for mass spectrometry calibration tools Thermo Scientific Pierce Controls and Standards for Mass Spectrometry



Similar documents
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Advantages of the LTQ Orbitrap for Protein Identification in Complex Digests

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

ProteinPilot Report for ProteinPilot Software

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

SpikeTides TM Peptides for relative and absolute quantification in SRM and MRM Assays

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Mass Spectrometry Based Proteomics

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Overview. Purpose. Methods. Results

Thermo Scientific Mass Spectrometric Immunoassay (MSIA)

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

Correlation of the Mass Spectrometric Analysis of Heat-Treated Glutaraldehyde Preparations to Their 235nm / 280 nm UV Absorbance Ratio

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Henry Shion, Robert Birdsall, Steve Cubbedge, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Mass Spectrometry Signal Calibration for Protein Quantitation

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

TECHNICAL BULLETIN. ProteoMass Peptide & Protein MALDI-MS Calibration Kit. Catalog Number MSCAL1 Store at Room Temperature

LTQ Velos a jeho kombinace s FT-MS Orbitrap Je něco převratně nového v iontových pastech? Petr Verner. ThermoFisher Scientific, Praha

HR/AM Targeted Peptide Quantitation on a Q Exactive MS: A Unique Combination of High Selectivity, Sensitivity and Throughput

LC-MS/MS for Chromatographers

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

Building innovative drug discovery alliances. Evotec Munich. Quantitative Proteomics to Support the Discovery & Development of Targeted Drugs

Separation of Peptides from Enzymatic Digestion on Different Acclaim Columns: A Comparative Study

Monoclonal Antibody Fragment Separation and Characterization Using Size Exclusion Chromatography Coupled with Mass Spectrometry

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

How To Use An Acquity Qda Detector

SUCRALOSE. White to off-white, practically odourless crystalline powder

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

Supplementary Materials and Methods (Metabolomics analysis)

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Laboration 1. Identifiering av proteiner med Mass Spektrometri. Klinisk Kemisk Diagnostik

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Introduction to Proteomics 1.0

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

High-Throughput 3-D Chromatography Through Ion Exchange SPE

NUVISAN Pharma Services

AMD Analysis & Technology AG

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

How To Test For Contamination In Large Volume Water

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

CORESTA RECOMMENDED METHOD N 72

Application Note # LCMS-66 Straightforward N-glycopeptide analysis combining fast ion trap data acquisition with new ProteinScape functionalities

ProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

Electrospray Ion Trap Mass Spectrometry. Introduction

High-Resolution Targeted Quantitation: Biomarker Discovery in a Mouse Transgenic Model of Myopathy

Pesticide Analysis by Mass Spectrometry

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Rapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit

Standard Mixture. TOF/TOF Calibration Mixture. Calibration Mixture 1 (Cal Mix 1, 1:10) Calibration Mixture 1 (Cal Mix 1, 1:100)

Development and Validation of Methods for Chemotherapy Drugs on the New Prelude SPLC LC-MS/MS System

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

EZ-Run Protein Gel Solution. EZ-Run Protein Standards. EZ-Run Gel Staining Solution. Traditional SDS-Page Reagents. Protein Electrophoresis

Quantification of Multiple Therapeutic mabs in Serum Using microlc-esi-q-tof Mass Spectrometry

Aiping Lu. Key Laboratory of System Biology Chinese Academic Society

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

Transcription:

Thermo Scientific Pierce Controls and Standards for Mass Spectrometry calibration tools for mass spectrometry Ensure confidence in instrument performance with Thermo Scientific Pierce Calibration Solutions and Standards.

optimal performance 1 Calibration solutions for mass spectrometers Thermo Scientific Pierce Calibration Solutions for mass spectrometry are ready-to-use liquid formulations that can quickly calibrate Thermo Scientific LC-MS Instrumentation. In addition to calibration solutions, we offer standards for sensitivity assessment or determination of digestion efficiency, or as a control for complex sample analysis.

Selection Guide for Thermo Scientific Calibration Solutions and Standards Thermo Scientific Instrument Pierce LTQ ESI Positive Ion Calibration Solution Pierce LTQ Velos ESI Positive Ion Calibration Solution Pierce ESI Negative Ion Calibration Solution Pierce Triple Quad Calibration Solution Pierce Peptide Retention Time Calibration Mixture Pierce Reserpine Standard for LC-MS Pierce Digestion Indicator for Mass Spec Pierce HeLa Protein Digest Standard Product # 88322 p. 3 88323 p. 4 88324 p. 5 88325 p. 6 88320, 88321 p. 7 88326 p. 8 84841 p. 9 88328, 88329 p. 10 LXQ +++ NR +++ NR +++ ++ +++ +++ LCQ Fleet +++ NR +++ NR +++ ++ +++ +++ LTQ XL ETD +++ NR +++ NR +++ ++ +++ +++ LTQ Velos NR +++ +++ NR +++ +++ +++ +++ LTQ Velos Pro NR +++ +++ NR +++ ++ +++ +++ LTQ rbitrap Discovery +++ NR +++ NR +++ ++ +++ +++ LTQ rbitrap XL +++ NR +++ NR +++ ++ +++ +++ LTQ rbitrap XL ETD +++ NR +++ NR +++ ++ +++ +++ LTQ rbitrap Velos NR +++ +++ NR +++ ++ +++ +++ LTQ rbitrap Velos Pro NR +++ +++ NR +++ ++ +++ +++ MALDI LTQ XL NR NR NR NR +++ NR +++ +++ MALDI LTQ rbitrap XL NR NR NR NR +++ NR +++ +++ rbitrap ELITE NR +++ +++ NR +++ ++ +++ +++ rbitrap Fusion Tribrid NR +++ +++ NR +++ +++ +++ +++ Exactive +++ NR +++ NR +++ + +++ +++ Exactive Plus NR +++ +++ NR +++ + +++ +++ Q Exactive/Q Exactive Plus NR +++ +++ NR +++ + +++ +++ LTQ FT Ultra +++ NR +++ NR +++ ++ +++ +++ TSQ Access Max NR NR NR +++ +++ +++ +++ +++ TSQ Quantum Ultra NR NR NR +++ +++ +++ +++ +++ TSQ Vantage NR NR NR +++ +++ +++ +++ +++ TSQ Endura NR NR NR +++ +++ +++ +++ +++ TSQ Quantiva NR NR NR +++ +++ +++ +++ +++ +++ = Highly recommended ++ = Recommended + = Can be used, but not recommended NR = Not recommended 2

calibration solutions Thermo Scientific Pierce LTQ ESI Positive Ion Calibration Solution spectra. Formulation: Caffeine (20µg/mL), MRFA (1µg/mL) and Ultramark 1621 (0.001%) in an aqueous solution of acetonitrile (50%), methanol (25%) and acetic acid (1%). Thermo Scientific Pierce LTQ ESI Positive Ion Calibration Solution Use to calibrate Thermo Scientific LTQ Series, the LTQ rbitrap Series, the LXQ, LCQ FLEET and the Exactive (classic) Mass Spectrometer instruments. The Thermo Scientific Pierce LTQ ESI Positive Ion Calibration Solution is a mixture of highly purified ionizable molecules specifically designed for positive mode calibration of Thermo Scientific Ion Trap and rbitrap instruments. The Pierce LTQ ESI Positive Ion Calibration Solution is a ready-to-use liquid formulation ideal for quickly performing the routine calibration required to maintain the robust performance of Thermo Scientific Mass Spectrometers. The LTQ ESI Positive Ion Calibration Solution is manufactured at an IS 9001 facility and each lot is quality controlled with strict specifications. The stable solution is provided in a leak-proof, high-purity PTFE bottle. Strong peaks mixture of caffeine, MRFA and Ultramark 1621 in an acetonitrile/methanol/acetic solution Ready to use load the mass reference standard into a syringe and inject into the instrument High purity mass spectrometry-grade reagents in a non-leachable container Stable store at room temperature for more than one year rdering Information Pkg. Size 88322 Pierce LTQ ESI Positive Ion Calibration Solution 10mL Sufficient for 10 to 20 calibrations 3

Thermo Scientific Pierce LTQ ESI Positive Ion Calibration Solution spectra. Formulation: Caffeine (20µg/mL), MRFA (1µg/mL) and Ultramark 1621 (0.001%) in an aqueous solution of acetonitrile (50%), methanol (25%) and acetic acid (1%). Thermo Scientific Pierce LTQ Velos ESI Positive Ion Calibration Solution Use to calibrate the Thermo Scientific LTQ Velos Series and LTQ rbitrap Velos, Q Exactive Series and Exactive Plus Mass Spectrometer instruments. The Thermo Scientific Pierce LTQ Velos ESI Positive Ion Calibration Solution is a mixture of highly purified ionizable molecules designed for positive mode calibration of Thermo Scientific LTQ Velos Series Mass Spectrometer instruments. The Pierce LTQ Velos ESI Positive Ion Calibration Solution is a ready-to-use liquid formulation ideal for quickly performing the routine calibration required to maintain the robust performance of Thermo Scientific Mass Spectrometers. The LTQ Velos ESI Positive Ion Calibration Solution is manufactured at an IS 9001 facility and each lot is quality controlled with strict specifications. The stable solution is provided in a leak-proof, high-purity PTFE bottle. Strong peaks mixture of caffeine, MRFA, Ultramark 1621 and n-butylamine in an acetonitrile/methanol/acetic solution Ready to use load the mass reference standard into a syringe and inject into the instrument High purity mass spectrometry-grade reagents in a non-leachable container Stable store at room temperature for more than one year rdering Information 88323 Pierce LTQ Velos ESI Positive Ion Calibration Solution Sufficient for 10 to 20 calibrations Pkg. Size 10mL 4

calibration solutions Thermo Scientific Pierce ESI Negative Calibration Solution spectra. Formulation: sodium dodecyl sulfate (2.9µg/mL),sodium taurocholate (5.4µg/mL) and Ultramark 1621 (0.001%) in an aqueous solution of acetonitrile (50%), methanol (25%) and acetic acid (1%). Thermo Scientific Pierce ESI Negative Ion Calibration Solution Use to calibrate Thermo Scientific LTQ Series, LTQ Velos Series, the LTQ rbitrap Series and Exactive Mass Spectrometer instruments. The Thermo Scientific Pierce ESI Negative Ion Calibration Solution is a mixture of highly purified ionizable molecules designed for negative mode calibration of Thermo Scientific LTQ Series Mass Spectrometer instruments. Strong peaks mixture of SDS, sodium taurocholate and Ultramark 1621 in an acetonitrile/methanol/acetic solution Ready to use load the mass reference standard into a syringe and inject into the instrument High purity mass spectrometry-grade reagents in a non-leachable container Stable store at room temperature for more than one year The Pierce ESI Negative Ion Calibration Solution is a ready-to-use liquid formulation ideal for quickly performing the routine calibration required to maintain the robust performance of Thermo Scientific Mass Spectrometers. The ESI Negative Ion Calibration Solution is manufactured at an IS 9001 facility and each lot is quality controlled with strict specifications. The stable solution is provided in a leak-proof, high-purity PTFE bottle. rdering Information 88324 Pierce ESI Negative Ion Calibration Solution Sufficient for 10 to 20 calibrations Pkg. Size 10mL 5

Thermo Scientific Pierce Triple Quadrupole Calibration Solution. Formulation: 25µM Tyr 1, 25µM Tyr 3 and 25µM Tyr 6, in an aqueous of methanol (50%) and formic acid (0.1%). Thermo Scientific Pierce Triple Quadrupole Calibration Solution Use to calibrate Thermo Scientific TSQ Quantum, TSQ Discovery, TSQ Quantum Ultra, TSQ Quantum Access, TSQ Vantage, TSQ Endura and TSQ Quantiva Series Mass Spectrometer instruments. Strong peaks mixture of three tyrosine polymers in methanol/formic acid solution Ready to use load the reference standard into a syringe and inject into the instrument High purity mass spectrometry-grade reagents in a non-leachable container Stable store at 2 to 8 C for more than one year The Thermo Scientific Pierce Triple Quadrupole Calibration Solution is a mixture of high purity, ionizable components specifically designed for positive mode calibration of Thermo Scientific Triple Stage Quadrupole instruments. The Pierce Triple Quadrupole Calibration Solution is a ready-to-use liquid formulation ideal for quickly performing the required routine calibration to maintain the robust performance of Thermo Scientific Mass Spectrometers. The Triple Quadrupole Calibration Solution is manufactured at an IS 9001 facility and each lot is quality controlled with strict specifications. The stable solution is provided in a leak-proof, high-purity PTFE bottle. rdering Information 88325 Pierce Triple Quadrupole Calibration Solution Sufficient for 10 to 20 calibrations Pkg. Size 10mL 6

calibration solutions Thermo Scientific Pierce Peptide Retention Time Calibration Mixture The prediction of peptide retention time is a tool to assess chromatographic performance and to assist in the development of multiplexed, high-throughput mass spectrometric assays. Thermo Scientific Pierce Peptide Retention Time Calibration Mixture and Thermo Scientific Pinpoint Software can be used to predict peptide retention time from sequence alone or to streamline the transition from qualitative protein discovery results to the development of targeted mass spectrometry (MS) assays on Thermo Scientific Triple Quadrupole, rbitrap, Exactive and Ion Trap Mass Spectrometers. The Pierce Peptide Retention Time Calibration Mixture can be used for optimization and regular assessment of chromatographic performance and for rapid development of multiplexed, scheduled targeted MS assays for the quantification of dozens to hundreds of peptide targets per run. Applications: Assessment of chromatography and MS instrument performance Prediction of peptide retention across multiple instrument platforms Prediction of peptide retention time from sequence using calculated hydrophobicity factor ptimization of scheduled MS acquisition windows for improved quantification and increased multiplexing Internal standard to normalize for variation in retention times and peak intensities between runs A. The Pierce Peptide Retention Time Calibration Mixture contains 15 synthetic heavy peptides mixed at an equimolar ratio that elute across the chromatographic gradient. The peptide sequences and chromatographic results are used to assess LC performance. In addition, the observed retention times and hydrophobicity factors (HF) for these calibrants are fit to a linear equation to determine the slope of the retention time/hf relationship. This equation and the HF of uncharacterized peptides are then used to predict retention time. Thermo Scientific Pierce Peptide Retention Time Calibration mixture components and properties. The peptide sequences, peptide masses and chromatographic behavior of each component of the Pierce Peptide Retention Time Calibration Mixture are given below. The position and identity of the heavy isotope-labeled amino acid in each sequence is indicated in bold. Peptide Sequence Mass Hydrophobicity Factor (HF) 1 SSAAPPPPPR 985.5220 7.56 2 GISNEGQNASIK 1224.6189 15.50 3 HVLTSIGEK 990.5589 15.52 4 DIPVPKPK 900.5524 17.65 5 IGDYAGIK 843.4582 19.15 6 TASEFDSAIAQDK 1389.6503 25.88 7 SAAGAFGPELSR 1171.5861 25.24 8 ELGQSGVDTYLQTK 1545.7766 28.37 9 GLILVGGYGTR 1114.6374 32.18 10 GILFVGSGVSGGEEGAR 1600.8084 34.50 11 SFANQPLEVVYSK 1488.7704 34.96 12 LTILEELR 995.5890 37.30 13 NGFILDGFPR 1144.5905 40.42 14 ELASGLSFPVGFK 1358.7326 41.18 15 LSSEAPALFQFDLK 1572.8279 46.66 Chromatographic analysis of the Thermo Scientific Pierce Peptide Retention Time Calibration Mixture. A. The Pierce Peptide Retention Time Calibration Mixture (250fmoles) was analyzed in duplicate on a Thermo Scientific LTQ XL rbitrap Mass Spectrometer using a self-packed column (75µm x 20cm) containing Magic C18 (Michrom Bioresources) and using a 0.25% per minute gradient of Buffer A (0.1% formic acid) and Buffer B (0.1% formic acid/99.9 % acetonitrile) at 300nL per minute. B. The Pierce Retention Time Calibration Mixture was also analyzed on a Thermo Scientific TSQ Vantage Mass Spectrometer using a Thermo Scientific Hypersil GLD C18 column (1.0 x 150mm, Product # 25005-150165) with a 1.0% per minute gradient at 120µL per minute. Numbered peaks correspond to the calibrant peptides described above. B. rdering Information 88320 Pierce Peptide Retention Time Calibration Mixture, 0.5pmol/µL 88321 Pierce Peptide Retention Time Calibration Mixture, 5pmol/µL Pkg. Size 50µL 200µL 7

standards N H H N H H Reserpine MW 608.68 Exact Mass: 608.27 Chemical structure of reserpine. The Pierce Reserpine Standard for LC-MS consists of high-purity reserpine at 100pg/μL in 50% isopropyl alcohol. Thermo Scientific Pierce Reserpine Standard for LC-MS Thermo Scientific Pierce Reserpine Standard for LC-MS is a precise concentration of reserpine specifically designed for performance evaluation of mass spectrometers, including the Thermo Scientific Ion Trap and TSQ Series of instruments. The Pierce Reserpine Standard for LC-MS is a pre-diluted liquid formulation that is ideal for performing installation tests of Thermo Scientific and other manufacturers mass spectrometers. The standard is provided at a concentration of 100pg/μL in 50% isopropyl alcohol and requires minimal additional dilutions. The product is provided as a pack of 5 x 1mL glass amber vials with PTFE-lined screw caps. The Pierce Reserpine Standard for LC-MS is manufactured at an IS 9001 facility and each lot is quality controlled with strict specifications. Convenient provided at a concentration of 100pg/μL in 50% isopropyl alcohol, requiring minimal additional dilutions to reach target concentration for injection Safe handling unlike glass ampules, cap can be easily removed and replaced when withdrawing solution High purity mass spectrometry-grade reagent in non-leachable screw-cap vials Stable store at 4 C for up to one year V3374_SENSITIVITY_MeH_100_100 70%MeH/30%Water (0.05% formic acid) RT: 0.00-4.65 Relative Abundance 100 80 60 40 20 RT: 1.04 AH: 2015 RT: 2.05 AH: 2085 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Time (min) V3374_SENSITIVITY_MeH_100_100 #114 RT: 0.61 AV: 1 NL: 1.13 T: + c ESI SRM ms2 609.320 [195.099-195.101, 448.199-448.201] Relative Abundance 100 90 80 70 60 50 40 30 20 10 0 195.099 195.10 195.100 195.101 m/z 448.199 RT: 3.09 AH: 1997 5µL of 100fg/µL reserpine 448.20 448.200 448.201 m/z Example selected reaction monitoring (SRM) of 500fg reserpine on a Thermo Scientific Vantage triple quadrupole mass spectrometer. Chromatogram of three 5μL loop injections of 100fg/μL Pierce Reserpine on a Hypersil GLD aq 2.1x20mm Javelin column with isocratic 300μL/min flow of 70% methanol: 30% water: 0.05% formic acid (upper panel).the SRM transitions monitored were 609.3-195.1 and 609.3-448.2 m/z with a 0.2 FWHM Q1 peak width (lower panel). rdering Information Product # Description 88326 Pierce Reserpine Standard for LC-MS Sufficient for 5 to 500 injections Pkg. Size 5 x 1mL 8

standards Thermo Scientific Pierce Digestion Indicator Thermo Scientific Pierce Digestion Indicator is a unique, non-mammalian protein (26kDa) that can be spiked into cell lysates and carried through the sample preparation procedure, resulting in five distinct peptides that can be quantified. The Digestion Indicator is provided as a frozen liquid (10µg) and an aliquot of 0.5µg is recommended per 100µg sample of lysate. The Pierce Digestion Indicator is also provided as a component of the Thermo Scientific Pierce Mass Spec Sample Prep Kit for Cultured Cells (Product # 84840). Non-mammalian Pierce Digestion Indicator peptides can be easily distinguished from endogenous mammalian peptides Ready to use just thaw and spike into lysate Validated contains 5 distinct peptides that can be quantitated to assess digestion efficiency The Pierce Digestion Indicator serves as an internal digestion control standard protein to assure protocol performance and to quantify sample preparation processing and digestion efficiency across samples. The properties of the signature peptides following digestion are indicated in Table 1. To test the reproducibility of the Pierce Mass Spec Sample Prep Kit for Cultured Cells (Product # 84840), triplicate samples of a HeLa cell culture were processed and analyzed using the Pierce Digestion Indicator protocol by spiking the Digestion Indicator into each lysate after the initial lysis step. The samples were analyzed by LC-MS/MS on a Thermo Scientific Velos Pro Ion Trap Mass Spectrometer. Digestion indicator peptides were quantified with Thermo Scientific Pinpoint 1.2 software, which is pre-programmed to quantify the Pierce Digestion Indicator peptides and MS 2 transitions. The coefficients of variation (CV) for replicates of the five peptides were 6-16% (Table 2). Table 1. Properties of the five Thermo Scientific Pierce Digestion Indicator peptide sequences. Digestion Indicator Peptide Sequence bserved Mass/Charge bserved Charge Hydrophobicity Factor ITGTLNGVEFELVGGGEGTPEQGR 1209.1007 +2 40.59 VMGTGFPEDSVIFTDK 871.9189 +2 40.24 DGGYYSSVVDSHMHFK 610.2701 +3 27.24 SAIHPSILQNGGPMFAFR 648.3367 +3 42.42 VEEDHSNTELGIVEYQHAFK 587.0315 +4 35.13 Table 2. Digestion indicator peptides and example assessment of reproducibility. Sequences of the five peptides that result from the Thermo Scientific Pierce Digestion Indicator, and coefficients of variation (CV) for triplicate samples processed using the product protocol. Digestion Indicator Peptide Sequence bserved Mass/Charge Coefficients of Variation (CV) ITGTLNGVEFELVGGGEGTPEQGR 1209.1010 16 VMGTGFPEDSVIFTDK 871.9189 13 DGGYYSSVVDSHMHFK 610.2701 6 SAIHPSILQNGGPMFAFR 648.3367 13 VEEDHSNTELGIVEYQHAFK 587.0315 13 rdering Information Pkg. Size 84841 Pierce Digestion Indicator for Mass Spectrometry 10µg Sufficient for production of five signature peptides upon digestion for mass spectrometry 9

RT: 0.00-120.00 100 58.60 Relative Abundance 90 80 70 60 50 40 30 55.11 29.95 24.39 30.67 47.61 49.60 74.50 18.93 37.37 61.96 43.84 6.02 18.17 64.56 87.85 6.57 20 17.59 78.80 94.68 82.74 97.86 10 98.73 104.23 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Time (min) Thermo Scientific Pierce HeLa Protein Digest Standard Superior-quality complex mammalian protein digest standard. The Thermo Scientific Pierce HeLa Protein Digest Standard is a highly validated mammalian protein digest that may be used as a quality control sample for MS analysis of complex proteomic samples. Positive control sample complex mammalian proteome sample protein digest (> 15,000 proteins) High digestion efficiency less than 10% missed cleavages using trypsin and LysC Superior peptide quality less than 10% methionine oxidation and less than 10% lysine carbamylation Rigorously tested high-quality, efficient protein digest with lot-to-lot digest uniformity Stable provided in a stable, lyophilized format The Pierce HeLa Protein Digest Standard is a lyophilized tryptic peptide mixture that can be used as a quality control standard for liquid chromatography (LC) separation, MS method development and MS performance benchmarking. The digest is specifically formulated for LC/MS experiments and does not contain salts or detergents. Using the digest standard routinely before analysis of complex samples makes it possible to monitor and normalize LC/MS performance between samples and over time. Thermo Scientific Pierce HeLa Digest Standard base peak chromatogram. Chromatogram of 200ng Pierce HeLa Protein Digest Standard separated using a Thermo Scientific Acclaim PepMap 100 3µm x 75µm x 15cm column (Product # 160321) with a 2-35% gradient (A: 0.1% FA in water, B: 0.1% FA in 100% acetonitrile) at 300nL/min for 120 minutes and detected on a Thermo Scientific LTQ rbitrap XL Mass Spectrometer. Thermo Scientific Pierce HeLa Protein Digest Standard quality testing specifications. Analysis Specification UV Absorbance A 280 = 1.0 -/+ 0.1 LC/MS Chromatogram Reference Peptide Area LC/MS chromatogram conforms to reference Ratio of peptide area to reference = 0.75-1.25 *Peptide Missed Cleavage Tryptic peptide missed cleavage 10% *Peptide Alkylation Cysteine carbamidomethyl modification 98% *Peptide xidation Methionine oxidation 10% *ther Peptide Modification Carbamylation < 10% * Peptide missed cleavage, alkylation, oxidation and modification determined by Preview Software (Protein Metrics) using a human protein Swiss-Prot database. rdering Information Pkg. Size 88328 Pierce HeLa Protein Digest Standard 20μg 88329 Pierce HeLa Protein Digest Standard 5 x 20μg The protein digest is derived from a well-established adenocarcinoma (HeLa) reference cell line, which expresses over 15,000 proteins with relevant posttranslational modifications making it an ideal standard for complex proteome MS applications. The protein lysate has been digested with both LysC and trypsin to reduce tryptic missed cleavages and improve protein sequence coverage. Moreover, unlike other commercially available protein digests for MS, the Pierce HeLa Protein Digest Standard must meet stringent quality testing specifications including peptide quality, digestion efficiency and lot-to-lot digest uniformity. 10

thermoscientific.com/pierce thermoscientific.com/pierce 2015 Thermo Fisher Scientific Inc. All rights reserved. These products are supplied for laboratory or manufacturing applications only. Facebook is a trademark of Facebook, Inc. Ultramark is a trademark of Lancaster Synthesis. Magic is a trademark of Bruker. Preview is a trademark of Protein Metrics. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Africa/Belgium/Europe/Middle East +32 53 85 71 84 France 0 800 50 82 15 Germany 0228 9125650 Netherlands 076 50 31 880 Switzerland 0800 56 31 40 UK 0800 252 185 1602867 01/15 Printed in the U.S. Email: perbio.euromarketing@thermofisher.com thermoscientific.com/pierce For other regions, visit thermoscientific.com/piercedistributors USA +815-968-0747 or +800-874-3723 Customer Assistance E-mail:Pierce.CS@thermofisher.com thermoscientific.com/pierce