MANTA Piston Distributor for Oil and Fluid Grease



Similar documents
SINGLE LINE CRENTRALIZED LUBRICATION SYSTEM

Adams. Spray Lubrication

In addition to the basic models, it is also possible for the units to be outfitted with add-ons.

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Single- and Multi-circuit Pumps

4/2-Way Pneumatic Solenoid Valve

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Suction assembly for l IBC and 205 l drums mm suction tube Suction assembly for tanks mm suction tube.

3/2-way Solenoid Valve, direct-acting, NC or NO

Pressure Relief Valves SPV, SPVF

PUMP AND MOTOR DIVISION

Single sub-base valve

...een product van BEKA

Proportional pressure regulators VPPE

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

Lubricant distributors

GROENEVELD AUTOMATIC GREASING SYSTEMS

Unit 24: Applications of Pneumatics and Hydraulics

3/2-way Mini Solenoid Valve

2/2 and 3/2 Way Size 6 Seat Valves

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Unit 24: Applications of Pneumatics and Hydraulics

Assisted lift operated 2/2-way solenoid valves Type EV250B

AIR OPERATED OIL PUMPS AND KITS

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

3/2- and 2/2-way cartridge valve type BVE

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Radial piston pumps type R and RG

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Centro-Matic Automatic Lubrication Systems System Controls

Lincoln Multi-line and progressive systems

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

System 8. ü ( System 8

G1/4 Q8. Standard with biased position

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Condensate water pump with neutralisation system

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

Complete Systems & Parts Automatic Oiler & Grease Bank

Product catalogue, pipe and sewer cleaning systems

HERZ-Thermal Actuators

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Electric Rotary Actuator - On/Off or programmable control actuator

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)

Product series DSA, DSB, DSC, DSD

Hydraulic Control Solutions

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

Please also see 10 golden rules for correct Saniflo installation on

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Waste Oil Handling, Spill Containment & Lighting

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Directional seated valves type VP 1

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

MEMBRANE VACUUM MINI PUMPS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Flow divider (flow distributor), type TQ

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Operating Instructions Parts List Manual Scissor Lift Pallet Truck

SunMaxx Solar Filling Station Operating Instructions

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Norbro Series 40R Pneumatic Actuator Double Acting or Spring Return

1300 MAXTRAK SPECIFICATION

ECOCIAT. Domestic hot water heat recovery unit

ONE STAGE LIGHT OIL AND KEROSENE BURNERS

Type 3353 Angle Seat Valve

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

The ACCU-LUBE Micro-Lubricating System for external and internal lubrication

Specifications for Volkswagen Industrial Engine

15/40/80CN Series Medium Pressure Filters

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Combi switchbox with integrated 3/2 way pilot valve

Variable Displacement Pump AA10VSO

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Hydraulic control unit series

Unit 24: Applications of Pneumatics and Hydraulics

15CI and 25CI Reversing Motor Pumpset Owner's Manual

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

Unit 24: Applications of Pneumatics and Hydraulics

TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL

SOLENOID VALVES AND PNEUMATIC VALVES

Electro-Pneumatic Bus Door Control Mechanism

VOYAGER 570G. 744A Sprayer Control

DSL & SVK Lubricators Product Specs and Ordering

Number Wheeler P/N Description Set Rex P/N Notes

Transcription:

MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube points are determined by exchangeable metering nipples. The metered amount is indicated on the individual nipples. The amount needed to cover the total oil demand can then be further regulated via the lubricating frequency. To meet the required quantities and comply with spatial constraints it is possible to choose among four distributor groups that differ in terms of their metering ranges and sizes. The functional principle of the groups is the same, but there are differences in design. Different distributor groups can be used in one installation. Distributor for Oil group Quantity cm³ 3200 0,01 0,03 0,06 0,1 0,16 3400 0,01 0,03 0,06 0,1 0,16 3500 0,1 0,2 0,4 0,6 3900 0,2 0,4 0,6 1,0 1,5 Distributor for fluid grease group 3410 0,01 0,03 0,06 0,1 Quantity cm³ 3510 0,1 0,2 0,3 3910 0,1 0,2 0,3 3210 0,01 0,03 0,06 0,1 0,2 0,3

Piston distributor for oil group 3200 0,01 0,16 cm³ tube 4 dose Number of outlets: 1 2 3 5 3200-X-XXXXX-X 5 4 3 2 1 washer Quantity 2 ): 0 0 cm³ - outlet closed 1 0,01 cm³ 2 0,03 cm³ 3 0,06 cm³ 4 0,10 cm³ 5 0,16 cm³ 2 )marking on the metering nipple mounting thread D1 B C M14x1,5 Number of lubrication points 2 3 5 2 3 5 Manifold thread D1 Main line B1 H1 H2 L 6 13 17 10,5 M14x1,5 8 18 20 11 Order- No Quantity cm³ marking on the metering nipple 6311 0,01 1 6312 0,03 2 6313 0,06 3 6314 0,10 4 6315 0,16 5 Piston distributor 52 65 65 61 74 74 Order example: Distributor group: 3200 with 3 outlets key: 3 marking from the right to the left: 0,06-0,10-0,03 cm³ 3 4 2 Mounting thread of the distributor last B 3200-3-342-B operating pressure: 10 45 bar medium: oil viscosity: 32 to 2000 mm²/s temperature range: +0 C to + 70 C perm. residual pressure: max. 1,5 bar For one lube point the metering unit can only be used with a tee piece. 2 08/13

Piston Distributor for Oil group 3400 0,01 0,16 cm³ Number of outlets : 1 2 3 5 3400-X-XXXXX 5 4 3 2 1 Piston Distributor 1-port No. 3400-1-X Piston Distributor 2-ports No. 3400-2-XX Quantity 2 ): 0 0 cm³ - outlet closed 1 0,01 cm³ 2 0,03 cm³ 3 0,06 cm³ 4 0,10 cm³ 5 0,16 cm³ Order example: Distributor group: 3400 with 3 outlets key: 3 marking from the right to the left: 0,06-0,10-0,03 cm³ 3 4 2 3400-3-342 2 )marking on the metering nipple operating pressure: 10 45 bar medium: oil viscosity: 32 to 2000 mm²/s temperature range: +0 C to + 70 C perm. residual pressure: max. 1,5 bar Piston Distributor 3-ports Nr. 3400-3-XXX Piston Distributor 5-ports No. 3400-5-XXXXX 3 08/13

Piston distributor for oil group 3500 0,10 0,60 cm³ 3500-X-XXXXX Piston Distributor 1-port No. 3500-1-X Piston Distributor 2-ports No. 3500-2-XX Number of outlets : 1 2 3 5 Quantity 2 ): 0 0 cm³ - outlet closed 4 0,10 cm³ 5 0,20 cm³ 6 0,40 cm³ 7 0,60 cm³ Order example: Distributor group: 3500 with3 outlets key: 3 marking from the right to the left: 0,60-0,20-0,40 cm³ 7 5 6 3500-3-756 2 )marking on the metering nipple 5 4 3 2 1 operating pressure: 10 45 bar medium: oil viscosity: 32 to 2000 mm²/s temperature range: +0 C to + 70 C perm. residual pressure: max. 1,5 bar Piston Distributor 3-ports No.3500-3-XXX Piston Distributor 5-ports No. 3500-5-XXXXX 4 08/13

Piston Distributor for oil group 3900 0,20 1,50 cm³ 3900-X-XXXXX Piston Distributor 1-port No. 3900-1-X Number of outlets : 1 2 3 Quantity 2 ): 0 0 cm³ - outlet closed 5 0,20 cm³ 6 0,40 cm³ 7 0,60 cm³ 8 1,00 cm³ 9 1,50 cm³ 2 )marking on the metering nipple 5 4 3 2 1 Order example: Distributor group: 3900 with 3 outlets key: 3 marking from the right to the left: 0,20 0,60 1,50 cm³ 5 7 9 3900-3-579 Piston Distributor 2-ports No. 3900-2-XX Piston Distributor 3-ports No. 3900-3-XXX 02/07 operating pressure: 10 45 bar medium: oil viscosity: 32 to 2000 mm²/s temperature range: +0 C to + 70 C perm. Residual pressure: max. 1,5 bar 5 08/13

Piston Distributor for grease NLGI 000, 00 group 3410 0,01 0,10 cm³ 3410-X-XXXXX Piston Distributor 1-port No. 3410-1-X Number of outlets : 1 2 3 5 Quantity 2 ): 0 0 cm³ - outlet closed 1 0,01 cm³ 2 0,03 cm³ 3 0,06 cm³ 4 0,10 cm³ 2 )marking on the metering nipple 5 4 3 2 1 Piston Distributor 2-ports No. 3410-2-XX Order example: Distributor group: 3410 with 3 outlets key 3 marking from the right to the left: 0,06-0,10-0,03 cm³ 3 4 2 3410-3-342 operating pressure: 10 45 bar medium: grease NLGI 000, 00 temperature range: +0 C to + 60 C perm. residual pressure: max. 1,5 bar Piston Distributor 3-ports No. 3410-3-XXX Piston Distributor 5-ports No. 3410-5-XXXXX 6 08/13

Piston Distributor for grease NLGI 000, 00 group 3510 0,10 0,30 cm³ Piston distributor 1-port No. 3510-1-X Number of outlets : 1 2 3 5 3510-X-XXXXX 5 4 3 2 1 Quantity 2 ): 0 0 cm³ - outlet closed 2 4 0,10 cm³ )marking on the 5 0,20 cm³ metering nipple 6 0,30 cm³ Piston distributor 2-ports No. 3510-2-XX Order example: Distributor group: 3510 with 3 outlets key: 3 marking from the right to the left: 0,20-0,10-0,30 cm³ 5 4 6 3510-3-546 operating pressure: 10 45 bar medium: grease NLGI 000, 00 temperature range: +0 C to + 60 C perm. residual pressure: max. 1,5 bar Piston distributor 3-ports No. 3510-3-XXX Piston distributor 5-ports No. 3510-5-XXXXX 7 08/13

Piston Distributor for grease NLGI 000, 00 group 3910 0,10 0,30 cm³ Number of outlets : 1 2 3 3910-X-XXX 3 2 1 Piston distributor 1-port No. 3910-1-X Quantity 2 ): 0 0 cm³ - outlet closed 4 0,10 cm³ 5 0,20 cm³ 6 0,30 cm³ 2 )marking on the metering nipple 5 6 Order example: Distributor group: 3910 with 2 outlets key: 2 marking from the right to the left: 0,20 0,30 cm³ 5 6 3910-3-56 2 1 operating pressure: 10 45 bar medium: grease NLGI 000, 00 temperature range: 0 C to + 60 C perm. residual pressure: max. 1,5 bar Piston distributor 2-ports No. 3910-2-XX 5 5 5 3 2 1 Piston distributor 3-ports No. 3910-3-XXX 8 08/13

Metering units for direct connection to the lube point For oil and grease NLGI 000, 00 group KVF- 3210 KVF 3210 X-X-X-X Form Tube Quantity d A - Form A B - Form B C - Form C D - Form D E - Form E 4-4 only for oil 6-6 2-0,03 cm³ 3-0,06 cm³ 4-0,10 cm³ 1 M8x1K 2 K 3 G1/8 K Example: Metering units group: 3210 Form A : A screws for 6 mm tube: 6 quantity 0,10 cm³: 4 d - K: 2 3210-A-6-4-2 operating pressure: medium: 18 50 bar oil and grease NLGI 000, 00 temperature range: 0 C to + 70 C perm. residual pressure: max. 3 bar 9 08/13

Metering units for direct connection to the lube point For oil and grease NLGI 000, 00 group KVF- 3210 3 4 KVF 3210 X-X-X Form Tube Quantity Form F - F Form G - G 4-4 only for oil 6-6 2-0,03 cm³ 3-0,06 cm³ 4-0,10 cm³ Form H - H 4-0,10 cm³ 5-0,20 cm³ 6-0,40 cm³ Example: Metering units group: 3210 Form F : F screws for 6 mm tube: 6 quantity 0,10 cm³: 4 3210-F-6-4 operating pressure: medium: 18 50 bar oil and grease NLGI 000, 00 Temperature range: 0 C to + 70 C perm. residual pressure: max. 3 bar 10 08/13

Piston Pump for oil and grease hand operated Type EHP Hand operated pump Output per stroke: 7, 15 or 30 cm³ pressure max.: 30 bar perm residual pressure: 0,5 to 1 bar medium: oil viscosity: 20 to 3000 mm²/s (cst) operating temperature: -10 C to + 80 C reset valve: 25 bar Reservoir Capacity: 0,5 or 1,25 Litres Material: Aluminium Oil indicator: optical EHP-X-X-X Capacity 5 0,5 Litres 6 1,25 Litres Output per stroke 1 7 cm³ 2 15 cm³ Reset valve 0 - without 5 - with reset valve 6 1,25 Litres 3 30 cm³ 0 - without 5 - with reset valve Example: hand operated pump Type: EHP capacity 1,25 Litres: 6 output 7 cm³/stroke: 1 with reset valve: 5 EHP-6-1-5 11 08/13

Gear pump for oil Type EPA P Illustrated: EPA-3 Gearpump 3 l Capacity. EPA-X-X-X-X Pump Discharge: 0,2 or 0,5 l/min Pressure: max.: 30 bar medium: oil viscosity: 50 to 1500 mm²/s (cst) operating temperature: max. 60 C Reservoir Capacity: 3 or 6 Litres Material: Plastic, transparent Motor Voltage: 3 ph 230/400V 50Hz 0,66/0,38A 3 ph 276/480V 60Hz 0,75/0,43A Power rating: 70 W Speed: 50Hz:2730/60Hz:3200 min -1 Type of enclosure: IP-44 Capacity Discharge Float switch Voltage 3-3 Litres 6-6 Litres 2-0,2 l/min 5-0,5 l/min 0 - none 5 - min 6 - min and max 3-230/400V 50Hz 276/480V 60Hz Float switch voltage max.: 250V AC Power max. 0,8A Circuit diagram: Example: Pump Type: EPA Capacity 3 Litres: 3 Discharge 0,2 l/min: 2 Float switch min : 5 Motor 230/400 V: 3 EPA-3-2-5-3 12 08/13

Gear pump for oil Type EPA P Pump Discharge: 0,2 or 0,5 l/min Pressure: max.: 30 bar medium: oil viscosity: 50 to 1500 mm²/s (cst) operating temperature: max. 60 C Reservoir Capacity: 3 or 6 Litres Material: Plastic, transparent Motor Voltage: 3 ph 230/400V 50Hz 0,66/0,38A 3 ph 276/480V 60Hz 0,75/0,43A Power rating: 70 W Speed: 50Hz:2730/60Hz:3200 min -1 Type of enclosure: IP-44 Illustrated: EPA Gearpump 6 l Capacity Hydraulic diagram Float switch voltage max.: 250V AC Power max. 0,8A Circuit diagram: 1. reservoir 2. motor 3. gear pump 4. low level switch 5. pressure control valve 6. relief valve 7. fill filter 8. suction filter 13 08/13

Gear pump for oil Type EPA-A without tank Pump Discharge: 0,2 or 0,5 l/min pressure max.: 30 bar medium: oil Viscosity: 50 to 1500 mm²/s (cst) Operating temperature: max. 60 C Suction height: max. 500 mm remaining pressure: 0,4 to 1,6 bar Discharge L L1 Motor Voltage: 3 ph 230/400V 50Hz 0,66/0,38A 3 ph 276/480V 60Hz 0,75/0,43A Power: 70 W Speed: 50Hz:2730/60Hz:3200 min -1 Protection:IP-44 0,2 l/min 197 34 0,5 l/min 201 38 EPA-A-X-X-X P = output E = input R = return directly to tank R1 = alternative return Type Discharge Voltage 0 separate mounting 2 mounting on a tank 2-0,2 l/min 5-0,5 l/min 3-3 ph 230/400V 276/480V Example: Pump Type: EPA-A Mounting on a tank/ reservoir: 2 discharge 0,2 l/min: 2 motor: 3 EPA-A-2-2-3 14 08/13

Gear pump for grease Type EPA-F P Illustrated: EPA-F-3 Pump With 3 litres reservoir. EPA-F-X-X-X Pump Discharge: 0,2 l/min pressure, max.: 40 bar medium: grease, NLGI-Class 000, 00 Operating temperature: max. 60 C Reservoir Capacity: 3 or 6 Litres Material: Plastic, transparent Three phase current motor Voltage: 3 ph 230/400V 50Hz 0,66/0,38A 3 ph 276/480V 60Hz 0,75/0,43A Power: 70 W Speed: 50Hz:2730/60Hz:3200 min -1 Protection: IP-44 Capacity Discharge level switch 3-3 Litres 6-6 Litres 2-0,2 l/min 0 none 5 min level switch Voltage max.: 250V AC Switch voltage max. 0,8A Example: Pump Type: EPA-F Capacity: 3 Litres: 3 Discharge: 0,2 l/min: 2 Level switch: 5 EPA-F-3-2-5 15 08/13

Manifolds Tube ø d d1 d2 d3 L1 L2 L3 L4 Order No. 6 4 1x M8x1 5,5 35 24 25 15 6721 6 4 2x M8x1 5,5 52 41 25 15 6722 6 4 3x M8x1 5,5 68 57 25 15 6723 6 4 4x M8x1 5,5 84 73 25 15 6724 6 4 5x M8x1 5,5 100 89 25 15 6725 6 4 6x M8x1 5,5 116 105 25 15 6726 6 4 7x M8x1 5,5 132 121 25 15 6727 6 4 8x M8x1 5,5 148 137 25 15 6728 8 4 1x M8x1 5,5 35 24 25 15 6731 8 4 2x M8x1 5,5 52 41 25 15 6732 8 4 3x M8x1 5,5 68 57 25 15 6733 8 4 4x M8x1 5,5 84 73 25 15 6734 8 4 5x M8x1 5,5 100 89 25 15 6735 8 4 6x M8x1 5,5 116 105 25 15 6736 8 4 7x M8x1 5,5 132 121 25 15 6737 8 4 8x M8x1 5,5 148 137 25 15 6738 16 08/13

Manifolds Tube ø d d1 d2 d3 L1 L2 L3 L4 Order No. 6 6 1x 5,5 35 24 25 15 6781 6 6 2x 5,5 53 42 25 15 6782 6 6 3x 5,5 71 60 25 15 6783 6 6 4x 5,5 89 78 25 15 6784 6 6 5x 5,5 107 96 25 15 6785 6 6 6x 5,5 125 114 25 15 6786 6 6 7x 5,5 143 132 25 15 6787 6 6 8x 5,5 161 143 25 15 6788 8 6 M14x1,5 2x 6,5 67 50 30 20 6742 8 6 M14x1,5 3x 6,5 85 68 30 20 6743 8 6 M14x1,5 4x 6,5 103 86 30 20 6744 8 6 M14x1,5 5x 6,5 121 104 30 20 6745 8 6 M14x1,5 6x 6,5 139 122 30 20 6746 8 6 M14x1,5 7x 6,5 157 140 30 20 6747 8 6 M14x1,5 8x 6,5 175 158 30 20 6748 T-Unit for mounting a seperate metering unit D1 D2 D3 L1 L2 L3 Order No. M8x1 M8x1 14 32 36 15 6281 14 32 36 15 6282 M14x1,5 M14x1,5 18 36 44 20 6283 18 36 44 20 6284 M14x1,5 18 36 44 20 6285 17 08/13

Manifolds Tube ø d d1 d2 L1 L2 L3 L4 Order No. 8 8 M14x1,5 1x M14x1,5 49 32 35 20 6751 8 8 M14x1,5 2x 72 55 30 20 6752 8 8 M14x1,5 3x 95 78 30 20 6753 8 8 M14x1,5 4x 118 101 30 20 6754 8 8 M14x1,5 5x 147 130 30 20 6755 8 8 M14x1,5 6x 164 147 30 20 6756 8 8 M14x1,5 7x 187 170 30 20 6757 8 8 M14x1,5 8x 210 193 30 20 6758 10 10 M16x1,5 1x M16x1,5 49 32 35 20 6761 10 8 M16x1,5 2x M14x1,5 72 55 35 20 6762 10 8 M16x1,5 3x M14x1,5 95 78 35 20 6763 10 8 M16x1,5 4x M14x1,5 118 101 35 20 6764 10 8 M16x1,5 5x M14x1,5 147 130 35 20 6765 10 8 M16x1,5 6x M14x1,5 164 147 35 20 6766 18 08/13

Piston Distributor Accessoires For main line and lube line fittings Distributor fittings and screw caps Description Thread D For tube Order No. Wrap screw for double tapered ring M8x1 M14x1,5 4 6 8 8 6212 6213 6214 6215 Wrap screw for cone ring M8x1 4 6 6216 6217 Main line and lube line fittings for steel tubing Main line- and lube line fittings for plastic tubing ØD Double tapered ring Cone ring Case Screw plug M8x1 M14x1,5 4 6 8 10 12 4 6 8 10 12 4x0,85 4x1,5 4x1,3 4x1 6x1 6x1,25 8x1 8x1,5 10x1,5 10x2 6222 6223 6224 6225 6226 6232 6233 6234 6235 6236 6241 6242 6243 6244 6245 6246 6247 6248 6249 6250 6252 6253 6254 6255 Washer 8,2 10,2 12,2 14,2 6262 6263 6264 6260 Description Thread D 1 Thread D 2 M14x1,5 Order No. 6064 6065 6066 Thread to distributor M14x1,5 6067 6068 6069 Self-sealing 6070 Adapter M8x1 M14x1,5 M14x1,5 ¼ G M8x1 ⅛ G ¼ G ¼ G M14x1,5 6270 6271 6272 6273 6274 6275 6276 6277 6278 6279 6280 6290 Pressure switches 24V DC Adjustment range: 10 50 bar Thread: Order No. 2703 19 08/13

Function 1. The amount of oil intended for the lube point is stored in front of the piston in the distributor. 2. When the central lubrication pump starts delivering oil, the piston moves and the oil in front of it is fed to the lube point at a main line pressure of 10-45 bars. 3. After the pressure is relieved in the main line the distributor's piston returns to its initial position and once again lets a certain quantity of oil flow into the space in front of it. Distributor group 3200 Distributor group 3400 Distributor group 3500 and 3900 20 08/13

Single-line lubrication system with piston distributor for oil Function A pump feeds the lubricant through the main line to the piston distributors. From there it is directed to the lube points in precisely metered quantities. This takes place in a time- or pulse-controlled sequence. Planning 1. Determine the type of drive to be used for the oil pump (manual, electric for three-phase current or AC, pneumatic). 2. Select the lubricant. Then determine the pump unit and type of distributors. 3. Determine the number of lube points and define the amount of lubricant required to meet the needs of each point. Ascertain the total amount of lubricant needed per unit of time or clock pulse. Then dimension the contents of the lubricant reservoir. Choice of distributors Select the piston distributors on the basis of the metered quantity and spatial constraints. The ratio of the metered quantities in respect to each other should be the same as the consumption of the individual lube points. The total amount needed by the installation is then regulated by the number of lube cycles per unit of time. Laying an installation When installing a central lubrication system, lay the main lines and distributors in such a way that any air in the system can escape on its own via the lube points. To do so, mount the distributors at appropriate places and at the end of the installation in such a way that the connections to the lube points point upward (cf. Fig. 1). The main lines from the pump to the distributors must, if possible, be laid with a rising gradient. If lines have to be routed to distributors at lower locations, proceed in accordance with Fig. 2. Check the main-line resistance values, especially in regard to the relief routine, when specially large systems and ones with a large number of branches are involved or when highly viscous oils are used. Each distributor port may be connected to only one lube point! Do not connect the secondary line (connection: distributor lube point) to the lube point until bubble-free oil emerges at its end after repeated actuation of the pump. It might be necessary to fill long secondary lines with oil first. If a secondary line is blocked or broken, that will have no effect on the remaining lube points in the system. From the pump Fig. 1 Fig. 2 LubTechnik s.r.o. Středulinského 966/ 26 703 00 Ostrava Vítkovice Česká republika Tel./fax:+420 595 030 000 Gsm: +420 606 131 021 E-mail:prodej@lubtechnik.cz www.lubtechnik.cz 08/13