Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Similar documents
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Smart Cooling Solutions Data Center

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

CoolTeg Plus Chilled Water (CW) version: AC-TCW

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

CUSTOMER EXPERIENCE CENTER

How to Save Over 60% on Cooling Energy Needed by a Data Center? The Roadmap from Traditional to Optimized Cooling

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

EHDC. Cooling system for Data Center and server cabinets.

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Liebert HPM Designed for top level performance and reliability. Precision Cooling for Business-Critical Continuity

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized!

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Advantages and Efficient Use of Programmable Sockets. By Miguel Rascon AC Power Senior Product Manager

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

How To Make A Data Center More Efficient

Precision Cooling for Business-Critical Continuity. Liebert PCW. Cool the Cloud

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

White Paper Rack climate control in data centres

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

Microsoft Technology Center: Philadelphia

JAWAHARLAL NEHRU UNIVERSITY

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

How To Run A Data Center Efficiently

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

AIRAH Presentation April 30 th 2014

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

News in Data Center Cooling

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring

Elements of Energy Efficiency in Data Centre Cooling Architecture

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

How To Save Energy On A Power Supply

Liebert CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Liebert icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

Protecting Our Information, Protecting Our Resources

CRAC Precision climate control units for data centres

Virginia Tech. Background. Case Summary. Results

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

Improve competiveness of IDC and enterprise data centers with DCIM

In Row Cooling Options for High Density IT Applications

National Grid Your Partner in Energy Solutions

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Liebert NXC from 10 to 200 kva

Eaton 93PM UPS Where aesthetics meet intelligence.

Applying Proper Cable Management In IT Racks A Guide For Planning, Deployment And Growth

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

How To Improve Energy Efficiency In Data Center Management

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

DCIM Readiness on the Rise as Significant Data Center Capacity Remains Unused. A Research Report from the Experts in Business-Critical Continuity TM

DataCenter 2020: first results for energy-optimization at existing data centers

Dealing with Thermal Issues in Data Center Universal Aisle Containment

SiteWeb Monitoring System. Real Time Power and Environment Monitoring Platform for Telecom Applications

APC APPLICATION NOTE #112

IPSIP M series-m Modular Data Center

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

NetXtend Flex Series Integrated Outdoor Enclosure Solution. Outside Plant for Business-Critical Continuity

European Code of Conduct for Data Centre. Presentation of the Awards 2014

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity

Managing Cooling Capacity & Redundancy In Data Centers Today

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Comprehensive Solutions for Data Centers. Rely on Siemens for maximum uptime, reliability, and efficiency.

University of St Andrews. Energy Efficient Data Centre Cooling

Enterprise Remote Monitoring

- White Paper - Data Centre Cooling. Best Practice

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

Uninterruptible Power Supply Product Regulations and Standardization in the European Union. By Matteo Tricarico Patents and Regulatory Engineer

RiMatrix S Make easy.

Choosing Close-Coupled IT Cooling Solutions

Liebert PPC Second Generation Power Distribution Cabinet

Blade Server & Data Room Cooling Specialists

How to Build a Data Centre Cooling Budget. Ian Cathcart

STULZ View On DataCenter Cooling

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

ACTURA V DC, 3-40 kw, A. The Regional DC power system with Global Muscle

NetSure DC Power Solutions with esure High-Efficiency Technology. DC Power for Business-Critical Continuity TM

State of the Art Energy Efficient Data Centre Air Conditioning

Automation's Modular Containerized Datacenter Solutions

Transcription:

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Emerson Network Power Business-Critical Continuity so your success continues! Core competencies AC Power Connectivity DC Power Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant Power Switching & Controls Thermal Management Racks & Solutions Services Surge Protection No company, no matter how big or small, can afford business-critical system failures. Over the years we at Emerson Network Power have acquired unique know-how. Our name represents reliable rack systems, power supply, precision cooling, connectivity and integrated solutions. We can therefore ensure that you gain the maximum benefits from your technology investments. Thanks to Emerson Network Power's range of technology and extensive competencies, the entire bandwidth of company-wide solutions is supported for today's critical business requirements. Customers all over the world rely on our support for future-proof investments because they know that we offer specific innovations around the globe and optimized solutions from one single source supported by reliable local service and support. We can ensure the stable operation of your network infrastructure regardless of whether voice, data or multimedia content is to be transmitted. This is based on a time-proven, comprehensive portfolio of products, services and systems which supports a multitude of computing, telecommunications, health care and industrial applications. This creates a unique foundation of trust that is only possible by working together with Emerson Network Power. Our task is to prepare you for the unknown and the unexpected. We will guide you through the dynamic changes occurring in your business environment. We are also on hand to help you master the challenges this entails and take advantage of the greatest possible benefits of your technology investments. This is what we mean by Business-Critical Continuity. 2

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw Knürr DCL is the water-cooled high-performance cooling unit for lateral attachment to server cabinets. The next generation of the legendary Knürr CoolLoop - with optimized essential features Modularity Two room-neutral architectures for medium to high heat-load density Easy to retrofit on site Multiple combinations of up to four server racks Reliability N +1 fan redundancy Multi-level fail-safe controller Comprehensive alarm and monitoring functions Automatic emergency door opening Energy efficiency Minimized power consumption through EC fans and dynamic fan control Long free-cooling times thanks to a generously dimensioned heat exchanger Knürr DCL with Knürr DCM rack 4

Dynamic air supply through high-performance EC fans 5

Knürr DCL-L Closed Loop Cooling Architecture Modular combination possibilities Fully contained air flow inside the cabinet or the cabinet row No heat load, no air flow in the room, high noise attenuation Complete separation of IT equipment from room, accurately controlled cooling air temperature No special requirements for the room - raised floor is not required. Knürr DCL-L Knürr DCL-L with one Knürr DCM *30/34 kw per rack Knürr DCL-L Knürr DCL30L frontview High-density Server Rack cooled by two Knürr DCL-Ls *60/68 kw per rack 6

Knürr DCL Cooling capacity Height Height units in Knürr DCM DCL 30 30 kw 2,000 mm 42 U DCL 34 34 kw 2,200 mm 47 U Knürr DCL-L 2-1 combination *15/17 kw per rack Knürr DCL-L 4-1 combination *6/7 kw per rack * Top view cross-section: air flow pattern 7

Knürr DCL-L Hybrid Cooling Architecture Modular combination possibilities Hybrid configuration - air flow is contained in the cabinet or cabinet row and room. Knürr DCL-H Cooling units and cabinets are open at the front and closed at the back. No heat load in the room, warm air remains inside cabinets. Distribution of cold air throughout the room, cold air reserve in case of cooling system failure Better alternative to hot aisle containment No raised floor required 1-1 Knürr DCL H application * 30/34 kw per rack Knürr DCL-H Knürr DCL- H front view 2-1 Knürr DCL H application * 15/17 kw per rack 8

Knürr DCL Cooling capacity Height Height units in Knürr DCM DCL 30 30 kw 2,000 mm 42 U DCL 34 34 kw 2,200 mm 47 U Knürr DCL-H 1-3-1 combination *8/9 kw per rack for n+1 redundancy Knürr DCL-R Row cooling units for use in Smart Aisle cold aisle containments Alternative to Liebert CRV030/034 when the same controller as in Knürr DCL-L or Knürr DCL-H is required. Simple conversion to Knürr DCL-L or Knürr DCL-H through conversion of doors and replacement of sidepanels Knürr DCL-R in row with Knürr DCM * Top view cross-section: air flow pattern 9

Knürr DCL Availability An essential requirement for data-center operators is ensuring uninterrupted availability. Knürr DCL guarantees this by means of the following: "Fail-safe functioning ("safe despite faults") of the control valve: in the event of a power failure or interruption to the control line, the control valve switches the full volume of the chilled water flow to heat exchangers and the fans to full speed. Rack cooling controller hardware guarantees autonomous continued operation in the event of a component failure. Components continue to operate in a controlled way in "fail-safe" mode. Access control and data security guaranteed by HTTPS and SNMP V3. Alarm management can be integrated into DCIM (Data Center Infrastructure Management). Rack cooling controller implements the patented concept of regulating fan speeds based on indirect differential pressure measurement. Rack cooling controller ensures that all changes made to settings are traceable by means of login and event recording. Rack cooling controller architecture 10

Rack cooling controller Precise control of cooling air temperature and air flow through patented concept Even air distribution to all internal IT components Even temperature profile in the air supply n+1 fan redundancy means that the remaining fans support the volume flow required for cooling in the event of a fan failure. In the event of : - planned downtime or maintenance - or unnecessary cooling power, non-return flaps ensure that hot air can flow from the hot aisle into the data center s cold zone. Redundant A/B power supply with automatic operation Dual-circuit heat exchanger option ensures redundancy of the water supply if two independent chilled water circuits are installed. Optional integration into Knürr CoolVac systems guarantees leak proofing (patent pending). Automatic door opening provides additional overheating protection in case of cooling system failure. Rack cooling controller display output Automatic emergency door opening option for server rack Non-return flap open Non-return flap closed 11

Emerson Network Power Efficiency Simple fan change Knürr DCM server rack for cooling with Knürr DCL, Liebert power distribution modules and integrated cable management. Considering today's competitive market, no data-center operator can ignore the issue of costs. Anyone who only thinks about the upfront costs or who wants to cut costs at the expense of reliability will be left dealing with unpleasant surprises later on. Clever decision-makers will consider Knürr s experience of ensuring low running costs with maximum availability. Greater power density in the data center results in better utilization of space and reduced building costs. Reduced running costs due to customized operation High chilled water supply temperature increases the proportion of free cooling during refrigeration and improves the energy efficiency rating (EER) of the chiller. The control valve adjusts cold water volume flow for the current operational situation. Low water-side pressure drop leads to reduced pump power consumption. Energy cost savings by adjusting the fan speed to the air flow level actually required using the embedded controller Low air pressure drop leads to the fans using less power. EC fans guarantee energyefficient operation with maximum performance over the entire range of fan speeds. Operator support through the ability to display the "cooling power" efficiency value (ratio of electrical power consumption between servers and fans) Future-proof cooling solution: Knürr EC fans already comply with the energy efficiency requirements for CE approval applicable from 2015. Cooling power and energy efficiency (fan/pump power consumption for cold water connection) confirmed by independent institutions. 12

Adaptability Minimum possible investment for cooling components thanks to the option to use up to four server racks for each Knürr DCL Facilitates data-center upgrade through gradual expansion of the data center with no need to invest further in different cooling infrastructure. Can be adapted to different shapes and spaces - Heights 2,000 mm and 2,200 mm - Depths in 100 mm increments from 1,000 mm to 1,300 mm. Same base unit can be used for aisle cooling concepts and rack cooling with minimum conversion cost. Simple switchover between 2-way and 3-way valve by means of a ball valve in the bypass line Fans in Knürr DCL 2-way/3-way valve changeover Detail of Knürr DCL Data-center Setup 13

Knürr DCL Basic specification, Order table Knürr DCL basic specification Cooling performance/specifications Knürr DCL 30 KW Knürr DCL 34 KW Knürr DCL for rack cooling Knürr DCL30L Knürr DCL34L Knürr DCL for hybrid solution Knürr DCL30H Knürr DCL34H Knürr DCL for aisle cooling Knürr DCL30R Knürr DCL34R Nominal cooling power* 30 kw 34 kw Air flow 5,000 m 3 /h 6,000 m 3 /h Water flow 4.5 m 3 /h 5.0 m 3 /h Max. water pressure 10 bar (145 PSI) 10 bar (145 PSI) Number of fans 5 6 Fans max. power consumption 5 x 170 W 6 x 170 W Height 2,000 mm 2,200 mm Width 300 mm Dimensions DCL - L 1,200 mm - 1,300 mm Depth DCL - H DCL - R 1,100 mm - 1,300 mm 1,000 mm - 1,300 mm * Sensible cooling, at 16 C / 22 C (61 F / 72 F) water temperature, and 43 C (109 F) air inlet temperature 14 Knürr DCL with Knürr DCM

Knürr DCL unit configuration number Model number - Part 1/2 Model details Part 2/2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 D C L 3 0 L D C L 3 4 H D C L 3 0 R 1.-3. DCL (data center rack cooling solution) DCL Data Center Loop 4.-5. Nominal cooling capacity 30 30 kw (2,000 mm / 42U) 34 34 kw (2,200 mm / 47U) 6. Type of application L closed loop architecture (without external panels) H hybrid architecture (without external panels) R in row cooling (with external panels) 7. Depth 1 1,000 mm (DCL-R version only) R 1,100 mm (not for DCL-L version) 2 1,200 mm H 1,300 mm 8. Mechanical options 0 none (two units per pallet possible) D caster bracket (only one unit per pallet) 9. Electrical connection 2 230V AC 1-phase 50/60Hz CE 4 230V AC 1-phase 50/60Hz CE with A/B-transfer switch A 230V AC 1-phase 50/60Hz 2-pole CE B 230V AC 1-phase 50/60Hz 2-pole CE with A/B-transfer switch P 208 / 230V AC 2-pole 50/60Hz CSA S 208 / 230V AC 2-pole 50/60Hz CSA with A/B-transfer switch 10. Water connection / hex Z bottom Y top 9 top and bottom V redundant bottom 11. Filter N no filter A MERV 1 (NA for 1,000 mm depth) C MERV 1, clog switch (NA for 1,000 mm depth) 12. Display 0 none Y 5.7 display (14.5 cm) 13. Preparation for automatic door release system 0 - none 1 - prepared for one DCM server rack 2 - prepared for two DCM server racks 3 - prepared for three DCM server racks 4 - prepared for four DCM server racks 14. Chilled water monitoring 0 none T temperature sensor inlet/outlet 4 calorific meter 5 condensate pump 6 temperature sensor inlet/outlet + condensate pump 7 calorific meter + condensate pump 15. Environment monitoring 0 none S smoke detection H humidity monitoring B smoke detection and humidity monitoring 16. Color 1 RAL 7021 (gray - black) G RAL 7035 (light gray) 2 non standard color (SFA) 17. 18. Free 19. Communication 0 standard (HTTPS, SSH, MODBUS TCP, SNMP) D input/output customer M Modbus RTU B Bacnet V input/output customer + Modbus RTU W input/output customer + Bacnet 20. Server rack monitoring 0 none 1 - door contacts 1 rack 2 - door contacts 2 racks A - door contacts 3 racks B - door contacts 4 racks 3-2 temperature sensors 1 rack 4-2 x 2 temperature sensors 2 racks C - 3 x 2 temperature sensors 3 racks D - 4 x 2 temperature sensors 4 racks 7 - door contacts + temperature sensors 1 rack 8 - door contacts + temperature sensors 2 racks E - door contacts + temperature sensors 3 racks F - door contacts + temperature sensors 4 racks 21. Packaging P = land freight short distance (pallet, shrink wrap, cardboard protection) S = seaworthy (air freight) long distance (wooden crate) 22. Special features A = No SFAs, standard unit X = SFA included 23. 25. Factory configuration number 15

As at: November 2013 / Version 1.0 About Emerson Network Power Emerson Network Power, a business of Emerson (NYSE:EMR), delivers software, hardware and services that maximize availability, capacity and efficiency for data centers, healthcare providers and industrial facilities. A trusted industry leader in smart infrastructure technologies, Emerson Network Power provides innovative data-center infrastructure management solutions that bridge the gap between IT and facility management and deliver efficiency and uncompromised availability regardless of capacity demands. Our solutions are supported around the world by local Emerson Network Power service technicians. Learn more about Emerson Network Power products and services at: www.emersonnetworkpower.eu Emerson Network Power Global Headquarters 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229, USA T +1 614 8880246 Emerson Network Power EMEA Mariakirchener Straße 38 94424 Arnstorf, Germany T +49 8723 27 0 F +49 8723 27 154 info@knuerr.com Emerson Network Power United Kingdom George Curl Way Southampton SO18 2RY, UK T +44 (0)23 8061 0311 F +44(0)23 8061 0852 UK.Enquiries@Emerson.com While every precaution has been taken to ensure accuracy and completeness of this literature, Emerson Network Power and/or its affiliates makes no representations or warranty about the accuracy, reliability, completeness, or timeliness of the materials and disclaims any and all liability for damages resulting from use of this information or for any errors or omissions. 2013 Emerson Network Power. All rights reserved. Specifications subject to change without notice. MKA4LOUKDCL Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. 2013 Emerson Electric Co. 1101.150.108 DCL Subject to technical changes, errors and omissions.