can be covered with a spring-closed metal cover for added safety. Cam-Lok Black Rubber Caps Cam-Lok generator connection points can be covered with a weather resistant rubber cap for added protection and safety when all connection points are not in use. Welded Construction Either cabinet style can be fabricated using continuously seam welded construction for increased durability and weather resistance. All welds are finished and ground smooth. Choose this option for a NEMA 4X style construction. Cabinet Finish All cabinets come with standard Bare Aluminum Finish. Optional Finishes include Powder Coated Gray or Stainless Steel for added durability.

LOAD BANK APPLICATION NOTES PORTABLE GENERATOR BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET UTILITY SERVICE ENTRANCE The Berthold Electric Generator Connection Cabinet can be used in several supply or load power configurations. Highlighted in this diagram is the Generator Connection Cabinet ready to be fed from the portable generator if temporary back-up power is needed while the permanent generator is out of service. SHUNT TRIP OR KEY INTERLOCK (Optional) TRANSFER SWITCH MAIN SWITCHBOARD Additional applications can include using a portable generator as the sole auxiliary source connected through our cabinet to feed a transfer switch or back-feed a circuit breaker on service equipment. STATIONARY PERMANENT ENGINE GENERATOR 3000AF 2000AT 3000AF 2600AT 800AF 600AT 800AF 600AT The Berthold Electric Generator Connection Cabinet also can act as a convenient point to attach load banks for routine generator runs. See www.genconcab.com for application configurations. Generator connection cabinets suggested specifications Enclosure shall be provided with SouthCo lockable latches on front door, and an independent access panel door. Access panel shall not open unless main lockable door has been opened. Internal bus shall be sized for 1000A/sq. in. ampacity, and Pad Mount bus work shall be supported with UL Recognized Component (QEUY2) insulators. DRIP HOOD WITH SLOPED TOP TO ENSURE WATER RUNOFF Enclosures shall be either stand alone pad mount or wall mount NEMA 3R Aluminum or Stainless Steel construction. 42 Pad mount enclosures shall be provided with a channel APPROXIMATE WEIGHT 270lbs base, and wall mount enclosures shall have external 36 CABLE ACCESS CUTOUTS PROVIDED WITH IMPACT RESISTANT INSULATING BUSHINGS 26 BOTTOM ACCESS PANEL IS HELD CLOSED UNTIL FRONT LOCKABLE DOOR IS OPENED 4 INCH WIDE CHANNEL BASE PROVIDED FOR ELEVATED MOUNT ON CONCRETE PAD mounting ears. Generator connection cabinets shall be manufactured by Berthold Electric Company of Chicago, Illinois. Berthold Electric www.genconcab.com 800.657.6650

TO ORDER A BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET COMPLETE THE FOLLOWING CATALOG NUMBER Mounting Style Rated Continuous Current System Voltage Permanent BUS Connections Generator Connections Options W P Wall Mount Pad Mount 04 400 Amperes 08 800 Amperes 12 1200 Amperes 1 120/240V 1ph. 3W 2 120/240V 3ph. 4W 3 208/120V 3ph. 4W S C Mechanical Set Screw Lugs Long Barrel Compression Lugs S F Mechanical Set Screw Lugs Female E1016 Series Cam-Loks Leave blank for no options. See the table of options and the code number for each option required. 16 1600 Amperes 4 480V 3ph. 3W P NEMA Two Hole Punching Only M Male E1016 Series Cam-Loks 20 2000 Amperes 24 2400 Amperes 5 480/277V 3ph. 4W See cable termination table to verify the standard number and size of lugs 28 2800 Amperes Note: Berthold Electric can also provide generator cables and connectors. Contact us for more information. 32 3200 Amperes Cable Termination Table Table of Options and Option Code Numbers Permanent Feeder Connections Mechanical Lugs Available Options Option Code Current Range 400A-1200A 1600A-2000A 2000A-3200A Cable Range 4-2AWG to 600 MCM set screw lug positions 6-2AWG to 600 MCM set screw lug positions 8-2AWG to 600 MCM set screw lug positions Permanent Feeder Connections Compression Lugs Specify quantity and size of lugs or NEMA 2 hole punching. Generator Connections Mechanical Lugs See table above Cam-Loks Quantity provided based on 400A per connector. Access panel interlocking micro-switches 1 Key interlock provision provision only. Customer to supply and install Kirk Key Interlock Model #KDLO 1E or 2 Superior Interlock Model #B-5003-1 Phase Sequence and Failure Indication 3 Convenience Outlet Provision 5 Cam-Lok Snap Covers 6 Cam-Lok Black Rubber Caps 7 Welded Construction for Wall Mount Welded Construction for Pad Mount Powder Coat Gray Finish 9 Stainless Steel Construction 10 Select the options required and list the option codes in the suffix of the catalog number 8W 8P Example: The catalog number for a wall mount 1200A, 480V, 3-phase, 3 wire generator connection cabinet with permanent connections made by long barrel crimp lugs and generator connections made by male cam-loks with no options is W12-4C-M. Specify quantity and size of lugs. (Example: 2-500 MCM per Phase and Neutral, 1-3/0 Ground.) BERTHOLD ELECTRIC 1900 West Carroll Avenue Chicago, Illinois 60612 800.657.6650 312.243.5767 info@genconcab.com www.genconcab.com Major credit cards accepted. Berthold Electric also manufactures a wide variety of custom and madeto-order electrical power distribution equipment. Please visit our website for more information. www.bertholdelectric.com