Silo Temperature probe. Silo thermometry. www.loreme.fr E 1 SILOTHERMOMETRY REV2B - 14/10/13



Similar documents
Capteur température et humidité pour HVAC

IMVIB. Online vibration monitoring for Ariel compressors

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Combi switchbox with integrated 3/2 way pilot valve

S1VF Sonde à visser avec tête de raccordement Threaded probe with terminal head

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

WEB log. Device connection plans

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

NEW. EVEN MORE data acquisition and test stand automation

Inductive sensor NI10-M18-Y1X-H1141

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Digital inductive conductivity transmitter

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Mureva Assembly surface mounted wiring devices

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Series 7500 Torque Sensor

Measuring Temperature withthermistors a Tutorial David Potter

PART 1 - INTRODUCTION...

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

ATL Fuel Level Sender Probes

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Inwall 4 Input / 4 Output Module

Application/Connection Examples

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Optimize your simple machines... Modicon M218 Selection Guide

Cable Plug acc. to DIN EN , Form A

Plastic tube flowmeters Series PT/PS

Process Alarm Solutions

API Marine. BMS Presentation. Ballast Measurement Systems

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

ACS-30-EU-EMDR-10-MOD

PROXIMITY CARD READERS C-10, C-20, C60, C70

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

EDI Distributor Control Interface Wiring and Setup Instructions

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Test equipment for temperature and its reduction

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Barcode Reader Series BCL 31, BCL 32, BCL 34

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Series 6000 Torque measured metal bellow coupling

How To Use A Flowmeter

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

WIRELESS INSTRUMENTATION TECHNOLOGY

Electronic Control Devices The European Product Catalogue 2007

USB-500 Series Stand-Alone, Low-Cost Data Loggers

WEB log. Device connection plans

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

K-Type Thermocouple Sensor User s Guide

LOCAL INTERCONNECT NETWORK (LIN)

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

HARTING Ethernet Cabling 8-poles Overview

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

USER MANUAL V5.0 ST100

New XUY roller sensors

Rosemount 333 HART Tri-Loop

TX2123 RS485 TO ETHERNET ADAPTOR

SDI Multi Sensor Module with Charger Enclosure Station Support

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

How To Use A Ds340 (Dsp)

Digital input modules

is then retained absolutely without interruption.

MLC TM Maximum Productivity and Versatility for Control without Compromise!

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Regards from the Team at Rheology Solutions.

Material test chamber with mechanical convection

SmartLogger1000. Quick Installation Guide. Issue 05. Date HUAWEI TECHNOLOGIES CO., LTD.

Shunt lock function 3066

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Control- and feedback head for integrated mounting on Robolux valves Type 2036

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Digital display DA 48

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

L5354 ControlNet Communications Interface

Perimeter Security System

Transcription:

Silo Temperature probe Silo thermometry C www.loreme.fr SILOTHERMOMETRY E 1 REV2B - 14/10/13

FLEXIBLE PROBE FOR SILO TEMPERATURE MEASURE Type: SILOFLEX Easy and fast mounting To suspend or flanged Analog or numerical technology Standard sensitive elements RTD, NTC, PTC, or numeric addressable sensitive element allowing connection of 24 sensors by 3 wires!! Temperature from 55 C to +125 C Polyethylene external sheath Very high traction strength, armed with steel wires, very low lengthening, very low adherence (pull limitation), low diameter : 14mm limiting tensile stress, waterproof IP65, food-compatible materials Area 0 or Area 20 ATEX notification Dust explosible area Notification: 01atex 6052x Flexible silo probes type "SILO FLEX" are available in all lengths with up to 24 temperature points. They are declined in two versions, one with analog sensitive elements (type: RTD, NTC or PTC), the other with numerical adressable sensitive element. Flanged version with ATEX head 1) Analog version (SILOFLEX -A) Two wiring are possible: Independent sensor (2 or 3 wires mounting) With possible line length compensation Recommanded for RTD sensitive element. 3 wires mounting: 8 elements maximum. 2 wires mounting: 12 elements maximum. Sensor with common point (only in 2 wires mounting) Without wire length compensation Recommanded for RTD, NTC, PTC 23 elements maximum are possible by sensor 2) Numerical version (SILOFLEX -N) With this technology, sensitive elements are adressable silicium sensors with single serial number. All the elements are connected in parrallel on a 3 wires bus simplifying the wiring and reducing implementation cost. Data processing: LOREME recommend the aquisition stations type INL 100 and INL 100N (for numerical sensors), for exploitation of his silo probes, allowing: watching, visualization, alarm control and communication to automaton or PC (modbus or profibus protocol). M 2 LOREME 12, rue des Potiers d'etain - 57071 Metz 03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Technique@Loreme.fr REV2A - 06/02/09

Sensor end with a hooking system. Hook version FLEXIBLE PROBE FOR SILO TEMPERATURE MEASURE Silo sensor definition Parameters to define by the user are : - Overall length sensor - Fastening mode: flange (DN, PN, face type), hooking,... - Distribution of the measure points (equidistant distribution by default), - Material inside silo - Silo dimensions Sheath characteristics polyamide V11 matter, 14mm external diameter 2000 kg traction resistance, 4000Kg rupture resistance IP65 protection, maximum temperature holding 125 C Load diagrams are given for grain with 750 kg/m3 average specific weight (wheat, maize, soya) for barley and colza, reduce 10% (700Kg/M3), and for sunflower, reduce 30% (450Kg/M3). Load diagrams are given with a 20% safety margin and allows including product hygrometry variations. Sensors response time SILOTHERMOMETRY M 3

Bottom Top FLEXIBLE PROBE FOR SILO TEMPERATURE MEASURE Analog sensors wiring (SILOFLEX-A) Common point wiring Standard wiring Colors acc. DIN 47100 Colors acc. DEF STAN 61.12 pt1 & pt4 Colors acc. BS4737 White Red Red 1 2 3 4 5 1 2 Maroon Blue Blue Green Green Yellow Yellow Yellow Black Gris White White 6 Pink Black Green 7 3 Blue Maroon Orange 8 Red Violet Maroon 9 Black Orange 10 4 Violet Pink 11 12 13 14 15 5 Gris Pink Turquoise Red Blue Gris White Green Red Blue Maroon Green Green Red White Yellow Yellow Red 16 6 Yellow Maroon White Red 17 White Gris Red Black 18 Gris Maroon Red Maroon 19 7 White Pink Yellow Blue 20 21 22 23 8 Pink Maroon White Blue White Blue Blue Black Maroon Blue Orange Blue White Red Green Blue Maroon Red Gris Blue Digital sensors wiring (SILOFLEX-N) + - Blanc White Data Rouge Red Noir Black +5V Gnd Incolore No Color Terre / Earth Terminal DATA E 4 LOREME 12, rue des Potiers d'etain - 57071 Metz 03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Technique@Loreme.fr

Operating principle of a solution based on numeric temperature sensors in Silo application. The numeric silo probe use a communication bus called 1 wire. The data are transmit in 1 wire and in bidirectional way. The two other wire of probe are used for power supply. Each temperature sensor have an unique 64bit identifier number and a 8bit position register (this register is define at the probe making. This register is use to define the sensor position inside the silo probe). The communication working in master / slave mode. Each silo probe are interrogated one after another through a multiplexer, the time to complete reading of a probe is approximately 25ms per temperature point. The silo probe are «plug and play» type and there are interchangeable in service, No installation procedure is needed. Operation: For each new silo probe reading, a specific search algorithm define the number of temperature sensors present in silo probe and verify the consistency with the configuration set in device. (detection possible point out of order during operation). Once all points are identified, the device reads the temperature value and the position of each sensor and treat them to alarms, display, external communication, and go to the next silo probe. Security: All data exchange are controlled with a checksum. A transmission error give automatically an reiteration. Each probe is fully re-initialised before each reading. This operating mode allows a perfect fiability of measure and avoids false alarms. Internal constitution of a numerical Silo temperature probe Synoptic of implementation and internal structure of a INL100N Numeric Silo probe Link cable (3 wires shielded) 200 meters max length SILOTHERMOMETRY E 5

Définition capteur Silo / Silo temperature sensor specification Not available with SILOFORM (Stainless steel) version Non disponible avec la version SILOFORM (Inox) 200 mm min. Total Length = Not available with SILOFORM (Stainless steel) version Non disponible avec la version SILOFORM (Inox) FLEXIBLE PROBE FOR SILO TEMPERATURE MEASURE 90 days accuracy (20 C +/- 2 C) DATA SHEET CAN BE DOWNLOADED ON WWW.LOREME.FR TECHNICAL SPECIFICATIONS Accrochage en charpente / Hook fastening (Option) Accrochage en charpente / Hook fastening (Option) Tête de raccordement / Connection head Sans protection / No protection Sécurité intrinsèque / Intrinsically safe (Zone :... ) Anti-deflagrante / Explosion-proof (Zone :... ) Fixation / Fastening system Manchette soudée sur bride / Nipple welded on flange DN... PN... Face :... (or... "... # Lbs Face :... ) Raccord / Connection Type :... Accrochage forte charge (Option) / High load fastening (Option) Elément de mesure / Measuring element RTD PT100 (Montage 3 fils / 3 Wires mounting) RTD PT1000 (Montage 2 fils / 2 Wires mounting) RTD PT1000 (Montage 2 fils avec point commun / 2 Wires mounting with common wire) Numérique / Digital Autre, précisez : Other, specify : Gaine / Sheath Polyamide Ø 14 mm Inox 316TI / 316TI Ss. Ø 8 mm Accrochage standard / Standard fastening Point n 01 Point n 02 Point n 03 Point n 04 Point n 05 Point n 06 Point n 07 Point n 08 Point n 09 Point n 10 Point n 11 Point n 12 Point n 13 Point n 14 Point n 15 Point n 16 Point n 17 Point n 18 Point n 19 Point n 20 Point n 21 Point n 22 Point n 23 Point n 24 Position point (L sous fixation) => 500 mm min. pour le point n 1 => 250 mm min entre 2 points Point position (up to fastening system) => 500 mm min. for n 1 point => 250 mm min between 2 points Accrochage forte charge / High charge fastening (Option) Accrochage standard / Standard fastening E 6 LOREME 12, rue des Potiers d'etain - 57071 Metz 03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Technique@Loreme.fr On account of the constant technologies and standards evolution, LOREME keeps the possibility to modify the specifications of the included products without notice.

FLEXIBLE PROBE FOR SILO TEMPERATURE MEASURE Temperature acquisition and monitoring station. TYPE : CML100 Up to 16 mesures channels for each module Temperature : RTD input (PT100, PT 1000) Thermistor input CTN, CTP Thermocouple input (B,E,J,K,R,S,T, ) Process : 0..1.5...10Volts ; 0...4..20mA Strain gages Modbus TCP Ethernet link DIN rail Internal direct bus connecting ability Option : Power over Ethernet (POE) Application : Acquisition interface for controller or automaton Process monitoring CML100 is a monitoring station for analog signals. It permit acquisition of temperature sensors or process signals and data providing on Ethernet link (Modbus TCP protocol). The internal Bus permit to connect multiple moduls on a single Ethernet link. CML100 modul is a «BUS100» system part and can be mixed with the other moduls of system. (Digital input modul : ELL100 and Relay output modul : SRL100,..) Temperature acquisition and monitoring station. TYPE : CML36 Up to 14 mesures channels for each modul Temperature : RTD input (PT 1000) Thermistor input CTN, CTP Power and communication bus DIN rail incorporated 64 module interconnection available 1 Modbus TCP Ethernet link For the entire bus => up to 896 mesures points Application : Acquisition interface for controller or automaton Process monitoring Silothermometry CML36 is compact temperature monitoring station. It permit to connect up to 64 moduls (14 channels for each device) on a single Ethernet link (Modbus TCP protocol) by an internal bus. SILOTHERMOMETRY E 7

FLEXIBLE PROBE FOR SILO TEMPERATURE MEASURE Measurement, acquisition and monitoring central Type : INL100 and INL150 Process and temperature inputs (mv,ma,thermocouple,pt100) INL100 : 4, 8 or 12 inputs. INL150 : 16, 20 or 24 inputs. - single configuration for each input. - 2 alarm threshold by input. - analog output (option). Communication : - Profibus-DP - Modbus - Modbus TCP Application : - acquisition interface for PLC. - process monitoring. IP65 Box option 200x200x170 Due to its modularity this product can assume simple functions like signal scanner with alarm management or advanced functions up to communicating measurement central with advanced processing function. Silo temperature monitoring station INL100N and INL150N type Up to 576 temperature points on a single device (INL150N 576 points - INL100N 288 points) 3 wires cable by Silo sensor Digital sensors in 3 wires network (-55 C to +125 C) Polling time 25 ms / measure ( 576 measures in 15 seconds) IP65 Box option 200x200x170 Accuracy: +/- 0.5 C Output relay (prewarning alarm, alarm and Watch dog) Communication option - Modbus - Modbus TCP (on Ethernet) - Profibus INL150N is monitoring station allow assorting a large number of temperature sensors in a single device. The technology «all digital» of this set, reduce significantly the wiring and implementation costs, because of sensors inter connecting on 3 wires bus. E 8 LOREME 12, rue des Potiers d'etain - 57071 Metz 03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Technique@Loreme.fr