Customer: Cardiff Hospital NHS (United Kingdom) Machine:



Similar documents
italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

FVA/A1 saturated-steam sterilizer

FF30. Flexicon. Operator s Manual. FF30-F In-feed Rotary Table. OPERATOR S MANUAL Serial Number yyww xxxx. Filling and Capping System

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection

Water Leak Detection System

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150

AUTOCLAVE STEAM STERILIZERS

FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Shunt lock function 3066

...een product van BEKA

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Metal-Oxide Varistors (MOVs) Surface Mount Multilayer Varistors (MLVs) > MLN Series. MLN SurgeArray TM Suppressor. Description

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Wolflite Safety Handlamp H-251E

Ref. Nr LCP-288 LED COLOR PANEL 288X LED 5MM MANUAL

Senses SV series industrial monitor user manual

EC DECLARATION OF CONFORMITY FOR MACHINES

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

LAMINAR FLOW CABINETS

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

OT 40L / 90L. Laboratory Steam Sterilizers

Secondary Unit Substations

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

OPL BASIC. Dosing System for Professional Laundry machines. Contents

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

EcoCWave. The all-round talent for aqueous part cleaning.

OPERATING INSTRUCTIONS

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Central Purchase unit National Institute of Technology Srinagar Soil Mechanics Lab of Civil Engineering Department.

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

High Security Heavy Duty Shredders VZ Perfect shredding and high performance in DIN security levels 4 and 5

Milwaukee USER MANUAL

SEISMIC VELOCITY TRANSDUCER T1-40

Product and functional description

Manual for Fire Suppression & Methane Detection System

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

TECHNOLOGIES FOR SLEEVE APPLICATIONS. English catalogue

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Periodic Verification System Model 775PVS

Power consumption (kw)

HSL-VS Vials + Syringes

Technical Information

Spetec. Laminar Flow Box. Portable Clean Room Technology

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Multifunction devices

EUROTUBO DELTALAB 4. PETRI DISHES AND LOOPS

PHARMACEUTICAL GLASS CONTAINERS AND PARENTAL DRUGS INSPECTION

Conductive Level Switch FK 2 Technical Data:

T 300 Tray sealer. Automatic tray packaging in the smallest of spaces

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

Morgue refrigeration unit

DMX2PWM 9 Channel Dimmer Setup Manual

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

LABOKLAV. Autoclaves Made in Germany.

Mureva Assembly surface mounted wiring devices

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

PHA 2000 PHB 3000 EXIT PAD

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

EMERGENCY EGRESS LIGHTING POWER SUPPLY PART NO COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Specific volume and absorption properties

DUOTOUR WITH SLIDING DOORS OPERATING MANUAL

Spetec Laminar Flow Systems. Operating Instructions

V1504 Vertical Platform Lift OWNER S MANUAL

THE FIRST OF A NEW CLASS OF PRODUCTS

Flow switches Series AD/VH

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

intelligent solutions

Energy Management Energy Meter Type EM23 DIN

LockerLock Schließgehäuse LockerLock lock case Boîtier de fermeture LockerLock Scatola di ciusura LockerLock Caja de cierre LockerLock

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

WE-350 Series ¼ Turn Electric Actuator

TIG torches to 3-5 Tungsten electrodes to 3-7 TIG consumables Miscellaneous

READING DEVICE US-05

Saferand easierinstallation

STEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified:

Cable Tester Pro ORDERCODE D1909

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

V1504 Vertical Platform Lift OWNER S MANUAL

Tube Liquid Sensor OPB350 / OCB350 Series

TENSIONMETER ** code 183_LNRSTW **

Transcription:

Customer: Cardiff Hospital NHS (United Kingdom) Machine: Bench for leak test Model: Easy TS Page 1 of 7 Date: 6 th March 2012

1. Introduction. Easy TS is a compact and reliable table top bench designed to perform the leak test in glass ampoules for pharmaceutical use This system is capable to detect microholes of the dimension of some micron that can compromise the sterility of the product. It can be installed in laboratory for non destructive quality test or it can be present in production lines for sampling test. The execution of the test is very fast (the electronic measurement takes about 0,1 sec) and the use is absolutely simple and safe for the operator. 2. Principles The test is based on the analysis of the current flowing in measurement circuit (Fig. 1) after the application of an high voltage between the two electrodes HV and LV. If the container is correctly sealed, the current flowing is very low because the glass of the container is a perfect isolator. In case of presence of a microfissure an electric spark is generated through the conductive liquid with a capacitive current very high and easily recognizable. Control board HV LV Figure 1 Test circuit Necessary condition for the correct verification of the test is that internal surface of container in the tip and in the area around LV is wet by internal liquid. Test time is very short (around 50 ms) and there s no mechanical stress to the container nor transfer of energy (less than 0,1 J) without any risk of contamination of the product. Not only one spark is generated but trains of pulses at adjustable power are generated at a fixed frequency for each container. Each single pulse has the effect to generate a current; the control board is used both to control the generation of pulses and to process the signal acquired. Page 2 of 7

A special algorithm is applied enabling to send to PLC two analog values proportional to the peak current and to the average current; each one of the two value is compared with its own minimum threshold. If at least one of these two thresholds is exceeded, the container is considered rejected. 2. Features Test is automatically performed by pressing the green pushbutton in the front panel: two lamps signal to the operator the result of the test; green lamp means GOOD, red lamp means REJECT. Figure 2 Panel detail with pushbuttons, lamps and display Only four parameters are needed for the setup: the power and duration of the sparks and the two thresholds (for average and peak current) for sensitivity adjustment. The value of the results are visualized on the display both in numerical and graphic way. These parameters can be memorized in receipts (up to four). Display visualizes also the number of sparks emitted and the number of positive and negative test with percentages. Operation is fast and very easy: operator simply puts the container in appropriate horizontal position between the electrodes and presses the pushbutton: no specific skills are required. Page 3 of 7

3. Construction The base is made in stainless steel AISI 304/316L, while the external upper frame is in anodized aluminium. Plastic parts, that can be in contact with the leaked product, are in FDA approved plastic material (PE or POM C). Covers are in transparent lexan. The device is equipped with Siemens PLC and Interface panel The front door is protected by two key microswitches connected to a safety control unit. For safety purpose, the spark is not emitted when door is open. 4. Size change Size change is performed, without any tools, changing the position of the electrode close to the tip, according to the height of the ampoule. Required time: 1 minute only. Page 4 of 7

5. Technical Specifications Dimensions (LxWxH): Weight Electrical supply Power Supply Containers Diameter of container Volume Products Conductivity of the product Lasting of test High Voltage applied to the container Minimum detectable hole Area of inspection Conformity 400x350x650 mm. approx 15 kg. approx 230V 50Hz 1Ph 250W 1A Glass ampoules 9 25 mm 1 30 ml Liquids 3 µs/cm 30ms 200ms Up to 35 KV 5-10 micron Tip and bottom of the ampoule Machine is compliant to CE rules Page 5 of 7

6. Prices DESCRIPTION PRICE Nr. 1 Bench for offline leak test Easy TS including: Siemens panel interface for parameters setup and visualization of results. Siemens PLC Start test pushbutton and lamps for immediate visualization of the result One size able to test ampoules up to 30 ml with adjusting sliding electrode Emergency pushbutton Two emergency microswitches on front door Electrodes setup for inspection of tip and bottom User and maintenance manual Packing 22.300 7. Training Although the device is very simple to be used, a short training with test performed together with a Convel technician is very useful and recommended. The training can be performed in Convel, free of charge, lasting one full day. 8. Payment 30% down payment at order by T/T transfer 70% at delivery by T/T transfer Payment is in euro 9. Delivery time 60 days from the order, definition of all technical details and reception of samples. Delay in reception of samples can affect the delivery time 10. Delivery terms Ex works Dueville (Incoterms 2000) Page 6 of 7

11. Warranty The bench is guaranteed 12 months from installation date against malfunctioning coming from defective mechanical or electric parts that will be replaced free of charge. Malfunctioning due to customer misuse will be on customer charge. 12. Validity 90 days from the date of the offer 13. Conditions The customer shall guarantee a fluctuation of machine power supply within 10%. All external surfaces of the containers must be dry and clean. Customer understands that efficiency of the test is conditioned by conductivity of liquids. Convel takes the right to verify that the conductivity of the liquid is inside the requested range. Convel takes the right to verify that geometry of the cap enables the test conditions Customer must provide about 50 samples for each product and size at the order. 14. Layout (dimensions are in mm) Page 7 of 7