Test Report No: 10266255(15) Date: 05-Apr-12 Page 1 of 5



Similar documents
Test Report No. CTSSA/ /12 Date : 18/06/2012 Page: 1 of 5 CTS Ref. CTSPN/12/0437/Osram

Test Report No. F690101/LF-CTSAYAA

No. HKGEC Date: 26 Apr 2016 Page 1 of 6

TEST REPORT Page 1 of 9

The following merchandise was (were) submitted and identified by the client as : LAN CABLE LSZH 2006/01/ /01/05 TO 2006/01/19

Beysan San. Sitesi Fuar Cad. No: 27/A Beylikdüzü/İstanbul FAX NO : Attention : Şükrü Ulus Aktaş (kalite@tufankablo.

: EUROPE, ASIA, AFRICA, AMERICA

Organize Sanayi Bölgesi 21.Cadde No:1 ESKİŞEHİR FAX NO: Attention : Mustafa Günay (mgunay@doganglass.com)

Test Report. RLSHE Page 1 of 6. Report No.

Çetinkaya Pano Sac Tablo ve Plastik San. Tic. A.Ş.

TEST REPORT Job No./Report No TR Date:5 January 2015 Page 1 of 11

Elimination Of RoHS Substances In Electronic Products

Wurth Electronics Midcom Policy Statement on RoHS Compliance And Lead-Free Products

TEST REPORT Job No./Report No TR Date:12 June 2014 Page 1 of 5

Test Report No.: SDHGR CM Date: Jan.07, 2013 Page 1 of 12

Certificate of Analysis

RoHS Test Methods. Presented by: Bruce Peterson

TEST REPORT Page 1 of 6. Birikim Elektronik San. Tic. Ltd. Şti. Battery Directive (2006/66/EC) was performed on the item.

Which analytical tools/instruments/techniques are used for POPs. A general walk through the analysis

ECLIPSE MX. Motorized Fader Control Surface. Users Manual

Connection Cable for LED Driver Board

HS 1003 Part 2 HS 1003 Heavy Metals Test

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

RoHS CERTIFICATE OF COMPLIANCE FOR ACCUTOUCH SCREENS (Excluding AT4 Touch Screens)

Potassium Aluminium Silicate (Mica) Chemical and Technical Assessment (CTA) Prepared by Daniel E. Folmer, Ph.D., and reviewed by Madduri V. Rao, Ph.D.

One sample of Lineplus Powerline 2300 Highlighter (Orange-Blue-Yellow-Green-Pink) BUYER :

* TEST REPOR. TETAŞ Đç Ve Dış Ticaret A.Ş. Page 1 of 19 APPLICANT NAME

* TEST REPOR. TETAŞ Đç Ve Dış Ticaret A.Ş. Page 1 of 26 APPLICANT NAME

Analytical Test Report

Umur Kırtasiye San. ve Tic. AŞ. Neslihan Sözer Chemical Laboratory Manager

Directive 2000/53/EU on End-of-life vehicles (ELV) Screening SERBIA

TEST REPORT Page 1 of 6

Elemental Analyses by ICP-AES

TEST REPORT 26 October, 2005 Page 1 of 8

SANEM MATBAACILIK VE ULUSLARARASI TAŞ A.Ş.

DigiBlock Sample Preparation System APPLICATION NOTES LABTECH INC. Your Lab, Our Tech

TEST REPORT Job No./Report No TR R1 Date:9 July 2014 Page 1 of 12

TRU RoHS Products Test Report

R E S U L T S Page 1 of 8 REPORT : TURT February,2015

China RoHS Directive Legislation Compliance October 2011

TEST REPORT Page 1 of 9 TEXTILE LABORATORY MANAGER

Umur Kırtasiye San. ve Tic. AŞ. Neslihan Sözer Chemical Laboratory Manager

ANALYTICAL REPORT LABORATORY DETAILS. Telephone Facsimile . SGS Reference Report Number Date Reported Date Received

Product Regulatory Compliance Datasheet BE3600

Product Regulatory Compliance Datasheet NBU 5330

RoHS COMPLIANCE STATEMENT

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

TEST REPORT Page 1 of 5. Baksan Sanayi Sitesi 73.Blok No:8 ESKİŞEHİR TEL NO: Attention: Cengiz Serger (isikmaden@isikmaden.com.

RoHS RIA November 2003

Product Regulatory Compliance Datasheet ediscovery 8100

MARITIME AND PORT AUTHORITY OF SINGAPORE Merchant Shipping Act (Chapter 179) Merchant Shipping (Training, Certification and Manning) Regulations

CALL FOR OFFER. Győr Distillery Co. Ltd. (H-9027 Győr, Budai u. 7.) hereinafter referred to as Investor calls for offers in subject matter below

Technical Report No.: B. Rev. 00 Dated Parts of Ceiling Lamp and Parts of Spot Lamp

Product Regulatory Compliance Datasheet ediscovery 8200

Grades. Sodium Metabisulfite

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

aseries A13B Mini Bullet Camera User Manual

GBIC CWDM 40km Part no:

Dissolved and precipitated oxalate

Roza Tekstil Fermuar San. ve Tic. A.Ş.

TEST REPORT Page 1 of 7

TWO/FIFTY/TWO STEREO POWER AMPLIFIER

APPLICATION OF ICP-MS TECHNOLOGY FOR TRACE METALS ANALYSIS

Office 365 Data Processing Agreement with Model Clauses

NUTC R304. Use of Absorption Mechanisms to Decrease Heavy Metal Mobility

Enrollment for Education Solutions Addendum Microsoft Online Services Agreement Amendment 10 EES

Novel Method for Solid Phase Peptide Synthesis Using Microwave Energy

Crude Assay Report. Crude Oil sample marked. "AL SHAHEEN CRUDE OIL" dated 10th April On Behalf Of. Maersk Oil Qatar AS

Guidance and Reporting Instructions on Temporary E-reporting for the MATS Rule

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Microsoft Online Subscription Agreement/Open Program License Amendment Microsoft Online Services Security Amendment Amendment ID MOS10

EUROPASS DIPLOMA SUPPLEMENT

VALIDATION REPORT. Investigation of the major interferences for proposed Horizontal ICP AES method. ECN protocol

Allied Telesis and the Environment

TAIYO PSR-4000 AUS703

CB Test Certificates

EUDRAGIT E 100, EUDRAGIT E PO and

Introduction. The following definitions may help you better understand the components of the data report.

M I C R O W A V E E X T R A C T I O N S Y S T E M THE NEW MILESTONE MILESTONE

The ECN Concept for Quality Assurance of Compost

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

Universal Data Acquisition (UDA)

SODIUM CARBOXYMETHYL CELLULOSE

Secondary Lead Smelting

Keskin Color Kartpostalcılık A.Ş. Neslihan Sözer Chemical Laboratory Manager

Physical. Electrical. Environmental. Insulation: Contact: Plating: Temperature Rating: -55 C to +85 C

Test Report No.: GZ /CHEM Date: MAY 13, 2011 Page 1 of 6 (SVHC)

NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT

Measuring Protein Concentration through Absorption Spectrophotometry

Colorants for Plastics are our Playground PRODUCT STEWARDSHIP: ONE STEP AHEAD WITH CLARIANT

APPROVAL SHEET. Mid-tower computer case MODEL NO.: SPD202B-420W-PFC. Spire Corp.

TEST REPORT Job No./Report No TR R1 Date:9 July 2014 Page 1 of 17

FR Products for the Evolving Global Marketplace. Paul Killian Global Business Manager, TPE & FR Products

3M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series

Transcription:

Test Report No: 10266255(15) Date: 05-Apr-12 Page 1 of 5 Sumitomo Bakelite Singapore Pte Ltd 1 Senoko South Road Singapore The following sample(s) was/were submitted and identified by/on behalf of the client as: Sample Description : Lot No : Manufacturing Date : CRM-1084 2012026 09-01-12 Contact Name : Wong Mun Wei Contact Tel : +65-67503782 Contact Email : munwei@sbs.sumibe.co.jp Sample Receiving Date : 29-Mar-12 Testing Period : 29-Mar-12 to 05-Apr-12 Test Requested : In accordance with the RoHS Directive 2011/65/EU Annex II. Test Result(s) : Please refer to next page(s). Conclusion : Based on the performed tests on submitted sample(s), the results comply with the RoHS Directive 2011/65/EU Annex II ; recasting 2002/95/EC. Signed for and on behalf of Y.C. Tham Laboratory Manager This document is issued by the Company under its General Conditions of Service accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and

Test Report No: 10266255(15) Date: 05-Apr-12 Page 2 of 5 Test Result(s): Sample Description : Lot No : Manufacturing Date : CRM-1084 2012026 09-01-12 Test Item(s): Unit Method Results MDL RoHS Limit Cadmium(Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium (CrVI) Sum of PBBs Monobromobiphenyl Dibromobiphenyl Tribromobiphenyl Tetrabromobiphenyl Hexabromobiphenyl Pentabromobiphenyl Heptabromobiphenyl Octabromobiphenyl Nonabromobiphenyl Decabromobiphenyl Sum of PBDEs Monobromodiphenyl ether Dibromodiphenyl ether Tribromodiphenyl ether Tetrabromodiphenyl ether Pentabromodiphenyl ether Hexabromodiphenyl ether Heptabromodiphenyl ether Octabromodiphenyl ether Nonabromodiphenyl ether Decabromodiphenyl ether mg/kg With reference to IEC62321, n.d. 2 100 performed by UV/Vis Spectrometry mg/kg n.d. - 1000 With reference to IEC62321, mg/kg n.d. - 1000 performed by GC/MS

Test Report No: 10266255(15) Date: 05-Apr-12 Page 3 of 5 Note: (1) mg/kg = ppm ; 0.1wt% = 1000ppm (2) n.d.= Not Detected (3) MDL = Method Detection Limit (4) - = Not regulated (5) * : Exceeds limit Remarks: Sample received was totally dissolved by preconditioning method. Lab Analyst(s): Jay, Jojo and Eileen Sample photo: Sample Description : CRM-1084 Lot No : 2012026 Manufacturing Date : 09-01-12 Sample Submission Qty : 10gm SGS authenticate the photo on original report only

Test Report No: 10266255(15) Date: 05-Apr-12 Page 4 of 5 Process Flow of IEC 62321 (Pb, Cd, Hg & Cr 6+ ) Cutting / Preparation Sample Measurement Pb,Cd Acid digestion by suitable acid depended on different sample material Filtration Hg Microwave digestion with HNO3/HCl/HF Cr (Vl) Add appropriate amount of digestion reagent Heat to appropriate temperature to extract Solution Residue Cool, filter digestate through filter ICP-AES 1) Alkali Fusion 2)HCl to dissolve Add diphenyl-carbazide for color development Measure the absorbance at 540 nm by UV-VIS Remarks: Sample received was totally dissolved by preconditioning method. (CrVl method excluded)

Test Report No: 10266255(15) Date: 05-Apr-12 Page 5 of 5 Process Flow of PBBs and PBDEs by GC/MS (IEC 62321) First Testing Process Optional screen process Confirmation process... Cutting/Preparation Sample Pre-treatment Screening Analysis Solvent Extraction Concentrate/Dilute extracted solution Filter High Mass Range GC/MS Data ***End of Report***