REPLACE ROOFING DENVER CENTRAL LIBRARY PHASE I CITY & COUNTY OF DENVER DENVER, COLORADO



Similar documents
Sheet A-1 KEY SHEET A-1. Football Roof Plan SHEET A-2 SHEET A-3 SHEET A-4. LaCross Roof Plan. Soccor 2 Roof Plan 88' 45' 87' 46' 45' 45' 10' 3' 25'

Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ 36.

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Roof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, RBA Project No

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS


NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Clear Fork Valley Local School District. Roofing Repairs Spring/Summer 2015

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

How To Repair A Boat Landing Deck With A Boat Bed

Indefinite Quantity Unit Price Schedule

Ver. 2. Guide to. Inspecting Residential Brick Veneer

Roof Inspection and Evaluation

TARRANT COUNTY DETAIL STANDARDS

CERVANTES COMMUNITY CENTER RE-ROOFING NEW MEXICO STATE UNIVERSITY

Roof Inspection Report 3840 Greenway Circle, Lawrence Kansas, Sauer-Danfoss Building

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

CITYPLEX TOWERS BOILER INSTALLATION ORU RFP-1138

SECTION ROOFING TILE

Delaney-Vogel School

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Classic Products, Inc. ClickLock Standing Seam Installation Manual

A0 SHEET 1 OF LOCUST STREET FRANKFORT, KANSAS FRANKFORT, KANSAS ROOF REPAIR OF THE 400 LOCUST STREET

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

MINNEAPOLIS MARKET STREAM PRIVATE DATA CENTER CHASKA, MINNESOTA Ross Avenue, Suite 2800 Dallas, Texas 75201

CHAPTER 7: Building Systems ROOFING SYSTEMS

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

Superform Products Ltd.

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

INSTALLATION OF A BAY WINDOW

WISCONSIN HOUSING AND ECONOMIC DEVELOPMENT AUTHORITY

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

UL Online Certifications Directory

Mark Cramer Inspection Services, Inc.

AMERICAN GOTHIC PLAYHOUSE

SEAMS SEAMING USING SEAM TAPE

Asphalt Shingle Application Requirements

CONTINENTAL MATERIALS, INC. ALL-WEATHER APP INSTALLATION GUIDELINES

REQUEST FOR PROPOSALS

SECTION PVC SINGLE PLY ROOFING

EPDM System Repair and Cleaning

Larry Haight's Residential Roofing Co, Inc NE 95th Street Redmond, Washington Phone: (425) Fax: (425)

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

Roof Inspection. Summary Report

Maintenance & Inspection Guide

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC.

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Waterproof Rooftop Balconies & Decks. Or How To Keep Your Ceiling Dry When People Walk On Your Roof

STREAM PRIVATE DATA CENTER SAN ANTONIO MARKET WESTOVER HILLS Ross Avenue, Suite 2800 Dallas, Texas

FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

PERIMETER FLASHING. Table of Contents

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

University of California - Santa Barbara West Campus Point Faculty Housing

ROOFS - Guidance for Repair, Maintenance and Replacement

Final inspections are completed by site visit only. Access to fenced yards shall be planned.


HISTORIC PRESERVATION COMMISSION ADMINISTRATIVE APPROVAL ISSUED JULY - SEPTEMBER 2014 DATE PROJECT ADDRESS PROJECT DESCRIPTION

STREAM PRIVATE DATA CENTER

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

MUNICODE SERVICES LTD.

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Residential Roofing Guide

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE

PETERSONS WATERFRONT CONDOMINIUMS

ISO Types 1-6: Construction Code Descriptions

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

DISTRICT OF BARRIERE REQUEST FOR PROPOSAL

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

ROOF ASSEMBLIES CHAPTER 9

Epdm Flat Roofing Systems

February 4, Estimate

Roofing and Sealants. Contents. Section Single-ply membrane splicing cement Most frequently used types of roofing

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

SECTION STANDING SEAM METAL ROOFING

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

THERMOPLASTIC MEMBRANE (PVC) ROOFING Added 11/ Thermal and Moisture Protection

Firestone RubberGard The EPDM reference

DIVISION 7 - THERMAL AND MOISTURE PROTECTION

Point Auditorium Design Narrative PROJECT NAME: Point Auditorium DATE: 06/25/15 TO: Lance Francis FROM: Leslie Ellsworth

Roof Inspection. Summary Report

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

3 Installation. 9 Roof Edges... p Wall Terminations... p Membrane Repair... p Miscellaneous... p

Additions and Alterations

REPLACE ROOF AT CCAC NORTH CAMPUS. RADELET McCARTHY POLLETTA INCORPORATED ARCHITECTS AND INTERIOR DESIGNERS DRAWING SYMBOLS

Nominal Life Expectancy for Building Components

THERMAL AND MOISTURE PROTECTION WATERPROOFING

ROOF DRAINS TABLE OF CONTENTS

Renovating Your Basement

Transcription:

PUBLIC LIBRARY PHASE I 4828 W. 6TH Avenue, Unit B-8 Golden, Colorado 8040 Phone: (303) 233-092 VICINITY MAP SHEET INDEX GT /26/2009 SHEET DESCRIPTION G.0 COVER SHEET R.0 COMPOSITE ROOF PLAN R. NEW ROOF PLAN NEW ROOF DETAILS NEW ROOF DETAILS ABO DCL G-0.DWG COVER SHEET NO SCALE RG.0 5

ACCESS & SETUP NOTES:. FENCED SCAFFOLD ACCESS POINTS WILL BE NEEDED THROUGHTOUT THE PROJECT. 2. PERIODIC COORDINATED ACCESS WILL BE NEEDED AT THE PLAZA & SIDEWALK AREAS. 3. NO ENTRIES OR SIDEWALKS MAY BE BLOCKED WITHOUT COORDINATION WITH OWNER.. 4. LANDSCAPING AND SIDEWALK CONDITIONS PRIOR TO WORK SHALL BE DOCUMENTED. 4TH AVENUE ROOF DECK A PUBLIC LIBRARY ROOF DECK B ROOF DECK P2 ROOF DECK P ROOF DECK B ROOF DECK C ROOF DECK 4828 W. 6TH Avenue, Unit B-8 Golden, Colorado 8040 Phone: (303) 233-092 METAL ROOF - ROOF DECK P3 TILE ROOF PROJECT AREA IS SHADED GRAY ROOF DECK E ADD ALTERNATE #2 PATIO DECK - ROOF DECK Q BROADWAY STREET ROOF DECK D BASE BID ROOF DECK D BASE BID GT /26/2009 SCAFFOLD ACCESS AREA ROOF DECK F ROOF DECK G SCAFFOLD ACCESS AREA PATIO DECK - ROOF DECK O ADD ALTERNATE #3 ROOF DECK N ADD ALTERNATE # ROOF DECK I ROOF DECK R ROOF DECK H ROOF DECK R3 ROOF DECK J ABO DCL R-0.DWG R.0 COMPOSITE ROOF PLAN SCALE: /6" = '-0" (:92) ROOF DECK K ROOF DECK M ROOF DECK R2 ROOF DECK M ROOF DECK L 0 4' 8' 6' 32' COMPOSITE ROOF PLAN /6" = '-0" (:92) R.0 /6" = '-0" 2 5

264'-6" PUBLIC LIBRARY C DECK D DECK D 84' SIM. C DECK E C 4828 W. 6TH Avenue, Unit B-8 Golden, Colorado 8040 Phone: (303) 233-092 35'-3" B C DECK O DECK N B B 20'-6" GT /26/2009 R.0 NEW ROOF PLAN SCALE: 3/32" = '-0" (:28) SYMBOL LEGEND PARAPET WALL SAFTEY TIEBACK RAIL TAPERED INSUL. RIDGE TAPERED INSUL. VALLEY EXISTING ROOF SYSTEM - DECK D (BASE BID) " WOOD FIBER INSUL. BD. TAPERED EPS BEADBOARD (0.25/2) NEW ROOF SYSTEM - DECK D (BASE BID) EXISTING ROOF SYSTEM - DECK N (ADD ALT. #) " WOOD FIBER INSUL. BD. TAPERED EPS BEADBOARD (0.25/2) EXISTING ROOF SYSTEM - DECK E (ADD ALT. #2) " WOOD FIBER INSUL. BD. TAPERED EPS BEADBOARD (0.25/2) EXISTING ROOF SYSTEM - DECK O (ADD ALT. #3) " WOOD FIBER INSUL. BD. TAPERED EPS BEADBOARD (0.25/2) NEW ROOF SYSTEM - DECK N (ADD ALT. #) NEW ROOF SYSTEM - DECK E (ADD ALT. #2) NEW ROOF SYSTEM - DECK O (ADD ALT. #3) TAPER SLOPE (0.25/2) PRIMARY ROOF DRAIN OVERFLOW ROOF DRAIN TAPERED INSUL. DRAIN SUMP PIPE/CONDUIT WINDOW WASH DAVIT BASE EXHAUST FAN CURB ABO DCL R-.DWG NEW ROOF PLAN / TAPERED ISOCYANURATE FOAM INSUL. (0.25/2).5" ISOCYANURATE FOAM INSUL. BD. / TAPERED ISOCYANURATE FOAM INSUL. (0.25/2) / TAPERED ISOCYANURATE FOAM INSUL. (0.25/2) / TAPERED ISOCYANURATE FOAM INSUL. (0.25/2) DUCT CURB 0 6' 2' 24' 48' 3/32" = '-0" (:28) R. 3/32" = '-0" 3 5

LIFT & RESET STRAINER & CLAMP RING ASSEMBLY TO FLASH CARRY EPDM INTO CLAMP RING & SET IN WATERBLOCK TAPERED INSULATION SUMP 4'x4' DO NOT SHAVE INSULATION DETAIL NOTES. THICKNESS OF BASE LAYER OF INSULATION VARIES. 2. DENOTES EXISTING ITEM TO REMAIN, ALL OTHER ARE NEW. 3. DETAILS ARE EXPLODED FOR CLARITY. MAKE ALL CONNECTIONS WATERTIGHT..5" ISO. FOAM INSUL. BD. PUBLIC LIBRARY LAP SEALANT UNCURED EPDM PIPE WRAP STRIP-IN FLASHING ROOF DRAIN ASSEMBLY NOTE: FLASH OVERFLOW DRAIN THE SAME.LIFT & RESET OVERFLOW COLLAR. 60 MIL ADHERED TPO MEMBRANE C ROOF DRAIN FLASHING SCALE: 3" = '-0" (:4) STEEL PANEL CLEAT 5 LF OR SEALANT AT FAILED COPING SAW CUT 4" OFF BOTTOM OF.5" ISO. FOAM INSUL. BD. 4" 6" NOTE: AT TIE-BACK ANCHORS PROVIDE PITCH PAN IF PIPE CAN'T BE WRAPPED. PANEL COPING STONE 24 GA. GALVANIZED SHEET PIN TO WALL 8" O.C. TIE-BACK ANCHOR FLASHING SCALE: 3" = '-0" (:4) CONDUIT OR PIPE 4828 W. 6TH Avenue, Unit B-8 Golden, Colorado 8040 Phone: (303) 233-092 LAP SEALANT UNCURED EPDM PIPE WRAP STRIP-IN FLASHING.5" ISO. FOAM INSUL. BD. 60 MIL ADHERED TPO MEMBRANE WALL FLASHING SCALE: 3" = '-0" (:4) B SCALE: 3" = '-0" (:4) 5 LF OR SEALANT AT FAILED COPING.5" ISO. FOAM INSUL. BD. 00 LF OR SEALANT AT FAILED COPING PIPE/CONDUIT FLASHING SCALE: 3" = '-0" (:4) METAL DOOR GT /26/2009 COPING STONE PANEL COPING STONE THRESHOLD PLATE LIFT & RESET METAL EXPOSURE VARIES FROM DOOR TO DOOR CARRY EPDM FLASHING UNDER NEW GALV. FLASHING PIN TO CURB 2' O.C. 24 GA. GALV. FLASHING SET UNDER THRESHOLD PLATE - LIFT & RESET PANEL.5" ISO. FOAM INSUL. BD..5" ISO. FOAM INSUL. BD. ABO DCL R2-0.DWG NEW ROOF DETAILS 3" = '-0" (:4) SCALE: 3" = '-0" (:4) SCALE: 3" = '-0" (:4) DOOR THRESHOLD FLASHING SCALE: 3" = '-0" (:4) 4 5

DETAIL NOTES. THICKNESS OF BASE LAYER OF INSULATION VARIES. 2. DENOTES EXISTING ITEM TO REMAIN, ALL OTHER ARE NEW. 3. DETAILS ARE EXPLODED FOR CLARITY. MAKE ALL CONNECTIONS WATERTIGHT. PUBLIC LIBRARY SEALANT 24 GA. PRE-FINISHED SHEET PIN TO WALL 8" O.C. 22 GA. PRE-FINISHED SHEET METAL GRAVEL GUARD ~2'-6 NEW 3 4" PLYWOOD PLATE SECURED TO TOP OF EXISTING SHEET METAL MULTI-PIECE COPING CAP CARRY TPO MEMBRANE OVER TOP OF NEW PLYWOOD PLATE & DOWN WALL FACE 22 GA. GALV. SHEET METAL CLEAT, NAIL 8" O.C. CONCRETE KNEE WALL METAL ON WALL FRAMING 4828 W. 6TH Avenue, Unit B-8 Golden, Colorado 8040 Phone: (303) 233-092 34" CONCRETE KNEE WALL ~36" B SCALE: 3" = '-0" (:4) SCALE: 3" = '-0" (:4) LOUVER WALL METAL SILL FLASHING NEW 3 4" PLYWOOD PLATE SECURED TO TOP OF EXISTING SHEET METAL MULTI-PIECE COPING CAP SCHEDULE 00 LF OF COLORED SEALANT AT EXISTING METAL FLASHINGS AND LOUVER WALL STEEL PANEL CLEAT 22 GA. PRE-FINISHED SHEET METAL COPING CAP CARRY TPO MEMBRANE OVER TOP OF NEW PLYWOOD PLATE & DOWN WALL FACE GT /26/2009 4" 6" SAW CUT 4" OFF BOTTOM OF 24 GA. GALVANIZED SHEET PIN TO WALL 8" O.C. 22 GA. GALV. SHEET METAL CLEAT, NAIL 8" O.C. METAL ON WALL FRAMING CONCRETE CURB WOOD INFILL KNEE WALL REMOVE WALL TO FLASH CONCRETE KNEE WALL ~36".5" ISO. FOAM INSUL. BD. ABO DCL R2-.DWG NEW ROOF DETAILS 3" = '-0" (:4) SCALE: 3" = '-0" (:4) SCALE: 3" = '-0" (:4) WALL BASE FLASHING SCALE: 3" = '-0" (:4) 5 5