Floor systems - key elements for sustainable multi-storey buildings



Similar documents
An innovative thermally activated light-weight steel deck system numerical investigations and practical tests

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Hoesch Matrix System individuell. ThyssenKrupp Steel Europe Thinking the future of steel

Federation of European Heating, Ventilation and Air-conditioning Associations

How To Design A Post Tensioned Deck For A Building

Energy-Plus Primary School, Hohen Neuendorf, Germany

Optimization of a Hybrid Ground Source Heat Pump using the Response Surface Method

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Crawl space heat and moisture behaviour

CRK24-B1 Heated/chilled ceiling system

Ampacity simulation of a high voltage cable to connecting off shore wind farms

SAFIR A software for modelling. to the fire

Integrated Solar Radiant Systems

ENERGY AUDIT. Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM):

New technical solutions for energy efficient buildings

New Thermal Architecture For Future Green Data Centres

Federation of European Heating, Ventilation and Air-conditioning Associations

HDA

8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS

Safe & Sound Bridge Terminology

Modular Accommodation Solutions. Flexibility, efficiency and quality in one complete package

Passive house rehabilitation of post war residential building in Zug, Switzerland

Smart building as a power plant energyplus house with energy charge management

Field test of a novel combined solar thermal and heat pump system with an ice store

Composite Construction with KÖCO- Stud Welding Technology IMPRESSIVE TECHNOLOGY 6/

Composite Panel Firewall Systems

POROUS BURNER - A New Approach to Infrared

Numerical modelling of shear connection between concrete slab and sheeting deck

Coupling Forced Convection in Air Gaps with Heat and Moisture Transfer inside Constructions

Steady Heat Conduction

Kerkstoel Activ Floors for concrete core activation

OEGNB - Open Source Building Assessment

Net Zero Station Design for The Cooper Centre for the Environmental Learning in Tucson, Arizona: Improving the performance of existing buildings

Egcobox Software Manuel Version Max Frank GmbH & Co. KG

Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D.

Response, Reliability and Results in the delivery of leak detection services

The calculus and simulation of underfloor heating systems

HANDOUT CLIMATIC WIND TUNNEL MAHLE BEHR GMBH & CO. KG STATUS: FEBRUARY 2014

Slab Track Austria. System ÖBB-PORR elastically supported slab

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Long-Term Hygrothermal Performance of Green Roofs

Calculation panel heating/cooling

COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS -

Radiant Heating and Cooling Systems BY KWANG WOO KIM, ARCH.D., MEMBER ASHRAE; BJARNE W. OLESEN, PH.D., FELLOW ASHRAE

School in Schwanenstadt, Austria

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

Fame Design Ltd (10295) Plot # A-115/116,BSCIC Hosiery I/A, Narayangonj, Bangladesh ( , ) 18.June.2014

SEISMIC RETROFITTING OF STRUCTURES

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

Drain Back systems Made in Germany

Moisture Content in Insulated Basement Walls

Formwork for Concrete

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

The simulation of machine tools can be divided into two stages. In the first stage the mechanical behavior of a machine tool is simulated with FEM

Annex of the certificate (Page 1/6) Accreditation Scope

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Nearly Zero-Energy Buildings Examples of the sector trade, commerce, services

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

Module 3.7. Thermal bridging

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Outline of the joint research project of SWT, ZfS, ISFH and FhG-ISE: Analysis and evaluation of large thermal solar combi-systems

EUROPEAN STANDARD EN 343:2003 PROTECTION AGAINST RAIN

TAX APPRAISAL DISTRICT OF BELL COUNTY STORES & COMMERCIAL IMPROVEMENT CLASSIFICATION GUIDE

Best Practice in Best Pra ctice in teel constr uction - onstr industrial B uildings esidential Buildings 01 Introduction 02 Key Design Factors

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Introduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)

Floor structures Building constructure 2 REINFORCED CONCRETE FLOOR STRUCTURES

Unbeatable energy efficient glass curtain wall system

Chapter 3 Pre-Installation, Foundations and Piers

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

The ACR : Advanced Design Features for a Short Construction Schedule

D5.1 Report on the needs to achieve improved fire protection as regards the implementation and development of the EN Eurocodes

Installation Instructions

The Central Solar Heating Plant with Aquifer Thermal Energy Store in Rostock - Results after four years of operation

Optimization of electronic devices placement on printed circuit board

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

MULTI-RESIDENTIAL BUILDING SOLUTIONS

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

COMMERCIAL BUILDING APPLICATIONS

Heat Pipe Selection Revision 12/04/2001

BOFIRE A FEM-programm for non-linear analysis of structural members under fire conditions

THERMAL LOSSES Thermal Losses Calculations

Thermal diffusivity and conductivity - an introduction to theory and practice

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Numerical Analysis of the Moving Formwork Bracket Stress during Construction of a Curved Continuous Box Girder Bridge with Variable Width

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Simulation of Residual Stresses in an Induction Hardened Roll

Status quo of stress simulation for hot and warm work piece temperatures in forging

MAJOR LEARNING OUTCOMES ARCHITECTURE AND URBAN PLANNING 1ST CYCLE PROGRAMS GENERAL ACADEMIC PROFILE

Transcription:

Floor systems - key elements for sustainable multi-storey buildings Döring, B., AAINA GmbH, Institute for sustainable construction Aachen, Germany (Presenting), bdo@aaina.eu; Kuhnhenne, M., RWTH Aachen, Institute for steel structures, Germany, mku@stb.rwth-aachen.de; Feldmann, M., RWTH Aachen, Institute for steel structures, Germany, fel@stb.rwth-aachen.de Summary In the design of floor systems a wide range of various aspects of sustainability have to be taken into account in parallel. The present report analyses selected floor systems regarding these criteria and outlines new developments for improving the sustainability of floor systems. The mechanical properties are enhanced by using composite effects or pre-stressing. These solutions have to be combined with the integration of a piping system to create thermo-active building components for energy efficient heating and cooling, acting mainly via the ceiling. For flexible installations openable cavities (access mainly from the floor) are needed. The integrated approach of these systems requires a high degree of prefabrication. Keywords: floor systems, sustainability, multi-storey buildings, DGNB 1. Introduction In the design of floor systems a wide range of various aspects of sustainability have to be taken into account in parallel: A flexible building use asks for long spans with minimized number of columns or massive walls, for low-exergy heating and cooling systems the large surface is beneficial, the mass of the slabs is the only relevant thermal inertia in modern office buildings. Additionally, acoustic aspects have to be considered, the floor system should provide a flexible routing to cover future demands concerning building services and IT and the quality and the quantity of the used materials referring the environmental impact (eco-balance) is of interest, too. The multiple impacts on the sustainability assessment of the flooring systems will be shown exemplary based on the german DGNB system to point out the advantages and disadvantages of the different solutions in this context. 2. Floor systems and sustainability 2.1 Relevant sustainability criteria for floor systems The definition of what sustainability is, has become more precise and more common during the last few years. Sustainability covers the three areas ecology, economy and social/functional. The existing sustainability assessment methods are based on criteria lists, which ask for details for describing the main areas. Floors are important in this context because they are responsible for about 60 to 80 % of the building mass. According to the german DGNB-label, floor systems are involved in 20 criteria of 34 criteria in total; due to different weighting factors they influences 56 % of the overall result [1]. The following criteria are of particular interest within this context: Ecology: - Eco-balance (production, use-phase, end of life)

Economy - Life-cycle costs - Flexibility in use Social / functional - Thermal comfort (impact by thermal inertia) - acoustics 2.2 Developments for improving sustainability of floor systems Improving sustainability of buildings is in general a task for the whole building design and not for a single element. Nevertheless, key elements for a whole building like floor systems have an substantial impact on the sustainability, therefore it is valuable to look at these elements in detail. Combining several aims in one technical solution offers good opportunities on this way. Two examples illustrate this way of thinking: a) Composite decks with profiled steel sheets Composite decks based on profiled steel sheets combine the following effects (beneath others): The use of profiled steel sheets reduces the mass of concrete, depending on the shape of the steel sheet (Fig. 1). Furthermore, longer spans can be realised and a third benefit is given by the fact, that the effective thermal inertia is higher due to the enlarged surface. This leads to better thermal behaviour, in particular in the summer case. Advantages in the three main areas of sustainability can be ascertained. Fig. 1 Composite deck [2] The effective thermal inertia was studied in detail for various profiles available on the market (Fig. 2 Fig. 4). For these deck systems the effective thermal inertia was determined based on an FEMsimulation and compered with the results of a conventional flat concrete slab. The simulation uses a sinusoidal temperature curve in the room below the deck element (T min = 18 C, T max = 26 C=. The heat, that is stored in the deck element in a quasi-stationary state (after 10 periods), was determined.

1 screed insulation concrete 40 130 steel sheet t = 1 36 12 Fig. 2 Holorib deck [3] screed insulation concrete 40 90 t = 1 580 210 reinforcement steel sheet 75 7 Fig. 3 Hoesch additiv deck [4] 183 screed insulation concrete 40 125 steel sheet t = 1 87 96 Fig. 4 ArcelorMittal Cofrastra deck [2] Fig. 5 compares the maximum heat flux q max into the different composite deck systems (and for comparison: a massive concrete deck of 10 cm, at which there is no remarkable difference in the thermal behaviour between 10 cm and 20 cm, e.g.). Additionally, the total heat per m² (q k ) is shown.

35 30. q max 3 300. q max [W/m²] 25 20 15 10 q k 2 200 1 100 q k [Wh/(m²d)] 5 0 Hoesch Holorib Cofrastra Massiv_10 0 Deck system Fig. 5 Comparison of thermal performance composite decks and massive concrete slab This diagram shows, that the effective thermal inertia is about 20 % higher for the profiled composite decks. The load bearing capabilities of these floor systems are considerable higher, thus a positive effect on the whole building assessment can be expected [5]. b) Thermo-active pre-stressed hollow core slabs Pre-stressed hollow core slabs have large spans and reduced mass. Pre-stressing leads to a higher utilization of the capabilities of concrete. The combination with thermal activation by an integrated pipe system gives added value: The deck element becomes an energy efficient an low cost heating and cooling system. Fig. 6 Fabrication of thermo-active concrete slab (on site)

Fig. 7 Fabrication of thermo-active hollow-core slab (in shop) Fig. 7 shows the fabrication of thermo-active pre-stressed elements in shop. Numerical investigations (Fig. 8) and practical testing (Fig. 9) of these elements verified, that the thermal performance of these elements is positive: the thermal intertia is sufficient for typical use of office buildings, the thermal resistance from the pipe to the surface and the equability of surface temperature are sufficient for an energy efficient use of these elements. Fig. 8 Thermal performance of thermo-active hollow core slab (FEM-result)

Fig. 9 Infra-red survey of thermo-active hollow core slabs in test rig. Finally, also for this floor system advantages in the three main areas of sustainability can be ascertained: Improvement of span and load bearing capabilities, reduced need of natural resources and positive impact on the energy efficiency. 3. Discussion Perhaps it is not directly obvious, that floor systems have a significant impact on the sustainability assessment of a building, but it can be shown that floor systems are relevant for a wide range of sustainability criteria. Remarkable progress is possible, if improved performance in different areas can be realized in parallel. The two examples combine larger spans with reduced need of material and a positive effect concerning thermal and energetic behaviour. 4. References [1] DGNB Handbuch, Deutsche Gesellschaft für Nachhaltiges Bauen, Stuttgart, 2009 [2] Arcelor Bauteile GmbH, 06796 Brehna, Produktinformationen: http://www.arcelorbauteile.de/produkte/cofrastra/index.htm [3] Richard Lees Steel Decking Limited, Ashbourne (GB), Produktinformationen: http://www.rlsd.co.uk/pdf/holorib.pdf [4] ThyssenKrupp Bausysteme GmbH, Siegen, Produktinformationen, http://www.tksbau.com/de/produkte/hoesch_additiv_decke [5] Döring, B.: Einfluss von Deckensystemen auf Raumtemperatur und Energieeffizienz im Stahlgeschossbau, Dissertation RWTH Aachen, Shaker-Verlag, Aachen, 2008