GNS Managed Services Report For abcsun02



Similar documents
Department of Technology Services UNIX SERVICE OFFERING

G14 Unix Tools and Scripts to Monitor and Tune your Informix IDS Server

Cisco Active Network Abstraction 4.0

RAID Performance Analysis

Configuring Apache Derby for Performance and Durability Olav Sandstå

Agenda. Enterprise Application Performance Factors. Current form of Enterprise Applications. Factors to Application Performance.

VM-Series Firewall Deployment Tech Note PAN-OS 5.0

Virtuoso and Database Scalability

Hardware Performance Optimization and Tuning. Presenter: Tom Arakelian Assistant: Guy Ingalls

File System & Device Drive. Overview of Mass Storage Structure. Moving head Disk Mechanism. HDD Pictures 11/13/2014. CS341: Operating System

Red Hat Network Satellite Management and automation of your Red Hat Enterprise Linux environment

II. Installing Debian Linux:

Red Hat Satellite Management and automation of your Red Hat Enterprise Linux environment

Best Practices on monitoring Solaris Global/Local Zones using IBM Tivoli Monitoring

CELLTRACKS ANALYZER II. Networking Guide J40169EN

Uptime Infrastructure Monitor. Installation Guide

Cookbook Backup, Recovery, Archival (BURA)

TCP/IP Network Essentials. Linux System Administration and IP Services

OpenVMS Cluster Load Balancing

Heroix Longitude Quick Start Guide V7.1

Overview of I/O Performance and RAID in an RDBMS Environment. By: Edward Whalen Performance Tuning Corporation

CA Nimsoft Monitor. Probe Guide for CPU, Disk and Memory. cdm v4.7 series

ENTERPRISE INFRASTRUCTURE CONFIGURATION GUIDE

How To Install Openstack On Ubuntu (Amd64)

features at a glance

Best Practices for Monitoring Databases on VMware. Dean Richards Senior DBA, Confio Software

Server Management Tools (ASMT)

XTM Web 2.0 Enterprise Architecture Hardware Implementation Guidelines. A.Zydroń 18 April Page 1 of 12

System Requirements Table of contents

Monitoring Databases on VMware

Monitoring the Oracle VM Server

<Insert Picture Here> Oracle Database Support for Server Virtualization Updated December 7, 2009

Oracle Applications Release 10.7 NCA Network Performance for the Enterprise. An Oracle White Paper January 1998

HP LeftHand SAN Solutions

An Oracle White Paper May 2010 BEST PRACTICES FOR DATA RELIABILITY WITH ORACLE VM SERVER FOR SPARC

Cisco CRS-1/IOS-XR Device Management 3.5.2: Based on Cisco Active Network Abstraction Software

Where IT perceptions are reality. Test Report. OCe14000 Performance. Featuring Emulex OCe14102 Network Adapters Emulex XE100 Offload Engine

Backup architectures in the modern data center. Author: Edmond van As Competa IT b.v.

Devices and Device Controllers

BASIC TCP/IP NETWORKING

Hadoop. History and Introduction. Explained By Vaibhav Agarwal

Performance Comparison of Fujitsu PRIMERGY and PRIMEPOWER Servers

SUN ORACLE EXADATA STORAGE SERVER

UNISOL SysAdmin. SysAdmin helps systems administrators manage their UNIX systems and networks more effectively.

MICROSOFT EXCHANGE best practices BEST PRACTICES - DATA STORAGE SETUP

IVUE System Administration

SAN/iQ Remote Copy Networking Requirements OPEN iscsi SANs 1

Distribution One Server Requirements

Audit & Tune Deliverables

William Stallings Computer Organization and Architecture 7 th Edition. Chapter 6 External Memory

Secure Web. Hardware Sizing Guide

WHITE PAPER Improving Storage Efficiencies with Data Deduplication and Compression

Linux System Administration

Copyright 2013, Oracle and/or its affiliates. All rights reserved.

Tushar Joshi Turtle Networks Ltd

Agility Database Scalability Testing

Throughput Capacity Planning and Application Saturation

Analysis of VDI Storage Performance During Bootstorm

CONFIGURATION CONCEPTS SUN SPARC ENTERPRISE M-SERIES SERVERS. James Hsieh, Sun Systems Group. Sun BluePrints Online

Chapter 12: Mass-Storage Systems

SysAidTM Freeware Installation Guide

Isilon IQ Network Configuration Guide

Chapter 8: Installing Linux The Complete Guide To Linux System Administration Modified by M. L. Malone, 11/05

Monitoring IBM HMC Server. eg Enterprise v6

Configure Windows 2012/Windows 2012 R2 with SMB Direct using Emulex OneConnect OCe14000 Series Adapters

HOST AUTO CONFIGURATION (BOOTP, DHCP)

Oracle Clusterware and Private Network Considerations

Nimsoft Monitor. sysloggtw Guide. v1.4 series

Brainlab Node TM Technical Specifications

IP SAN Fundamentals: An Introduction to IP SANs and iscsi

Symantec NetBackup Getting Started Guide. Release 7.1

HP Storage Essentials Storage Resource Management Software end-to-end SAN Performance monitoring and analysis

OS Installation Guide Red Hat Linux 9.0

Deep Dive: Maximizing EC2 & EBS Performance

Introduction Disks RAID Tertiary storage. Mass Storage. CMSC 412, University of Maryland. Guest lecturer: David Hovemeyer.

Section 1: Preface Introduction... 1 Users... 1 Other Resources... 2 Conventions... 2 Icons... 2 Text... 2

IBM Tivoli Composite Application Manager for Microsoft Applications: Microsoft Hyper-V Server Agent Version Fix Pack 2.

Version Author(s) Web Description

IBM Tivoli Monitoring Version 6.3 Fix Pack 2. Infrastructure Management Dashboards for Servers Reference

ADSMConnect Agent for Oracle Backup on Sun Solaris Installation and User's Guide

VMWare Workstation 11 Installation MICROSOFT WINDOWS SERVER 2008 R2 STANDARD ENTERPRISE ED.

Aspen Cloud Server Management Console

Database Instance Caging: A Simple Approach to Server Consolidation. An Oracle White Paper September 2009

Bosch Video Management System High Availability with Hyper-V

Eliminate SQL Server Downtime Even for maintenance

Implementing Probes for J2EE Cluster Monitoring

virtualization.info Review Center SWsoft Virtuozzo (for Windows) //

Exadata and Database Machine Administration Seminar

Nasuni Filer Initial Configuration Guide

RSA Security Analytics Virtual Appliance Setup Guide

Introduction to I/O and Disk Management

Basic Installation of the Cisco Collection Manager

Enterprise Cloud. Customer Portal ver2.0 Manual. Ver.1.01

IBM Unica PredictiveInsight Version Publication Date: June 7, Recommended Software Environments and Minimum System Requirements

Configuring Apache Derby for Performance and Durability Olav Sandstå

ZFS Backup Platform. ZFS Backup Platform. Senior Systems Analyst TalkTalk Group. Robert Milkowski.

An Oracle White Paper September Highly Available and Scalable Oracle RAC Networking with Oracle Solaris 10 IPMP

Transcription:

GNS Managed Services Report For abcsun02 Report Date: 04-30-2008 Client Details: Name: ABC Funds Address: 242 West 30th Street, Suite 1005, New York, NY 10001 Contact: John Doe Host Details: Hostname: abcsun02 Location: 242 West 30th Street, Suite 1005 Manufacturer: Sun Microsystems Model: Sun-Fire-V240 Architecture: sun4u (sparc) CPU 2 * 1.28Ghz Ultra Sparc IIIi Disk: 4 * 73Gb (2 Mirrored pairs of 73Gb each, Solaris Volume Manager) Memory: 4GB OS: Solaris 8 (Generic_117350-46) Serial Number: FN44540080 Host Id: 839140E9 IP Address: 192.168.129.10 ILOM IP Address: 192.168.129.22 (Sun Sparc ALOM) Uptime: Mar 26 09:05 Software: Oracle, ABC Price Model Description: Production ABCPROD Oracle database and ABC Price Model server. There is a StorEdge 72Gb (Compressed) tape drive attached. Page 1 of 7

Disk Transfer displays performance statistics for data being read and written to disk. The first report lists the number of bytes being read from or written to the disk per second. The second report lists the number of read and write requests being issued per second. A single request typically reads or writes a large number of 512 byte blocks. The third report lists the average time the system spends servicing any one single read or write request. This time includes the seek, rotational latency, and data transfer times. As a general rule of thumb the disk will get busier (more data will be transferred, and more requests will be issued) as the application processing load increases. Page 2 of 7

Disk Transfer displays performance statistics for data being read and written to disk. The first report lists the number of bytes being read from or written to the disk per second. The second report lists the number of read and write requests being issued per second. A single request typically reads or writes a large number of 512 byte blocks. The third report lists the average time the system spends servicing any one single read or write request. This time includes the seek, rotational latency, and data transfer times. As a general rule of thumb the disk will get busier (more data will be transferred, and more requests will be issued) as the application processing load increases. Mount Dir Filesystem blocks used free %used / /dev/md/dsk/d10 5161518 1910700 3199203 38% /var /dev/md/dsk/d30 5181102 733230 4396061 15% /archive /dev/md/dsk/d70 10022380 5134138 4788019 52% /pas /dev/md/dsk/d80 41311843 19403246 21495479 48% /home /dev/md/dsk/d50 6013422 652814 5300474 11% /opt /dev/md/dsk/d40 9521261 2948390 6477659 32% /export /dev/md/dsk/d60 40364803 31374953 8586202 79% /space /dev/md/dsk/d90 17539178 3725811 13637976 22% The Disk Partitions table lists the actual physical size used for each logical mount point, when the report was run. For a mount point containing dynamically changing data a percentage used figure above 80 percent is cause for concern. For a mount point containing static data a percentage used figure over 90% is cause for concern. Page 3 of 7

The cpu usage report is divided into two parts. The upper part shows the percentage of total CPU power being used by the host. The lower part is the amount of unused idle CPU power that is available. In general the two parts of the graph have an inverse relationship. The following three categories are broken down to show how the CPU is being used: -User - Running user application instructions. -System - Running operating system instructions. -Waiting I/O - CPU idle while waiting for a disk I/O. In general on a properly tuned system the percentage of system CPU time should be several orders of magnitude less than the user CPU time. Waiting I/O CPU resources are available for other uses. In general any significant period of 0% Idle time, and 0% Waiting I/O time. indicates that the machine either needs more CPU power, or needs some other adjustment or system change. Page 4 of 7

The top report shows the amount of virtual memory available on the machine. As the machine gets busier, and more processes are run the amount of free virtual memory goes down. The bottom report shows the amount of physical memory that is available in kilobytes. In general the system should always have at least 1 GB of virtual memory, and 500 MB of physical memory available. memory page executable anonymous filesystem swap free re mf fr de sr epi epo epf api apo apf fpi fpo fpf 6594104 2815328 115 89 1 0 0 2 0 0 0 0 0 713 1 1 Swap Information total(gb) free(gb) %available 4.00 4.00 100 Page 5 of 7

I/O Statistics list the number of errors or problems related to all of the media devices. sd0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: SEAGATE Product: ST373307LSUN72G Revision: 0507 Serial No: 3HZ9EKZG00007515 sd1 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: SEAGATE Product: ST373307LSUN72G Revision: 0507 Serial No: 3HZ9ER5J00007516 sd2 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: FUJITSU Product: MAP3735N SUN72G Revision: 0401 Serial No: 00Q0J00A sd3 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: SEAGATE Product: ST373307LSUN72G Revision: 0507 Serial No: 3HZ941MW00007509 sd30 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: TEAC Product: DV-28E-C Revision: 1.4B Serial No: Size: 1.58GB <1580875776 bytes> st12 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: HP Product: C7438A Revision: ZP5A Serial No: 9 Appendix 1

Network Information: bge0: flags=1000843<up,broadcast,running,multicast,ipv4> mtu 1500 index 2 inet 192.168.129.10 netmask ffffff00 broadcast 192.168.129.255 groupname abc01 ether 0:3:ba:91:40:e9 bge0:1: flags=9040843<up,broadcast,running,multicast,deprecated,ipv4,nofailover> mtu 1500 index 2 inet 192.168.129.12 netmask ffffff00 broadcast 192.168.129.255 bge1: flags=1000843<up,broadcast,running,multicast,ipv4> mtu 1500 index 3 inet 192.168.129.13 netmask ffffff00 broadcast 192.168.129.255 groupname abc01 ether 0:3:ba:91:40:ea bge1:1: flags=9040843<up,broadcast,running,multicast,deprecated,ipv4,nofailover> mtu 1500 index 3 inet 192.168.129.19 netmask ffffff00 broadcast 192.168.129.255 bge2: flags=1000842<broadcast,running,multicast,ipv4> mtu 1500 index 4 inet 0.0.0.0 netmask 0 broadcast 255.255.255.255 ether 0:3:ba:91:40:eb bge3: flags=1000842<broadcast,running,multicast,ipv4> mtu 1500 index 5 inet 0.0.0.0 netmask 0 broadcast 255.255.255.255 ether 0:3:ba:91:40:ec Routing Table: IPv4 Destination Gateway Flags Ref Use Interface -------------------- -------------------- ----- ----- ------ --------- 192.168.129.0 abcsun02 U 1 6358 bge0 192.168.129.0 abcsun02-e1 U 1 634 bge1 192.168.129.0 abcsun02 U 1 0 bge0:1 192.168.129.0 abcsun02 U 1 0 bge1:1 BASE-ADDRESS.MCAST.NET abcsun02 U 1 0 bge0 default 192.168.129.1 UG 1 21608 Name Mtu Net/Dest Address Ipkts Ierrs Opkts Oerrs Collis Queue lo0 8232 127.0.0.0 127.0.0.1 1143959173 0 1143959173 0 0 0 lo0 8232 127.0.0.0 127.0.0.1 0 N/A 183 N/A N/A 0 bge0 1500 192.168.129.0 192.168.129.15 68206809 3055786 81269567 0 0 0 bge0 1500 192.168.129.0 192.168.129.15 28181937 N/A 583498298 N/A N/A 0 bge0:1 1500 192.168.129.0 192.168.129.18 0 N/A 0 N/A N/A 0 Appendix 2