Installation instructions for Series NRX INCOM communications adapter module



Similar documents
Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

8 Channel Status Input Panel model SIP-8

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Advantium 2 Plus Alarm

Installation Instructions for EHD, EDB, EDS, ED, EDH, EDC, FDB, FD, HFD, FDC, HFDDC Circuit Breakers and Molded Case Switches

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

MCR1900 Media Converter 19-Slot Chassis

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

Sunny Boy Accessories SMA POWER BALANCER

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

EMR-3000 Quick Start Guide. IB E Rev. A. Contents. Description

SECTION LOW VOLTAGE LIGHTING CONTROLS

INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

HP UPS R1500 Generation 3

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

INSTALLATION INSTRUCTIONS

Application/Connection Examples

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

LIEBERT VNSA Installation Sheet

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Crow Limited Warranty. Print Version 017

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

StorTrends 3400 Hardware Guide for Onsite Support

PXL-250: Network Wiring

Installation and Operation Guide PD4600 Series Converter Replacement

Medium voltage VCP-W MR2 (integral racking)

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Mobile Data Power Model: MDP-25

Operation and Installation Manual

AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED. Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

VX 2400 Dimmer User's Manual

UniStream CPU-for-Panel

Eaton Generator and Automatic Transfer Switch Generator Start Connection Diagrams

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

BACnet Automation Interface Module (Network Version)

ELCOMPONENT LTD. User Manual

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

T7560A,B,C Digital Wall Module

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

Backup Scanner Module

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Single Station Remote Alarm

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

OPL BASIC. Dosing System for Professional Laundry machines. Contents

EMBEDDED ACCESS CONTROL Hardware Installation Guide

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Troubleshooting and Diagnostics

for DNE-K07 Reference and Installation Manual

HP R12000 and R18000 DirectFlow UPS User Guide

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

Perle Protocol Transparent Media Converter Modules

Keep it Simple Timing

User manual Compact Web PLC WP240 series IEC-line

LocoNet, the Digitrax Difference

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Cisco Unified IP Conference Phone 8831 Installation

Fire Fighter Phone System Installation Instructions

Installation, Operation & Service Manual

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

Instructions for Connecting PETROSMART EZ Control Systems To Wayne Electronic Dispensers With/Without CAT CREDIT CARD MODULES

L5354 ControlNet Communications Interface

Co-location Interconnect Power Panel (CIPP) Installation Guide

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

How To Install A Power Supply (Uplast) With A Battery Pack

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Installation Guide Solar Connect-11

How to read this guide

WIRELESS HOME ALARM SYSTEM (WHA1)

Bypass transfer switch mechanisms

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

ISHIDA BC Scale to Scale Communications

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

The power module is Feature Number 8800-F2-901.

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Transcription:

4000 NRX RF DRAWOUT SUBTITLE IMAGE (12/15/2010) Effective July 2015 Supersedes October 2010 IL01301033EH04 Installation instructions for Series NRX INCOM communications adapter module Instructions apply to: 1600 NRX SUB-TITLE IMAGE (12/15/2010) Series NRX, Type NF Frame ANSI, UL1066, UL489/IEC IZMX16, IZM91 WARNING (1) ONLY QUALIFIED ELECTRICAL PERSONNEL SHOULD BE PERMITTED TO WORK ON THE EQUIPMENT. (2) ALWAYS DE-ENERGIZE PRIMARY AND SECONDARY CIRCUITS IF A CIRCUIT BREAKER CANNOT BE REMOVED TO A SAFE WORK LOCATION. (3) DRAWOUT CIRCUIT BREAKERS SHOULD BE LEVERED (RACKED) OUT TO THE DISCONNECT POSITION. (4) ALL CIRCUIT BREAKERS SHOULD BE SWITCHED TO THE OFF POSITION AND MECHANISM SPRINGS DISCHARGED. FAILURE TO FOLLOW THESE STEPS FOR ALL PROCEDURES DESCRIBED IN THIS INSTRUCTION LEAFLET COULD RESULT IN DEATH, BODILY INJURY, OR PROPERTY DAMAGE. WARNING THE INSTRUCTIONS CONTAINED IN THIS IL AND ON PRODUCT LABELS HAVE TO BE FOLLOWED. OBSERVE THE FIVE SAFETY RULES: DISCONNECTING ENSURE THAT DEVICES CANNOT BE ACCIDENTALLY RESTARTED VERIFY ISOLATION FROM THE SUPPLY EARTHING AND SHORT-CIRCUITING COVERING OR PROVIDING BARRIERS TO ADJACENT LIVE PARTS DISCONNECT THE EQUIPMENT FROM THE SUPPLY. USE ONLY AUTHORIZED SPARE PARTS IN THE REPAIR OF THE EQUIPMENT. THE SPECIFIED MAINTENANCE INTERVALS AS WELL AS THE INSTRUCTIONS FOR REPAIR AND EXCHANGE MUST BE STRICTLY ADHERED TO PREVENT INJURY TO PERSONNEL AND DAMAGE TO THE SWITCHBOARD. Series NRX, Type RF Frame IEC, IZMX40 Section 1: General information The Series NRXE INCOME Communications Adapter Module (ICAM) (Figure 1) is an accessory that will operate as a communicating device in conjunction with a compatible Series NRX trip unit/breaker in a master communications network (Figure 2). The INCOM network sends a burst of data as a 92 115.2 khz carrier signal at a 9600 baud rate over twisted pair conductors to interconnect the many devices comprising the network. These bursts of data can be captured and used in a variety of ways depending upon the manner in which the master computer program is configured. For example, all the settings can be viewed via the master computer. Also, the data for the individual phase current values is available on the network. The software will select the appropriate data, decode it, and display it in a useful manner. Following an overcurrent trip operation, the cause of trip, the value, and the phase or ground current responsible for the trip are available on the network.

Effective July 2015 The INCOM communications adapter module is a slave device and as such requires a master device for control command initiation. Each INCOM communications adapter module provides: Circuit breaker Open/Close/Reset control Series NRX trip unit source/residual ground selection Flashing Status LED, indicating module has power INCOM communication Enable/Disable selection jumper for remote Open/Close control DIN rail mounting (11 mm H, 28 mm W DIN rail minimum requirement) Input power for module from 24 Vdc Figure 1. Series NRX INCOM Communications Adapter Module Master Device ICAM Module 1 Series NRX Breaker ICAM Module 2 Communications Network Series NRX Breaker ICAM Module 3 Series NRX Breaker Figure 2. INCOM Communications Adapter Modules in an INCOM Network The INCOM communications adapter module is designed to be installed, operated, and maintained by adequately trained people. These instructions do not cover all details or variations of the equipment for its storage, delivery, installation, checkout, safe operation, or maintenance. If you have any questions or need additional information or instructions, please contact your local Eaton representative or visit www.eaton.com. Section 2: Installation of INCOM communications adapter module The following steps outline the installation procedure for an INCOM communications adapter module in a drawout circuit breaker configuration only. For fixed-mounted circuit breakers, a separate DIN rail mounting configuration is preferred. Consult the customer support center for additional information. The following tools should be available: #T-15 Torx Small flat blade screwdriver NNotes: Many illustrations use the NF Frame circuit breaker for illustrative purposes only. The RF Frame circuit breaker is handled in a similar fashion. 2 EATON CORPORATION www.eaton.com

Effective July 2015 For drawout circuit breakers, secondary terminal blocks as well as the INCOM communications adapter module are DIN rail mounted on the top front portion of the drawout cassette. The module is designed to install or replace the four terminal blocks (eight contacts in total) at secondary contacts 19 through 26 for both the NF and RF frames. Refer to the master connection diagram TD01301014E. For additional information relative to secondary terminal block installation and/or removal beyond that which is presented in this section, refer to IL01301037E. Proceed with the following seven steps: Step 1s: Using a T-15 Torx, remove the four mounting screws holding the terminal block alignment bracket in place. Step 3s: Remove the terminal block in location 19/20 by inserting a small screwdriver in the recessed area in the top front of the terminal block as shown, and gently pry down to release and remove the block from the DIN rail. Figure 5. Step 3 Step 4s: Repeat the same procedure performed in Step 3 to remove terminal blocks at locations 21/22, 23/24, and 25/26. NNote: The extra DIN rail mounting screw located in the space where the four terminal blocks were mounted may need to be removed to allow the unit s pogo pin ground connection to properly hit the metal DIN rail. Figure 3. Step 1 Step 2s: Carefully slide the alignment bracket out from between any mounted terminal blocks, and put it aside with its mounting hardware for re-installment after the communications adapter module is connected to the DIN rail. Mounting Screw Figure 6. Step 4 Figure 4. Step 2 EATON CORPORATION www.eaton.com 3

Effective July 2015 Step 5s: Tilt the communications module forward to engage the upper part of the DIN rail, and then snap it back into the DIN rail for complete engagement. Step 7s: A mounted communications module appears as shown and the installation procedure is complete. The module can now be wired with the information presented in Section 3. Figure 7. Step 5 Step 6s: Carefully slide the terminal block alignment bracket back into position. Before securing the bracket in place, inspect it from the bottom to ensure that the teeth on the bracket separate each individual terminal block. One installed terminal block should only be visible between two teeth when the alignment bracket is properly positioned. Secure the terminal block alignment bracket using the four screws previously removed. Hand tighten the four mounting screws. Figure 8. Step 6 Figure 9. Step 7 Section 3: Basic wiring rules The following basic rules apply given a system consisting of a single daisy-chained main cable link between master and slave devices (Figure 2). For more complex considerations including star configurations, please refer to the INCOM wiring specification TD17513. 1. Recommended cable specifications: Eaton cable catalog #IMPCABLE, Style #2A95705G01 Belden 9463 cable family Identical Commscope or Quabbin cables 2. The maximum system capacity is 10,000 feet of communications cable and 1000 slave devices. 3. Non-terminated taps, up to 200 feet in length, off the main link are permitted, but add to the total cable length. 4. Make sure there is a twisted wire pair present that is intended for INCOM network use. Use shielded twisted pair wire to connect each slave device to the INCOM network, daisy-chain style. The polarity of the twisted pair is not important. 5. Ferrules for use in double connection point daisy-chain wiring are available. Weidmuller part 9004310000 (2 #18AWG). 4 EATON CORPORATION www.eaton.com

Effective July 2015 Section 4: INCOM communications adapter module connections m WARNING ALL APPLICABLE SAFETY CODES, SAFETY STANDARDS, AND SAFETY REGULATIONS MUST BE STRICTLY ADHERED TO WHEN INSTALLING, OPERATING, OR MAINTAINING THIS EQUIPMENT. FAILURE TO COMPLY COULD RESULT IN DEATH, BODILY INJURY, OR PROPERTY DAMAGE. For installation specifics, refer to Figure 11 and Figure 12 on page 6 and page 7 respectively for wiring diagrams, as well as pin-out Table 1 (power connections) and Table 2 (INCOM connections) on this page. Table 1. Power Connector Pin-Outs 1 Pin Number Input Signal 1 24 Vdc + 2 24 Vdc - 3 Control signal common 4 Control open signal 5 Control close signal 1 Module power uses a 5-pin input connector. Power requirement is 24 Vdc, 10 watts. Table 2. INCOM Connector Pin-Outs 1 Pin Number Signal 1 INCOM carrier network 2 INCOM carrier network 3 Shield 1 Connect shield wire to ground at master device end only. Interconnect shielding where devices are daisy-chained. Section 5: Jumpers and indicator LEDS Refer to Figure 10 to become familiar with specific jumper and LED locations on the INCOM communications adapter module. Jumper Plug for Source Sensing Status LED Jumper Plugs for Communication Control Figure 10. INCOM Communications Adapter Module (Front View Closeup) MicroController LED (Status) This indicator will be flashing green whenever the module is powered up and when the microprocessor is executing instructions. When the Series NRX INCOM communications adapter module is connected to a Digitrip unit for the first time, this LED will alternately flash red and green to signal a learning process between both units. This automatic process will take approximately 15 seconds and occurs only once during the initial startup. The LED will also flash red if the module is not connected to, or unable to communicate with a Digitrip unit. INCOM control jumper This jumper provides the user with a means of enabling or disabling remote communication control commands to the Series NRX trip unit. With jumper placed in the ENABLE position, remote slave action commands, such as open and close, can be acted upon. With the jumper in the DISABLE position, commands will not be accepted. Source/residual ground selection jumper This jumper selects the protection configuration for Series NRX trip units with ground fault protection or ground fault alarm functionality. Consult Series NRX trip unit instructions (IL01301051E) for further information on ground sensing. This jumper is not applicable and does not function for non-ground fault style trip units. EATON CORPORATION www.eaton.com 5

Effective July 2015 The Series NRX communications module is a separate device that snaps into the DIN rail starting at location 19-26. (Removal of the four contact blocks is required.) The trip unit auxiliary voltage is 24 Vdc ±10% and should be sourced from a reliable service, with 10 watt capability. INCOM communication cable is a two conductor with shield type wire in daisy chain configuration. The recommended cable (Belden # 9643 or equivalent) has a twisted-pair of wires (#20 AWG stranded 7 x 28 conductors with PVC insulation) having an aluminum/mylar foil shield with drain wire. The polarity of the twisted-pair is not important. Ground the shield at the host computer (device). Set the jumper on the module to enable or disable the remote open and close communication control commands, as desired. When the communications module is employed and source ground or zero sequence ground sensing method is required, the ground fault function is enabled by this jumper. Connectors are UL /CSA rated 300V, VDE rated 250V. Recommended: Weidmuller (BL 3.5/90/5BK) Orientation: 90 lead exit, but other lead orientations are possible. Wire gauge: #18 AWG/0.82 mm. The final device in the daisy-chain configuration must have a 100 ohms termination resistor installed across terminals #1 and #2 on TB #2. Figure 11. Series NRX INCOM Communication with Digitrip 520M 6 EATON CORPORATION www.eaton.com

Effective July 2015 Choose spring release coil voltage rating as desired if communications is required. Choose shunt trip voltage rating to be the same as spring release voltage rating if communication is required. Control power voltage rating must match ST and SR coil voltage rating. Close duration is two seconds on communication activation when communications control is enabled. Figure 12. Spring release and shunt trip wiring as shown for optional communication close or open capability Section 6: Viewing/setting INCOM address The Digitrip unit is used as the means to display and modify the programmed INCOM address setting of the ICAM module. All modules are shipped with a factory set default address of 4094. The allowable address range is 0001 4094. A trip unit containing a full display, such as the Digitrip 1150, will provide the ICAM settings in menu form. To set or view ICAM settings on a Digitrip 520M limited display, the following sequence is used. To set or view the address, depress and hold the Reset/ Battery Test button located on the front of the Digitrip unit for approximately 5 seconds until the address information is displayed. This button must be held in continuously during the process. The Digitrip unit display will then alternate between SP00 (denoting the address display mode) and the programmed INCOM address value. To select a new address, depress the trip unit Step button to increment the address value shown. Users may simultaneously depress and hold in the Step and Reset/Battery Test buttons for fast advance. The next setting will be displayed when the Reset/Battery Test button is released and then once again depressed. Once the last setting (SP01) has been viewed and the Reset/ Battery Test button has been released, the new INCOM address will be saved. A block diagram of the setting sequence and programming options is shown in Figure 13. For the Digitrip INCOM communications adapter module, two communication settings are available and can be viewed as shown in Table 3. SP00 SP01 Address Range 0001 4094 Baud Rate 01 Figure 13. Digitrip 520M Setting Sequence Programming Flow Chart EATON CORPORATION www.eaton.com 7

Effective July 2015 Table 3. ICAM Communication Setting Ranges Setting Number Allowable Range Communication address SP00 0001 4094 Baud rate SP01 01 1 1 For Series NRX INCOM communications adapter module, baud rate is fixed at 9600 baud and represented by a value of 01. Section 7: Network communication protocols The INCOM communication for the Series NRX INCOM communications adapter module is based on a master (PC, communicating trip unit, etc.) slave (NRX INCOM communications adapter module) set of protocols. For more comprehensive information on the NRX INCOM communications adapter module communication protocol, please see the following reference material: IL 17384 Part A: INCOM Communications Standard Section 8: Troubleshooting The most common issues experienced with the installation of a Series NRX INCOM communications adapter module are addressed below. If you have additional questions or need further information and/or instructions, please contact your local Eaton representative or visit www.eaton.com. Observation 1 Status LED not flashing Action Verify proper input power to module connectors. Observation 2 Status LED flashing green, but module does not change state in response to master command requests Action Verify correct module address. Action Verify communication cable is connected correctly from master to module. 8 EATON CORPORATION www.eaton.com

Effective July 2015 Disclaimer of warranties and limitation of liability The information, recommendations, descriptions, and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment, and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability, or otherwise for any special, indirect, incidental, or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations, and descriptions contained herein. The information contained in this manual is subject to change without notice. Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township, PA 15108 United States 877-ETN-CARE (877-386-2273) Eaton.com 2015 Eaton Corporation All Rights Reserved Printed in USA Publication No. IL01301033E July 2015