Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact



Similar documents
Three-phase monitoring relay CM-PFE

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Analog signal converters CC-E I/I Current / current isolators

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF19 and EF45

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

38 Series - Relay interface modules A

Thermistor motor protection

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

38 Series - Relay interface modules A

Grid feeding monitoring according to VDE-AR-N 4105 and BDEW CM-UFD.M31

MasterINTERFACE 39 Series - Relay interface modules

Type: DILM32 10(24V50HZ) Article No.:

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Manual motor starter MS116

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

MasterINTERFACE 39 Series - Relay interface modules

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Pluggable interface relays CR-P Pcb relays

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Relés e Contatores de Estado Sólido SIRIUS

RM4TG20 three-phase network control relay RM4-T - range V

Catalog. Modular DIN rail components Installation contactors

Three-phase monitoring relays Product group picture

Type: DILM9 10(24VDC) Article No.:

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

48 SERIES Relay interface modules 10 A

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

80 Series - Modular timers 16 A. Features

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

15 Series - Electronic step relay and dimmer. Features SERIE

EMR measuring and monitoring relays

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Redundancy Module QUINT-DIODE/40

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

49 Series - Relay interface modules A. Features

Safety technique. Emergency stop module BO 5988 safemaster

PHOENIX CONTACT Features

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

80 Series - Modular timers 16 A. Features

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Technical catalogue. Modular DIN rail components Installation contactors

E-STOP relays, safety gate monitors

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

ZS25 Screw Clamp Terminal Blocks Feed-through

STRATO LED Drivers 70W, Single output

R.C.C.B. s two-pole LEXIC

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Technicaldata General

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Signal converters Index

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Telephone- and leased line modem for industrial applications TD-36

Waveguide Access Point WGA631. Product Guide

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Bimetallic Overload Relay Specifications

40 Series - Miniature PCB/Plug-in relays A. Features

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Power Supplies 3. SDN-P DIN Rail Series

RY2 miniature industrial relays

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Safety automation solutions

Quick Connect. quick - simple - efficient.

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

7 - Phaseo power supplies and transformers

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Digital input modules

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Signal converters Index

Transcription:

Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only 17.5 mm, the CT-D range timers are ideally suited for installation in distribution panels as well as for industrial applications where compact dimensions are required. 2CDC 251 094 F0006 Characteristics Rated control supply voltage 24 48 V DC, 24 240 V AC Single function timer OFF delay 7 time ranges (0.05 s 100 h) in one device Control input: voltage related triggering, polarized, capable of switching a parallel load Light grey enclosure in RAL 7035 1 c/o (SPDT) contact (250 V / 6 A) Width of only 17.5 mm (0.689 in) 2 LEDs for the indication of operational states Approvals A UL 508, CAN/CSA C22.2 No.14 R K E L Marks a b EAC CB scheme CCC RMRS CE RCM Order data Type Rated control supply voltage Time range Output Order code CT-AHD.12 24 48 V DC, 24 240 V AC 0.05 s 100 h 1 c/o (SPDT) contact 1SVR 500 110 R0000

Functions Operating controls 1 Rotary switch for the preselection of the time range 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Indication of operational states U: green LED V control supply voltage applied W timing R: yellow LED V output relay energized 4 4 Circuit diagram 2CDC 251 094 F0006 1 3 2 Application With their structural form and their width of only 17.5 mm, the CT D range timers are ideally suited for installation in distribution panels. Operating mode The CT AHD.12 with 1 c/o (SPDT) contact and offers 7 time ranges, from 0.05 s to 100 h. The time delay range is rotary switch selectable on the front of the unit. The fine adjustment of the time delay is made via an internal potentiometer, with a direct reading scale, on the front of the unit. 2 - Electronic timer CT-AHD.12 Data sheet

Function descriptions / diagrams B OFF delay with auxiliary voltage This function requires continuous control supply voltage for timing. If control input A1 Y1/B1 is closed, the output relay energizes immediately. If control input A1 Y1/B1 is opened, the time delay starts. The green LED flashes during timing. When the selected time delay is complete, the output relay de energizes and the flashing green LED turns steady. If control input A1 Y1/B1 recloses before the time delay is complete, the time delay is reset and the output relay does not change state. Timing starts again when control input A1 Y1/B1 re opens. If control supply voltage is interrupted, the output relay de energizes and the time delay is reset. A1-A2 A1-Y1/B1 15-18 15-16 green LED t = adjusted time delay t < t 2CDC 252 036 F0207 Electrical connection A1 Y1/ B1 A1 15 15 Y1/B1 A1 A2 Rated control supply voltage U s 24 48 V DC or 24 240 V AC A1 Y1/B1 Control input 15-16/18 1 c/o (SPDT) contact 18 A2 16 16 18 A2 2CDC 252 117 F0b06 Connection diagram Wiring instructions Parallel load to control input possible / allowed L(+) A1 Y1/B1 N(-) A2 2CDC 252 102 F0b06 Data sheet Electronic timer CT-AHD.12-3

Technical data Data at T a = 25 C and rated values, unless otherwise indicated Input circuits Supply circuit A1-A2 Rated control supply voltage U s 24 240 V AC, 24 48 V DC Rated control supply voltage U s tolerance -15...+10 % Typical current / power consumption 24 V DC 14 ma / 0.3 W 115 V AC 52 ma / 1.3 VA 230 V AC 60 ma / 2.4 VA Rated frequency DC; 50/60 Hz Frequency range AC 47 63 Hz Power failure buffering time min. 20 ms Release voltage > 10 % of the min. rated control supply voltage U s Control circuit Control input, control function A1 Y1/B1 start timing external Kind of triggering voltage related triggering Resistance to reverse polarity yes Polarized yes Capable of switching a parallel load yes Maximum cable length to the control inputs 50 m 100 pf/m Minimum control pulse length 20 ms Control voltage potential see rated control supply voltage U s Current /power consumption of the control 24 V DC 3.8 ma / 0.1 W input 115 V AC 23.9 ma / 0.4 VA 230 V AC 26.9 ma / 0.7 VA Timing circuit Kind of timer Single function timer OFF delay with auxiliary voltage Time ranges 0.05 s 100 h 0.05 1 s, 0.5 10 s, 5 100 s, 0.5 10 min, 5 100 min, 0.5 10 h, 5 100 h Recovery time < 50 ms Repeat accuracy (constant parameters) Dt < ± 0.5 % Accuracy within the rated control supply voltage tolerance Dt < 0.005 % / V Accuracy within the temperature range Dt < 0.06 % / C Setting accuracy of time delay (IEC/EN 61812-1) ± 10 % of full-scale value User interface Indication of operational states Control supply voltage / timing U: green LED V: control supply voltage applied W: timing Relay status R: yellow LED V: output relay energized 4 - Electronic timer CT-AHD.12 Data sheet

Output circuit Kind of output 15-16/18 relay, 1 c/o (SPDT) contact Contact material Cd free Rated operational voltage U e (IEC/EN 60947-1) 250 V Minimum switching voltage / Minimum switching current 12 V / 100 ma Maximum switching voltage / Minimum switching current see load limit curve / see load limit curve Rated operational current I e AC12 (resistive) at 230 V 6 A (IEC/EN 60947-5-1) AC15 (inductive) at 230 V 3 A DC12 (resistive) at 24 V 6 A DC13 (inductive) at 24 V 2 A AC rating (UL 508) utilization category (Control Circuit Rating Code) B 300 max. rated operational voltage 300 V AC maximum continuous thermal current at B 300 5 A max. making/breaking apparent power at B 300 3600 VA / 360 VA Mechanical lifetime 30 x 10 6 switching cycles Electrical lifetime AC12, 230 V, 4 A 0.1 x 10 6 switching cycles Maximum fuse rating to achieve n/c contact 6 A fast-acting short-circuit protection (IEC/EN 60947 5 1) n/o contact 10 A fast-acting General data MTBF on request Duty time 100 % Dimensions (W x H x D) product dimensions 17.5 x 70 x 58 mm (0.69 x 2.76 x 2.28 in) packaging dimensions 89 x 65 x 20 mm (3.50 x 2.56 x 0.79 in) Weight net weight 0.053 kg (0.117 lb) gross weight 0.065 kg (0.143 lb) Mounting DIN rail (IEC/EN 60715), snap on mounting without any tool Mounting position any Minimum distance to other units, horizontal not necessary normal operation mode vertical not necessary Degree of protection housing IP50 terminals IP20 Electrical connection Wire size fine-strand with wire end ferrule 2 x 0.5 1.5 mm 2 / 1 x 0.5 2.5 mm 2 (2 x 20 16 AWG / 1 x 20 14 AWG) Stripping length Tightening torque fine-strand without wire end ferrule rigid 2 x 0.5 1.5 mm 2 / 1 x 0.5 2.5 mm 2 (2 x 20 16 AWG / 1 x 20 14 AWG) 2 x 0.5 1.5 mm 2 / 1 x 0.5 4 mm 2 (2 x 20 16 AWG / 1 x 20 12 AWG) 7 mm (0.28 in) 0.5 0.8 Nm (4.43-7.08 lb.in) Environmental data Ambient temperature ranges operation -20...+60 C storage -40...+85 C Climatic class (IEC/EN 60068 2 30) 3k3 Relative humidity range 25 % to 85 % Vibration, sinusoidal (IEC/EN 60068 2 6) 20 m/s 2, 10 cycles, 10...150...10 Hz Shock, half sine (IEC/EN 60068 2 27) 150 m/s 2, 11 ms Data sheet Electronic timer CT-AHD.12-5

Isolation data Rated insulation voltage U i output circuit 1 / output circuit 2 n.a. input circuit / output circuit 300 V Rated impulse withstand voltage U imp between all isolated circuits (IEC/EN 60664-1) 4 kv; 1.2/50 μs (type test) Power frequency withstand voltage between all isolated circuits (test voltage) 2.5 kv, 50 Hz, 1 s (routine test) 2.5 kv, 50 Hz, 60 s (type test) Basic insulation (IEC/EN 61140) input circuit / output circuit 300 V Protective separation input circuit / output circuit (IEC/EN 61140, EN 50178) 250 V Pollution degree (IEC/EN 60664 1) 3 Overvoltage category (IEC/EN 60664 1) III Standards Product standard IEC/EN 61812 1 Low Voltage Directive 2006/95/EC EMC directive 2004/108/EC RoHS Directive 2011/65/EC Electromagnetic compatibility Interference immunity to IEC/EN 61000 6 1 IEC/EN 61000 6 2 electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kv / 8 kv) radiated, radio-frequency, IEC/EN 61000-4-3 Level 3 (10 V/m) electromagnetic field electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kv / 5 khz) surge IEC/EN 61000-4-5 Level 3 (2 kv L-L) conducted disturbances, induced by IEC/EN 61000-4-6 Level 3 (10 V) radio-frequency fields Interference emission IEC/EN 61000-6-3, IEC/EN 61000-6-4 high-frequency radiated IEC/CISPR 22, Class B EN 55022 high-frequency conducted IEC/CISPR 22, EN 55022 Class B 6 - Electronic timer CT-AHD.12 Data sheet

Technical diagrams Load limit curves AC voltage [V] DC voltage [V] resistive load resistive load AC current [A] 2CDC 252 044 F0207 DC current [A] 2CDC 252 045 F0207 AC load (resistive) DC load (resistive) Derating factor F 1.0 0.9 0.8 Switching cycles 0.7 0.6 250 V resistive load 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ 2CDC 252 124 F0206 Switching current [A] 2CDC 252 123 F0206 Derating factor F for inductive AC load Contact lifetime Data sheet Electronic timer CT-AHD.12-7

Dimensions in mm and inches 0.69 17,5 0.2 5 58 2.28 43,4 1.71 2CDC 252 131 F0b06 70 2.76 45 1.77 Further documentation Document title Document type Document number Electronic products and relays Technical catalogue 2CDC 110 004 C02xx CT-D range Instruction manual 1SVC 500 010 M1000 You can find the documentation on the internet at www.abb.com/lowvoltage -> Control Products -> Electronic Relays and Controls -> Time Relays. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com/portal/portal/abb-control-products -> Low Voltage Products & Systems -> Control Products -> Electronic Relays and Controls -> Time Relays -> CT-D - Time Relays. 8 - Electronic timer CT-AHD.12 Data sheet

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 111 161 D0201 (02.2015) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2015 ABB All rights reserved