ISHIDA BC-3000. Scale to Scale Communications

Similar documents
Cable Specifications and Information

Encore Controller to Router Connections

T3 Mux M13 Multiplexer

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Using HyperTerminal with Agilent General Purpose Instruments

Cable Pinouts. SRP I/O Module

One Port Serial Server Users Manual Model ESP901, ESP901E

MODBUS TCP to RTU/ASCII Gateway. User s Manual

Modbus Communications for PanelView Terminals

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

Connector and Cable Specifications

Fanuc 0 M/T Model C Serial (RS232) Connection Guide

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

CDI-S100 SERIAL INTERFACE CARD

LTM-1338B. Plus Communications Manual

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

32 Transferring Projects and Data

Connector and Cable Specifications

How To Send A Message From A Computer To A Computer (Iwea) On A Microsoft Macbook 2.5 (Isoa) To A Microsatellite 2.4 (Ios) On An Unix (Ise

Appendix A. This Appendix includes the following supplemental material:

MINIMUM TOOL REQUIREMENT FOR EPROM UPGRADE

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

IP SERIAL DEVICE SERVER

User Manual IC-485AI

Auxiliary equipment for communication with the EuroProt protective devices

BACnet Automation Interface Module (Network Version)

Setting Up the ZigBee Ethernet Gateway

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

RS-232/422/485, Power over Ethernet

Cable Specifications and Information

LBNP RS-232/485/422 serial device server. User manual

Cabling Guide for Console and AUX Ports


ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

SecureLinx Spider Duo Quick Start Guide

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

ENGINEERING DOCUMENT. Subject: Hardware Installation Procedure for Ultinet Networking Option.

All other brands and their products are trademarks or registered trademarks of their respective holders, and should be noted as such.

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Single channel data transceiver module WIZ2-434

PN L, Revision B, October Epic 950 TM. Master Programmer User s Guide

PCMCIA 1 Port RS EDITION OCTOBER 1999

AT-S99 and AT-S102 Version Management Software for the Converteon Media Converter Products. Software Release Notes

Comtrol Cable User Guide

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

The Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

Connectors and Cables

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

Date Rev. Details Author

Professional USB to Serial Adapter Hub with COM Retention

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

Hardware Installation and Configuration Guide

MS830 / MS833 Barcode Reader v1.0 9-December-2014

History of Revisions. Ordering Information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

1 Serial RS232 to Ethernet Adapter Installation Guide

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

Application Note: Extending a TSP s Analog Capabilities Using an Access Bank I

RS-232 COMMUNICATIONS

Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

HOMEWORKS. RS-232 Protocol. Data Protocol for Communicating with Lutron's HOMEWORKS System

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

1 Port RS232 Serial over IP Device Server

Manual Serial PCI Cards

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

Communication standards and Carel solutions

Vicon Flash Upgrade Software

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

UltraCade Multi-Game System Frequently Asked Questions

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

2100 POS System User Guide

Acano solution. Acano Solution Installation Guide. Acano. January B

SUPERSTACK II HUB TR NETWORK MANAGEMENT MODULE INSTALLATION GUIDE

XPort Universal Demo Board User Guide

Connecting and Setting Up Your Laptop Computer

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

File Management Utility. T u t o r i a l

Stevens Cell-Net CDMA & GSM M2M 3G Data Modem. Product Manual

IntesisBox Modbus Server SAMSUNG Air Conditioners

Wash Select II to WashPay Integration Field Retrofit Installation Guide

Voice Over Internet Protocol (VoIP) Configuration

PPM Users Manual Signature Software

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

Bluetooth to Serial Adapter

IP Serial Server. User Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

NPort DE-311 Hardware Installation Guide

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

Transcription:

ISHIDA BC-3000 Scale to Scale Communications Setup Procedure & Operating Instructions March 2006 PN 94561

Revision History Date Page Description March 2006 Initial publication August 2006 2 Added RS-232 cable information

Overview...2 Communication Cables...2 Scale to Scale...2 Scale to PC (RS-232)...2 Scale to Scale Communications with a Master Board...3 System Configuration...3 Additional Components...3 Firmware...3 Installing the Master Board (P-835) into a BC-3000 Master Scale...4 Master Board Kit Components (Part No 48744 or 48745)...4 Procedure...4 Configuration Programming...6 Test Mode...6 Programming Mode...8 Communication Settings...9 Label Formats...9 Chinese (Hong Kong) firmware (version C1312x) - Special RAM Clear...10 Background...10 Procedure...10 Notes...10 Scale to Scale Communications without a Master Board...11 Overview...11 Configuration...11 Communication Cable...12 Programming...12 Operation...12 Totals...12 Errors...12 Label Formats...12 Miscellaneous...12 Rev 2, August 2006 1 BC-3000_ScaletoScale_Comms

Overview There are two methods available to interconnect the Ishida BC-3000 printing scales with important differences between the two. This document provides details to setup each of these two BC-3000 scale to scale networks. The original method allows up to five BC-3000 scales to be connected. These scales only communicate during PLU programming and price changes. Note that Scale #1 does not support PC communications as part of the system. PLU and price changes must be programmed at Scale #1. In this document this system is referred to as a "No Master Board" system. The new BC-3000 scale network utilizes a Master board which provides on-line communication between the Master and Satellite scales. Up to 30 Satellite scales can be connected to the Master scale. The Master board allows communication to the Satellite scales as well as a PC. This system is referred to as "With Master Board". Refer to Table 1 below for a summary of each system. Feature With Master Board No Master Board Maximum number of scales 31 5 PC Communications Yes No Communication Method On-Line Download during programming Ethernet communications Optional, Master scale only Not available Table 1. Comparison of BC-3000 Scale Systems Communication Cables Scale to Scale A shielded 4-conductor twisted-pair cable is used to inter-connect the scales for both BC-3000 system types. The cable is terminated at a 9-Pin Sub-Miniature D-Type male connector. Grounding, if available, is made at only one point - the chassis of the Master scale (Scale #1). At the other scales the ground wires are "daisy chained" between the cables without connection to the scales. The ground cable at the last scale is not used. Cable Pinout (straight through configuration) Pair One Pair Two 5 ----- 5 Data 9 ----- 9 Data 3 ----- 3 Signal Ground 7 ----- 7 Frame Ground Scale to PC (RS-232) A communication grade cable is required to connect a BC-3000 Master Scale to a PC. The pinout of the required standard, straight-through RS-232 cable is shown below. PC (9 pin) [female] Scale (25 pin) [male] 1 8 (DCD) 2 3 (Rx) 3 2 (Tx) 4 20 (DTR) 5 7 (Signal Ground) 6 6 (DSR) 7 4 (RTS) 8 5 (CTS) 9 22 (RI) Note: The mounting terminals for the I2NET and RS-232 connections are metric. The screws supplied with standard US DB9 and DB25 connectors should be replaced with the following metric screws: 2.5mm x 12mm screws. Rev 2, August 2006 2 BC-3000_ScaletoScale_Comms

Scale to Scale Communications with a Master Board Figure 1. BC-3000 Master - Satellite System System Configuration The BC-3000 on-line scale system allows connection of up to thirty-one (31) BC-3000 scales in one system. For this system a P-835 Master board must be installed in the Master scale. Please refer to section "Installing the Master Board (P-835) into a BC-3000 Master Scale" for instructions. All units are connected by I2NET cables. Please refer to section "Communication Cable" for I2NET cable specifications. Note that only BC-3000 scales may be interconnected. The BC-3000 cannot be connected as a Satellite scale to an AC-3000 Master scale. Additional Components The Master scale in the "With Master Board" system requires the following hardware to fully support Master scale communications. Two additional harnesses: Part 88984 -- I2NET harness Connects: Two external I2NET DB9, Master board J3, and CPU board "I2NET" Part 88992 -- DC/DC Power harness Connects: CPU board CN12, Master Board J2, and Display junction board CN1 One of the following Master Board kits: Part 48744 -- Master Board Kit, 256K Memory Part 48745 -- Master Board Kit, 1M Memory An Ethernet Communication option is available for the Master scale in the "With Master Board" system. Part 65104 -- Ethernet option, 10baseT communication Firmware Two versions of BC-3000 firmware support Master - Satellite on-line communications. One is the standard English dual-range weighing and the other is Chinese (Big-5) single-range weighing. All hardware is the same between the two systems. Only the firmware EPROMs installed in the scales is different. Note that the same EPROM version must be installed in each scale in a system. The following table lists the firmware versions for each system. English Chinese (Big-5) Main EPROM C1372x C1312x Font EPROM F0194 F0254 Master EPROM B0331x C1099x* * Note: DIP Switch 8 on Master Board must be set = ON Table 2. English vs. Chinese Firmware Rev 2, August 2006 3 BC-3000_ScaletoScale_Comms

Installing the Master Board (P-835) into a BC-3000 Master Scale Master Board Kit Components (Part No 48744 or 48745) The kit includes the following parts. Master board (P-835)...1 Guide rails...2 Collar...1 M3 screw...1 Harness...1 (use part 88984 - "I2NET harness") RS-232C Harness...1 Bracket...1 Hex mounting bolts...2 Figure 2. Installation of P-835 Master Board Procedure 1. If necessary, replace the connector bracket on the left side of the BC-3000 to accommodate the 25-pin RS-232 harness. Or remove the existing 25-pin RS-232 harness that is connected to the CPU board. 2. Mount the RS-232C harness from the kit into the connector bracket on the left side of the BC- 3000 using the two Hex mounting bolts. 3. Replace the I2NET harness with the new I2NET harness (Part 88984). 4. Connect the new I2NET harness to the CPU board connector marked "I2NET". 5. Replace the DC/DC Power harness with the new harness (Part 88992). 6. Mount the two rails as shown in Figure 2. 7. Install the appropriate EPROM in the Master Board. Refer to Table 2. 8. Move the Master board battery switch to the ON position. 9. For Chinese (Big-5) firmware (C1312x) set DIP Switch 8 to ON. 10. Connect the RS-232 harness to the Master board at J1. 11. Slide the Master board into the two rails. 12. Connect the new I2NET harness to the Master board at J3. 13. Connect the new DC/DC Power harness to the Master board at J2. 14. Place the plastic collar under the front, right corner of the Master board. 15. Secure the Master board using the M3 screw. Rev 2, August 2006 4 BC-3000_ScaletoScale_Comms

Display junction board CN1 Master Board J2 CPU board CN12 Figure 3. Part 88992 -- DC/DC Power harness External I2NET CPU board "I2NET" Master Board J3 Figure 4. Part 88984 -- I2NET harness Rev 2, August 2006 5 BC-3000_ScaletoScale_Comms

Configuration Programming After the hardware has been added to the Master scale and the correct EPROMs installed, the scales must be configured to communicate. Each scale is set as either a Master or a Satellite. Then each scale is uniquely numbered and set "on-line". These configuration steps are listed below. When the BC-3000 is upgraded to support Master - Satellite communications the memory must be cleared due to the changes to the memory structure. If the BC-3000 has data files that will be reused, make a back up of the files with the IF-21 Floppy Disk Recorder prior to clearing the scale's memory. Refer to the BC-3000 Service manual section S5.2 "Data Send/Load (C99)" for complete details. To navigate the BC-3000 menus use the arrow keys ( ) and the ENTER key. To exit use the END and MODE keys. Test Mode Enter the Test Mode to clear memory, assign the scales as either a Master or a Satellite, and transfer data files by the IF-21 Floppy Disk Recorder. To access Test Mode turn on the power switch while holding down the 1 key. The display shows C00 indicating the Test Mode. Clear Memory (C2-01) This item is used clear all RAM data on the main CPU board. Press ZERO twice. When all RAM data has been cleared, [OK] will be displayed. Clear Configuration (C2-01) This item is used clear all configuration data on the main CPU board. Press ZERO twice. When all configuration data has been cleared, [OK] will be displayed. Test Set (C2-03) This item is used to write test data to the main CPU board memory. Press ZERO twice. When Test Data has been created, [OK] will be displayed. Note: this procedure is optional. Scale Mode (C08-02) This item is used to define whether the scale is used as a stand alone unit or is linked to a system as a Master or Satellite scale. Enter the number corresponding to the desired mode, then press ENTER. Note: If the Master board memory is unformatted, the BC-3000 will move immediately to step C102-01 "Memory Clear" after selecting Scale Mode as Master Scale. Scale Mode Value Stand Alone 1 Master Scale 2 Satellite Scale 3 Table 3. BC-3000 Mode Settings Program No. (C101-05) This item is used to display the firmware version number of the Master board. Clear Memory (C102-01) This item is used clear all RAM data on the Master board. Press ZERO twice. When all RAM data has been cleared, [OK] will be displayed. Rev 2, August 2006 6 BC-3000_ScaletoScale_Comms

Test Set (C102-02) This item is used to write test data to the Master board memory. Press ZERO twice. When Test Data has been created, [OK] will be displayed. Memory Check (C105-00) This item is used to check the amount of memory (in kilobytes) on the Master board. The first value is the Total Memory. The second value is the Remaining Memory. Data Send/Load (C199) This item is used for data communication with an IF-21 Floppy Disk Recorder. All IF-21FD operations can be performed from the BC-3000 keyboard. Before attempting to transmit data, make sure the BC-3000 is connected to the IF-21 unit, and the scale and IF-21 power switches are ON. Refer to Table 4 for a list of the files that can be transmitted by the IF-21. File Number File Name File Number File Name 1 All Files 12 ---- 2 Master File # 13 ---- 3 E2ROM File + 14 Title File 4 PLU File* 15 Department File* 5 Store Name File* 16 Group File* 6 ---- 17 ---- 7 Extra Message File* 18 ---- 8 Operator File* 19 ---- 9 Preset Keys File 20 SubTotal File 10 Label Format File 21 Nutrition File* 11 Configuration File # Transmits files 4-9, 12-21 + Transmits files 10 and 11 * Compatible with AC-3000 Table 4. IF-21 Floppy Disk Files. File Transfer (C199-02) File Transfer is used to transmit, verify, and delete (from the floppy disk) data files. IMPORTANT: The floppy disk must have been formatted using step C99-03 prior to performing file transfers as described in steps C199-02-0x. Select IF-21 Track No. (C199-02-01) Enter the number corresponding to the desired floppy disk track number (1-8), then press ENTER. Send (C199-02-02) This item is used to transmit data from the scale to an IF-21 Floppy Disk Recorder. Enter the number corresponding to the file(s) to be sent, then press ENTER. To start transmission press PRINT. Receive (C199-02-03) This item is used to receive data from an IF-21 Floppy Disk Recorder. Enter the number corresponding to the file(s) to be received, then press ENTER. To start reception press PRINT. Verify (C199-02-04) This item is used to compare data files between the IF-21 Floppy Disk Recorder and BC-3000. Enter the number corresponding to the file(s) to be compared, then press ENTER. To execute press PRINT. Rev 2, August 2006 7 BC-3000_ScaletoScale_Comms

Delete (C199-02-05) This item is used to delete all files. Press ZERO twice. All files will be deleted. BC-3000 Scale to Scale Communications Programming Mode Enter the Programming Mode assign the scale number and set the scale on-line or off-line. To access Programming Mode enter the password 9000 and press the MODE key. The display shows P00 indicating the Programming Mode. Note that 9000 is the default password but it can be changed. Scale Number (P17-01) This item is used to assign a unique number to each scale. The Master scale must be assigned #1. The remaining scales are assigned numbers 2 ~ 31. Note that the scale number will be display during power up and after exiting any menu. On-Line Mode (P19-01) This item is used to set the scales either on-line or off-line. Set the value as "1" (on-line) or "0" (off-line). Note that the BC-3000 will display the current On-Line setting during power up and after exiting any menu. Download (P20) This item is used to manually download data files from the Master board memory to the Satellite scale memory. The Download procedure is performed at the Satellite scale. Note that the Download can also be done at the Master scale to copy data files from the Master board to the Master scale's main CPU board memory. Refer to Table 5 to select the desired file and press the COPY key to execute. The items are counted on the display and "PASS" is displayed after the download is complete. File Number File Type P20-01 PLU File P20-02 Store Name/Address File P20-04 Extra Message File P20-05 Department File P20-06 Group File P20-07 Operator File P20-08 Preset Keys File P20-10 Title File* P20-14 Receipt Barcode File* *Not supported by BC-3000 Table 5. List of Files to be Downloaded from the Master. Rev 2, August 2006 8 BC-3000_ScaletoScale_Comms

Communication Settings Refer to Table 6 for the various communication settings used by the BC-3000. Setting Standard USA [C1372x] Chinese (Big-5) [C1312x] Master Board DIP Switch 8 = Off DIP Switch 8 = On Baud Rate ROM Switch 26 = 00 (9600, default) 1F = 00 (9600, default) = 01 (2400) = 02 (4800) = 03 (9600) = 04 (19200) = 05 (38400) ScaleLink Pro, RS-232 Baud Rate = see ROM Sw 26 Date Bits = 7 Parity = Even Stop Bits = 1 Baud Rate = 9600 Date Bits = 8 Parity = None Stop Bits = 1 ScaleLink Pro, Ethernet Do not check select "Assume 8- bit comms...". Select "Assume 8-bit comms...". If not, scale will connect but fail when data are transmitted. UDS-10 (Ethernet Converter) I/F mode = "78" I/F mode = "4C" Table 6. BC-3000 Communication Settings. Label Formats The default label formats for the standard US firmware and the Chinese (BIG-5) firmware are different. Refer to Table 7 below for the list of default label formats. Firmware C1372x / F-0194x USA Standard, Dual-Range Weighing C1312x / F0254x Chinese (BIG-5) Description Format #1: 60mm x 44mm Format #2: 64mm x 47mm Format #3: 64mm x 85mm, Safe Handling Format #4: 64mm x 59mm, Safe Handling Format #1: 60mm x 44mm Format #2: 64mm x 67.5mm Format #3: 64mm x 79mm, Nutrition + non-standard Barcode Format #4: 64mm x 85mm Coupon Table 7. Label Formats for BC-3000 scales. Rev 2, August 2006 9 BC-3000_ScaletoScale_Comms

Chinese (Hong Kong) firmware (version C1312x) - Special RAM Clear Background When special Chinese (Hong Kong) firmware (version C1312A) is installed in the BC-3000 it may not be possible to perform the standard memory clear procedure. This is because the firmware memory structure is significantly different from the standard USA firmware. This procedure covers the "special" memory clear procedure. Procedure 1. Remove the keyboard assembly and turn off the battery switch located on the main CPU board. 2. Wait 15 minutes for the circuit to fully discharge. 3. Turn on the battery switch and reassemble the keyboard assembly. 4. Hold down the HELP key (top, right corner) and turn on the power. "TEST" is displayed. 5. Key in 4141 and press the ENTER key. "C02-01" is displayed. 6. Press the DOWN ARROW key. "C02-02" is displayed. 7. Press the ZERO key twice. "PASS" is displayed. 8. Press the END key and turn off the power. 9. Enter the normal Test Mode: Hold down the 1 key and turn on the power. "C00" is displayed. 10. Perform the standard memory clear: a. Press the 2 key followed by the ENTER key. "C02-01" is displayed. b. Press the ZERO key twice. [RAM Clear] "PASS" is displayed. c. Press the DOWN ARROW key. "C02-02" is displayed. d. Press the ZERO key twice. [E2ROM Clear] "PASS" is displayed. 11. Press the END key and turn off the power. Notes This special procedure involving the HELP key and "4141" password is not available in the standard USA BC-3000 firmware. This procedure should also be followed if the BC-3000 memory becomes corrupted to the point that the standard memory clear does not work. Rev 2, August 2006 10 BC-3000_ScaletoScale_Comms

Scale to Scale Communications without a Master Board The BC-3000 firmware listed in Table 8 supports connecting up to five scales. When PLU related data such as Price Changes, Extra Messages, and Nutrition are programmed at Scale #1 the changes are automatically transmitted down to the other scales. Please refer to the Overview section below for a complete list of features and limitations of this "No Master Board" system. Firmware B-0312x / F-0194x B-0209x / F-0194x C-0840x / F0208x C-0877x / F-0218x Description Standard, Dual-Range Weighing Standard, Single-Range Weighing Korean/English, Single-Range Weighing Chinese/Japanese/English, Single-Range Weighing Table 8. BC-3000 Firmware. Overview A BC-3000 system without a Master board has limited communication capabilities as compared to a system with a Master board. Important system considerations are listed here. PLU and Price Changes programmed at Scale #1 are instantly sent to the other scales that is connected and set "on-line". After programming, Scale #1 and all of the remaining scales contain identical PLU files in their memory. If scales #2 through #5 are not connected or are turned off or are set "off-line" the changes cannot be registered into their memory. The memory from Scale #1 cannot be downloaded or retransmitted to the memory of any other scale. A maximum of five scales (Scale #1 plus four other scales) may be connected. PC communications is not supported by a "No Master Board" system. Scale #1 cannot communicate with a PC and simultaneously download the data to the remaining Satellite scales. Configuration Three separate memory areas of each BC-3000 scale must be configured to allow communications. A. Test Menu Step 06-01: ROM Switch [Access by powering up holding 1 key, 6, ENTER] Set the on-line flag in all scales: Address 2D = 1 [Access by entering the address and pressing the key] Identify Satellite scales (in Scale #1 only) Address 2E = 2 Address 2F = 3 (only if a third scale is connected) Address 30 = 4 (only if a fourth scale is connected) Address 31 = 5 (only if a fifth scale is connected) B. Programming Menu Step P17-01: Scale Number. [Access by password 9000, MODE, 17, ENTER] Scale #1 = 1 Remaining Scale2 = 2 ~ 5 Step P19-01: On-Line Mode. [Access by password 9000, MODE, 19, ENTER] On-Line = 1 Off-Line = 0 Rev 2, August 2006 11 BC-3000_ScaletoScale_Comms

Communication Cable Refer to the Communication Cable information on Page 2 of this document for details and specifications of the scale to scale communication cable. Programming The following programming steps are available at Scale #1 only: 1 - PLU Editing 2 - PLU Name 22 - Price Changes Operation A BC-3000 system scale operates the same as a normal stand-alone machine. Totals A BC-3000 system scale operates the same as a normal stand-alone machine. Totals must be taken at each machine separately. Errors If a Satellite scale is not communicating scale #1 will display: On Line Error No X where X is the Satellite number that is not communicating. Label Formats The default label formats differ depending on the weighing method: Single-Range vs. Dual-Range. Refer to Table 9 below for the list of default label formats. Firmware Description B-0312x / F-0194x Format #1: 60mm x 44mm Standard, Dual-Range Weighing Format #2: 64mm x 47mm Format #3: 64mm x 85mm, Safe Handling Format #4: 64mm x 59mm, Safe Handling B-0209x / F-0194x Format #1: 60mm x 44mm Standard, Single-Range Weighing Format #2: 64mm x 47mm C-0840x / F0208x Format #3: 64mm x 85mm, Safe Handling Korean/English, Single-Range Weighing Format #4: 64mm x 37mm, non-barcode C-0877x / F-0218x Chinese/Japanese/English, Single-Range Weighing Table 9. Label Formats for "No Master Board" BC-3000 scales. Miscellaneous If a scale is to be removed from the system, reset its ROM switch number 2D = 0. Refer to Step A in Setup section above. Rev 2, August 2006 12 BC-3000_ScaletoScale_Comms