IBM Portable Modular Data Center Overview for Critical Facilities Round Table



Similar documents
A Blueprint for a Smarter Data Center Data Center Services helps you respond to change

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime

IBM Twin Data Center Complex Ehningen Peter John IBM BS 2011 IBM Corporation

SMART SHELTER CONTAINER

Enterprise Data Centres

Data Center Solutions - The Containerized Evolution

The Pros and Cons of Modular Systems

Scalable. Affordable. Flexible. Fast.

Modular Data Centre. Flexible, scalable high performance modular data centre solutions. Data Centre Solutions...energy efficient by design

Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services

Huawei IDS1000 Container Data Center Solution

Automation's Modular Containerized Datacenter Solutions

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015

Types of Prefabricated Modular Data Centers

POD S in Data Centres. The Frame Group Pty Ltd

Simplifying Data Center Design/Build

THE WORLD S MOST EFFICIENT DATA CENTER

Data Centre Outsourcing a Buyer s Guide

High-density modular data center making cloud easier. Frank Zheng Huawei

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Introducing UNSW s R1 Data Centre

How To Design A Data Center

Enabling an agile Data Centre in a (Fr)agile market

LEVEL 3 DATA CENTER SERVICES IN SAN FRANCISCO HOUSE POWER-INTENSIVE APPLICATIONS AND SUPPORT BUSINESS CONTINUITY

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services

CANNON T4 MODULAR DATA CENTRE HALLS

Colt Colocation Services Colt Technology Services Group Limited. All rights reserved.

Sovereign. The made to measure data centre

Dealing with Thermal Issues in Data Center Universal Aisle Containment

AIRAH Presentation April 30 th 2014

in other campus buildings and at remote campus locations. This outage would include Internet access at the main campus.

Energy Efficiency and Availability Management in Consolidated Data Centers

Case Study Nottingham Trent University

Subject: County of Los Angeles Data Center Space Requirement

Elements of Energy Efficiency in Data Centre Cooling Architecture

Essential NCPI Management Requirements for Next Generation Data Centers

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

opdc Cut your data center OPEX upto 70%

La modularidad a nivel de Data Centers integrales. Arturo Maqueo Business Development Manager Mexico y Centro America

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Increasing Energ y Efficiency In Data Centers

Managing Cooling Capacity & Redundancy In Data Centers Today

European Business Reliance Centres when Commodity serves Green IT

Technical specifications. Containerized data centre NTR CDC 40f+

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

TIA-942 Data Centre Standards Overview WHITE PAPER

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

NORTHERN VIRGINIA ONE (NoVa) DATA CENTER OVERVIEW

The Data Center is the Lifeblood of Medical and Healthcare Facilities. We Design and Build Data Centers.

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Data Center Trend: Distributed Power in the White Space

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

Green Data Centre Design

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

CYRUSONE COMPANY OVERVIEW BUILT FOR TOMORROW. READY TODAY.

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

Leveraging Radware s ADC-VX to Reduce Data Center TCO An ROI Paper on Radware s Industry-First ADC Hypervisor

Consulting Engineering Outsourcing

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

In Row Cooling Options for High Density IT Applications

Advania Cloud Co-location

Modular / Prefab Construction: Speed, Reliability, Quality. March 2015 Jack Pouchet, VP Business Development and Energy Initiatives

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

DATA CENTER SOLUTIONS GUIDE

Greening Commercial Data Centres

The Data Centers of the Future Are Here Elliptical Mobile Solutions The Global Leaders in Micro-Modular Data Centers TThElliptical Mobile Solutions

Huawei Data Center Facility Integration Solution

Top 5 Trends in Data Center Energy Efficiency

SYMANTEC NETBACKUP APPLIANCE FAMILY OVERVIEW BROCHURE. When you can do it simply, you can do it all.

What is a Datacenter?

BRUNS-PAK Presents MARK S. EVANKO, Principal

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

Blade Server & Data Room Cooling Specialists

Data Center.

Global Green Data Center Best Practices In Action

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group

Transcription:

Brian Canney Global Services Executive, IBM GTS Site and Facilities Services April 2011 IBM Portable Modular Data Center Overview for Critical Facilities Round Table 2009 IBM Corporation

Key messages Containers are not the only modular solution, but the containerized data center market has been growing for many years and continues to catch on Containerized data centers must be flexible, modular, quick to deploy data center solutions for use in any environment, anywhere in the world Identifying the intended use is the critical step in translating clients needs to the data center design requirements. Operational considerations remain the key evaluation criteria for a data center: Availability for continuous operations Flexibility of design and location support Quick to deploy data center solution Leverage a partner with vast data center design and build experience to help determine and implement your data center needs 2 April 15, 2011

Design new data centers for flexibility IBM s data center family TM solutions align to your business and cost objectives. Scalable modular data center Enterprise modular data center Portable modular data center High density zone 15-20% lower TCO than traditional data centers Defer 40-50% of capex and opex cost Fully functional data center 35% lower cost than site retrofit Functional mid-size data center Improve availability & scalability Deploy in 8-12 weeks Flexible capabilities over 20 years 18x power and cooling growth Modules sizes starting at 5K sq ft. Implement any where, any climate Continuous operations during IT maintenance Deploy in 12-14 weeks. Watch a video at :http://www-03.ibm.com/systems/data/flash/dynamicinfrastructure/datacenterdesignsolutions/ 3 April 15, 2011 New life to older data centers Minimal operations impact during upgrade

IBM PMDC includes the requirements for a new data center Focused on providing continuous operations and flexibility Business objectives Meet business and IT growth Align capital and operating costs Flexible to support new technology Faster time to deploy Reduce risk Security Data centre requirements High availability Provide required capacity Optimize capital costs Maximize scalability Maximize flexibility for technology and computing model adoption Minimize capital and operational costs Interconnect IT, data centers and buildings for data centre operations management excellence 4 April 15, 2011

Perspective on containerized data center market Based on discussions with over 1000 companies, we ve seen the containerized data center market experience its own hype curve in the past few years. Curious Info Gathering Serious Clients showed interest but did not understand the solution, how to apply it or how it would fit in their IT structure. Same clients return with more educated inquiries to determine right fit for the right use. 1 2 3 4 Time (years) 5 April 15, 2011 More insightful proposals requested based on intended use and data center requirements.

IBM has global experience in modular data center design and build and containers Over 500 implementations of modular data centers in the past 2-3 years Scalable modular data center Enterprise modular data center Portable modular data center High density zone Custom data centers 6 April 15, 2011

A Snapshot of Some Successful IBM PMDC Engagements INDUSTRY COUNTRY PMDC Configuration Energy Denmark 1 x 20' Distribution (Heavy Equipment) Australia 2 x 20' IT Spain 1 x 40' + 1 x 20' Finance (Banking) Poland 1 x 20' Oil and Gas Turkey 1 x 20' Telecommunications Canada 2 x 20' Military USA 4 x 20' + 1 x 10' Military USA 4 x 20' + 1 x 10' Finance (Banking) Denmark 2 x 10' + 2 x 20' + 3 x 40' Finance (Banking) Denmark 5 x 10' + 9 x 40' Hosting USA 1 x 40' Media Australia 1 x 20' + 1 x 40' Pharmaceutical Italy 1 x 20' Telecommunications Russia 3 x 40' Military Norway 2 x 40' Power Management Malaysia 2 x 20' Finance (Banking) Pakistan 1 x 40' Finance (banking) Russia 5 x 20' Transportation / Distribution Belgium 1 x 20' Retail Netherlands 2 x 20' Chemical China 1 x 20' 7 April 15, 2011

The intended use is the critical step in translating clients needs to the data center design requirements. Remote data center Remote locations Where building a data center is challenging Emerging markets - critical skills may not be available Space challenges Alternative to co-location Take advantage of low energy cost areas Remote users: Oil/gas exploration, mining, offices, manufacturing Portable modular data center Temporary data center Mobile data center Data Center Expansion Temporary data center solutions Address increased needs during construction Mobile Applications Military needs Sporting events Data Center Expansion Address space concerns High density cooling solutions Disaster recovery Business cycle coverage Movie production Disaster avoidance / recovery Co-location alternative Low cost real estate Consolidation / Rationalization Cloud computing Cloud Computing High performance computing applications Point of use locations Locate in low cost areas (lower TCO) Specialized needs 8 April 15, 2011

IBM s PMDC provides the operational features you expect in a fully functioning data center in the form factor of our container solution Continuous IT operations to meet availability needs Allow internal service and maintenance without operations disruption Provide physically secure environment with complete IT and data center infrastructures Improve internal service and maintenance with a low density rack rail system by removing potential aisle-way obstructions Flexible designs to meet specific client needs Complete data center infrastructure designed and sized to meet your specific needs IT environment designed to support open IT architecture with most any type IT rack Improve energy efficiency while reducing risk of contamination with a 1.5 year payback with natural free cooling Increase rack capacity by 15-20% with the motorized IT rack rail system Quickly deploy a fully functional data center anywhere in the world Complete, flexible solutions with full data center infrastructure Solutions provide complete installation flexibility in any environment anywhere in the world Typical deployment in 12 14 weeks 9 April 15, 2011

Pelio and Associates chooses IBM PMDC containers for modular data center park to house clients at co-location facility Business challenge: Client needs on demand data center capacity to meet needs of their co-location clients Ability to meet configuration and security needs of many clients Typical co-location space does not fit new business model Ability to defer capital and operating costs until business drives data center space needs Solution: Flexible and scaleable designs to meet multiple client needs with varying levels of redundancy: N, N+1, 2N at the same site Open IT architecture to support any client IT equipment Quick to deploy solution which can be integrated into existing support infrastructure A ready-to-run data center solution for quick response to new clients Benefits: Most capital- and energy-efficient solution customized to a specific user's requirements Defer capital and operating costs of data center space until needed Quick response to new client needs with ability to plug into existing power, cooling and connectivity at installation site Provide the data center capacity each client needs with individually secure areas Total solution fully tested prior to shipment 10 April 15, 2011

PMDC provides continuous IT operations to meet data center availability requirements Allow internal service and maintenance without operations disruption IT rack rail system allows front and rear access to IT equipment Easy access to all power and network distribution cabling Environmental isolation maintained during IT operation, service, maintenance and moves/adds/changes Provide complete IT and data center infrastructure Self-sufficient data center with complete infrastructure Complete redundancy options for all sub-systems, allowing concurrent maintenance Energy efficient designs with a PUE of 1.3 or better Complete infrastructure and environmental monitoring Physically secure data center environment Data center access control, multi levels available Closed circuit television monitoring Completely secure environment during operations, service and maintenance Front of Rack Service Rear of Rack Service 11 April 15, 2011

IBM PMDC provides design flexibility to meet your specific IT and data center needs today and is scalable to meet future needs Complete data center infrastructure Designed to meet IT capacity requirements Infrastructure can include complete, self-sufficient solution or any sub-set required Incorporate industry leading infrastructure equipment from IBM s global partners IT environment designed to support open IT architecture Support any manufacturer s IT racks Leverage copper and/or fiber cabling for network systems Support non rack-mounted equipment as needed Solutions provide complete installation flexibility in any environment Unique environmental isolation systems allows safe, continuous operation in any environment with no need for protective coverings or buildings Multiple cooling systems including DX, chilled water and natural free cooling Seismic isolation systems at either container or rack level allow worry-free installation in earthquake prone areas 12 April 15, 2011

Multiple PMDC configurations = flexible designs Single Container Solution All-in-one design IT equipment and infrastructure in a single container Use when space for containers or IT equipment needs are limited Lower cost, compact solution Multi-Container Solution IT Equipment Container (Server Container) IT equipment, cooling, power distribution, fire suppression, remote monitoring, physical security in one container Use for maximized IT equipment installations Supported by physical infrastructure container or existing building services Physical Infrastructure Container (Services Container) UPS/batteries, power switchboard, chiller, fire detection/suppression, cooling, monitoring Designed to support IT equipment container or traditional data center environment 2(N+1), 2N, N+1 or N design 13 April 15, 2011

IBM PMDC can provide a complete, reliable and redundant data center solution quickly Complete, flexible solutions with full data center infrastructure delivered quickly Designed and built within 12 14 weeks instead of 18 24 months Complete data center infrastructure including chillers, condensers, UPS systems, fire and monitoring systems, etc. Tightly controlled construction Built in 1 of 3 controlled manufacturing facilities Repeatable, tightly monitored process using fully trained, experienced personnel No weather or resource delays and no local construction inspection delays Full system testing prior to shipment Every PMDC is fully tested prior to shipment to client location Witness testing is available if required Shipped units are fully functional and ready to operate 14 April 15, 2011

Providing a flexible, cost-effective data center Down Under to meet immediate business needs Business challenge: Needed additional data center capacity fuelled by unexpected increase in demand Unable to secure more data center space Co-location space did not meet needs Tight deadlines to implement Solution: Open IT architecture to support client IT equipment Designed, built, tested and delivered as a complete solution Provided IT and infrastructure containers Complete infrastructure solution: UPS, batteries, chiller, RDHx cooling units, security, power distribution, fire systems, engine generator, switchgear, fuel tanks, etc. Benefits: Addressed IT needs much faster (~8 weeks) than possible through other methods Allows for future disaster recovery operations Total solution fully tested prior to shipment 15 April 15, 2011

Utilizing a broad ecosystem of partners to combine the engineering and technical expertise of IBM and our partners to provide implementation choices Construction and design of modular data centers. Electrical components and systems for power quality. Data center power, cooling and monitoring solutions. High density cooling solutions. Network cabling solutions. Plug-in Raceway Power and automation technologies Fire detection and Suppression systems Secure Power Products for wiring and communications applications. Data and telecommunications racks Precision air-conditioning systems and chillers 16 April 15, 2011

IBM provides a complete solution and can help clients implement a solution any where and in any climate DETERMINE REQUIREMENTS What are your data center requirements? Strategy Intended use Growth requirements Installation location Integration with existing systems DETAILED PLANNING / DESIGN Create a design based on the requirements. Flexibility to support multiple technologies Scalable to meet current and future needs Complete infrastructure systems Incorporate into existing or new facilities TURNKEY SOLUTION Turnkey solution: Installation site design Permit processes Site preparation and installation Security system design and installation Connections to existing or new utilities Incorporate into campus aesthetics 17 April 15, 2011 START UP TESTING/ SITE TURNOVER Site turnover: IT equipment relocation and migration Start up / test complete solution Client operation training Ongoing maintenance and service coordination

IBM PMDC Installation Brondby, Denmark (NFC Cooling) Two diesel generators Service container for Cooling and Power NFC NFC Twin IT container 18 April 15, 2011

PMDC Brøndby specifications 100 kw IT load capacity at 80% redundant supply capacity Twin IT container with 14 racks and 8 positions for storage frames etc. Dual bus to dual cord IT hardware N+N electrical design and N+1 cooling design IBM standards for security and access control 24x7 operation and monitoring integrated with existing site systems and staff Highest PUE (Power Utilisation Efficiency) of any of the IBM Nordic data centers Interface to power, water and cabling for IT data, monitoring and access control 19 April 15, 2011

PMDC Brøndby design Two UPS s one can carry the 100 kw IT load at 80% Dual bus fed by dual UPS dual cord IT hardware connects across Two diesel generators one can carry the 100 kw IT load and cooling load at 80% Three cooling systems for efficiency NFC (Natural Free Cooling) running N+1 the primary system Evaporation used for energy efficiency at higher temperatures Chillers, dry coolers and thermal storage running N+1 used at high temperatures Monitoring alarms for support systems and fire integrated into existing facility systems Two fiber cabling paths integrated into existing data center patch panels Monitoring and operation services by the same team for existing data center and PMDC Management, documentation and installation services by the same team for existing data center and PMDC End-to-end availability managemnet of the physical infrastructure (IT and facility) 20 April 15, 2011

PMDC benefits Much faster from order to up and running over traditional data center builds End-to-end availability management of the physical infrastructure (IT and facility) Very efficient cooling technology compared to existing data centers saves power and CO2 For one watt IT equipment the system only uses 0,13 watts to cool More efficient use of space for IT hardware with 2000W/m 2 Can be moved to where needed Quality system 21 April 15, 2011

IBM PMDC Installation Ejby, Denmark 22 April 15, 2011

US Military Application 23 April 15, 2011

IBM PMDC Perth, Australia 24 April 15, 2011

IBM PMDC Perth, Australia 25 April 15, 2011

IBM PMDC Madrid, Spain 26 April 15, 2011

IBM Portable Modular Data Center IBM PMDC Sydney, Australia 27 April 15, 2011

NFC Traditional Data Center Configuration 28 April 15, 2011

NFC Application in Reykjavik, Iceland Cold Air Supply Side 29 April 15, 2011

NFC Application in Reykjavik, Iceland Hot Air Exhaust Side 30 April 15, 2011

NFC Application in Reykjavik, Iceland Cold Aisle of IT Container 31 April 15, 2011

Leverage IBM s experience to help For CIOs: www.ibm.com/cio For facilities managers: www.ibm.com/services/siteandfacilities For PMDC: www-935.ibm.com/services/us/index.wss/offering/its/a1030715 32 April 15, 2011