Performance of the BaF2-calorimeter TAPS 1



Similar documents
The accurate calibration of all detectors is crucial for the subsequent data

Information about the T9 beam line and experimental facilities

Calorimetry in particle physics experiments

Single photon detection with H8500 MAPMTs for the CBM RICH detector*

MICE detectors and first results. M. Bonesini Sezione INFN Milano Bicocca

Neutron Detection Setups proposed for

Gamma Ray Detection at RIA

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

07 - Cherenkov and transition radiation detectors

High Energy Physics. Lecture 4 More kinematics and a picture show of particle collisions

EXPERIMENTAL CONDITIONS FOR CROSS SECTION MEASUREMENTS FOR ANALYTICAL PURPOSES. L. Csedreki 1. Abstract. I. Introduction

Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission

The AGATA campaign at GSI. Zsolt Podolyák University of Surrey

Event viewer for HRS-L

POSSIBL-E EXPERIMENTS ON THE 200-GeV ACCELERATOR. A. D. Krisch University of Michigan. R. Serber Columbia University.

Top rediscovery at ATLAS and CMS

Atomic and Nuclear Physics Laboratory (Physics 4780)

Recent developments in Electromagnetic Hadron Form Factors

The OPERA Emulsions. Jan Lenkeit. Hamburg Student Seminar, 12 June Institut für Experimentalphysik Forschungsgruppe Neutrinophysik

arxiv:nucl-ex/ v2 18 Jul 2005

Cross section, Flux, Luminosity, Scattering Rates

IMPROVEMENT OF JET ENERGY RESOLUTION FOR SEGMENTED HCAL USING LAYER WEIGHTING TECHNIQUE

Proton tracking for medical imaging and dosimetry

The data acquisition system of the XMASS experiment

THE DØ Luminosity Monitor (LM) consists of two array of

PoS(PhotoDet 2012)068

A Guide to Detectors Particle Physics Masterclass. M. van Dijk

Status and perspective of emission imaging techniques for ion beam therapy in Lyon

Tutorial 4.6 Gamma Spectrum Analysis

Evaluation Tools for the Performance of a NESTOR Test Detector

ATLAS Test Beam Analysis in Stockholm: An Overview

Vacuum Evaporation Recap

Energy Deposition in MICE Absorbers and Coils

An option for the SHiP Muon Detector: Scintillator bars with WLS fibers and SiPMs readout

Cathode Ray Tube. Introduction. Functional principle

Radiation Detection and Measurement

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

Performance Comparison of Four Commercial GE Discovery PET/CT Scanners: A Monte Carlo Study Using GATE

arxiv:astro-ph/ v1 15 Sep 2005

Hadro-Production Experiments: Impact on T2K and LBNE

Track Trigger and Modules For the HLT

Testing thermo-acoustic sound generation in water with proton and laser beams

Modification of Pd-H 2 and Pd-D 2 thin films processed by He-Ne laser

ACCELERATORS AND MEDICAL PHYSICS 2

Characteristics of an Integrated Germanium Detector Based Gamma-Ray Spectrometer for Monitoring Systems

Masses in Atomic Units

TOF FUNDAMENTALS TUTORIAL

Development of on line monitor detectors used for clinical routine in proton and ion therapy

ISTITUTO NAZIONALE DI FISICA NUCLEARE

CHAPTER 7 SCINTILLATION COUNTING

NANOFLAM. Projet ANR Blanc 2011 BS Aide allouée: , durée 36+8 mois (fin : Mai 2015) Laboratoire H. Curien

Measurement of Muon Lifetime and Mass Using Cosmic Ray Showers

Operation and Performance of the CMS Silicon Tracker

ASACUSA: Measuring the Antiproton Mass and Magnetic Moment

Study of the B D* ℓ ν with the Partial Reconstruction Technique

Experimental results for the focal waveform and beam width in the focusing lens with a 100 ps filter

AGATA The Advanced Gamma Ray Tracking Array

Nuclear Physics and Radioactivity

Tracking systems in HEP:

Secondary Ion Mass Spectrometry

TOF-PET DETECTOR CONCEPT BASED ON ORGANIC SCINTILLATORS

Jet Reconstruction in CMS using Charged Tracks only

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Medical Applications of radiation physics. Riccardo Faccini Universita di Roma La Sapienza

Gamma Rays OBJECT: READINGS: APPARATUS: BACKGROUND:

Discovery of neutrino oscillations

90 degrees Bremsstrahlung Source Term Produced in Thick Targets by 50 MeV to 10 GeV Electrons

The Mainz LXe TPC MC simulations for a Compton scattering experiment

Encoders for Linear Motors in the Electronics Industry

Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope

bulk 5. Surface Analysis Why surface Analysis? Introduction Methods: XPS, AES, RBS

Neutron Resonance Spectroscopy for the Characterisation of Materials and Objects

ORTEC. Fast-Timing Discriminator Introduction. Choosing the Right Timing Discriminator for the Application. Counting

Modification of Graphene Films by Laser-Generated High Energy Particles

ENERGY LOSS OF ALPHA PARTICLES IN GASES

An Innovative Method for Dead Time Correction in Nuclear Spectroscopy

Scanning Near-Field Optical Microscopy for Measuring Materials Properties at the Nanoscale

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

Top-Quark Studies at CMS

2 Absorbing Solar Energy

A wave lab inside a coaxial cable

PROSPECT: Precision Reactor Oscillation and Spectrum experiment

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

A VERSATILE COUNTER FOR CONVERSION MÖSSBAUER SPECTROSCOPY

How To Use An Ionsonic Microscope

CMS Tracking Performance Results from early LHC Running

Cyclotron Centre in Poland and 2D thermoluminescence dosimetry

dissociation: projectile charge and Furthermore we have observed that with increasing impact energy the kinetic energy of the fragments

How To Improve The Ganil Control System

Transcription:

ELSEVIER Nuclear Physics B (Proc. Suppl.) 61B (1998) 137-142 UCLEAR PHYSIC~ PROCEEDINGS SUPPLEMENTS Performance of the BaF2-calorimeter TAPS 1 R.Novotny II. Physics Institute, University Giessen, Heinrich-Buff-Ring 16, D-35392 Giessen, Germany The electromagnetic calorimeter TAPS (Two/Three Arm Photon Spectrometer) - comprising in its present set-up 384 individual plastic-baf2 scintillator telescopes - has been constructed to identify and measure hard photons and neutral mesons via the reconstruction of tlhe invariant mass from their two or three photon decay modes. Photons can be detected up to an energy of 15 GeV with high resolution (~/E = 2.5% at 1 GeV). Neutrons and charged particles are identified by pulse-shape analysis (PSA) and time-of-flight techniques (TOF) with high efficiency. The optional modification into modular plastic/baf2 phoswich telescopes allows improved particle spectroscopy at medium energies simultaneously. 1. PHYSICS MOTIVATION The calorimeter TAPS [1] was planned and built by an European collaboration [2] to investigate high energy photons as well as neutral mesons (~o, ~, e0) in relativistic and ultra-relativistic heavy ion collisions or photonuclear reactions, respectively. The point of impact and the total energy of the electromagnetic shower (E.M.) have to be determined precisely to reconstruct the invariant mass from the meson decays into two or three photons. The high multiplicity of hadronic reaction products requires a very efficient discrimination against charged or neutral particles as well. BaF2 is the most appropriate scintillator material due to its high light output, fast response and intrinsic selectivity of its pulse-shape to the nature of the impinging probe [3]. The envisaged very broad range of the diversified and rich research program at different accelerator facilities in Europe (AGOR, CERN-SPS, GANIL, GSI, MAMI) requires the modularity of the device and high flexibility in the geometrical arrangement of the experimental setup. 2. THE DETECTOR CONCEPT 2.1. The individual detector 250 Figure 1. The geometry of the individual plastic- and BaF2-scintillator. The dimensions are given in mm. Each of the almost 400 detector components consists of a 250 mm long (12Xo) hexagonally shaped BaF2-crystal (inscribed circle O = 59 mm) [4]. The last 25 mm are 1 supported by BMBF, DFG and GSI 0920-5632/98/$19.00 1998 Elsevier Science B.V. All rights reserved. PI1 S0920-5632(97)00552-5

138 R. Novotny/Nuclear Physics B (Proc. Suppl.) 6IB (1998) 137 142 machined cylindrically in diameter (0 = 52 mm) to allow optimum magnetic shielding (see Figure 1). Laser light can be fed into each crystal by a quartzfibre for gain monitoring and calibration of the read-out electronics. The crystals are wrapped with PTFE and an additional layer of aluminum foil as UV-reflector and coupled optically to the quartz window of the photomultiplier tube (Hamamatsu R2059-01) with high viscosity grease. The assembly of the individual module including the base is achieved using 0.2 mm thick heat shrinkable PVC-tubing [1], which is light tight and provides the sufficient mechanical strength. only in case of the standard block geometry of 8 by 8 modules as illustrated in Figure 2. 6 Blocks with Beamline / 64 M / i' ~ at'ray of 32 PMT's ~%4 TAPS -'- BaF2 - modules f ~ ~ / ~ ~ ~rray of 32 PMT'a bl~102a scintillator perspex lightguido Figure 2. The fully assembled detector block consisting of 64 plastic-baf2 scintillator telescopes. The modular detectors can be grouped in blocks (see Figure 2) arranged either on top of each other in two/three movable towers or in a ring in the horizontal plane through the target as shown in Figure 3. Alternatively, a large annular hexagonal supercluster can be formed. A charged particle veto (CPV) consisting of hexagonal plastic scintillators (5mm NE102A) read-out individually by lightguides and photomultipliers can be mounted in front / / ~ / Forward Wall with / ~ 120 Phoswich Modules Figure 3. The TAPS set-up as used at the tagged photon facility of MAMI at Mainz. The optical transmission, signal shape, energy response of the fast and slow scintillation component to low energy T- sources and the contamination of a-emitting radionuclei (identified via the analysis of the pulse-shape) are measured carefully for each crystal. Table i shows the obtained test results averaged over 450 accepted crystals (in collaboration with A2 at Mainz) in comparison to the required specification limits. Crystals of a total length of 350 mm (quadratic diameter 35x35mm2), recently manufactured by SICCAS (Shanghai, China), have been investigated in an identical manner and the results are shown for comparison. The processing of the BaF2-signals foresees the determination of the time-ofimpact (TOF-analysis) and the integration of the total as well as the fast scintillation component separately (integration gates 2~s and 40ns, respectively) to perform pulseshape analysis of the E.M. shower.

R. Novotny/Nuclear Physics B (Proc. Suppl.) 61B (1998) 137 142 139 Table 1: Test results obtained for 450 accepted TAPS crystals compared to the required s2ecifications and to recently produced samples of different ~eome ry (see text for details). performance parameter TAPS CHINA CHINA spec.limits absorption length A [em] 137Cs: E T = 662 kev average average best results at ~ = 200 nm 41.7 22.8 27.5 18.0 at ~ = 220 nm 76.7 41.8 56.6 28.0 at ~ = 300 nm 488.7 139.2 188.6 292.0 fast: AE/E [% FWHM] 35.3 45.7 40.2 45.0 total: AE/E [% FWHM] 11.5 14.0 11.5 12.5 intensity ratio fast/slow at At=40ns 9.5 9.4 12.0 7.0 e Co: ET- 1.33 MeV a-activity peak/valley ratio 2.28 1.61 2.30 2.00 dn/dt [counts s 1 cm -3] 0.021 0.175 0.071 0.133 2.2. Particle/Photon Identification The identification and discrimination of neutral and charged particles can be achieved exploiting the intrinsic properties of BaF2 in combination with a fast plastic scintillator used either as a separate CPV system or as a phoswich detector when coupled optically to the BaF2-crystal. The short decay time and the high light output of BaF2 allow time resolutions better than g=85 ps even for the large TAPS modules [5]. Therefore, particle identification and even energy determination can be performed based on TOF-technique at a typical distance of 1-2 m from the vertex using a start-counter system as time reference. In particular, low and medium energy neutrons, which react via (n,7)- processes with BaF2 and induce a signalshape identical to that of photons, can only be identified via TOF. Restricted to the standard TAPS block geometry, the CPV system allows as well an online tagging of charged or neutral hits as the measurement of the specific energy loss AE of charged particles for identification by means of AE-E-correlations. 1 1 ~ time ] total light output [- E-total I. signal integration width Figure 4. left: The typical signal shape of BaF2 for photons and charged particles. The integration gates for signal processing are indicated, right: Particle identification based on the correlation of the separately integrated yield of the fast and total light-output.

140 R. Nouotny/Nuclear Physics B (Proc. Suppl.) 61B (1998) 137-142 The shape of the BaF2-signal is extremely sensitive to the nature of the impinging particle. The contribution of the fast scintillation component (X = 195, 210 nm) to the total light output (dominated by the slow scintillation component at X - 320 nm) diminishes with the increase of the energy density deposited by the ionizing particles. Figure 4 illustrates schematically the typical response of photons and protons and the crude pulse-shape analysis performed in TAPS. 800 l 600 = 400 200 neutral events.~ " =..~/x.;:. (no veto s i g n a l ) ~ ~ r)~. -/ n(p) hadronic showers contribute differently to the fast scintillation component. Figure 5 shows as an example of the PSA two scatter plots of the fast scintillation component versus the total light output accumulated for neutral and charged events (identified by the CPV) from data taken in photonuclear reactions. A dynamic range up to approx. 250 MeV photon equivalent energy is displayed. As marked, the distinct lines correspond to leptons, pions, protons as well as photons. The lower branch in the plot for neutral hits can be addressed to secondary protons recoiled by high energy neutrons which interact in the crystal via (n,p)-reactions. Measurements of the response function of TAPS detectors to neutrons deduce an efficiency which approaches a nearly constant value of 17 % above 750 MeV kinetic energy of the neutrons. 0 ~,~ 800 r~ 600 400 i i i i i r i i i r i 400 800 charged events "."::~i~ (veto signal). ;~2~,:: e,~ P ~-- 450 - ~ 400 350 300 250 stopped particles MIP YZ t ~' photons 200 neutrons 400 800 total light output Figure 5. Scatter plot of the fast scintillation component versus the total light-output of a TAPS BaF2-detector. The correlation pattern is shown for neutral (top) and charged events (bottom) selected by the CPV system. It has been established that the ratio of both contributions remains constant over the full dynamic range up to relativistic and even ultra-relativistic energies [6]. E.M. and 50 100 150 200 250 300 350 400 450 500 E-total [MeV] Figure 6. Pulse-shape correlation of a 15 mm plastic-baf2 phoswich detector identifying reaction products from the collision 2 AGeV Ca + Ca measured at GSI, Darmstadt. The particle sensitivity can be further improved by a fast plastic scintillator (15mm NE102A) optically coupled to the front face of the BaF2-crystal in phoswich technique [7]. The energy loss of charged particles in the

R. Nouotny/Nuclear Physics B (Proc. Suppl.) 61B (1998) 137-I42 141 plastic layer leads to a substantial increase of the total fast light output. The corresponding pulse-shape correlation is illustrated in Figure 6 identifying reaction products from the collision 2 AGeV Ca + Ca. Structures in the scatter plot above the clearly distinct branch due to photons can be assigned to charged particles either stopped within the AE-section or fully or partly stopped within the BaF2-crystal. The distinct area near Etotal-170 MeV is caused as an artifact by minimum ionizing particles generating additional Cherenkov photons within the quartz window of the photomultiplier. Again, neutrons identified via (n,p)-reactions can be observed below the proton branch well separated. 0.06 mt~0.04 t~ 0.02 Ep c~ _ 0.79% +1.80% Ep ~ Ey 0.59% +1.91% ~ E v o,... 0'2 0'3 o:; o; ;'6 oi, 08 incident photon energy [GeV] Figure 7. Energy resolution of the total light output (stars) and the fast scintillation component (crosses) as a function of the incident photon energy. The energy dependence has been parametrized by cr / E = A / ~-ff + B as shown in the figure. 2.3. Response to electromagnetic probes The photon response of TAPS has been determined in the energy regime up to 800 MeV using monochromatic photons provided by the tagging facility of MAMI at Mainz [8]. The experimental results are shown in Figure 7. The excellent energy resolution for a collimated photon beam (0 = 1.3 cm) amounts to (7 / E = 0.59% E~ l/~ + 1.9% (E~ given in GeV) and (7/E=0.79%E~ ~/2+1.8% fi)r the fast component, respectively. The achieved resolution at 1 GeV of a/e=2.5% is comparable to operating 4n-calorimeters such as L3, CleoII or Crystal Barrel, respectively. The obtained experimental data can be well reproduced by GEANT3-simulations taking into account the exact geometry, dead material such as reflector or light tight housing and experimental thresholds. The point of impact can be reconstructed from the electromagnetic shower distribution within the cluster of responding detectors with a resolution Ax < 2 cm limited due to the large diameter of the crystals. In spite of the insufficient depth of the crystals (12Xo) an energy resolution for 10 GeV electrons ofcr/e=5.1% has been achiew.~d within a cluster of only 7 modules. 3 NEUTRAL MESON SPECTROSCOPY Within the last few years of operation TAPS has pursued a broad and versatile research program which covers topics such as the early phase of nuclear reactions and energy dissipation mechanisms via the detection of hard photons below 100 MeV/u projectile energy. In the I GeV/u regime, the investigation of baryonic excitations in nuclei via photonuclear reactions and the study of hot and dense nuclear matter via the production and propagation of neutral mesons represent the main experimental goals. In particular, the meson reconstruction in heavy ion collisions relies on the efficient neutral and charged particle discrimination provided by TOF- and PSA-techniques as illustrated in the previous sections. The very good energy resolution achieved with BaF2

142 R. Nouotny/Nuclear Physics B (Proc, SuppL) 61B (1998) 13~142 allows an invariant mass resolution of typically 8-15% (FWHM) which is necessary to identify the weak meson signal on top of a huge combinatorial background in the invariant mass spectrum. Figure 8 shows an example taken at the so far highest bombarding energy of 450 GeV/c p+be operating TAPS assembled in a supercluster in coincidence with the dilepton spectrometer CERES at CERN-SPS [6]. 3oo - I I /~ TAPS data 1 o / ~-- p~be,t... f,,,[... I... I... I....... 100 200 300 400 500 600 700 800 invariant mass mw [MeV/c 2] Figure 8. Invariant mass distribution measured with TAPS at the CERN-SPS in the system 450 GeV/c p+be in coincident operation with the dilepton spectrometer CERES. In the lower part the combinatorial background has been subtracted. 5 SUMMARY The BaF2-calorimeter TAPS - designed for high energy photon detection - is operating very successfully since several years as an European device with high performance and 10 10 allows high resolution photon and particle spectroscopy [9]. The excellent and unique properties of the fast scintillator material BaF2 such as time response and pulse-shape sensitivity and the combination with plastic scintillators in different concepts guarantee the required clean, selective and efficient photon detection. The various instrumental techniques and geometrical arrangements made it possible to adjust to the experimental constraints imposed by the very widely scattered physics program. The proposed coincident operation with future generation detector systems such as the dilepton spectrometer HADES at GSI requires as a new major milestone the implementation of much faster analog and logic electronics and a highly selective 2 nd level trigger processor which are under development now. REFERENCES 1. R.Novotny, IEEE Trans. Nucl. Sci. 38 (1991) 379 2. The TAPS collaboration: NPI, Rez (Czech Republic), GANIL, Caen (France), GSI, Darmstadt, University Giessen, University M(inster (Germany), KVI, Groningen (The Netherlands), IFIC University Valencia (Spain) 3. R.Novotny et al., Nucl. Instr. and Meth. in Phys. Res. A262 (1987) 340 4. manufactured by Dr. Karl Korth, Kiel, Germany 5. O.Schwalb et al., Nucl. Instr. and Meth. in Phys. Res. A295 (1990) 191 6. M.Franke, M.Notheisen, PhD thesis, University Giessen (1996), to be published 7. R.Novotny et al., IEEE Trans. on Nucl. Sci. 43 (1996) 1260 8. A.Gabler et al., Nucl. Instr. and Meth. in Phys. Res. A346 (1994) 168 9. H.StrSher, Nuclear Physics News 6 (1996) 7