1 ОКП SCIENTIFIC AND PRODUCTION COMPANY «DOZA» READING DEVICE US-05 Operation manual

2 Table of contents 1 Reader description and operartion Purpose of the device Technical specifications Reader components Reader design and operation Marking and sealing Packing Intended use Operational limits Preparing reader for operation Product use Technical maintenance Overall notes Safety precautions Technical maintenance order Routine repairs Storage Transportation 6 7 Utilization

3 The present operation manual contains information of the design, operational principle, technical specifications and instructions necessary for correct and safe application of the device (intended usage, maintenance service, routine repairs, storage and transportation), and also information of decommissioning the device. 1 READER DESCRIPTION AND OPERATION 1.1 Purpose of the device Reading device US-05 ФВКМ (thereafter US-05) is intended for providing bidirectional data exchange between PC and DKG-05D type dosimeters (thereafter dosimeter). US-05 provides archive reading, dosimeter parameters setting, and changing time interval of periodic writing of data from remote PC receiving logs to the archive. 1.2 Technical specifications Physical line for data exchange between US-05 and dosimeter..... infrared emission The interface between US-05 and PC is a COM-port US-05 feeding must be from single-phase alternating current V, 50 Hz Feeding power..... no more than 0,5 W The type of climatic design is NF4.2* as per GOST Environmental parameters for US-05 in a working state according: - working temperatures range.... from 0 to +40 С; - relative humidity limit value % at +35 С; - atmospheric pressure ranged from 84,0 to 106,7 kpа; - corrosive agents air concentration - corresponds to the type of atmosphere I, III US-05 is resistant to sine vibrations in frequency ranges: - from 2 to 13,2 Hz with an amplitude 1mm, - from 13,2 to 80 Hz with acceleration 0,7 g The protection rate provided by US -05 hull from solid objects and liquid according to GOST IP US-05 is resistant to impacts with acceleration 5,0 g and frequency in the range from 40 to 80 impacts per minute, can withstand at least 1000 ±10 impacts US-05 is related to electromagnetic compatibility elements important for safety of group III, functionality quality criterion A in accordance to GOST Р US-05 meets the seismic resistance requirements НП and RD for seismic impacts up to grade 7 of MSK-64 scale for 30 m height above the ground US-05 has the class I of electric shock protection according to GOST US-05 meets the fire protection requirements of GOST with the probability of fire /year US-05 is resistant to the decontamination agents: - boric acid (Н 3 ВО 3 ) 16 g, sodium thiosulphate (Na 2 S 2 O 3 5H 2 O) 10 g, distilled water up to 1 l; - tri-sodium phosphate or sodium hexametaphosphate 10 to 20 g/l in water (any synthetic detergents); - 5 % solution of citric acid in rectified ethyl alcohol for internal surfaces of electronic parts US-05 mass, including feeding adapter no more than 2 kg US-05 sizes no more than mm US-05 does not contain precious materials. 3

4 1.3 Reader components All components of US-05 are in the compact hermetic case made of shock-resistant plastic. 1.4 Reader design and operation US-05, COM-port of which is connected by the cable with, constantly sends the periodic query signal to the reader. US-05 converts electrical query signal into infrared radiation pulses. In the event of working dosimeter in the proper mode is inserted into US-05, it receives infrared query signal and sends the light signal in response about the readiness for data exchange US-05 converts light response signal into electric signal, which is sent to US-05 by the cable. After contact is established data exchange takes place according to reader and PC algorithms. The beginning and the end of data exchange is signaled by a sound from dosimeter. 1.5 Marking and sealing The front panel of US-05 contains the following marks: - trade name or manufacturing plant brand - unit designation; - casing protection; - unit ordinal number according to manufacturing plant numbering scheme; - manufacturing date The place and the technology of US-05 marking are in accordance to design documentation US-05 is sealed according to design documentation. 1.6 Packing Internal packing meets the requirements of GOST for group III protection type В3-0, packing type ВУ Packing is performed in closed ventilated areas with environmental temperature from +15 to + 40 С, relative humidity 80 % for +20 С and corrosion-active agents concentration limit for atmosphere type I according to GOST INTENDED USE 2.1 Operational limits US-05 is intended to work in a living area conditions PC, to which US-05 is connected, must be fed with 220 V, 50 Hz uninterruptable power supply and a filter. 2.2 Preparing reader for operation Insert connection cable of US-05 into PC COM-Port Connect feeding adapter to the 220 V, 50 Hz mains. Connect the feeding adapter cable to the corresponding connector of US-05. Feeding proper state will be confirmed by red indicator in the upper-right conner of US-05 front panel Turn PC on. Launch «DKG-05D Tools» software from CD included. It is necessary to read operation manual of this software which is included into Help option of the software. 4

5 2.3 Product usage Insert dosimeter into receiving interface of US Dosimeter will send a sound signal of 30 ms length, which means that it is ready for data exchange, you will see the value of dosimeter battery voltage on its display. Continue operation according to operation manual DKG-05D ФВКМ РЭ. «DKG-05D Tools» software provides: - dosimeter identification; - viewing measurements results of the dosimeter; - viewing and changing operating settings and calibration parameters of the dosimeter; - receiving, viewing and saving the archive content to a file; - control the operation modes of the dosimeter. 3 TECHNICAL MAINTENANCE 3.1 Overall notes Technical maintenance of US-05 is performed to keep it in the safe and working state during the lifetime. 3.2 Safety precautions Before starting to work with US-05 it is necessary to read this operation manual During the operation it is necessary to act according to «Safety rules of electric equipment operation» and «General rules of radiation safety (ОСПОРБ-99) СП » and «Radiation safety standards (НРБ-99) СП ». 3.3 Technical maintenance order Technical maintenance is divided into routine and periodic Routine technical maintenance Routine technical maintenance is periodic check of US-05 for detecting and removing any factors, that can affect functionality and safety. During the maintenance it is necessary to check the condition of spring contact group in the receiving slot of the reader Periodic technical maintenance Periodic technical maintenance is a check of overall technical state of US Decontamination Decontamination of US-05 if performed according to work rules of the plant. Outer surfaces are decontaminated by the solutions 1) and 2) according to After processing the surface with decontaminating solution it is necessary to wipe it with a tatters, wetted in a distilled water and then dry with filter paper. Contacts and connectors are decontaminated by the solution 3) according to Additional processing with distilled water and filter paper is not required. 4 ROUTINE REPAIRS 4.1 Possible malfunctions of US-05 and methods of their repairing are listed in table

6 Table 4.1- Possible malfunctions of US-05 and methods of their repairing Malfunction Possible cause Method of repairing After plugging the feeder there's no red indicator light of US-05. US-05 does not work properly No connection between dosimeter and PC 5 STORAGE Feeder is malfunctioning No good contact between spring contact group of US- 05 with charging contact group of dosimeter Replace the feeder Restore the contact 5.1 US-05 before the operation must be stored in a closed storage with natural ventilation. It is allowed to store US-05 in non-wormed areas without climate control. Storage conditions of US-05 in manufacturer's pack must meed the requirements of 3 (G3) according to GOST 15150: - ambient air temperature..... from + 5 to +40 С; - air relative humidity % at 25 ºС; There must be no dust, acid or alkali vapours, aggressive gases and other corrosive substances in a storage area. Storage area must prevent direct sunlight to US-05 in a pack. 6 TRANSPORTATION 6.1 US-05 in manufacturer's pack can be transported by any standard means to any distances: - transportation by train must be done in closed clean cars; - if transported in open carriers the packs must be protected by water-proof material; - if transported by air carrier packs must be placed into hermetic warmed area; - if transported by ship packs must be placed into hold. 6.2 The placement of packs must provide steadiness and protection from displacement and impacts. 6.3 The requirements placed on the packing boxes must be met during load and unload. 6.4 Transportation conditions are as follows: - temperature.... from minus 50 to +50 С; - humidity..... up to 98 % at +35 С; - sine vibrations..... in frequency range from 10 to 500 Hz with amplitude 0,35 mm if frequency is lower than crossover frequency, 5,0 g if higher than crossover frequency (group F3 according to GOST ). 7 UTILIZATION 7.1 At the end of lifetime of US-05 (and all equipment in its package), before sending it to repairs or checking it is necessary to check radioactive pollution of surfaces. Criteria for decontamination are listed in 3.11 ОСПОРБ Decontamination must be performed with SAS in case, when level of radioactive pollution can be lowered to acceptable values (table 8.9 НРБ-99, , ОСПОРБ-99). 7.3 According to 3.7 SPORO-2002 it is allowed to use surface absorbed dose power (0.1m) as criterion for decontamination of product polluted by unknown gamma radionuclides. 6

7 7.4 In case of excess of dose rate 0,001 mgy/h (1 μsv/h) over background after decontamination or surface radioactive pollution level excess, the product must meet the requirements of radioactive waste (RAW). RAW is a subject for classification according to 3 СПОРО-2002 and decommissioning according to 3.12 СПОРО Product allowed to continue operation after decontamination is a subject for repairs or replacement in case of non-repairability. Non-repairable product without surface radioactive pollution level excess must be disassembled to prevent its operation, and sent to special areas for waste. 7.6 The product with expired lifetime that was allowed for operation after decontamination is a subject for technical examination. In case of satisfactory condition the product is a subject for next lifetime determination. 7

Instruction Manual. Window Wiper AFW900. (Read carefully before use)

Instruction Manual. Window Wiper AFW900. (Read carefully before use) Instruction Manual Window Wiper AFW900 (Read carefully before use) When using electrical appliances, basic precautions should always be followed, including the fact READ ALL INSTRUCTIONS IN THIS MANUAL

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018 USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and

More information

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual Instruction Manual Option Card for Frequency Divider Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual and understand the description

More information

How To Use A Power Supply Unit (Upu)

How To Use A Power Supply Unit (Upu) BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Installation and safety instructions for AC/DC built-in devices

Installation and safety instructions for AC/DC built-in devices The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further

More information

Infrarot-Bewegungsmelder IP44

Infrarot-Bewegungsmelder IP44 Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion

More information

User s Manual AURORA 1.2K/2.2K

User s Manual AURORA 1.2K/2.2K User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable

More information

Radiant Temperature Sensor TY7321

Radiant Temperature Sensor TY7321 AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional

More information

64-CHANNEL INTEGRATED AMPLIFIER

64-CHANNEL INTEGRATED AMPLIFIER Panasonic 64-CHANNEL INTEGRATED AMPLIFIER Operating Instructions P/N: SU-MED640E Caution for AC main lead FOR YOUR SAFETY, PLEASE READ THE FOLLOWING TEXT CAREFULLY This product is equipped with 2 types

More information

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6 User s manual Index Safety Warnings... 2 1 Introduction... 3 2 General Characteristics... 4 3 Receipt and site selection... 4 4 EXTERNAL

More information

SPL 2-00/-01 OPERATION INSTRUCTIONS

SPL 2-00/-01 OPERATION INSTRUCTIONS SPL 2-00/-01 OPERATION INSTRUCTIONS Powerline Ethernet Adapter 500 Mbps EN Read and keep Operation Instructions SPL 2-00/-01 Safety Notes Do NOT use this product near water, for example, in a wet basement

More information

TM Advanced Tracking Technologies, Inc. 2003 ATTI All rights reserved

TM Advanced Tracking Technologies, Inc. 2003 ATTI All rights reserved TM Advanced Tracking Technologies, Inc. 2003 ATTI All rights reserved Copyright 2003, Advanced Tracking Technologies, Inc. All rights reserved. No part of this publication may be reproduced or transmitted

More information

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy. Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

SEISMIC VELOCITY TRANSDUCER T1-40

SEISMIC VELOCITY TRANSDUCER T1-40 SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute

More information

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes dedicated KVM switch and rackmount screen technology User Manual RK-2d / RK-2t 1U Short Depth Keyboard Drawer Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

CL90i. 77-021 Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

CL90i. 77-021 Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser 3 - Beam Self-Leveling Cross Line Laser CL90i 77-01 Please read these instructions before operating the product Self-Leveling GB D F I E PT NL DK SE FIN NO PL GR CZ RU HU SK SI BG RO EE LV LT Contents

More information

CELO5. User & Installation Manual. www.audac.eu

CELO5. User & Installation Manual. www.audac.eu CELO5 User & Installation Manual www.audac.eu 2 Introduction 5 High-end Slim Ceiling Speaker The CELO5 is the 5 version of AUDAC s CELO High-end Slim ceiling speaker series with an RMS power of 50 Watt

More information

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or

More information

Lithium Ion Battery Specifications

Lithium Ion Battery Specifications Lithium Ion Battery Specifications Type: Cylindrical Lithium Iron Phosphate Battery Mode: LFP-26650-3300 AA Portable Power Corp. Prepared by Checked by Approved by 1 . Product Specifications Type ------------

More information

How To Use A Cdm250 Digital Multimeter

How To Use A Cdm250 Digital Multimeter User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this

More information

NFC Communication Tray Model: HHX-IT3-Z

NFC Communication Tray Model: HHX-IT3-Z INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8

More information

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1 No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------

More information

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

REGULINE 600VA / 1000VA REGULATOR USER MANUAL REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate

More information

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE

More information

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS + Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,

More information

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,

More information

Meaco 30L and Meaco 40L dehumidifier instruction manual

Meaco 30L and Meaco 40L dehumidifier instruction manual Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS

More information

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10 Business Audio System: Music & Messaging MP3 Player by Grace Digital Audio User Guide Model No. GDI-USBM10 User Guide Contents Introduction 2 Safety & General Use Information 2 Features 3 Set Up & Operation

More information

Care and Handling of Your VAIO Computer

Care and Handling of Your VAIO Computer Care and Handling of Your VAIO Computer Proper Handling Use your computer on a clean dry, stable surface. Use only specified peripheral equipment and interface cables or you may experience problems. When

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Getting Started Getting Started with the Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 You only need a few minutes to get started

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

User s Manual. Copyright 2014 Trick Technologies Oy

User s Manual. Copyright 2014 Trick Technologies Oy User s Manual Copyright 2014 Trick Technologies Oy Catchbox Pro Module Catchbox Cover Contents 1 Safety Instructions...4-5 2 Quick Start... 6-15 3 Product Description... 16-18 Overview...16 Compatibility...17

More information

User Manual. CFG253 3 MHz Function Generator 070-8362-04

User Manual. CFG253 3 MHz Function Generator 070-8362-04 User Manual CFG253 3 MHz Function Generator 070-8362-04 Copyright Tektronix, Inc. 1993. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information

More information

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal. Instructions: Part I. Charge the Power Bank Method 1 Charge the Power Bank via Computer USB Terminal. Connect the provided USB power cable to the micro- USB plug connector tip (the tip marked "M10"). Step

More information

TABLE OF CONTENTS QUICK START... 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS... 3 REMOTE CONTROL FUNCTIONS..

TABLE OF CONTENTS QUICK START... 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS... 3 REMOTE CONTROL FUNCTIONS.. TABLE OF CONTENTS QUICK START........ 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS..... 3 REMOTE CONTROL FUNCTIONS..4 DIGITAL PHOTO FRAME NAVIGATION........5 OSD MENU FUNCTIONS..6

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing Introduction: NS-205-IP67 Ethernet Switches are designed for use in industrial waterproof/harsh environments. The rugged packaging

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

PU-USBX. USB over Ethernet Extender OPERATION MANUAL PU-USBX USB over Ethernet Extender OPERATION MANUAL Safety Precautions Please read all instructions before attempting to unpack or install or operate this equipment, and before connecting the power supply.

More information

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0. ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS FCC COMPLIANCE STATEMENT FOR AMERICAN USERS This equipment has been tested and found to comply with the limits for a CLASS A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed

More information

Changers Kalhuohfummi User Manual

Changers Kalhuohfummi User Manual Changers Kalhuohfummi User Manual Contents 02 Contents 1. The Changers Kalhuohfummi an introduction to your solar battery 2. Introduction to energy tracking 3. Content and compatibility 4. Controls and

More information

TIG INVERTER INSTRUCTION MANUAL

TIG INVERTER INSTRUCTION MANUAL TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4

More information

PD 100A. Printing data system

PD 100A. Printing data system PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep

More information

If you are familiar with these matters, then you can use this manual as a work of reference.

If you are familiar with these matters, then you can use this manual as a work of reference. PRODUCT CODE : MFX0370 VERSION : 1.0 DATE : 16.12.2013 User documentation MAGICFX Confetti Gun 1. FOREWORD Congratulations! You have bought a great new product from MAGICFX. The MAGIC FX Confetti Gun is

More information

Surface Mounting Relay

Surface Mounting Relay Surface Mounting Relay Surface Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm Subminiature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density

More information

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System IR-PRO Operation Guide IR-PRO Professional Infrared Code Capture System Introduction The IR-PRO is an infrared code capture system that is specifically designed for system integration professionals. Unlike

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

aseries A13B Mini Bullet Camera User Manual

aseries A13B Mini Bullet Camera User Manual aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView

More information

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools APPENDIX II Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools (Prepared by Environmental Protection Department) 1. Introduction The Waste Disposal (Chemical

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

User manual Rev 1.3 Contents

User manual Rev 1.3 Contents User manual Rev 1.3 Contents 1. Introduction...4 2. System specifications...5 2.1.. General overview...5 2.2. Maximum capacity...6 2.3. Electrical specifications...6 2.4. Mechanical specifications...6

More information

PowlVac Vacuum Integrity Tester

PowlVac Vacuum Integrity Tester Instructions IB-60025B PowlVac Vacuum Integrity Tester POWELL ELECTRICAL MANUFACTURING COMPANY 8550 MOSLEY DRIVE HOUSTON, TEXAS 77075 USA PHONE (713) 944-6900 FAX (713) 947-4453 www.powellelectric.com

More information

Congratulations! Thank you!

Congratulations! Thank you! TM-47 ORDERCODE D1370 Congratulations! You have bought a great, innovative product from DAP Audio. The DAP Audio Microphone range brings excitement to any venue. Whether you want simple plug-&-play action

More information

CHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER

CHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER 000000000!"!##%!"!# & ( ) * + *, ( (-#(. *, )*/.( 0 - % ) ++ )%++) ( ++1 CHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER Page 1 / 30 TEQCO597C B. Charging levels and modes Page 4 / 30 C. Plugs /

More information

Product Discontinuation Notices

Product Discontinuation Notices PRODUCT NEWS Product Discontinuation Notices Code Readers / OCR Issue Date March 2, 2015 No. 2015027CE Discontinuation Notice of 2D Code Reader (Fixed Type) V530-R160/R2000 series and the peripherals F150-[][][]-2D

More information

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc.

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc. Quick Guide DS1000CA Series Oscilloscope Aug. 2011 Technologies, Inc. Guaranty and Declaration Copyright 2011 Technologies, Inc. All Rights Reserved. Trademark Information is a registered trademark of

More information

Lava. Precision Solutions. Site Planning and Installation Guide

Lava. Precision Solutions. Site Planning and Installation Guide Lava Precision Solutions Site Planning and Installation Guide TABLE OF CONTENTS Table of Contents Introduction...........................................................................................

More information

Tel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks

Tel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks Tel.X Ni-Cd battery The compact maintenance-free solution for telecom networks Tel.X, delivering high-energy performance in a compact maintenance-free package Tel.X: guaranteed power continuity for remote

More information

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living 2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use

More information

MOBILE WATER TREATMENT FACILITY UMUV 01

MOBILE WATER TREATMENT FACILITY UMUV 01 MOBILE WATER TREATMENT FACILITY UMUV 01 January 10 Basic description of facility VODASERVIS s.r.o. UMUV 01 is a multi-purpose mobile water treatment facility which enables treatment from different sources

More information

8001782 Owner s Manual

8001782 Owner s Manual 8001782 Digital Infrared Thermometer Owner s Manual Introduction This instrument is a portable, easy to use compact-size digital thermometer with laser sighting designed for one hand operation. The meter

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators Technical Note: 9 Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators 1- Introduction The VALIDATOR, model TN-ID-60, is a compact, and stand-alone dosimetry

More information

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN

More information

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER PSUM These technical specifications determinate a range of manufactured sizes and models of fire shutters (further only shutters)

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

SATEX SA 230. - Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND

SATEX SA 230. - Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND - Manual SATEX SA 230 PRECISION BALANCE Weegtechniek holland b.v. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND Tel. + 31 36 522 20 30 Fax. + 31 36 522 20 60 Email info@satex.nl Website www.satex.nl page

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied

More information

dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes

dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October 2002 Information

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

Mechanical Engineering and Material Handling Aspects of NSDF

Mechanical Engineering and Material Handling Aspects of NSDF Mechanical Engineering and Material Handling Aspects of NSDF R. K. Gupta and A. K. Singh BARC- IAEA Regional Training Course on Development of Near Surface Disposal Facility February 15-19, 2010 Mumbai,

More information

Power supply unit Model: PAC-SC50KUA

Power supply unit Model: PAC-SC50KUA Building Air Conditioning Control System Power supply unit Model: PAC-SC50KUA Installation Manual Contents 1. Safety precautions... 1 2. Product feature... 2 1. Specification... 2 2. Appearance... 2 3.

More information

Instruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Instruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function Important Safeguards READ ALL INSTRUCTIONS BEFORE USE. Instruction Manual Automatic Dispensing Hot Water Pot with Reboil Function Image of SP-3015 & SP-3815 SP-3015: 3.0L SP-3815: 3.8L SP-3017: 3.0L (Stainless

More information

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase.

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase. LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro online UPS 10-100 kva three-phase / single-phase 10-800 kva three-phase / three-phase LOCAL AREA NETWORKS (LAN) INTERNET CENTERS (ISP/ASP/POP) ELECTRO-MEDICAL

More information

CLASSIFICATION NOTES

CLASSIFICATION NOTES CLASSIFICATION NOTES Type Approval, Installation and Testing of Water Level Detectors on Bulk Carriers and Single Hold Cargo Ships other than Bulk Carriers General Information This edition of the classification

More information

INFO-0545 RADIOISOTOPE SAFETY MONITORING FOR RADIOACTIVE CONTAMINATION

INFO-0545 RADIOISOTOPE SAFETY MONITORING FOR RADIOACTIVE CONTAMINATION INFO-0545 RADIOISOTOPE SAFETY MONITORING FOR RADIOACTIVE CONTAMINATION 1. INTRODUCTION This document provides general guidance for monitoring and controlling radioactive contamination, and relating the

More information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273

More information

AC and Pulse Film Foil Capacitors KP Radial Potted Type

AC and Pulse Film Foil Capacitors KP Radial Potted Type AC and Pulse Film Foil Capacitors KP Radial Potted Type 0.5 L max. W max. Marking H max. FEATURES 5 mm lead pitch, supplied loose in box taped in ammopack or reel Material categorization: for definitions

More information

IFC 070 Technical Datasheet

IFC 070 Technical Datasheet IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer

More information

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options. MX MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Tel.X Ni-Cd battery. The compact solution for stationary applications

Tel.X Ni-Cd battery. The compact solution for stationary applications Tel.X NiCd battery The compact solution for stationary applications Tel.X, delivering highenergy performance in a compact maintenancefree package Tel.X: guaranteed power continuity for remote or hard to

More information

SES-FA1 USER MANUAL. Sescom SES-FA1 2-Channel Line Level Audio Over Fiber Extender Kit

SES-FA1 USER MANUAL. Sescom SES-FA1 2-Channel Line Level Audio Over Fiber Extender Kit SES-FA1 USER MANUAL Sescom SES-FA1 2-Channel Line Level Audio Over Fiber Extender Kit Sescom SES-FA1 2-Channel Line Level Audio Over Fiber Extender Kit Perfect for many types of studios, broadcasting,

More information

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,

More information

Liquid Leakage Sensor Amplifier

Liquid Leakage Sensor Amplifier 9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such

More information

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,

More information