ONE STAGE LIGHT OIL AND KEROSENE BURNERS
|
|
|
- Janel Williamson
- 9 years ago
- Views:
Transcription
1 ONE STAGE LIGHT OIL AND KEROSENE BURNERS RDB SERIES RDB-R 6,8 4,6 kw RDB-R 4, 46, kw RDB.-.R, 4, kw RDB.-.R,, kw RDB,6 68,7 kw RDB. 4,, kw RDB4,7, kw The Riello RDB series of one stage light oil and kerosene burners is available in 8 basic models, with an output ranging from 6,8 to kw, in three different structures. The models are available in light oil and kerosene versions, conventional flue and balanced flue, with or without the fuel pre-heater fitted. A new model has been specifically designed to meet the increasing trends towards high pressure working field demand. These models are distinguished by their compact size. All the models use the same components designed by Riello for the RDB series. The high quality level guarantees safe working. In developing these burners, special attention was paid to reducing noise, to the ease of installation and adjustment, to obtaining the smallest size possible to fit into any sort of boiler available on the market. All the models are approved by the EN 67 European Standard and conform to European Directives for EMC, Low Voltage, Machinery and Boiler Efficiency. All the RDB burners are fired before leaving the factory. TS8UK
2 TECHNICAL DATA Model RDB RDBR RDB RDBR RDB. RDB.R RDB. RDB.R RDB RDB. RDB4 Approval Emissions Electrical data Fuel / air data Burner operation mode Modulation ratio at max. output Servomotor Heat output. run time type s kw Mcal/h kg/h Working temperature C min./max. kwh/kg Net calorific value kcal/kg Viscosity mm /s (cst). type Pump delivery Atomised pressure Fuel temperature kg/h bar max. C Fuel pre-heater Fan Air temperature Electrical supply type max. C Ph/Hz/V Auxiliary electrical supply Ph/Hz/V Control box Total electrical power type kw Auxiliary electrical power kw Heaters electrical power Protection level kw IP Pump motor electrical power kw Rated pump motor current A Pump motor start up current A Pump motor protection level IP Fan motor electrical power Rated fan motor current Fan motor start up current Fan motor protection level kw A A IP type Ignition transformer V - V I - I Operation One stage 6,8-6,,6-4,6 4-8,, - 46, ,, -,6-68,7 4 -,7-4,4 -,6 8,6-4,9,6 -,9 8, - 9,7 8-6, 8,4-4,9 8, -,7 8,9-44,6-9,6 -, 48-97,,4 -,,8 -,4 -,,8-9,8 -,,8-4,,8 -,,9-4, -,8, - 4,7-9, /4, (at C) for light oil models /, 6 (at C) for kerosene models R.B.L. (at bar) 8 NO YES NO YES NO YES NO YES NO NO NO centrifugal with forward curve blades 4 // ±% R.B.L. R.B.L.R R.B.L. R.B.L.R R.B.L. R.B.L.R R.B.L. R.B.L.R R.B.L. R.B.L. R.B.L.R SE/LD SE/LD SE/LD SE/LD SE/LD SE/LD SE/LD SE/LD SE/LD SE/LD SE/LD,,7,,7,4,74,4,74,6,6,6,/,,,, 4,9,,7, 4, Incorporated in the control box ( ) - 8 kv ( ) - 6 ma Intermittent (at least one stop every 4 h) Sound pressure Sound power CO emission db (A) W mg/kwh 6 6 6, 6, 6 6 < Grade of smoke indicator N Bacharach < CxHy emission NOx emission mg/kwh mg/kwh < (after the first s) < < 8 < Directive 89/6/EEC, 7//EEC, 98/7/EEC, 9/4/EEC Conforming to EN 67 Certification CE-6 6/ CE-6 6/CE-6 6/ CE-6 6/ CE-6 6/ CE-6 6/ CE-6 6/ CE-6 6/ CE-6 7/99 in progress CE-6 74/99 Reference conditions: Temperature: C Pressure: mbar Altitude: m a.s.l. Noise measured at a distance of meter. Since the Company is constantly engaged in the production improvement, the aesthetic and dimensional features, the technical data, the equipment and the accessories can be changed. This document contains confidential and proprietary information of RIELLO S.p.A. Unless authorised, this information shall not be divulged, nor duplicated in whole or in part.
3 FIRING RATES For every models (e.g. RDB) are available many combustion heads that allows to optimize the working field., RDB RDBR, mm H O hpa (mbar) 4 kg/h 4 6 kw, RDB RDBR, mm H O hpa (mbar) 4 kg/h 4 6 kw 4 4 RDB. RDB.R RDB. RDB.R mm H O hpa (mbar) 4 kg/h 4 6 kw 4 4 RDB. RDB RDB4 mm H O hpa (mbar) kg/h kw Useful working field for choosing the burner Firing rate in progress Test conditions conforming to EN 67: Temperature: C Pressure: mbar Altitude: m a.s.l.
4 FUEL SUPPLY HYDRAULIC CIRCUIT All the models have a Riello geared pump with safety valve on the return circuit, and some are fitted with a fuel pre-heater. The kerosene models have a special kerosene pump, which guarantees reliable operations with this type of fuel. Fuel pump RDB - RDB R T PH U S VR(NO) S Pump with filter and pressure regulator on the delivery pipe VR(NO) Oil return valve normally open Oil input pipe to the nozzle Oil return pipe from the regulator PH Oil pre-heater with thermostat (where provided) U Nozzle 4
5 SELECTING THE FUEL SUPPLY LINES The fuel feed must be completed with the safety devices required by the local regulations in force. The table shows the choice of piping diameter for the various burners, depending on the difference in the height between the burner and the tank and the distance between them. MAXIMUM EQUIVALENT LENGTH OF THE PIPEWORK L[m] Type A system Type B system Pipe size H (m),,,,,, Ø8mm L max (m) 8 6 Ømm L max (m) 9 7 Ø8mm L max (m) Ømm L max (m) A 7 H P H P 6 cm cm H H 6 Type of system that can be installed B P H H Ø P Difference in height Internal pipe diameter Difference in height 4 m Burner Pump Filter Shut-off solenoid valve Suction pipework Bottom valve Return pipework 4
6 VENTILATION The RDB series has been designed and developed paying special attention to reducing noise levels, while guaranteeing high performance of pressure and air delivery, inspite of their compact size. Special attention has also been paid to the air-tightness of the air circuit (this is also checked during the functional tests to the burners on the production line); the air-tightness is guaranteed by special technical solutions and seals, and is always conserved after any servicing operations. All the conventional flue models can be easily converted to balanced flue, and vice versa, by using a special kit. Air suction COMBUSTION HEAD There are several types of available combustion heads, to optimise all the various burner-boiler matchings. A simple adjustment to the combustion head (where fitted) allows adapting secondary air to the burner output. Adjustable combustion head Fixed combustion head Dimensions of the flame D Flame length (m) L max L min D max D min, Flame diameter (m) L Burner output (kw) 4 Example: Burner thermal output = kw; L flame (m) =, m (medium value); D flame (m) =,6 m (medium value) 6
7 ADJUSTMENT BURNER OPERATION MODE All these models are one stage operation; the special profile on the air-damper and its micrometric adjustment, ensure precise working even at the lowest output levels of the burner. One stage operation Output Checked variable C bar ON OFF ON OFF time time Air damper Air damper adjustment START UP CYCLE * Pre-heater Normal TR M Ignition transformer V Lock-out led s ~ s time (s) * only model with pre-heater Correct operation s The burner begins the ignition cycle. s-s Pre-purge with the air damper open. s Ignition. If the pre-heater is fitted there is a further delay before pre-purge; this delay can reach s depending on room and fuel temperatures. Lock-out due to ignition failure If the flame does not light within the safety limit (~s) the burner locks-out. The lock-out is shown by a led on the appliance. 7
8 WIRING DIAGRAMS Electrical connections must be made by qualified and skilled personnel in conformity with the local regulations in force. The terminal board is incorporated in the burner control box and connection is easy following the clear instructions that are given. Appliance fitted with an ignition transformer ONE STAGE OPERATION ~ Hz V L N F TS TL ϑ ϑ S S - Lock out led TL - Regulation thermostat TS - Safety thermostat (manual reset) F - Fuse L N L The following table shows the supply lead sections and types of fuse to be used. Model RDB-R RDB-R RDB.-.R RDB.-.R RDB RDB. RDB4 F L A mm V 6 V 6 V T6 V T6 V T6 V T6 V T6 F = Fuse L = Lead section 8
9 EMISSIONS mg/kwh NO EMISSIONS 8 RDB RDBR RDB RDBR RDB. RDB.R RDB. RDB.R RDB RDB. RDB4 mg/kwh CO EMISSIONS RDB RDBR RDB RDBR RDB. RDB.R RDB. RDB.R RDB RDB. RDB4 db(a) SOUND EMISSIONS (sound pressure) RDB RDBR RDB RDBR RDB. RDB.R RDB. RDB.R RDB RDB. RDB4 The emission data have been measured in the various models at maximum output, in conformity with EN 67 standard. 9
10 OVERALL DIMENSIONS (mm) These models are distinguished by their reduced size, in relation to their output, which means they can be fitted to any boiler on the market. BURNER RDB-R - RDB-R - RDB.-.R - RDB.-.R RDB - RDB. - RDB4 F E A A J J F E H H D I D I L L Model A D H RDB-R RDB-R RDB.-.R RDB.-.R RDB RDB. RDB F , E L I J BURNER-BOILER MOUNTING FLANGE RDB-R - RDB-R RDB.-.R - RDB.-.R 4 4 N O L M P Q 4 4 RDB - RDB. RDB4 N O L M P Q Model L M N O RDB-R RDB-R RDB.-.R RDB.-.R RDB RDB. RDB P Q PACKAGING Model X Y Z kg Z X Y RDB-R RDB-R RDB.-.R RDB.-.R RDB RDB. RDB
11 INSTALLATION DESCRIPTION Skilled and qualified personnel must perform installation, start up and maintenance. A nozzle is fitted to the burner and used for fire tests in the factory. If necessary, change the nozzle on the basis of the maximum output of the boiler. All operations must be carried out as described in the technical handbook supplied with the burner. BURNER SETTING RDB series burners can be adjusted from the back of the burner just using a single tool; the air damper is easily adjustable (thanks to a micrometric screw and a position indicator) without removing the burner cover. Head setting area is easily accessible and the operation is simple thanks to a graduated scale. MAINTENANCE In models RDB and RDB4, the maintenance position is easily carried out by hooking the burner to the flange, after removing it from the fixing screws. Maintenance is easy because all the components, including the combustion head, are easily accessed by just unscrewing a single nut. The main components - the control box, motor and pump - are outside the air circuit, thus avoiding any risk of oil build up inside the circuit. All the electrical components are connected by socketplugs and they are easy to reach for controls.
12 BURNER ACCESSORIES Balanced-conventional flue conversion kit All the RDB series models are easily converted from conventional flue to balanced flue, by replacing the plastic screen on the air intake with the connector for the air supply pipe. The reverse operation can be carried out on all the models from balanced flue to conventional flue burner, by replacing the connector on the air supply pipe with the plastic screen on the air intake. Burner RDB-R - RDB-R RDB.-.R - RDB.-.R RDB - RDB4 Balanced-conventional flue conversion kit Balanced flue kit code Conventional flue kit code Tester The tester controls the correct working of the burner components in the RDB series. It can be fitted to all the models, with or without pre-heater. It is made up of two parts: a control instrument and a "control box" which replaces and simulates the one on the burner. This tester is very simple to use: just replace the burner control box with the tester to check correct working of the motor, valve, pre-heater and flame probe (only photo-resistance). This device has a display showing the levels that have been measured, a selection switch for selecting the component to be tested and four switches to be used in the various working stages of the burner. Burner RDB - RDB R Tester Kit code 876 Direct testing M MOTOR The switch feeds the motor. Measurements V L-N Main voltage ( V) VALVE The switch feeds electromagnetic winding of the coil. A red led signals excitation stage, and a green led signals retainer stage. PRE-HEATER The switch feeds the light oil pre-heater; a green led signals the thermostat cut-in. TRANSFORMER The switch feeds the firing transformer inside the control box and excites the oil valve. A Pre-heater current consumption V M Secondary voltage (low voltage) A Photo-resistance current consumption
13 Light oil filter For cleaning light oil from dirty particles and impurities filters with the following features are available: Burner All models Light oil filter Filtering degree (μm) 6 Kit code 66 Filter made up of aluminium body and stainless steel filtering cartridge; available singularly. Burner Light oil filter Filtering degree (μm) All models 6 Kit code 7 Filter made up of aluminium cover, plastic tank and nylon filtering cartridge; available in packaging of pieces. Light oil filter/degassing unit To solve problems of air or water in the oil circuit a special filter/degassing unit is available, made up of aluminium cover, plastic tank, stainless steel filtering cartridge, air release cap and water purge valve. It is available singularly. Burner All models Light oil filter/degassing unit Filtering degree (μm) Kit code 96 Extended head kit Burner Standard head length (mm) RDB4 Extended head kit Extended head length (mm) 7 Kit code 49
14 SPECIFICATION A special index will help you choose the right burner from the available RDB models. There is also a clear and detailed product specification and description. DESIGNATION OF SERIES Series: RDB Size Possible variations: R Light-oil pre-heater Electrical supply to the system: // /V/Hz RDB R // AVAILABLE BURNER MODEL RDB-R // RDB-R // RDB.-.R // RDB.-.R // RDB // RDB. // RDB4 // 4
15 PRODUCT SPECIFICATION Burner Completely automatic monobloc light oil and kerosene burners, with single-stage operation fitted with: - Fan with forward inclined blades - Air damper with external adjustment, with no need to remove the cover - Air-tight air circuit, also available in the balanced flue version - Single phase electric motor V, Hz - Combustion head fitted with: - stainless steel head cone, resistant to high temperatures - ignition electrodes - flame stability disk - Geared pump (specific version for kerosene) for fuel supply, fitted with filter - pressure regulator - attachments for fitting a pressure gauge and vacuum meter - internal by-pass for preparing for single-pipe installations - Fuel feed solenoid valve incorporated in the pump - Photocell for flame detection - Electronic flame control equipment - Protective filter against radio interference - Light oil nozzle - IP 4 protection level - Fuel pre-heater (optional). Approval: - EN 67 standard - for RDB. -.R in progress. Conforming to: - Directive 89/6/EEC (electromagnetic compatibility) - Directive 7//EEC (low voltage) - Directive 98/7/EEC (machinery) - Directive 9/4/EEC (efficiency). Standard equipment: - Two flexible pipes for connection to the light oil supply line - Two nipples for connection to the pump - Flange, screws and nuts for fixing - Thermal screen - Air intake - Protection grill - Exagonal key - Instruction handbook for installation, use and maintenance - Spare parts list. Available accessories to be ordered separately: - Balanced-conventional flue conversion kit - Tester - Light oil filter - Light oil filter/ degassing unit - Extended head kit (only for RDB4).
16 ISO 9 Cert. n. 6 RIELLO S.p.A. - Via Ing. Pilade Riello, San Pietro di Legnago (VR) Italy Tel Fax Internet: [email protected] Since the Company is constantly engaged in the production improvement, the aesthetic and dimensional features, the technical data, the equipment and the accessories can be changed. This document contains confidential and proprietary information of RIELLO S.p.A. Unless authorised, this information shall not be divulged, nor duplicated in whole or in part.
MODULATING LIGHT OIL BURNERS RL/M SERIES
MODULATING LIGHT OIL BURNERS RL/M SERIES RL 28/M 95/166 332 kw RL 38/M 11/237 45 kw RL 5/M 13/296 593 kw RL 7/M 261/474 143 kw RL 1/M 332/711 1482 kw RL 13/M 498/948 1779 kw RL 19/M 534/1423 2431 kw The
TWO STAGE GAS BURNERS RIELLO 40 GSD SERIES GS10D 29/41 106 kw GS20D 58/81 220 kw
TWO STAGE GAS BURNERS RIELLO 4 GSD SERIES 9/4 6 58/8 The Riello 4 GSD series of two stage gas burners, is a complete range of products developed to respond to any request for home heating. The Riello 4
ONE STAGE GAS BURNERS RIELLO 40 FS SERIES FS3 11 35 kw FS5 23 58 kw FS8 46 93 kw FS10 42 116 kw FS20 81 220 kw
ONE STAGE GAS BURNERS RIELLO FS SERIES FS3 35 kw FS5 3 5 kw FS 93 kw FS kw FS kw The Riello FS series of one stage gas burners, is a complete range of products developed to respond to any request for light
TWO STAGE GAS BURNERS
TWO STAGE GAS BURNERS GAS/2 SERIES GAS 3/2 8/13 3 kw GAS 4/2 12/18 47 kw GAS /2 1/32 66 kw GAS 6/2 3/2 1 kw 4/8 176 kw 1/17 32 kw The GAS/2 series of burners covers a firing range from 8 to 32 kw and they
RL Series. Technical Data Leaflet. Two Stage Light Oil Burners. Light Oil TS0035UK03
Technical Data Leaflet TS0035UK03 Light Oil RL Series Two Stage Light Oil Burners RL 34 MZ 97/154 395 kw RL 44 MZ 155/235 485 kw RL 50 148/296 593 kw RL 64 MZ 200/400 820 kw RL 70 255/474 830 kw RL 100
Oil - kerosene burners
Installation, use and maintenance instructions Oil - kerosene burners One stage operation CODE MODEL TYPE 3747469 G0 474T5 90 (0) - 05/008 TECHNICAL FEATURES Thermal power output 95 3 kw 8 8 kg/h Fuel
LOW NOx DUAL FUEL BURNERS RLS/BP MX SERIES
LOW NOx DUAL FUEL BURNERS RLS/BP MX SERIES RLS 300/BP MX 600/1250 3650 kw RLS 400/BP MX 1000/2000 4500 kw RLS/BP MX series burners are characterised by a modular monoblock structure that means all necessary
Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften D F GB NL Öl-Gebläsebrenner Brûleur fioul Oil burner
Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander
Montage und Bedienungs Anleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften D F GB NL Öl-Gebläsebrenner Brûleur fioul Oil burner
LOW NOX MODULATING DUAL FUEL BURNERS
OW OX MODUATIG DUA FUE BURERS RS/M MX SERIES RS 68/M MX FS1 2/35 86 kw RS 68/M MX FS2 2/35 86 kw RS 12/M MX FS1 3/6 12 kw RS 12/M MX FS2 3/6 12 kw RS 16/M MX FS1 3/93 184 kw The RS/M MX series of burners
Oil, Gas and Dual Fuel Burners
Oil, Gas and Dual Fuel Burners Burner series 130...150 250, 280 Group 3 Capacity 390-3500 kw Table of contents General 1 How to choose a burner 2 Light oil burners Technical data and dimensions 3-4 PI-diagrams
Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL
Öl-Gebläsebrenner Brûleur fioul Light oil burner Stookoliebrander
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL
- mark gas burners Cuenotherm NC.4 - NC.6 - NC.9 14.5-90kW.
- mark gas burners Cuenotherm NC.4 - NC.6 - NC.9 14.5-9kW. Low NO x Comprehensive control panel Gas rack Low NOx combustion head Strong light alloy pressuremoulded housing Electronic ignition transformer
Öl-Gebläsebrenner Brûleur fioul Light oil burner Stookoliebrander
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL
1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;
1/11 CO2 DOSAGE SYSTEMS CO2 dosage system consists of following parts; 1 - O2 trim system with micro processing burner (automatic combustion monitoring), 2 - Other components of O2 trim system, 3 - CO2
OIL BURNERS LOW PRESSURE, DESIGNED FOR COMBUSTION OF LIGHT FUEL OIL, MEDIUM FUEL OIL-1P, WASTE OILS.
LOW PRESSURE OIL BURNERS CBW 50 CBW-150 OIL BURNERS LOW PRESSURE, DESIGNED FOR COMBUSTION OF LIGHT FUEL OIL, MEDIUM FUEL OIL-1P, WASTE OILS. CBW-50 CBW-150 40 100 kw 80 150 kw THIS TECHNICAL DOCUMENTATION
OPERATING AND MAINTENANCE INSTRUCTIONS LIGHT OIL BURNERS
OPERATING AND MAINTENANCE INSTRUCTIONS LIGHT OIL BURNERS ❹ KP-6 ❹ KP-6 L ❹ KP-6 LH ❹ KP-6-2 ❹ KP-6 H-2 OILON OY P.O.Box 5 FIN-15801 LAHTI FINLAND +358-3-85 761 Fax +358-3-857 6239 E-mail [email protected]
Kerosene burners. One stage operation KEROSENE BURNER KEROSENE AND GAS OIL BURNER. Installation, use and maintenance instructions
Installation, use and maintenance instructions Kerosene burners One stage operation KEROSENE BURNER KEROSENE AND GAS OIL BURNER CODE MODEL TYPE 3748360 RDB1 50-90 483T50 3748361 RDB1 70-90 483T50 3748459
Öl-Gebläsebrenner Brûleur fioul domestique Light oil burner Stookoliebrander Quemadores de gasóleo Καυστήρας Πετρελαίου
Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Instrucciones de instalación, uso y mantenimiento Οδηγίες
Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission
Quinta Range Condensing Boilers REMEHA QUINTA RANGE High efficiency wall hung condensing boiler with ultra low NOx emission QUINTA RANGE OUTPUTS Q30: 5.6-28 kw Q45: 7-40 kw Q65: 11-61 kw Q85: 14.4-84.2
Kerosene and Gas oil burner
Installation, use and maintenance instructions Kerosene and Gas oil burner One stage operation CODE MODEL TYPE 20030780 G3B 437T50 (2) - 03/2012 Original instructions Contents 1 Declaration... 3 2 Information
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50
I D F GB E NL 3755116 GS3 551T1 3755117 GS3 551T1
Istruzioni per installazione, uso e manutenzione Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Instrucciones para la instalación, uso y mantenimiento
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
800-292-3279 916 638-0828
800-292-3279 916 638-0828 http://easycleansystems.com/heaters/heater-parts.html VAL6 KBE5S and KBE5L Service manual KBE5S 1 2 Specifications Type VAL6 KBE5S Heat Output 111,000BTU/h Fuel Kerosene, Diesel
MANTA Piston Distributor for Oil and Fluid Grease
MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube
UDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
Condensate water pump with neutralisation system
Pumps for fuel oil and gas boiler Condensate water pump with neutralisation system SK9E/FP8E débit obtenu (l/h) caractéristriques selon la fréquence réglée performances avec une hauteur d aspiration de
820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.
SIT Group 820 NOVA mv MULTIFUNCTIONAL CONTROL FOR GAS THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE PIN 3AP700/2 SINGLE-KNOB MULTIFUNCTIONAL
Weishaupt gas burners type G Gas/oil dual fuel burners types GL and RGL Sizes 1 and 3 1/2000 GB
Weishaupt gas burners type G Gas/oil dual fuel burners types GL and RGL Sizes 1 and 3 1/2000 GB Description Weishaupt G, GL and RGL gas and dual fuel burners satisfy the requirements for operational safety,
United Kingdom en. ErP information. Gas fired condensing boiler Gas 210 ECO PRO
United Kingdom en ErP information Gas fired condensing boiler Gas 210 ECO PRO Dear customer, Thank you for purchasing this appliance. Please read this manual carefully before using the product and keep
Description of functions
Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
Installation, use and maintenance instructions. Gas oil burner. One stage operation CODE MODEL TYPE 3748251 G20S 482T50
Installation, use and maintenance instructions Gas oil burner One stage operation CODE MODEL TYPE 3748251 G20S 482T50 (7) - 01/2011 Contents 1 Declaration... 3 2 Information and general warnings... 4
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
Aludesign K A T A L O G
Aludesign K A T A L O G plynové radiátory DESIGN The result of lengthy experience and technological research, GAZELLE TECHNO today is a universally recognised gas radiator*. It has been completely re-designed
UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)
UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
Electric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
Fossil fuel heating equipment
Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
The Best Selling Domestic Stainless Steel Oil Boiler
The Best Selling Domestic Stainless Steel Oil Boiler Stainless Steel Oil Boiler / Standard Oil Boiler Convenience By using the prograed timer, you can control the HEATING / OFF functions inside your room
CADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
Laddomat 21-60 Charging unit
Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the
UNITOR VACUUM cleaners
UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.
FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES
01D351-GB FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES DOLOMIT FLOAT SWITCHES The DOLOMIT float switches find application in liquid level control in tanks and wells; they require connection
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
DUAL FUEL BURNERS GAS/HEAVY OIL
M A D E I N I TA LY SERIE KN 750/M_1000/M EL DUAL FUEL BURNERS GAS/HEAVY OIL BRUCIATORI MISTI GAS/OLIO COMBUSTIBILE All purpose heating solutions Soluzioni integrate per il riscaldamento All purpose heating
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
Solenoid valves 2/2-way direct-operated Type EV210A
Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral
OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
TOBY DVR5 OIL CONTROL & SAFETY VALVE
TOBY DVR5 OIL CONTROL & SAFETY VALVE TECHNICAL HANDBOOK Principle of Operation The Toby DVR5 Oil Control Valve is a multi function unit for maintaining a constant oil level, regulating the oil flow and
SERVICE SERVICE COMPACT MANUAL. Mod. 3000 92X Mod. 3000 93X Mod. 3000 94X. Part 2
SERVICE COMPACT SERVICE 000 MANUAL Mod. 000 9X Mod. 000 9X Mod. 000 94X Part Forward This Service Handbook is intended to assist with servicing and fault-finding in Caravans and Motor Caravans equipped
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
M A N U A L 13-10-05
Documentation The following information sheets illustrate the description below: 12-WW01-4G-E Sectional view of the lance with main dimensions 12-W101-6G-E Sectional view of the head of the lance with
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Heating with wood chips and pellets
YOUR RELIABLE PARTNER Heating with wood chips and pellets Present on the market 110 for over years 90-150 Advantages of the HERZ firematic boiler User friendly with: Easy operation Automatic cleaning system
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
VDL 53 - Vacuum drying oven for flammable solvents
Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed
Why use Tigerloop in fuel heating systems?
The Original Oil De-aerator Why use Tigerloop in fuel heating systems? Reliability New products are continually being developed in the modern oil heating industry in order to satisfy new laws and regulations
A BIG STEP IN REDUCING YOUR CARBON FOOTPRINT.
A BIG STEP IN REDUCING YOUR CARBON FOOTPRINT. REMEHA CONDENSING BOILER RANGE The most efficient way to reduce your carbon footprint. GAS 210 ECO PRO 2 3 INTRODUCTION BOILER DESCRIPTION BOILER CONSTRUCTION
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB
Compact automatic flow rate regulator with polymer cartridge 127 series REGISTERED BS EN ISO 9001:2000 Cert. n FM 21654 UNI EN ISO 9001:2000 Cert. n 0003 CALEFFI 01166/09 GB Function The AUTOFLOW devices
SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9
CHAPTER TIG welding Introduction pages - & - WELDING POWER SOURCES DC power sources SMARTY 60 POWER page -5 SMARTY 80 / 0 XL page -6 SMARTY TX 50 page -7 AC/DC power sources SMARTY TX 60 Alu page -8 SMARTY
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =
Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
Pressure regulating valve with modulating kit, type DRV
Operation Installation and Maintenance Instructions Pressure regulating valve with modulating kit, type DRV hp-technik GmbH Industriepumpen-Förderaggregate und Anlagenbau Gablonzer Straße 21 D-76185 Karlsruhe
Working towards a cleaner future. 30 to 4000kW. Condensing Aluminium 30 to 600kW. Condensing Stainless Steel 50 to 160kW
Potterton Commercial Commercial Boiler Guide The UK s most comprehensive range of Commercial Boilers 30 to 4000kW Condensing Aluminium 30 to 600kW Condensing Stainless Steel 50 to 160kW Heat Distribution
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
Adjustable room thermostat for heating only or cooling only systems
3 003 Room hermostat RAA30 Adjustable room thermostat for heating only or cooling only systems Room thermostat with manual O/OFF switch wo-position control witching voltage AC 24 250 V Use he RAA30 room
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
TECHNICAL SPECIFICATION TYPE ATESO ALFA
Page: 1 of 5 TECHNICAL SPECIFICATION TYPE ATESO ALFA 1. GENERAL 1.1. Make (trade name of manufacturer): BRANO a.s. 1.2. Type and general commercial description(s): ATESO ALFA 1.2.1 1.2.2. Variants: Versions:
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
www.optimumheat.co.uk
The modern wood pellet boiler with built-in flexibility and remote fingertip control Up to 98% efficient Wide output range Simple touch-panel control Remote control & maintenance Extremly low emissions
Features. Picture. Specifications
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
Natural geothermal energy.
ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
RVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones