AMDx4 INTERFACE CONTROL PANEL FOR AUTOMATIC SOFTENERS AM/D METER INSTRUCTIONS MANUAL INSTRUCTIONS FOR INSTALLATION OPERATION & MAINTENANCE WARNING! The equipment must be used only for the utilization for which they have been designed, as shown in the technical documentation. Read carefully this leaflet until the end before starting any operation. Proceed strictly according to all directions included in this manual. ANY OTHER APPLICATIONS OF THE EQUIPMENT DIFFERENT THAN THE MENTIONED ONES IS MADE UNDER THE ONLY RESPONSIBILITY OF THE USER. For any assistance concerning the installations, maintenance or utilization of the equipment apply the NOBEL Service Center closest to you or directly : NOBEL S.r.l. e-mail: nobel@nobelitaly.it tel. +39 02 2827968 fax +39 02 2610839 rel. 0 Page 1 of 3 amdx4_mi-r0.doc
INSTRUCTIONS MANUAL AMDx4 1. Norme di sicurezza 1.1. CE mark, declaration of conformity The equipment is designed to meet state-of-the-art safety requirements, has been tested and left the factory in a condition in which it is safe to operate. The equipment complies with the applicable standards and regulations as listed in the CE declaration of conformity and thus complies with the statutory requirements of the CE Directives. NOBEL confirms the successful testing of the equipment by sticking to it the CE mark. 1.2. Elettricità Before starting any operation on electrical devices, be sure that main power supply is OFF. All operations must be performed by skilled and authorized operators, using proper tools and personal protection devices if required (CE marked), according to safety regulations for working areas. In case of liquid leakage, switch off the main power supply before operation. Before the switching ON, be sure all the parts of the system are perfectly dry. Check that the available electrical power is correct, as shown on technical data Do not make preliminary wiring connections. 2. Technical characteristics 2.1. Caratteristiche generali max ambient temperature C 40 power supply V ph/hz W 110 240 1/50 60 20 weight (approx) kg 3 dimensions mm 300 x 260 x 150 (p) 2.2. Placing and electrical wiring connections Fix the control board to the wall near the softener columns. Make wiring connections in the control board according to the annex wiring diagram); the power supply is connected directly to the input terminals of the general s.r.l. - ITALY Page 2 of 3 amdx4_mi-r0.doc - r.0
INSTRUCTIONS MANUAL AMDx4 3. Principles of working The interface panel AMDx4 allows to connect the automatic controls of 4 softeners series AM/D Meter, in order that they can work on parallel, featuring the regeneration in succession, one after the other one. Hence, 3 softeners are on service while the fourth one is on regeneration or stand-by. Whether only 3 softeners are installed, it is required to make a bridge connection between the clamp +R and the input I8. According to that, 2 softeners will be on service while the third one is on regeneration or stand-by. The system does not allow to run automatically more than one regeneration in the same time. 4. Programmer The logical programmer handles the logical working of the whole unit. Its does not require configuration; if desired it is possible to set the current time and day The programmer is equipped with internal clock, keeping exact time for 80 hours in case of power failure. To set the current time and day, proceed as follows : 1. push the button ESC 2. push the button until the pointer > indicates "Set " 3. push the button OK 4. the pointer indicates Clock.., push the button OK 5. the pointer indicates Set Clock.., push the button OK 6. push the button to point the day or the number to be modified 7. when the pointer blinks on the day or the number to be modified, push the button or until the new desired day or value is shown (symbols related to days of week are explained at following chapter) 8. repeat the same operation with other values, if required 9. push the button OK to confirm (save) the modifications 10.push twice the button ESC to go back to the visualization of service. The programmer is already factory set for automatic updating with european summer time (S/W Time ON = EU) s.r.l. - ITALY Page 3 of 3 amdx4_mi-r0.doc - r.0
s.r.l. via G.Galilei, 5 20090 Segrate (MI) - ITALY AZIENDA CON SISTEMA QUALITÁ CERTIFICATO DA DNV UNI EN ISO 9001/2008 TEL. +39 02 2827968 FAX +39 02 2610839 e-mail nobel@nobelitaly.it www.nobelitaly.it società italiana per lo studio e la realizzazione di apparecchiature ed impianti per il trattamento acqua engineering and manufacturing of equipments and plants for water treatment DICHIARAZIONE DI CONFORMITÀ DECLARATION OF CONFORMITY La Nobel srl dichiara che l apparecchiatura (vedi etichetta in prima pagina) delle serie Nobel srl hereby declares that the equipment (see label on first page) of series AMDx4 è conforme alle seguenti Direttive Europee: 2006/42/CE 2006/95/CE 2004/108/CE Principali Norme armonizzate osservate durante la progettazione e costruzione: UNI EN ISO 12100:2010 UNI EN 60204-1 (CEI 44-5) Il direttore tecnico è autorizzato alla costituzione del fascicolo tecnico. complies to the requirement of the following European Directives : 2006/42/CE 2006/95/CE 2004/108/CE Besides, the main regulations followed for the design and manufacturing are : UNI EN ISO 12100:2010 UNI EN 60204-1 (CEI 44-5) The technical manager is authorized to manage the technical folder. Direttore Tecnico Technical Manager Giorgio Da Dalt Milano, 4 maggio 2012 M3.6-r2 sede legale : via Monfalcone 8 20132 Milano C.C.I.A.A. 1250687 - EXPORT MI 044905 - Reg. Trib. Milano nº 272528 vol.7032 fasc.28 società a responsabilità limitata - cap. soc. 99.000 i.v. - C.F. e P.I. : IT 08829620155 rev. 0