Headend Cables. High-Performance Products For Every Headend Application



Similar documents
Precision Video Cable for Analog and Digital Overview

Analog Multi-Pair Snake Cable High-Flex and NEC Rated Cables

RGB Component Video Cable Bundled RGB Coaxial Cables Miniature and High-Flex Type

HomeChoice Cables. Data & Voice Cable Video Cable Audio Cable Security Cable Composite Cable

Microphone and Musical Instrument Cable Overview

les ab C eration en G ew N

shipboard safety and communications.

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

Coaxial Cable 5. Electronics

Coaxial Cables. Table of Contents. Coaxial Cables 6.1

Industrial Data Solutions

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

Communication, Signal & Data Cables

Coaxial Cable Solutions Guide

Broadcast and Commercial AV Cabling MASTER CATALOG

Broadband Coax Cables

Table of Contents. Brilliance Broadcast Cables

Security & Control Cables

West Penn Wire. Access Control Systems and Cables WEST PENN WIRE CABLE WITH CONFIDENCE

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

WIRE & CABLE PRODUCTS

Table of Contents. Industrial Coax. Blue Hose Cables Twinaxial Cables DataTray 600V Twinaxial Cables 18.17

ULTIMATE SNAP-N-SEAL

Serial Data Grade Cables

Products. Technology. Services. Delivered Globally. LOW-VOLTAGE CABLING SOLUTIONS

Sound, Alarm & Security Cable 7

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Standards Affecting a Premise T-1 Installation

Communication and Control Cable Fire Alarm Cable Coaxial Cable ( CAT V / M ATV & CCTV Cables)

Why FOUNDATION Fieldbus?

Specification SFTP CAT6 Network Cable 23AWG CU

ETHERLINE Ethernet Cable, Connectors & Tools

Industrial Ethernet Cable Solutions

RF & Microwave cable assemblies C291

Data Cables. European Edition

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

" EXCEEDING EXPECTATIONS WITH PERFORMANCE "

2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com

Network Engineers Everywhere:

LS Data Communication Product

Uniprise Solutions COAX 101. White Paper.

MICROCABLES. A complete vision of your connectivity needs. Catalogue

Gulf Cable & Electrical Ind. Co.

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

Cable Substitution Chart

Belden Marketing Quarterly Newsletter

COAX Cables Radio Frequency Cables

Solving Signal Problems Effective shielding is key to enhancing the reliability and performance of broadcast cables.

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

MarineTuff Offshore and Marine Cable Solutions

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION

ATT-TP Ethernet Copper Cable & Ethernet Copper Assembly Specification

Ethernet Cat 5e & Cat 6 Patch Panels

Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof

Western Cable Corporation

Outside Telephone Cable

Coaxial Cables and Applications Contributed By: Martin J. Van Der Burgt Senior Product Engineering Project Manager, Belden Electronics Division

Combined with Accessories

Copper Cabling Infrastructure Offering

Total Solutions Verification

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

fiberopt Whirlwind Fiber Optic Solutions product guide Ling Rd. Rochester, NY whirlwindusa. com

Audio/Video Solutions For System Integrators

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

Coaxial Cables for Medium-Frequency Applications

How to Choose the Right Cable Category

SOUND/SECURITY FIRE ALARM/LIFE SAFETY TEMPERATURE CONTROLS COAXIAL DATACOM HARDWARE FIBER OPTIC SPECIAL APPLICATION C ATALOG, VOL.

Instrumentation Cable Power Cable Assembly Solutions...32

CCTV System Troubleshooting Guide

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

75 Ω Transmission System

Errata NFPA 70. Proposed 2014 Edition

Cables and Accessories Selection Guide

PANDUIT TX6 10GIG SHIELDED COPPER CABLING SYSTEM. Innovative Connectivity Solution for Maximum Performance and Security

Super-Flex Traveling Cable Type ETT/300V

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

RF cables. Edition 2015

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Chapter 4 Connecting to the Internet through an ISP

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

Industrial Data Solutions. Belden

MacArtney Underwater Cables - In stock

LIFE-LINE Safety Cables Continuous Bending Hi-Flex Electrical Cables to Guarantee Safe Cable & Hose Carrier Systems

Disclaimer This information is collected and composed by QUANG DUNG TECHNOLOGY from Cablingdb.com. All information is copyrighted by Cablingdb.com.

Standard Buccaneer - Ethernet

Reliable, Consistent, Quality

Terminating 25-Pair Cable and 4-Pair Cross Connects

Crestron CAT5 Wiring Reference Guide

SPECIALTY CABLES APPLICATIONS SUPPORTED

100% EMI Emission Containment

E Series. E Series. Category 6 and 5e. Features

Transcription:

Headend Cables High-Perforance Products For Every Headend Application

The Evolution Headend Technology and Belden s Full Range Cable Solutions Headend cables will need to be increasingly high-end in nature. The factors that will shape the future the headend, the heart precision CATV activity, are already at work, changing the industry. Many challenging technology drivers are now converging, including the copetitive necessity to accoodate services like these: High-definition TV (HDTV) Interactive TV services Video on deand (VOD) Internet telephony (VoIP) High-speed data transission Targeted advertising (zoning) Personal counications services (PCS) The proliferation educational and governent channels Headend consolidation By 2007, all broadcast television will be digital by law, and satellite networks have already ade the switch. Analog audio will reain viable in the headend in order to serve both digital and analog technologies but certainly by 2008 the overwheling ajority services will be digitally-based. To handle this technology evolution, headend cables will need to be increasingly ore high-end in nature. Belden stands alone in its ability to fer a variety high quality, high reliability cables for every facet the headend. Today s consuer is looking for a range new CATV services - all ipacting the headend. ENJOY OUR F E A T U R E P R E S E N T A T I O N

Cables for Every Headend Need Built for the Future By ost accounts, the future is now. We see super-headends in larger urban areas, highly digital and linked to antenna fars. To copleent those, we have saller hubs serving saller populations and towns. Consider the fusion zones handling different types data, encoding-forats and protocols. Cabling will be a ix coax, fiber, and twisted pairs. Reliability is crucial. Outages and downtie are not tolerated. To that effect, cable engineers are being challenged to design and build headends that will work a decade fro now an era where digital is the nor. Today, our headend custoers are increasingly being asked to squeeze ore and ore products and services out the sae real estate. The headend s existing square footage will be used ore efficiently, learning to fer ore channels per rack. As a result, we see a deand for cabling and associated connectors with a saller for factor. You can safely trust Belden high-perforance cable products. Manufactured to the highest standards quality with the ost advanced equipent, controls and processes, Belden products will give you the edge you re going to need, now and in the future. The cables shown here are indicative the quality and reliability that you have coe to expect fro Belden. Our Satellite to receiver cables feature Belden s superior shielding technology all swept to 3 GHz To interconnect a variety signal processing equipent we fer a nuber high-end RF products including bundled and ulti-coax designs in both ini and standard coax diaeters Our SDI cables are considered the top-perforing cables in the Broadcast industry; all eet SMPTE 292M and ITU-R-BT.60 for PAL standards Ideal for VoIP equipent interconnects, our Data cables are networking industry leaders Our Single- and Double-Pair Digital Audio cables exceed AES/EBU specifications An extensive range DS-3 and DS-4 cables for central fice and voice Optical Fiber cables for patch and distribution. High fiber counts are available As this is erely an overview available products, please be aware that your local sales representative can answer any application question that you ight have. Belden is fully coitted to your future, just ask. TABLE OF CONTENTS Page Satellite Cable 4 RF Cable 6 SDI Cable 0 VoIP Cable 3 Digital Audio Cable 6 DS-3 and DS-4 Cable 7 Optional Fiber Cable 8 Technical Inforation 9 Top-perforing satellite cables are just part our fering. 3

Satellite Cable All Belden Satellite coaxes are swept to 3 GHz, plus they are available in a variety shield types, including Duobond II (Foil/Braid), Duobond IV (Quad Shield) and the superior Duobond Plus (Foil/Braid/Foil). Attributes include solid copper conductors or copper covered steel conductors and PVC or Flaarrest jackets. Although not listed here, we also fer Single- and Dual-pair constructions with 22 AWG stranded tinned copper conductors, overall Beldfoil shields and drain wires. RG-6/U Coax Lengths Conductor (stranding) Diaeter No. DCR Core OD Shielding OD Inch No. DCR Inch No. Ip. No. Vel. Prop. Capacitance pf/ pf/ MHz Attenuation 00 00 8 AWG Solid.040" Bare Copper or Bare Copper-covered Steel Conductor Duobond II + Aluinu Braid Shield (60% Coverage) Gas-injected Foa Polyethylene Insulation PVC Jacket (Black, Gray, White or Neutral) 80 C 829A NEC: U-000 U-304.8 27.0 2.3 8 AWG.80 4.57 Duobond II*.270 6.86 75 83% 6.2 53.2 CATV CM 000 304.8 27.0 2.3 (solid) + 60% CEC:.040" Aluinu CM BCCS Braid 00% Sweep tested. 950 MHz to 3 GHz. 28.0Ω/M 9.0Ω/M 9.9Ω/k 29.5Ω/k 80 C 829AC NEC: U-000 U-304.8 27.0 2.3 8 AWG.80 4.57 Duobond II*.270 6.86 75 83% 6.2 53.2 CATV CM 000 304.8 27.0 2.3 (solid) + 60% CEC:.040" Aluinu CM BCAC Braid 00% Sweep tested. 950 MHz to 3 GHz. 6.4Ω/M 9.0Ω/M 2.0Ω/k 29.5Ω/k U-000 ft. put-up available in Black, White or Gray only. 000 ft. available in White or Black only. 80 C 829R NEC: U-000 U-304.8 3.0 4. 8 AWG.80 4.57 Duobond II*.270 6.86 75 83% 6.2 53.2 u CATVR, (solid) + 60% CMR.040" Aluinu CEC: BCCS Braid CMG FT4 28.0Ω/M 9.0Ω/M 9.9Ω/k 29.5Ω/k U-000 ft. put-up not available in Neutral. Plenu Foa FEP Insulation Natural Flaarrest Jacket 75 C 829P NEC: U-000 U-304.8 27.0 2.3 8 AWG.70 4.32 Duobond II*.235 5.97 75 83% 6.3 53.5 u CATVP, CMP 000 304.8 27.0 2.3 (solid) + 60% CEC:.040" Aluinu CMP FT6 BCCS Braid 00% Sweep tested. 5 MHz to 3 GHz. 28.0Ω/M 9.0Ω/M 9.9Ω/k 29.5Ω/k BCAC = Bare Copper Anti-corrosion BCCS = Bare Copper-covered Steel DCR = DC Resistance FEP = Fluorinated Ethylene Propylene * Duobond II = Bonded Duoil (00% coverage + aluinu braid (67% coverage). 00% Sweep tested. 950 MHz to 3 GHz. 5.5.6 55.4 4.6 2 2.6 8.5 500 4. 3.5 750 5. 6.7 862 5.5 8.0 000 6.0 9.7 450 7.8 25.6 800 8.6 28.2 2250 9.8 32.2 3000.3 37. 5.5.6 55.4 4.6 2 2.6 8.5 500 4. 3.5 750 5. 6.7 862 5.5 8.0 000 6.0 9.7 450 7.8 25.6 800 8.6 28.2 2250 9.8 32.2 3000.3 37. 5.5.6 55.4 4.6 2 2.6 8.5 500 4. 3.5 750 5. 6.7 862 5.5 8.0 000 6.0 9.7 450 7.8 25.6 800 8.6 28.2 2250 9.8 32.2 3000.3 37..3.0 0.7 2.3 50.5 4.9 00 2. 6.9 200 3.0 9.8 400 4.4 4.4 700 6. 20.0 900 7.2 23.6 000 7.6 24.9 450 9.6 3.5 800.0 36. 2250 2.7 4.7 3000 5. 49.5 4

Satellite Cable (continued) RG-6/U Coax Lengths Conductor (stranding) Diaeter No. DCR Core OD Shielding OD Inch No. DCR Inch No. Ip. No. Vel. Prop. Capacitance pf/ pf/ MHz Attenuation 00 00 8 AWG Solid.040" Bare Copper Conductor Duobond Plus + Aluinu Braid Shield (77% Coverage) + Aluinu Foil Gas-injected Foa Polyethylene Insulation PVC Jacket (Black or White) 80 C 795A NEC: U-500 U-52.4 6.5 7.5 8 AWG.80 4.57 Duobond Plus *.275 6.99 75 83% 6.2 53.2 CATV CM 500 52.4 8.0 8.2 (solid) 77% CEC: U-000 U-304.8 30.0 3.6.040" Aluinu CM 000 304.8 30.0 3.6 BC Braid 00% Sweep tested. 5 MHz to 3 GHz 6.4Ω/M 4.6Ω/M 2.0Ω/k 5.Ω/k Shorting Fold 8 AWG Solid.040" Bare Copper Conductor Duobond + Aluinu Braid Shields (60% and 40% Coverage) Gas-injected Foa Polyethylene Insulation PVC Jacket (Black or White) 80 C 796A NEC: U-500 U-52.4 8.5 8.4 8 AWG.70 4.32 Duobond IV*.248 6.30 75 83% 6.2 53.2 CATV CM 500 52.4 6.5 7.5 (solid) 60% & CEC: U-000 U-304.8 33.0 5.0.040" 40% CM 000 304.8 35.0 5.9 BC Aluinu 00% Sweep tested. 5 MHz to 3 GHz. 6.4Ω/M 2.0Ω/k Braids 4.8Ω/M 5.7Ω/k 80 C 796AP NEC: U-000 U-304.8 33.0 5.0 8 AWG.70 4.32 Duobond IV*.248 6.30 75 83% 6.2 53.2 CATVP, CMP 000 304.8 35.0 5.9 (solid) 60% & CEC:.040" 40% CMP FT6 BC Aluinu 00% Sweep tested. 5 MHz to 3 GHz. 6.4Ω/M 2.0Ω/k Braids 4.8Ω/M 5.7Ω/k 5.5.6 55.4 4.6 2 2.6 8.5 500 4. 3.5 750 5. 6.7 862 5.5 8.0 000 6.0 9.7 450 7.8 25.6 800 8.6 28.2 2250 9.8 32.2 3000.3 37. 5.5.6 55.4 4.6 2 2.6 8.5 500 4. 3.5 750 5. 6.7 862 5.5 8.0 000 6.0 9.7 450 7.8 25.6 800 8.6 28.2 2250 9.8 32.2 3000.3 37..3.0 0.7 2.3 50.5 4.9 00 2. 6.9 200 3.0 9.8 400 4.4 4.4 700 6. 20.0 900 7.2 23.6 000 7.6 24.9 450 9.6 3.5 800.0 36. 2250 2.7 4.7 3000 5. 49.5 RG-/U Coax 4 AWG Solid.064" Bare Copper-covered Steel Conductor Duobond IV + Aluinu Braid Shield (60% and 40% Coverage) Foa FEP Insulation Solef PVDF Jacket 80 C 7999AP NEC: 000 304.8 69.0 3.4 4 AWG.274 6.96 Duobond IV*.372 9.45 75 83% 6.3 53.5 CATVP, CMP (solid) 60% & CEC:.064" 40% CMP FT6 BC Aluinu 00% Sweep tested. 5 MHz to 3 GHz..0Ω/M 36.Ω/k Braids 3.0Ω/M 9.84Ω/k BC = Bare Copper DCR = DC Resistance FEP = Fluorinated Ethylene-propylene PVDF = Polyvinylidene Fluoride * Duobond Plus = Bonded Duoil (00% coverage) + aluinu braid (67% coverage) + shorting fold Duobond IV = Bonded Duoil (00% coverage) + aluinu braid (67% coverage) + Duoil (00% coverage) + aluinu braid (46% coverage).2.7 0.5.6 50.9 3.0 00.3 4.3 200.9 6.2 400 2.8 9.2 700 3.9 2.8 900 4.7 5.4 000 5.0 6.4 450 6.7 22.0 800 7.7 25.3 2250 8.5 27.9 3000 9.9 32.5 5

Satellite Cable (continued) RG-/U Coax Lengths Conductor (stranding) Diaeter No. DCR Core OD Shielding OD Inch No. DCR Inch No. Ip. No. Vel. Prop. Capacitance pf/ pf/ MHz Attenuation 00 00 4 AWG Solid.064" Bare Copper-covered Steel Conductor Duobond II + Aluinu Braid Shield (60% Coverage) Foa FEP Insulation Solef PVDF Jacket 80 C 7999A NEC: 000 304.8 67.0 30.4 4 AWG.280 7. Duobond II*.400 0.6 75 83% 6.2 53.2 CATV (solid) + 60% 000 ft. put-up also available in White. CM.064" Aluinu CEC: BCCS Braid CM.0Ω/M 4.Ω/M 36.Ω/k 3.4Ω/k 00% Sweep tested. 5 MHz to GHz..2.7 0.5.6 50.9 3.0 00.3 4.3 200.9 6.2 400 2.8 9.2 700 3.9 2.8 900 4.7 5.4 000 5.0 6.4 450 6.7 22.0 800 7.7 25.3 2250 8.5 27.9 3000 9.9 32.5 RF Cable Belden is the industry leader in high-end RF products that are used in the interconnect a variety signal processing equipent in the Headend. These cables feature the following shields: Duobond II (Fold/Braid), Duobond IV (Quad Shield) and the superior Duobond Plus (Foil/Braid/Foil). There are also any variations bundled and ulti-coax Banana Peel designs (available by special request) to suit any application. Most RF products are available in 2 colors. RG-59/U Coax Lengths Conductor (stranding) Diaeter No. DCR Core OD Shielding OD Inch No. DCR Inch No. Ip. No. Vel. Prop. Capacitance pf/ pf/ MHz Attenuation 00 00 20 AWG Solid.032" Silver-plated, Copper-covered Steel Conductor Duobond Plus + Aluinu Braid Shield (95% Coverage) Gas-injected Foa Polyethylene Insulation PVC Jacket (Available in 3 colors)* 80 C 967 NEC: 000 304.8 24.0 0.9 20 AWG.44 3.66 Duobond Plus*.242 6.5 75 83% 6.2 53.2 CATVR (solid) + 95% CMR.032" Aluinu CEC: SPCCS Braid 00% Sweep tested. 5 MHz to GHz CMG FT4 25.8Ω/M 4.5Ω/M 84.6Ω/k 4.8Ω/k Shorting Fold *Available in Black, Gray, White, Red, Blue, Yellow, Brown, Orange, Green, Purple, Beige, Pink or Aqua. BCCS = Bare Copper-covered Steel DCR = DC Resistance FEP = Fluorinated Ethylene Propylene PVDF = Polyvinylidene Fluoride SPCCS = Silver-plated, Copper-covered steel * Duobond II = Bonded Duoil (00% coverage + aluinu braid (67% coverage). Duobond IV = Bonded Duoil (00% coverage) + aluinu braid (67% coverage) + Duoil (00% coverage) + aluinu braid (46% coverage).75 2.46 55.84 6.04 2 3.36.02 26 3.4.9 240 3.57.7 270 3.79 2.43 300 3.99 3.09 325 4.6 3.65 350 4.33 4.2 375 4.49 4.73 400 4.66 5.29 450 4.96 6.27 500 5.22 7.3 550 5.48 7.98 600 5.75 8.86 650 6.03 9.78 700 6.28 20.60 750 6.5 2.36 800 6.7 22.0 862 6.97 22.87 870 7.00 22.97 900 7.4 23.42 000 7.68 25.20 6

RF Cable (continued) RG-59/U Coax Lengths Conductor (stranding) Diaeter No. DCR Core OD Shielding OD Inch No. DCR Inch No. Ip. No. Vel. Prop. Capacitance pf/ pf/ MHz Attenuation 00 00 20 AWG Solid.032" Silver-plated, Copper-covered Steel Conductor Bonded Duoil + 2 Aluinu Braid Shields (95% Coverage) + Duobond Plus Gas-injected Foa Polyethylene Insulation PVC Jacket (Available in 3 colors)* 80 C V0077 000 304.8 39.0 7.7 20 AWG.44 3.66 Bonded.270 6.86 75 83% 6.2 53.2 5.75 2.46.032" Duoil 55.84 6.04 SPCCS + 95% 2 3.36.02 25.8Ω/M + 95% 26 3.4.9 00% Sweep tested. 5 MHz to GHz. 240 3.57.7 84.6Ω/k Aluinu Braid 270 3.79 2.43 + Duobond Plus 300 3.99 3.09 6.6Ω/M 325 4.6 3.65 2.Ω/k 350 375 4.33 4.49 4.2 4.73 400 4.66 5.29 450 4.96 6.27 500 5.22 7.3 550 5.48 7.98 600 5.75 8.86 650 6.03 9.78 700 6.28 20.60 750 6.5 2.36 800 6.7 22.0 862 6.97 22.87 870 7.00 22.97 900 7.4 23.42 000 7.68 25.20 *Available in Black, White, Pink, Tan, Green, Gray, Brown, Red, Orange, Yellow, Aqua, Blue or Violet Mini RG-59/U Coax 3.0 GHz Sweep Test, Guaranteed Return Loss Specs Gas-injected Foa HDPE Insulation Overall PVC Jacket (See available colors) YR46940 NEC: 250 76.2 4.5 2.0 23 AWG.02 2.59 Duobond II.59 4.03 75 83% 6.3 53.5 CMR U-500 U-52.4 9.0 4. (solid) + 95% CEC: 000 304.8 7.0 7.7.023" TC Braid CMG FT4 BC 7.6Ω/M Outer and inner jackets: 20.Ω/M 24.9Ω/k Black Gray 65.9Ω/k Brown White Red Green Orange Blue Yellow Violet Aqua Pink Meets ANSI/SCTE 7 2006 250 ft. and U-500 ft. put-ups available in Black only. 5.9 3.0 42 2.3 7.5 55 2.6 8.5 65 2.8 9.2 70 3.0 9.8 2 4.7 5.4 26 4.8 5.8 240 5. 6.7 270 5.4 7.7 300 5.7 8.6 325 5.9 9.4 350 6. 20.0 375 6.3 20.8 400 6.6 2.5 450 7.0 22.9 500 7.4 24.2 550 7.8 25.6 600 8.3 27.3 650 8.8 28.9 700 9.3 30.4 750 9.6 3.5 800 9.8 32. 862 0.0 32.8 870 0. 33. 900 0.2 33.5 950 0.3 33.8 000 0.5 34.4 500 3.0 42.6 2250 6.0 52.5 3000 8.5 60.7 BC = Bare Copper DCR = DC Resistance HDPE = High-density Polyethylene SPCCS = Silver-plated, Copper-covered steel TC = Tinned Copper 7

RF Cable (continued) RG-59/U Coax Coax Conductor Shielding (stranding) Core OD OD No. No. Lengths Ip. Vel. Capacitance Diaeter No. DCR Inch No. DCR Inch Prop. pf/ pf/ MHz Attenuation 00 00 Bundled RG-59/U Coax 3.0 GHz Sweep Test, Guaranteed Return Loss Specs, Coax Identification: Nubered Gas-injected Foa HDPE Insulation Overall PVC Jacket (See available colors) YR48335 NEC: 4 500 52.4 55.5 25.2 23 AWG.02 2.59 Duobond II*.48 2.22 75 83% 6.3 53.5 CMR 000 304.8 09.0 49.5 (solid) Coax OD: + 95% Inner jackets nubered. CEC:.023".59 4.03 TC Braid Available in four outer and inner CMG FT4 BC 7.6Ω/M jacket colors: 20.Ω/M 24.9Ω/k Matte Blue Matte Red 65.9Ω/k Matte Yellow Red Meets ANSI/SCTE 7 2006 YR4793 NEC: 8 500 52.4 07.0 48.6 sae sae sae.638 6.2 75 83% 6.3 53.5 CMR 000 304.8 24.0 97.2 as as as Inner jackets nubered. CEC: above above above Available in twelve outer and inner CMG FT4 jacket colors: Aqua Matte White Matte Black Matte Orange Matte Yellow Matte Brown Green Red Blue Violet Gray Pink Meets ANSI/SCTE 7 2006 YR4772 NEC: 0 000 304.8 39.0 45.0 sae sae sae.796 20.22 75 83% 6.3 53.5 CMR as as as Inner jackets nubered. CEC: above above above Available in six outer and inner CMG FT4 jacket colors: Matte Black Matte White Matte Yellow Green Red Blue Meets ANSI/SCTE 7 2006 YR48336 NEC: 2 500 52.4 7.5 78.0 sae sae sae.825 20.96 75 83% 6.3 53.5 CMR 000 304.8 353.0 60.3 as as as Inner jackets nubered. CEC: above above above Available in five outer and inner CMG FT4 jacket colors: Matte Black Matte Red Matte Yellow Matte Blue Red YR48327 NEC: 6 000 304.8 464.0 20.7 sae sae sae.96 23.27 75 83% 6.3 53.5 CMR as as as Inner jackets nubered. CEC: above above above Available in six outer and inner CMG FT4 jacket colors: Matte Black Matte Yellow Matte Brown Matte Blue Matte Red Red BC = Bare Copper DCR = DC Resistance HDPE = High-density Polyethylene TC = Tinned Copper *Duobond II = Bonded Duoil (00% coverage + aluinu braid (67% coverage). 5.9 3.0 42 2.3 7.5 55 2.6 8.5 65 2.8 9.2 70 3.0 9.8 2 4.7 5.4 26 4.8 5.8 240 5. 6.7 270 5.4 7.7 300 5.7 8.6 325 5.9 9.4 350 6. 20.0 375 6.3 20.8 400 6.6 2.5 450 7.0 22.9 500 7.4 24.2 550 7.8 25.6 600 8.3 27.3 650 8.8 28.9 700 9.3 30.4 750 9.6 3.5 800 9.8 32. 862 0.0 32.8 870 0. 33. 900 0.2 33.5 950 0.3 33.8 000 0.5 34.4 500 3.0 42.6 2250 6.0 52.5 3000 8.5 60.7 8

RF Cable (continued) RG-59/U Coax Coax Conductor Shielding (stranding) Core OD OD No. No. Lengths Ip. Vel. Capacitance Diaeter No. DCR Inch No. DCR Inch Prop. pf/ pf/ MHz Attenuation 00 00 Bundled RG-59/U Coax 3.0 GHz Sweep Test, Guaranteed Return Loss Specs, Coax Identification: Nubered Gas-injected Foa HDPE Insulation Overall PVC Jacket (See available colors) YR4694 NEC: 3 500 52.4 46.5 2. 23 AWG.02 2.59 Duobond II.440.8 75 83% 6.3 53.5 CMR 000 304.8 93.0 42.3 (solid) Coax OD: + 95% CEC:.023".59 4.03 TC Braid Inner jackets color coded (see chart). CMG FT4 BC 7.6Ω/M Outer jacket available colors: 20.Ω/M 24.9Ω/k Matte Black 65.9Ω/k Matte White YR46942 NEC: 5 500 52.4 74.0 33.6 sae sae sae.539 3.69 75 83% 6.3 53.5 CMR 000 304.8 47.0 73.5 as as as CEC: above above above CMG FT4 Inner jackets color coded (see chart) Outer jacket available color: Matte Black YR46943 NEC: 0 500 52.4 62.0 73.6 sae sae sae.796 20.22 75 83% 6.3 53.5 CMR 000 304.8 323.0 46.6 as as as CEC: above above above CMG FT4 Inner jackets color coded (see chart) Outer jacket available color: Matte Black 5.9 3.0 42 2.3 7.5 55 2.6 8.5 65 2.8 9.2 70 3.0 9.8 2 4.8 5.6 26 4.8 5.8 240 5. 6.7 270 5.4 7.7 300 5.7 8.6 325 5.9 9.4 350 6. 20.0 375 6.3 20.8 400 6.6 2.5 450 7.0 22.9 500 7.4 24.2 550 7.8 25.6 600 8.3 27.3 650 8.8 28.9 700 9.3 30.4 750 9.6 3.5 800 9.8 32. 862 0.0 32.8 870 0. 33. 900 0.2 33.5 950 0.3 33.8 000 0.5 34.4 500 3.0 42.6 2250 6.0 52.5 3000 8.5 60.7 BC = Bare Copper DCR = DC Resistance HDPE = High-density Polyethylene TC = Tinned Copper See Connector Reference Guide at www.belden.co for connector recoendations. Copatible White Sands Connectors F Crip (Cisco) MCX F Copression (Non CIsco) Connector ASFP MCXFP ASFPSLC Criper ACT-270 C47-020 CT-2R Stripper CPT-7538 CPT-7538-25 CPT-7538-25 Header Block MCXHEADERBK MCX Reoval Tool REMTOOL Color Code Chart: YR4694, YR46942 and YR46943 Cond. Color Cond. Color Red 6 Brown 2 Green 7 Orange 3 Blue 8 Gray 4 White 9 Violet 5 Yellow 0 Black 9

SDI Cable Belden SDI cables are the Broadcast industry s standard. They are ade with either solid copper conductors or highly stranded and copacted bare copper conductors with either highly crush resistant gas injected foa polyethylene or foa FEP insulations. Shields are either 00% coverage foil (Duoil ) or 95% coverage tinned copper braid. Belden leads the industry with 3 GHz sweep testing, but is now testing to 4.5 GHz. All cables eet SMPTE 292M for HDTV transissions, SMPTE 34M for widescreens and ITU-R-BT.60 for PAL transission standards in the international counity. These cables are available in both low tep and high tep jackets. RG-59/U and Double Braided RG-59/U Coax Lengths Conductor (stranding) Diaeter No. DCR Core OD Shielding OD Inch No. DCR Inch No. Ip. No. Vel. Prop. Capacitance pf/ pf/ MHz Attenuation 00 00 20 AWG Solid.032 Bare Copper Duoil (00% Coverage) + Tinned Copper Braid Shield (95% Coverage) Gas-injected Foa HDPE Insulation PVC Jacket (Available in 0 colors) SDI/HDTV 505A NEC: 500 52.4 7.0 8.0 20 AWG.45 3.68 Duoil.233 5.92 75 83% 6.3 53.5 Digital Video CMR 000 304.8 35.0 6.4 (solid) + 95% 75 C CEC: 5000 524.0 65.0 74.8.032" TC Braid CMG FT4 BC 3.8Ω/M 0.0Ω/M 2.5Ω/k 32.8Ω/k 500 ft. put-up available in Black, Red or Blue only. 5000 ft. put-up ay vary -0% to 0%. 000 ft. and 5000 ft. put-ups available in all ten colors: Black, Brown, Red, Orange, Yellow, Green, Blue, Purple, Gray or White. 22 AWG Stranded (7x29).03 Bare Copacted Copper Conductor TC Double Braid Shield (95% Coverage) Gas-injected Foa HDPE Insulation PVC Jacket (Matte Black, Red, Green, Blue, Yellow, White, Purple or Orange) High-Flex 505F NEC: 000 304.8 45.0 20.4 22 AWG.45 3.68 TC Double.242 6.5 75 80% 7.0 55.8 SDI/HDTV CM (7x29) Braid Video Patch CEC:.03" 94% Shield 75 C CM BCC Coverage 2.2Ω/M 2.4Ω/M 40.0Ω/k 7.8Ω/k Copacted conductor cobines ipedance unifority solid conductors and nick-resistance stranded conductor. BC = Bare Copper BCC = Bare Copacted Copper DCR = DC Resistance HDPE = High-density Polyethylene TC = Tinned Copper Suitable for Outdoor and Direct Burial applications..3.0 3.6.6 2.0 5.6 2. 7.7 2.4 0.9 3.0 67.5 2. 6.7 7.5 2. 6.9 88.5 2.2 7.2 00 2.3 7.6 35 2.7 8.9 43 2.8 9.2 80 3. 0.2 270 3.8 2.5 360 4.4 4.4 540 5.5 8.0 720 6.4 2.0 750 6.5 2.3 000 7.6 24.9 500 9.3 30.5 2000 0.9 35.8 2250.6 38. 3000 3.4 44.0 4500 6.4 53.8.2.7 3.6.5.6 5.6 2.0 7.7 2.4 0.9 3.0 67.5 2.4 7.9 7.5 2.5 8.2 88.5 2.8 9.2 00 3.0 9.8 35 3.5.5 43 3.6.8 80 4. 3.5 270 5. 6.7 360 6.0 9.7 540 7.4 24.3 720 8.7 28.5 750 8.9 29.2 000 0.5 34.5 500 3.3 43.6 2000 5.7 5.5 2250 6.9 55.4 3000 20.3 66.6 0

SDI Cable (continued) RG-59/U and Double Braided RG-59/U Coax Lengths Conductor (stranding) Diaeter No. DCR Core OD Shielding OD Inch No. DCR Inch No. Ip. No. Vel. Prop. Capacitance pf/ pf/ MHz Attenuation 00 00 20 AWG Solid.032 Bare Copper Conductor Duoil (00% Coverage) + Tinned Copper Braid Shield (95% Coverage) Plenu Foa FEP Insulation Flaarrest Jacket (Available in 0 colors) SDI/HDTV 506A NEC: 500 52.4 6.0 7.3 20 AWG.33 3.38 Duoil.96 4.93 75 84% 6. 52.8 Digital Video CMP 000 304.8 3.0 4. (solid) + 95% 75 C CEC:.032" TC Braid CMP FT6 BC 3.2Ω/M 00% Sweep tested. 5 MHz to 3 GHz. 0.0Ω/M 0.5Ω/k 32.8Ω/k 500 ft. put-up available in Black or Natural only. 000 ft. put-up available in all ten colors: Black, Brown, Red, Orange, Yellow, Green, Blue, Purple, Gray or Natural..3.0 3.6.6 2.0 0. 3.4 7.5 2.3 7.4 35 3.2 0.5 270 4.6 4.9 360 5.3 7.2 540 6.4 2.0 720 7.3 24.0 750 7.5 24.6 000 9.4 30.8 500 2.8 42.0 2250 7.5 57.4 3000 2.9 7.8 RG-6/U Coax 8 AWG Solid.040" Bare Copper Conductor Duoil (00% Coverage) + Tinned Copper Braid Shield (95% Coverage) Gas-injected Foa HDPE Insulation PVC Jacket (Available in 0 colors) SDI/HDTV 694A NEC: 500 52.4 22.5 0.2 8 AWG.80 4.57 Duoil.274 6.96 75 82% 6.2 53.2 Digital Video CMR 000 304.8 45.0 20.5 (solid) + 95% 75 C CEC: 4500 37.6 202.5 9.9.040" TC Braid CMG FT4 BC 2.8Ω/M 00% Sweep tested. 5 MHz to 3 GHz. 6.4Ω/M 9.2Ω/k 2.0Ω/k 500 ft. put-up available in Black only 000 ft. put-up available in Black, Brown, Red, Orange, Yellow, Green, Blue, Purple, Gray or White. 4500 ft. put-up available in Brown, Red, Blue, Violet, Gray, Black and Green. BC = Bare Copper DCR = DC Resistance FEP = Fluorinated Ethylene Propylene HDPE = High-density Polyethylene TC = Tinned Copper Copacted conductor cobines ipedance unifority solid conductor and nick-resistance stranded conductor..2.8 3.6.5.5 0.7 2.4 7.5.6 5.3 35 2. 6.9 270 3.0 9.7 360 3.4.3 540 4.3 3.9 720 4.9 6. 750 5.0 6.4 000 5.9 9.3 500 7.3 24.0 2250 9. 30.0 3000 0.7 35.0 4500 3.3 43.6

SDI Cable (continued) RG-6/U Coax Lengths Conductor (stranding) Diaeter No. DCR Core OD Shielding OD Inch No. DCR Inch No. Ip. No. Vel. Prop. Capacitance pf/ pf/ MHz Attenuation 00 00 9 AWG Stranded (7x27).040" Bare Copacted Copper Double Tinned Copper Braid Shield Gas-injected Foa HDPE Insulation PVC Jacket (Matte Black, Red, Green, Blue, Yellow, White or Violet) High Flex 694F NEC: 000 304.8 54.0 24.7 9 0.8 4.57 Double 93%.274 7.00 75 8% 6.2 53.2 SD/HDTV CMR AWG TC Braid Video Patch CEC: (7X27) 99% Total 75ºC CMG FT4.040" Coverage Miniu Return Loss: BC.7Ω.M 20dB (5-850 MHz) 8.5Ω/M 5.6Ω/k 5dB (850-4500MHz) 27.9Ω/k 00% Sweep tested. 5MHz to 4.5 GHz. t BC = Bare Copper DCR = DC Resistance HDPE = High-density Polyethylene TC = Tinned Copper Copacted conductor cobines ipedance unifority solid conductor and nick-resistance stranded conductor..2.7 3.6.5.6 0.7 2.3 7.5 2.0 6.6 35 2.8 9.2 270 4.0 3. 360 4.7 5.4 540 5.9 9.4 720 6.9 22.6 750 7.0 23.0 000 8.2 26.9 500 0.4 34. 2250 3.2 43.3 3000 5.6 5.2 4500 9.8 64.9 2

VoIP Cable Belden Data cables, the highest quality products in the industry, are ideal for equipent interconnects such as Voice Over Internet Protocols (VoIP). They are available in both Bonded-pair and Nonbonded-pair versions, Category 3 to Category 6 plenu or non-plenu. Enhanced Category 5e Bonded-pair UTP Cable Pairs Lengths Unit Wt. OD Inch DCR (Ω/ 00) DCR Unbal. (%) Cap. Unbal. (pf/ 00) Freq. (MHz) Atten. ( 00) PSUM NEXT (db) PSUM ACR ( 00) PSUM ELFEXT ( 00) Input Iped. RL (db) 24 AWG Bonded-Pairs Solid Bare Copper Conductors Rip Cord See Color Code Chart (below) Non-Plenu Polyolefin Insulation PVC Jacket (Red, Orange, White, Black, Yellow, Green, Blue, Purple, Light Gray or Gray) Rip Cord 700A NEC: 4 U-000 U-304.8 22.0 0.0.200 5.08 9.0 3.0 66.0 CM 000 304.8 22.0 0.0 CEC: 640 500.0 36. 6.4 CM 3000 94.4 63.0 28.6 3280 000.0 72.2 32.8 000 ft. put-up not available in Gray. 640 ft. available in Lt. Gray or Blue only. 3000 ft. put-up available in Red, Blue, White or Lt. Gray only. 3280 ft. available in Lt. Gray only. Jacket sequentially arked at 2 ft. intervals. U.S. Patents 5,606,5 and 5,734,26 Third party verified to TIA/EIA-568-B.2, Category 5e Banana Peel Coposite Bonded-pair Category 5e UTP Cable 24 AWG Bonded-pairs Solid Bare Copper Conductors Spline See Color Code Chart (below) Non-Plenu Polyolefin Insulation PVC Jacket (Red, Orange, White, Black, Yellow, Green, Blue, Purple, Light Gray or Gray) 700S4 NEC 6 U-000 U-304.8 22.0 0.0.204 5.8 9.0 3.0 66.0 CMR 000 304.8 22.0 0.0 Bundled CEC: 640 500.0 36. 6.4.492 2.50 CMG FT4 3000 94.4 63.0 28.6 3280 000.0 72.2 32.8 000 ft. put-up not available in Gray. 640 ft. available in Lt. Gray or Blue only. 3000 ft. put-up available in Red, Blue, White or Lt. Gray only. 3280 ft. available in Lt. Gray only. U.S. Patents 5,606,5; 5,734,26; 7,049, 523 Third party verified to ANSI/TIA/EIA 568-B.2-, Category 5e 24 AWG Bonded-pairs Solid Bare Copper Conductors Spline Filler Ripcord See Color Code Chart (below) Non-Plenu Polyolefin Insulation PVC Inner Jacket (Available in Light Blue or Gray) No Overall Jacket 700S6 NEC: 24 500 52.4 77.5 35.9.204 5.8 9.0 3.0 66.0 u CMR 000 304.8 49.0 67.65 Bundled CEC:.600 5.24 CMG FT4 U.S. Patents 5,606,5; 5,734,26; 7, 049, 523 Third party verified to ANSI/TIA/EIA 568-B.2-, Category 5e ACR = Attentuation Crosstalk Ratio DCR = DC Resistance ELFEXT = Equal Level Far-end Crosstalk NEXT = Near-end Crosstalk PSUM = PowerSu RL = Return Loss UTP = Unshielded Twisted Pair(s) 4 8 0 6 25 3.25 62.5 00 55 200 250 350 4 8 0 6 25 3.25 62.5 00 55 200 250 350 4 8 0 6 25 3.25 62.5 00 55 200 250 350 2.0 4.0 5.7 6.4 8. 0.3.6 6.8 2.7 27.7 32.0 36.4 44.3 65.3 56.3 5.8 50.3 47.3 44.3 42.9 38.4 35.3 32.5 30.8 29.3 27.2 63.3 52.3 46. 43.9 39. 34. 3.3 2.6 7. 4.7 3.0 60.8 48.8 42.7 40.8 36.7 32.8 30.9 24.9 20.8 6.9 4.7 2.8 9.9 00±8 00±8 00±20 Color Codes: Coposite UTP Pair 2.0 4.0 5.7 6.4 8. 0.3.6 6.8 2.7 27.7 32.0 36.4 44.3 2.0 4.0 5.7 6.4 8. 0.3.6 6.8 2.7 27.7 32.0 36.4 44.3 65.3 56.3 5.8 50.3 47.3 44.3 42.9 38.4 35.3 32.5 30.8 29.3 27.2 65.3 56.3 5.8 50.3 47.3 44.3 42.9 38.4 35.3 32.5 30.8 29.3 27.2 63.3 52.3 46. 43.9 39. 34. 3.3 2.6 7. 4.7 3.0 63.3 52.3 46. 43.9 39. 34. 3.3 2.6 7. 4.7 3.0 60.8 48.8 42.7 40.8 36.7 32.8 30.9 24.9 20.8 6.9 4.7 2.8 9.9 60.8 48.8 42.7 40.8 36.7 32.8 30.9 24.9 20.8 6.9 4.7 2.8 9.9 Color Cobination White/Blue Stripe & Blue 00±8 00±8 00±20 00±8 00±8 00±20 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green 4 White/Brown Stripe & Brown 20.0 23.0 24.5 24.3 23.6 2.5 20. 9.0 9.0 8.0 7.0 20.0 23.0 24.5 24.3 23.6 2.5 20. 9.0 9.0 8.0 7.0 20.0 23.0 24.5 24.3 23.6 2.5 20. 9.0 9.0 8.0 7.0 3

VoIP Cable (continued) Enhanced Category 6 Bonded-pair UTP Cable Pairs Lengths Unit Wt. OD Inch DCR (Ω/ 00) DCR Unbal. (%) Cap. Unbal. (pf/ 00) Freq. (MHz) Atten. ( 00) PSUM NEXT (db) PSUM ACR ( 00) PSUM ELFEXT ( 00) Input Iped. RL (db) 23 AWG Bonded-Pairs Solid Bare Copper Conductors Patented E-Spline Center Meber Rip Cord See Color Code Chart (below) Non-Plenu Polyolefin Insulation PVC Jacket (Available in Red, Orange, Yellow, Green, Blue, Black, White or Gray) 785A NEC: 4 000 304.8 38.0 7.2.227 5.77 8.2 3.0 65.6 CMR A-000 A-304.8 47.0 2.3 x x CEC:.35 8.00 CMR FT4 Jacket sequentially arked at 2 ft. intervals. U.S. Patents 5,606,5; 5,734,26; 5,789,7 and 6,297,454-B Third party verified to TIA/EIA-568-B.2-, Category 6 Plenu FEP Teflon Insulation Flaarrest Jacket (Available in Red, Orange, Yellow, Green, Blue, Black, White or Gray) 7852A NEC: 4 000 304.8 40.0 8..28 5.54 8.2 3.0 65.6 CMP A-000 A-304.8 49.0 22.2 x x CEC:.290 7.37 CMP FT6 A-000 ft. put-up not available in Red. U.S. Patents 5,606,5; 5,734,26; 5,789,7 and 6,297,454-B Third party verified to TIA/EIA-568-B.2-, Category 6 Jacket sequentially arked at 2 ft. intervals. Category 6 Nonbonded-pair UTP Cable Plenu FEP Teflon Insulation Flaarrest Jacket (Available in Red, Orange, Yellow, Green, Blue, Purple, Gray, Natural or Black) Rip Cord 7882A NEC: 4 000 304.8 29.0 3.2.224 5.69 8.2 3.0 08.2 CMP A-000 A-304.8 32.0 4.5 CEC: CMP FT6 Jacket sequentially arked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2-, Category 6 ACR = Attentuation Crosstalk Ratio DCR = DC Resistance ELFEXT = Equal Level Far-end Crosstalk FEP = Flourinated Ethylene-propylene NEXT = Near-end Crosstalk PSUM = PowerSu RL = Return Loss UTP = Unshielded Twisted Pair(s) *PSUM ACR>0 is guaranteed to 460 MHz. 0 3.25 62.5 00 55 200 250 350 400 500 550 600 0 3.25 62.5 00 55 200 250 350 400 500 550 600 0 20 3.25 62.5 00 200 250.9 5.7 0.2 4.7 8.9 23.9 27.5 3.2 37.7 40.6 46.2 48.8 5.4.9 5.7 0.2 4.7 8.9 23.9 27.5 3.2 37.7 40.6 46.2 48.8 5.4 2.0 6.0 8.5 0.7 5.4 9.8 29.0 32.8 80.3 65.3 57.9 53.4 50.3 47.5 45.8 44.3 40.2 39.3 37.8 37.2 36.6 80.3 65.3 57.9 53.4 50.3 47.5 45.8 44.3 40.2 39.3 37.8 37.2 36.6 72.3 57.3 52.8 49.9 45.4 42.3 37.8 36.3 78.5 59.6 47.7 38.7 3.4 23.5 8.3 3.2 4.5 0.6 >0* 78.5 59.6 47.7 38.7 3.4 23.5 8.3 3.2 4.5 0.6 >0* 70.3 5.3 44.3 39.2 30.0 22.5 8.8 3.5 70.8 50.8 40.9 34.9 30.8 27.0 24.8 22.8 9.9 8.8 6.8 6.0 5.2 70.8 50.8 40.9 34.9 30.8 27.0 24.8 22.8 9.9 8.8 6.8 6.0 5.2 64.8 44.8 38.7 34.9 28.8 24.8 8.7 6.8 00±20 00±20 00±32 20.0 22.8 2.7 20.5 9.8 9.5 8.4 8.0 7.6 20.0 22.8 2.7 20.5 9.8 9.5 8.4 8.0 7.6 20.0 23.6 2.5 20. 8.0 7.3 Color Codes: Coposite UTP Pair Color Cobination White/Blue Stripe & Blue 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green 4 White/Brown Stripe & Brown 4

VoIP Cable (continued) Bundled Category 6 Nonbonded-pair UTP Cable Pairs Lengths Unit Wt. 23 AWG Solid Bare Copper Conductors Twisted Pairs Central Rod Filler Rip Cord See Color Code Chart (below) Non-Plenu Polyolefin Insulation PVC Jacket (Available in Red, Orange, Yellow, Green, Blue, Purple, Gray, White or Black) Rip Cord OD 788A NEC: 4 000 304.8 30.0 3.6.24 6.2 8.2 3.0 08.2 CMR A-000 A-304.8 33.0 5.0 CEC: CMR Jacket sequentially arked at 2 ft. intervals. Features Descending Length Marking. Third party verified to TIA/EIA-568-B.2-, Category 6 ACR = Attenuation Crosstalk Ratio DCR = DC Resistance ELFEXT = Equal Level Far-end Crosstalk NEXT = Near-end Crosstalk PSUM = Power Su RL = Return Loss UTP = Unshielded Twisted Pair(s) Inch DCR (Ω/ 00) DCR Unbal. (%) Cap. Unbal. (pf/ 00) Freq. (MHz) 0 20 3.25 62.5 00 200 250 Atten. ( 00) 2.0 6.0 8.5 0.7 5.4 9.8 29.0 32.8 PSUM NEXT (db) 72.3 57.3 52.8 49.9 45.4 42.3 37.8 36.3 PSUM ACR ( 00) 70.3 5.3 44.3 39.2 30.0 22.5 8.8 3.5 PSUM ELFEXT ( 00) 64.8 44.8 38.8 34.9 28.9 24.8 8.8 6.8 Input Iped. 00±32 RL (db) 20.0 23.6 2.5 20. 8.0 7.3 Color Codes: UTP Cable Pair Color Cobination White/Blue Stripe & Blue 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green 4 White/Brown Stripe & Brown 5

Digital and Analog Audio Cable Single- and Double-Pair Cables Lengths Color Pairs Code Insulation Thickness Inch Jacket Thickness Inch OD Inch Capacitance * pf/ * pf/ ** pf/ ** pf/ 6 22 AWG Stranded (7x30) TC Conductors Twisted Pair Overall Beldfoil Shield (00% Coverage) 22 AWG Stranded TC Drain Wire Polypropylene Insulation Paper Wrap Gray or Black PVC Jacket 300V RMS 75 C 845 NEC: Black, 00 30.5 2.3..008.20.020.5.38 3.5 34 67 220 CMR Red U-500 U-52.4 8.5 3.9 CEC: 500 52.4 8.0 3.6 Z-Fold CMG FT4 U-000 U-304.8 6.0 7.2 000 304.8 6.0 7.2 Analog Audio Cable 00 ft. put-up available in Black only. Unique paper separator facilitates jacket stripping. Polypropylene Insulation PVC Jacket (Available in Brown, Red, Orange, Yellow, Green, Blue, Purple, Gray, White or Black) 300V RMS 75 C 945 NEC: Black, U-500 U-52.4 8.0 3.6.008.20.020.5.35 3.43 34 67 220 CMR Red 500 52.4 8.0 3.6 CEC: T-000 T-304.8 8.0 8.2 CMG FT4 U-000 U-304.8 6.0 7.3 Analog Audio Cable U-500 ft., 500 ft. and T-000 ft. put-ups available in Gray only. 5000 524.0 70.0 3.8 The jacket and shield are bonded so both can be reoved on autoatic stripping equipent. Drain wire is inside foil shield. 22 AWG Stranded (7x30) TC Conductors Dual Twisted Pairs Overall Beldfoil Shield (00% Coverage) 22 AWG Stranded TC Drain Wire Polyolefin Insulation PVC Jacket in Zip-Cord Construction (Red & Green, Red & Gray, Red & Black or Red & Purple) 300V RMS 05 C 945D NEC: 2 Black, U-000 U-304.8 29.0 3.2.008.20.020.5.35 3.43 34 67 220 CMR Red 2000 620.8 62.0 28. x x CEC:.270 6.86 CMG FT4 Analog Audio Cable 2000 ft. put-up available in Red & Green only. The jacket and shield are bonded so both can be reoved on autoatic stripping equipent. Drain wire is inside foil shield. Plenu FEP Insulation White Flaarrest Jacket in Zip-Cord Construction 300V RMS 60 C 945DP NEC: 2 Black & 000 304.8 26.0.8.007.8.07.43.27 3.23 35 5 67 220 u CMP Red, x x CEC: Black &.269 6.83 CMP FT6 White Analog Audio Cable The jacket and shield are bonded so both can be reoved on autoatic stripping equipent. Drain wire is inside foil shield. Color Lengths Pairs Code 24 AWG Stranded (7x32) TC Conductors Dual Twisted Pairs Overall Beldfoil Shield (00% Coverage) 24 AWG Drain Wire Datalene Insulation Gray or Purple PVC Jacket 60 C 800B NEC: Black, 500 52.4 8.0 3.6 23.7Ω/M 8.9Ω/M.77 4.57 0 76% 2 39 26 85 CMG Red U-000 U-304.8 7.0 7.7 77.7Ω/k 62.0Ω/k CEC: 000 304.8 6.0 7.3 CMG FT4 5000 524.0 90.0 40.8 Digital Audio Cable 500 ft. put-up available in Gray only. 5000 ft. put-up available in Purple only. The jacket and shield are bonded so both can be reoved with autoatic stripping equipent. 24 AWG Stranded (7x32) TC Conductors Dual Twisted Pairs Individual Pairs Shielded with Beldfoil Shield (00% Coverage) 24 AWG Drain Wire Datalene Insulation Purple PVC Jacket in Zip-Cord Construction 60 C 802B NEC: 2 Black, 500 52.4 6.5 7.5 23.7Ω/M 8.9Ω/M.80 4.57 0 76% 2 39 26 85 CMG Red U-000 U-304.8 35.0 5.9 77.7Ω/k 62.0Ω/k x x CEC: 000 304.8 37.0 6.8.360 9.4 CMG FT4 Digital Audio Cable The jacket and shield are bonded so both can be reoved with autoatic stripping equipent. DCR = DC Resistance FEP = Flourinated Ethylene-propylene TC = Tinned Copper * Capacitance between conductors. ** Capacitance between one conductor and the other conductors connected to shield. Cond. No. DCR Shield OD Inch No. Ip. No. Vel. Prop. * pf/ No. Capacitance * pf/ ** pf/ ** pf/

DS-3 and DS-4 Interconnect and Cross-connect Coax Cable The cables depicted below are representative an extensive range Digital Sign DS-3 and DS-4 cables fered by Belden. These cables are fered with 26 AWG solid silver-plated copper conductors or 20 AWG solid bare copper conductors and include either Beldfoil and tinned copper braid shields or tinned copper/bare copper double braid shields. Insulations are foa HDPE, foa FEP or gas-injected FHDPE; jackets are either PVC or Flaarrest. Soe Siaese, bundled and essengered versions also are available, as well as custo designs. Consult Belden s ecatalog at www.belden.co or contact your local sales representative for ore inforation. Cond. Lengths 26 AWG Solid.06 (.40) Silver-plated Copper Conductor(s) Beldfoil + Tinned Copper Braid Shield (93% Coverage) Foa HDPE Insulation Overall Gray PVC Jacket (Multiple coaxes feature inner Gray PVC jackets w/printed nos. for circuit ID) 735A* NEC: 500 52.4 6.5 2.9 26 AWG.077.96 Beldfoil.29 3.28 75 76% 7.7 58. CMR 000 304.8 2.0 5.5 (solid) + 93% TC CEC:.06" Braid 00% Sweep tested. CMG FT4 SPC 5.3Ω/M RL: 30dB in. at 5 MHz to 95 MHz. 4.0Ω/M 7.4Ω/k 34.5Ω/k 20 AWG Solid.032 (.8) Silver-plated Copper Conductor(s) Beldfoil (00% Coverage) + Tinned Copper Braid Shield (85% Coverage) Gas-injected FHDPE Insulation Gray PVC Jacket 734D* NEC: 500 52.4 6.0 7.3 20 AWG.48 3.76 Beldfoil.235 5.97 75 80% 6.8 55. CMR 000 304.8 36.0 6.3 (solid) + 85% TC CEC:.032" Braid 00% Sweep tested. CMG FT4 SPC 2.4Ω/M RL: 30dB in. at 5 MHz to 95 MHz. 0.0Ω/M 7.9Ω/k Coplies with Telcordia Specification 32.8Ω/k GR-39-CORE. 20 AWG Solid.032 (.8) Bare Copper Conductor(s) Beldfoil (00% Coverage) + Tinned Copper Braid Shield (85% Coverage) Gas-injected FHDPE Insulation Gray PVC Jacket Conductor (stranding) Diaeter No. DCR Core OD 734A* NEC: 500 52.4 6.0 7.3 20 AWG.48 3.76 Beldfoil.235 5.97 75 80% 6.8 55. CMR 000 304.8 35.0 5.9 (solid) + 85% TC CEC:.032" BC Braid CMG FT4 0.0Ω/M 2.4Ω/M 32.8Ω/k 7.9Ω/k BC = Bare Copper DCR = DC Resistance FEP = Fluorinated Ethylene Propylene FHDPE = Foa High-density Polyethylene HDPE = High-density Polyethylene TC = Tinned Copper See chart on page 6.58 for axiu transission distances. *Lucent Technologies reference specification. Belden equivalent. Miniu return loss @ 55 NHz to 95 MHz= -35 db Inch Shielding No. DCR OD Inch No. Ip. No. Vel. Prop. Capacitance pf/ pf/ 00% Sweep tested. RL: 30dB in. at 5 MHz to 95 MHz. Non-plenu versions coply with Telcordia Specification GR-39-CORE. Attenuation Stand. Signal (Mb/s) MHz 00 00 2.0.6 2.0 CEPT-.0.6 2.0 CEPT-2 4.2. 3.6 0 5.0.2 3.9 20 0.0.7 5.6 CEPT-3 7.2 2.2 7.2 DS-3 22.4 2.5 8.2 STS- 25.9 2.7 8.9 89.472 44.7 3.6.8 00 50.0 3.8 2.5 CEPT-4 69.6 4.5 4.8 STS-3 77.8 4.8 5.7 200 00.0 5.5 8.0 DS-4 37. 6.4 2.0 400 200.0 7.8 25.6 2.0.3.0 CEPT-.0.3.0 CEPT-2 4.2.5.6 0 5.0.6 2.0 20 0.0.8 2.6 CEPT-3 7.2.0 3.3 DS-3 22.4. 3.6 STS- 25.9.2 3.9 89.472 44.7.6 5.3 00 50.0.7 5.6 CEPT-4 69.6 2.0 6.6 STS-3 77.8 2. 6.9 200 00.0 2.5 8.2 DS-4 37. 2.9 9.5 400 200.0 3.6.8 2.0.3.0 CEPT-.0.3.0 CEPT-2 4.2.5.6 0 5.0.6 2.0 20 0.0.8 2.6 CEPT-3 7.2.0 3.3 DS-3 22.4. 3.6 STS- 25.9.2 3.9 89.472 44.7.6 5.3 00 50.0.7 5.6 CEPT-4 69.6 2.0 6.5 STS-3 77.8 2. 6.9 200 00.0 2.5 8.2 DS-4 37. 2.9 9.5 400 200.0 3.6.8 7

Optical Fiber Cable Tight Buffer Riser & Plenu Rated Applications Patch panels Workstation equipent connections Horizontal distribution in open fice environents Product Interconnect Cables are designed for low fiber-count preises environents. They are sall and very flexible, aking the ideal for confined spaces. Their aesthetic appearance akes these cables suitable for use in open fice environents. Available in or 2 fibers. One sub-unit is arked to perit easy identification transit and receive fibers. Length arkings to facilitate installation. Jacket Material Tight Buffer Strength Meber Color Code (Tight Buffer) PVC PVC Araid Yarn Per EIA/TIA 598-A, see page 0.2 Jacket Color Single-ode Yellow 62.5/25 μ Orange 50/25 μ / Gbe Orange 50/25 μ / 0 Gbe Aqua Specifications Teperature Range Storage Operating Crush Resistance (EIA-455-4) Ipact Resistance (EIA-455-25) Cyclic Flexing (EIA-455-04) Bend Radius Installation Long Ter -40 to +70 C -20 to +70 C 200 N/c 20 Ipacts @.0 N- 2000 cycles, in. 5 x OD 0 x OD Optical Specifications See page 0.2 Fiber Bundle Detail 2.9 (.4 in.) 900 Micron Buffered Fiber SIMPLEX Jacket 5.9 (.233 in.) DUPLEX Ratings Riser UL OFNR cul OFN FT4 Flae Resistance UL 666 Plenu UL OFNP cul OFN FT6 Flae Resistance NFPA 262 Fibers 62.5 / 25µ Std. / Gbe 50 / 25µ Std. / Gbe Belden Nuber 50 / 25µ 0 Gbe 300M Single-ode Enhanced Outside Diaeter Inch /000 Weight /k Install Load N Interconnect Cable Series Riser (NEC/CEC OFNR/OFN FT4) M972 M9A00 M9C00 M9W00 0.4 2.9 6 9 90 400 2 M9695 M9A002 M9C002 M9W002 0. x 0.23 2.9 x 5.9 2 8 80 80 Plenu (NEC/CEC OFNP/OFN FT6) M98086 M9A003 M9C003 M9W003 0.4 2.9 6 9 90 400 2 M9699 M9A004 M9C004 M9W004 0. x 0.23 2.9 x 5.9 3 9 80 80 All optical fiber products can be supplied in copliance with RoHS regulations. Please contact Custoer Service for ore details. 8

Technical Inforation Data Rate: Spec: Application: 43 Mb/s SMPTE 259M Coposite NTSC 77 Mb/s 270 Mb/s 360 Mb/s 540 Mb/s.5 Gb/s ITU-R BT. 60 Coposite PAL SMPTE 259M Coponent Video SMPTE 259M Coponent Widescreen SMPTE 344M* Coponent Widescreen SMPTE 252M 505A 430 436 320 402 00 338 960 293 790 24 300 9 505F 200 366 07 326 857 26 732 223 588 79 225 69 506A 360 45 200 366 940 286 80 247 670 204 270 82 694A 760 536 620 494 360 45 80 360 970 296 370 3 7855A 2220 677 2000 60 670 509 460 445 20 369 470 43 *Values proposed at tie printing. The serial digital interconnect standards are designed to operate where the signal loss at /2 the clock frequency does not exceed the approxiate loss values listed below. The axiu length values shown are based on typical attentuation values for the cables listed and the following criteria: Maxiu length = 30 db loss at /2 the clock frequency: SMPTE 259M, PAL, Widescreen. Maxiu length = 20 db loss at /2 the clock frequency: SMPTE 292M. The bit error rate (BER) can vary draatically as the calculated distances are approached. BER is dependent on receiver design and the losses the actual coax used. Distribution and routing equipent anufacturers should be contacted to verify their axiu recoended transission. HDTV Return Loss Headroo (694A) Return Loss (db) 0-0 -20-30 -40-50 SMPTE Recoended Return Loss Liit Belden Return Loss Specification Liit -60 Typical Return Loss SMPTE 259M -70 SMPTE 292M (Beyond Industry s) 080p* -80 0 360 500 500 3000 3000 4500 4500 Frequency (MHz) Typical Maxiu Cabling Distances Data Rate: DS-3 (44.746 Mb/s) STS- (5.86 Mb/s) DS-4NA (CEPT-4) (39.264 Mb/s) STS-3 (55.520 Mb/s) DS-4 (274.76 Mb/s) Belden Trade Interconnect X-Connect Interconnect X-Connect Interconnect X-Connect Interconnect X-Connect Interconnect X-Connect 735A Series 225 ft. 2 ft. 20 ft. 20 ft. 25 ft. 3 ft. 20 ft. ft. 90 ft. 8 ft. (68) (6) (64) (6) (38) (4) (37) (3) (27) (2) 734D Series 450 ft. 43 ft. 420 ft. 40 ft. 250 ft. 24 ft. 240 ft. 22 ft. 80 ft. 7 ft. (37) (3) (28) (2) (76) (7) (73) (6) (55) (5) 734A Series 435 ft. 43 ft. 40 ft. 40 ft. 240 ft. 24 ft. 225 ft. 22 ft. 70 ft. 7 ft. (32) (3) (25) (2) (73) (7) (68) (8) (52) (5) DS = Digital Signal STS = Synchronous Transission Signal CEPT = European Conference Postal and Telecounications Adinistrations Please note: The signal loss budget for individual installations will affect the exact transission distance. 9

Duobond Plus Shielding Flex Cycles Transfer Ipedence (OHMS/eter) 000 00. FLEX CYCLES.0 0 00 000 Frequency (MHz) Duobond II Duobond IV Duobond III Duobond Plus 000 00. BEFORE FLEX CYCLES.0 0 00 000 Frequency (MHz) Duobond II Duobond IV Duobond III Duobond Plus Transfer Ipedence (OHMS/eter) 000 00. AFTER 86,000 FLEX CYCLES.0 0 00 000 Frequency (MHz) Duobond II Duobond IV Duobond III Duobond Plus RL (db) -0-5 -20-25 -30-35 Belden Data Cable Return Loss Initial Installed Cat 5e Spec -40 0 50 00 50 200 250 300 350 Frequency (MHz) RL (db) 5 4 3 2 0 9 8 7 6 5 4 3 2 0 - -2-3 -4-5 -6-7 Data Pairs Blue Orange Belden Data Cable Return Loss (20-00 MHz) Initial Green Brown Installed 20 Belden Technical Support.800.BELDEN. www.belden.co HEB00 Copyright 2006, Belden Inc.