HVDP. High Voltage Dynamic Power supply/source. 1, 2.5 and 5kW Output DC + Sine Wave Family



Similar documents
High Power Programmable DC Power Supplies PVS Series

PowerGem Pro Uninterruptible Power Supply

1.44 kw Programmable DC Power Supplies XLN Series

Multi-Range Programmable DC Power Supplies 9115 Series

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Multi-Range Programmable DC Power Supplies 9115 Series

Fundamentals of Signature Analysis

Annex: VISIR Remote Laboratory

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

High voltage tester HA 1800 Table-top device

DCS Series 1 kw, 1.2 kw, & 3 kw

Lesson 6: 6 EXAMPLES OF EMBEDDED SYSTEMS. Chapter-1L06: "Embedded Systems - ", Raj Kamal, Publs.: McGraw-Hill Education

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Lab 1: The Digital Oscilloscope

22 (21.5 viewable) Smart Display, Full HD, Rockchip Quad-Core, Optical touch, Android KitKat. VSD224

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Cod. Documento: RT a Title: Fimer Plant Controller Description. Rev. Data Redatto Approvato S.Sidoti A.

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

Driver Pant 8 and antenna switcher Ant 8. User manual

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

FREQUENCY RESPONSE ANALYZERS

TECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM

sat-nms SMU Signal Management Unit

FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment

38 Series - Relay interface modules A

How To Use An Hm804X Series Of Power Supplies

P545 Autonomous Cart

38 Series - Relay interface modules A

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

CLASS D POWER AMPLIFIERS

Smartphone garage door opener

15 Series - Electronic step relay and dimmer. Features SERIE

CONSTANT CURRENT REGULATOR INDUPERM TYPE CCR 951. Standarddescription of CONSTANT CURRENT REGULATOR TYPE CCR 951.

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

NETWORK ENABLED EQUIPMENT MONITOR

M1000 Process Alarm Monitor

Oscilloscope, Function Generator, and Voltage Division

Frequently Asked Questions: Home Networking, Wireless Adapters, and Powerline Adapters for the BRAVIA Internet Video Link

FRENIC5000MS5 for Machine Tool Spindle Drives

Charge Controller CC611/CC612 Preliminary datasheet

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Error-proofing for cordless assembly tools: Build it better with Bluetooth EXACT.

Considerations When Specifying a DC Power Supply

evolution wireless G3 evolution wireless Wireless Microphone Systems evolution wireless G3 Sets:

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Uninterruptible Power Supply

Quick Start Turning on the Tablet PC for the First Time

7-41 POWER FACTOR CORRECTION

Delta Transportation Automation Solution.

Signal Conditioning Amplifier System

Progettare per il Solid State Lighting: le sfide da superare

Chapter 4 Using Line Power Analysis

NGSS Data Consolidator (DC)

SNMP Web Management. User s Manual For SNMP Web Card/Box

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.

REMOTE HOST PROCESS CONTROL AND MONITORING OF INDUSTRY APPLIANCES

The answer to all current and future network demands

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

How To Sell A Talan

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

VAC 50/60Hz Power Adapter

CMP-102U. Quick Installation Guide

RLC Series Resonance

MasterINTERFACE 39 Series - Relay interface modules

Product Information Sheet UH36 Hi Pot Tester

BiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide

Pow-R-Con Multi Function Control

PLA 44. Power quality analyzer. User and service manual. BMR trading

Power Meter Series 700

= V peak 2 = 0.707V peak

LIFT CONTROL SYSTEMS CATALOGUE 2007

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

SCD Server. SCD Server Pro

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

INTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME. Ján Cigánek, Martin Janáček, Stanislav Števo

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

ABB central inverters PVS to 1000 kw

Using GIGABYTE Notebook for the First Time

2014 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo and other marks are trademarks of AT&T Intellectual Property.

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

BLE Series. Data setting software MEXE02 OPERATING MANUAL. Tabel of contents 1 Synchronization with the driver Monitor function...

TOSR-04-5 TOSR-10B/C. LazyBone. Smartphone Controlled Switch. User Manual

UNIVERSITY OF WATERLOO ELECTRICAL & COMPUTER ENGINEERING DEPARTMENT ME269 ELECTROMECHANICAL DEVICES AND POWER PROCESSING.

Quick Installation Guide DAP Wireless N 300 Access Point & Router

Understanding Power Factor, Crest Factor, and Surge Factor. White Paper #17

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Specification Requirements DBL 700MX and 1000MX Series UPS

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Research RF Sputtering Packages

Kramer Electronics, Ltd. Site-CTRL and Web Access Online User Guide (Documentation Revision 2)

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

been built in for recall of the stored settings at any time. For automated testing, the save and recall functions can save a great deal of time.

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

integration tools setup guide SIM 3 Remote Guide to controlling a SIM 3 Audio Analyzer remotely over a network connection from a laptop

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

Transcription:

Milano, 12 March 2015 HVDP High Voltage Dynamic Power supply/source 1, 2.5 and 5kW Output DC + Sine Wave Family HVDP (High Voltage Dynamic Power) is a family of power supply/source designed to generate a wide range of output power waves. The HVDP here presented is the DC and output sine wave equipment.

HVDP 19 rack 6U box front panel The HVDP touch screen display is a smart interface for the operator. The figure shows the current screen displayed; other screens are available, by pushing the menu key, to enable other equipment features.

A set values are indicated on the screen, in the right position, and precisely: current (A); voltage (V); frequency (Hz). If the output is sine wave (frequency 0) the current and the voltage is the RMS value. These values can be set by the up-down arrows or by a keyboard showed on the screen when voltage, current or frequency digits are touched. On left position on the screen are indicated the actual output voltage (V) and actual output current (A) values. When the output is sine wave (frequency 0) the voltage and current showed are the RMS value. HVDP touch screen display

HVDP general FEATURES: output power up to 5kW output voltage up to ±1kV pk (700V rms ); output current up to 10A rms ; output regulation: voltage mode or/and current mode; power output shape: o sine wave from 20Hz to 500Hz up to 700V rms ; o DC from -800V dc to +800V dc output sine wave with positive and negative offset superimposed on voltage and/or in current; output sine wave with harmonics superimposed (i.e. 3 rd harmonic); input-output 10kV insulation. output line floating to earth; short circuit protection; friendly human interface with touch screen; remote control connection: Ethernet channel (ISO/IEEE 802/3) and by wireless WiFi connection; customer test stretch, based on several voltages, currents or frequencies, are easily programmable; easy programmable voltage and current positive and negative slope; easy programmable frequency slope; fast and accurate output voltage and current detection and monitoring; over 90% efficiency from 50% to 100% load; over 85% efficiency from 10% to 50% load. input line: single phase 230V ac or 400V ac ; 50 60Hz; The output of HVDP supply/source can be controlled in voltage, current and frequency. The output is insulated from the input line up to 10kV and is floating to earth. This is an important feature for operator safety. HVDP is equipped with a Ethernet channel (ISO/IEEE 802/3) to connect in local your PC or to allow a remote control by LAN. Moreover it is possible to connect the equipment by wireless WiFi.

HVDP APPLICATION: electronic circuit test; a.c. motor driver; electric motor test; power filter test; transformer test; electrical appliance test; current mode high power LED system driver; switch, relay and other electro-mechanical equipment test;

HVDP equipment can be controlled: by the touch screen display located on front panel. A friendly HVDP-HMI (HVDP Human Interface) software application, installed on the HVDP main processor, allows you to setup all the operational data (voltage, current, frequency, timing etc.) and to monitor run time all the parameters. The human interface is realized with an easy-to-use touch screen on a 7 inch, 260k colors display, integrated on HVDP front panel. by a PC connected by Ethernet (ISO/IEEE 802/3): by using your preferred browser: The HVDP has a built-in webserver: additional to the integrated display, it is possible to control the HVDP equipment by your PC connected by Ethernet (ISO/IEEE 802/3) or via WiFi wireless connection. All the features available on the HVDP display are proposed on the PC by using your preferred browser. It is possible

to load the operational data setup and to monitor run-time parameters from your PC, like from the integrated touch screen display. Of course you can use, instead your PC, other devices like tabled or mobile phone. by using HVDP protocol: Moreover it is possible to send to HVDP, by the Ethernet channel, command and monitoring functions. The HVDP command/monitoring function protocol is well documented in the technical datasheets. Some examples are available to easily develop your application. However L&F, on your request, can realize a customize application. HVDP-HMI follows you all the time during your work: from the GO to the STOP command. Moreover HVDP-HMI is able to give you, in real time, a lot of information about the output parameters: voltage, current, frequency, load cosφ, loads resistance, real power etc. HVDP is able to show, on the integrated display or on your PC screen, the voltage and current wave shape as on an oscilloscope.

Table 1: HVDP output DC + sine wave family HVDP DC + sine wave family line 230V ac order code line 400V ac order code HVDP 1kW HVDP.1ph.1kW.230Vac HVDP.1ph.1kW.400Vac HVDP 2,5kW HVDP.1ph.2,5kW.230Vac HVDP.1ph.2,5kW.400Vac HVDP 5kW ------- HVDP.1ph.5kW.400Vac The table 1 shows the HVDP output DC+sine wave family standard equipment available. The table 2 shows the boundary of the DC output operative area for 1kW, 2,5kW and 5kW HVDP. Inside this operative area it is possible to define output current setup and/or output voltage setup needed for a specific application.

AC output voltage (V rms ) The table 3 shows the same of table 2 for sine wave output. In this table The values are RMS. 1000 Table 3: HVDP 1kW, 2,5kW, 5kW sine wave output operative area 900 800 700 600 500 400 HVDP 1kW HVDP 2,5kW HVDP 5kW 300 200 100 0 0 1 2 3 4 5 6 7 8 9 10 output current (A rms ) L&F reserves the right to change the technical details present in this document any moment and without any notice.