4KVA/5KVA Parallel Installation Guide



Similar documents
SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

USER MANUAL Online UPS 6K/10K RACK

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

USER MANUAL Online UPS 1K/2K/3K Rack

Inverter / Charger Installation General Operations and AC and DC Connections

USER MANUAL Online UPS 1K/2K/3K

User Manual 1K/2K/3K Online UPS

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Contractors Guide Central Inverter System Installation

SNMP Web Management. User s Manual For SNMP Web Card/Box

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Anti-blackout system for grid connected solar installations (Solsafe concept)

User Manual WatchPower

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

TMS TANK MANAGEMENT SYSTEM

User s Manual AURORA 1.2K/2.2K

Phase Modular Finally the benefits of Modular ups are for all

How To Use A Power Supply Unit (Upu)

E E V R E - R S - O S L O A L R

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

Configure Inverter output for two utility settings, (1)120V/60Hz, (2)220V/50Hz

User Manual. Modular Online UPS

YSmart Technology Co.,Ltd

Home Solar Kit Owner s Manual. Model: HS

User s Manual. Management Software for Inverter

BB800 Off-Grid Solar System

Axpert MKS-4000/KS-5000 Service manual. Axpert MKS Charger/ Inverter. Service manual

RAY-MAX Integrated Solar Power Strip

HM-W536 Install Guide

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

Installation and operating instructions. Solar charge controller Solarix MPPT Z Z

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

Mobile Data Power Model: MDP-25

Back-UPS Pro 1300/1500 Installation and Operation

SOLAR POWER CONDITIONER Service Manual

Photovoltaic Solar Energy Unit EESFB

Model Number Electrical Compatibility Module Connector Type. M LL-S22 60 cell PV module MC-4 Type 2 Locking

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Quick Start Guide for High Voltage Solar Inverter DC-AC Board EVM. Version 1.3

is then retained absolutely without interruption.

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

PowerGem Pro Uninterruptible Power Supply

PSC-A5 Solar Charge Controller Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

GV- RK1352 Card Reader

2 Installation Explanation

LIFT CONTROL SYSTEMS CATALOGUE 2007

SolarEdge Installation Guide MAN Cover goes here (right-side [odd] page)

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Installation and Operation Guide for PD4000 Series Power Control Center

10000HXL31/15000HXL31/20000HXL31

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Home Solar Kit Owner s Manual. Model: HS

Diesel Generating Set

Phoenix Multi 120Vac 12/1600/70 12/2500/120 24/1600/40 24/3000/70. Phoenix MultiPlus 120Vac 12/2500/120 24/3000/70

500r+ Installation and User Guide

12 Volt 30 Amp Digital Solar Charge Controller

46120-F0 Solar Energy Training System

Online UPS. PowerWalker VFI 1000R/1U

User Manual of Grid Tie Inverter with Limiter

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Installation Instructions for Alarm Module Kit A043F059

User s Manual Before using the inverter, you need to read and save the safety instructions.

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

70-Series CAN Power Management System

Wind Generator. NEMO400 Instruction Manual. Suzhou Shoot Power Equipment Co., Ltd. Serial number:

ACS-30-EU-EMDR-10-MOD

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

GSM HOME SECURITY SYSTEM

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Argus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

MCR1900 Media Converter 19-Slot Chassis

Battery Power Inverters

HP R12000 and R18000 DirectFlow UPS User Guide

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Electric Rotary Actuator - On/Off or programmable control actuator

TruPower-Portable-500W. Solar Starter kit

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Current Transformer (CT) Selection Guide

LIFT CONTROL SYSTEMS CATALOGUE 2007

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

IMPORTANT SAFETY INSTRUCTIONS

GSM Autodialer Professional GJD700 Speech & Text Autodialer

GROWATT NEW ENERGY CO.,LTD. GR - UM

Installation and Operation Back-UPS 1250, 1300, 1500

Transcription:

4KVA/5KVA Parallel Installation Guide 1. Introduction This inverter can be used in parallel with two different operation modes. 1. Parallel operation in single phase with up to 4 units. The supported maximum output power is 16KW/20KVA. 2. Three units work together to support three-phase equipment, one inverter per phase. The supported maximum output power is 12KW/15KVA. NOTE: If this unit is bundled with share current cable and parallel cable, this inverter is default supported parallel operation. You may skip section 3. If not, please purchase parallel kit and install this unit by following instruction from professional technical personnel in local dealer. 2. Package Contents In parallel kit, you will find the following items in the package: Parallel board Parallel communication cable Current sharing cable 3. Parallel board installation This installation steps are only applied to 4K/5K models. Step 1: Remove wire cover by unscrewing all screws. Step 2: Remove communication board by unscrewing two screws as below chart. 1

Step 3: Remove two screws as below chart and remove 2-pin and 14-pin cables. Take out the board under the communication board. Step 4: Remove two screws as below chart to take out cover of parallel communication. Step 5: Install new parallel board with 2 screws tightly. Step 6: Re-connect 2-pin and 14-pin to original position. Parallel board Communication board 2

Step 7: Put communication board back to the unit. Step 8: Put wire cover back to the unit. Now the inverter is providing parallel operation function. 4. Mounting the Unit When installing multiple units, please follow below chart. 500mm 500mm 500mm 500mm 500mm 500mm 500mm NOTE: For proper air circulation to dissipate heat, allow a clearance of approx. 50 cm to the side and approx. 50 cm above and below the unit. Be sure to install each unit in the same level. 5. Battery Connection WARNING! Be sure that all inverters will share the same sets of batteries. Otherwise, the inverters will transfer to fault mode. WARNING: Be sure the length of all battery cables is the same. Otherwise, there will be voltage difference between inverter and battery to cause parallel inverters not working. Follow below chart to connect batteries. All battery cables are connected from inverters to batteries via the same BUS bar. 3

Breaker BUS Bar BUS Bar Recommended battery capacity Inverter parallel numbers 2 3 4 Battery Capacity 400AH 600AH 800AH NOTE: Recommended spec of cable from inverter to BUS bar and breaker is listed as below. The cable used from BUS bar to battery should be X pcs of cable from inverter to BUS bar and breaker. X indicates the number of inverters connected in parallel. Ring terminal: Recommended battery cable and terminal size: Model Typical Amperage Battery capacity 4KVA 67A 200AH 5KVA 84A 200AH Wire Size Cable mm 2 Ring Terminal Dimensions D (mm) L (mm) 1*4AWG 22 6.4 33.2 2*8AWG 14 6.4 29.2 1*4AWG 22 6.4 33.2 2*8AWG 14 6.4 29.2 Torque value 2~ 3 Nm 2~ 3 Nm 4

6. AC Input Connection Parallel in single phase Connect Line wires of AC input from each unit to Line BUS bar. Connect Neutral wires of AC input from each unit to Neutral BUS bar. Refer to below figure for connection of AC input. Breaker Breaker Support three-phase equipment Connect Line wires of the inverter to each phase of the utility. Connect Neutral wires of AC input from each unit to Neutral BUS bar. Refer to below figure for connection of AC input. Breaker 5

WARNING: Only Line wires can be connected breaker. It s not allowed to add breaker into Neutral wires between inverter and the BUS bar. All Neutral wires are connected to the BUS bar directly, and you can add a breaker between the utility and the bus bar in the distributor. WARNING: Be sure the length of all AC input cables is the same to guarantee reliability of sharing current in each unit. WARNING: Recommended spec of cable from inverter to BUS bar and breaker is listed as below. The cable used from BUS bar to AC power should be X pcs of cable from inverter to BUS bar and breaker. X indicates the number of inverters connected in parallel. Suggested cable wire and breaker requirement for AC input connection: Model Amperage for breaker AWG no. Torque 4KVA 40 A 10 AWG 1.4~1.6Nm 5KVA 50 A 8 AWG 1.4~1.6Nm 7. AC Output (Load) Connection Parallel in single phase Connect Line wires of AC output from each unit to Line BUS bar. Connect Neutral wires of AC output from each unit to Neutral BUS bar. Refer to below figure for connection of AC output. Breaker BUS Bar BUS Bar BUS Bar Support three-phase equipment Connect Line wires of AC output from each unit to the load. Connect Neutral wires of AC output from each unit to Neutral BUS bar. Refer to below figure for connection of AC output. 6

Breaker BUS Bar BUS Bar WARNING: Only Line wires can be connected breaker. It s not allowed to add breaker into Neutral wires. All Neutral wires are connected to the BUS bar directly. WARNING: Be sure the length of all AC output cables is the same to guarantee reliability of sharing current in each unit. WARNING: Recommended spec of cable from inverter to BUS bar and breaker is listed as below. The cable used from BUS bar to AC output should be X pcs of cable from inverter to BUS bar and breaker. X indicates the number of inverters connected in parallel. Suggested cable and breaker requirement for AC output connection: Model Amperage for breaker AWG no. Torque 4KVA 40A 10 AWG 1.4~1.6Nm 5KVA 50A 8 AWG 1.4~1.6Nm 8. PV Connection Please refer to user manual of single unit for PV Connection. CAUTION: Each inverter should connect to PV modules separately. 7

9. Parallel Cable Connection Parallel cable includes parallel communication cable and current sharing cable. Please follow below chart to connect to the inverter. 9-1. Parallel Operation in Single phase Two inverters in parallel: Three inverters in parallel: Four inverters in parallel: 9-2. Support 3-phase equipment Follow below chart to connect inverters to support 3-phase equipment. 8

10. LCD Setting and Display Setting Program: Program Description Selectable option Single: 28 AC output mode *This setting is only available when the inverter is in standby mode (Switch off). Parallel: L1 phase: L2 phase: L3 phase: When the units are used in parallel with single phase, please select PAL in program 28. Operation to support three-phase equipment is required to have three inverters. This setting for each unit should be different in L1 phase, L2 phase and L3 phase separately. Please set up this setting corresponding to each phase connection. Besides, power saving function will be automatically disabled. 30 PV judge condition (Only apply for setting Solar first in program 1: Output source priority) One Inverter (Default): All of Inverters: When ONE is selected, as long as one of inverters has been connected to PV modules and PV input is normal, parallel or 3-phase system will continue working according to rule of solar first setting. For example, two units are connected in parallel and set SOL in output source priority. If one of two units has connected to PV modules and PV input is normal, the parallel system will provide power to loads from solar or battery power. If both of them are not sufficient, the system will provide power to loads from utility. When ALL is selected, parallel or 3-phase system will continue working according to rule of solar first setting only when all of inverters are connected to PV modules. For example, two units are connected in parallel and set SOL in output source priority. When selecting ALL in program 30, it s necessary to have all inverters connected to PV modules and PV input is normal to allow the system to provide power to loads from solar and battery power. Otherwise, the system will provide power to loads from utility. 9

Fault code display: Fault Code Fault Event Icon on 60 Power feedback protection 71 Firmware version inconsistent 72 Current sharing fault 80 CAN fault 81 Host loss 82 Synchronization loss 83 Battery voltage detected different 84 AC input voltage and frequency detected different 85 AC output current unbalance 86 AC output mode setting is different 11. Commissioning Parallel in single phase Step 1: Check the following requirements before commissioning: Correct wire connection Ensure all breakers in Line wires of load side are open and each Neutral wires of each unit are connected together. Step 2: Switch on DC breakers of each unit. Step 3: Turn on each unit. LCD display in Master unit LCD display in Slave unit 10

NOTE: Master and slave units are randomly defined. Step 4: Switch on all AC breakers of Line wires in AC input. It s better to have all inverters connect to utility at the same time. If not, it will display fault 82 in following-order inverters. However, these inverters will automatically restart. If detecting AC connection, they will work normally. LCD display in Master unit LCD display in Slave unit Step 5: If there is no more fault alarm, the parallel system is completely installed. Step 6: Please switch on all breakers of Line wires in load side. This system will start to provide power to the load. Support three-phase equipment Step 1: Check the following requirements before commissioning: Correct wire connection Ensure all breakers in Line wires of load side are open and each Neutral wires of each unit are connected together. Step 2: Switch on DC breakers of three units. Step 3: Turn on three units. LCD display in L1-phase unit LCD display in L2-phase unit LCD display in L3-phase unit Step 4: Switch on all AC breakers of Line wires in AC input. If AC connection is detected and three phases are matched with unit setting, they will work normally. Otherwise, the AC icon will flash and they will not work in line mode. LCD display in L1-phase unit LCD display in L2-phase unit LCD display in L3-phase unit 11

Step 5: If there is no more fault alarm, the system to support 3-phase equipment is completely installed. Step 6: Please switch on all breakers of Line wires in load side. This system will start to provide power to the load. Note 1: To avoid overload occurring, before turning on breakers in load side, it s better to have whole system in operation first. Note 2: Transfer time for this operation exists. Power interruption may happen to critical devices, which cannot bear transfer time. 12. Trouble shooting Fault Code Situation Fault Event Description Solution 60 Current feedback into the inverter is 1. Restart the inverter. detected. 71 1. Update all inverter firmware to the same The firmware version of each inverter version. is not the same. 72 1. Check if sharing cables are connected well and The output current of each inverter is restart the inverter. different. 80 CAN data loss 1. Check if communication cables are connected 81 Host data loss 82 Synchronization data loss 83 84 The battery voltage of each inverter is not the same. AC input voltage and frequency are detected different 85 AC output current unbalance 86 AC output mode setting is different. well and restart the inverter. 1. Make sure all inverters share same groups of batteries together. 1. Check the utility wiring conncetion and restart the inverter. 1. Restart the inverter. 1. Switch off the inverter and check LCD setting #28. 12