1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target



Similar documents
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

PANASONIC TROUBLE SHOOTING GUIDE

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

14. Troubleshooting Guide

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Failure code manual. content

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

Split and Multi Split air conditioners Service information

Simple Self-Diagnosis by Malfunction Code

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

USER S MANUAL HSC-24A

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Technical service manual

How To Power A Car With A Fan And A Fan (Power)

Technical service manual 2009

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit

Service manual. The voltage in P3 and P4 in outdoor PCB is high voltage about 310V The voltage in P5 and P6 in outdoor PCB is high voltage about 310V

REMOTE CONTROL MANUAL

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Panasonic/Sanyo A/C Interface Modbus RTU Installation Instructions

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Haier Air conditioner

SERVICE MANUAL INDOOR UNIT

HITACHI INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

*.ppt 11/2/ :48 PM 1


SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC

T-100-R Installation Guide

Air Conditioning System

, User s Manual

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Technical Information

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

Appendix - Controllers 179

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

SiUS Service Manual. RZR-P, RZQ-P(9) Series Cooling Only / Heat Pump R-410A 60Hz

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

york air-conditioning products Residential & VRF News 2015

Install Guide CT101. Caution. Caution

AIR CONDITIONING & HEAT PUMP SYSTEMS

HEATER, AIR CONDITIONING AND VENTILATION

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Midea Commercial Air Conditioner Malfunction Handbook

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Oil and Coolant Circulating Heating System. Model - OCSM

PART 1 PRODUCT (GENERAL)...1.

Fire Alarm Control Panel. Family. Operating Manual

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Features of your Air to water heat pump

Professional Contractor INSTALLATION GUIDE

SERVICE MANUAL AE-X2M14LR MULITI SPLIT TYPE ROOM AIR CONDITIONERS (OUTDOOR UNIT) MODEL. No. S2038AEX2MLRT CONTENTS AEX2M14LR

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

HP switch LP switch Discharge thermo Comp. Surface thermo

Contents. Introduction

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series

FILE NO. SVM HOW TO DIAGNOSE THE TROUBLE

10.1 Indoor Unit Error Display

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

User Guide Reflow Toaster Oven Controller

Split Air Conditioner

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

Table Z. Troubleshooting Chart for Air Conditioners. Cause

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

How To Wire Wire Wire A Power Supply On A Powerline (Powerline) From A Powerstation To A Powerplant (Powerplant) (Powerplant) (Control Board) (Wire) (Switchboard) (Wired) (

SWIMMING POOL HEAT PUMP Owners Manual

INDEX MITSUBISHI HEAVY INDUSTRIES - PAC SERVICE MANUAL MAINTENANCE DATA 2 ERROR CODES 4 PCB INDOOR UNITS 8 ERROR DISPLAY & REMEDY CHART 12

INSTALLATION AND OPERATION MANUAL

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Instruction manual for Firstline FCS12000CH

Install Guide 3M-50. Caution. Caution

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SERVICE MANUAL INDOOR UNIT

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

SERVICE & MAINTENANCE MANUAL

Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.

SERVICE MANUAL. Model No. HSU24VHJ(DB) Wall mounted Type DC Inverter EA-Series WARNING. Haier Group. Order No.AC1101S021V0

SMM. Installation Operation Maintenance

QUICK REFERENCE. Wired remote controller BRC2E52C7 BRC3E52C7

DUCT TYPE AIR CONDITIONER

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Split Air Conditioner

Transcription:

4-2 ABNORMAL OPERATI 4-2-1 An is represented by 3 digit characters. The first 2 digit means the subsection, and the last 1 digit means the specifics. Ex.) Indoor unit Network communication Error Subsection Error Code. 3 Specifics Error Code 14 : Network communication Error 3 : Indoor unit Network Communication Error Each section is shown by the following target Subsection Error Code target - Indoor unit (Operation / Timer / Filter) LED - 2 / 3 Wires Remote controller - Simple Remote controller - Group Remote controller - Central Remote controller - Touch - Panel Controller Subsection and Specifics target - Outdoor unit 7 segment - Service Tool When an Error occurs, each devices indicate own abnormal detecting condtion. In order to confirm the actual error condition, the following procedure are required. 1) Confirm the Specific on the Outdoor unit 7 segment display or the Service tool. Ex.1.) When the wired remote controller shows " (Outdoor unit Error)". Ex.2.) When the wired remote controller shows " 4 2 (Indoor unit Heat-Ex Sensor Error)" The Specific can be indicated by service tool. 2) Confirm each on each devices in case of Network communication Error. Ex.) When the Network cable of indoor unit 00 disconnected during operating. 14.2 " No communication between indoor unit 00 " - DipSW 4-2: Default Setting - Outdoor unit 14.1 or 14.3 Service Error indication pattern Tool "14.1": No communication between Outdoorunit and Service tool. "14.3": Communication Error on the Indoor unit. RB unit RB unit Indoor unit 00 Indoor unit 01 Touch-panel Controller "14" 16 Error indication pattern "14": Error on the Outdoorunit (14.2) "16": The Communication Error between Touchpanel controller and Error indoor unit. Operation LED: 1 time blinking Timer LED: 4 times blinking 14 Wired remote controller "Network communication Error" Indoor unit detects the condition of 14.3, but it can only display the Subsection. Note: About Service tool - To change the connecting location of service tool can be helpful for the trouble shooting. - To check the system configuration, the Address checker function can be helpful for trouble shooting. 04-03

4-2-2 Indoor Unit Error Indication Flashing Pattern Example : Indoor Unit Main PCB Error (Operation LED : 3 times, Timer LED : 2 times) 1 cycle Operation LED 1.0s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 3.0s 1.0s Timer LED 4.0s 1.0s 0.5s 0.5s 0.5s 0.5s 4.0s 0.1s / 0.1s Filter LED 4-2-3 Outdoor Unit LED display POWER MODE LED101 (GREEN) ERROR LED102 (RED) POWER MODE LED : on ERROR LED : blink POWER LED101 ERROR LED102 0.1sec 0.1sec Operation button MODE EXIT SELECT ENTER SW107 SW108 SW109 ERROR transition Short press : less than 3 seconds Long press : more than 3 seconds Annunciation "Err." and quantity are alternately shown. Type of errors ex : discharge thermistor 1 abnormal ex : indoor unit abnormal "SELECT" short press display change If some error is newly occured or resolved during transition, it is reflected after going back to "Annunciation". When there is more than one error, display is changed by "SELECT" short press. "ENTER" long press Address "SELECT" short press display change Only in the case of "indoor unit abnormal (E.5U.1)", indoor unit address is shown by ENTER long press. When more than one indoor unit is abnormal, display is changed by "SELECT" short press. 04-04

4-2-4 Remote Controller << SIMPLE REMOTE CTROLLER >> If an error occurs, the following display will be shown. ( will appear in the set room temperature display.) If is displayed, immediately contact authorized service personnel. Faulty unit No. (Remote controller address) << WIRED REMOTE CTROLLER 3 wire type>> If an error occurs, the following display will be shown. ( will appear in the set room temperature display.) If is displayed, immediately contact authorized service personnel. Unit number (usually 0) << WIRED REMOTE CTROLLER 2 wire type>> If an error occurred, an error icon appears on the Monitor mode screen. Conference Mode Set Temp. Fri 10:00AM Fan -Status Air Flow Direction VT1 1 Economy Off Hz 3 Anti Freeze Off Page 1/2 Error Information Page 1/3 Error Code Address 12, 14 2-16 Indoor unit -Status Menu Monitor Next Page Error Information Back Next Page 1. Touch the [Status] on the Monitor mode screen. 2. Touch the [Error Information] on the Status screen. 2-digit numbers are corresponding to the error code << GROUP REMOTE CTROLLER >> The air conditioning system must be inspected if : (error code) appears on the timer and Clock, or the operation lamp is flashing. Model code 1 1 ; Model code : Outdoor unit : Indoor unit : Group remote controller : Convertor 04-05

4-2-5 shooting index - List 1/2 - Simple Wired remote controller 2 / 3 wires Wired remote controller Indoor unit LED brinking times, " 1st figure: Operation LED, 2nd figure: Timer LED" Target A 1 2 Target B 1 3 2 9 6 1 6 2 6 3 6 8 Target A Target B Target C Target D < Subsection > Remote controller Communicaction Error Communication Error between Outdoor unit Network Communication Error Peripheral device communication Error Address settingerror Other setting Error Connection unit number error in wired remote controller system Indoor unit Power supply Abnormal Indoor unit Main PCB Error Indoor unit communication circuit (WRC) error Indoor unit Room temp. Sensor Error Indoor unit Heat-Ex. Sensor Error Indoor unit FAN Motor 1 Error Indoor unit Coil (EEV) Error Indoor unit water drain Abnormal Indoor unit Error Outdoor unit Power supply Abnormal Outdoor unit PCB Error Outdoor unit Inverter PCB Error OU. short interruption detection protected operation Outodoor unit Magnetic relay Error Outdoor unit Transmission PCB Error Outdoor unit Discharge temp. Sensor Error Outdoor unit Compressor temp. Sensor Error Outdoor unit Heat-Ex. temp. Sensor Error Outdoor temp. Sensor Error Suction gas temp. Sensor Error Heat sink temp. Sensor Errorl Sub cool HEX temp. Sensor Error Liquid pipe temp. Sensor Error Current Sensor Error Group Remote controller Central Remote controller Touch- Panel controller : No A: LED 10 times Blinks J: LED 13 times Blinks U: LED 15 times Blinks 2 6 2 9 3 1 3 2 3 A 4 1 4 2 5 1 5 2 5 3 6 9 7 1 7 2 7 3 7 4 7 5 7 7 8 2 8 3 8 4 Target C 2 8. 1 2 8. 4 1 3. 1 6 1. 5 6 2. 3 6 2. 6 6 2. 8 6 3. 1 6 7. 2 6 8. 2 7 1. 1 7 2. 1 7 3. 4 7 3. 5 7 3. 6 7 3. 7 7 4. 1 7 5. 1 7 7. 1 8 2. 2 8 3. 1 8 3. 2 8 4. 1 Target D 1 2. 1 1 2. 2 1 2. 3. 1. 1. 3. 2. 2. 1. 3. 1. 3. 2. 1. 2. 5. 5. 3. 1. 2 5 U. 1 5 U. 1 6 9.1 6 9.1. 3 2 6. 4 2 6. 5 2 9. 1 3 1. 3 3 2. 1 3 2. 3 3 A. 1 4 1. 1 4 2. 1 4 2. 3 5 1. 2 5 2. 1 5 3. 1. 1. 3 04-06 7 seg. on Outdoor unit Controller PCB Service Tool < Supecifics > Wired Remote Controller communication Error Wired Remote Controller singnal error ( 3 wires RC) Number Excess of device in Wired RC. System (2 Wires RC) Communication Error Between Outdoor unit Outdoor unit Network communication 1 Error Outdoor unit Network communication 2 Error Indoor unit Network communication Error The number of indoor unit shortage Error Transmission PCB connection Error Communication Error between Controller and Indoor unit Address duplication in Wired remote controller system Address setting Error in Wired remote controller system Auto address setting Error Signal amplifier auto address Error Connection unit number Error (Indoor unit in WRC control system) Connection unit number Error (Remote controller) Indoor unit power frequency Abnormal Indoor unit PCB Model informaiton Error Indoot unit EEPROM access Error Indoor unit communication circuit (WRC) microcomputers communication error Indoor unit Inlet air temp. Sensor Error Indoor unit Heat-Ex. Inlet temp. Sensor Error Indoor unit Heat-Ex. Outlet temp. Sensor Error Indoor unit FAN Motor 1 rotation speed Error Indoor unit Coil 1 (EEV) Error Indoor unit Drain pump Error Indoor unit Error Outdoor unit reverse phase, missing phase wire Error Outdoor unit EEPROM access Error Inverters communication Error EEPROM data corrupted Error Inverter Error Inverter PCB short interruption Error Rush Current limitting resistor temp. rise protection Outdoor unit transmission PCB Parallel communication Error Discharge temp.sensor 1 Error Compressor temp. Sensor 1 Error Heat-Ex 1 gas temp. Sensor Error Heat-Ex 1 liquid temp. Sensor Error Heat-Ex 2 gas temp. Sensor Error Heat-Ex 2 liquid temp. Sensor Error Outdoor temp. Sensor Error Suction gas temp. Sensor Error Heat sink temp. Sensor Error Sub cool HEX gas outlet temp. Sensor Error Liquid pipe temp. Sensor 1 Error Liquid pipe temp. Sensor 2 Error Current sensor 1 Error shooting No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Refer to I.U Error 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47

4-2-5 shooting index - List 2/2 - Simple Wired remote controller 2 / 3 wires Wired remote controller Indoor unit LED brinking times, " 1st figure: Operation LED, 2nd figure: Timer LED" Target A Target B 8 6 9 3 9 4 9 5 9 7 9 A 1 A 1 A 3 A 4 A 5 A 6 A C Target A Target B Target C Target D Compressor start up Error Trip Detection Compressor motor control Error Outdoor unitfan Motor 1 Error Outdoor unit coil (EEV) Error Outdoor unit Abnormal Discharge temp. Abnormal Compressor temp. Abnormal Pressure abnormal 1 Pressure abnormal 2 Heat-Ex temp. Abnormal Ambient temp Abnormal RB Unit Error < Subsection > Group Remote controller Central Remote controller Touch- Panel controller : No A: LED 10 times Blinks J: LED 13 times Blinks U: LED 15 times Blinks J 1 J 1 Pressure Sensor Error Target C 8 6. 1 8 6. 3 8 6. 4 9 3. 1 9 4. 1 9 5. 5 9 7. 1 9 7. 5 9 7. 9 9 A. 1 9 A. 2 9 A. 3 1 A 1. 1 A 3. 1 A 4. 1 A 4. 2 A 5. 1 A 6. 3 A 6. 4 A C. 4 Target D 5 U. 1 J 1. 1. 1. 1. 2. 2. 3 J 1. 4 Initial Setting Error - - - - 1: Master Outdoor unit :. 2 / Slave Outdoor unit and Service Tool indicate applicable 7 seg. on Outdoor unit Controller PCB Service Tool Discharge pressure sensor Error Suction pressure sensor Error High pressure SW 1 Error Inverter compressor Start up Error Trip detection Compressor motor loss of synchronization Outdoor unit FAN Motor Lock Error Outdoor unit FAN Motor temp. Abnormal Outdoor unit FAN Motor Driver Abnormal Coil 1 (EEV) Error Coil 2 (EEV) Error Coil 3 (EEV) Error Slave out door unit Eror Discharge temp. 1 Abnormal Compressor 1 Temperature Abnormal High pressure Abnormal High pressure protection 1 Low pressure Abnormal < Supecifics > Outdoor unit Heat-Ex 1 Gas temp. Abnormal Outdoor unit Heat-Ex 2 Gas temp. Abnormal Outdoor unit Heat Sink temp. Abnormal RB Unit EEPROM Access Abnormal RB Unit transmission PCB2 parallel communication Error Initial Setting Error shooting No. 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 4-2-6 shooting index - No - Error condition shooting Indoor Unit - No Power (Except Wall Mounted ) Indoor Unit - No Power (Except Wall Mounted ) 72 Indoor unit - No Power ( Wall Mounted) Indoor Unit -No Power( Wall Mounted) 73 No Error Code System Abnormal Outdoor unit - No Power RB Unit - No Power No operation (Power is ) Outdoor unit - No Power RB Unit - No Power No operation ( Power is ) 74 75 76 No Cooling No Cooling / No Heating 77 Abnoemal Noise Abnormal Noise 78 Water leaking Water leaking 79 04-07