Let the BD FACSAria II accompany your best performance ever



Similar documents
BD FACSAria Flow Cytometer. The first high-speed sorter with a fixed-alignment cuvette flow cell from BD Biosciences

BD FACSAria Flow Cytometer. BD Biosciences Clontech Discovery Labware Immunocytometry Systems Pharmingen

BD FACSAria III User s Guide

BD FACSAria II User s Guide

BD FACSCanto Flow Cytometer. Efficient Easy Powerful

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

BD FACSVerse. Simply brilliant

Introduction to flow cytometry

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

Institut für Experimentelle Immunologie und Bildgebung

Introduction to Flow Cytometry

These particles have something in common

Preparing BD Systems for Data Migration. Summary of the Upgrade Process on page 6. Copying User Data Files onto an Upgraded System on page 7

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

Introduction to Flow Cytometry

BD FACSCanto II Flow Cytometer Reference Manual

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

Establishing Optimum Baseline PMT Gains to Maximize Resolution on BD Biosciences Digital Flow Cytometers

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

Flow Cytometry A Basic Overview

Welcome to More Choice BD Analyte Specific Reagent (ASR) Catalog

Introduction to Flow Cytometry:

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

Clinical and Laboratory Practices Workshops. Helping to improve laboratory skills and the quality of care in resource-limited settings

FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data. Monisha Sundarrajan, PhD BD Biosciences

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

BD FACSCalibur. The flow cytometer for your routine cell analysis needs

BD FACSCanto II Instructions For Use

APPLICATION INFORMATION

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

BD FC Beads 8-Color Kit for BD OneFlow Assays

BD LSR II User s Guide

BD LSRFortessa Cell Analyzer User s Guide

Flow Cytometry. flow cytometer DNA apoptosis ph

Boundary-breaking acoustic focusing cytometry

Advantages of the Alexa Fluor 488 secondary antibody conjugates

Easy to use. Compact. Flexible. Sorting Chip

BD StemFlow Human Pluripotent Stem Cell Sorting and Analysis Kit

BD Pathway Bioimaging Systems

Standardization, Calibration and Quality Control

Flow cytometry basics fluidics, optics, electronics...

Immunophenotyping peripheral blood cells

powerful. Intuitive. Customizable. The new star of benchtop flow cytometry

COMPENSATION MIT Flow Cytometry Core Facility

Information security guidelines

Below is a list of things you should be aware of before you schedule your sort.

Cell Sorting. S3e Cell Sorter Quick Guide

How to operate the BD FACSCanto flow cytometer

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

CyAn : 11 Parameter Desktop Flow Cytometer

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction

BD FACSComp Software Tutorial

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

BD Influx. A high-speed cell sorter that adapts to your way of thinking

ArC Amine Reactive Compensation Bead Kit

Getting Started with BD FACSDiva Software

GETTING STARTED. 6. Click the New Specimen icon.

Standard Operating Procedure

Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available!

Lab 2. Isolation of mononuclear cells from peripheral blood and separation into subpopulations

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Attune NxT Acoustic Focusing Cytometer

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

Cytell Cell Imaging System

FACS Laboratory. BD LSRs Operator Training. Training Guide.

BD LSR II and FACSDiVa Software. Dr. Jens Fleischer, Basel Dr. Norbert Leclere,, Berlin

Cell Discovery 360: Explore more possibilities.

FlowSight. Flow cytometry with vision

INSIDE THE BLACK BOX

BD FACSDiva TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY

1. Instrument Layout pg Summit Overview pg Data Storage and Data Files pgs Saving Data pg Start Up pg 8

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

FACSCalibur System User s Guide

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

Six Trends in Robotics in the Life Sciences

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

Cell Sorting. S3e Cell Sorter

ArtisanLink Staining System is an automated special stains slide

CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles

FACSCanto RUO Special Order QUICK REFERENCE GUIDE

Services. Contract. Optimize. Results. Instrument. Guidance. Reagent

LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size

Hoechst HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, )

Spherotech, Inc Irma Lee Circle, Unit 101, Lake Forest, Illinois

TROUBLESHOOTING FLOW CHART

Cell Viability You Can Count On

Three Rules for Compensation Controls

Science is hard. Flow cytometry should be easy.

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

CyAn ADP with Summit Software User Guide

Fluorescent Array Imaging Reader

Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides

Chapter 12 Filters for FISH Imaging

flow cytometry reinvented

Zeiss 780 Training Notes

SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

Transcription:

Let the BD FACSAria II accompany your best performance ever

Meet the new BD FACSAria II high-speed, fixed-alignment cuvette cell sorter. The first generation BD FACSAria system brought the complex world of cell sorting to a broader audience of researchers. Now the new BD FACSAria II system makes cell sorting even easier and more accessible. Designed with input from customers around the world, the new BD FACSAria II improves ease of use, flexibility, and aseptic capability to make it simply the best choice for consistent results in sorting across a broad range of applications. The BD FACSAria II incorporates the unique fixed alignment technology that revolutionized cell sorting over five years ago with the introduction of the BD FACSAria. Fixed alignment minimizes startup time and improves reproducibility. Gel coupling to the objective lens improves collection efficiency and increases sensitivity and resolution needed for multicolor sorting applications. The BD FACSAria II advances cell sorting with multiple improvements including: New fluidics and nozzle designs A new fluidics design improves aseptic setup and cleaning. New nozzle sizes enable a wide range of particles to be sorted and new nozzle design allows for reproducible insertions. Software wizards and automation simplify aseptic sort setup, drop delay determination, and clog detection. Better workflow and productivity The BD FACSAria II also raises the bar on ease of use to improve both workflow and productivity with improvements across the platform. For example, a universal sort tube collection mount now makes it easier to insert and remove tube holders. In addition, software improvements dramatically cut the time spent on cytometer setup, adjustment, and maintenance. New 375-nm Near UV laser The 375-nm Near UV laser option is available to expand the range of application choices. The beam geometry is optimized for most hematopoietic stem cells. The top hat design of the 375-nm Near UV laser triples the amount of light at the sample intercept. The 375-nm Near UV laser can be operated together with the red and blue lasers. Upgrades from BD FACSAria to BD FACSAria II Packages will be available to field upgrade BD FACSAria instruments to the capabilities of the BD FACSAria II. Discover what makes the BD FACSAria II the platform of choice worldwide then let it accompany your best performance ever.

FLUIDICS First II Deliver New fluidics design enables easy aseptic setup and effective cleaning. The fluidics system moves particles from the sample injection chamber through the cuvette flow cell for interrogation and sorting into a collection device. Aseptic setup and cleaning are achieved through a new fluidics design that is both effective and easy to use. It features integrated valve manifolds, and a streamlined fluidics path, to allow for improved aseptic sort setup. In addition, new software wizards make aseptic sort setup easy. Fluidics cart flow cell interrogation point laser beams nozzle Cuvette flow cell Hydrodynamic focusing within the flow cell forces particles through the cuvette in a single-file stream where laser light intercepts the stream at the sample interrogation point. The unique flow cell design permits particles to flow through the cuvette at a low velocity, allowing longer exposure to laser energy. This ensures optimal resolution and sensitivity even at high speed sort settings. After passing through the cuvette, the stream accelerates through the nozzle and droplets are formed for sorting. nozzle locking lever

The heart of a flow cytometer the gel-coupled cuvette flow cell The gel-coupled cuvette flow cell is where the sample is interrogated and measurements are performed. The BD FACSAria was the first cell sorter with a flow cell in true fixed alignment with the laser and gel coupled to the collection optics. Fixed alignment of the flow cell and laser helps to ensure that the laser is precisely focused on the sample stream and that each of the lasers can generate the greatest amount of signal. Fixed alignment minimizes startup time, improves experiment-to-experiment reproducibility, and enables automated daily quality control. Gel coupling to the objective lens improves collection efficiency and increases sensitivity and resolution needed for multicolor applications. This design enables multicolor sensitivity even at high-speed sort settings. Since particle interrogation occurs above the nozzle, insertion and removal of the nozzle can occur without realigning the optics or the fluid stream. The Fluidics Cart A separate fluidics cart supplies sheath and cleaning fluids and collects waste from the cytometer. The selfcontained fluidics cart supplies the air pressure and vacuum needed to achieve pressure from 5 to 75 psi to accommodate a variety of cell sorting applications. Air pressure is adjusted within BD FACSDiva software. The fluidics cart holds a 10-L stainless steel sheath tank, a 5-L stainless steel ethanol shutdown tank, a 10-L waste container, and three 5-L auxiliary cleaning fluid containers. The stainless steel sheath tank can be autoclaved for aseptic cleaning. The cart is typically positioned directly under or to the left of the cytometer. Cuvette flow cell and nozzle BD Accudrop Technology Patented BD Accudrop technology makes it easy to determine an accurate dropdelay value. Drop delay determination is now easier due to software automation. Software display of stream breakoff After the drop delay is calculated, the system automatically adjusts to maintain a constant breakoff, dubbed the Sweet Spot. If a clog is detected, the system stops the sort and protects the collection tubes.

SAMPLE TO SORT C Committed II Advance Aerosol management is engineered into the system. After leaving the nozzle, particles pass through the sort block where they are deflected into a collection device in the sort collection chamber. The sort block houses the high-voltage deflection plates used to deflect side streams during sorting. A novel deflection plate design fixes plates in position for more efficient and reproducible deflection. The aspirator and aspirator drawer are also housed in the sort block. The aspirator drawer keeps the sort collection tubes covered until sorting begins and automatically closes to protect sort collection tubes when the Sweet Spot is on and a clog is detected. The BD FACSAria is the fastest, most sensitive cell sorter that I have worked with, and the simple design of the new fluidics system makes sterile sort setup a breeze.

OLLECTION Aerosol management Engineered with aerosol management in mind, the BD FACSAria II features an enclosed pathway from the sample injection chamber to the sort collection tubes. For an added level of aerosol management, the BD TM Aerosol Management Option (AMO) evacuates the sort collection chamber and traps aerosolized particles during sorting. Sample injection chamber The sample injection chamber is where the sample is introduced into the flow cytometer. During acquisition, the chamber is pressurized, forcing the sample to the cuvette flow cell. Sample injection chamber temperature control and agitation are standard with the BD FACSAria II cell sorter. The BD FACSDiva software controls both sample agitation and temperature settings. After a sample tube is run, both the inside and outside of the sample injection tubing are flushed to minimize carryover. A variety of tube holders are provided, from 15-mL centrifuge tubes to 1.0-mL microtubes. New 35- and 50-micron sample line filters minimize clogging during a sort. Sort collection chamber The new universal mount in the sort collection chamber makes inserting the tube holders easier. This design is more robust and helps maintain aseptic conditions. Temperature control for both sort collection tubes and plates is available as an option. Sort collection chamber Nozzle selection and design An expanded set of nozzles lets users sort a wide range of particle sizes. Four nozzle sizes are supported: 70, 85, 100, and 130 microns. An improved nozzle insertion design offers tight registration for a secure fit. This means a reproducible drop profile after every insertion, allowing for reproducible instrument setup. Nozzles are readily accessible and easy to change. Software enhancements include a nozzlespecific sort setup feature that matches pressure settings to the nozzle in use.

OPTICS More II See Innovative designs for both the excitation optics and collection optics reduce excitation losses and dramatically improve collection efficiency. The optical design allows for the use of lower powered, air cooled, and solid state lasers for efficiency without sacrificing sensitivity or resolution. No special power or cooling is needed. Innovative optics design increases multicolor detection and efficiency. Excitation optics The excitation optics consist of lasers, fiber optic cables, beam-shaping prisms, and an achromatic focusing lens. Fiber optics precisely direct the laser light into beamshaping prisms that transmit the laser light into a focusing lens. The lens focuses the laser light into the gel-coupled cuvette flow cell. Since the optical pathway and the sample core stream are fixed, alignment is constant from day to day. Collection optics The collection optics are set up in octagon- and trigonshaped arrays that maximize signal detection from each laser. This is accomplished by transmitting the highest wavelengths to the first photomultiplier tube (PMT), and reflecting lower wavelengths to the next PMT through a series of longpass dichroic mirrors. Bandpass filters in front of each PMT allow fine-tuning of the spectral wavelengths that need to be collected. This design is based on the principle that light reflection is more efficient than light transmission. Emitted light travels to each PMT detector via reflection and is transmitted through only two pieces of glass to reach the detector. This greatly increases sensitivity and resolution for each color in a multicolor panel. FACSAria II SSC-A (x 1,000) 250 200 150 100 50 0-308 250 Aria II CD4 FITC Aria II CD4 APC Aria II CD4 Pacific Blue (x 1,000) SSC-A 250 200 150 100 50 10 2 10 3 10 4 10 5 0 10 2 10 3 10 4 10 5 0 10 2 10 3 10 4 10 5-1,328-228 CD4 FITC-A CD4 APC-A Pacific Blue-A Canto II CD4 FITC Canto II CD4 APC Canto II CD4 Pacific Blue (x 1,000) SSC-A 250 200 150 100 50 250 250 Platform comparison using CD4 Comparison of whole blood stained with single-color CD4 FITC, CD4 APC, and CD4 Pacific Blue and run on both the BD FACSAria II and BD FACSCanto II systems. The BD FACSAria II was set for high-speed sorting (70 psi and 90 khz) and both instruments were set up using BD Cytometer Setup and Tracking software. FACSCanto II SSC-A (x 1,000) 200 150 100 (x 1,000) SSC-A 200 150 100 (x 1,000) SSC-A 200 150 100 50 50 50-40 0 10 2 10 3 10 4 10 5 0 10 2 10 3 10 4 10 5 0 10 2 10 3 10 4 10 5-110 -39 FITC-A APC-A Pacific Blue-A

Excitation optics focus the 488-nm, 633-nm, and 405-nm laser beams nozzle stream cuvette flow cell fluorescence objective lens individual collection fibers Gel-coupled cuvette flow cell and fluorescence objective lens assembly The cuvette is gel coupled to the fluorescence objective lens to transmit the greatest amount of emitted light from the interrogation point to the collection optics. The lens focuses fluorescent light emitted at each of the laser interrogation points onto individual collection fibers. These fibers transfer the emitted light to the collection optics.

OPTICS Able II Perform For many users, the capability of an advanced cell sorter is defined by its flexibility, which in turn is defined by the number of parameters that can be detected simultaneously. To provide maximum flexibility, the BD FACSAria II cell sorter can be configured with up to four aircooled, solid state lasers and can detect up to 15 parameters simultaneously 13 fluorescent markers and two scatter parameters when fully equipped. Detects up to 15 parameters simultaneously for multicolor flexibility. A standard system is equipped with an octagon containing six PMTs that detect light from the 488-nm (blue) laser, and a trigon containing two PMTs that detect light from the 633-nm (red) laser. The third laser option adds an additional trigon containing two PMTs to detect light from the 405-nm (violet) or 375-nm (Near UV) lasers. Standard instruments can be configured with all four lasers. 375-nm Near UV Laser The 375-nm Near UV laser option is available to expand the range of application choices. Measuring only 19 7 7 cm, the fully-housed 375-nm laser fits in the small space immediately left of the flow cell. The laser produces a 10-mW focused beam to illuminate the cells in the flow cell without the aid of fiber optics. Intensity 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0-50 -40-30 -20-10 0 10 20 30 40 50 sample core stream 375-nm Near UV laser The top hat design of the 375-nm Near UV laser modifies the usual Gaussian beam (in red) that illuminates a sample at higher intensity in the middle of the beam (in blue) and lower intensity at the edges. The composite square beam illuminates the middle and edges of the sample core stream at the same intensity. The square beam almost triples the amount of light at the sample intercept. Guassian (red line) vs. Top Hat (blue line) illumination

Trigon and octagon detector arrays 450/20-A (x 1,000) 250 200 150 100 Mouse stem cell side population detection As a consequence of the even sample illumination, cells have a greatly improved coefficient of variation (CV). G B D F H 50 A 50 100 150 200 250 675 LP-A (x 1,000) E C Transmission pathways in an octagon

CONTROLS AND Easy II Handle The BD FACSAria II cell sorter places instrument setup, QC, sorting, and data management under the control of BD FACSDiva software so researchers can spend more time on experiments. Compatibility with other BD analyzers and sorters makes it easier to move from analysis to cell sorting. Digital electronics The BD FACSAria II cell sorter uses digital electronics to acquire data at rates up to 70,000 events per second for up to 8 parameters, with linear results over a broad dynamic range. Cytometer Setup and Tracking software Enhancements to BD FACSDiva software include a new Cytometer Setup and Tracking (CS&T) feature that automates flow cytometer setup, adjusts for instrument variability, and establishes baseline settings. Chances of operator error are reduced, and results are more consistent. The setup features let users define a configuration baseline and run a performance check. The software will then automatically set up the cytometer to this established baseline. To match the exact baseline, the CS&T software automatically adjusts for reproducible performance of the instrument. This ensures the greatest possible consistency from one day to the next, saves time, and improves reliability of experiment results. The software also allows for the creation of applicationspecific settings to allow for rapid performance of routine experiments in a more consistent manner. Tracking capabilities in the software measure a number of instrument settings and report on performance. Levey-Jennings plots help users understand instrument performance and identify maintenance issues. Fast startup to sort time u Turn on the sorter. v Start the fluidics. w Perform automated setup, QC, and drop delay optimization. x Optimize the sample. y Perform the sort.

ANALYSIS BD Cytometer Setup and Tracking software Outperforms analog from 0 to 100,000 events/sec Proccessed Events 90000 80000 70000 60000 50000 40000 30000 20000 10000 0 0 30000 60000 90000 120000 150000 180000 210000 Event Rate BD FACSAria II: uncompensated BD FACSAria II: compensated Dead time of 5.5 µsec BD FACSDiVa: compensated BD FACSAria II system acquisition rates

SERVICES Ready II Deliver BD Biosciences is fully committed to the success and satisfaction of its customers. The BD FACSAria II cell sorter is backed by a world-class service and support organization with unmatched flow cytometry experience. Since 1974, BD has innovated flow cytometry for optimal performance, ease of use, and improved workflow. This expertise is made available to BD FACSAria II customers through comprehensive training, applications and technical support, and expert field service. Training Hands-on training is included with each BD FACSAria II cell sorter. In addition, training courses are held at BD training centers worldwide. BD flow cytometry training courses combine theory and practice to provide participants with the skills and experience they need to take full advantage of the capabilities of the BD FACSAria II cell sorter. Technical application support BD Biosciences technical applications support specialists are available to provide field- or phone-based assistance and advice. Expert in a diverse array of topics, BD technical application specialists are well equipped to address customer needs in both instrument and applications support. Field service engineers When instrument installation or service is required, a BD Biosciences Technical Field Service Engineer can be dispatched to the customer site. BD Biosciences field service engineers are located across the world. On-site service and maintenance agreements are available to provide long-term support for the BD FACSAria II. Custom Services Mobilizing technology for research applications requires close collaboration. The Custom Technology Team (CTT) at BD Biosciences works with customers to provide solutions through custom reagents, panels, or assay protocols. Staffed by leading scientists with the breadth and depth of scientific and technical expertise, the CTT team will coordinate with researchers to study the problem at hand, make recommendations, and help implement the solutions. In this way, BD Biosciences technical know-how is translated into practical solutions that allow customers to focus on research. Special Order Research Products Instruments can be customized to meet customer requirements via the Special Order Research Products (SORP) programs.

Regional Offices bdbiosciences.com/offices Asia Pacific BD Singapore Tel 65.6861.0633 Fax 65.6860.1593 Australia/New Zealand Australia Toll Free: 1800 656 100 Tel 61.2.8875.7000 Fax 61.2.8875.7200 bd_anz@bd.com New Zealand Toll Free: 0800 572.468 Tel 64.9.574.2468 Fax 64.9.574.2469 bd_anz@bd.com Europe BD Biosciences Tel 32.2.400.98.95 Fax 32.2.401.70.94 help.biosciences@europe.bd.com Canada BD Biosciences Toll Free 888.259.0187 Tel 905.542.8028 Fax 888.229.9918 canada@bd.com Japan Nippon Becton Dickinson Toll Free 0120.8555.90 Tel 81.24.593.5405 Fax 81.24.593.5761 United States BD Biosciences Customer/Technical Service Toll Free 877.232.8995 Bioimaging Systems Fax 301.340.9775 Discovery Labware Fax 978.901.7490 Immunocytometry Systems Fax 800.325.9637 Pharmingen Fax 800.325.9637 bdbiosciences.com BD flow cytometers are Class I (1) laser products. 2008 Becton, Dickinson and Company. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in retrieval systems, or translated into any language or computer language, in any form or by any means: electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without prior written permission from BD Biosciences. The Alexa Fluor, Pacific Blue, and Cascade Blue dye antibody conjugates in this product are sold under license from Molecular Probes, Inc., for research use only, excluding use in combination with microarrays, or as analyte specific reagents. The Alexa Fluor dyes (except for Alexa Fluor 430), Pacific Blue dye, and Cascade Blue dye are covered by pending and issued patents. For research use only. Not for use in diagnostic or therapeutic procedures. Purchase does not include or carry any right to resell or transfer this product either as a stand-alone product or as a component of another product. Any use of this product other than the permitted use without the express written authorization of Becton Dickinson and Company is strictly prohibited. Product availability and prices are subject to change without notice. BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company. 2008 BD 23-9640-00 BD Biosciences 2350 Qume Drive San Jose, CA 95131 bdbiosciences.com