BD FACSCalibur. The flow cytometer for your routine cell analysis needs
|
|
|
- Marybeth Chapman
- 10 years ago
- Views:
Transcription
1 BD FACSCalibur The flow cytometer for your routine cell analysis needs
2
3 A system with a rich application basis and a modular approach that continues to meet evolving needs of cell analysis worldwide. The BD FACSCalibur platform offers a unique modular approach to flow cytometry and allows users to perform both cell analysis and cell sorting in an innovative single bench-top system. Designed with multicolor application support in mind, the BD FACSCalibur flow cytometer provides flexibility to support a wide variety of research and clinical applications. Engineered to meet evolving clinical and research requirements, the user-friendly BD FACSCalibur system can be easily upgraded to address emerging automation or sorting requirements in a laboratory. Walkway automation can be achieved by the BD FACS Loader option that handles tube-based assays or the BD High Throughput Sampler that handles assays in 96 or 384-well microtiter plates.* In addition, the BD FACSCalibur system can be upgraded to support cell sorting to allow for the isolation of a population of interest.* Built-in modularity and simple upgrades make the BD FACSCalibur an excellent long-term investment for today s cost conscious laboratories. The BD FACSCalibur system is compact and easy to use. It is complemented by a broad suite of intuitive software solutions to streamline analysis for a wide range of applications, including enumeration of lymphocyte subsets, stem cells, residual white blood cells, reticulocytes, DNA analysis,* immune function studies,* bead based immunoassays,* and multiplexed analysis of signal transduction* and phosphorylation targets.* Enabling fast, easy, and accurate results for routine applications with a versatile, modular design has made the BD FACSCalibur the automated benchtop cytometer of choice for cell analysis in research and clinical laboratories worldwide. *Some options and applications are for Research Use Only.
4 R E P R O D U C I B L E Performance and simplicity when it counts FL4 FL2 661/16 585/42 FL1 SSC 488/10 530/30 The BD FACSCalibur is a fully integrated multiparameter system that has the performance and sensitivity to ensure objective and reproducible results vital to laboratories worldwide. Optical path configuration Flow cytometry has evolved rapidly to incorporate the use of multiple fluorochromes to effectively identify and isolate subset populations in a single sample. This maximizes the information gained from limited samples and makes the assays more cost effective. The first system to provide standard multicolor analysis capabilities with the use of dual-laser technology, interbeam compensation, and an alignment free optical design, the BD FACSCalibur system ensures high sensitivity, minimal compensation, and maximum flexibility in choice of fluorochromes. This high performance system is a valued tool worldwide for routine cell analysis, assay development, verification, and identification of cellular populations of interest. FL3 670LP Blue laser 488 nm Red diode laser ~635 nm flow cell 488/10 FSC diode BD FACSCalibur optical path configuration Rare-event analysis A growing number of flow cytometry based assays depend on rare-event detection. For example, in the characterization of subpopulations of stem cells, millions of cells are analyzed to achieve a statistically significant sampling of the subset of interest. Advanced applications like this require a flow cytometer capable of high-speed analysis. The BD FACSCalibur system features a multiparameter triggering system that allows a user to accelerate the analysis by electronically eliminating events from onboard processing. Anti HLA-DR PerCP Gated Gated on R1 and on R1 R2and R2 Gated Gated on R1 and on R1 R2and R a a R4 R4 b b Anti HLA-DR PerCP R3 R A CD123 CD123 PE PE Anti HLA-DR PerCP Anti HLA-DR PerCP 10 3 R5 R B CD11c CD11c APC APC A Region R3 defines basophils and region R4 defines CD123 + DCs (0.14% of total). B Region R5 defines CD11c + DCs (0.21% of total). 4
5 R E S U L T S Dual-laser design for multicolor analysis The BD FACSCalibur dual-laser design provides the flexibility and sensitivity needed for multicolor analysis. Two lasers, an air-cooled argon laser and a red diode laser, are spatially separated for high sensitivity, minimal compensation, and maximum flexibility in fluorochrome selection. This maximizes the information obtained from limited samples and increases the cost-effectiveness of each assay. A fully integrated multiparameter system, the BD FACSCalibur system ensures objective and reproducible results, which are vital to today s laboratories. BD FACSCalibur optical bench Unique easy-to-use sorting technology (optional) The BD FACSCalibur cell sorting option allows users to identify and isolate a population of interest. Sorting on the BD FACSCalibur system occurs in a completely enclosed, aerosolfree environment for enhanced safety, which is especially important when processing biohazardous samples. The sorting process is designed to be straightforward. After the population of interest is gated, simply click Acquire to begin the sort. After the sample is acquired and cells pass through the laser, a unique catcher tube mechanism moves in and out of the sample core stream at a rate of roughly 300 times per second to capture designated cells and direct them to a collection tube or to an optional cell concentrator module for further processing. (The BD FACSCalibur cell sorting and cell concentrator options are for Research Use Only) BD FACSCalibur sorting mechanism 5
6 P R O D U C T I V I T Y Flexibility for sample introduction and enhanced productivity BD FACS Loader option The BD FACS Loader option available for the BD FACSCalibur system provides walkaway automation for routine applications. Featuring a removable 40-tube carousel, onboard mixing, and BD Worklist Manager software, the BD FACS Loader option offers superior flexibility to efficiently address the workflow demands of the busy laboratory. BD High Throughput Sampler (HTS) option The BD High Throughput Sampler (HTS) option provides flexible, easy-to-use automation. For those who prefer to work with multiwell plates, BD Biosciences offers the first walkaway sample introduction device for 96- and 384- well plates. The HTS option allows users to rapidly acquire samples with the BD FACSCalibur flow cytometer in a microtiter plate. As a modular option for new or existing BD FACSCalibur flow cytometers, the HTS option is designed to speed through a variety of microtiter plates in less than 15 minutes* and support a wide range of applications including the BD Cytometric Bead Array assay. The HTS option supports 96 U-, V-, and flat-bottom plates as well as 384-well microtiter plates. BD Plate Manager software allows you to create customized delivery protocols to be used repeatedly with user-defined mixing, wash, and analysis parameters. (The BD High Throughput Sampler option and BD Plate Manager are for Research Use Only) * Based on a 2-second sample acquisition. Efficient residual white blood cell enumeration The BD Leucocount system is the first automated, IVD-cleared product for monitoring leucoreduced blood products. Together with BD Trucount tubes and BD Leucocount process controls, the BD Leucocount system provides excellent accuracy, precision, and linearity. For highthroughput walkaway capability, the BD FACS Loader can also be added to your base BD FACSCalibur system. Mean Observed Leucocount WBC/µL Decision Point Area < < BD Leucocount kit The BD Leucocount system provides excellent accuracy, precision, and linearity at clinically significant levels of detection for RBC (red) and platelet (blue) samples. Expected WBC/µL 6
7 Immunophenotyping Characterizing cells at different stages of development through the use of fluorescent-labeled monoclonal antibodies against surface markers is one of the most common applications of flow cytometry. The BD FACSCalibur system provides multicolor capability in an easy-to-use system. Instrument setup is as easy as the push of a button and a click of the mouse. Efficient collection optics, coupled to the flow cell with an optical gel, permit the use of a low-powered, air-cooled argon laser and a red diode laser to ensure the high sensitivity required for analysis of low-density antigens. Accurate absolute counts with BD Trucount technology BD Trucount tubes make single-platform absolute counting easy no syringes, additional pipetting steps, or need to integrate data from another analyzer. Designed for use with clinical products such as BD Multitest and BD Tritest lymphocyte subsetting reagents, BD Leucocount rwbc assay kit, BD Trucount tubes bring precision to cell counts and improved productivity. For research applications, BD liquid counting beads are also available within the BD Cell Viability kit for quick estimations of cell cultures or bacterial concentrations. (The BD Cell Viability kit is for Research Use Only) CD4-PE Display of analysis for a sample prepared with BD Multitest reagents in a BD Trucount tube using the lyse/no-wash protocol in BD Multiset software CD3-FITC 7
8 D A T A M A N A G E M E N T Delivering results with a powerful, easy-to-use data management system The BD FACSCalibur system is appreciated for its userfriendly design, high sample throughput, improved workflow management through automation, and simple yet sophisticated software applications that enhance routine analyses. While performing any of a wide range of supported applications, the BD FACSCalibur system provides the tools to obtain results quickly, easily, and accurately. The ease-of-use of the BD FACSCalibur system is enhanced by the BD FACStation data management system that has become one of the most popular, user-friendly data management systems in flow cytometry. The BD FACStation system automates many software functions and delivers high-performance acquisition and analysis tools for creating plots, gating, statistical analysis, and reporting. The BD FACStation workstation takes advantage of the intuitive Mac environment by using simple pull-down menus and icons. It performs all the computing tasks required for fast, accurate results including instrument setup, as well as data collection, analysis, and management. A comprehensive quality assurance system BD Biosciences offers a complete family of products designed to ensure the highest quality clinical results from the BD FACSCalibur system. BD FACSComp software, in conjunction with BD Calibrite beads, provides a comprehensive system to set up the instrument, assess sensitivity, and set compensation for immunofluorescence applications. For clinical applications, BD Biosciences offers a wide variety of cellular controls to verify performance for immunophenotyping, reticulocyte analysis, stem cell enumeration, and rwbc applications. DNA Analysis The BD FACSCalibur system works together with BD DNA analysis quality control products to eliminate many of the variables associated with ploidy and cell-cycle analysis. The instrument s optical and fluidic design ensures that high-resolution DNA ploidy and S-phase determinations are easy to achieve. Electronic doublet discrimination, using the area and width of the fluorescence pulse, allows for the removal of artifacts doublets and aggregates from the analysis. High-resolution electronics and linearity ensure accurate results. To ensure optimal performance, BD DNA QC products, including fixed cells and fluorescent particles, can be used for setup, verification of the doublet discrimination module, and monitoring daily operation. (BD DNA Analysis products are for Research Use Only) FL2-Area R FL2-Width Counts FL2-Area DNA analysis Pulse processing is a powerful tool used in the discrimination of doublets for optimal DNA analysis. 8
9 0 Sample Name: CAP Sample ID: Case Number: FI-09 Fl1 CD3/CD16+56/CD45/CD19 TruC Reagent Lot ID: Events Acquired: Data Set [ 1 ] Data File: Fl Abs Cnt Bd Lot ID: Attr Def File: 3/16+56/45/19 MLT/TruC v2.1 File ID: 70395AA3-3D7C-11DD- BD CB10 Beads per Pellet: Lymph Events Bead Events CD3+ %Lymph BDIS HLA-B27 Laboratory Report CD3+ Abs Cnt CD %Lymph CD ABS Cnt CD19+ %Lymph CD19+ Abs Cnt SSC-H CD16+56-PE SSC-H Director: Viki Mosiman Cytometer: FACSCalibur (E0073) CD45+ Abs Cnt 1898 CD45-PerCP CD3-FITC CD3-FITC Operator: Administrator Software: HLA-B27& v4.0 Sample Name: Sample ID: Date Acquired: Date Analyzed: Data File Name: Lab Report Name: CAP B Aug-08 16:51:26 Thu, Dec 11, :39 PM B B lab CD19- APC Bead Lot ID: Reagent Lot ID: 02451/ :147 CD16+56-PE Events Acquired: Gated Events: Preset FL1 Marker: Conclusion: Sample FL1 Median: 169 HLA-B27 positive sample Multi-tube QC Lymphosum: 97.9 CD3 % Lymph Difference: 0 CD3 Abs Cnt Range: T Helper/Suppressor Ratio: 2.08 SSC-H FL2-H (CD3) Director: Operator: Lorielei Administrator BDIS MultiSET Lab Report Software: Cytometer: MultiSET V2.2 (file-based analysis) Sample Name: CAP Date Acquired: 18-Jun-08 14:20:00 Sample ID: Fl-09 Date Analyzed: Thu, Dec 11, 2008 Case Number: Fl1 Ref. Range Type: BD FSC-H FSC-H Panel Name: 4 Color TBNK + TruC 90 CD3/CD8/CD45/CD4 TruC Data Set [ 1 ] Data File: Fl Reagent Lot ID: Events Acquired: Abs Cnt Bd Lot ID: Attr Def File: 3/8/45/4 MLT/TruC v2.0 Counts File ID: 4EF D7C-11DD- BD CB10 Lymph Events Bead Events Beads per Pellet: CD3+ %Lymph FL1-H (HLA-B27) CD3+ Abs Cnt CD3+CD8+ %Lymph CD3+CD8+ ABS Cnt SSC-H CD8-PE SSC-H Comments: CD3+CD4+ %Lymph CD3+CD4+ Abs Cnt 906 CD3+CD4+CD8+ % Lymph 0.07 CD3+CD4+CD8+ Abs Cnt 1 CD45-PerCP CD3-FITC CD3-FITC CD45+ Abs Cnt 1914 T H/S Ratio 2.08 CD4-APC CD8-PE Beads Sample Wash Analyze by flow cytometry Concentration D F PE MFI C NIR A Detector antibodies B E Red MFI Concentration (pg/ml) BD Cytometric Bead Array assays The BD FACSCalibur flow cytometer can be used to acquire data from BD Cytometric Bead Array (CBA) multiplexed assays. These assays are powerful, flexible tools that simultaneously quantify multiple cytokine, chemokine, immunoglobulin, or cell signaling targets from a single sample. Choose from preconfigured kits for maximum convenience in screening routine panels of Th1/Th2 or inflammatory cytokines and chemokines, or build your own multiplex assay using the open and configurable BD CBA Flex Set format. For all of their power, BD CBA assays are fast and remarkably easy to use. Pre-optimized protocols and one-step detection reagents minimize hands-on time and maximize reproducibility. (BD Cytometric Bead Array assays are for Research Use Only) 9
10 S E R V I C E A N D S U P P O R T Service and Support BD Biosciences instruments and reagents are backed by a world-class service and support organization with unmatched flow cytometry experience. For over twenty-five years, BD has actively worked with researchers to develop tools that help improve workflow, ease of use, and performance. This in-depth knowledge and experience is available to customers through comprehensive training, application and technical support, and expert field service. Training Held at BD training centers worldwide, BD Biosciences flow cytometry training courses combine theory and hands-on practice to provide participants with the skills and experience they need to take full advantage of the capabilities of their instrument. Technical applications support BD Biosciences technical applications support specialists are available to provide field- or phone-based assistance and advice. Expert in a diverse array of topics, BD technical application specialists are well equipped to address customer needs in both instrument and applications support. Field service engineers BD Biosciences field service engineers are located across the world. When instrument installation or service is required, a BD Biosciences technical field service engineer can be dispatched to your site. On-site service and maintenance agreements are available to provide long-term support. 10
11
12 Regional Offices bdbiosciences.com/offices Asia Pacific BD Singapore Tel Fax Australia/New Zealand Australia Toll Free: Tel Fax New Zealand Toll Free: Tel Fax Europe BD Biosciences Tel Fax Canada BD Biosciences Toll Free Tel Fax Japan Nippon Becton Dickinson Toll Free Tel Fax Latin America/Caribbean BD Biosciences Toll Free Tel Fax United States BD Biosciences bdbiosciences.com Customer/Technical Service Toll Free Bioimaging Systems Fax Discovery Labware Fax Immunocytometry Systems Fax Pharmingen Fax BD flow cytometers are Class I (1) laser products Becton, Dickinson and Company. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in retrieval systems, or translated into any language or computer language, in any form or by any means: electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without prior written permission from BD Biosciences. Unless otherwise noted, all products are for In Vitro Diagnostic Use. Purchase does not include or carry any right to resell or transfer this product either as a stand-alone product or as a component of another product. Any use of this product other than the permitted use without the express written authorization of Becton Dickinson and Company is strictly prohibited. Product availability and prices are subject to change without notice. BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company BD BD Biosciences 2350 Qume Drive San Jose, CA bdbiosciences.com
BD FACSCalibur Flow Cytometer
BD FACSCalibur Flow Cytometer The Automated, Multicolor Flow Cytometry System A Complete System for Today s Laboratory BD Biosciences Clontech Discovery Labware Immunocytometry Systems Pharmingen The Gold
BD FACSComp Software Tutorial
BD FACSComp Software Tutorial This tutorial guides you through a BD FACSComp software lyse/no-wash assay setup run. If you are already familiar with previous versions of BD FACSComp software on Mac OS
FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data. Monisha Sundarrajan, PhD BD Biosciences
FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data Monisha Sundarrajan, PhD BD Biosciences 23 13795 00 Agenda Introduction Overview of BD CBA bead based immunoassays FCAP
BD FACSCanto Flow Cytometer. Efficient Easy Powerful
BD FACSCanto Flow Cytometer Efficient Easy Powerful The BD FACSCanto System: Optimal Workflow and Time Management Automated compensation algorithms with optional off-line compensation, streamlined sample
Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T
Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom Cat. Reference: STP-25T Reagent provided:: 25 Stepcount tubes for 25 test INTENDED USE. Immunostep
Clinical and Laboratory Practices Workshops. Helping to improve laboratory skills and the quality of care in resource-limited settings
Clinical and Laboratory Practices Workshops Helping to improve laboratory skills and the quality of care in resource-limited settings BD is committed to collaborating with governmental and non-governmental
BD FACSVerse. Simply brilliant
BD FACSVerse Simply brilliant BD FACSVerse: Simply Brilliant The BD FACSVerse flow cytometer was engineered from the ground up to offer remarkable performance, flexibility, and ease of operation for research
Introduction to Flow Cytometry
Introduction to Flow Cytometry presented by: Flow Cytometry y Core Facility Biomedical Instrumentation Center Uniformed Services University Topics Covered in this Lecture What is flow cytometry? Flow cytometer
Let the BD FACSAria II accompany your best performance ever
Let the BD FACSAria II accompany your best performance ever Meet the new BD FACSAria II high-speed, fixed-alignment cuvette cell sorter. The first generation BD FACSAria system brought the complex world
Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction
Application Note 10 Measurement of Cell Recovery After Sorting with a Catcher-Tube-Based Cell Sorter Introduction In many experiments using sorted cells, it is important to be able to count the number
Introduction to Flow Cytometry
Outline Introduction to Flow Cytometry Basic Concept of Flow Cytometry Introduction to Instrument Subsystems Daisy Kuo Assistant Product Manager E-mail: [email protected] BDBiosciences Application Examples
Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer
Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer Presented by Clare Rogers, MS Senior Marketing Applications Specialist BD Biosciences 23-13660-00 Webinar Overview Multicolor
Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service
Introduction into Flow Cytometry Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service How does a FACS look like? FACSCalibur FACScan What is Flow Cytometry?
LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry
LOAD & GO and make flow cytometry simplicity itself the full spectrum of Flow Cytometry Introducing Aquios CL...the first true LOAD & GO flow cytometer What would it mean for your laboratory s productivity
Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and
Using BD FACSDiva CST To Evaluate Cytometer Performance, Create Custom Assay Settings and Implement Cross-Instrument and Cross-Site Standardization of Assays PART 2 Alan M. Stall Director, Advanced Cytometry
APPLICATION INFORMATION
DRAFT: Rev. D A-2045A APPLICATION INFORMATION Flow Cytometry 3-COLOR COMPENSATION Raquel Cabana,* Mark Cheetham, Jay Enten, Yong Song, Michael Thomas,* and Brendan S. Yee Beckman Coulter, Inc., Miami FL
Welcome to More Choice BD Analyte Specific Reagent (ASR) Catalog
Welcome to More Choice BD Analyte Specific Reagent (ASR) Catalog 3 rd Edition Contents ASR Cell Lineage 3 15 Marker 16 25 Flow cytometry allows you to analyze multiple parameters simultaneously and by
Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer
Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer Contents 2 Thresholds 2 Setting the Threshold When analyzing small particles, defined as particles smaller than 3.0 µm, on the
Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking
Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking Mark KuKuruga Senior Technical Applications Specialist BD Biosciences 23-14462-00 Outline
Introduction to flow cytometry
Introduction to flow cytometry Flow cytometry is a popular laser-based technology. Discover more with our introduction to flow cytometry. Flow cytometry is now a widely used method for analyzing the expression
The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee
January, 1999 From: To: Subject: The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee NIAID DAIDS Flow Cytometry Laboratories Comparison study information for labs wishing to switch
Preparing BD Systems for Data Migration. Summary of the Upgrade Process on page 6. Copying User Data Files onto an Upgraded System on page 7
Windows 7 Upgrade Instructions 8/2014 Preparing BD Systems for Data Migration Contents Overview Backing Up Your Data on page 2 Summary of the Upgrade Process on page 6 Copying User Data Files onto an Upgraded
Cytell Cell Imaging System
Cytell Cell Imaging System Simplify your cell analysis and start changing tomorrow today www.gelifesciences.com/cytell The Cytell Cell Imaging System is an intuitive cell analysis instrument that streamlines
BD Trucount Tubes IVD
02/2015 23-3483-07 IVD BD Trucount Tubes For determining absolute counts of leucocytes in blood 25 Tubes Catalog No. 340334 BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company.
powerful. Intuitive. Customizable. The new star of benchtop flow cytometry
powerful. Intuitive. Customizable. The new star of benchtop flow cytometry About ACEA Established in 2002, ACEA Biosciences, Inc. develops cutting-edge cell analysis platforms for life science research.
Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers
An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers BD Biosciences, San Jose, CA Contents 2 Introduction to compensation 5 Tips for setting up compensation 10 Tools for easy,
123count ebeads Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.
Page 1 of 1 Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use. Normal human peripheral blood was stained with Anti- Human CD45 PE (cat.
Immunophenotyping peripheral blood cells
IMMUNOPHENOTYPING Attune Accoustic Focusing Cytometer Immunophenotyping peripheral blood cells A no-lyse, no-wash, no cell loss method for immunophenotyping nucleated peripheral blood cells using the Attune
CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping
CyFlow SL Healthcare Immunology Portable FCM System for 3-colour Immunophenotyping 01 COMPANY Flow Cytometry made in Germany New sophisticated applications and increasing requirements for reliable results
CyAn : 11 Parameter Desktop Flow Cytometer
CyAn : 11 Parameter Desktop Flow Cytometer Cyan ADP 3 excitation lines 488nm, 635nm, and UV or violet 11 simultaneous parameters FSC, SSC, and 7-9 colors with simultaneous width, peak, area, and log on
BD FACSAria Flow Cytometer. The first high-speed sorter with a fixed-alignment cuvette flow cell from BD Biosciences
BD FACSAria Flow Cytometer The first high-speed sorter with a fixed-alignment cuvette flow cell from BD Biosciences Header From Pioneers to Revolutionaries in Flow Cytometry Instrumentation BD Biosciences
Instrument Characterization and Performance Tracking for Digital Flow Cytometers
Instrument Characterization and Performance Tracking for Digital Flow Cytometers BD Biosciences Cytometer Set-up & Tracking (CS&T) System For Research Use Only. Not for use in diagnostic or therapeutic
Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation...
Immunophenotyping Flow Cytometry Tutorial Contents Experimental Requirements...1 Data Storage...2 Voltage Adjustments...3 Compensation...5 Experimental Requirements For immunophenotyping with FITC and
Uses of Flow Cytometry
Uses of Flow Cytometry 1. Multicolour analysis... 2 2. Cell Cycle and Proliferation... 3 a. Analysis of Cellular DNA Content... 4 b. Cell Proliferation Assays... 5 3. Immunology... 6 4. Apoptosis... 7
Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit
2 Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit Presented by Ellen Meinelt, MS MLS(ASCP) CM, Technical Applications Specialist and Calin Yuan, Product Course Developer,
BD FACSAria Flow Cytometer. BD Biosciences Clontech Discovery Labware Immunocytometry Systems Pharmingen
BD FACSAria Flow Cytometer The first high-speed sorter with a fixed-alignment cuvette flow cell from BD Biosciences BD Biosciences Clontech Discovery Labware Immunocytometry Systems Pharmingen From Pioneers
Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose
Selecting Reagents for Multicolor Flow Cytometry Holden Maecker and Joe Trotter BD Biosciences, San Jose Contents 1 The basics: Know your instrument 2 Fluorochromes: Go for the bright 3 Colors and specificities:
CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE
CELL CYCLE BASICS Analysis of a population of cells replication state can be achieved by fluorescence labeling of the nuclei of cells in suspension and then analyzing the fluorescence properties of each
Getting Started with BD FACSDiva Software
Getting Started with BD FACSDiva Software For In Vitro Diagnostic Use bdbiosciences.com Part No. 642213 Rev. A June 2007 BD Biosciences 2350 Qume Drive San Jose, CA 95131-1807 USA Tel (877) 232-8995 Fax
Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract
arch 212 Standardizing Application Setup Across ultiple Flow Cytometers Using BD FACSDiva Version 6 Ellen einelt, ervi Reunanen, ark Edinger, aria Jaimes, Alan Stall, Dennis Sasaki, Joe Trotter Contents
Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.
Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy. At the end of this session, the participant will be able to: 1. Describe the components of a flow cytometer 2. Describe the gating
No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer
APPLICATION NOTE Attune NxT Flow Cytometer No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer Introduction Standard methods for isolating and detecting leukocytes
BD FACSCalibur Instructions For Use
BD FACSCalibur Instructions For Use IVD For In Vitro Diagnostic Use bdbiosciences.com Part No. 643271 Rev. A November 2007 BD Biosciences San Jose, CA 95131-1807 USA Tel (877) 232-8995 Fax (800) 325-9637
Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement
What is Flow Cytometry? Flow Cytometry Basic Principle and Applications BD Biosciences Daisy Kuo ([email protected]) Flow = Fluid Cyto = Cell Metry = Measurement A variety of measurements are made on cells,
Boundary-breaking acoustic focusing cytometry
Boundary-breaking acoustic focusing cytometry Introducing the Attune NxT Acoustic Focusing Cytometer a high-performance system that s flexible enough for any lab One of the main projects in my laboratory
BD Pathway Bioimaging Systems
BD Pathway Bioimaging Systems Cellular Imaging for High-Content Analysis Delivering industry-leading bioimaging, BD Pathway high-content cell analyzers combine superior image quality, flexible image capture,
Standardization, Calibration and Quality Control
Standardization, Calibration and Quality Control Ian Storie Flow cytometry has become an essential tool in the research and clinical diagnostic laboratory. The range of available flow-based diagnostic
FACSCalibur System User s Guide
11-10823-02 Rev. A FACSCalibur System User s Guide 02-61760-02 August, 1996 Becton Dickinson Immunocytometry Systems 2350 Qume Drive San Jose, CA 95131-1807 Ordering Information (800) 223-8226 Customer
Introduction to Flow Cytometry:
Introduction to Flow Cytometry: A Learning Guide Manual Part Number: 11-11032-01 April, 2000 BD Biosciences 2350 Qume Drive San Jose, CA 95131-1807 1-800-448-2347 Introduction to Flow Cytometry: A Learning
Laboratory Procedure Manual
Laboratory Procedure Manual Analyte: Matrix: Method: CD4+ T-Lymphocytes and CD8 T Cells Whole Blood TriCount Method Method No.: Revised: as performed by: Lee Lam or Marjorie Hubbard HIV Immunology and
CyTOF2. Mass cytometry system. Unveil new cell types and function with high-parameter protein detection
CyTOF2 Mass cytometry system Unveil new cell types and function with high-parameter protein detection DISCOVER MORE. IMAGINE MORE. MASS CYTOMETRY. THE FUTURE OF CYTOMETRY TODAY. Mass cytometry resolves
Automation of Cell Staining Technical Information Bulletin
Automation of Cell Staining Technical Information Bulletin Automation of Cell Staining Using the Biomek 4000 Laboratory Automation Workstation Amy N. Yoder, Sr. Development Scientist and Li Liu, Sr. Development
These particles have something in common
These particles have something in common Blood cells Chromosomes Algae Protozoa Certain parameters of these particles can be measured with a flow cytometer Which parameters can be measured? the relative
History of Innovation
1 History of Innovation Only Immucor consistently delivers the next-generation of blood bank automation to labs worldwide ABS HV Galileo NEO 1998 1999 2004 2007 2010 ABS2000 ABS Precis Echo 2 Innovation
Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement
Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement Andreas Spittler, MD, Associate Professor for Pathophysiology, Medical University
Bacterial Detection and Live/Dead Discrimination by Flow Cytometry
A P P L I C A T I O N N O T E Bacterial Detection and Live/Dead Discrimination by Flow Cytometry M I C R O B I A L C Y T O M E T R Y BD FACSCalibur, BD FACSort Flow Cytometers Introduction Accurate determination
Services. Contract. Optimize. Results. Instrument. Guidance. Reagent
Services Instrument Guidance Results Access Expertise Streamline Reagent Optimize Contract Keeping your lab in a perpetual state of the art For more than 30 years, BD Biosciences has delivered flow cytometry
CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE
CELL CYCLE BASICS Analysis of a population of cells replication state can be achieved by fluorescence labeling of the nuclei of cells in suspension and then analyzing the fluorescence properties of each
LEGENDplex Data Analysis Software
LEGENDplex Data Analysis Software Version 7.0 User Guide Copyright 2013-2014 VigeneTech. All rights reserved. Contents Introduction... 1 Lesson 1 - The Workspace... 2 Lesson 2 Quantitative Wizard... 3
Standard Operating Procedure
1.0 Purpose: 1.1 The characterisation of of main leukocyte subsets in peripheral blood cells from mice by flow cytometry. Reliable values of frequencies of leukocyte clusters are very much dependent on
Science is hard. Flow cytometry should be easy.
Science is hard. Flow cytometry should be easy. TABLE OF CONTENTS 1 INTRODUCTION TO BD ACCURI C6 SOFTWARE... 1 1.1 Starting BD Accuri C6 Software... 1 1.2 BD Accuri C6 Software Workspace... 2 1.3 Opening
Information security guidelines
Information security guidelines BD Biosciences workstations 8/2014 This document includes the following topics: About this guide (page 2) Software policies (page 3) Virus protection setup and operation
Cell Cycle Tutorial. Contents
Cell Cycle Tutorial Contents Experimental Requirements...2 DNA Dyes...2 Protocols...3 PI Parameter & Analysis Setup...4 PI Voltage Adjustments...6 7-AAD Parameter Setup...6 To-Pro3 Parameter Setup...6
CyFlow Space Your flexible flow cytometer
Your flexible flow cytometer www.sysmex-partec.com its flexibility gives you the space you need for your work Analysing cells and particles, be it from blood, plasma, tissue, plants, cell cultures or other
CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles
CyFlow SL Microbiology Detection and Analysis of Microorganisms and Small Particles 01 COMPANY Flow Cytometry made in Germany New sophisticated applications and increasing requirements for reliable results
BD CellQuest Pro Software Analysis Tutorial
BD CellQuest Pro Analysis Tutorial This tutorial guides you through an analysis example using BD CellQuest Pro software. If you are already familiar with BD CellQuest Pro software on Mac OS 9, refer to
BD FACSCanto II Instructions For Use
BD FACSCanto II Instructions For Use IVD For In Vitro Diagnostic Use bdbiosciences.com Part No. 642239 Rev. A June 2007 BD Biosciences 2350 Qume Drive San Jose, CA 95131-1807 USA Tel (877) 232-8995 Fax
Compensation Controls Data Visualization Panel Development Gating Quantum Dots
Compensation Controls Data Visualization Panel Development Gating Quantum Dots FITC Single Stain Control FITC PE Argon Laser FL1 FL2 450 500 550 600 FITC Compensation Control Unwanted signal detected in
Cell Discovery 360: Explore more possibilities.
Cell Discovery 360: Explore more possibilities. Flexible solutions for the BioPharma laboratory Blood Banking Capillary Electrophoresis Centrifugation Flow Cytometry Genomics Lab Automation Lab Tools Particle
Application Note. Cell Cycle and DNA Content Analysis Using the BD Cycletest Assay on the BD FACSVerse System. Summary
Cell Cycle and DNA Content Analysis Using the BD Cycletest Assay on the BD FACSVerse System Yibing Wang, Catherine McIntyre, and Dev Mittar BD Biosciences, San Jose Contents 1 Summary 2 Introduction 3
HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE
POWERFUL. INTUITIVE. CUSTOMIZABLE. HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE ABOUT ACEA Established in 2002, ACEA Biosciences, Inc. develops cutting-edge cell analysis platforms for life science research.
Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides
The Integrated Lab Connected Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides NOVA View Reduces costs with automation efficiencies
Setting up and calibration of a flow cytometer for multicolor immunophenotyping
Journal of Biological Regulators and Homeostatic Agents Setting up and calibration of a flow cytometer for multicolor immunophenotyping J. KRAAN 1, J.W. GRATAMA 1, M. KEENEY 2, J.L. D HAUTCOURT 3 1 Department
Institut für Experimentelle Immunologie und Bildgebung
Page 1 von 6 Starting Up the System Start up the computer, start Windows and log in as IMCES_user start BD FACSDiva software with your Groupname Turn on the cytometer main power Wait a moment and Check
BD FACSCanto II Flow Cytometer Reference Manual
BD FACSCanto II Flow Cytometer Reference Manual For In Vitro Diagnostic Use bdbiosciences.com Part No. 640806 Rev. A May 2006 BD Biosciences 2350 Qume Drive San Jose, CA 95131-1807 USA Tel (877) 232-8995
MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:
INTRODUCTION Flow Cytometry involves the use of a beam of laser light projected through a liquid stream that contains cells, or other particles, which when struck by the focused light give out signals
BD CellQuest Pro Software User s Guide
BD CellQuest Pro Software User s Guide http://www.bdbiosciences.com/ Part No. 349226 Rev. A July 2002 BD Biosciences 2350 Qume Drive San Jose, CA 95131-1807 USA Tel (877) 232-8995 Fax (408) 954-2347 Asia
COMPENSATION MIT Flow Cytometry Core Facility
COMPENSATION MIT Flow Cytometry Core Facility Why do we need compensation? 1) Because the long emission spectrum tail of dyes causes overlap like with the fluorophores FITC and PE. 2) For sensitivity reasons,
Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility
Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility The mention of commercial products, their sources, or their use in connection
Meso Scale Discovery. WINDOWS is a registered trademark of Microsoft Corporation
Meso Scale Discovery M S D M S D Meso Scale Discovery, a division of Meso Scale Diagnostics, LLC. (MSD) 9238 Gaither Rd, Gaithersburg, MD 20877 Phone: 240.631.2522 Fax: 240.632.2219 email: [email protected]
BD Influx. A high-speed cell sorter that adapts to your way of thinking
BD Influx A high-speed cell sorter that adapts to your way of thinking The BD Influx cell sorter adapts to your way of thinking The BD Influx cell sorter is a flexible flow cytometry platform that easily
BD Cytometric Bead Array (CBA) Mouse/Rat Soluble Protein Master Buffer Kit
BD Cytometric Bead Array (CBA) Mouse/Rat Soluble Protein Master Buffer Kit Instruction Manual Catalog No. 558266 (100 Tests) Catalog No. 558267 (500 Tests) ii BD CBA Mouse/Rat Soluble Protein Master Buffer
BD FC Beads 8-Color Kit for BD OneFlow Assays
BD FC Beads 8-Color Kit for BD OneFlow Assays 7/2014 23-15785-00 IVD 5 tests per kit Catalog No. 658621 BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company. 2014 BD Becton,
Principles of Flowcytometry
Objectives Introduction to Cell Markers: Principles of Flowcytometry Michelle Petrasich NZIMLS Scientific Meeting August 24, 2010, Paihia What are cell markers How do we detect them Production of Monoclonal
Automated Nucleic Acid Extraction WorkStation Faster, cleaner,
Automated Nucleic Acid Extraction WorkStation Faster, cleaner, more consistent nucleic acid extraction The Thermo Scientific Automated Nucleic Acid Extraction WorkStation is a turn-key solution that provides
ArC Amine Reactive Compensation Bead Kit
ArC Amine Reactive Compensation Bead Kit Catalog no. A1346 Table 1. Contents and storage information. Material Amount Composition Storage Stability ArC reactive beads (Component A) ArC negative beads (Component
Spherotech, Inc. 27845 Irma Lee Circle, Unit 101, Lake Forest, Illinois 60045 1
78 Irma Lee Circle, Unit 0, Lake Forest, Illinois 00 SPHERO TM Technical Note STN- Rev B 008 DETERMINING PMT LINEARITY IN FLOW CYTOMETERS USING THE SPHERO TM PMT QUALITY CONTROL EXCEL TEMPLATE Introduction
Echo. Compact Immunohematology automation. Echo is designed to bring the benefits of automation to labs of all sizes and volumes.
Echo Compact Immunohematology automation Echo is designed to bring the benefits of automation to labs of all sizes and volumes. Transfuse Transplant Transform a life Echo Instrument Map A D B C E I want
Establishing Optimum Baseline PMT Gains to Maximize Resolution on BD Biosciences Digital Flow Cytometers
A P P L I C A T I O N N O T E BD Digital Flow Cytometers Establishing Optimum Baseline PMT Gains to Maximize Resolution on BD Biosciences Digital Flow Cytometers Specific Aims This application note describes
Flow cytometric analysis of stem cells derived from umbilical cord blood CD34+/CD45+ enumeration and viability
Flow cytometric analysis of stem cells derived from umbilical cord blood CD34+/CD45+ enumeration and viability Doretha Thompson Dissertation in fulfillment of the requirements for the degree Magister Scientiae
Absolute counting using flow cytometry. Bright Count Microspheres
Absolute counting using flow cytometry Single-platform system for absolute counts I PRODUCT MANUAL [REF] IQP-391 [REF] IQP-392 s 50 tests s 100 tests [IVD] In Vitro Diagnostic medical device IQ Products
BD StemFlow Human Pluripotent Stem Cell Sorting and Analysis Kit
BD StemFlow Human Pluripotent Stem Cell Sorting and Analysis Kit Instruction Manual Catalog No. 560461 ii Human Pluripotent Stem Cell Sorting and Analysis Kit 2009, Becton, Dickinson and Company. All rights
AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs
AB SCIEX TOF/TOF 4800 PLUS SYSTEM Cost effective flexibility for your core needs AB SCIEX TOF/TOF 4800 PLUS SYSTEM It s just what you expect from the industry leader. The AB SCIEX 4800 Plus MALDI TOF/TOF
Flow Cytometry A Basic Overview
Flow Cytometry A Basic Overview Overview Flow cytometry is a powerful technology for investigating many aspects of cell biology and for isolating cells of interest. Flow cytometry utilizes highly focused,
The GeneAmp PCR System 9700. Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700
The GeneAmp PCR System 9700 Results you can trust. A PCR platform you can grow with. GeneAmp PCR System 9700 The GeneAmp PCR System 9700 fits your lab bench, your applications and your budget. The GeneAmp
Instructions for Use. CyAn ADP. High-speed Analyzer. Summit 4.3. 0000050G June 2008. Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835
Instructions for Use CyAn ADP High-speed Analyzer Summit 4.3 0000050G June 2008 Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835 Overview Summit software is a Windows based application that
Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs
Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex
