RT7. Practical commercial roofing & cladding solutions innovative products www.roof.co.nz

Similar documents
Roofing with Style. Roofing Cladding Rainwater Systems. Practical residential roofing & cladding solutions innovative products

When considering Roof drainage design the following should be taken into account:

December J-Ply Roofing, Flooring and Decking

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

There s a LYSAGHT walling solution to suit every Australian building. Walling Solutions 2PF300 PAGE 1

ROOFING SOLUTIONS PRODUCT GUIDE ROOFING SOLUTIONS PRODUCT GUIDE ROOFING JAN STR0229

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

ABSeam Panel Overview and Installation Instructions

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: Purpose

Preformed Metal Roofing and Siding

Residential Roofing Guide

SECTION STANDING SEAM METAL ROOF

INSTALLATION. General. Important Note. Design. Transport

Connection Solutions

ROOFING SOLUTIONS PRODUCT GUIDE ROOFING SOLUTIONS ROOFING, CLADDING AND RAINWATER SYSTEMS ROOFING SOLUTIONS PRODUCT GUIDE JAN 2014 STR0205

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

STEEL BUILDINGS RECOMMENDED INSTALLATION GUIDE

Section Page Section Page

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents


FS Deck Mounted Skylight Installation Instructions 15-90


Metal Roofing Practical Design

INSTALLERS GUIDE. November 2005 (Replaces September 2003)

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra Includes:

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

your home your style your way

GUIDELINE SPECIFICATIONS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Installation Manual for STANDING SEAM ROOFING

SECTION PREFORMED METAL STANDING SEAM ROOFING

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Including. Rubershield-Pro. Breather Membrane

Quality Regulations for Profiles

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

The WANZ Guide to Window Installation

KAHU RESIDENTIAL ROOFING RRKA DETAIL LIST

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Window Installation Instructions

Monarflex Vapour Control Layers

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Colonnade Security Pipe

TECHNICAL RECOMMENDATION

Basement Window Installation Guide Hopper and Sliding

Cupa Natural Slate Roofing design and fixing guide

Asphalt Shingle Application Requirements

Screw Patterns Roof & Walls TR-36 MD-36 TSM-32. PBR-Panel

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

REVSPEC. Revolution Roofing Specifier s Manual

PART 1 GENERAL 1.1 SECTION INCLUDES

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES

White rust on galvanized and galvanized pre-painted steel. Technical Information

Protecting Your Home From Hurricane Wind Damage

8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

FLASHCLAD VERTICAL WEATHERBOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 829 [2013] Appraisal No. 829 (2013) Amended 05 February 2016

Guide to Safe Building Practices

Detached accessory structures that contain no conditioned floor area are exempt.

AA Solar and Sun Power Plus

VM ZINC : standing seam Guidelines for specification and installation

Standing Seam Roof Systems

Installation Detailed installation instructions are provided which should be strictly followed.

PRO-PANEL II. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

Mark Cramer Inspection Services, Inc.

700mm Effective cover width 710mm Overall width

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

SANS FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/ / / /341

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

SECTION 4: Cable Ladder Stainless Steel & Aluminium

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

Shingle Installation Guide

Greenhouse Assembly Instructions

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

CHAPTER 7: Building Systems ROOFING SYSTEMS

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

Rain Penetration Tests on Manthorpe Mini Castellated Vent Tile with 15" x 9" Format Roof Tiles. Prepared for: Ben Hales

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

Timber Decks. Technical Note. March 2007

Prelease Schedule of Condition and Want of Repairs at Milton Keynes for May

Rooflight INSTALLATION INSTRUCTIONS

SECTION ROOFING TILE

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

Nucor VR16 II TM Vertical Rib Standing Seam Roof System

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

SECTION STANDING SEAM METAL ROOFING

Transcription:

RT7 Practical commercial roofing & cladding solutions innovative products www.roof.co.nz february 2010

RT7 escription RT7 is a visually appealing medium rib-height trapezoidal roofing profile, has an exceptional strength to weight ratio and demonstrates impressive spanning capability and water carrying capacity at a relatively low pitch. Manufactured from high tensile material and supplied in a range of substrates and surface finishes, RT7 lends itself to a wide range of design options, including curving, and is equally practical when utilised as commercial, industrial or residential roofing and cladding. Features A purpose designed stiffened underlapping support leg offers: Extra support for the over-lapping edge Prevents separation of the lapping edge Prevents water ingress at the laps Prevents deformation when screwing off the roof Roofing installer friendly and saves on installation costs As the laps remain closed RT7 provides uniform lines an be drape curved apillary groove to lapping edge Available reverse-run old and visually appealing Applications ommercial and industrial roofing Residential roofing ladding in standard or reverse run profile rape curving Fencing Garage door cladding uilding esign / Performance riteria / Product selection uring the design of buildings, it is necessary for the designer to take into account a number of factors to ensure that the most appropriate roofing and cladding product is chosen. Whilst aesthetics and product availability do play a part, the chosen profile must meet certain performance criteria. These are centered around the profile s ability to shed water from the roof and the ability of the product to span purlin and girt spacings and meet design criteria. The minimum pitch for this profile is outlined elsewhere within this literature. In terms of purlin spans and girt spacing it is necessary to follow due process. If a building is being designed in accordance with E2/AS1 and roofing and cladding products as covered by that document are chosen, then it is necessary for the design spans to comply with those of E2/AS1. However where a building is outside of the scope of E2/AS1 and the building or parts thereof are of specific design then it is necessary for the roofing and cladding to be suitable for the design and vice versa. Underlap Support Leg Single apillary reak RT7 20 76 8 51 127 38 43 889 (Effective over) 965 125º All measurements are in millimetres our published technical information. Roofing Industries Technical Helpline 0800 844 822 www.roof.co.nz

Wind Load Span esign Graph RT7 G550 Steel Wall ladding Application Primary Fixing Method: Fixed in the pan with approved 12 gauge screws and neos. Pattern, (hit-miss-hit-miss-hit-miss-hit). End fixings to be every pan. Loadings referred to in Roofing Industries graphs are the result of testing to a serviceability limit state which is more conservative than an ultimate limit state as quoted by some manufacturers. Our esign Graphs are presented in a form to allow the designer to select suitable products and maximum purlin spacings. It is first necessary for the designer to calculate the design wind load for the roofing and cladding in accordance with generally acceptable practice, by reference to AS/NZS 1170: 2002, and/or NZS 3604: 1999 as appropriate. For a fuller explanation of this refer to the NZ Metal Roof and Wall ladding ode of Practice. For most roof installations the purlin spacings will be limited by the trafficable limitations of the profile. However for roofs that are not able to be walked on and for wall cladding applications, these limitations may be exceeded providing the design wind loading criteria is met. However this should be done with caution as it may require considerable extra secondary fasteners within the laps. The designer should always take into account in areas of heavy roof traffic, or where the roofing supports such items as air conditioning units, and in these instances purlin spacing should be reduced accordingly. Reference should be made to the notes in the graphs. It is our recommendation that for commercial and industrial roofing applications that.55 mm MT is used as it has more resilience to damage, particularly by other trades. kpa 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 Ref # RT7W2 0.55 mm MT Steel 0.40 mm MT Steel 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Metres Intermediate span in metres. End spans to be a maximum of 2/3 of this span. Type 3 lassification. Other fixing patterns may be used but these will alter the design load. Refer to www.roof.co.nz for further details and other substrates. Tested in accordance with the NZMRM test procedure. Note: Wind Load Span Graph is based on information derived from extensive testing of RT7 on the Test rig, utilising variations in fasteners, fixings and patterns covering both roofing and cladding applications. lassification Type is from the NZ Metal Roof and Wall ladding ode of Practice. our published technical information Roofing Industries Technical Helpline 0800 844 822 www.roof.co.nz

Wind & oncentrated Load Span esign Graph RT7 G550 Steel.40 mm MT Roofing Application Primary Fixing Methods: A Fixed every purlin, every rib with approved screws and neos, load spreading profiled metal washers and EPM washers. load spreading profiled metal washers and EPM washers. End purlins to be fixed every rib. and alloy embossed washers. End purlins to be fixed every rib. kpa 8.0 7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 A 0.40 mm MT Steel Trafficable 1 Wind load only 2 0.5 0 Ref # RT7R2 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Metres Intermediate span in metres. End spans to be a maximum of 2/3 of this span. 1 The solid line represents where walking is permitted within 300 mm of the purlin line or spreading the live load over 2 ribs. Therefore for a normal roof, and providing wind load requirements are met, purlin spans are limited to: without washers. End purlins to be fixed every rib. Maximum Spans Intermediate End Type 2 Restricted Access lassification 0.40 mm MT 1.9 metres 1.3 metres 2 The broken line represents untrafficable roof areas and is wind loading only and has a Type 3 lassification. In areas of heavy roof traffic, or where the roofing supports such items as air conditioning units, purlin spacing should be reduced accordingly. For Type A Unrestricted Access lassification, refer to Roofing Industries. Other fixing patterns may be used, however these will alter the design load for wind only. Refer to www.roof.co.nz for further details and other substrates. Tested in accordance with the NZMRM test procedure. Note: Wind & oncentrated Load Span esign Graph is based on information derived from extensive testing of RT7 on the Test rig, utilising variations in fasteners, fixings and patterns covering both roofing and cladding applications. lassification Type is from the NZ Metal Roof and Wall ladding ode of Practice. our published technical information Roofing Industries Technical Helpline 0800 844 822 www.roof.co.nz

Wind & oncentrated Load Span esign Graph RT7 G550 Steel.55 mm MT Roofing Application Primary Fixing Methods: A Fixed every purlin, every rib with approved screws and neos, load spreading profiled metal washers and EPM washers. load spreading profiled metal washers and EPM washers. End purlins to be fixed every rib. and alloy embossed washers. End purlins to be fixed every rib. kpa 8.0 7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 A Ref # RT7R1 0.55 mm MT Steel Trafficable 1 Wind load only 2 0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Metres Intermediate span in metres. End spans to be a maximum of 2/3 of this span. 1 The solid line represents where walking is permitted within 300 mm of the purlin line or spreading the live load over 2 ribs. Therefore for a normal roof, and providing wind load requirements are met, purlin spans are limited to: without washers. End purlins to be fixed every rib. Maximum Spans Intermediate End Type 2 Restricted Access lassification 0.55 mm MT 3.6 metres 2.4 metres 2 The broken line represents untrafficable roof areas and is wind loading only and has a Type 3 lassification. In areas of heavy roof traffic, or where the roofing supports such items as air conditioning units, purlin spacing should be reduced accordingly. For Type A Unrestricted Access lassification, refer to Roofing Industries. Other fixing patterns may be used, however these will alter the design load for wind only. Refer to www.roof.co.nz for further details and other substrates. Tested in accordance with the NZMRM test procedure. Note: Wind & oncentrated Load Span esign Graph is based on information derived from extensive testing of RT7 on the Test rig, utilising variations in fasteners, fixings and patterns covering both roofing and cladding applications. lassification Type is from the NZ Metal Roof and Wall ladding ode of Practice. our published technical information Roofing Industries Technical Helpline 0800 844 822 www.roof.co.nz

RT7 Roof Pitch The minimum pitch for RT7 is 3 for combined lengths up to 40 mtrs. For runs in excess of this contact Roofing Industries. esign pitches may need to allow for deflection of the structure Materials Zincalume Steel:.40 mm MT or.55 mm MT, AZ150 (150gm/m 2 ) G550 Mpa Yield Stress Galvanised Steel:.40 mm MT or.55 mm MT, Z450 (450gm/ m 2 ) G550 Mpa Yield Stress Pre-painted or over Zincalume.40 mm MT or.55 mm MT, AZ150 (150gm/m 2 ), G550 Mpa Yield Stress Prepainted or over Galvanised Steel:.40 mm MT or.55 mm MT ZM275 (275gm/m 2 ) G550 Mpa Yield Stress For information on Aluminium, Stainless Steel and opper RT7, contact Roofing Industries. urability Selection of the correct grade of material and appropriate surface coating is imperative to ensure RT7 will perform satisfactorily in the environment it is to be installed, and meets the requirements of The NZ uilding ode. Environmental ategories and Surface oating literature is available from our website www.roof.co.nz. Accessories A full range of matching accessories is available, including Ridging, Flashings, Underlays, Insulation, Fasteners, Rotary Roof Ventilators and Rainwater Systems. Underlay Underlay as per the project specification is to be used. Translucent roofing RT7 is available as glass reinforced translucent roof and wall lighting. Fixings and Fasteners All fixings and fasteners are to be of an approved type, compatible with all materials, the environment and meeting the requirements of the NZ uilding ode. Installation is to be in accordance with the NZ Metal Roof and Wall ladding ode of Practice or manufacturer s instructions. Roof application Using the appropriate fixing method from the Wind & oncentrated Load Span esign Graphs. From the ridge down for dark coloured roof sheets up to and including 8 metres, and for light coloured and Zincalume roof sheets up to and including 12 metres, solid fix. For sheet lengths in excess of the above, oversize holes should be used for the remainder of the sheet and approved load spreading profiled or alloy embossed washers used for the entire sheet. Fix every crest to: Ridge, Hip, Valley, Gutter and Periphery areas. Standard Primary Fixings are: For Timber Purlins use 14 x 75 Timbertite lass 4 Screws with neos and with (or in some cases without) appropriate washers as above. For Steel Purlins use 12 x 65 Steeltite lass 4 Screws with neos and with (or in some cases without) appropriate washers as above. Walling application Using the appropriate fixing pattern from the Wind Load Span esign Graph, fix in the pan adjacent to the ribs using 12 gauge lass 4 Steeltites or Timbertites and neos as appropriate, ensuring that when the fastener is into timber it is of sufficient length to penetrate the framing by 30 mm. The pan fixing at the lap is to be adjacent to the rib. Note: These recommendations are suitable for steel based materials, for other materials refer to our website www.roof.co.nz. Other fixing methods may be applicable in some circumstances. urving Minimum pitch of drape-curved roofing is primarily governed by the overall appearance of the sheeting after installation. A tight radius may lead to distortion, and Roofing Industries should be consulted for Purlin spacing and minimum radius during the design phase. Ordering Roofing Industries staff can provide technical assistance to ensure accurate ordering of roofing and accessories thereby avoiding costly errors. RT7 is delivered cut to length subject to transport restrictions. Handling and storage On delivery, visually inspect sheets for damage. Store RT7 and accessories on evenly spaced and supportive dunnage, clear of the ground and under cover. If packs become wet and the product not used immediately, separate the sheets to allow air circulation and drying. o not drag sheets across each other. Long lengths of roofing should be lifted onto the roof using an approved load spreading beam. If protected with strippable plastic film, keep under cover and remove as the product is being installed. Installation Prior to commencing the project, refer to Roofing Industries technical literature and website www.roof.co.nz. Failure to install RT7 and accessories to industry requirements will void any warranty. Guide to minimum radius (m) ase Material.55 mm MT 0.90 mm 2400g/m 2 (1.5 mm) Zincalume 50 Galvanised 50 H36 5052 Aluminium 50 Translucent GRP 14 Natural Lighting NOTE:.40 mm MT Steel substrate and 0.70 mm Aluminium substrate are not recommended for drape curving. Maintenance Maintenance Guides are available and should be consulted in order that warranty conditions are fulfilled. Warranties Warranties meet the statutory requirements of the NZ uilding ode, are available on request and reflect our New Zealand owned and operated company, test facilities and local climatic conditions. Available at www.roof.co.nz. Auckland (Head office) Roofing Industries Ltd 5 John Glenn Avenue, North Harbour PO ox 302-385 North Harbour 0751 Ph: (09) 414 4585 Fax: (09) 414 4586 office@roof.co.nz Whangarei Roofing Industries (Northland) Ltd 38 Winger rescent, Kamo, Whangarei PO ox 883 Whangarei 0112 Ph: (09) 437 2040 Fax: (09) 437 5010 northland@roof.co.nz Waikato Roofing Industries (Waikato) Ltd Unit 4/550 Te Rapa Rd Te Rapa, Hamilton PO ox 20281 Te Rapa, Hamilton 3241 Ph: (07) 849 5115 Fax: (07) 849 2115 waikato@roof.co.nz Taupo Roofing Industries (Taupo) Ltd 1158 Rakaunui Rd Taupo PO ox 408 Taupo 3351 Ph: (07) 376 7971 Fax: (07) 376 7972 taupo@roof.co.nz Palmerston North Roofing Industries (entral) Ltd 653 Tremaine Ave Palmerston North PO ox 4584 Palmerston North 4410 Ph: (06) 353 8480 Fax: (06) 353 8470 central@roof.co.nz South Island Roofing Industries Ltd 220a Annex Road P O ox 6248 Upper Riccarton hristchurch 8442 Ph: 03 339 2324 Fax: 03 339 2325 south@roof.co.nz Your distributor Need a roof visit www.roof.co.nz