Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC



Similar documents
Features and Benefits

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

CONTENTS General features Front panel and buttons Installation List of the working parameters to be checked before starting the unit

BIOMEDICAL REFRIGERATORS

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Material test chamber with mechanical convection

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

MOUNTING AND OPERATING INSTRUCTIONS

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

HERZ-Thermal Actuators

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Incubator with mechanical convection

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Controller for temperature control - EKC 102 REFRIGERATION AND AIR CONDITIONING. Manual

Modbus Server SAMSUNG Air Conditioners

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Regolatori per Refrigerazione Digitali FR canali

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

Aerona Air Source Heat Pumps

INSTALLATION OPERATING & MAINTENANCE MANUAL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ALARMLINE ANALOGUE Linear Heat Detection System

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Process Alarm Solutions

Electronic Control Devices The European Product Catalogue 2007

WD-AMX Water Detection Controllers

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Electronic Control Devices The European Product Catalogue 2007

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Accesorios para el Traceado Eléctrico Industrial Industrial Heat Tracing Accesories

Inwall Room Temperature Unit

S G G S G G S G G S G G. FR / MF range. Deep Freezers & Plasma Storage Freezers

SERVICE MANUAL REFRIGERATION

KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION

Temperature & Humidity SMS Alert Controller

Application Engineering

STERILIZERS, LABORATORY DRYING OVENS

Split Controller. User Manual SM-SS-F 2009/01/04

Table of Contents. 1 - Specifications Installation Wiring User controls...7

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Undercounter & Slimline Cabinet Range HR/LR 120 HRB/LRB120 HR/LR 140 HR/LR 150 HR/LR 200 HR/LR 240 HR/LR 360 HR/LR 410

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

IntesisBox KNX LG Air Conditioning

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Computer Controlled Capacity Control Methods in Refrigeration, with SCADA and PID Control THARA2C/1

Freezers - Ultrafreezers. Platilab & Irilab Series

IntesisBox Modbus Server SAMSUNG Air Conditioners

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

A project to optimise quality and energy efficiency must include metering

4-Channel Thermometer / Datalogger

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

MP-4000 Alarm List (Software version or later)

Current Monitoring Kit QUICK START GUIDE

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

BR I Blood Bank Refrigerators

Plastic tube flowmeters Series PT/PS

Current Monitoring Kit

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

Heating Controller. Building Technologies HVAC Products

EK908FHL - Thermostat for floor heating

Air Conditioning System

Test equipment for temperature and its reduction

HACCP CONTROLLERS. Ullstrøm Fepo AS Kr. Augustsgt Oslo Tlf: Fax: MULTIFUNCTION CONTROLLERS x 74 -

Monitoring,Telemaintenance,... HACCP. Innovative Supermarket solutions. Tecnologia ed Evoluzione

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

T5000 T000 LCD Digital Fan Coil Thermostat

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

RZAHUC program version 1.1 Regulation for Reznor Air Handling Units

ASTRONOMICAL TIME SWITCH NFC Supported AR-02D-NFC (2 x 10A)

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Remote Monitoring and REC 501 Control Unit Product Guide

Heating oven with mechanical convection

Link SIP Door Phone. Manual V1.0. Linkcom France rue du Soleil Levant CLAMART Copyright 2008 Linkcom Tous droit réservés

USB-500/600 Series Low-Cost Data Loggers and Accessories

FX07 Field Controller

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Technical Information

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Application/Connection Examples

How To Program An Autodialer

Split units TH with hermetic compressors

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

RAINCONTROL LCD Special

Electronic, Digital and Mechanical Vibration Switches

Transcription:

HOJA TÉCNICA 1400H101 Edición 01 (02 de 08) www.ako.es GENERAL TECHNICAL SPECIFICATIONS Temperature range: -50ºC to +99ºC type: NTC Total accuracy ( + controller): ±1ºC lead extension with cable AKO-15586: Max. decrease 0.35ºC for each 100m Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC Installation category: II in accordance with the CEI 664 standard REFERENCE DIAGRAMS ON FOLLOWING PAGE The following diagrams represent concepts, each controller includes its diagram with terminal numbering for correct connection. 1 2 0V 12V 24 3 4 0V 12V 24 Control Control 5 6 Control Digital input R2 7 8 Digital input Digital input S3 ALARM 9 10 To controller Slave relay

HOJA TÉCNICA 1400H101 Edición 01 (03 de 08) www.ako.es REFERENCES AND SPECIFICATIONS Wall mounting installation Installation with the slave relay for DIN 43880 rail mounting Panel mounting installation REFERENCES: AKO-14012 Thermometer 12/24V 1 AKO-14023 Thermometer 230V 2 AKO-14031 Thermometer 230V 2 AKO-14112 1 Relay 12/24V 3 AKO-14123 1 Relay 230V 4 AKO-14128 1 Relay 230V 5 AKO-14129 1 Relay 230V 4 AKO-14212A 2 Relays 12V 6 AKO-14223 2 Relays 230V 6 AKO-14312B 3 Relays 12V 7 AKO-14323B 3 Relays 230V 7 AKO-14412 4 Relays 12V 8 AKO-14423 4 Relays 230V 8 AKO-14530+AKO-15128 230V 9 AKO-14602 Thermometer 230V 2 AKO-14610 1 Relay 230V 4 AKO-14632 3 Relays 230V 10 SPECIFICATIONS Diagram for previous page 2 Digits, from -50ºC to + 99ºC 3 Digit decimal pt. from -49,9ºC to 99,9ºC 1, NTC 1,5m included, non-adjustable 1, NTC 1,5m included, adjustable 2, NTC not included 3, NTC not included Power supply 12 ± 20%, 50/60Hz Power supply 12/24 ± 10%, 50/60Hz Power supply 230 ± 10%, 50/60Hz Relay 1, Control (compressor) R 8(3)A, 250V, cos ϕ=1, SPST Relay 1, Control (compressor) R 8(3)A, 250V, cos ϕ=1, SPDT switch Relay 1, Control (compressor) R16(4)A, 250V, cos ϕ=1, Relay 1, Control (compressor) R16(4)A, 250V, cos ϕ=1, SPDT switch Relay 1, Control (compressor) R20(6)A, 250V, cos ϕ=1, Relay 1, Control (compressor) R 30 max.18(5)a, 250V, cos ϕ=1, SPST Relay 2, Defrost or fans R 8A, 250V, cos ϕ=1, SPDT switch Relay 2, Defrost R 8A, 250V, cos ϕ=1, SPDT switch Relay 2, Defrost R 8A, 250V, cos ϕ=1, SPST Relay 3, Fan R 6A, 250V, cos ϕ=1, SPST Relay 3, Fan R 8A, 250V, cos ϕ=1, SPST Relay 4, Alarm R 6A, 250V, cos ϕ=1, SPST Internal acoustic alarm Digital input (for voltage-free contacts) Real time clock Communications conector SPECIFICATIONS

HOJA TÉCNICA 1400H101 Edición 01 (04 de 08) www.ako.es REFERENCES AND PROGRAMMABLE AKO-14412, AKO-14423 4 relays, up to 3 sensors Compressor + Defrost + fans + Alarms AKO-14312B, AKO-14323B 3 relays, up to 2 sensors Compressor + Defrost + fans AKO-14530, AKO-14632 3 relays, up to 2 sensors Compressor + Defrost + fans AKO-14212A, AKO-14223 2 relays, up to 2 sensors Compressor + Defrost by electric heat or air AKO-14112, AKO-14123, AKO-14128, AKO-14129, AKO-14610, 1 relay, 1 sensor Defrost by compressor stop AKO-14031 Adjustable thermometer AKO-14012, AKO-14023, AKO-14602 Thermometers REFRIGERATION (Compressor) Min. S Def. Max. C0 1 calibration (Offset) -20ºC 0ºC +20ºC C1 1 differential (Hysteresis) 1ºC 2ºC 20ºC C2 Set point upper limit ( it cannot be set above this value) xxºc 99ºC 99ºC C3 Set point lower limit ( it cannot be set below this value) -50ºC -50ºC xxºc C4 Compressor protection delay type: 0=OFF/ON (from de last to switch-off) 1=ON (at swicht-on) 0 0 1 C5 Protection delay time (value for the option selected for parameter C4) 0min 0min 99min C6 "" relay status with faulty sensor 1 (1 relay equipment) 0=OFF/ON (average last 24 hours) 1=OFF/ON (to C7 and C8 program) 0 0 1 C6 C7 "" relay status with faulty sensor 1 (2, 3, 4, relay equipment) 0=OFF 1=ON 2=OFF/ON (to C7 and C8 program) ""relay (compressor) ON time in in case of sensor 1 failure if C7=0 and C8 0, the relay will always be OFF de-energised 0 1 2 0min 10min 99min C8 ""relay (compressor) ON time in in case of sensor 1 failure if C8=0 and C7 0, the relay will always be ON energised 0min 5min 99min ROST Min. Def. Max. d0 Elapsed time between 2 starts (1 relay equipment ) 0h 1h 99h d0 Elapsed time between 2 starts (2, 3, 4, relays equipment ) 0h 6h 99h d1 Maximum duration (1 relay equipment ) 0min 0min 99min d1 Maximum duration (2, 3, 4 relays equipment ) 0min 30min 99min d2 Type of message during defrost: (1=display the defrost start temp.) (0=display the actual temp.) (2=display the message df or def) 0 2 2 d3 Maximum time of message added at end of defrost 0min 5min 99min d4 2 final defrost start temperature (if it is programmed in P4) -50ºC 8ºC 99ºC d5 Defrost on equipment switch on: (0=no, first defrost according d0) (1=yes, first defrost according d6) 0 0 1 d6 Defrost start delay on equipment switch-off if d5=1 0min 0min 99min d7 d8 d9 Defrost type: 0=Electric heat 1=Hot gas bypass In 2-relay models for air defrosting, it is necessary to program F3 0 0 1 Time calculation between defrost periods: (0=Total real time) 1=Compressor operation sum) 0 0 1 Drip time, compressor stop and /R2 relay off when defrost ends In 2-relay, R2 operates in all cases of P6 0min 1min 99min d10 1st defrost hour start time 0 off 23 d11 2nd defrost hour start time 0 off 23 d12 3rd defrost hour start time 0 off 23 d13 4th defrost hour start time 0 off 23 d14 5th defrost hour start time 0 off 23 d15 6th defrost hour start time 0 off 23 S (Evaporator) Min. Def. Max. F0 2 fan stop temperatures (if it is programmed in P4) -50ºC 4ºC 99ºC F1 2 (F0) differential for switching the /R2 relay A1 and A2 Differential In 2-relay models if P6=1 and P4=1 1ºC 2ºC 50ºC F2 Stop fans if compressor stops? (0=no) (1=yes) (In 2-relay if P6=1) 0 0 1 F2 Stop fans if compressor stops? (0=yes) (1=no) 0 1 1 F3 Fan status during defrost (0=stopped) (1=running) 0 0 1 F3 Fan status during defrost (0=running) (1=stopped) 0 1 1 F4 Start-up delay after defrost (applicable if greater than d9) 0min 3min 99min F5 Stop fan if door opens? (0=no) (1=yes) 0 0 1

HOJA TÉCNICA 1400H101 Edición 01 (05 de 08) www.ako.es REFERENCES AND PROGRAMMABLE AKO-14412, AKO-14423 4 relays, up to 3 sensors Compressor + Defrost + fans + Alarms AKO-14312B, AKO-14323B 3 relays, up to 2 sensors Compressor + Defrost + fans AKO-14530, AKO-14632 3 relays, up to 2 sensors Compressor + Defrost + fans AKO-14212A, AKO-14223 2 relays, up to 2 sensors Compressor + Defrost by electric heat or air AKO-14112, AKO-14123, AKO-14128, AKO-14129, AKO-14610, 1 relay, 1 sensor Defrost by compressor stop AKO-14031 Adjustable thermometer AKO-14012, AKO-14023, AKO-14602 Thermometers ALARMS (Visual, acoustic or relay) Min. S Def. Max. A1 Maximum, ºC above the Set Point in sensor 1 0=off 0=off 99ºC A2 Minimum, ºC below the Set Point in sensor 1 0=off 0=off 99ºC A3 Start-up temperature alarm delay (if programmed in A1, A2) 0=off 0=off 120min A4 Temp. alarm delay from end of defrost 0=off 0=off 99min A5 Temp. alarm delay from the temperature at which they operate 0=off 30min 99min A6 Temp. alarm delay from digital input disable (door if P9=1) 0=off 0=off 126min A7 Temp. alarm delay from digital input enable (door if P9=1) 0=off 0=off 126min A8 Alarms if defrost ends for maximum time: (0=no ) (1=yes) 0 0 1 A9 OTHER FEATURES Min. Def. Max. P0 Type of operation: (0=Cold) (1=Heat) 0 0 1 P1 Relay for all function on power supply switch on 0min 0min 99min P2 Programmed parameter block : (1=yes, block) (0=no, unblock) 0 0 1 P3 Initial parameters: (1= yes, configure to "Def" and exit progr.) 0 0 1 P4 Connected sensors: (1= 1) (2= 1+ 2) (3= 1 + 2 + 3) 1 2 3 P4 Connected sensors: (0= 1) (1= 1+ 2) 0 1 1 P5 Adress for equipment with communication 0 0 126 P6 Relay 2 (R2) function: (0=defrost by electric heat) (1=fan control) 0 0 1 P7 Temperature display mode: (0=Whole) (1=One decimal) 0 0 1 P8 Displayed sensor: (1= 1) (2= 2) (3= 3) 1 1 3 P9 Digital input configuration: (0=disabled) (1=door) (2=external alarm) 0 0 2 P10 Contact with open door or disabled alarm: (0=open) (1=closed) 0 0 1 P11 Transfer parameters: (0=disabled) (1=send) (2=receive) 0 0 2 P12 Program version (information) r1 Clock configuration, Hour 0 x 23 r2 Clock configuration, Minute 0 x 59 EP Exit programming MESSAGES df AE AH AH AL AL Ar Fixed - Indicates defrost is being carried out. In order to display df o def when defrosting, it is essential that parameter d2 is set to option 2. Intermittent with temperature- External alarm (if P9=2) Intermittent with temperature- The sensor 1 temperature is between 99ºC< temp.<110ºc or exceeds the parameter temperature programmed in C2 Intermittent with temperature- The sensor 1 temperature exceeds that programmed in A1 Intermittent with temperature- The sensor 1 temperature is lower than that programmed in C3 Intermittent with temperature- The sensor 1 temperature is lower than that programmed in A2 Intermittent with temperature- Low-charge clock battery or non-programmed clock alarm E1 1 failure (open circuit, crossed, temp.> 110ºC ó temp.<-55ºc) E2 2 failure (open circuit, crossed, temp.> 110ºC ó temp.<-55ºc) E3 3 failure (open circuit, crossed, temp.> 110ºC ó temp.<-55ºc) EE Relay 4 alarm polarity configuration: (0=with alarm relay ON) (1=with alarm relay OFF ) 0 0 1 E5 Incorrect sensor configuration ( see P4, P8 ) Memory failure Messages E2 and E3 are displayed if P4 has been suitable programmed. Equipment operation under these conditions is the same as if P4 had been programmed with option 1

HOJA TÉCNICA 1400H101 Edición 01 (06 de 08) www.ako.es FRONT PANEL FUNCTIONS Increase button -When pressed for at least 5 seconds, a manual defrost is started with programmed duration. -In programming, it increases the value being displayed. -In 2, 3 and 4 relay models, it cancels the alarms, but they remain displayed. Decrease button -When pressed for at least 5 seconds, it displays the SET POINT temperature value. -In programming, it decreases the value being displayed. -In 2, 3 and 4 relay models, it cancels the alarms, but they remain displayed. MODELS WITH 1 RELAY: LED 1 LED 2 LED 1 Permanent: Indicates defrost in operation. LED 2 Permanent: Indicates compressor relay is ON. Flashing: Set Point or parameter programming phase. MODELS WITH 2, 3 AND 4 RELAYS: LED DT LED PR LED LED LED LED ALARM PR DT ºC PRG SET Increase button Decrease button Permanent: Indicates last defrost ended by time. LED PR Flashing: Set Point or parameter programming phase. LED Permanent: Cooling relay (compressor) energised. Flashing: Because of the temperature detected by 1 (TEM), the relay should be energised, but is not due to a programmed parameter. LED Permanent: relay energised. Flashing: Because of the temperature detected by 2 (), the relay should be energised, but is not due to a programmed parameter LED Permanent: Indicates defrost in operation. LED ALARM Permanent: ALARM relay energised (or acoustic alarm). Flashing: Alarm detected, relay de-energised, but display maintained. PRG ºC SET LED DT Increase button Decrease button - When the key is pressed for at least 5 seconds, it displays the current SET POINT and LED 2/PR flashes. -Pressing the or keys permits the SET POINT to be adjusted to the required value. - Pressing the and keys simultaneously sets the new value. When this operation is carried out, the display will return to the current temperature and LED 2/PR will cease flashing. Adjusting thermometer ref. AKO-14031 calibration Pressing the two keys simultaneously for at least 10 seconds displays the calibration value (default = 0ºC). Each press of the keys or will change the temperature display by 1ºC between -20ºC and +20ºC. The two keys should be pressed simultaneously again in order to accept the new value. The parameters should only be programmed or modified by personnel who are fully conversant with the operation and possibilities of the equipment. LEVEL 1 : - Pressing the and keys simultaneously for at least 10 seconds will cause LED 2/PR to indicate the programming phase and the first parameter C0 will appear on the display. - Pressing the key accesses the next parameter and the key will produce a return to the previous parameter. - If the and keys are simultaneously pressed in the last parameter EP, the controller will return to the temperature display situation and the LED 2/PR will cease to indicate the programming phase LEVEL 2 S: - In order to display the current value of any parameter, the keys and keys should be simultaneously pressed with the required parameter selected. Once it is displayed, it can be modified by pressing the or keys. - Pressing the and keys simultaneously sets the new value. When this operation is performed, the programming returns to Level 1 (parameters). NOTE: If a key is not pressed for 25 seconds in any of the previous steps, then the equipment will automatically return to the current temperature display situation without modifying any of the values. TEMPERATURE 10 Sec. LEVEL 1 LEVEL 2 S SIMULTANEOUSLY SIMULTANEOUSLY SIMULTANEOUSLY DISPLAY CHANGE NEW ACCEPT THE NEW PROGRAMMING ADJUSTING THE SET POINT TEMPERATURE The factory default value is 0ºC. 5 Sec. TEMPERATURE CHANGE SET POINT SIMULTANEOUSLY ACCEPT THE NEW DISPLAY SET POINT SET POINT NEW SET POINT EXIT PROGRAMMING

HOJA TÉCNICA 1400H101 Edición 01 (07 de 08) www.ako.es TRANSFER SERVERS AKO-14911 This is connected by means of the AKO-80018, 230/12V, to the power supply and it is programmed with the parameters that can be transferred to the AKO-14112 and AKO- 14123 units without these having to be powered. AKO-14916 Tabletop server which is connected by means of the AKO-80018, 230/12V, to the power supply. Permit to transfer parameters previously recorded in one server AKO- 14918, to the other controllers with communication connector without these having to be powered. AKO-14918 A portable server without supply to which, the parameters programmed in powered units with communication connector can be copied. The parameters may then be transferred from the server to other identical powered units. 230V AKO-80018 AKO-14911 230V AKO-80018 AKO-14918 AKO-14918 AKO-14916 Programming Transfer Transfer Transfer Power supply Programming AKO-14112 AKO-14123 AKO-14XXX With communication connector. AKO-14XXX With communication connector COMMUNICATION The units provided with a communications connector, permit data transmission and reception using the standard MODBUS protocol and to carry out management from PC software. This makes a centralised system for display, logging, alarms, remote teleprocessing AKO-80021 RS232/ converter module RS232 PC type computer AKO-5003 Software for controllers and data loggers using a PC type computer. On request software with: AKO data loggers with MODBUS communications protocol and output External alarms by telephone, fax or internet. CMOS Display boards. Power management. PLC management. Remote teleprocessing. AKO-14917 CMOS/ converter module AKO controllers with MODBUS communications protocol CMOS Up to 126 units and 1200m length. When over 32 units are installed the appropriate repeaters are needed.

HOJA TÉCNICA 1400H101 Edición 01 (08 de 08) www.ako.es ACCESSORIES Front protector DIMENSIONS Wall mounting AKO-14910 In transparent plastic for panel mounting units Sheath for housing sensors in tanks Power supply transformer Ø8 47 Ø3 90 NTC s AKO-14901 AKO-14902 AKO-14903 AKO-14906 L=1,5m L=2,0m L=3,0m L=6,0m L 14 Ø6 Modified polyolefin sheath and cable Tapered probe NTC sensor Ø3 Ø5 58 50,5 37 Ø7 35 10 23 79 140 11 37 3 14 17 Ø4 detail of fixing screw holes 60 80 120 AKO-155908 Stainless steel material Gas1/2" thread 34 DIN rail slave relay 90 Power supply converter AKO-15590 120-230/12V, 3VA 70 58 Panel mounting AKO-15589 17 14 to 30 /12, 6VA 58 33 extension cable 75 61,5 AKO-15586 3 x 0,5mm 2 cable with insulation + copper braid + PVC sheath. 28,5 70,5 100 mm 3 m AKO-14915 Stainless steel tapered probe with 3m silicone cable 190 mm 351400101 REV. 00 2002 D.L.: 41303-2002 Nos reservamos el derecho de suministrar materiales que pudieran diferir levemente de los descritos en nuestras hojas técnicas.